Detalhe da pesquisa
1.
Examining electrometer performance checks with direct-current generator in a clinic: Assessment of generated charges and implementation of electrometer checks.
J Appl Clin Med Phys
; 22(7): 306-312, 2021 Jul.
Artigo
em Inglês
| MEDLINE | ID: mdl-34085364
2.
Uncertainty in positioning ion chamber at reference depth for various water phantoms.
Rep Pract Oncol Radiother
; 23(3): 199-206, 2018.
Artigo
em Inglês
| MEDLINE | ID: mdl-29760594
3.
Comparison of AAPM Addendum to TG-51, IAEA TRS-398, and JSMP 12: Calibration of photon beams in water.
J Appl Clin Med Phys
; 18(5): 271-278, 2017 Sep.
Artigo
em Inglês
| MEDLINE | ID: mdl-28771919
4.
[2. Treatment Facility Response to Separate Calibration of Radiotherapy Dosimeter].
Nihon Hoshasen Gijutsu Gakkai Zasshi
; 75(5): 507-511, 2019.
Artigo
em Japonês
| MEDLINE | ID: mdl-31105102
5.
[Uncertainty of cross calibration-applied beam quality conversion factor for the Japan Society of Medical Physics 12].
Nihon Hoshasen Gijutsu Gakkai Zasshi
; 70(9): 877-82, 2014 Sep.
Artigo
em Japonês
| MEDLINE | ID: mdl-25242596
6.
[A comparison of absorbed doses to water in photon beams in Japan Society of Medical Physics 01 and 12].
Nihon Hoshasen Gijutsu Gakkai Zasshi
; 69(3): 284-7, 2013 Mar.
Artigo
em Japonês
| MEDLINE | ID: mdl-23514857
7.
[Comparison of the absorbed dose at calibration depth of photon beams using the Japan Society of Medical Physics 12 beam quality conversion factor in the presence or absence of a waterproofing sleeve].
Nihon Hoshasen Gijutsu Gakkai Zasshi
; 69(10): 1161-4, 2013 Oct.
Artigo
em Japonês
| MEDLINE | ID: mdl-24140905
8.
Survey on reference dosimetry practice in Hokuriku region, Japan.
Radiat Prot Dosimetry
; 200(1): 106-112, 2023 Dec 29.
Artigo
em Inglês
| MEDLINE | ID: mdl-37950900
9.
[18F]FES PET Resolves the Diagnostic Dilemma of COVID-19-Vaccine-Associated Hypermetabolic Lymphadenopathy in ER-Positive Breast Cancer.
Diagnostics (Basel)
; 13(11)2023 May 25.
Artigo
em Inglês
| MEDLINE | ID: mdl-37296702
10.
Diagnostic and prognostic impact of serum-soluble UL16-binding protein 2 in lung cancer patients.
Cancer Sci
; 103(8): 1405-13, 2012 Aug.
Artigo
em Inglês
| MEDLINE | ID: mdl-22587355
11.
[The Lifetime Treasure Obtained from the JSRT Individual Research Mentorship Program for Two Years].
Nihon Hoshasen Gijutsu Gakkai Zasshi
; 73(12): 1303, 2017.
Artigo
em Japonês
| MEDLINE | ID: mdl-29269629
12.
Evaluation of entrance window deformation in water phantom with window thickness of 5 mm for horizontal beam measurements.
Radiol Phys Technol
; 14(4): 390-395, 2021 Dec.
Artigo
em Inglês
| MEDLINE | ID: mdl-34490553
13.
[A study of collimator scatter factors of rectangular irradiation fields using the virtual source plane].
Nihon Hoshasen Gijutsu Gakkai Zasshi
; 66(3): 225-30, 2010 Mar 20.
Artigo
em Japonês
| MEDLINE | ID: mdl-20379063
14.
Longitudinal assessment of U-shaped and inverted U-shaped developmental changes in the spontaneous movements of infants via markerless video analysis.
Sci Rep
; 10(1): 16827, 2020 10 08.
Artigo
em Inglês
| MEDLINE | ID: mdl-33033352
15.
Technical Note: Influence of entrance window deformation on reference dosimetry measurement in various beam modalities.
Med Phys
; 46(2): 1037-1043, 2019 Feb.
Artigo
em Inglês
| MEDLINE | ID: mdl-30500984
16.
Effect of Magnesium as Substitute Material in Enzyme-Mediated Calcite Precipitation for Soil-Improvement Technique.
Front Bioeng Biotechnol
; 4: 37, 2016.
Artigo
em Inglês
| MEDLINE | ID: mdl-27200343
17.
Retrobulbar amphotericin B injections for treatment of invasive sino-orbital aspergillosis.
Jpn J Ophthalmol
; 51(4): 309-11, 2007.
Artigo
em Inglês
| MEDLINE | ID: mdl-17660997
18.
Therapeutic antitumor efficacy of anti-epidermal growth factor receptor antibody, cetuximab, against malignant pleural mesothelioma.
Int J Oncol
; 41(5): 1610-8, 2012 Nov.
Artigo
em Inglês
| MEDLINE | ID: mdl-22922885
19.
Sequential change of ophthalmic findings after bypass graft surgery in Takayasu disease.
Retina
; 25(2): 225-7, 2005.
Artigo
em Inglês