2.
Phys Rev Lett ; 125(1): 011801, 2020 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-32678643

RESUMO

We present the first search for bosonic superweakly interacting massive particles (super-WIMPs) as keV-scale dark matter candidates performed with the GERDA experiment. GERDA is a neutrinoless double-ß decay experiment which operates high-purity germanium detectors enriched in ^{76}Ge in an ultralow background environment at the Laboratori Nazionali del Gran Sasso (LNGS) of INFN in Italy. Searches were performed for pseudoscalar and vector particles in the mass region from 60 keV/c^{2} to 1 MeV/c^{2}. No evidence for a dark matter signal was observed, and the most stringent constraints on the couplings of super-WIMPs with masses above 120 keV/c^{2} have been set. As an example, at a mass of 150 keV/c^{2} the most stringent direct limits on the dimensionless couplings of axionlike particles and dark photons to electrons of g_{ae}<3×10^{-12} and α^{'}/α<6.5×10^{-24} at 90% credible interval, respectively, were obtained.

3.
Phys Rev Lett ; 119(4): 041801, 2017 Jul 28.
Artigo em Inglês | MEDLINE | ID: mdl-29341770

RESUMO

We report the results of a first experimental search for lepton number violation by four units in the neutrinoless quadruple-ß decay of ^{150}Nd using a total exposure of 0.19 kg yr recorded with the NEMO-3 detector at the Modane Underground Laboratory. We find no evidence of this decay and set lower limits on the half-life in the range T_{1/2}>(1.1-3.2)×10^{21} yr at the 90% C.L., depending on the model used for the kinematic distributions of the emitted electrons.

4.
Phys Rev Lett ; 107(6): 062504, 2011 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-21902318

RESUMO

We report results from the NEMO-3 experiment based on an exposure of 1275 days with 661 g of (130)Te in the form of enriched and natural tellurium foils. The ßß decay rate of (130)Te is found to be greater than zero with a significance of 7.7 standard deviations and the half-life is measured to be T(½)(2ν) = [7.0 ± 0.9(stat) ± 1.1(syst)] × 10(20) yr. This represents the most precise measurement of this half-life yet published and the first real-time observation of this decay.

5.
Eur Phys J C Part Fields ; 81(6): 505, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34720720

RESUMO

Neutrinoless double- ß decay of 76 Ge is searched for with germanium detectors where source and detector of the decay are identical. For the success of future experiments it is important to increase the mass of the detectors. We report here on the characterization and testing of five prototype detectors manufactured in inverted coaxial (IC) geometry from material enriched to 88% in 76 Ge. IC detectors combine the large mass of the traditional semi-coaxial Ge detectors with the superior resolution and pulse shape discrimination power of point contact detectors which exhibited so far much lower mass. Their performance has been found to be satisfactory both when operated in vacuum cryostat and bare in liquid argon within the Gerda setup. The measured resolutions at the Q-value for double- ß decay of 76 Ge ( Q ß ß  = 2039 keV) are about 2.1 keV full width at half maximum in vacuum cryostat. After 18 months of operation within the ultra-low background environment of the GERmanium Detector Array (Gerda) experiment and an accumulated exposure of 8.5 kg · year, the background index after analysis cuts is measured to be 4 . 9 - 3.4 + 7.3 × 10 - 4 counts / ( keV · kg · year ) around Q ß ß . This work confirms the feasibility of IC detectors for the next-generation experiment Legend.

6.
Appl Radiat Isot ; 123: 54-59, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28242294

RESUMO

The BiPo-3 detector is a low radioactive detector dedicated to measuring ultra-low natural contaminations of 208Tl and 214Bi in thin materials, initially developed to measure the radiopurity of the double ß decay source foils of the SuperNEMO experiment at the µBq/kg level. The BiPo-3 technique consists in installing the foil of interest between two thin ultra-radiopure scintillators coupled to low radioactive photomultipliers. The design and performances of the detector are presented. In this paper, the final results of the 208Tl and 214Bi activity measurements of the first enriched 82Se foils are reported for the first time, showing the capability of the detector to reach sensitivities in the range of some µBq/kg.

7.
Phys Rev Lett ; 95(18): 182302, 2005 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-16383896

RESUMO

The NEMO 3 detector, which has been operating in the Fréjus underground laboratory since February 2003, is devoted to the search for neutrinoless double-beta decay (beta beta 0v). The half-lives of the two neutrino double-beta decay (beta beta 2v) have been measured for 100Mo and 82Se. After 389 effective days of data collection from February 2003 until September 2004 (phase I), no evidence for neutrinoless double-beta decay was found from approximately 7 kg of 100Mo and approximately 1 kg of 82Se. The corresponding limits are T1/2(beta beta0v) > 4.6 x 10(23) yr for 100Mo and T1/2(beta beta 0v) > 1.0 x 10(23) yr for 82Se (90% C.L.). Depending on the nuclear matrix element calculation, the limits for the effective Majorana neutrino mass are < 0.7-2.8 e/v for 100Mo and < 1.7-4.9 eV for 82Se.