Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
1.
J Clin Monit Comput ; 37(2): 409-420, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36149575

RESUMO

We recently developed a model-based method for analyzing multiple breath nitrogen washout data that does not require identification of Phase-III. In the present study, we assessed the effect of irregular breathing patterns on the intra-subject variabilities of the model parameters. Nitrogen fraction at the mouth was measured in 18 healthy and 20 asthmatic subjects during triplicate performances of multiple breath nitrogen washout, during controlled (target tidal volume 1 L at 8-12 breaths per minute) and free (unrestricted) breathing. The parameters Scond, Sacin and functional residual capacity (FRC) were obtained by conventional analysis of the slope of Phase-III. Fitting the model to the washout data provided functional residual capacity (FRCM), dead space volume (VD), the coefficient of variation of regional specific ventilation ([Formula: see text]), and the model equivalent of Sacin (Sacin-M). Intra-participant coefficients of variation for the model parameters for both health and asthma were FRCM < 5.2%, VD < 5.4%, [Formula: see text] < 9.0%, and Sacin-M < 45.6% for controlled breathing, and FRCM < 4.6%, VD < 5.3%, [Formula: see text] < 13.2%, and Sacin-M < 103.2% for free breathing. The coefficients of variation limits for conventional parameters were FRC < 6.1%, with Scond < 73.6% and Sacin < 49.2% for controlled breathing and Scond < 35.0% and Sacin < 74.4% for free breathing. The model-fitting approach to multiple breath nitrogen washout analysis provides a measure of regional ventilation heterogeneity in [Formula: see text] that is less affected by irregularities in the breathing pattern than its corresponding Phase-III slope analysis parameter Scond.


Assuntos
Asma , Nitrogênio , Humanos , Testes de Função Respiratória/métodos , Pulmão , Respiração
2.
Environ Res ; 214(Pt 1): 113860, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35820650

RESUMO

The small size and large surface area of ultrafine particles (UFP) enhance their ability to deposit in the lung periphery and their reactivity. The Ultrafine Particles from Traffic Emissions and Children's Health (UPTECH) cross-sectional study was conducted in 8-11-year-old schoolchildren attending 25 primary (elementary) schools, randomly selected from the Brisbane Metropolitan Area, Queensland, Australia. Main study findings outlined indirect evidence of distal airway deposition (raised C reactive protein) but as yet, there is no direct evidence in the literature of effects of UFP exposure on peripheral airway function. We present further UPTECH study data from two sensitive peripheral airway function tests, Oscillometry and Multiple Breath Nitrogen Washout (MBNW), performed in 577 and 627 children (88% and 96% of UPTECH study cohort) respectively: mean(SD) age 10.1(0.9) years, 46% male, with 50% atopy and 14% current asthma. Bayesian generalised linear mixed effects regression models were used to estimate the effect of UFP particle number count (PNC) exposure on key oscillometry (airway resistance, (Rrs), and reactance, (Xrs)) and MBNW (lung clearance index, (LCI) and functional residual capacity, (FRC)) indices. We adjusted for age, sex, and height, and potential confounders including socio-economic disadvantage, PM2.5 and NO2 exposure. All models contained an interaction term between UFP PNC exposure and atopy, allowing estimation of the effect of exposure on non-atopic and atopic students. Increasing UFP PNC was associated with greater lung stiffness as evidenced by a decrease in Xrs [mean (95% credible interval) -1.63 (-3.36 to -0.05)%] per 1000#.cm-3]. It was also associated with greater lung stiffness (decrease in Xrs) in atopic subjects across all models [mean change ranging from -2.06 to -2.40% per 1000#.cm-3]. A paradoxical positive effect was observed for Rrs across all models [mean change ranging from -1.55 to -1.70% per 1000#.cm-3] (decreases in Rrs indicating an increase in airway calibre), which was present for both atopic and non-atopic subjects. No effects on MBNW indices were observed. In conclusion, a modest detrimental effect of UFP on peripheral airway function among atopic subjects, as assessed by respiratory system reactance, was observed extending the main UPTECH study findings which reported a positive association with a biomarker for systemic inflammation, C-reactive protein (CRP). Further studies are warranted to explore the pathophysiological mechanisms underlying increased respiratory stiffness, and whether it persists through to adolescence and adulthood.


Assuntos
Poluentes Atmosféricos , Material Particulado , Poluentes Atmosféricos/efeitos adversos , Teorema de Bayes , Biomarcadores , Criança , Estudos Transversais , Feminino , Humanos , Masculino , Tamanho da Partícula , Material Particulado/efeitos adversos
3.
BMC Pulm Med ; 22(1): 211, 2022 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-35643452

RESUMO

BACKGROUND: There is increasing evidence of small airway abnormalities in smokers despite normal spirometry. The concavity in the descending limb of the maximum expiratory flow curve (MEFV) is a recognised feature of obstruction and can provide information beyond FEV1, and potentially early smoking-related damage. We aimed to evaluate concavity measures compared to known small airway measurements. METHODS: Eighty smokers with normal spirometry had small airway function assessed: multiple breath nitrogen washout (MBNW) from which ventilation heterogeneity in the diffusion-dependent acinar (Sacin) and convection-dependent conductive (Scond) airways were assessed, and impulse oscillometry system (IOS) from which respiratory resistance and reactance at 5 Hz (R5 and X5) were measured. Concavity measures were calculated from the MEFV, partitioned into global and peripheral concavity. RESULTS: We found abnormal peripheral and global concavity as well as acinar ventilation heterogeneity are common in "normal" smokers. Concavity measures were not related to either MBNW or IOS measurements. CONCLUSION: Abnormalities in concavity indices and MBNW or oscillometry parameters are common in smokers despite normal spirometry. However, these measures likely reflect different mechanisms of peripheral airway dysfunction.


Assuntos
Pulmão , Fumantes , Humanos , Oscilometria , Pirina , Testes de Função Respiratória , Espirometria
4.
Respirology ; 26(6): 566-573, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33797141

RESUMO

BACKGROUND AND OBJECTIVE: Asthma guidelines emphasize the importance of assessing lung function and symptoms. The forced oscillation technique (FOT) and its longitudinal relationship with spirometry and symptoms are unresolved. We examined concordance between longitudinal spirometry, FOT and symptom control, and determined FOT limits of agreement in stable asthma. METHODS: Over a 3-year period, adults with asthma attending a tertiary clinic completed the asthma control test (ACT), fraction of exhaled nitric oxide (FeNO), FOT and spirometry. Analysis included between-visit concordance for significant change using Cohen's kappa (κ) and stable asthma FOT limits of agreement. RESULTS: Data (n = 186) from 855 visits (mean ± SD 4.6 ± 3.0 visits), 114 ± 95 days apart, were analysed. Between-visit concordance was moderate between reactance at 5 Hz (X5) and forced expiratory volume in 1 s (FEV1 ) (κ = 0.34, p = 0.001), and weak between ACT and FEV1 (κ = 0.18, p = 0.001). Change in FeNO did not correlate with lung function or ACT (κ < 0.05, p > 0.1). Stable asthma between visits (n = 75; 132 visits) had reduced lung function variability, but comparable concordance to the entire cohort. Limits of agreement for FEV1 (0.42 L), resistance at 5 Hz (2.06 cm H2 O s L-1 ) and X5 (2.75 cm H2 O s L-1 ) in stable asthma were at least twofold greater than published values in health. CONCLUSION: In adults with asthma, there is moderate concordance between longitudinal change in FOT and spirometry. Both tests relate poorly to changes in asthma control, highlighting the need for multi-modal assessment in asthma rather than symptoms alone. The derivation of longitudinal FOT limits of agreement will assist in its clinical interpretation.


Assuntos
Asma , Adulto , Asma/diagnóstico , Volume Expiratório Forçado , Humanos , Oscilometria/métodos , Testes de Função Respiratória , Espirometria/métodos
5.
Intern Med J ; 51(2): 169-180, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32104958

RESUMO

Severe asthma imposes a significant burden on individuals, families and the healthcare system. Treatment is complex, due to disease heterogeneity, comorbidities and complexity in care pathways. New approaches and treatments improve health outcomes for people with severe asthma. However, emerging multidimensional and targeted treatment strategies require a reorganisation of asthma care. Consensus is required on how reorganisation should occur and what areas require further research. The Centre of Excellence in Severe Asthma convened three forums between 2015 and 2018, hosting experts from Australia, New Zealand and the UK. The forums were complemented by a survey of clinicians involved in the management of people with severe asthma. We sought to: (i) identify areas of consensus among experts; (ii) define activities and resources required for the implementation of findings into practice; and (iii) identify specific priority areas for future research. Discussions identified areas of unmet need including assessment and diagnosis of severe asthma, models of care and treatment pathways, add-on treatment approaches and patient perspectives. We recommend development of education and training activities, clinical resources and standards of care documents, increased stakeholder engagement and public awareness campaigns and improved access to infrastructure and funding. Further, we propose specific future research to inform clinical decision-making and develop novel therapies. A concerted effort is required from all stakeholders (including patients, healthcare professionals and organisations and government) to integrate new evidence-based practices into clinical care and to advance research to resolve questions relevant to improving outcomes for people with severe asthma.


Assuntos
Asma , Asma/diagnóstico , Asma/epidemiologia , Asma/terapia , Austrália/epidemiologia , Comorbidade , Humanos , Nova Zelândia/epidemiologia , Organizações
6.
Eur Respir J ; 56(3)2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32430416

RESUMO

BACKGROUND: Telemonitoring trials for early detection of acute exacerbations of chronic obstructive pulmonary disease (AECOPD) have provided mixed results. Day-to-day variations in lung function measured by the forced oscillation technique (FOT) may yield greater insight. We evaluated the clinical utility of home telemonitoring of variability in FOT measures in terms of 1) the relationship with symptoms and quality of life (QoL); and 2) the timing of variability of FOT measures and symptom changes prior to AECOPD. METHODS: Daily FOT parameters at 5 Hz (resistance (R) and reactance (X); Resmon Pro Diary, Restech Srl, Milan, Italy), daily symptoms (COPD Assessment Test (CAT)) and 4-weekly QoL data (St George's Respiratory Questionnaire (SGRQ)) were recorded over 8-9 months from chronic obstructive pulmonary disease (COPD) patients. Variability of R and X was calculated as the standard deviation (sd) over 7-day running windows and we also examined the effect of varying window size. The relationship of FOT versus CAT and SGRQ was assessed using linear mixed modelling, daily changes in FOT variability and CAT prior to AECOPD using one-way repeated measures ANOVA. RESULTS: Fifteen participants with a mean±sd age of 69±10 years and a % predicted forced expiratory volume in 1 s (FEV1) of 39±10% had a median (interquartile range (IQR)) adherence of 95.4% (79.0-98.8%). Variability of the inspiratory component of X (indicated by the standard deviation of inspiratory reactance (SDXinsp)) related to CAT and weakly to SGRQ (fixed effect estimates 1.57, 95% CI 0.65-2.49 (p=0.001) and 4.41, 95% CI -0.06 to 8.89 (p=0.05), respectively). SDXinsp changed significantly on the same day as CAT (1 day before AECOPD, both p=0.02) and earlier when using shorter running windows (3 days before AECOPD, p=0.01; accuracy=0.72 for 5-day windows). CONCLUSIONS: SDXinsp from FOT telemonitoring reflects COPD symptoms and may be a sensitive biomarker for early detection of AECOPD.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Qualidade de Vida , Volume Expiratório Forçado , Humanos , Itália , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Testes de Função Respiratória
7.
Eur Respir J ; 55(2)2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31772002

RESUMO

Oscillometry (also known as the forced oscillation technique) measures the mechanical properties of the respiratory system (upper and intrathoracic airways, lung tissue and chest wall) during quiet tidal breathing, by the application of an oscillating pressure signal (input or forcing signal), most commonly at the mouth. With increased clinical and research use, it is critical that all technical details of the hardware design, signal processing and analyses, and testing protocols are transparent and clearly reported to allow standardisation, comparison and replication of clinical and research studies. Because of this need, an update of the 2003 European Respiratory Society (ERS) technical standards document was produced by an ERS task force of experts who are active in clinical oscillometry research.The aim of the task force was to provide technical recommendations regarding oscillometry measurement including hardware, software, testing protocols and quality control.The main changes in this update, compared with the 2003 ERS task force document are 1) new quality control procedures which reflect use of "within-breath" analysis, and methods of handling artefacts; 2) recommendation to disclose signal processing, quality control, artefact handling and breathing protocols (e.g. number and duration of acquisitions) in reports and publications to allow comparability and replication between devices and laboratories; 3) a summary review of new data to support threshold values for bronchodilator and bronchial challenge tests; and 4) updated list of predicted impedance values in adults and children.


Assuntos
Pulmão , Respiração , Adulto , Testes de Provocação Brônquica , Broncodilatadores , Criança , Humanos , Oscilometria
8.
Respirology ; 25(8): 827-835, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32026586

RESUMO

BACKGROUND AND OBJECTIVE: Abnormal peripheral airway function is an important feature of asthma and relates to asthma symptoms and poor asthma control. We aimed to determine whether peripheral airway function, as measured by forced oscillatory impedance and multiple-breath nitrogen washout (MBNW), relates to symptom improvement in asthmatic participants with uncontrolled asthma, after stepping up to high-dose ICS/LABA treatment. METHODS: A total of 19 subjects (14 females, mean age: 29.9 ± 13.6 years) with uncontrolled asthma, as defined by an ACQ5 > 1.5, taking 500 µg/day fluticasone equivalent or less, underwent spirometry, plethysmography, fractional exhaled FeNO, forced oscillatory resistance (Rrs5Hz ) and reactance (Xrs5Hz ), and indices of MBNW ventilation heterogeneity (lung clearance index (LCI), diffusion-convection-dependent (Sacin) and convection-dependent (Scond)). Measurements were made before and after 8 weeks of treatment with fluticasone/formoterol combination inhaler 250/10 µg, 2 puffs twice daily. RESULTS: Treatment improved ACQ5 (P = 0.0002), FEV1 (P = 0.02), FVC (P = 0.04), FeNO (P = 0.0008), Xrs5Hz (P = 0.01), LCI (P = 0.0002), Sacin (P = 0.006) and Scond (P = 0.01). At baseline, ACQ5 correlated with Xrs5Hz (rs = 0.52, P = 0.03) and Rrs5Hz (rs = 0.55, P = 0.02). The improvement in ACQ5 was predicted by more abnormal baseline LCI (P = 0.03), Scond (P = 0.02) and Rrs5Hz (P = 0.006). Baseline Scond was the best predictor of a clinically meaningful improvement in asthma control (ΔACQ > 0.5, ROC-AUC = 0.91, P = 0.007). CONCLUSION: Step-up to high-dose combination treatment in uncontrolled asthma is associated with improved peripheral airway function as measured by Xrs5Hz and MBNW. Baseline MBNW and FOT parameters correlated with the improvement in symptoms and may predict a positive response to up-titration in uncontrolled asthmatic patients.


Assuntos
Asma/tratamento farmacológico , Asma/prevenção & controle , Oscilometria , Ventilação Pulmonar , Administração por Inalação , Corticosteroides/administração & dosagem , Corticosteroides/uso terapêutico , Agonistas de Receptores Adrenérgicos beta 2/uso terapêutico , Adulto , Asma/fisiopatologia , Combinação de Medicamentos , Feminino , Fluticasona/administração & dosagem , Fluticasona/farmacologia , Fluticasona/uso terapêutico , Fumarato de Formoterol/administração & dosagem , Fumarato de Formoterol/farmacologia , Fumarato de Formoterol/uso terapêutico , Humanos , Pulmão/efeitos dos fármacos , Pulmão/fisiopatologia , Masculino , Nitrogênio/metabolismo , Ventilação Pulmonar/efeitos dos fármacos , Curva ROC , Respiração , Testes de Função Respiratória , Espirometria
9.
Respirology ; 25(6): 613-619, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31482693

RESUMO

BACKGROUND AND OBJECTIVE: Fixed airflow obstruction (FAO) in asthma occurs despite optimal inhaled treatment and no smoking history, and remains a significant problem, particularly with increasing age and duration of asthma. Increased lung compliance and loss of lung elastic recoil has been observed in older people with asthma, but their link to FAO has not been established. We determined the relationship between abnormal lung elasticity and airflow obstruction in asthma. METHODS: Non-smoking asthmatic subjects aged >40 years, treated with 2 months of high-dose inhaled corticosteroid/long-acting beta-agonist (ICS/LABA), had FAO measured by spirometry, and respiratory system resistance at 5 Hz (Rrs5 ) and respiratory system reactance at 5 Hz (Xrs5 ) measured by forced oscillation technique. Lung compliance (K) and elastic recoil (B/A) were calculated from pressure-volume curves measured by an oesophageal balloon. Linear correlations between K and B/A, and forced expiratory volume in 1 s/forced vital capacity (FEV1 /FVC), Rrs5 and Xrs5 were assessed. RESULTS: Eighteen subjects (11 males; mean ± SD age: 64 ± 8 years, asthma duration: 39 ± 22 years) had moderate FAO measured by spirometry ((mean ± SD z-score) post-bronchodilator FEV1 : -2.2 ± 0.5, FVC: -0.7 ± 1.0, FEV1 /FVC: -2.6 ± 0.7) and by increased Rrs5 (median (IQR) z-score) 2.7 (1.9 to 3.2) and decreased Xrs5 : -4.1(-2.4 to -7.3). Lung compliance (K) was increased in 9 of 18 subjects and lung elastic recoil (B/A) reduced in 5 of 18 subjects. FEV1 /FVC correlated negatively with K (rs = -0.60, P = 0.008) and Rrs5 correlated negatively with B/A (rs = -0.52, P = 0.026), independent of age. Xrs5 did not correlate with lung elasticity indices. CONCLUSION: Increased lung compliance and loss of elastic recoil relate to airflow obstruction in older non-smoking asthmatic subjects, independent of ageing. Thus, structural lung tissue changes may contribute to persistent, steroid-resistant airflow obstruction. CLINICAL TRIAL REGISTRATION: ACTRN126150000985583 at anzctr.org.au (UTN: U1111-1156-2795).


Assuntos
Corticosteroides/uso terapêutico , Asma/tratamento farmacológico , Volume Expiratório Forçado/fisiologia , Complacência Pulmonar/fisiologia , Capacidade Vital/fisiologia , Idoso , Asma/patologia , Elasticidade/efeitos dos fármacos , Feminino , Humanos , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica , Testes de Função Respiratória/métodos , Espirometria/métodos
10.
Thorax ; 73(1): 82-84, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28866642

RESUMO

In adult patients with cystic fibrosis (CF), the lung clearance index (LCI) derived from the multiple breath washout relates to both acinar and conductive ventilation heterogeneity. The latter component predicts an association between LCI and the number of bronchial segments affected by bronchiectasis. Here, we experimentally demonstrated this association in patients with CF, and also examined an ancillary group of patients with non-CF bronchiectasis. We conclude that lung disease severity in terms of number of bronchial segments results in an associated LCI increase, likely constituting a portion of LCI that cannot be reversed by treatment in patients with CF lung disease.


Assuntos
Bronquiectasia/fisiopatologia , Fibrose Cística/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Bronquiectasia/etiologia , Estudos de Casos e Controles , Fibrose Cística/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Depuração Mucociliar/fisiologia , Testes de Função Respiratória
11.
Eur Respir J ; 52(2)2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29946002

RESUMO

Chronic mucus hypersecretion (CMH) contributes to the morbidity and mortality of asthma, and remains uncontrolled by current therapies in the subset of patients with severe, steroid-resistant disease. Altered cross-talk between airway epithelium and airway smooth muscle cells (ASMCs), driven by pro-inflammatory cytokines such as interleukin (IL)-1ß, provides a potential mechanism that influences CMH. This study investigated mechanisms underlying CMH by comparing IL-1ß-induced gene expression profiles between asthma and control-derived ASMCs and the subsequent paracrine influence on airway epithelial mucus production in vitroIL-1ß-treated ASMCs from asthmatic patients and healthy donors were profiled using microarray analysis and ELISA. Air-liquid interface (ALI)-cultured CALU-3 and primary airway epithelial cells were treated with identified candidates and mucus production assessed.The IL-1ß-induced CCL20 expression and protein release was increased in ASMCs from moderate compared with mild asthmatic patients and healthy controls. IL-1ß induced lower MIR146A expression in asthma-derived ASMCs compared with controls. Decreased MIR146A expression was validated in vivo in bronchial biopsies from 16 asthmatic patients versus 39 healthy donors. miR-146a-5p overexpression abrogated CCL20 release in ASMCs. CCL20 treatment of ALI-cultured CALU-3 and primary airway epithelial cells induced mucus production, while CCL20 levels in sputum were associated with increased levels of CMH in asthmatic patients.Elevated CCL20 production by ASMCs, possibly resulting from dysregulated expression of the anti-inflammatory miR-146a-5p, may contribute to enhanced mucus production in asthma.


Assuntos
Asma/metabolismo , Quimiocina CCL20/metabolismo , Interleucina-1beta/farmacologia , MicroRNAs/metabolismo , Miócitos de Músculo Liso/metabolismo , Adolescente , Adulto , Idoso , Asma/tratamento farmacológico , Estudos de Casos e Controles , Células Cultivadas , Células Epiteliais/efeitos dos fármacos , Células Epiteliais/metabolismo , Feminino , Expressão Gênica , Humanos , Masculino , Pessoa de Meia-Idade , Muco/metabolismo , Miócitos de Músculo Liso/efeitos dos fármacos , Escarro/metabolismo , Adulto Jovem
12.
Respirology ; 23(3): 262-271, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29316003

RESUMO

Severe asthma is defined by the high treatment requirements to partly or fully control the clinical manifestations of disease. It remains a problem worldwide with a large burden for individuals and health services. The key to improving targeted treatments, reducing disease burden and improving patient outcomes is a better understanding of the pathophysiology and mechanisms of severe disease. The heterogeneity, complexity and difficulties in undertaking clinical studies in severe asthma remain challenges to achieving better understanding and better outcomes. In this review, we focus on the structural, mechanical and inflammatory abnormalities that are relevant in severe asthma.


Assuntos
Remodelação das Vias Aéreas/fisiologia , Asma/fisiopatologia , Broncoconstrição/fisiologia , Fluxo Expiratório Forçado/fisiologia , Asma/diagnóstico , Humanos , Índice de Gravidade de Doença
13.
Respirology ; 23(5): 512-518, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29141272

RESUMO

BACKGROUND AND OBJECTIVE: Smokers develop respiratory symptoms and peripheral airway dysfunction even when spirometry is preserved. Multiple breath nitrogen washout (MBNW) and impulse oscillometry system (IOS) are potentially useful measures of peripheral airway function but they have not been compared in such subjects. We hypothesized that MBNW and IOS are jointly abnormal in smokers with normal spirometry and that these abnormalities relate to respiratory symptoms. METHODS: Eighty smokers with normal spirometry completed a symptom questionnaire, had ventilation heterogeneity in diffusion (Sacin) and convection-dependent (Scond) airways and trapped gas volume at functional residual capacity as a percentage of vital capacity (%VtrFRC/VC) measured by MBNW. Respiratory resistance and reactance at 5 and 20 Hz were measured using IOS. RESULTS: Respiratory symptoms were reported in 55 (68%) subjects. Forty (50%) subjects had at least one abnormal MBNW parameter, predominantly in Sacin. Forty-one (51%) subjects had at least one abnormal IOS parameter, predominantly in resistance. Sixty-one (76%) subjects had an abnormality in either MBNW or IOS. Chronic bronchitis symptoms were associated with an increased Scond, while wheeze was associated with lower spirometry and an increased resistance. Abnormalities in MBNW and IOS parameters were unrelated to each other. CONCLUSIONS: Respiratory symptoms and peripheral airway dysfunction are common in smokers with normal spirometry. Symptoms of chronic bronchitis related to conductive airway abnormalities, while wheeze was related to spirometry and IOS. The clinical significance of abnormalities in peripheral airway function in smokers remains undetermined.


Assuntos
Bronquite Crônica/fisiopatologia , Pulmão/fisiopatologia , Fumar/fisiopatologia , Adulto , Resistência das Vias Respiratórias , Feminino , Capacidade Residual Funcional , Humanos , Masculino , Oscilometria , Estudos Prospectivos , Capacidade de Difusão Pulmonar , Sons Respiratórios , Espirometria , Inquéritos e Questionários , Avaliação de Sintomas , Volume de Ventilação Pulmonar
14.
COPD ; 15(4): 341-349, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29799289

RESUMO

Hyperinflation, gas trapping and their responses to long-acting bronchodilator are clinically important in COPD. The forced oscillation technique (FOT) measures of respiratory system resistance and reactance are sensitive markers of bronchodilator response in COPD. The relationships between changes in resistance and reactance, and changes in hyperinflation and gas trapping, following long-acting bronchodilator (LA-BD) have not been studied. 15 subjects with mild-moderate COPD underwent FOT, spirometry then body plethysmography, before and 2 hours after a single 150 microg dose of the LA-BD indacaterol. Hyperinflation was quantified as the inspiratory capacity to total lung capacity ratio (IC/TLC), and gas trapping as residual volume to TLC ratio (RV/TLC). At baseline, FOT parameters were moderately correlated with IC/TLC (|r| 0.53-0.73, p < 0.05). At 2 hours post-LA-BD, there were moderate correlations between change in FOT and change in RV/TLC (|r| 0.60-0.82, p < 0.05). Baseline FOT parameters also correlated with the subsequent post-LA-BD change in both IC/TLC (|r| 0.54-0.62, p < 0.05) and RV/TLC (|r| 0.57-0.76, p < 0.05). FOT impedance reflects hyperinflation and gas trapping in COPD, and the potential for long-acting bronchodilator responsiveness. These results provide us with further insight into the physiological mechanisms of action of long-acting bronchodilator treatment, and may be clinically useful for predicting treatment responses.


Assuntos
Broncodilatadores/uso terapêutico , Indanos/uso terapêutico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Quinolonas/uso terapêutico , Idoso , Resistência das Vias Respiratórias/efeitos dos fármacos , Broncodilatadores/farmacologia , Técnicas de Diagnóstico do Sistema Respiratório , Feminino , Volume Expiratório Forçado/efeitos dos fármacos , Humanos , Indanos/farmacologia , Masculino , Pessoa de Meia-Idade , Oscilometria , Pletismografia Total , Capacidade de Difusão Pulmonar/efeitos dos fármacos , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Quinolonas/farmacologia , Volume Residual/efeitos dos fármacos , Índice de Gravidade de Doença , Espirometria , Capacidade Pulmonar Total/efeitos dos fármacos
16.
J Clin Monit Comput ; 32(3): 509-512, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28761996

RESUMO

The forced oscillation technique (FOT) is an emerging clinical lung function test, with commercial devices becoming increasingly available. However comparability across existing devices has not been established. We evaluated in vivo and in vitro measurements made using three commercial devices against a custom-built device (WIMR): Resmon Pro Diary (Restech srl, Italy), tremoFlo C-100 (Thorasys Medical Systems, Canada), Jaeger Masterscope CT IOS (CareFusion, Hoechberg, Germany). Respiratory system resistance Rrs and reactance Xrs at 5 Hz were examined in twelve healthy subjects (mean age 33 ± 11 years, 7 males), and in two test standards of known resistance and reactance. Subjects performed three measurements during tidal breathing on the four devices in random order. Total, inspiratory and expiratory Rrs and Xrs were calculated and compared using one-way repeated measures ANOVA and Bonferroni post-hoc tests. Rrs did not differ between devices, with <10% deviation from predicted, except for the IOS device. With Xrs, similar values were seen between the WIMR and Resmon devices and between the tremoFlo and IOS devices. No differences were observed using test standards; deviation from theoretical value was <2% for resistance and <5% for reactance. The WIMR, tremoFlo and Resmon Pro but not IOS devices measure similar Rrs, whereas there was more disparity across devices in the estimation of Xrs parameters. The discrepancy between in vivo and in vitro measurements suggest that FOT validation procedures need to take into account the breathing pattern, either using biological controls or a breathing model.


Assuntos
Desenho de Equipamento , Oscilometria/métodos , Testes de Função Respiratória/instrumentação , Testes de Função Respiratória/métodos , Adulto , Feminino , Voluntários Saudáveis , Humanos , Técnicas In Vitro , Masculino , Monitorização Fisiológica , Reprodutibilidade dos Testes , Respiração , Processamento de Sinais Assistido por Computador , Software , Adulto Jovem
17.
Am J Physiol Lung Cell Mol Physiol ; 312(3): L348-L357, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-27941076

RESUMO

Force adaptation, a process whereby sustained spasmogenic activation (viz., tone) of airway smooth muscle (ASM) increases its contractile capacity, has been reported in isolated ASM tissues in vitro, as well as in mice in vivo. The objective of the present study was to assess the effect of tone on airway responsiveness in humans. Ten healthy volunteers underwent methacholine challenge on two occasions. One challenge consisted of six serial doses of saline followed by a single high dose of methacholine. The other consisted of six low doses of methacholine 5 min apart followed by a higher dose. The cumulative dose was identical for both challenges. After both methacholine challenges, subjects took a deep inspiration (DI) to total lung capacity as another way to probe ASM mechanics. Responses to methacholine and the DI were measured using a multifrequency forced oscillation technique. Compared with a single high dose, the challenge preceded by tone led to an elevated response measured by respiratory system resistance (Rrs) and reactance at 5 Hz. However, there was no difference in the increase in Rrs at 19 Hz, suggesting a predominant effect on smaller airways. Increased tone also reduced the efficacy of DI, measured by an attenuated maximal dilation during the DI and an increased renarrowing post-DI. We conclude that ASM tone increases small airway responsiveness to inhaled methacholine and reduces the effectiveness of DI in healthy humans. This suggests that force adaptation may contribute to airway hyperresponsiveness and the reduced bronchodilatory effect of DI in asthma.


Assuntos
Saúde , Pulmão/fisiopatologia , Tono Muscular , Músculo Liso/fisiopatologia , Hipersensibilidade Respiratória/fisiopatologia , Adulto , Brônquios/efeitos dos fármacos , Feminino , Humanos , Inalação , Masculino , Cloreto de Metacolina/farmacologia , Tono Muscular/efeitos dos fármacos , Músculo Liso/efeitos dos fármacos , Oscilometria , Mecânica Respiratória/efeitos dos fármacos , Espirometria , Adulto Jovem
19.
Respirology ; 22(6): 1110-1117, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28397998

RESUMO

BACKGROUND AND OBJECTIVE: Peripheral airway involvement in asthma remains poorly understood. We investigated impulse oscillometry (IOS) measures of peripheral airway function in a population-based birth cohort. METHODS: Pre- and post-bronchodilator spirometry and IOS measures of respiratory resistance and reactance were measured in 915 participants at age 38 years. RESULTS: Current asthma was associated with impairments in both spirometry and IOS parameters. These impairments were greater in men and in those with childhood persistent asthma. Spirometry and IOS values for those whose asthma was in remission were not different to non-asthmatic participants. There were significant changes in IOS in both asthmatic and non-asthmatic participants after bronchodilator, but between-group differences persisted. Higher BMIs were associated with impairments in IOS but not spirometry. Cumulative tobacco use was associated with spirometric airflow obstruction in both sexes, whereas cannabis use was associated with impairments in IOS in women. Despite higher lifetime exposure, there were few associations between cannabis and IOS in men. CONCLUSION: Asthma is associated with abnormalities in IOS measures of peripheral airway dysfunction. This association is stronger in men and in those with asthma persisting since childhood. Tobacco and cannabis use are associated with different patterns of spirometry and IOS abnormalities and may affect the bronchial tree at different airway generations with differences in susceptibility between sexes.


Assuntos
Asma/fisiopatologia , Broncodilatadores/farmacologia , Fumar Maconha/fisiopatologia , Oscilometria , Fumar Tabaco/fisiopatologia , Adulto , Resistência das Vias Respiratórias , Índice de Massa Corporal , Broncoconstrição , Estudos de Casos e Controles , Estudos de Coortes , Feminino , Humanos , Masculino , Fatores Sexuais , Espirometria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA