Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Brain Inj ; 29(5): 658-60, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25625410

RESUMO

BACKGROUND: Neuroleptic malignant syndrome (NMS) is a rare life-threatening disorder resulting from treatment with neuroleptic agents and other drugs that act as dopamine antagonists. NMS most often occurs shortly after the initiation, dose increase or withdrawal of the offending agent, but can rarely occur after long-term treatment at stable doses. Immediate discontinuation of the causative agent (or re-administration if the cause is the withdrawal of neuroleptic therapy) along with supportive therapy to maintain cardiorespiratory stability and to reduce fever are the cornerstone of the management of NMS. Additional 'specific' treatments include dantrolene, bromocriptine and amantadine, but their role in the management of NMS is controversial. CASE STUDY: This study reports the case of NMS associated with long-term treatment with olanzapine at a stable dose. Administration of dantrolene was well-tolerated and resulted in prompt resolution of NMS symptoms.


Assuntos
Benzodiazepinas/administração & dosagem , Benzodiazepinas/efeitos adversos , Dantroleno/uso terapêutico , Síndrome Maligna Neuroléptica/tratamento farmacológico , Síndrome Maligna Neuroléptica/etiologia , Idoso de 80 Anos ou mais , Feminino , Humanos , Olanzapina
2.
Cureus ; 16(6): e61493, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38952598

RESUMO

Degeneration of the surgical bioprosthetic valves remains one of the most common complications of surgical valve replacement. Redo surgery is the gold standard, but unfortunately, most of these patients are deemed inoperable because of the high perioperative mortality. Transcatheter implantation of a new valve inside the degenerated bioprosthesis (valve-in-valve (ViV)) has emerged as an alternative solution. A 79-year-old patient with a medical history of surgical replacement of the mitral valve with a bioprosthetic valve, coronary artery bypass graft surgery (CABG) with implantation of the left internal mammary artery (LIMA) to the left anterior descending artery (LAD), paroxysmal atrial fibrillation, and chronic kidney disease was referred to our hospital for ViV transcatheter mitral valve replacement (TMVR). He had recent hospitalizations with pulmonary edema caused by severe stenosis of the bioprosthetic valve and his perioperative mortality for a redo surgery was very high (EuroSCORE II: 13.72%). The ViV TMVR was performed with a transseptal approach and after the implantation of the new valve, the mean pressure gradient was dropped from 19.39 to 2.33 mmHg. The procedure was technically successful and the patient was discharged asymptomatic.

3.
Cureus ; 16(4): e59090, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38800257

RESUMO

A 58-year-old male with a medical history of arterial hypertension, dyslipidemia, and psoriasis was admitted for a scheduled surgical removal of the thyroid gland. During the surgery, the patient suffered severe blood loss caused by vascular complications. After the operation, his electrocardiogram showed diffuse ST segment elevation along with high-sensitivity cardiac troponin T elevation and severe left ventricular systolic dysfunction. An emergency coronary angiography showed unobstructed coronary arteries. However, the left ventriculography demonstrated akinesia of the apical segments and hyperkinesia of the basal segments during systole. The patient was diagnosed with Takotsubo syndrome and he was successfully stabilized over the course of the next few days. Takotsubo cardiomyopathy is characterized by transient left ventricular systolic dysfunction and although the clinical and electrocardiographical presentation is similar to an acute coronary syndrome, the coronary arteries are unobstructed. Stressful events, both physical or psychological, could trigger an excessive catecholaminergic response which can cause the syndrome. Repetitive echocardiograms in our patient demonstrated complete recovery of the systolic function after a few days.

5.
J Clin Med ; 13(11)2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38892987

RESUMO

Background/Objectives: Radial artery occlusion (RAO) is the most common complication of transradial coronary catheterization. In this study, we aimed to evaluate the incidence of RAO and identify the risk factors that predispose patients to it. Methods: We conducted an investigator-initiated, prospective, multicenter, open-label study involving 1357 patients who underwent cardiac catheterization via the transradial route for angiography and/or a percutaneous coronary intervention (PCI). Univariate and multivariate logistic regression analyses were performed to identify potential predictors of RAO occurrence. Additionally, a subgroup analysis only for patients undergoing PCIs was performed. Results: The incidence of RAO was 9.5% overall, 10.6% in the angiography-only group and 6.2% in the PCI group. Independent predictors of RAO were as follows: (i) the female gender (aOR = 1.72 (1.05-2.83)), (ii) access site cross-over (aOR = 4.33 (1.02-18.39)), (iii) increased total time of the sheath in the artery (aOR = 1.01 (1.00-1.02)), (iv) radial artery spasms (aOR = 2.47 (1.40-4.36)), (v) the presence of a hematoma (aOR = 2.28 (1.28-4.06)), (vi) post-catheterization dabigatran use (aOR = 5.15 (1.29-20.55)), (vii) manual hemostasis (aOR = 1.94 (1.01-3.72)) and (viii) numbness at radial artery ultrasound (aOR = 8.25 (1.70-40)). Contrariwise, two variables were independently associated with increased odds for radial artery patency (RAP): (i) PCI performance (aOR = 0.19 (0.06-0.63)), and (ii) a higher dosage of intravenous heparin per patient weight (aOR = 0.98 (0.96-0.99)), particularly, a dosage of >50 IU/kg (aOR = 0.56 (0.31-1.00)). In the PCI subgroup, independent predictors of RAO were as follows: (i) radial artery spasms (aOR = 4.48 (1.42-14.16)), (ii) the use of intra-arterial nitroglycerin as a vasodilator (aOR = 7.40 (1.67-32.79)) and (iii) the presence of symptoms at echo (aOR = 3.80 (1.46-9.87)), either pain (aOR = 2.93 (1.05-8.15)) or numbness (aOR = 4.66 (1.17-18.57)). On the other hand, the use of intra-arterial verapamil as a vasodilator (aOR = 0.17 (0.04-0.76)) was independently associated with a greater frequency of RAP. Conclusions: The incidence of RAO in an unselected, all-comers European population after transradial coronary catheterization for angiography and/or PCIs is similar to that reported in the international literature. Several RAO prognostic factors have been confirmed, and new ones are described. The female gender, radial artery trauma and manual hemostasis are the strongest predictors of RAO. Our results could help in the future identification of patients at higher risk of RAO, for whom less invasive diagnostic procedures maybe preferred, if possible.

6.
J Invasive Cardiol ; 35(2): E101-E102, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36735871

RESUMO

In this difficult case of an 80-year-old woman with an acute coronary syndrome and extremely calcified and tortuous left anterior descending artery, the operators were unable to insert the stent into the distal cylinder of the Telescope after encountering strong resistance. Assuming the stent was stuck at the level of the distal cylinder entry pot, they decided to remove both the guide catheter extension (GCE) and the stent as a single unit to prevent complications. Since the first GCE was introduced in 2009, many other GCE systems have been developed and there is accumulating experience with their use. To our knowledge, this is the first description of stent damage occurring during the insertion in the distal cylinder of the Telescope GCE (Medtronic). Interventional cardiologists should always be prepared to face unexpected complications related to sophisticated devices such as GCE.


Assuntos
Intervenção Coronária Percutânea , Feminino , Humanos , Idoso de 80 Anos ou mais , Angiografia Coronária , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Catéteres , Stents/efeitos adversos
7.
Life (Basel) ; 13(8)2023 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-37629642

RESUMO

INTRODUCTION: The self-expanding, resheathable, repositionable transcatheter aortic heart valve Portico is being used successfully for transcatheter aortic valve implantation procedures (TAVI) in patients with severe aortic stenosis. The aim of this study was to evaluate outcomes at 2 years after TAVI with the Portico valve. METHODS: Multicenter registry of clinical, echocardiographic and survival data from consecutive patients treated with the Portico TAVI system (Abbott, Chicago, IL, USA) in three cath labs in Northern Greece and Epirus during 2017-2020. The primary end point was all-cause mortality at 24 months. Secondary end points included procedural outcomes (efficacy and safety) and echocardiographic measurements. RESULTS: A total of 90 patients (81 ± 6 years, 50% females, mean age 81 ± 6 years) were included in the registry. The indication for implantation was severe, symptomatic aortic stenosis (NYHA III, IV) in eighty-two (91.1%) and degeneration of a prosthetic aortic valve in eight (8.9%) patients. All patients were categorized as high surgical risk (mean Logistic Euroscore 25.9 ± 10, Euroscore II 7.7 ± 4.4 and STS score 10.8 ± 8.9). The procedure was performed transfemorally in all patients, under general anesthesia in 95.6%, under TOE guidance in 21.1%, with native valve predilatation in 46.7%, and the "resheath" option was used in 31.1% of the cases. The implantation was successful in 97.8% and there was a need for a second valve in 2.2% of the cases. Complications included permanent pacemaker implantation (16.7%), access cite complications (15.6%), arrythmias (23.3%), paravalvular leak (moderate 7.8%, severe 1.1%), acute kidney injury (7.8%), no strokes and one death during the procedure. Aortic valve peak velocity, peak and mean pressure gradients, were significantly reduced after the procedure. All-cause mortality at 1, 12 and 24 months was 4.4%, 6.7% and 7.8%, respectively. CONCLUSIONS: TAVI with the Portico system comprises an effective and safe solution for the management of severe, symptomatic aortic stenosis in high-risk surgical patients.

8.
Life (Basel) ; 13(11)2023 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-38004365

RESUMO

Advances in the diagnosis and treatment of pulmonary hypertension (PH) have gradually improved the disease course. This retrospective cohort study aims to explore the diagnostic hemodynamic profile and survival of PH patients and their temporal changes, as well as investigate potential prognostic factors. Overall, 257 adult patients were diagnosed with PH following right heart catheterization (RHC) from January 2008 to June 2023 according to the hemodynamic cut-off values proposed by the corresponding ESC/ERS guidelines at the time RHC was performed. Of these patients, 46.3% were Group 1, 17.8% Group 2, 14.0% Group 3, 18.0% Group 4, and 3.0% Group 5 PH. Temporal improvement in both diagnostic hemodynamic profile and survival of patients with PH and pulmonary arterial hypertension (PAH) was identified after 2013. Survival analysis demonstrated 5-year survival rates of 65% in Group 1 PH (90.3% in idiopathic PAH) and 77% in Group 4 PH. PAH patients being at low risk at diagnosis presented a similar 1-year all-cause mortality rate (12.4%) with high-risk ones (12.8%), primarily due to non-PH-related causes of death (62%), while high-risk patients died mostly due to PH (67%). The observed improvements in diagnostic hemodynamic profiles and overall survival highlight the importance of timely diagnosis and successful treatment strategies in PH.

9.
Future Cardiol ; 18(2): 91-100, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34397270

RESUMO

Radial artery occlusion (RAO) is the commonest complication of transradial catheterization. There is no evidence-based therapy, in the frame of a randomized control study, for the treatment of RAO. The purpose of the LOW-RAO study is to question the hypothesis if low-molecular-weight heparin is effective in the treatment of RAO after transradial coronary catheterization (both angiography and percutaneous coronary intervention). It is a prospective, open label, randomized controlled trial that will randomize 60 patients with RAO, irrespective of symptoms, into two groups, one receiving anticoagulation with low-molecular-weight heparin and the other receiving no treatment. The primary end point is improvement in radial artery patency rate at 4 weeks after the procedure. Clinical trial registration number: NCT04196309 (ClinicalTrials.gov).


Lay abstract Coronary angiogram, a procedure to check if there is any blockage in the heart's blood vessels, is often performed nowadays through a vessel in the wrist, called radial artery. One of the commonest risks of this procedure is the blockage of the radial artery afterward. This could go totally unnoticed; however, it may cause pain, tingling and numbness feeling in the fingers, loss of handgrip power and inability to use the artery for medical reasons in the future. Since there is no definite treatment for this situation up to now, the purpose of the LOW-RAO study is to try to find a solution for this problem. Patients diagnosed with radial artery blockage, will randomly receive for up to 4 weeks an injection that contains a blood-thinner, called low-molecular-weight heparin and is believed to be able to reopen the blocked radial artery. All patients will be regularly followed-up with ultrasounds for a month to check any progress with the blockage.


Assuntos
Arteriopatias Oclusivas , Artéria Radial , Cateterismo Cardíaco , Angiografia Coronária , Heparina , Heparina de Baixo Peso Molecular/uso terapêutico , Humanos , Estudos Prospectivos
10.
Cardiovasc Revasc Med ; 28S: 222-224, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33514488

RESUMO

A 72-year-old male patient, with first degree atrioventricular block and LBBB on his baseline ECG, developed persistent complete atrioventricular block after recanalization of a chronic total occlusion of his left anterior descending artery (LAD) and ultimately underwent permanent pacemaker implantation. Occlusion of the second septal branch, probably supplying the right branch of the His bundle is speculated to have led to this complication. During elective intervention to the LAD territory in patients with prior conduction abnormalities on the ECG, care should be taken to preserve normal blood flow to the septal perforators. When a deterioration in septal perfusion occurs restoration of flow by wiring and balloon dilatation should be considered.


Assuntos
Bloqueio Atrioventricular , Marca-Passo Artificial , Intervenção Coronária Percutânea , Doenças Vasculares , Idoso , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Masculino , Marca-Passo Artificial/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos
11.
Cardiol Rev ; 29(4): 210-216, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34061817

RESUMO

Distal transradial access, through puncture of the radial artery at its course in the anatomical snuffbox, has emerged recently as an alternative approach for coronary catheterization. Several advantages of this approach seem promising and several studies are trying to elucidate its features. This review provides an overview of the snuffbox approach for coronary catheterization and summarizes the key results of the research conducted so far.


Assuntos
Cateterismo Cardíaco , Artéria Radial , Angiografia Coronária , Humanos , Punções
12.
Ther Adv Neurol Disord ; 14: 17562864211029540, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34285718

RESUMO

BACKGROUND: An alarming cerebro/cardiovascular collateral damage, reflected by a decline in admissions for acute stroke (AS) and acute coronary syndrome (ACS), was observed during the initial phase of the COVID-19 pandemic, thereby leading to a re-design of public campaigns. However, there are limited data regarding the AS and ACS hospitalization rates during the second wave of the pandemic, which was followed by re-imposition of lockdowns. METHODS: We calculated the rate of AS and ACS hospitalizations from three representative tertiary care hospitals in Greece during a 2-month period (November-December 2020) of the second wave of the COVID-19 pandemic compared with the corresponding control period in 2019 from three representative tertiary care hospitals in Greece. This was a follow-up study with identical design to our previous report evaluating AS and ACS hospitalizations during the first wave of the pandemic (March-April 2020). RESULTS: Compared with 2019, there was a 34% relative reduction of AS hospitalizations [incidence rate ratio (IRR): 0.66, 95% confidence interval (CI): 0.48-0.92, p = 0.013] and 33% relative reduction of ACS hospitalizations (IRR: 0.67, 95% CI: 0.54-0.83, p < 0.001) during the second wave of the COVID-19 pandemic. The relative reduction was smaller and did not reach the level of statistical significance for the respective syndromes (haemorrhagic stroke: IRR 0.87, 95% CI: 0.41-1.82, p = 0.71; ST-elevation myocardial infarction: IRR 0.81, 95% CI: 0.57-1.14, p = 0.22). CONCLUSION: AS and ACS hospitalizations were persistently reduced during the second wave of the COVID-19 pandemic compared with 2019 in Greece. This decline was similar to the observations during the first wave despite the large differences in the epidemiological COVID-19 burden. Lockdowns, a common characteristic in both waves, appear to have a detrimental indirect impact on cerebro/cardiovascular diseases in the general population.

13.
Hellenic J Cardiol ; 61(2): 106-109, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-30389385

RESUMO

BACKGROUND: Distal transradial access (dTRA) by the snuffbox approach for coronary catheterization has emerged as an alternative to the classic forearm TRA with certain advantages and limitations.The aim of this study was to evaluate the effectiveness and safety of the dTRA exclusively from the right arm. METHODS: Forty-nine consecutive patients (31 males and 18 females, mean age 64 ± 12 years), who were candidates for coronary catheterization in two cath laboratory centers, regardless of the indication, were recruited. Right dTRA was exclusively used. Radial artery patency both at the forearm and at the snuffbox region was evaluated 24 h after successful hemostasis by triplex ultrasonography. All complications were recorded until 24 h after the procedure. RESULTS: The indication for catheterization was an acute coronary syndrome in 24.5%, stable coronary artery disease in 22.4%, and other reasons in 53.1%. The overall failure attempt incidence was 10.2% and the mean puncture time 3.9 ± 4.1 min. Angiography only was performed in 81.8% and angiography followed by percutaneous coronary intervention in 18.2% of the patients. Manual hemostasis was applied in 63.6% of the patients, which had a significantly shorter duration than device hemostasis (11 ± 7 versus 198 ± 42 min, p < 0.001). No distal or forearm radial artery occlusion was observed on triplex ultrasonography 24 h after successful hemostasis. No major complications were recorded. CONCLUSIONS: This two-center study, utilizing exclusively the right dTRA, provides further data regarding the snuffbox approach in an all-comers population. Further worldwide reports will elucidate new aspects of the technique.


Assuntos
Cateterismo Periférico , Intervenção Coronária Percutânea , Artéria Radial , Idoso , Braço , Cateterismo Cardíaco , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
19.
JACC Cardiovasc Interv ; 11(11): 1050-1058, 2018 06 11.
Artigo em Inglês | MEDLINE | ID: mdl-29880098

RESUMO

OBJECTIVES: The aim of this study was to compare manual versus mechanical compression of the radial artery after coronary angiography via transradial access regarding radial artery occlusion (RAO), access-site bleeding complications, and duration of hemostasis. BACKGROUND: Hemostasis of the radial artery after sheath removal can be achieved either by manual compression at the puncture site or by using a mechanical hemostasis device. Because mechanical compression exerts a more stable, continuous pressure on the artery, it could be hypothesized that it is more effective compared with manual compression regarding hemostasis time, bleeding, and RAO risks. METHODS: A total of 589 patients undergoing diagnostic coronary angiography by transradial access with a 5-F sheath were randomized in a 1:1 ratio to receive either manual or mechanical patent hemostasis of the radial artery. Radial artery patency was evaluated by color duplex ultrasonography 24 h after the procedure. The primary endpoint was early RAO at 24 h. Secondary endpoints included access-site bleeding complications and duration of hemostasis. RESULTS: Thirty-six (12%) early RAOs occurred in the manual group, and 24 (8%) occurred in the mechanical group (p = 0.176). There were no significant differences between the 2 groups regarding access-site bleeding complications (hematoma, 52 [17%] vs. 50 [18%]; p = 0.749; bleedings, 8 [3%] vs. 9 [3%]; p = 1.000). Duration of hemostasis was significantly shorter in the manual group (22 ± 34 min vs. 119 ± 72 min with mechanical compression; p < 0.001). CONCLUSIONS: Manual and mechanical compression resulted in similar rates of early RAO, although the total duration of hemostasis was significantly shorter in the manual group.


Assuntos
Cateterismo Periférico/efeitos adversos , Angiografia Coronária , Hemorragia/prevenção & controle , Técnicas Hemostáticas , Artéria Radial , Idoso , Feminino , Grécia , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Pressão , Estudos Prospectivos , Punções , Artéria Radial/diagnóstico por imagem , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA