Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Opt Express ; 25(2): 1019-1029, 2017 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-28157983

RESUMO

The performance of X-ray and neutron grating interferometers is characterised by their visibility, which is a measure for the maximum achievable contrast. In this study we show how the real grating geometry in a grating interferometer with three gratings impacts the interference and self projection that leads to visibility in the first place. We quantify the individual contributions of wavelength distributions and grating shapes in terms of visibility reduction by determining the absolute as well as relative effect of each contribution. The understanding of the impact of changed geometry and wavelength distributions on the interference of neutrons/X-rays allows us to present the first fully quantitative model of a grating interferometer setup. We demonstrate the capability of the simulation framework by building a model of the neutron grating interferometer at the ICON beamline and directly comparing simulated and measured visibility values. The general nature of the model makes it possible to extend it to any given grating interferometer for both X-rays and neutrons.

2.
Appl Radiat Isot ; 208: 111275, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38484591

RESUMO

Accurate measurements of photonuclear reaction cross sections are crucial for a number of applications, including radiation shielding design, absorbed dose calculations, reactor physics and engineering, nuclear safeguard and inspection, astrophysics, and nuclear medicine. Primarily motivated by the study of the production of selected radionuclides with high-energy photon beams (mainly 225Ac, 47Sc, and 67Cu), we have established a methodology for the measurement of photonuclear reaction cross sections with the microtron accelerator available at the Swiss Federal Institute of Metrology (METAS). The proposed methodology is based on the measurement of the produced activity with a High Purity Germanium (HPGe) spectrometer and on the knowledge of the photon fluence spectrum through Monte Carlo simulations. The data analysis is performed by applying a Bayesian fitting procedure to the experimental data and by assuming a functional trend of the cross section, in our case a Breit-Wigner function. We validated the entire methodology by measuring a well-established photonuclear cross section, namely the 197Au(γ, n)196Au reaction. The results are consistent with those reported in the literature.

3.
Z Med Phys ; 33(4): 601-617, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37202239

RESUMO

The SSRMP recommendations on reference dosimetry in kilovolt beams as used in radiation therapy were revised to establish current practice in Switzerland. The recommendations specify the dosimetry formalism, reference class dosimeter systems and conditions used for the calibration of low and medium energy x-ray beams. Practical guidance is provided on the determination of the beam quality specifier and all corrections required for converting instrument readings to absorbed dose to water. Guidance is also provided on the determination of relative dose under non-reference conditions and on the cross calibration of instruments. The effect of lack of electron equilibrium and influence of contaminant electrons when using thin window plane parallel chambers at x-ray tube potentials higher than 50kV is elaborated in an appendix. In Switzerland the calibration of the reference system used for dosimetry is regulated by law. METAS and IRA are the authorities providing this calibration service to the radiotherapy departments. The last appendix of these recommendations summarise this calibration chain.


Assuntos
Radiometria , Radioterapia de Alta Energia , Raios X , Planejamento da Radioterapia Assistida por Computador , Radiografia , Calibragem , Água
4.
Opt Express ; 19(14): 13604-11, 2011 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-21747516

RESUMO

X-ray differential phase contrast computed tomography (DPC CT) with a Talbot-Lau interferometer setup allows visualizing the three-dimensional distribution of the refractive index by measuring the shifts of an interference pattern due to phase variations of the X-ray beam. Unfortunately, severe reconstruction artifacts appear in the presence of differential phase wrapping and clipping. In this paper, we propose to use the attenuation contrast, which is obtained from the same measurement, for correcting the DPC signal. Using the example of a DPC CT measurement with pronounced phase artifacts, we will discuss the efficiency of our phase artifact correction method.


Assuntos
Algoritmos , Artefatos , Imageamento Tridimensional/instrumentação , Interferometria/instrumentação , Intensificação de Imagem Radiográfica/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento
5.
Phys Med Biol ; 65(6): 065005, 2020 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-32028275

RESUMO

In magnetic resonance guided radiotherapy (MRgRT) radiation dose measurements needs to be performed in the presence of a magnetic field. In this study, the influence of magnetic fields on the readings of a Fricke detector, a chemical dosimeter, have been investigated in 6 MV photon beams. This type of detector has been chosen, as the Federal Office of Metrology (METAS, Switzerland) has great experience with Fricke dosimetry and since it is not expected that this detector is greatly affected by the presence of a magnetic field. Magnetic fields with field strengths between 0 T and 1.42 T were applied during the detector irradiation. In a 5 × 10 cm2 irradiation field, the Fricke readings are affected less than 0.9% by the applied magnetic fields. Taking the altered dose distribution due to the magnetic field ([Formula: see text]) into account, the magnetic field correction factors ([Formula: see text]) for the Fricke detector at 0.35 T and 1.42 T are determined to be 0.9948 and 0.9980, respectively. These small corrections hardly exceed the measurement uncertainties. Hence, we could proof that the Fricke detector is not significantly influenced by the presence of a magnetic field. The Fricke detector was also tested for the feasibility of measuring output factors in the presence of magnetic fields. For irradiation field sizes larger than the detector (>2 × 2 cm2), comparable results were obtained as for other detectors. The output factors decrease when a magnetic field is applied. This effect is more pronounce for larger magnetic field strengths and smaller irradiation fields due to shifts of the depth dose curves and asymmetry of lateral dose profiles.


Assuntos
Campos Magnéticos , Fótons/uso terapêutico , Radiometria/métodos , Aceleradores de Partículas , Incerteza
6.
Phys Med ; 80: 134-150, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33181444

RESUMO

UHDpulse - Metrology for advanced radiotherapy using particle beams with ultra-high pulse dose rates is a recently started European Joint Research Project with the aim to develop and improve dosimetry standards for FLASH radiotherapy, very high energy electron (VHEE) radiotherapy and laser-driven medical accelerators. This paper gives a short overview about the current state of developments of radiotherapy with FLASH electrons and protons, very high energy electrons as well as laser-driven particles and the related challenges in dosimetry due to the ultra-high dose rate during the short radiation pulses. We summarize the objectives and plans of the UHDpulse project and present the 16 participating partners.


Assuntos
Elétrons , Radiometria , Lasers , Aceleradores de Partículas , Prótons , Radioterapia , Dosagem Radioterapêutica , Radioterapia de Alta Energia
7.
Appl Radiat Isot ; 145: 205-208, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30641434

RESUMO

43,44Sc/47Sc is one of the most promising theranostic pairs in nuclear medicine. The co-emission of 1157 keV γ-rays with 99.9% branching ratio by 44Sc and the presence of its metastable state 44 mSc push to favour the adoption of 43Sc for Positron Emission Tomography (PET) diagnostic procedures to lighten the dose to the patient and to the personnel. The ß+ emitter 43Sc can be produced at a medical cyclotron by proton bombardment of an enriched 43Ca or 46Ti oxide target. 43Sc can be also produced by deuteron bombardment of an enriched 42Ca oxide target. Only a few medical cyclotrons currently in operation offer deuteron beams. Some can be adapted to operate both a proton or a deuteron source. To compare these three production routes, an accurate knowledge of the cross-sections is essential. In this paper, we report on the cross-section measurement of the reaction 42Ca(d,n)43Sc performed at the 6 MV HVEC EN-Tandem of the Ion Beam Physics group at ETH in Zürich. A study of the production yield by using commercially available enriched target materials is also presented.


Assuntos
Marcação por Isótopo/métodos , Radioisótopos/isolamento & purificação , Escândio/isolamento & purificação , Radioisótopos de Cálcio/química , Ciclotrons , Deutério , Humanos , Tomografia por Emissão de Pósitrons , Prótons , Compostos Radiofarmacêuticos/isolamento & purificação , Nanomedicina Teranóstica
8.
Appl Radiat Isot ; 134: 95-99, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29054450

RESUMO

A portable instrument was developed at the Institute of Radiation Physics (IRA) for on-site radionuclides measurements. It will enable the measurement of short-lived radionuclides in nuclear medicine departments or isotope production centres. The system involves an ionization chamber read directly by an electrometer and it was optimized to ensure a good reproducibility through the selection of an appropriate vial, filling volume and source position in the well chamber, as well as monitoring the external background and performing a detailed uncertainty estimation. The calibration factors were determined using solutions whose activity concentration is traceable to the international reference system using the IRA reference chamber. Currently the transfer ionization chamber is calibrated for F-18, C-11, O-15, N-13, I-131 and Tc-99m. The final instrument is able to measure isotope activities with a relative standard uncertainty not larger than 1%.

9.
Rev Sci Instrum ; 78(9): 093707, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17902955

RESUMO

A refractive x-ray lens was characterized using a magnifying cone beam setup for differential phase contrast imaging in combination with a microfocus x-ray tube. Thereby, the differential and the total phase shift of x rays transmitted through the lens were determined. Lens aberrations have been characterized based on these refractive properties.

10.
Phys Med Biol ; 60(2): 925-8, 2015 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-25564879

RESUMO

In a recent paper (Scholkamm et al 2014 Phys. Med. Biol. 59 1425-40) we presented a new image denoising, fusion and enhancement framework for combining and optimal visualization of x-ray attenuation contrast, differential phase contrast and dark-field contrast images retrieved from x-ray Talbot-Lau grating interferometry. In this comment we give additional information and report about the application of our framework to breast cancer tissue which we presented in our paper as an example. The applied procedure is suitable for a qualitative comparison of different algorithms. For a quantitative juxtaposition original data would however be needed as an input.


Assuntos
Aumento da Imagem/métodos , Razão Sinal-Ruído , Humanos
11.
Phys Med Biol ; 59(6): 1425-40, 2014 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-24584079

RESUMO

This paper introduces a new image denoising, fusion and enhancement framework for combining and optimal visualization of x-ray attenuation contrast (AC), differential phase contrast (DPC) and dark-field contrast (DFC) images retrieved from x-ray Talbot-Lau grating interferometry. The new image fusion framework comprises three steps: (i) denoising each input image (AC, DPC and DFC) through adaptive Wiener filtering, (ii) performing a two-step image fusion process based on the shift-invariant wavelet transform, i.e. first fusing the AC with the DPC image and then fusing the resulting image with the DFC image, and finally (iii) enhancing the fused image to obtain a final image using adaptive histogram equalization, adaptive sharpening and contrast optimization. Application examples are presented for two biological objects (a human tooth and a cherry) and the proposed method is compared to two recently published AC/DPC/DFC image processing techniques. In conclusion, the new framework for the processing of AC, DPC and DFC allows the most relevant features of all three images to be combined in one image while reducing the noise and enhancing adaptively the relevant image features. The newly developed framework may be used in technical and medical applications.


Assuntos
Aumento da Imagem/métodos , Razão Sinal-Ruído , Algoritmos , Humanos , Interferometria , Prunus , Dente , Raios X
12.
Rev Sci Instrum ; 81(7): 073709, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20687733

RESUMO

The sensitivity of x-ray radiographic images, meaning the minimal detectable change in the thickness or in the index of refraction of a sample, is directly related to the uncertainty of the measurement method. In the following work, we report on the recent development of quantitative descriptions for the stochastic error of grating-based differential phase contrast imaging (DPCi). Our model includes the noise transfer characteristics of the x-ray detector and the jitter of the phase steps. We find that the noise in DPCi depends strongly on the phase stepping visibility and the sample properties. The results are supported by experimental evidence acquired with our new instrument with a field of view of 50x70 mm(2). Our conclusions provide general guidelines to optimize grating interferometers for specific applications and problems.


Assuntos
Radiografia/métodos , Interferometria , Radiografia/instrumentação , Processos Estocásticos , Incerteza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA