Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 165
Filtrar
1.
J Mater Sci Mater Med ; 32(7): 81, 2021 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-34191141

RESUMO

Aside from being known for its excellent mechanical properties and aesthetic effect, zirconia has recently attracted attention as a new dental implant material. Many studies have focused on hydroxyapatite (HA) coating for obtaining improved biocompatibility, however the coating stability was reduced by a byproduct produced during the high-temperature sintering process. In this study, to overcome this problem, we simply coated the zirconia surface with a sol-gel-derived hydroxyapatite (HA) layer and then sintered it at a varied temperature (<1000 °C). The surface showed a nanoporous structure, and there was no crystalline phase other than HA and zirconia when the sintering temperature was 800 °C. The adhesion strength of the HA layer (>40 MPa) was also appropriate as a dental implant application. In addition, in vitro cell experiments using a preosteoblast cell line revealed that the HA-coated zirconia surface acts as a preferable surface for cell attachment and proliferation than bare zirconia surface. In vivo animal experiments also demonstrated that the osteoconductivity of zirconia were dramatically enhanced by HA coating, which was comparable to that of Ti implant. These results suggest that the sol-gel-based HA-coated zirconia has a great potential for use as a dental implant material.


Assuntos
Materiais Revestidos Biocompatíveis/química , Durapatita/química , Osseointegração , Transição de Fase , Zircônio/química , Animais , Adesão Celular , Linhagem Celular , Proliferação de Células , Implantes Dentários , Fêmur/patologia , Técnicas In Vitro , Teste de Materiais , Camundongos , Microscopia Eletrônica de Varredura , Pressão , Coelhos , Estresse Mecânico , Propriedades de Superfície , Temperatura , Titânio/química
2.
Adv Exp Med Biol ; 1077: 527-537, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30357707

RESUMO

Wound healing is a complex mechanism involving a variety of factors and is a representative process of tissue growth and regeneration in our body. Surface-based interactions between the dressing material and the wound may significantly influence the healing phase. Advances in understanding the mechanism of wound healing have led to the development of numerous dressing materials that can accelerate the healing process. However, these materials have a passive role in wound healing. It is therefore necessary to develop novel wound dressing materials, especially effective for clinically problematic wounds. Chitosan-based dressing materials are considered suitable for clinically problematic wounds as they exhibit several characteristic features, such as facilitating hemostasis, enhanced wound healing during the inflammatory and proliferative phases, antimicrobial effect, etc. Here, we review the current status of clinically available dressing materials and studies on the biological characteristics of chitosan, and discuss the potential applications of chitosan in multi-functional dressing materials for accelarated wound healing.


Assuntos
Bandagens , Quitosana , Cicatrização , Materiais Biocompatíveis , Hemostasia , Humanos
3.
J Craniofac Surg ; 28(2): 518-523, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28060094

RESUMO

INTRODUCTION: Nonabsorbable metallic membrane for guided bone regeneration is remained permanently even though after complete healing. There would be metallic exposure followed by the risk of infection; the membrane should be removed for the additional procedure such as implant installation. Since absorbable nonmetallic mesh is absorbed within 3 to 6 months, it is unnecessary to be removed. However, the absorbable membrane shows lower retention, lower mechanical strength, and difficulty of manipulation than the nonabsorbable ones.The purpose of this study is to evaluate the ability of absorbable metallic mesh (hydroxyapatite-coated magnesium mesh) with acceptable mechanical properties and satisfying biocompatibility. METHODS: The bioresorption and fate of magnesium were evaluated in Sprague Dawley rat (SD rat) with critical defect of calvarium. The critical defect with a diameter of 8 mm was made on calvarium using trephine bur in 18 SD rats. The defected models were divided into 2 groups: the control group (9 SD rat) without mesh and the experimental group (9 SD rat) with the insertion of prototype HA-coated magnesium mesh. The 3 SD rats were sacrificed at 6, 12, and 18 weeks. The histopathological and radiographic examinations were performed afterward. RESULTS: In the control group, there was no specific symptom. The experimental group also showed no specific symptom including swelling and dehiscence related to hydrogen gas formation. From 6 to 18 weeks, the experimental group showed the progressive absorption and fracture of magnesium mesh. However, there was no specific effectiveness of guided bone regeneration in both groups. There was no significant difference in bone volume, bone surface, and bone volume fraction between the negative control group and the group with magnesium mesh (P >0.05). CONCLUSION: Hydroxyapatite-coated magnesium mesh showed reasonable process of bioresorption and bony reaction; however, the effectiveness of guided bone regeneration and management of the bioresorption rate should be reconsidered.


Assuntos
Implantes Absorvíveis , Regeneração Óssea/fisiologia , Reabsorção Óssea/fisiopatologia , Durapatita , Magnésio , Animais , Masculino , Membranas Artificiais , Ratos Sprague-Dawley , Crânio/fisiologia , Telas Cirúrgicas , Cicatrização/fisiologia
4.
Biomacromolecules ; 17(3): 841-51, 2016 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-26878437

RESUMO

Hyaluronic acid (HAc) hydrogel exhibits excellent biocompatibility, but it has limited biomedical application due to its poor biomechanical properties as well as too-fast enzymatic degradation. In this study, we have developed an in situ precipitation process for the fabrication of a HAc-calcium phosphate nanocomposite hydrogel, after the formation of the glycidyl methacrylate-conjugated HAc (GMHA) hydrogels via photo-cross-linking, to improve the mechanical and biological properties under physiological conditions. In particular, our process facilitates the rapid incorporation of calcium phosphate (CaP) nanoparticles of uniform size and with minimal agglomeration into a polymer matrix, homogeneously. Compared with pure HAc, the nanocomposite hydrogels exhibit improved mechanical behavior. Specifically, the shear modulus is improved by a factor of 4. The biostability of the nanocomposite hydrogel was also significantly improved compared with that of pure HAc hydrogels under both in vitro and in vivo conditions.


Assuntos
Materiais Biocompatíveis/síntese química , Hidrogéis/síntese química , Nanocompostos/química , Animais , Materiais Biocompatíveis/efeitos adversos , Materiais Biocompatíveis/química , Fosfatos de Cálcio/química , Linhagem Celular , Ácido Hialurônico/química , Hidrogéis/efeitos adversos , Hidrogéis/química , Camundongos , Nanocompostos/efeitos adversos
5.
J Mater Sci Mater Med ; 27(2): 34, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26704551

RESUMO

The introduction of a protective coating layer to highly corrosive magnesium (Mg) has been proposed as one of the common approaches for improved corrosion resistance of Mg-based implants as load-bearing biomedical applications. However, only few studies have focused on the mechanical stability of the coated Mg under practical conditions where significant deformation of the load-bearing implants is induced during the surgical operation or under physiological environments. Therefore, in this study, we developed a dual coating system composed of an interlayer hydroxyapatite (HA) and a top layer poly-L-lactic acid (PLLA) to improve the coating stability under deformation of Mg alloy (WE43) substrate. The HA interlayer was directly formed on the Mg alloy surface, followed by dip-coating of PLLA. As the interlayer, HA improved the adhesion of PLLA by modulating nano- and microscale roughness, in addition to its inherently good bonding strength to Mg. The flexible and deformable top coating PLLA layer mitigated crack propagation in the HA layer under deformation. Thus, the dual coating layer provided good protection to the underlying WE43 from corrosion regardless of deformation. The enhanced corrosion behavior of dual-coated WE43 exhibited better mechanical and biological performance compared to the non-coated or single-coated WE43. Therefore, this dual coating layer on Mg is expected to accelerate Mg-based applications in biomedical devices.


Assuntos
Materiais Revestidos Biocompatíveis/química , Durapatita/química , Elasticidade , Ácido Láctico/química , Magnésio/química , Polímeros/química , Próteses e Implantes , Ligas/química , Animais , Fenômenos Biomecânicos , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Materiais Revestidos Biocompatíveis/farmacologia , Corrosão , Teste de Materiais , Camundongos , Osteoblastos/citologia , Osteoblastos/efeitos dos fármacos , Osteoblastos/fisiologia , Poliésteres , Propriedades de Superfície , Suporte de Carga
6.
J Oral Maxillofac Surg ; 72(2): 402.e1-13, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24280169

RESUMO

PURPOSE: The aim of this study was to evaluate the stress distribution of a magnesium (Mg)-based resorbable screw system in a bilateral sagittal split ramus osteotomy (BSSO) and to compare its biomechanical stability with those of titanium (Ti)-based and polymer (IN)-based systems. MATERIALS AND METHODS: A 3-dimensional BSSO model (10-mm advancement and setback) was constructed with Mimics. Bicortical screw fixation using Ti, IN, and Mg screws was performed with 4 different geometries of fixation. With an occlusal load of 132 N on the lower first molar, the von Mises stress (VMS) distribution was calculated using ANSYS. RESULTS: The VMS distribution of Mg was more similar to that of Ti than to that of IN. In all cases, the highest VMS was concentrated on the screw at the most posterior and superior area. Stress was distributed mainly around the screw holes (cancellous bone) and the retromolar area (cortical bone). In the advancement surgery, fixation with 5 Mg screws (5A-Mg, 99.810 MPa at cortical bone) showed biomechanical stability, whereas fixation with the same number of IN screws did not (5A-IN, 109.021 MPa at cortical bone). In the setback surgery, although the maximum VMSs at cortical bone for Mg, IN, and Ti were lower than 108 MPa (yield strength of cortical bone), Mg screws showed more favorable results than IN screws because the maximum VMSs of Mg at cancellous bone were lower than those of IN. CONCLUSION: The Mg-based resorbable screw system is a promising alternative to the IN-based system.


Assuntos
Parafusos Ósseos , Análise do Estresse Dentário , Imageamento Tridimensional/métodos , Magnésio , Osteotomia Sagital do Ramo Mandibular/instrumentação , Implantes Absorvíveis , Simulação por Computador , Análise do Estresse Dentário/métodos , Módulo de Elasticidade , Análise de Elementos Finitos , Polímeros , Resistência ao Cisalhamento , Titânio
7.
ACS Appl Mater Interfaces ; 16(24): 30967-30979, 2024 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-38857475

RESUMO

The ongoing global health has highlighted the critical issue of secondary infections, particularly antibiotic-resistant bacterial infections, which have been significant contributors to mortality rates. Orthopedic implants, while essential for trauma and orthopedic surgeries, are particularly susceptible to these infections, leading to severe complications and economic burdens. The traditional use of antibiotics in treating these infections poses further challenges including the risk of developing antibiotic-resistant bacteria. This study introduces a novel approach to combat this issue by developing nanostructured surfaces for orthopedic implants using target ion-induced plasma sputtering. Inspired by the natural design of dragonfly wings, these surfaces aim to prevent bacterial adhesion while promoting preosteoblast activity, offering a dual-function solution to the problems of bacterial infection and implant integration without relying on antibiotics. The in vitro results demonstrate the effectiveness of these bioinspired surfaces in eradicating bacteria and supporting cell proliferation and differentiation, presenting a promising alternative for the development of biomedical implants.


Assuntos
Antibacterianos , Osseointegração , Antibacterianos/farmacologia , Antibacterianos/química , Animais , Osseointegração/efeitos dos fármacos , Nanoestruturas/química , Camundongos , Propriedades de Superfície , Staphylococcus aureus/efeitos dos fármacos , Próteses e Implantes , Aderência Bacteriana/efeitos dos fármacos , Osteoblastos/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Linhagem Celular
8.
Int J Biol Macromol ; 254(Pt 3): 127797, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37949272

RESUMO

Biodegradable orthopedic implants are essential for restoring the physiological structure and function of bone tissue while ensuring complete degradation after recovery. Polylactic acid (PLA), a biodegradable polymer, is considered a promising material due to its considerable mechanical properties and biocompatibility. However, further improvements are necessary to enhance the mechanical strength and bioactivity of PLA for reliable load-bearing orthopedic applications. In this study, a multifunctional PLA-based composite was fabricated by incorporating tricalcium phosphate (TCP) microspheres and magnesium (Mg) particles homogenously at a volume fraction of 40 %. This approach aims to enhance mechanical strength, accelerate pore generation, and improve biological and antibacterial performance. Mg content was incorporated into the composite at varying values of 1, 3, and 5 vol% (referred to as PLA/TCP-1 Mg, PLA/TCP-3 Mg, and PLA/TCP-5 Mg, respectively). The compressive strength and stiffness were significantly enhanced in all composites, reaching 87.7, 85.9, and 84.1 MPa, and 2.7, 3.0, and 3.1 GPa, respectively. The degradation test indicated faster elimination of the reinforcers as the Mg content increased, resulting in accelerated pore generation to induce enhanced osseointegration. Because PLA/TCP-3 Mg and PLA/TCP-5 Mg exhibited cracks in the PLA matrix due to rapid corrosion of Mg forming corrosion byproducts, to optimize the Mg particle content, PLA/TCP-1 Mg was selected for further evaluation. As determined by in vitro biological and antibacterial testing, PLA/TCP-1 Mg showed enhanced bioactivity with pre-osteoblast cells and exhibited antibacterial properties by suppressing bacterial colonization. Overall, the multifunctional PLA/TCP-Mg composite showed improved mechanobiological performance, making it a promising material for biodegradable orthopedic implants.


Assuntos
Magnésio , Osseointegração , Magnésio/farmacologia , Magnésio/química , Poliésteres/farmacologia , Poliésteres/química , Antibacterianos/farmacologia , Teste de Materiais , Fosfatos de Cálcio/farmacologia , Fosfatos de Cálcio/química , Materiais Biocompatíveis/farmacologia , Materiais Biocompatíveis/química
9.
J Mater Sci Mater Med ; 24(3): 773-82, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23344924

RESUMO

In this study, a silica xerogel-chitosan hybrid is utilized as a coating material to incorporate bone morphogenic protein-2 (BMP-2) on a porous hydroxyapatite (HA) scaffold for bone tissue engineering. BMP-2 is known as a therapeutic agent for improving bone regeneration and repair. Silica xerogel-chitosan hybrids have been used for the delivery of a growth factor as well as osteoconductive coatings. The biological properties of the hybrid coating incorporated with BMP-2 were evaluated in terms of the BMP-2 release behavior, osteoblastic cellular responses and in vivo performance. BMP-2 was continuously released from the hybrid coating layer on the porous HA scaffold for up to 6 weeks. The hybrid coating containing BMP-2 showed significantly enhanced osteoblastic cell responses in comparison with the hybrid coating and HA substrate. Consequently, new bone formation was significantly increased within the hybrid coating containing BMP-2. These results reveal that the hybrid coating containing BMP-2 has the potential to be used as a bone implant, whose osteogenic properties are promoted by the release of BMP-2 in a controlled manner for a prolonged period of time.


Assuntos
Proteína Morfogenética Óssea 2/administração & dosagem , Durapatita , Engenharia Tecidual , Alicerces Teciduais , Animais , Sequência de Bases , Primers do DNA , Microscopia Eletrônica de Varredura , Reação em Cadeia da Polimerase , Coelhos , Tomografia Computadorizada por Raios X
10.
Materials (Basel) ; 16(1)2023 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-36614741

RESUMO

This study reports the utility of solid camphor as a novel diluent in photocurable hexanediol diacrylate (HDDA) monomer to manufacture 4 mol% yttria partially stabilized zirconia (4Y-PSZ) components for dental applications by digital light processing (DLP). The use of a 65 wt% HDDA-35 wt% camphor solution allowed 4Y-PSZ suspensions to have reasonably low viscosities (1399 ± 55.8 mPa·s at a shear rate of 75 s-1), measured by a cone/plate viscometer, at a high solid loading of 48 vol%, where 4Y-PSZ particles prepared by calcination of as-received 4Y-PSZ granules, followed by a ball-milling process, were used with assistance of a dispersant. These 4Y-PSZ suspensions could be successfully applied to our custom-made DLP machine for manufacturing 4Y-PSZ components. To this end, several processing parameters, including layer thickness of 4Y-PSZ suspension, UV illumination time for layer-by-layer photocuring process, and initial dimensions of 4Y-PSZ objects, were tightly controlled. As sintering temperature increased from 1300 °C to 1500 °C, relative density and grain size of 4Y-PSZ objects increased, and cubic phase content also increased. Thus, after sintering at the highest temperature of 1500 °C for 3 h, high mechanical properties (biaxial flexural strength = 911 ± 40.7 MPa, hardness = 1371 ± 14.4 Hv) and reasonably high optical transmittance (translucency parameter = 7.77 ± 0.32, contrast ratio = 0.809 ± 0.007), evaluated by a spectrophotometer, were obtained due to a high relative density (97.2 ± 1.38%), which would be useful for dental applications.

11.
Materials (Basel) ; 16(4)2023 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-36837076

RESUMO

We herein report manufacturing of dental crowns made of 5-mol% yttria partially stabilized zirconia (5Y-PSZ) with desired mechanical properties, optical translucency and dimensional accuracy using digital light processing (DLP). To this end, all processing parameters were carefully controlled and optimized. First, 5Y-PSZ particles with a bimodal distribution were prepared via calcination of as-received granules and subsequent ball-milling and then used to formulate 5Y-PSZ suspensions with a high solid loading of 50 vol% required for high densification after sintering. Dispersant content was also optimized. To provide high dimensional accuracy, initial dimensions of dental crowns for 3D printing were precisely determined by considering increase and decrease in dimensions during photopolymerization and sintering, respectively. Photopolymerization time was also optimized for a given layer thickness of 50 µm to ensure good bonding between layers. A multi-step debinding schedule with a slow heating rate was employed to avoid formation of any defects. After sintering at 1500 °C for 2 h, 5Y-PSZ could be almost fully densified without noticeable defects within layers and at interfaces between layers. They had high relative densities (99.03 ± 0.39%) with a high cubic phase content (59.1%). These characteristics allowed for achievement of reasonably high mechanical properties (flexural strength = 625.4 ± 75.5 MPa and Weibull modulus = 7.9) and % transmittance (31.4 ± 0.7%). In addition, 5Y-PSZ dental crowns showed excellent dimensional accuracy (root mean square (RMS) for marginal discrepancy = 44.4 ± 10.8 µm and RMS for internal gap = 22.8 ± 1.6 µm) evaluated by the 3D scanning technique.

12.
Biomater Adv ; 152: 213523, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37336010

RESUMO

Biodegradability, bone-healing rate, and prevention of bacterial infection are critical factors for orthopedic implants. Polylactic acid (PLA) is a good candidate biodegradable material; however, it has insufficient mechanical strength and bioactivity for orthopedic implants. Magnesium (Mg), has good bioactivity, biodegradability, and sufficient mechanical properties, similar to that of bone. Moreover, Mg has an inherent antibacterial property via a photothermal effect, which generates localized heat, thus preventing bacterial infection. Therefore, Mg is a good candidate material for PLA composites, to improve their mechanical and biological performance and add an antibacterial property. Herein, we fabricated an antibacterial PLA/Mg composite for enhanced mechanical and biological performance with an antibacterial property for application as biodegradable orthopedic implants. The composite was fabricated with 15 and 30 vol% of Mg homogeneously dispersed in PLA without the generation of a defect using a high-shear mixer. The composites exhibited an enhanced compressive strength of 107.3 and 93.2 MPa, and stiffness of 2.3 and 2.5 GPa, respectively, compared with those of pure PLA which were 68.8 MPa and 1.6 GPa, respectively. Moreover, the PLA/Mg composite at 15 vol% Mg exhibited significant improvement of biological performance in terms of enhanced initial cell attachment and cell proliferation, whereas the composite at 30 vol% Mg showed deteriorated cell proliferation and differentiation because of the rapid degradation of the Mg particles. In turn, the PLA/Mg composites exerted an antibacterial effect based on the inherent antibacterial property of Mg as well as the photothermal effect induced by near-infrared (NIR) treatment, which can minimize infection after implantation surgery. Therefore, antibacterial PLA/Mg composites with enhanced mechanical and biological performance may be a candidate material with great potential for biodegradable orthopedic implants.


Assuntos
Magnésio , Poliésteres , Magnésio/farmacologia , Implantes Absorvíveis , Antibacterianos/farmacologia
13.
Adv Sci (Weinh) ; 10(17): e2300816, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37076933

RESUMO

Chronic wounds in diabetic patients are challenging because their prolonged inflammation makes healing difficult, thus burdening patients, society, and health care systems. Customized dressing materials are needed to effectively treat such wounds that vary in shape and depth. The continuous development of 3D-printing technology along with artificial intelligence has increased the precision, versatility, and compatibility of various materials, thus providing the considerable potential to meet the abovementioned needs. Herein, functional 3D-printing inks comprising DNA from salmon sperm and DNA-induced biosilica inspired by marine sponges, are developed for the machine learning-based 3D-printing of wound dressings. The DNA and biomineralized silica are incorporated into hydrogel inks in a fast, facile manner. The 3D-printed wound dressing thus generates provided appropriate porosity, characterized by effective exudate and blood absorption at wound sites, and mechanical tunability indicated by good shape fidelity and printability during optimized 3D printing. Moreover, the DNA and biomineralized silica act as nanotherapeutics, enhancing the biological activity of the dressings in terms of reactive oxygen species scavenging, angiogenesis, and anti-inflammation activity, thereby accelerating acute and diabetic wound healing. These bioinspired 3D-printed hydrogels produce using a DNA-induced biomineralization strategy are an excellent functional platform for clinical applications in acute and chronic wound repair.


Assuntos
Diabetes Mellitus , Hidrogéis , Masculino , Humanos , Hidrogéis/farmacologia , Inteligência Artificial , Biomineralização , Sêmen , Cicatrização , Impressão Tridimensional
14.
Materials (Basel) ; 15(11)2022 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-35683172

RESUMO

This study demonstrates the utility of thermo-regulated phase separable alumina/camphene suspensions containing poly(methyl methacrylate) (PMMA) microspheres as porogens for the production of multi-scale porosity structures. The homogeneous suspension prepared at 60 °C could undergo phase separation during freezing at room temperature. This process resulted in the 3D networks of camphene crystals and alumina walls containing PMMA microspheres. As a consequence, relatively large dendritic pores with several tens of microns size could be created as the replica of frozen camphene crystals. In addition, after the removal of PMMA microspheres via heat-treatment, micron-sized small spherical pores could be generated in alumina walls. As the PMMA content with respect to the alumina content increased from 0 vol% to 40 vol%, while the camphene content in the suspensions was kept constant (70 vol%), the overall porosity increased from 45.7 ± 0.5 vol% to 71.4 ± 0.5 vol%. This increase in porosity is attributed to an increase in the fraction of spherical pores in the alumina walls. Thus, compressive strength decreased from 153 ± 18.3 MPa to 33 ± 7.2 MPa. In addition, multi-scale porosity alumina objects with a honeycomb structure comprising periodic hexagonal macrochannels surrounded by dual-scale porosity walls were constructed using a 3D plotting technique.

15.
Bioact Mater ; 9: 239-250, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34820568

RESUMO

In recent years, pure iron (Fe) has attracted significant attention as a promising biodegradable orthopedic implant material due to its excellent mechanical and biological properties. However, in physiological conditions, Fe has an extremely slow degradation rate with localized and irregular degradation, which is problematic for practical applications. In this study, we developed a novel combination of a nanostructured surface topography and galvanic reaction to achieve uniform and accelerated degradation of an Fe implant. The target-ion induced plasma sputtering (TIPS) technique was applied on the Fe implant to introduce biologically compatible and electrochemically noble tantalum (Ta) onto its surface and develop surface nano-galvanic couples. Electrochemical tests revealed that the uniformly distributed nano-galvanic corrosion cells of the TIPS-treated sample (nano Ta-Fe) led to relatively uniform and accelerated surface degradation compared to that of bare Fe. Furthermore, the mechanical properties of nano Ta-Fe remained almost constant during a long-term in vitro immersion test (~40 weeks). Biocompatibility was also assessed on surfaces of bare Fe and nano Ta-Fe using in vitro osteoblast responses through direct and indirect contact assays and an in vivo rabbit femur medullary cavity implantation model. The results revealed that nano Ta-Fe not only enhanced cell adhesion and spreading on its surface, but also exhibited no signs of cellular or tissue toxicity. These results demonstrate the immense potential of Ta-implanted surface nanostructures as an effective solution for the practical application of Fe-based orthopedic implants, ensuring long-term biosafety and clinical efficacy.

16.
J Mater Sci Mater Med ; 22(12): 2757-64, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22002514

RESUMO

A hybrid material composed of a silica xerogel and chitosan was coated on Ti for the delivery of growth-factors. Fibroblast growth factor (FGF) and green fluorescence protein were incorporated into the coatings for hard tissue engineering. Silica was chosen as a coating material because of its high surface area as well as its good bioactivity. Chitosan provides mechanical stability and contributes to the control of the release rate of the growth factors. When the chitosan composition was 30% or more, the hybrid coating was stable physically and mechanically. The release of the growth-factors, observed in phosphate buffer solution at 37°C, was strongly dependent on the coating material. The hybrid coating containing FGF showed significantly improved osteoblast cell responses compared to the pure xerogel coating with FGF or the hybrid coating without FGF. These results indicate that the hybrid coating is potentially very useful in enhancing the bioactivity of metallic implants by delivering growth-factors in a controlled manner.


Assuntos
Quitosana/química , Preparações de Ação Retardada , Sistemas de Liberação de Medicamentos , Peptídeos e Proteínas de Sinalização Intercelular/administração & dosagem , Dióxido de Silício/química , Titânio/química , Células 3T3 , Animais , Materiais Revestidos Biocompatíveis , Fatores de Crescimento de Fibroblastos/administração & dosagem , Géis , Proteínas de Fluorescência Verde/química , Humanos , Teste de Materiais , Camundongos , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Temperatura
17.
J Mater Sci Mater Med ; 22(10): 2231-7, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21837553

RESUMO

This study reports the deposition of TiN films on Co-Cr substrates to improve the substrates' mechanical properties and biological properties. In particular, the argon to nitrogen (Ar:N(2)) gas flow ratio was adjusted to control the microstructure of the TiN films. A Ti interlayer was also used to enhance the adhesion strength between the Co-Cr substrate and TiN films. A series of TiN films, which are denoted as TiN-(Ar/N(2))1:1, Ti/TiN-(Ar/N(2))1:1, and Ti/TiN-(Ar:N(2))1:3, were deposited by reactive DC sputtering. All the deposited TiN films showed a dense, columnar structure with a preferential orientation of the (200) plane. These TiN films increased the mechanical properties of Co-Cr, such as the critical load during scratch testing, hardness, elastic modulus and plastic resistance. In addition, the biological properties of the Co-Cr substrates, i.e. initial attachment, proliferation, and cellular differentiation of the MC3T3-E1 cells, were improved considerably by deposition of the TiN films. These results suggest that TiN films would effectively enhance both the mechanical properties and biocompatibility of biomedical Co-Cr alloys.


Assuntos
Ligas de Cromo/química , Titânio/química , Células 3T3 , Animais , Materiais Biocompatíveis/química , Adesão Celular , Diferenciação Celular , Proliferação de Células , Teste de Materiais , Camundongos , Microscopia Eletrônica de Varredura , Estresse Mecânico
18.
J Mater Sci Mater Med ; 22(11): 2437-47, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21909643

RESUMO

Hydroxyapatite (HA) was coated onto pure magnesium (Mg) with an MgF(2) interlayer in order to reduce the surface corrosion rate and enhance the biocompatibility. Both MgF(2) and HA were successfully coated in sequence with good adhesion properties using the fluoride conversion coating and aerosol deposition techniques, respectively. In a simulated body fluid (SBF), the double layer coating remarkably enhanced the corrosion resistance of the coated Mg specimen. The in vitro cellular responses of the MC3T3-E1 pre-osteoblasts were examined using a cell proliferation assay and an alkaline phosphatase (ALP) assay, and these results demonstrated that the double coating layer also enhanced cell proliferation and differentiation levels. In the in vivo study, the HA/MgF(2) coated Mg corroded less than the bare Mg and had a higher bone-to-implant contact (BIC) ratio in the cortical bone area of the rabbit femora 4 weeks after implantation. These in vitro and in vivo results suggested that the HA coated Mg with the MgF(2) interlayer could be used as a potential candidate for biodegradable implant materials.


Assuntos
Materiais Biocompatíveis/química , Durapatita/química , Fluoretos/química , Compostos de Magnésio/química , Células 3T3 , Implantes Absorvíveis , Animais , Substitutos Ósseos , Corrosão , Teste de Materiais , Camundongos , Coelhos , Propriedades de Superfície
19.
Mater Sci Eng C Mater Biol Appl ; 127: 112239, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34225879

RESUMO

Biodegradable magnesium (Mg)-based vascular stents can overcome the limitations of conventional permanent metallic stents, such as late in-stent restenosis and thrombosis, but still have difficulty retarding degradation while providing adequate mechanical support to the blood vessel. We incorporated silica nanoparticles surface-functionalized with hexadecyltrimethoxysilane (mSiNP) into a poly (l-lactic acid) (PLLA) coating as a physical barrier to disturb the penetration of the corrosive medium as well as a bioactive source that releases silicon ions capable of stimulating endothelial cells. The corrosion resistance and biocompatibility of this bifunctional PLLA/mSiNP nanocomposite coating were investigated using different weight ratios of mSiNP. The nanocomposite coating containing more than 10 wt% of the mSiNP (PLLA/10mSiNP and PLLA/20mSiNP) significantly delayed the corrosion of the Mg substrate and exhibited favorable endothelial cell responses, compared to the pure PLLA coating. Specifically, the calculated corrosion rates of PLLA/10mSiNP and PLLA/20mSiNP decreased by half, indicating the durability of the coating after immersion in simulated body fluid for 12 days. Based on the in vitro cellular response, the incorporation of the mSiNPs into the PLLA coating significantly improved the endothelial cell responses to the Mg substrate, showing better initial cell surface coverage, migration, and proliferation rate than those of pure PLLA. These results indicate that the PLLA/mSiNP nanocomposite coatings have significant potential to improve the corrosion resistance and vascular compatibility of biodegradable Mg-based vascular stents.


Assuntos
Magnésio , Nanocompostos , Materiais Revestidos Biocompatíveis/farmacologia , Corrosão , Células Endoteliais , Ácido Láctico , Teste de Materiais , Poliésteres , Dióxido de Silício , Stents
20.
Nanomaterials (Basel) ; 11(6)2021 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-34200329

RESUMO

Nano-scale surface roughening of metallic bio-implants plays an important role in the clinical success of hard tissue reconstruction and replacement. In this study, the nano-topographical features of titanium-niobium-zirconium (TNZ) alloy surfaces were controlled by using the target-ion induced plasma sputtering (TIPS) technique to improve the in vitro osteoblastic response. The TIPS technique is a novel strategy for etching the surface of metallic bio-implants using bombardment of target metal cations, which were accelerated by an extremely high negative bias voltage applied to the substrates. The nano-topography of the TNZ surfaces was successfully controlled by modulating experimental variables (such as the ion etching energy and the type of substrate or target materials) of TIPS. As a result, various nanopatterns (size: 10-210 nm) were fabricated on the surface of the TNZ alloys. Compared with the control group, experimental groups with nanopattern widths of ≥130 nm (130 and 210 nm groups) exhibited superior cell adhesion, proliferation, and differentiation. Our findings demonstrate that TIPS is a promising technology that can impart excellent biological functions to the surface of metallic bio-implants.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA