Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Oral Health ; 24(1): 750, 2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-38943102

RESUMO

BACKGROUND: Iatrogenic mandibular nerve damage resulting from oral surgeries and dental procedures is painful and a formidable challenge for patients and oral surgeons alike, mainly because the absence of objective and quantitative methods for diagnosing nerve damage renders treatment and compensation ambiguous while often leading to medico-legal disputes. The aim of this study was to examine discriminating factors of traumatic mandibular nerve within a specific magnetic resonance imaging (MRI) protocol and to suggest tangible diagnostic criteria for peripheral trigeminal nerve injury. METHODS: Twenty-six patients with ipsilateral mandibular nerve trauma underwent T2 Flex water, 3D short tau inversion recovery (STIR), and diffusion-weighted imaging (DWI) acquired by periodically rotating overlapping parallel lines with enhanced reconstruction (PROPELLER) pulse sequences; 26 injured nerves were thus compared with contra-lateral healthy nerves at anatomically corresponding sites. T2 Flex apparent signal to noise ratio (FSNR), T2 Flex apparent nerve-muscle contrast to noise ratio (FNMCNR) 3D STIR apparent signal to noise ratio (SSNR), 3D STIR apparent nerve-muscle contrast to noise ratio (SNMCNR), apparent diffusion coefficient (ADC) and area of cross-sectional nerve (Area) were evaluated. RESULTS: Mixed model analysis revealed FSNR and FNMCNR to be the dual discriminators for traumatized mandibular nerve (p < 0.05). Diagnostic performance of both parameters was also determined with area under the receiver operating characteristic curve (AUC for FSNR = 0.712; 95% confidence interval [CI]: 0.5660, 0.8571 / AUC for FNMCNR = 0.7056; 95% confidence interval [CI]: 1.011, 1.112). CONCLUSIONS: An increase in FSNR and FNMCNR within our MRI sequence seems to be accurate indicators of the presence of traumatic nerve. This prospective study may serve as a foundation for sophisticated model diagnosing trigeminal nerve trauma within large patient cohorts.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Imageamento por Ressonância Magnética/métodos , Traumatismos do Nervo Mandibular/diagnóstico por imagem , Imageamento Tridimensional/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Nervo Mandibular/diagnóstico por imagem , Idoso , Adulto Jovem , Traumatismos do Nervo Trigêmeo/diagnóstico por imagem , Razão Sinal-Ruído
2.
Opt Express ; 31(26): 43877-43890, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-38178473

RESUMO

Spinal endoscopy procedure is commonly used in the diagnosis and treatment of various health problems and is effective. Bleeding is one of the most common complications of spinal endoscopy procedures. Blood vision obstruction (BVO), that is, obstruction of the endoscopic camera lens caused by the accumulation of blood in the surgical field, is a serious problem in endoscopic procedures. This study presents what we believe to be a new approach to addressing BVO with external multispectral imaging. The study was completed using a BVO simulation model, and the results reveal that this technology can be used to effectively overcome BVO and provide clear images of the anatomy, enabling more effective diagnosis and treatment. This technique may enable improvement of the outcomes of endoscopic procedures and could have far-reaching implications in the field of endoscopy.


Assuntos
Diagnóstico por Imagem , Endoscopia , Endoscopia/métodos , Simulação por Computador
3.
Neurospine ; 21(2): 474-486, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38955525

RESUMO

Artificial intelligence (AI) is transforming spinal imaging and patient care through automated analysis and enhanced decision-making. This review presents a clinical task-based evaluation, highlighting the specific impact of AI techniques on different aspects of spinal imaging and patient care. We first discuss how AI can potentially improve image quality through techniques like denoising or artifact reduction. We then explore how AI enables efficient quantification of anatomical measurements, spinal curvature parameters, vertebral segmentation, and disc grading. This facilitates objective, accurate interpretation and diagnosis. AI models now reliably detect key spinal pathologies, achieving expert-level performance in tasks like identifying fractures, stenosis, infections, and tumors. Beyond diagnosis, AI also assists surgical planning via synthetic computed tomography generation, augmented reality systems, and robotic guidance. Furthermore, AI image analysis combined with clinical data enables personalized predictions to guide treatment decisions, such as forecasting spine surgery outcomes. However, challenges still need to be addressed in implementing AI clinically, including model interpretability, generalizability, and data limitations. Multicenter collaboration using large, diverse datasets is critical to advance the field further. While adoption barriers persist, AI presents a transformative opportunity to revolutionize spinal imaging workflows, empowering clinicians to translate data into actionable insights for improved patient care.

4.
Neurosurg Focus Video ; 10(2): V8, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38616900

RESUMO

Ganglioneuroma (GN) is a rare solid neoplasm developing from neural crest cells of sympathetic ganglia or adrenal medulla. It usually presents as an asymptomatic mass in the retroperitoneal space and mediastinum. Resection through open surgery or minimal access is recommended. The video illustrates the case of a 23-year-old female with an incidental finding of thoracic GN. The authors performed a combined, staged approach to ensure complete resection, which involved unilateral T3-4 biportal endoscopy (UBE) for rhizotomy and nerve root decompression, followed by video-assisted thoracoscopic surgery (VATS) for complete excision. The procedure was uneventful, with full recovery and no postoperative complications. The video can be found here: https://stream.cadmore.media/r10.3171/2024.2.FOCVID23210.

5.
Neurosurg Focus Video ; 10(2): V4, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38616902

RESUMO

An 84-year-old woman presented with left leg radiating pain for 18 months and a numeric rating scale score of 8. From examination, motoric on left knee extension was grade 4, with dysesthesia and numbness along the left anterolateral thigh. Imaging showed left L3-4 foraminal and lateral recess stenosis with severe-degree scoliosis. The patient underwent navigation-guided endoscopic transforaminal foraminotomy and lateral recess decompression on the left L3-4 level with a good outcome. Three-years' follow-up showed a well-maintained clinical outcome and coronal sagittal balance. This video explores navigation-guided endoscopic lumbar decompression for neural compression in advanced scoliosis. Further research is encouraged to establish long-term efficacy. The video can be found here: https://stream.cadmore.media/r10.3171/2024.1.FOCVID23195.

6.
J Neurosurg Case Lessons ; 8(8)2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39159496

RESUMO

BACKGROUND: In recent developments, full endoscopic and unilateral biportal endoscopic (UBE) spine surgery have emerged to aid the transforaminal lumbar interbody fusion (TLIF) procedure. Yet, both approaches present a challenge due to limited space for cage insertion, potentially leading to complications such as cage subsidence or nonfusion in long-term assessments. Utilizing double cages may mitigate these concerns. This paper presents a unique case in which a patient successfully underwent computed tomography (CT) navigation-guided UBE-TLIF with 2 converging cages, highlighting the potential benefits and feasibility of this innovative approach. OBSERVATIONS: A 59-year-old female diagnosed with degenerative spondylolisthesis at the L4-5 level underwent a UBE-TLIF. The operation is detailed step by step and supported by illustrative figures and surgical videos. Postsurgery results revealed a significant improvement in the patient's condition, with the visual analog scale score decreasing from 7 to 3 on the first day, leading to a satisfaction rate of 90% at the last follow-up. LESSONS: Utilizing endoscopic visualization complemented by contrast medium has substantially elevated the quality of disc preparation. From their observations, the authors affirm that the integration of intraoperative CT navigation systems significantly augments safety and pinpoint accuracy in UBE-TLIF procedures. The strategy of employing 2 converging cages through a unilateral technique stands as a practical solution, potentially optimizing the fusion outcomes of UBE-TLIF surgery. https://thejns.org/doi/10.3171/CASE23512.

7.
Adv Radiat Oncol ; 9(6): 101478, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38681894

RESUMO

Purpose: Despite the increasing interest in using continuous positive airway pressure (CPAP) in radiation therapy (RT), direct comparisons with the more widely used deep inspiration breath-hold (DIBH) have been limited. This planning study aimed to offer comprehensive geometric and dosimetric evidence by comparing CPAP and DIBH-based RT plans. Materials and Methods: A retrospective data set of 35 patients with left-sided breast cancer with planning computed tomography scans under three breathing conditions (free breathing (FB), CPAP with 10 cmH2O pressure, and DIBH) was collected. Volumetric arc therapy plans aimed for 95% dose coverage to 95% of the planning target volume with a maximum dose below 107%. A comparative dosimetric analysis among the three plans was conducted. Additionally, geometric differences were assessed by calculating the minimum distance between the heart and the clinical target volume (CTV) in each planning computed tomography. Results: CPAP and DIBH plans demonstrated comparable mean heart doses (1.05 Gy), which were significantly lower than the FB plan (1.34 Gy). The maximum dose to the left anterior descending artery was smallest in the CPAP plan (4.44 Gy), followed by DIBH (4.73 Gy) and FB (7.33 Gy) plans. Other organ-at-risk doses for CPAP and DIBH were similar, with mean contralateral breast doses of 2.27 and 2.21 Gy, mean ipsilateral lung doses of 4.09 and 4.08 Gy, V20 at 6.11% and 6.31%, and mean contralateral lung doses of 0.94 and 0.92 Gy, respectively. No significant difference was found in the minimum heart-to-CTV distance between CPAP and DIBH. DIBH exhibited the greatest lung volume (3908 cc), followed by CPAP (3509 cc), and FB(2703 cc). Conclusions: The comparison between CPAP and DIBH shows their similarity in both geometric and dosimetric aspects, providing strong evidence for CPAP's effectiveness and feasibility in RT. This suggests its potential as an alternative to DIBH for patients with left-sided breast cancer.

8.
Clin Transl Radiat Oncol ; 45: 100734, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38317677

RESUMO

Purpose: We aimed to develop Lyman-Kutcher-Burman (LKB) and multivariable normal tissue complication probability (NTCP) models to predict the risk of radiation-induced hypothyroidism (RIHT) in breast cancer patients. Materials and methods: A total of 1,063 breast cancer patients who underwent whole breast irradiation between 2009 and 2016 were analyzed. Individual dose-volume histograms were used to generate LKB and multivariable logistic regression models. LKB model was fit using the thyroid radiation dose-volume parameters. A multivariable model was constructed to identify potential dosimetric and clinical parameters associated with RIHT. Internal validation was conducted using bootstrapping techniques, and model performance was evaluated using the area under the curve (AUC) and Hosmer-Lemeshow (HL) goodness-of-fit test. Results: RIHT developed in 4 % of patients with a median follow-up of 77.7 months. LKB and multivariable NTCP models exhibited significant agreement between the predicted and observed results (HL P values > 0.05). The multivariable NTCP model outperformed the LKB model in predicting RIHT (AUC 0.62 vs. 0.54). In the multivariable model, systemic therapy, age, and percentage of thyroid volume receiving ≥ 10 Gy (V10) were significant prognostic factors for RIHT. The cumulative incidence of RIHT was significantly higher in patients who exceeded the cut-off values for all three risk predictors (systemic therapy, age ≥ 40 years, and thyroid V10 ≥ 26 %, P < 0.005). Conclusions: Systemic therapy, age, and V10 of the thyroid were identified as strong risk factors for the development of RIHT. Our NTCP models provide valuable insights to clinicians for predicting and preventing hypothyroidism by identifying high-risk patients.

9.
Phys Eng Sci Med ; 47(2): 443-451, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38224383

RESUMO

With the increasing use of flattening filter free (FFF) beams, it is important to evaluate the impact on the skin dose and target coverage of breast cancer treatments. This study aimed to compare skin doses of treatments using FFF and flattening filter (FF) beams for breast cancer. The study established treatment plans for left breast of an anthropomorphic phantom using Halcyon's 6-MV FFF beam and TrueBeam's 6-MV FF beam. Volumetric modulated arc therapy (VMAT) with varying numbers of arcs and intensity modulated radiation therapy (IMRT) were employed, and skin doses were measured at five points using Gafchromic EBT3 film. Each measurement was repeated three times, and averaged to reduce uncertainty. All plans were compared in terms of plan quality to ensure homogeneous target coverage. The study found that when using VMAT with two, four, and six arcs, in-field doses were 19%, 15%, and 6% higher, respectively, when using Halcyon compared to TrueBeam. Additionally, when using two arcs for VMAT, in-field doses were 10% and 15% higher compared to four and six arcs when using Halcyon. Finally, in-field dose from Halcyon using IMRT was about 1% higher than when using TrueBeam. Our research confirmed that when treating breast cancer with FFF beams, skin dose is higher than with traditional FF beams. Moreover, number of arcs used in VMAT treatment with FFF beams affects skin dose to the patient. To maintain a skin dose similar to that of FF beams when using Halcyon, it may be worth considering increasing the number of arcs.


Assuntos
Neoplasias da Mama , Aceleradores de Partículas , Imagens de Fantasmas , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada , Pele , Humanos , Pele/efeitos da radiação , Feminino , Neoplasias da Mama/radioterapia , Mama/efeitos da radiação , Mama/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador , Relação Dose-Resposta à Radiação , Doses de Radiação
10.
Phys Med Biol ; 69(11)2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38663411

RESUMO

Objective. Deep-learning networks for super-resolution (SR) reconstruction enhance the spatial-resolution of 3D magnetic resonance imaging (MRI) for MR-guided radiotherapy (MRgRT). However, variations between MRI scanners and patients impact the quality of SR for real-time 3D low-resolution (LR) cine MRI. In this study, we present a personalized super-resolution (psSR) network that incorporates transfer-learning to overcome the challenges in inter-scanner SR of 3D cine MRI.Approach: Development of the proposed psSR network comprises two-stages: (1) a cohort-specific SR (csSR) network using clinical patient datasets, and (2) a psSR network using transfer-learning to target datasets. The csSR network was developed by training on breath-hold and respiratory-gated high-resolution (HR) 3D MRIs and their k-space down-sampled LR MRIs from 53 thoracoabdominal patients scanned at 1.5 T. The psSR network was developed through transfer-learning to retrain the csSR network using a single breath-hold HR MRI and a corresponding 3D cine MRI from 5 healthy volunteers scanned at 0.55 T. Image quality was evaluated using the peak-signal-noise-ratio (PSNR) and the structure-similarity-index-measure (SSIM). The clinical feasibility was assessed by liver contouring on the psSR MRI using an auto-segmentation network and quantified using the dice-similarity-coefficient (DSC).Results. Mean PSNR and SSIM values of psSR MRIs were increased by 57.2% (13.8-21.7) and 94.7% (0.38-0.74) compared to cine MRIs, with the reference 0.55 T breath-hold HR MRI. In the contour evaluation, DSC was increased by 15% (0.79-0.91). Average time consumed for transfer-learning was 90 s, psSR was 4.51 ms per volume, and auto-segmentation was 210 ms, respectively.Significance. The proposed psSR reconstruction substantially increased image and segmentation quality of cine MRI in an average of 215 ms across the scanners and patients with less than 2 min of prerequisite transfer-learning. This approach would be effective in overcoming cohort- and scanner-dependency of deep-learning for MRgRT.


Assuntos
Imageamento Tridimensional , Imagem Cinética por Ressonância Magnética , Humanos , Imagem Cinética por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Radioterapia Guiada por Imagem/métodos , Aprendizado Profundo
11.
Sci Rep ; 14(1): 10719, 2024 05 10.
Artigo em Inglês | MEDLINE | ID: mdl-38729975

RESUMO

The shielding parameters can vary depending on the geometrical structure of the linear accelerators (LINAC), treatment techniques, and beam energies. Recently, the introduction of O-ring type linear accelerators is increasing. The objective of this study is to evaluate the shielding parameters of new type of linac using a dedicated program developed by us named ORSE (O-ring type Radiation therapy equipment Shielding Evaluation). The shielding evaluation was conducted for a total of four treatment rooms including Elekta Unity, Varian Halcyon, and Accuray Tomotherapy. The developed program possesses the capability to calculate transmitted dose, maximum treatable patient capacity, and shielding wall thickness based on patient data. The doses were measured for five days using glass dosimeters to compare with the results of program. The IMRT factors and use factors obtained from patient data showed differences of up to 65.0% and 33.8%, respectively, compared to safety management report. The shielding evaluation conducted in each treatment room showed that the transmitted dose at every location was below 1% of the dose limit. The results of program and measurements showed a maximum difference of 0.003 mSv/week in transmitted dose. The ORSE program allows for the shielding evaluation results to the clinical environment of each institution based on patient data.


Assuntos
Aceleradores de Partículas , Proteção Radiológica , Aceleradores de Partículas/instrumentação , Proteção Radiológica/instrumentação , Proteção Radiológica/métodos , Humanos , Radioterapia de Intensidade Modulada/métodos , Doses de Radiação
12.
Phys Med ; 123: 103414, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38906047

RESUMO

PURPOSE: This study reviewed and meta-analyzed evidence on radiomics-based hybrid models for predicting radiation pneumonitis (RP). These models are crucial for improving thoracic radiotherapy plans and mitigating RP, a common complication of thoracic radiotherapy. We examined and compared the RP prediction models developed in these studies with the radiomics features employed in RP models. METHODS: We systematically searched Google Scholar, Embase, PubMed, and MEDLINE for studies published up to April 19, 2024. Sixteen studies met the inclusion criteria. We compared the RP prediction models developed in these studies and the radiomics features employed. RESULTS: Radiomics, as a single-factor evaluation, achieved an area under the receiver operating characteristic curve (AUROC) of 0.73, accuracy of 0.69, sensitivity of 0.64, and specificity of 0.74. Dosiomics achieved an AUROC of 0.70. Clinical and dosimetric factors showed lower performance, with AUROCs of 0.59 and 0.58. Combining clinical and radiomic factors yielded an AUROC of 0.78, while combining dosiomic and radiomics factors produced an AUROC of 0.81. Triple combinations, including clinical, dosimetric, and radiomics factors, achieved an AUROC of 0.81. The study identifies key radiomics features, such as the Gray Level Co-occurrence Matrix (GLCM) and Gray Level Size Zone Matrix (GLSZM), which enhance the predictive accuracy of RP models. CONCLUSIONS: Radiomics-based hybrid models are highly effective in predicting RP. These models, combining traditional predictive factors with radiomic features, particularly GLCM and GLSZM, offer a clinically feasible approach for identifying patients at higher RP risk. This approach enhances clinical outcomes and improves patient quality of life. PROTOCOL REGISTRATION: The protocol of this study was registered on PROSPERO (CRD42023426565).


Assuntos
Pneumonite por Radiação , Humanos , Pneumonite por Radiação/diagnóstico por imagem , Pneumonite por Radiação/etiologia , Radiômica
13.
Adv Radiat Oncol ; 9(1): 101319, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38260220

RESUMO

Purpose: Recently developed online adaptive radiation therapy (OnART) systems enable frequent treatment plan adaptation, but data supporting a dosimetric benefit in postoperative head and neck radiation therapy (RT) are sparse. We performed an in silico dosimetric study to assess the potential benefits of a single versus weekly OnART in the treatment of patients with head and neck squamous cell carcinoma in the adjuvant setting. Methods and Materials: Twelve patients receiving conventionally fractionated RT over 6 weeks and 12 patients receiving hypofractionated RT over 3 weeks on a clinical trial were analyzed. The OnART emulator was used to virtually adapt either once midtreatment or weekly based on the patient's routinely performed cone beam computed tomography. The planning target volume (PTV) coverage, dose heterogeneity, and cumulative dose to the organs at risk for these 2 adaptive approaches were compared with the nonadapted plan. Results: In total, 13, 8, and 3 patients had oral cavity, oropharynx, and larynx primaries, respectively. In the conventionally fractionated RT cohort, weekly OnART led to a significant improvement in PTV V100% coverage (6.2%), hot spot (-1.2 Gy), and maximum cord dose (-3.1 Gy), whereas the mean ipsilateral parotid dose increased modestly (1.8 Gy) versus the nonadapted plan. When adapting once midtreatment, PTV coverage improved with a smaller magnitude (0.2%-2.5%), whereas dose increased to the ipsilateral parotid (1.0-1.1 Gy) and mandible (0.2-0.7 Gy). For the hypofractionated RT cohort, similar benefit was observed with weekly OnART, including significant improvement in PTV coverage, hot spot, and maximum cord dose, whereas no consistent dosimetric advantage was seen when adapting once midtreatment. Conclusions: For head and neck squamous cell carcinoma adjuvant RT, there was a limited benefit of single OnART, but weekly adaptations meaningfully improved the dosimetric criteria, predominantly PTV coverage and dose heterogeneity. A prospective study is ongoing to determine the clinical benefit of OnART in this setting.

14.
Radiother Oncol ; 191: 110066, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38142936

RESUMO

PURPOSE: To analyze the dosimetric and toxicity outcomes of patients treated with postoperative stereotactic partial breast irradiation (S-PBI). METHODS: We identified 799 women who underwent S-PBI at our institution between January 2016 and December 2022. The most commonly used dose-fraction and technique were 30 Gy in 5 fractions (91.7 %) and a robotic stereotactic radiation system with real-time tracking (83.7 %). The primary endpoints were dosimetric parameters and radiation-related toxicities. For comparison, a control group undergoing ultra-hypofractionated whole breast irradiation (UF-WBI, n = 468) at the same institution was selected. RESULTS: A total of 815 breasts from 799 patients, with a median planning target volume (PTV) volume of 89.6 cm3, were treated with S-PBI. Treatment plans showed that the mean and maximum doses received by the PTV were 96.2 % and 104.8 % of the prescription dose, respectively. The volume of the ipsilateral breast that received 50 % of the prescription dose was 32.3 ± 8.9 %. The mean doses for the ipsilateral lung and heart were 2.5 ± 0.9 Gy and 0.65 ± 0.39 Gy, respectively. Acute toxicity occurred in 175 patients (21.5 %), predominantly of grade 1. Overall rate of late toxicity was 4 % with a median follow-up of 31.6 months. Compared to the UF-WBI group, the S-PBI group had comparably low acute toxicity (21.5 % vs. 25.2 %, p = 0.12) but significantly lower dosimetric parameters for all organs-at-risks (all p < 0.05). CONCLUSION: In this large cohort, S-PBI demonstrated favorable dosimetric and toxicity profiles. Considering the reduced radiation exposure to surrounding tissues, external beam PBI with advanced techniques should at least be considered over traditional WBI-based approaches for PBI candidates.


Assuntos
Neoplasias da Mama , Lesões por Radiação , Radioterapia Conformacional , Feminino , Humanos , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Radiometria , Mama/efeitos da radiação , Radioterapia Conformacional/métodos , Dosagem Radioterapêutica , Mastectomia Segmentar
15.
Int J Surg ; 2024 Aug 08.
Artigo em Inglês | MEDLINE | ID: mdl-39116451

RESUMO

BACKGROUND: The increasing use of kidneys from elderly donors raises concerns due to age-related nephron loss. Combined with nephrectomy, this loss of nephrons markedly increases the risk of developing chronic kidney disease (CKD). This study aimed to investigate the prognostic value of preoperative kidney cortex volume in predicting the loss of kidney function in elderly donors, by developing an artificial intelligence (AI)-based model for precise kidney volume measurement and applying it to living kidney donors. MATERIALS METHODS: A multicenter retrospective cohort study using data from living donors who underwent donor nephrectomy between January 2010 and December 2020 was conducted. An AI segmentation model was developed and validated to measure kidney cortex volume from pre-donation computer tomographic (CT) images. The association between measured preoperative kidney volumes and post-nephrectomy renal function was analyzed through a generalized additive model. RESULTS: A total of 1074 living kidney donors were included in the study. Validation of the developed kidney cortex volume model showed a Dice similarity coefficient of 0.97 and a Hausdorff distance of 0.76 mm. The measured cortex volumes exhibited an age-related decrease, which correlated with declining kidney function. Elderly donors showed greater decreases in estimated glomerular filtration rates (eGFR) post-donation compared to young donors (P=0.041). Larger preoperative remnant kidney cortex volume was associated with significantly less decline of eGFR post-donation than those with smaller preoperative remnant kidney cortex volume (P<0.001). CONCLUSION: This study highlights the critical role of preoperative kidney cortex volume in the donor assessment process, particularly for elderly donors. The fully automated model for measuring kidney cortex volume provides a valuable tool for predicting post-donation renal function and holds promise for enhancing donor evaluation and safety.

16.
Sci Rep ; 14(1): 7134, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532018

RESUMO

We aimed to investigate the deliverability of dynamic conformal arc therapy (DCAT) by gantry wobble owing to the intrinsic inter-segment break of the Elekta linear accelerator (LINAC) and its adverse influence on the dose to the patient. The deliverability of DCAT was evaluated according to the plan parameters, which affect the gantry rotation speed and resultant positional inaccuracies; the deliverability according to the number of control points and dose rates was investigated by using treatment machine log files and dosimetry devices, respectively. A non-negligible degradation in DCAT deliverability due to gantry wobble was observed in both the treatment machine log files and dosimetry devices. The resulting dose-delivery error occurred below a certain number of control points or above a certain dose rate. Dose simulations in the patient domain showed a similar impact on deteriorated deliverability. For targets located primarily in the isocenter, the dose differences were negligible, whereas for organs at risk located mainly off-isocenter, the dose differences were significant up to - 8.77%. To ensure safe and accurate radiotherapy, optimal plan parameters should be selected, and gantry angle-specific validations should be conducted before treatment.


Assuntos
Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Aceleradores de Partículas , Radiometria/métodos , Radioterapia de Intensidade Modulada/métodos
17.
PLoS One ; 19(4): e0301435, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38635642

RESUMO

In radiotherapy, when photon energy exceeding 8 MV is utilized, photoneutrons can activate the components within the gantry of the linear accelerator (linac). At the end of the linac's lifecycle, radiation workers are tasked with its dismantling and disposal, potentially exposing them to unintentional radiation. This study aims to identify and measure the radioisotopes generated by this activation through spectroscopy, and to evaluate the effective dose rate. We selected nine medical linacs, considering various factors such as manufacturer (Siemens, Varian, and Elekta), model, energy, period of operation, and workload. We identified the radionuclides in the linac head by employing an in situ high-purity germanium (HPGe) detector. Spectroscopy and dose-rate measurements were conducted post-shutdown. We also measured the dose rates at the beam-exit window following irradiation with 10 MV and 15 MV photon beams. As a result of the spectroscopy, we identified approximately 20 nuclides including those with half-lives of 100 days or longer, such as 54Mn, 60Co, 65Zn, 122Sb, and 198Au. The dose rate measurements after 10 MV irradiation decreased to the background level in 10 min. By contrast, on 15 MV irradiation, the dose rate was 628 nSv/h after 10 min and decreased to 268 nSv/h after 1.5 hours. It was confirmed that the difference in the level of radiation and the type of nuclide depends on the period of use, energy, and workload. However, the type of nuclide does not differ significantly between the linacs. It is necessary to propose appropriate guidelines for the safety of workers, and disposal/move-install should be planned while taking into consideration the equipment's energy usage rate.


Assuntos
Manganês , Radioisótopos , Humanos , Dosagem Radioterapêutica , Aceleradores de Partículas , Fótons , Análise Espectral
18.
Med Phys ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38978162

RESUMO

BACKGROUND: Intensity modulation with dynamic multi-leaf collimator (MLC) and monitor unit (MU) changes across control points (CPs) characterizes volumetric modulated arc therapy (VMAT). The increased uncertainty in plan deliverability required patient-specific quality assurance (PSQA), which remained inefficient upon Quality Assurance (QA) failure. To prevent waste before QA, plan complexity metrics (PCMs) and machine learning models with the metrics were generated, which were lack of providing CP-specific information upon QA failures. PURPOSE: By generating 3D images from digital imaging and comminications in medicine in radiation therapy (DICOM RT) plan, we proposed a predictive model that can estimate the deliverability of VMAT plans and visualize CP-specific regions associated with plan deliverability. METHODS: The patient cohort consisted of 259 and 190 cases for left- and right-breast VMAT treatments, which were split into 235 and 166 cases for training and 24 cases from each treatment for testing the networks. Three-channel 3D images generated from DICOM RT plans were fed into a DenseNet-based deep learning network. To reflect VMAT plan complexity as an image, the first two channels described MLC and MU variations between two consecutive CPs, while the last channel assigned the beam field size. The network output was defined as binary classified PSQA results, indicating deliverability. The predictive performance was assessed by accuracy, sensitivity, specificity, F1-score, and area under the curve (AUC). The gradient-weighted class activation map (Grad-CAM) highlighted the regions of CPs in VMAT plans associated with deliverability, compared against PCMs by Spearman correlation. RESULTS: The DenseNet-based predictive model yielded AUCs of 92.2% and 93.8%, F1-scores of 97.0% and 93.8% and accuracies of 95.8% and 91.7% for the left- and right-breast VMAT cases. Additionally, the specificity of 87.5% for both cases indicated that the predictive model accurately detected QA failing cases. The activation maps significantly differentiated QA failing-labeled from passing-labeled classes for the non-deliverable cases. The PCM with the highest correlation to the Grad-CAM varied from patient cases, implying that plan deliverability would be considered patient-specific. CONCLUSION: This work demonstrated that the deep learning-based network based on visualization of dynamic VMAT plan information successfully predicted plan deliverability, which also provided control-point specific planning parameter information associated with plan deliverability in a patient-specific manner.

19.
Phys Med Biol ; 69(11)2024 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-38759672

RESUMO

Objective.This study aimed to develop a new approach to predict radiation dermatitis (RD) by using the skin dose distribution in the actual area of RD occurrence to determine the predictive dose by grade.Approach.Twenty-three patients with head and neck cancer treated with volumetric modulated arc therapy were prospectively and retrospectively enrolled. A framework was developed to segment the RD occurrence area in skin photography by matching the skin surface image obtained using a 3D camera with the skin dose distribution. RD predictive doses were generated using the dose-toxicity surface histogram (DTH) calculated from the skin dose distribution within the segmented RD regions classified by severity. We then evaluated whether the developed DTH-based framework could visually predict RD grades and their occurrence areas and shapes according to severity.Main results.The developed framework successfully generated the DTH for three different RD severities: faint erythema (grade 1), dry desquamation (grade 2), and moist desquamation (grade 3); 48 DTHs were obtained from 23 patients: 23, 22, and 3 DTHs for grades 1, 2, and 3, respectively. The RD predictive doses determined using DTHs were 28.9 Gy, 38.1 Gy, and 54.3 Gy for grades 1, 2, and 3, respectively. The estimated RD occurrence area visualized by the DTH-based RD predictive dose showed acceptable agreement for all grades compared with the actual RD region in the patient. The predicted RD grade was accurate, except in two patients.Significance. The developed DTH-based framework can classify and determine RD predictive doses according to severity and visually predict the occurrence area and shape of different RD severities. The proposed approach can be used to predict the severity and shape of potential RD in patients and thus aid physicians in decision making.


Assuntos
Radiodermite , Humanos , Radiodermite/etiologia , Masculino , Feminino , Pessoa de Meia-Idade , Radioterapia de Intensidade Modulada/efeitos adversos , Neoplasias de Cabeça e Pescoço/radioterapia , Idoso , Dosagem Radioterapêutica , Índice de Gravidade de Doença , Doses de Radiação , Pele/efeitos da radiação , Pele/diagnóstico por imagem , Pele/patologia
20.
Radiother Oncol ; 198: 110410, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38917883

RESUMO

BACKGROUND AND PURPOSE: To promote the development of auto-segmentation methods for head and neck (HaN) radiation treatment (RT) planning that exploit the information of computed tomography (CT) and magnetic resonance (MR) imaging modalities, we organized HaN-Seg: The Head and Neck Organ-at-Risk CT and MR Segmentation Challenge. MATERIALS AND METHODS: The challenge task was to automatically segment 30 organs-at-risk (OARs) of the HaN region in 14 withheld test cases given the availability of 42 publicly available training cases. Each case consisted of one contrast-enhanced CT and one T1-weighted MR image of the HaN region of the same patient, with up to 30 corresponding reference OAR delineation masks. The performance was evaluated in terms of the Dice similarity coefficient (DSC) and 95-percentile Hausdorff distance (HD95), and statistical ranking was applied for each metric by pairwise comparison of the submitted methods using the Wilcoxon signed-rank test. RESULTS: While 23 teams registered for the challenge, only seven submitted their methods for the final phase. The top-performing team achieved a DSC of 76.9 % and a HD95 of 3.5 mm. All participating teams utilized architectures based on U-Net, with the winning team leveraging rigid MR to CT registration combined with network entry-level concatenation of both modalities. CONCLUSION: This challenge simulated a real-world clinical scenario by providing non-registered MR and CT images with varying fields-of-view and voxel sizes. Remarkably, the top-performing teams achieved segmentation performance surpassing the inter-observer agreement on the same dataset. These results set a benchmark for future research on this publicly available dataset and on paired multi-modal image segmentation in general.


Assuntos
Neoplasias de Cabeça e Pescoço , Imageamento por Ressonância Magnética , Órgãos em Risco , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Imageamento por Ressonância Magnética/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Órgãos em Risco/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA