Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Breast Cancer Res ; 26(1): 22, 2024 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-38317255

RESUMO

PURPOSE: One major risk factor for breast cancer is high mammographic density. It has been estimated that dense breast tissue contributes to ~ 30% of all breast cancer. Prevention targeting dense breast tissue has the potential to improve breast cancer mortality and morbidity. Anti-estrogens, which may be associated with severe side-effects, can be used for prevention of breast cancer in women with high risk of the disease per se. However, no preventive therapy targeting dense breasts is currently available. Inflammation is a hallmark of cancer. Although the biological mechanisms involved in the increased risk of cancer in dense breasts is not yet fully understood, high mammographic density has been associated with increased inflammation. We investigated whether low-dose acetylsalicylic acid (ASA) affects local breast tissue inflammation and/or structural and dynamic changes in dense breasts. METHODS: Postmenopausal women with mammographic dense breasts on their regular mammography screen were identified. A total of 53 women were randomized to receive ASA 160 mg/day or no treatment for 6 months. Magnetic resonance imaging (MRI) was performed before and after 6 months for a sophisticated and continuous measure breast density by calculating lean tissue fraction (LTF). Additionally, dynamic quantifications including tissue perfusion were performed. Microdialysis for sampling of proteins in vivo from breasts and abdominal subcutaneous fat, as a measure of systemic effects, before and after 6 months were performed. A panel of 92 inflammatory proteins were quantified in the microdialysates using proximity extension assay. RESULTS: After correction for false discovery rate, 20 of the 92 inflammatory proteins were significantly decreased in breast tissue after ASA treatment, whereas no systemic effects were detected. In the no-treatment group, protein levels were unaffected. Breast density, measured by LTF on MRI, were unaffected in both groups. ASA significantly decreased the perfusion rate. The perfusion rate correlated positively with local breast tissue concentration of VEGF. CONCLUSIONS: ASA may shape the local breast tissue microenvironment into an anti-tumorigenic state. Trials investigating the effects of low-dose ASA and risk of primary breast cancer among postmenopausal women with maintained high mammographic density are warranted. Trial registration EudraCT: 2017-000317-22.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Mamografia/métodos , Densidade da Mama , Aspirina/efeitos adversos , Pós-Menopausa , Inflamação/tratamento farmacológico , Microambiente Tumoral
2.
Eur Radiol ; 34(9): 5989-5999, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38459346

RESUMO

OBJECTIVES: To evaluate the diagnostic performance of ultrasound guided attenuation parameter (UGAP) for evaluating liver fat content with different probe forces and body positions, in relation to sex, and compared with proton density fat fraction (PDFF). METHODS: We prospectively enrolled a metabolic dysfunction-associated steatotic liver disease (MASLD) cohort that underwent UGAP and PDFF in the autumn of 2022. Mean UGAP values were obtained in supine and 30° left decubitus body position with normal 4 N and increased 30 N probe force. The diagnostic performance was evaluated by the area under the receiver operating characteristic curve (AUC). RESULTS: Among 60 individuals (mean age 52.9 years, SD 12.9; 30 men), we found the best diagnostic performance with increased probe force in 30° left decubitus position (AUC 0.90; 95% CI 0.82-0.98) with a cut-off of 0.58 dB/cm/MHz. For men, the best performance was in supine (AUC 0.91; 95% CI 0.81-1.00) with a cut-off of 0.60 dB/cm/MHz, and for women, 30° left decubitus position (AUC 0.93; 95% CI 0.83-1.00), with a cut-off 0.56 dB/cm/MHz, and increased 30 N probe force for both genders. No difference was in the mean UGAP value when altering body position. UGAP showed good to excellent intra-reproducibility (Intra-class correlation 0.872; 95% CI 0.794-0.921). CONCLUSION: UGAP provides excellent diagnostic performance to detect liver fat content in metabolic dysfunction-associated steatotic liver diseases, with good to excellent intra-reproducibility. Regardless of sex, the highest diagnostic accuracy is achieved with increased probe force with men in supine and women in 30° left decubitus position, yielding different cut-offs. CLINICAL RELEVANCE STATEMENT: The ultrasound method ultrasound-guided attenuation parameter shows excellent diagnostic accuracy and performs with good to excellent reproducibility. There is a possibility to alter body position and increase probe pressure, and different performances for men and women should be considered for the highest accuracy. KEY POINTS: • There is a possibility to alter body position when performing the ultrasound method ultrasound-guided attenuation parameter. • Increase probe pressure for the highest accuracy. • Different performances for men and women should be considered.


Assuntos
Ultrassonografia , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Ultrassonografia/métodos , Posicionamento do Paciente/métodos , Fígado Gorduroso/diagnóstico por imagem , Pressão , Reprodutibilidade dos Testes , Adulto , Fatores Sexuais , Fígado/diagnóstico por imagem , Idoso
3.
Eur Radiol ; 2024 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-39136707

RESUMO

OBJECTIVES: The use of magnetic resonance imaging (MRI) is safe from a long-term perspective since there are no known cumulative risks for patients or personnel. However, the technique comes with several acute risks associated with the powerful electromagnetic fields that are necessary to produce medical images. These risks include, among other things, a projectile hazard, loud noise, and the risk of heating. Safe use of MRI requires knowledge about the different hazards related to MRI and organizational structured work including the implementation of routines describing a safe workflow from the referral of a patient to the signed report. In this article, the risks associated with MRI are described along with suggestions for how each risk can be minimized or eliminated. CONCLUSION: The aim of this article is to provide support for the development of, and compliance with, MRI safety routines, and to work with the technique in a safe way. The scope of this treatise does not cover specific details of implant safety, however, the physical principles described can be applied to the risk assessment of implants. KEY POINTS: Establish whether any MR contraindications apply to the patient. Evaluate means to deal with identified risks for both patients and personnel. It is imperative to always perform and document a risk-benefit assessment.

4.
Cardiovasc Diabetol ; 22(1): 261, 2023 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-37759237

RESUMO

BACKGROUND: Patients with type 2 diabetes have an increased risk of death and cardiovascular events and people with diabetes or prediabetes have been found to have increased atherosclerotic burden in the coronary and carotid arteries. This study will estimate the cross-sectional prevalence of atherosclerosis in the coronary and carotid arteries in individuals with prediabetes and diabetes, compared with normoglycaemic individuals in a large population-based cohort. METHODS: The 30,154 study participants, 50-64 years, were categorized according to their fasting glycaemic status or self-reported data as normoglycaemic, prediabetes, and previously undetected or known diabetes. Prevalence of affected coronary artery segments, severity of stenosis and coronary artery calcium score (CACS) were determined by coronary computed tomography angiography. Total atherosclerotic burden was assessed in the 11 clinically most relevant segments using the Segment Involvement Score and as the presence of any coronary atherosclerosis. The presence of atherosclerotic plaque in the carotid arteries was determined by ultrasound examination. RESULTS: Study participants with prediabetes (n = 4804, 16.0%) or diabetes (n = 2282, 7.6%) had greater coronary artery plaque burden, more coronary stenosis and higher CACS than normoglycaemic participants (all, p < 0.01). Among male participants with diabetes 35.3% had CACS ≥ 100 compared to 16.1% among normoglycaemic participants. For women, the corresponding figures were 8.9% vs 6.1%. The prevalence of atherosclerosis in the coronary arteries was higher in participants with previously undetected diabetes than prediabetes, but lower than in patients with known diabetes. The prevalence of any plaque in the carotid arteries was higher in participants with prediabetes or diabetes than in normoglycaemic participants. CONCLUSIONS: In this large population-based cohort of currently asymptomatic people, the atherosclerotic burden in the coronary and carotid arteries increased with increasing degree of dysglycaemia. The finding that the atherosclerotic burden in the coronary arteries in the undetected diabetes category was midway between the prediabetes category and patients with known diabetes may have implications for screening strategies and tailored prevention interventions for people with dysglycaemia in the future.


Assuntos
Aterosclerose , Diabetes Mellitus Tipo 2 , Placa Aterosclerótica , Estado Pré-Diabético , Humanos , Feminino , Masculino , Estado Pré-Diabético/diagnóstico , Estado Pré-Diabético/epidemiologia , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/epidemiologia , Estudos Transversais , Prevalência , Suécia/epidemiologia
5.
Br J Cancer ; 127(11): 2025-2033, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36138072

RESUMO

BACKGROUND: High mammographic density is an independent risk factor for breast cancer by poorly understood molecular mechanisms. Women with dense breasts often undergo conventional magnetic resonance imaging (MRI) despite its limited specificity, which may be increased by diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) and contrast. How these modalities are affected by breast density per se and their association with the local microenvironment are undetermined. METHODS: Healthy postmenopausal women attending mammography screen with extremely dense or entirely fatty breasts underwent multiparametric MRI for analyses of lean tissue fraction (LTF), ADC and perfusion dynamics. Microdialysis was used for extracellular proteomics in situ. RESULTS: Significantly increased LTF and ADC and delayed perfusion were detected in dense breasts. In total, 270 proteins were quantified, whereof 124 related to inflammation, angiogenesis, and cellular growth were significantly upregulated in dense breasts. Most of these correlated significantly with LTF, ADC and the perfusion data. CONCLUSIONS: ADC and perfusion characteristics depend on breast density, which should be considered during the implementation of thresholds for malignant lesions. Dense and nondense breasts are two essentially different biological entities, with a pro-tumorigenic microenvironment in dense breasts. Our data reveal several novel pathways that may be explored for breast cancer prevention strategies.


Assuntos
Neoplasias da Mama , Imageamento por Ressonância Magnética Multiparamétrica , Feminino , Humanos , Densidade da Mama , Mamografia/métodos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Carcinogênese , Biomarcadores , Microambiente Tumoral
6.
Eur Radiol ; 32(1): 477-488, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34286376

RESUMO

OBJECTIVES: The purpose of this study was to develop a procedure to investigate the occurrence, character and causes of magnetic resonance (MR) imaging incidents. METHODS: A semi-structured questionnaire was developed containing details such as safety zones, examination complexity, staff MR knowledge, staff categories, and implementation of EU directive 2013/35. We focused on formally reported incidents that had occurred during 2014-2019, and unreported incidents during one year. Thirteen clinical MR units were visited, and the managing radiographer was interviewed. Open questions were analysed using conventionally adopted content analysis. RESULTS: Thirty-seven written reports for 5 years and an additional 12 oral reports for 1 year were analysed. Only 38% of the incidents were reported formally. Some of these incidents were catastrophic. Negative correlations were observed between the number of annual incidents (per scanner) and staff MR knowledge (Spearman's rho - 0.41, p < 0.05) as well as the number of MR physicists per scanner (- 0.48, p < 0.05). It was notable that only half of the sites had implemented the EU directive. Quotes like 'Burns are to be expected in MR' and not even knowing the name of the incident reporting system suggested an inadequate safety culture. Finally, there was a desire among staff for MR safety education. CONCLUSIONS: MR-related incidents were greatly underreported, and some incidents could have had catastrophic outcomes. There is a great desire among radiographers to enhance the safety culture, but to achieve this, much more accessible education is required, as well as focused involvement of the management of the operations. KEY POINTS: • Only one in three magnetic resonance-related incidents were reported. • Several magnetic resonance incidents could have led to catastrophic consequences. • Much increased knowledge about magnetic resonance safety is needed by radiologists and radiographers.


Assuntos
Erros Médicos , Gestão de Riscos , Humanos , Imageamento por Ressonância Magnética , Gestão da Segurança , Inquéritos e Questionários
7.
MAGMA ; 35(5): 711-718, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34958438

RESUMO

OBJECTIVE: To evaluate systolic flow-sensitive alternating inversion recovery (FAIR) during rest and exercise stress using 2RR (two cardiac cycles) or 1RR intervals between inversion pulse and imaging. MATERIALS AND METHODS: 1RR and 2RR FAIR was implemented on a 3T scanner. Ten healthy subjects were scanned during rest and stress. Stress was performed using an in-bore ergometer. Heart rate, mean myocardial blood flow (MBF) and temporal signal-to-noise ratio (TSNR) were compared using paired t tests. RESULTS: Mean heart rate during stress was higher than rest for 1RR FAIR (85.8 ± 13.7 bpm vs 63.3 ± 11.1 bpm; p < 0.01) and 2RR FAIR (83.8 ± 14.2 bpm vs 63.1 ± 10.6 bpm; p < 0.01). Mean stress MBF was higher than rest for 1RR FAIR (2.97 ± 0.76 ml/g/min vs 1.43 ± 0.6 ml/g/min; p < 0.01) and 2RR FAIR (2.8 ± 0.96 ml/g/min vs 1.22 ± 0.59 ml/g/min; p < 0.01). Resting mean MBF was higher for 1RR FAIR than 2RR FAIR (p < 0.05), but not during stress. TSNR was lower for stress compared to rest for 1RR FAIR (4.52 ± 2.54 vs 10.12 ± 3.69; p < 0.01) and 2RR FAIR (7.36 ± 3.78 vs 12.41 ± 5.12; p < 0.01). 2RR FAIR TSNR was higher than 1RR FAIR for rest (p < 0.05) and stress (p < 0.001). DISCUSSION: We have demonstrated feasibility of systolic FAIR in rest and exercise stress. 2RR delay systolic FAIR enables non-contrast perfusion assessment during stress with relatively high TSNR.


Assuntos
Imagem de Perfusão do Miocárdio , Circulação Coronária/fisiologia , Coração , Humanos , Imagem de Perfusão do Miocárdio/métodos , Perfusão , Razão Sinal-Ruído
8.
NMR Biomed ; 34(2): e4436, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33150707

RESUMO

Quantitative myocardial perfusion can be achieved without contrast agents using flow-sensitive alternating inversion recovery (FAIR) arterial spin labeling. However, FAIR has an intrinsically low sensitivity, which may be improved by mitigating the effects of physiological noise or by increasing the area of artifact-free myocardium. The aim of this study was to investigate if systolic FAIR may increase the amount of analyzable myocardium compared with diastolic FAIR and its effect on physiological noise. Furthermore, we compare parallel imaging acceleration with a factor of 2 with compressed sensing acceleration with a factor of 3 for systolic FAIR. Twelve healthy subjects were scanned during rest on a 3 T scanner using diastolic FAIR with parallel imaging factor 2 (FAIR-PI2D ), systolic FAIR with the same acceleration (FAIR-PI2S ) and systolic FAIR with compressed sensing factor 3 (FAIR-CS3S ). The number of analyzable pixels in the myocardium, temporal signal-to-noise ratio (TSNR) and mean myocardial blood flow (MBF) were calculated for all methods. The number of analyzable pixels using FAIR-CS3S (663 ± 55) and FAIR-PI2S (671 ± 58) was significantly higher than for FAIR-PI2D (507 ± 82; P = .001 for both), while there was no significant difference between FAIR-PI2S and FAIR-CS3S . The mean TSNR of the midventricular slice for FAIR-PI2D was 11.4 ± 3.9, similar to that of FAIR-CS3S, which was 11.0 ± 3.3, both considerably higher than for FAIR-PI2S, which was 8.4 ± 3.1 (P < .05 for both). Mean MBF was similar for all three methods. The use of compressed sensing accelerated systolic FAIR benefits from an increased number of analyzable myocardial pixels compared with diastolic FAIR without suffering from a TSNR penalty, unlike systolic FAIR with parallel imaging acceleration.


Assuntos
Angiografia/métodos , Vasos Coronários/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador , Adulto , Compressão de Dados , Diástole , Feminino , Frequência Cardíaca , Hemorreologia , Humanos , Masculino , Descanso , Marcadores de Spin , Sístole
9.
J Cardiovasc Magn Reson ; 22(1): 83, 2020 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-33280612

RESUMO

BACKGROUND: Several cardiovascular magnetic resonance (CMR) techniques can measure myocardial strain and torsion with high accuracy. The purpose of this study was to compare displacement encoding with stimulated echoes (DENSE), tagging and feature tracking (FT) for measuring circumferential and radial myocardial strain and myocardial torsion in order to assess myocardial function and infarct scar burden both at a global and at a segmental level. METHOD: 116 patients with a high likelihood of coronary artery disease (European SCORE > 15%) underwent CMR examination including cine images, tagging, DENSE and late gadolinium enhancement (LGE) in the short axis direction. In total, 97 patients had signs of myocardial disease and 19 had no abnormalities in terms of left ventricular (LV) wall mass index, LV ejection fraction, wall motion, LGE or a history of myocardial infarction. Thirty-four patients had myocardial infarct scar with a transmural LGE extent (transmurality) that exceeded 50% of the wall thickness in at least one segment. Global circumferential strain (GCS) and global radial strain (GRS) was analyzed using FT of cine loops, deformation of tag lines or DENSE displacement. RESULTS: DENSE and tagging both showed high sensitivity (82% and 71%) at a specificity of 80% for the detection of segments with > 50% LGE transmurality, and receiver operating characteristics (ROC) analysis showed significantly higher area under the curve-values (AUC) for DENSE (0.87) than for tagging (0.83, p < 0.001) and FT (0.66, p = 0.003). GCS correlated with global LGE when determined with DENSE (r = 0.41), tagging (r = 0.37) and FT (r = 0.15). GRS had a low but significant negative correlation with LGE; DENSE r = - 0.10, FT r = - 0.07 and tagging r = - 0.16. Torsion from DENSE and tagging had a weak correlation (- 0.20 and - 0.22 respectively) with global LGE. CONCLUSION: Circumferential strain from DENSE detected segments with > 50% scar with a higher AUC than strain determined from tagging and FT at a segmental level. GCS and torsion computed from DENSE and tagging showed similar correlation with global scar size, while when computed from FT, the correlation was lower.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Infarto do Miocárdio/diagnóstico por imagem , Miocárdio/patologia , Volume Sistólico , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Torção Mecânica
10.
Magn Reson Med ; 78(1): 285-296, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27510300

RESUMO

PURPOSE: The aim of this work was to quantify the extent of lipid-rich necrotic core (LRNC) and intraplaque hemorrhage (IPH) in atherosclerotic plaques. METHODS: Patients scheduled for carotid endarterectomy underwent four-point Dixon and T1-weighted magnetic resonance imaging (MRI) at 3 Tesla. Fat and R2* maps were generated from the Dixon sequence at the acquired spatial resolution of 0.60 × 0.60 × 0.70 mm voxel size. MRI and three-dimensional (3D) histology volumes of plaques were registered. The registration matrix was applied to segmentations denoting LRNC and IPH in 3D histology to split plaque volumes in regions with and without LRNC and IPH. RESULTS: Five patients were included. Regarding volumes of LRNC identified by 3D histology, the average fat fraction by MRI was significantly higher inside LRNC than outside: 12.64 ± 0.2737% versus 9.294 ± 0.1762% (mean ± standard error of the mean [SEM]; P < 0.001). The same was true for IPH identified by 3D histology, R2* inside versus outside IPH was: 71.81 ± 1.276 s-1 versus 56.94 ± 0.9095 s-1 (mean ± SEM; P < 0.001). There was a strong correlation between the cumulative fat and the volume of LRNC from 3D histology (R2 = 0.92) as well as between cumulative R2* and IPH (R2 = 0.94). CONCLUSION: Quantitative mapping of fat and R2* from Dixon MRI reliably quantifies the extent of LRNC and IPH. Magn Reson Med 78:285-296, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Tecido Adiposo/metabolismo , Tecido Adiposo/patologia , Doenças das Artérias Carótidas/metabolismo , Doenças das Artérias Carótidas/patologia , Hemorragia/metabolismo , Hemorragia/patologia , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/metabolismo , Doenças das Artérias Carótidas/diagnóstico por imagem , Hemorragia/diagnóstico por imagem , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Metabolismo dos Lipídeos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Modelos Estatísticos , Imagem Molecular/métodos , Necrose/diagnóstico por imagem , Necrose/metabolismo , Necrose/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador
11.
BMC Med Imaging ; 16: 26, 2016 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-27021353

RESUMO

BACKGROUND: Magnetic Resonance Imaging (MRI) 2D phase-contrast flow measurement has been regarded as the gold standard in blood flow measurements and can be performed with free breathing or breath held techniques. We hypothesized that the accuracy of flow measurements obtained with segmented phase-contrast during breath holding, and in particular higher number of k-space segments, would be non-inferior compared to navigator phase-contrast. Volumes obtained from anatomic segmentation of cine MRI and Doppler echocardiography were used for additional reference. METHODS: Forty patients, five women and 35 men, mean age 65 years (range 53-80), were randomly selected and consented to the study. All underwent EKG-gated cardiac MRI including breath hold cine, navigator based free-breathing phase-contrast MRI and breath hold phase-contrast MRI using k-space segmentation factors 3 and 5, as well as transthoracic echocardiography within 2 days. RESULTS: In navigator based free-breathing phase-contrast flow, mean stroke volume and cardiac output were 79.7 ± 17.1 ml and 5071 ± 1192 ml/min, respectively. The duration of the acquisition was 50 ± 6 s. With k-space segmentation factor 3, the corresponding values were 77.7 ml ± 17.5 ml and 4979 ± 1211 ml/min (p = 0.15 vs navigator). The duration of the breath hold was 17 ± 2 s. K-space segmentation factor 5 gave mean stroke volume 77.9 ± 16.4 ml, cardiac output 5142 ± 1197 ml/min (p = 0.33 vs navigator), and breath hold time 11 ± 1 s. Anatomical segmentation of cine gave mean stroke volume and cardiac output 91.2 ± 20.8 ml and 5963 ± 1452 ml/min, respectively. Echocardiography was reliable in 20 of the 40 patients. The mean diameter of the left ventricular outflow tract was 20.7 ± 1.5 mm, stroke volume 78.3 ml ± 15.2 ml and cardiac output 5164 ± 1249 ml/min. CONCLUSIONS: In forty consecutive patients with coronary heart disease, breath holding and segmented k-space sampling techniques for phase-contrast flow produced stroke volumes and cardiac outputs similar to those obtained with free-breathing navigator based phase-contrast MRI, using less time. The values obtained agreed fairly well with Doppler echocardiography while there was a larger difference when compared with anatomical volume determinations using SSFP (steady state free precession) cine MRI.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Doença das Coronárias/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
12.
J Cardiovasc Magn Reson ; 17: 50, 2015 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-26104510

RESUMO

BACKGROUND: We hypothesised that myocardial deformation determined with magnetic resonance imaging (MRI) will detect myocardial scar. METHODS: Displacement Encoding with Stimulated Echoes (DENSE) was used to calculate left ventricular strain in 125 patients (29 women and 96 men) with suspected coronary artery disease. The patients also underwent cine imaging and late gadolinium enhancement. 57 patients had a scar area >1% in at least one segment, 23 were considered free from coronary artery disease (control group) and 45 had pathological findings but no scar (mixed group). Peak strain was calculated in eight combinations: radial and circumferential strain in transmural, subendocardial and epicardial layers derived from short axis acquisition, and transmural longitudinal and radial strain derived from long axis acquisitions. In addition, the difference between strain in affected segments and reference segments, "differential strain", from the control group was analysed. RESULTS: In receiver-operator-characteristic analysis for the detection of 50% transmurality, circumferential strain performed best with area-under-curve (AUC) of 0.94. Using a cut-off value of -17%, sensitivity was 95% at a specificity of 80%. AUC did not further improve with differential strain. There were significant differences between the control group and global strain circumferential direction (-17% versus -12%) and in the longitudinal direction (-13% versus -10%). Interobserver and scan-rescan reproducibility was high with an intraclass correlation coefficient (ICC) >0.93. CONCLUSIONS: DENSE-derived circumferential strain may be used for the detection of myocardial segments with >50 % scar area. The repeatability of strain is satisfactory. DENSE-derived global strain agrees with other global measures of left ventricular ejection fraction.


Assuntos
Cicatriz/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Contração Miocárdica , Infarto do Miocárdio/diagnóstico , Miocárdio/patologia , Volume Sistólico , Função Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Fenômenos Biomecânicos , Cicatriz/patologia , Cicatriz/fisiopatologia , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/patologia , Infarto do Miocárdio/fisiopatologia , Valor Preditivo dos Testes , Curva ROC , Reprodutibilidade dos Testes , Estresse Mecânico , Suécia
13.
Eur Radiol ; 23(1): 174-81, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22836161

RESUMO

OBJECTIVES: To apply dynamic contrast-enhanced (DCE) MRI on patients presenting with elevated liver enzymes without clinical signs of hepatic decompensation in order to quantitatively compare the hepatocyte-specific uptake of Gd-EOB-DTPA with histopathological fibrosis stage. METHODS: A total of 38 patients were prospectively examined using 1.5-T MRI. Data were acquired from regions of interest in the liver and spleen by using time series of single-breath-hold symmetrically sampled two-point Dixon 3D images (non-enhanced, arterial and venous portal phase; 3, 10, 20 and 30 min) following a bolus injection of Gd-EOB-DTPA (0.025 mmol/kg). The signal intensity (SI) values were reconstructed using a phase-sensitive technique and normalised using multiscale adaptive normalising averaging (MANA). Liver-to-spleen contrast ratios (LSC_N) and the contrast uptake rate (K (Hep)) were calculated. Liver biopsy was performed and classified according to the Batts and Ludwig system. RESULTS: Area under the receiver-operating characteristic curve (AUROC) values of 0.71, 0.80 and 0.78, respectively, were found for K (Hep), LSC_N10 and LSC_N20 with regard to severe versus mild fibrosis. Significant group differences were found for K (Hep) (borderline), LSC_N10 and LSC_N20. CONCLUSIONS: Liver fibrosis stage strongly influences the hepatocyte-specific uptake of Gd-EOB-DTPA. Potentially the normalisation technique and K (Hep) will reduce patient and system bias, yielding a robust approach to non-invasive liver function determination.


Assuntos
Meios de Contraste/farmacocinética , Gadolínio DTPA/farmacocinética , Cirrose Hepática/patologia , Adulto , Idoso , Área Sob a Curva , Biópsia , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Software , Ultrassonografia de Intervenção
15.
Front Cardiovasc Med ; 9: 949440, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35966533

RESUMO

Background: Myocardial infarction (MI) is a major cause of heart failure. Left ventricular adverse remodeling is common post-MI. Several studies have demonstrated a correlation between reduced myocardial strain and the development of adverse remodeling. Cardiac magnetic resonance (CMR) with fast-strain encoding (fast-SENC) or feature tracking (FT) enables rapid assessment of myocardial deformation. The aim of this study was to establish a head-to-head comparison of fast-SENC and FT in post-ST-elevated myocardial infarction (STEMI) patients, with clinical 2D speckle tracking echocardiography (2DEcho) as a reference. Methods: Thirty patients treated with primary percutaneous coronary intervention for STEMI were investigated. All participants underwent CMR examination with late gadolinium enhancement, cine-loop steady-state free precession, and fast-SENC imaging using a 1.5T scanner as well as a 2DEcho. Global longitudinal strain (GLS), segmental longitudinal strain (SLS), global circumferential strain (GCS), and segmental circumferential strain (SCS) were assessed along with the MI scar extent. Results: The GCS measurements from fast-SENC and FT were nearly identical: the mean difference was 0.01 (2.5)% (95% CI - 0.92 to 0.95). For GLS, fast-SENC values were higher than FT, with a mean difference of 1.8 (1.4)% (95% CI 1.31-2.35). Tests of significance for GLS did not show any differences between the MR methods and 2DEcho. Average strain in the infarct-related artery (IRA) segments compared to the remote myocardium was significantly lower for the left anterior descending artery and right coronary artery culprits but not for the left circumflex artery culprits. Fast-SENC displayed a higher area under the curve for detecting infarcted segments than FT for both SCS and SLS. Conclusion: GLS and GCS did not significantly differ between fast-SENC and FT. Both showed acceptable agreement with 2DEcho for longitudinal strain. Segments perfused by the IRA showed significantly reduced strain values compared to the remote myocardium. Fast-SENC presented a higher sensitivity and specificity for detecting infarcted segments than FT.

16.
Nephrol Dial Transplant ; 25(11): 3607-14, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20488819

RESUMO

BACKGROUND: The diagnostic value of non-invasive methods for diagnosing renal artery stenosis in patients with renal insufficiency is incompletely known. METHODS: Forty-seven consecutive patients with moderately impaired renal function and a clinical suspicion of renal artery stenosis were investigated with computed tomography angiography (CTA), gadolinium-enhanced magnetic resonance angiography (MRA), contrast-enhanced Doppler ultrasound and captopril renography. The primary reference standard was stenosis reducing the vessel diameter by at least 50% on CTA, and an alternative reference standard ('morphological and functional stenosis') was defined as at least 50% diameter reduction on CTA or MRA, combined with a positive finding from ultrasound or captopril renography. RESULTS: The frequency of positive findings, calculated on the basis of individual patients, was 70% for CTA, 60% for MRA, 53% for ultrasound and 30% for captopril renography. Counting kidneys rather than patients, corresponding frequencies were 53%, 41%, 29% and 15%, respectively. In relation to the CTA standard, the sensitivity (and specificity) at the patient level was 0.81 (0.79) for MRA, 0.70 (0.89) for ultrasound and 0.42 (1.00) for captopril renography, and at the kidney level 0.76 (0.82), 0.53 (0.81) and 0.30 (0.86), respectively. Relative to the alternative reference standard, corresponding values at the patient level were 1.00 (0.62) for CTA, 0.90 (0.69) for MRA, 0.91 (1.00) for ultrasound and 0.67 (1.00) for captopril renography, and at the kidney level 0.96 (0.76), 0.85 (0.79), 0.71 (0.97) and 0.50 (0.97), respectively. CONCLUSIONS: CTA and MRA are superior to ultrasound and captopril renography at diagnosing morphological stenosis, but ultrasound may be useful as a screening method and captopril renography for verifying renin-dependent hypertension.


Assuntos
Obstrução da Artéria Renal/diagnóstico , Insuficiência Renal/complicações , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Padrões de Referência , Artéria Renal/diagnóstico por imagem , Obstrução da Artéria Renal/patologia , Tomografia Computadorizada por Raios X
17.
BMC Med Imaging ; 10: 19, 2010 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-20716333

RESUMO

BACKGROUND: In Contrast Enhanced Magnetic Resonance Imaging fibrotic myocardium can be distinguished from healthy tissue using the difference in the longitudinal T1 relaxation after administration of Gadolinium, the so-called Late Gd Enhancement. The purpose of this work was to measure the myocardial absolute T1 post-Gd from a single breath-hold 3D Phase Sensitivity Inversion Recovery sequence (PSIR). Equations were derived to take the acquisition and saturation effects on the magnetization into account. METHODS: The accuracy of the method was investigated on phantoms and using simulations. The method was applied to a group of patients with suspected myocardial infarction where the absolute difference in relaxation of healthy and fibrotic myocardium was measured at about 15 minutes post-contrast. The evolution of the absolute R1 relaxation rate (1/T1) over time after contrast injection was followed for one patient and compared to T1 mapping using Look-Locker. Based on the T1 maps synthetic LGE images were reconstructed and compared to the conventional LGE images. RESULTS: The fitting algorithm is robust against variation in acquisition flip angle, the inversion delay time and cardiac arrhythmia. The observed relaxation rate of the myocardium is 1.2 s-1, increasing to 6 - 7 s-1 after contrast injection and decreasing to 2 - 2.5 s-1 for healthy myocardium and to 3.5 - 4 s-1 for fibrotic myocardium. Synthesized images based on the T1 maps correspond very well to actual LGE images. CONCLUSIONS: The method provides a robust quantification of post-Gd T1 relaxation for a complete cardiac volume within a single breath-hold.


Assuntos
Algoritmos , Gadolínio DTPA , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Infarto do Miocárdio/patologia , Meios de Contraste , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
18.
Oncoimmunology ; 5(10): e1229723, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27853653

RESUMO

Inflammation is one of the hallmarks of carcinogenesis. High mammographic density has been associated with increased risk of breast cancer but the mechanisms behind are poorly understood. We evaluated whether breasts with different mammographic densities exhibited differences in the inflammatory microenvironment. Postmenopausal women attending the mammography-screening program were assessed having extreme dense, n = 20, or entirely fatty breasts (nondense), n = 19, on their regular mammograms. Thereafter, the women were invited for magnetic resonance imaging (MRI), microdialysis for the collection of extracellular molecules in situ and a core tissue biopsy for research purposes. On the MRI, lean tissue fraction (LTF) was calculated for a continuous measurement of breast density. LTF confirmed the selection from the mammograms and gave a continuous measurement of breast density. Microdialysis revealed significantly increased extracellular in vivo levels of IL-6, IL-8, vascular endothelial growth factor, and CCL5 in dense breast tissue as compared with nondense breasts. Moreover, the ratio IL-1Ra/IL-1ß was decreased in dense breasts. No differences were found in levels of IL-1ß, IL-1Ra, CCL2, leptin, adiponectin, or leptin:adiponectin ratio between the two breast tissue types. Significant positive correlations between LTF and the pro-inflammatory cytokines as well as between the cytokines were detected. Stainings of the core biopsies exhibited increased levels of immune cells in dense breast tissue. Our data show that dense breast tissue in postmenopausal women is associated with a pro-inflammatory microenvironment and, if confirmed in a larger cohort, suggests novel targets for prevention therapies for women with dense breast tissue.

19.
Eur J Radiol Open ; 2: 66-70, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26937438

RESUMO

PURPOSE: Continuous monitoring of liver fibrosis progression in patients is not feasible with the current diagnostic golden standard (needle biopsy). Recently, magnetic resonance elastography (MRE) has emerged as a promising method for such continuous monitoring. Since there are different MRE methods that could be used in a clinical setting there is a need to investigate whether measurements produced by these MRE methods are comparable. Hence, the purpose of this pilot study was to evaluate whether the measurements of the viscoelastic properties produced by 2D (stiffness) and 3D (elasticity and 'G abs,Elastic') MRE are comparable. MATERIALS AND METHODS: Seven patients with diffuse or suspect diffuse liver disease were examined in the same day with the two MRE methods. 2D MRE was performed using an acoustic passive transducer, with a 1.5 T GE 450 W MR system. 3D MRE was performed using an electromagnetic active transducer, with a 1.5 T Philips Achieva MR system. Finally, mean viscoelastic values were extracted from the same anatomical region for both methods by an experienced radiologist. RESULTS: Stiffness correlated well with the elasticity, R (2) = 0.96 (P < 0.001; slope = 1.08, intercept = 0.61 kPa), as well as with 'G abs,Elastic' R (2) = 0.96 (P < 0.001; slope = 0.95, intercept = 0.28 kPa). CONCLUSION: This pilot study shows that different MRE methods can produce comparable measurements of the viscoelastic properties of the liver. The existence of such comparable measurements is important, both from a clinical as well as a research perspective, since it allows for equipment-independent monitoring of disease progression.

20.
PLoS One ; 7(12): e52227, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23284944

RESUMO

OBJECTIVE: Shear forces play a key role in the maintenance of vessel wall integrity. Current understanding regarding shear-dependent gene expression is mainly based on in vitro or in vivo observations with experimentally deranged shear, hence reflecting acute molecular events in relation to flow. Our objective was to combine computational fluid dynamic (CFD) simulations with global microarray analysis to study flow-dependent vessel wall biology in the aortic wall under physiological conditions. METHODS AND RESULTS: Male Wistar rats were used. Animal-specific wall shear stress (WSS) magnitude and vector direction were estimated using CFD based on aortic geometry and flow information acquired by magnetic resonance imaging. Two distinct flow pattern regions were identified in the normal rat aortic arch; the distal part of the lesser curvature being exposed to low WSS and a non-uniform vector direction, and a region along the greater curvature being subjected to markedly higher levels of WSS and a uniform vector direction. Microarray analysis identified numerous novel mechanosensitive genes, including Trpc4 and Fgf12, and confirmed well-known ones, e.g. Klf2 and Nrf2. Gene ontology analysis revealed an over-representation of genes involved in transcriptional regulation. The most differentially expressed gene, Hand2, is a transcription factor previously shown to be involved in extracellular matrix remodeling. HAND2 protein was endothelial specific and showed higher expression in the regions exposed to low WSS with disturbed flow. CONCLUSIONS: Microarray analysis validated the CFD-defined WSS regions in the rat aortic arch, and identified numerous novel shear-sensitive genes. Defining the functional importance of these genes in relation to atherosusceptibility may provide important insight into the understanding of vascular pathology.


Assuntos
Aorta/metabolismo , Aorta/fisiologia , Fatores de Transcrição Hélice-Alça-Hélice Básicos/metabolismo , Resistência ao Cisalhamento/fisiologia , Estresse Mecânico , Animais , Aorta Torácica/metabolismo , Aorta Torácica/fisiologia , Fatores de Transcrição Hélice-Alça-Hélice Básicos/genética , Masculino , Análise de Sequência com Séries de Oligonucleotídeos , Ratos , Ratos Wistar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA