Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 71
Filtrar
1.
Phys Rev Lett ; 130(11): 111801, 2023 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-37001070

RESUMO

We present the first search for the pair production of dark particles X via K_{L}^{0}→XX with X decaying into two photons using the data collected by the KOTO experiment. No signal was observed in the mass range of 40-110 MeV/c^{2} and 210-240 MeV/c^{2}. This sets upper limits on the branching fractions as B(K_{L}^{0}→XX)<(1-4)×10^{-7} and B(K_{L}^{0}→XX)<(1-2)×10^{-6} at the 90% confidence level for the two mass regions, respectively.

2.
Phys Rev Lett ; 126(12): 121801, 2021 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-33834796

RESUMO

The rare decay K_{L}→π^{0}νν[over ¯] was studied with the dataset taken at the J-PARC KOTO experiment in 2016, 2017, and 2018. With a single event sensitivity of (7.20±0.05_{stat}±0.66_{syst})×10^{-10}, three candidate events were observed in the signal region. After unveiling them, contaminations from K^{±} and scattered K_{L} decays were studied, and the total number of background events was estimated to be 1.22±0.26. We conclude that the number of observed events is statistically consistent with the background expectation. For this dataset, we set an upper limit of 4.9×10^{-9} on the branching fraction of K_{L}→π^{0}νν[over ¯] at the 90% confidence level.

3.
Phys Rev Lett ; 122(2): 021802, 2019 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-30720307

RESUMO

A search for the rare decay K_{L}→π^{0}νν[over ¯] was performed. With the data collected in 2015, corresponding to 2.2×10^{19} protons on target, a single event sensitivity of (1.30±0.01_{stat}±0.14_{syst})×10^{-9} was achieved and no candidate events were observed. We set an upper limit of 3.0×10^{-9} for the branching fraction of K_{L}→π^{0}νν[over ¯] at the 90% confidence level (C.L.), which improved the previous limit by almost an order of magnitude. An upper limit for K_{L}→π^{0}X^{0} was also set as 2.4×10^{-9} at the 90% C.L., where X^{0} is an invisible boson with a mass of 135 MeV/c^{2}.

4.
BMC Public Health ; 18(1): 843, 2018 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-29980242

RESUMO

BACKGROUND: In Norway, data on the association between second-hand tobacco smoke (SHS) exposure at home and respiratory symptoms in adults are limited. METHODS: We assessed the association between self-reported exposure to SHS and the prevalence of respiratory symptoms among never-smokers aged 16 to 50 years from the general population who were included in a cross-sectional population-based study in Telemark County, Norway. Logistic regression analysis was used to estimate the odds ratios of symptoms among 8850 never-smokers who provided an affirmative response to questions regarding SHS; 504 (5.7%) of these reported that they lived in a home with daily or occasional indoor smoking. RESULTS: Productive cough and nocturnal dyspnoea were statistically associated with daily SHS exposure (ORs 1.5 [95% CI 1.04-2.0] and 1.8 [1.2-2.7], respectively). In analyses stratified by gender, nocturnal dyspnoea was associated with SHS among women (OR 1.8 [1.1-3.1]), but not among men (OR 0.93 [0.49-1.8]). Symptoms were not associated with occasional SHS exposure in the entire group, but infrequent exposure among men only was associated with increased prevalence of chronic cough; (OR 1.6; [1.04-2.6]) and was negatively associated with wheeze; (OR 0.44 [0.21-0.92)]. CONCLUSIONS: Daily SHS exposure in private homes was associated with productive cough and nocturnal dyspnoea. Our results suggest that preventive measures may be needed to reduce the respiratory effects of SHS at home. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02073708 Registered February 27. 2014.


Assuntos
Exposição Ambiental/efeitos adversos , não Fumantes/estatística & dados numéricos , Doenças Respiratórias/epidemiologia , Poluição por Fumaça de Tabaco/efeitos adversos , Adolescente , Adulto , Estudos Transversais , Exposição Ambiental/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Noruega/epidemiologia , Prevalência , Autorrelato , Poluição por Fumaça de Tabaco/estatística & dados numéricos , Adulto Jovem
5.
Acta Paediatr ; 99(1): 72-7, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19817726

RESUMO

AIM: To study the associations between fish intake and academic achievement as cognitive parameter among Swedish adolescents. METHODS: In 2000, a questionnaire including respiratory items, socioeconomic conditions and dietary information was mailed to all schoolchildren (n = 18 158), aged 15 and living in Västra Götaland region of Sweden. The questionnaire was returned by 10 837 subjects. One year later, the total school grades for each subject who had completed the questionnaire and who included their full personal identification number were obtained from the national registers. Multiple linear regression models were applied to evaluate the association between fish intake and academic grades among 9448 schoolchildren, while adjusting for potential confounders, e.g. parents' education. RESULTS: Grades were higher in subjects with fish consumption once a week compared with subjects with fish consumption of less than once a week (reference group) [increment in estimate 14.5, 95% confidence interval (CI) 11.8-17.1]. Grades were even higher in subjects with fish consumption of more than once a week compared with the reference group (increment in estimate 19.9, 95% CI 16.5-23.3). In the model stratified for parents' education, there were still higher grades among subjects with frequent fish intake in all educational strata (p < 0.01). CONCLUSION: Frequent fish intake among schoolchildren may provide benefits in terms of academic achievement.


Assuntos
Logro , Comportamento do Adolescente/psicologia , Dieta/estatística & dados numéricos , Peixes , Psicologia do Adolescente , Adolescente , Animais , Índice de Massa Corporal , Escolaridade , Exercício Físico , Ácidos Graxos Ômega-3/farmacologia , Feminino , Seguimentos , Humanos , Modelos Lineares , Masculino , Análise Multivariada , Estudos Prospectivos , Valores de Referência , Fatores Socioeconômicos , Inquéritos e Questionários , Suécia
6.
Epidemiol Psychiatr Sci ; 29: e176, 2020 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-33077022

RESUMO

AIMS: To investigate the association between parity and the risk of incident dementia in women. METHODS: We pooled baseline and follow-up data for community-dwelling women aged 60 or older from six population-based, prospective cohort studies from four European and two Asian countries. We investigated the association between parity and incident dementia using Cox proportional hazards regression models adjusted for age, educational level, hypertension, diabetes mellitus and cohort, with additional analysis by dementia subtype (Alzheimer dementia (AD) and non-Alzheimer dementia (NAD)). RESULTS: Of 9756 women dementia-free at baseline, 7010 completed one or more follow-up assessments. The mean follow-up duration was 5.4 ± 3.1 years and dementia developed in 550 participants. The number of parities was associated with the risk of incident dementia (hazard ratio (HR) = 1.07, 95% confidence interval (CI) = 1.02-1.13). Grand multiparity (five or more parities) increased the risk of dementia by 30% compared to 1-4 parities (HR = 1.30, 95% CI = 1.02-1.67). The risk of NAD increased by 12% for every parity (HR = 1.12, 95% CI = 1.02-1.23) and by 60% for grand multiparity (HR = 1.60, 95% CI = 1.00-2.55), but the risk of AD was not significantly associated with parity. CONCLUSIONS: Grand multiparity is a significant risk factor for dementia in women. This may have particularly important implications for women in low and middle-income countries where the fertility rate and prevalence of grand multiparity are high.


Assuntos
Doença de Alzheimer/epidemiologia , Demência/epidemiologia , Paridade/fisiologia , Idoso , Idoso de 80 Anos ou mais , China/epidemiologia , Estudos de Coortes , Europa (Continente)/epidemiologia , Feminino , Psiquiatria Geriátrica , Humanos , Incidência , Vida Independente , Pessoa de Meia-Idade , Gravidez , Modelos de Riscos Proporcionais , República da Coreia/epidemiologia , Fatores de Risco , Fatores Socioeconômicos
7.
Indoor Air ; 19(5): 392-400, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19500176

RESUMO

Abstract Sweden has had allergen-avoidance day care centers (AADCs) since 1979. The aim of this study was to measure fungal DNA by quantitative polymerase chain reaction (qPCR), a new method, in AADCs and ordinary day care centers (ODCs) and examine associations between allergen levels and building characteristics. Dust samples were collected by swabbing doorframes, vacuum-cleaning, and using Petri dishes. In total, 11 AADCs and 11 ODCs were studied (70 rooms). Total fungal DNA, measured by qPCR in the swab dust, was detected in 89%, Aspergillus or Penicillium (Asp/Pen) DNA in 34%, and Stachybotrys chartarum DNA in 6% of the rooms. Total fungal DNA was significantly higher in rooms with linoleum floor (P = 0.02), textile carpets (P = 0.03), reported dampness/molds (P = 0.02) and reported odor (P < 0.001) in the buildings, and significantly lower in wooden facade buildings (P = 0.003). Reported odor was related to the amount of sieved fine dust, reported dampness/molds and type of building construction. Total fungal DNA was related to cat, dog, horse and total allergen levels (P = 0.003) in the day care centers. In conclusion, total fungal DNA is related to reported dampness/molds, reported odor, and type of wall construction. The association between fungal and allergen contamination indicated a general 'hygiene factor' related to biological contaminants. Practical Implications The associations between fungal DNA, reported dampness/molds, and odor support the view that buildings with odor problems should be investigated for possible hidden fungal growth. There is a need to measure fungal biomass in different types of building constructions by monitoring fungal DNA. Analysis of fungal DNA with quantitative PCR can be a fast and practical way to study indoor fungal contamination. Swabbing dust from the doorframe of the main entrance to the room can be a convenient method of sampling dust for fungal DNA analysis. The high prevalence of reported dampness/molds and the common occurrence of fungal DNA indicate the need to improve the indoor environment of Swedish day care centers.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Alérgenos/análise , DNA Fúngico/análise , DNA Fúngico/genética , Poluição do Ar em Ambientes Fechados/prevenção & controle , Animais , Gatos , Creches , Pré-Escolar , Clima , Materiais de Construção/microbiologia , Cães , Poeira/análise , Feminino , Humanos , Masculino , Reação em Cadeia da Polimerase , Suécia
8.
Electromagn Biol Med ; 27(1): 73-82, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18327716

RESUMO

We developed whole-body exposure systems for in-vivo study at cellular (848.5 MHz) and Personal Communication System (PCS, 1,762.5 MHz) frequency, utilizing reverberation chamber. The field uniformities in the test area of the designed chambers were verified by simulation and measurement. In the whole-body exposure environment, Specific Absorption Rate (SAR) distributions inside of mice were calculated using Finite Difference Time Domain (FDTD) simulation. Key results are presented in this article.


Assuntos
Telefone Celular , Ondas de Rádio , Irradiação Corporal Total/instrumentação , Absorção/efeitos da radiação , Animais , Camundongos , Modelos Animais
9.
J Parasitol ; 93(5): 1225-7, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18163364

RESUMO

Plagiorchis vespertilionis (Digenea: Plagiorchiidae) is generally considered a bat parasite, but here it is reported for the first time in a human. The patient was a 34-yr-old male who lived in a coastal village of Haenam-gun (county), Jeollanam-do (province), Republic of Korea. Only 1 worm, 2.6 mm long and 0.7 mm wide, was recovered after praziquantel treatment and purging with magnesium salts. The fluke was characterized by a large body size, a sucker ratio of 1:1, a straight cirrus organ, a short distance between the ventral sucker and ovary, well-developed vitellaria, a uterus with descending and ascending loops, and fully developed eggs with an average size of 32.5 x 17.5 microm. The patient had habitually eaten the raw flesh of snakehead mullet and gobies that had been caught near his village. The present case represents the first record of a human P. vespertilionis infection.


Assuntos
Trematódeos/classificação , Infecções por Trematódeos/parasitologia , Adulto , Animais , Fezes/parasitologia , Peixes/parasitologia , Parasitologia de Alimentos , Humanos , Coreia (Geográfico)/epidemiologia , Masculino , Smegmamorpha/parasitologia , Trematódeos/anatomia & histologia , Trematódeos/isolamento & purificação , Infecções por Trematódeos/epidemiologia
10.
Radiat Prot Dosimetry ; 125(1-4): 229-32, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-16968712

RESUMO

LiF-based thermoluminescence (TL) materials have been widely used for radiation dosimetry due to their attractive features. LiF:Mg,Cu,P is one of the most sensitive tissue-equivalent TL materials, approximately 40 times more sensitive than LiF:Mg,Ti (TLD-100), but it has two main drawbacks: a thermal loss of the TL sensitivity when annealed at temperatures>240 degrees C, and a relatively high-residual signal. Recently, LiF:Mg,Cu,Na,Si TL material was developed to overcome these drawbacks at the Korea Atomic Energy Research Institute, but it provided only marginal improvements in reducing the residual signal. The newly developed LiF:Mg,Cu,Si TL material has a significantly lower residual signal and a better stability to thermal treatments. In this article, the preparation method and some dosimetric properties (sensitivity and residual signal) of the new LiF:Mg,Cu,Si TL material are presented. At the end of the preparation procedures, a dual-step annealing method is introduced and this has proved as a very efficient method to reduce the high-temperature peak and is the cause of residual signal. Therefore, the high-temperature peak in the glow curve was significantly reduced. The sensitivity is approximately 20 times higher than that of TLD-100 and the residual signal was estimated to be approximately 0.04%.


Assuntos
Exposição Ambiental/análise , Fluoretos/química , Fluoretos/efeitos da radiação , Compostos de Lítio/química , Compostos de Lítio/efeitos da radiação , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Internacionalidade , Teste de Materiais , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Temperatura
11.
Radiat Prot Dosimetry ; 126(1-4): 384-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17507384

RESUMO

High energy proton induced neutron fluence spectra were determined at the Korea Institute of Radiological and Medical Sciences (KIRAMS) using an extended Bonner Sphere (BS) set from the Korea Atomic Energy Research Institute (KAERI) in a series of measurements to quantify the neutron field. At the facility of the MC50 cyclotron of KIRAMS, two Be targets of different thicknesses, 1.0 and 10.5 mm, were bombarded by 35 and 45-MeV protons to produce six kinds of neutron fields, which were classified according to the measurement position and the use or no use of a beam collimator such as the gantry of the neutron therapy unit. In order to obtain a priori information to unfold the measured BS data the MCNPX code was used to calculate the neutron spectrum, and the influence of the surrounding materials for cooling the target assembly were also reviewed through this calculation. Some dosimetric quantities were determined by using the spectra determined in this measurement. Dose equivalent rates of these neutron fields ranged from 0.21 to 5.66 mSv h(-1)nA(-1) and the neutron yields for a thick Be target were 3.05 and 4.77% in the case of using a 35 and a 45-MeV proton, respectively.


Assuntos
Corpo Clínico , Modelos Biológicos , Nêutrons/uso terapêutico , Exposição Ocupacional/análise , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Structure ; 3(6): 531-4, 1995 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-8590013

RESUMO

Two recent crystal structures of the tetrameric pterin-4 alpha-carbinolamine dehydratase (PCD)/dimerization cofactor of HNF-1 (DCoH) protein provide fresh insights into how this multifunctional enzyme/transcriptional coactivator works.


Assuntos
Hidroliases/química , Hidroliases/metabolismo , Animais , Proteínas de Ligação a DNA/química , Fator 1 Nuclear de Hepatócito , Fator 1-beta Nuclear de Hepatócito , Proteínas Nucleares/química , Conformação Proteica , Fatores de Transcrição/química , Fatores de Transcrição/metabolismo
13.
Structure ; 6(1): 89-100, 1998 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-9493270

RESUMO

BACKGROUND: Hepatitis C virus (HCV) represents a major health concern as it is responsible for a significant number of hepatitis cases worldwide. Much research has focused on the replicative enzymes of HCV as possible targets for more effective therapeutic agents. HCV NS3 helicase may provide one such suitable target. Helicases are enzymes which can unwind double-stranded regions of DNA or RNA in an ATP-dependent reaction. The structures of several helicases have been published but the structural details as to how ATP binding and hydrolysis are coupled to RNA unwinding are unknown. RESULTS: The structure of the HCV NS3 RNA helicase domain complexed with a single-stranded DNA oligonucleotide has been solved to 2.2 A resolution. The protein consists of three structural domains with the oligonucleotide lying in a groove between the first two domains and the third. The first two domains have an adenylate kinase like fold, including a phosphate-binding loop in the first domain. CONCLUSIONS: HCV NS3 helicase is a member of a superfamily of helicases, termed superfamily II. Residues of NS3 helicase which are conserved among superfamily II helicases line an interdomain cleft between the first two domains. The oligonucleotide binds in an orthogonal binding site and contacts relatively few conserved residues. There are no strong sequence-specific interactions with the oligonucleotide bases.


Assuntos
DNA de Cadeia Simples/química , Hepacivirus/enzimologia , Sequência de Aminoácidos , Sequência Conservada/genética , Cristalografia por Raios X , Modelos Moleculares , Dados de Sequência Molecular , Conformação de Ácido Nucleico , Conformação Proteica , Dobramento de Proteína , Estrutura Secundária de Proteína , Proteínas de Ligação a RNA/fisiologia , Alinhamento de Sequência , Proteínas não Estruturais Virais , Proteínas Virais/química
14.
Structure ; 7(6): 651-61, 1999 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-10404594

RESUMO

BACKGROUND: The lymphocyte-specific kinase Lck is a member of the Src family of non-receptor tyrosine kinases. Lck catalyzes the initial phosphorylation of T-cell receptor components that is necessary for signal transduction and T-cell activation. On the basis of both biochemical and genetic studies, Lck is considered an attractive cell-specific target for the design of novel T-cell immunosuppressants. To date, the lack of detailed structural information on the mode of inhibitor binding to Lck has limited the discovery of novel Lck inhibitors. RESULTS: We report here the high-resolution crystal structures of an activated Lck kinase domain in complex with three structurally distinct ATP-competitive inhibitors: AMP-PNP (a non-selective, non-hydrolyzable ATP analog); staurosporine (a potent but non-selective protein kinase inhibitor); and PP2 (a potent Src family selective protein tyrosine kinase inhibitor). Comparison of these structures reveals subtle but important structural changes at the ATP-binding site. Furthermore, PP2 is found to access a deep, hydrophobic pocket near the ATP-binding cleft of the enzyme; this binding pocket is not occupied by either AMP-PNP or staurosporine. CONCLUSIONS: The potency of staurosporine against Lck derives in part from an induced movement of the glycine-rich loop of the enzyme upon binding of this ligand, which maximizes the van der Waals interactions present in the complex. In contrast, PP2 binds tightly and selectively to Lck and other Src family kinases by making additional contacts in a deep, hydrophobic pocket adjacent to the ATP-binding site; the amino acid composition of this pocket is unique to Src family kinases. The structures of these Lck complexes offer useful structural insights as they demonstrate that kinase selectivity can be achieved with small-molecule inhibitors that exploit subtle topological differences among protein kinases.


Assuntos
Inibidores Enzimáticos/química , Proteína Tirosina Quinase p56(lck) Linfócito-Específica/química , Linfócitos/enzimologia , Quinases da Família src/antagonistas & inibidores , Trifosfato de Adenosina/química , Adenilil Imidodifosfato/química , Sequência de Aminoácidos , Cristalografia por Raios X , Humanos , Ligação de Hidrogênio , Modelos Moleculares , Dados de Sequência Molecular , Estrutura Molecular , Fosfotirosina/metabolismo , Ligação Proteica , Piridinas/química , Alinhamento de Sequência , Estaurosporina/química
15.
Radiat Prot Dosimetry ; 119(1-4): 293-9, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16644972

RESUMO

The thermoluminescence (TL) emission spectra from LiF TL materials, called KLT-300 (LiF:Mg,Cu,Na,Si) with various dopant concentrations are measured and analysed. These KLT-300 materials were developed by the Korea Atomic Energy Research Institute (KAERI) to achieve an enhancement of the thermal stability in TL readings. Six types of samples are prepared with different dopant concentrations in the following ranges; Mg (0-0.20 mol%), Cu (0-0.05 mol%), Na and Si (0-0.9 mol%). The spectra measurements are carried out for the six types of samples using a TL emission spectra measurement device. The spectra measurement device consists of a monochromator, photomultiplier tube and temperature control unit to thermally stimulate the samples. The measured data shows the light emission during heating of the sample as a function of temperature and wavelength (three-dimensional TL spectra). The spectra were analysed using a method of deconvolution based on gaussian curve. The wavelength of a main peak of the emission spectra changes depending on the existence of the Cu dopant, while intensity of the spectra rapidly changes with the Cu dopant concentrations. The 385 nm emission is mainly observed in all the spectra from the samples with the Cu dopant, but in those from the samples without the Cu dopant a very weak 401 nm emission is mainly observed. However, any change in the wavelength at a main peak of the TL emission spectra from the sample materials with Na and Si dopants is not observed but that in the intensity at a peak of the spectra is observed.


Assuntos
Cobre/química , Fluoretos/química , Fluoretos/efeitos da radiação , Compostos de Lítio/química , Compostos de Lítio/efeitos da radiação , Magnésio/química , Silício/química , Sódio/química , Dosimetria Termoluminescente/instrumentação , Técnicas de Química Combinatória , Cobre/efeitos da radiação , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Magnésio/efeitos da radiação , Teste de Materiais , Doses de Radiação , Silício/efeitos da radiação , Sódio/efeitos da radiação , Dosimetria Termoluminescente/métodos
16.
Radiat Prot Dosimetry ; 119(1-4): 510-3, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16644954

RESUMO

The MCNPX code has been employed on a personal computer to calculate the dosimetric characteristics of the photon beams from the 6 MV Siemens MX2 and the 10 MV Varian Clinac 2100C linear accelerators. A model of the treatment head includes the major geometric structure within the beam path. The model was used to calculate the energy spectra of the photon beam, percentage depth dose and the dose profiles. The accuracy of the calculated results is examined by comparing them with the measured dose distributions for the two machines. The computed and measured depth dose curves agree to within 2% for all the depths beyond the build-up region for both treatment machines. The calculations agree to within 2% of the measured profiles within the 100-50% dose level. It has been found that the MCNPX code is an effective tool for simulating the clinical photon beam.


Assuntos
Modelos Biológicos , Método de Monte Carlo , Aceleradores de Partículas/instrumentação , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/métodos , Carga Corporal (Radioterapia) , Humanos , Modelos Estatísticos , Fótons/uso terapêutico , Dosagem Radioterapêutica , Eficiência Biológica Relativa
17.
Radiat Prot Dosimetry ; 119(1-4): 353-6, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16644960

RESUMO

The energy responses for the KLT-300(LiF:Mg,Cu,Na,Si, Korea), GR-200(LiF:Mg,Cu,P, China) and MCP-N(LiF:Mg,Cu,P, Poland) thermoluminescence(TL) pellets were studied for a photon radiation with energies from 1.25 MeV(60Co) to 21 MV (Microtron) to verify the usefulness of the calibration for the radiotherapy beams. The International Atomic Energy Agency (IAEA) and the World Health Organization (WHO) have performed thermoluminescence dosimetry (TLD) audits to verify the calibration of the beams by TL powder, but TL pellets were used in this study because the element correction factor (ECF), defined as the factor to correct the variations that all TL dosemeters cannot be manufactured to have exactly the same TL efficiency, for each TL pellet could be accurately derived and be handled conveniently when compared with the powder. Also several works for the energy response of the TLDs were done for the low-energy photon beams up to 60Co, but they will be extended in this experiment to the high photon energies (up to 20 MV), which are widely used in the therapy level of a radiation. The PTW 30006 ionisation chamber was calibrated by the Korea primary standards to establish the air-kerma rates and the TL pellets were irradiated in a specially designed waterproof pellet holder in a water phantom (30 x 30 x 30 cm3) just like the IAEA postal audits programme. This result was compared with that of another type of phantom [10 (W) x 10 (L) x 10 (H) cm3 PMMA Perspex phantom for the 60Co and 6 MV photon, and 10 x 10 x 20 (H) cm3 for the 10 and 21 MV photon] for its convenient use and easy handling and installation in a hospital. The results show that the differences of the responses for the water phantom and PMMA Perspex phantom were negligible, which is contrary to the general conception that a big difference would be expected. For an application of these results to verify the therapy beams, an appropriate energy correction factor should be applied to the energies and phantom types in use.


Assuntos
Fluoretos/química , Fluoretos/efeitos da radiação , Transferência Linear de Energia , Compostos de Lítio/química , Compostos de Lítio/efeitos da radiação , Modelos Químicos , Fótons , Dosimetria Termoluminescente/instrumentação , Dosimetria Termoluminescente/métodos , Simulação por Computador , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Doses de Radiação
18.
Radiat Prot Dosimetry ; 119(1-4): 15-22, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16644968

RESUMO

Measurements of the response of thermoluminescent (TL) detectors after gamma ray doses high enough to observe signal saturation provide input to microdosimetric models which relate this gamma-ray response with the energy response after low doses of photons (gamma rays and low-energy X rays) and after high-LET irradiation. To measure their gamma ray response up to saturation, LiF:Mg,Ti (MTS-7 and MTT), LiF:Mg,Cu,P (MCP-7), CaSO4:Dy (KCD) and Al2O3:C detectors were irradiated with 60Co gamma rays over the range 1-5000 Gy. The X-ray photon energy response and TL efficiency (relative to gamma rays) after doses of beta rays and alpha particles, were also measured, for CaSO4:Dy and for Al2O3:C. Microdosimetric and track structure modelling was then applied to the experimental data. In a manner similar to LiF:Mg,Cu,P, the experimentally observed under response of alpha-Al2O3:C to X rays <100 keV, compared with cross-section calculations, is explained as a microdosimetric effect caused by the saturation of response of this detector without prior supralinearity (saturation of traps along the tracks). The enhanced X-ray photon energy response of CaSO4:Dy is related to the supralinearity observed in this material after high gamma ray doses, similarly to that in LiF:Mg,Ti. The discussed model approaches support the general rule relating dose-, energy- and ionisation density-responses in TL detectors: if their gamma ray response is sublinear prior to saturation, the measured photon energy response is lower, and if it is supralinear, it may be higher than that expected from the calculation of the interaction cross sections alone. Since similar rules have been found to apply to other solid-state detector systems, microdosimetry may offer a valuable contribution to solid-state dosimetry even prior to mechanistic explanations of physical phenomena in different TL detectors.


Assuntos
Transferência Linear de Energia , Modelos Teóricos , Dosimetria Termoluminescente/instrumentação , Simulação por Computador , Desenho Assistido por Computador , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Raios gama , Fótons , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dosimetria Termoluminescente/métodos
19.
Curr Top Microbiol Immunol ; 242: 171-96, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-10592661

RESUMO

Hepatitis C Virus helicase activity has been mapped to the COOH-terminal 450 residues of the NS3 protein. Due to its complexity and presumed essentiality for viral replication, the helicase is an attractive target for drug discovery. The elucidation of the atomic structure of the HCV NS3 helicase in complex with oligonucleotide and with ADP has helped clarify our understanding of potential sites for inhibitor binding. Molecular details of the mechanism of this enzyme, and in particular, a better understanding of the mechanism by which ATP hydrolysis is coupled to unwinding of double-stranded substrate may facilitate more efficient structure-based drug design.


Assuntos
Hepacivirus/enzimologia , RNA Helicases/metabolismo , Proteínas não Estruturais Virais/metabolismo , Sequência de Aminoácidos , Antivirais , Sequência Conservada , Desenho de Fármacos , Modelos Moleculares , Estrutura Terciária de Proteína , RNA Helicases/antagonistas & inibidores , RNA Helicases/química , RNA Viral/metabolismo , Proteínas não Estruturais Virais/antagonistas & inibidores , Proteínas não Estruturais Virais/química
20.
Radiat Prot Dosimetry ; 115(1-4): 340-4, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16381743

RESUMO

In this paper, some results of the study on the roles of the dopants in the LiF:Mg,Cu,Na,Si thermoluminescent (TL) material that was developed at the Korea Atomic Energy Research Institute for radiation protection are presented. Although there have been many studies to investigate the roles of the dopants in LiF:Mg,Cu,P TL material in the TL process, there are some discrepancies in the understanding of the roles of Cu and P between various researchers. In case of LiF:Mg,Cu,Na,Si TL material, there are a few studies on the roles of the dopants. Three kinds of samples in each of which one dopant is excluded, and the optimised sample, were prepared for this study. The measurements and analysis of the three-dimensional TL spectra, based on the temperature, wavelength and intensity, and the glow curves for those samples are used in this study. The results show that Mg plays a role in the trapping of the charge carriers and Cu plays a role in the luminescence recombination process; however, the effect of Na and Si on the glow curve structure and the TL emission spectra is much less than that of Mg and Cu. It is considered that Na and Si each plays a role in the improvement of the luminescence efficiency.


Assuntos
Fluoretos/química , Fluoretos/efeitos da radiação , Transferência Linear de Energia/efeitos da radiação , Compostos de Lítio/química , Compostos de Lítio/efeitos da radiação , Metais/química , Metais/efeitos da radiação , Proteção Radiológica/instrumentação , Dosimetria Termoluminescente/instrumentação , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Fótons , Doses de Radiação , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dosimetria Termoluminescente/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA