Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Arch Orthop Trauma Surg ; 143(10): 6261-6272, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37269350

RESUMO

INTRODUCTION: Posttraumatic MRI of ACL tears show a high prevalence of bone bruise (BB) without macroscopic proof of chondral damage. Controversial results are described concerning the association between BB and outcome after ACL tear. Aim of this study is to evaluate the influence of distribution, severity and volume of BB in isolated ACL injuries on function, quality of life and muscle strength following ACL reconstruction (ACLR). MATERIALS AND METHODS: MRI of n = 122 patients treated by ACLR without concomitant pathologies were evaluated. BB was differentiated by four localizations: medial/lateral femoral condyle (MFC/LFC) and medial/lateral tibial plateau (MTP/LTP). Severity was graded according to Costa-Paz. BB volumes of n = 46 patients were quantified (software-assisted volumetry). Outcome was measured by Lysholm Score (LS), Tegner Activity Scale (TAS), IKDC, isokinetics and SF-36. Measurements were conducted preoperatively (t0), 6 weeks (t1), 26 weeks (t2) and 52 weeks (t3) after ACLR. RESULTS: The prevalence of BB was 91.8%. LTP was present in 91.8%, LFC 64.8%, MTP 49.2% and MFC 28.7%. 18.9% were classified Costa-Paz I, 58.2% II and 14.8% III. Total BB volume was 21.84 ± 15.27 cm3, the highest value for LTP (14.31 ± 9.93 cm3). LS/TAS/IKDC/SF-36/isokinetics improved significantly between t0-t3 (p < 0.001). Distribution, severity and volume had no influence on LS/TAS/IKDC/SF-36/isokinetics (n.s.). CONCLUSIONS: No impact of BB after ACLR on function, quality of life and objective muscle strength was shown, unaffected by concomitant pathologies. Previous data regarding prevalence and distribution is confirmed. These results help surgeons counselling patients regarding the interpretation of extensive BB findings. Long-time follow-up studies are mandatory to evaluate an impact of BB on knee function due to secondary arthritis.


Assuntos
Lesões do Ligamento Cruzado Anterior , Cartilagem Articular , Contusões , Humanos , Lesões do Ligamento Cruzado Anterior/complicações , Lesões do Ligamento Cruzado Anterior/cirurgia , Qualidade de Vida , Ligamento Cruzado Anterior/cirurgia , Cartilagem Articular/cirurgia , Hematoma/complicações , Hemartrose , Contusões/complicações , Contusões/patologia
2.
Med J Aust ; 215(11): 531-535, 2021 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-34897722

RESUMO

OBJECTIVE: To test the urban myth that surplus chocolate Easter Bunnies are re-packaged as Santa Clauses for the following Christmas holiday season. DESIGN: Prospective radiographic cohort study of seasonal chocolate figurines, supplemented by anonymous 5-item questionnaire survey of belief in the re-wrapping myth (Generic Risk Items Noted by Chocolate consumers in Health care settings; GRINCH). SETTING: Two tertiary referral trauma centres in Germany (Berlin and Duisburg). PARTICIPANTS: Eighteen chocolate Easter Bunnies and 15 chocolate Santa Clauses from different manufacturers purchased during 2020; 502 randomly selected people passing through the entrance halls of the two hospitals during 16 September - 12 October 2020. MAIN OUTCOME MEASURES: Whole body computed tomography (WBCT) images of chocolate Easter Bunnies and Santa Clauses assessed by four independent, board-certified radiologists using a visual contour resemblance scale (CRS); survey participants' views on statements related to the re-wrapping myth. RESULTS: Expert examiners clearly distinguished the WBCT images of chocolate Easter Bunnies and Santa Clauses; the mean difference in CRS was 84.2 points (95% CI, 78.5-90.0 points), with excellent inter-observer agreement (mean intra-class correlation coefficient, 0.99; 95% CI, 0.99-1.00). A total of 214 survey participants (43%) disagreed and 145 (29%) agreed with the proposition that seasonal chocolate figurines are re-packaged and re-sold the following season. CONCLUSION: Although about one-third of our survey respondents did not rule out the possibility of seasonal sweets being re-used, WBCT imaging found no similarity between chocolate foil-wrapped Easter and Christmas figurines, providing solid evidence against this urban myth. Chocolate Santa Clauses are unlikely to pose a significant threat to hospital food hygiene requirements. TRIAL REGISTRATION: Current Controlled Trials, ISRCTN16847363 (prospective).


Assuntos
Férias e Feriados , Humanos , Estações do Ano , Senso de Humor e Humor como Assunto
3.
Eur Radiol ; 29(7): 3705-3713, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30783785

RESUMO

OBJECTIVES: To evaluate machine learning (ML) to detect chest CT examinations with dose optimization potential for quality assurance in a retrospective, cross-sectional study. METHODS: Three thousand one hundred ninety-nine CT chest examinations were used for training and testing of the feed-forward, single hidden layer neural network (January 2016-December 2017, 60% male, 62 ± 15 years, 80/20 split). The model was optimized and trained to predict the volumetric computed tomography dose index (CTDIvol) based on scan patient metrics (scanner, study description, protocol, patient age, sex, and water-equivalent diameter (DW)). The root mean-squared error (RMSE) was calculated as performance measurement. One hundred separate, consecutive chest CTs were used for validation (January 2018, 60% male, 63 ± 16 years), independently reviewed by two blinded radiologists with regard to dose optimization, and used to define an optimal cutoff for the model. RESULTS: RMSE was 1.71, 1.45, and 1.52 for the training, test, and validation dataset, respectively. The scanner and DW were the most important features. The radiologists found dose optimization potential in 7/100 of the validation cases. A percentage deviation of 18.3% between predicted and actual CTDIvol was found to be the optimal cutoff: 8/100 cases were flagged as suboptimal by the model (range 18.3-53.2%). All of the cases found by the radiologists were identified. One examination was flagged only by the model. CONCLUSIONS: ML can comprehensively detect CT examinations with dose optimization potential. It may be a helpful tool to simplify CT quality assurance. CT scanner and DW were most important. Final human review remains necessary. A threshold of 18.3% between the predicted and actual CTDIvol seems adequate for CT quality assurance. KEY POINTS: • Machine learning can be integrated into CT quality assurance to improve retrospective analysis of CT dose data. • Machine learning may help to comprehensively detect dose optimization potential in chest CT, but an individual review of the results by an experienced radiologist or radiation physicist is required to exclude false-positive findings.


Assuntos
Aprendizado de Máquina , Tomografia Computadorizada Multidetectores/normas , Garantia da Qualidade dos Cuidados de Saúde , Lesões por Radiação/prevenção & controle , Radiografia Torácica/normas , Doenças Torácicas/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Estudos Retrospectivos , Adulto Jovem
4.
Heart Surg Forum ; 22(3): E241-E246, 2019 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-31237551

RESUMO

BACKGROUND: In aortic root replacement, "preexisting" or "induced" aortic leaflet prolapse is related to advanced aortic root pathology and can indicate valve repair. Efforts should be made to perform root replacement before leaflet prolapse is in its maximum extent. MATERIALS AND METHODS: Thirty-nine patients with chronic aortic root dilatation and aortic valve regurgitation (AR) underwent a reimplantation procedure. Contrary to 32 of the 39 patients (group A), 7 of the 39 patients (group B) underwent cusp plication for prolapse. For both groups, data related to the diameter at the level of maximal tubular extension, sinotubular junction, sinus of Valsalva, aorto-ventricular junction (AVJ), and aortic annulus were obtained from preoperative computed tomography scans and analyzed comparatively. RESULTS: Group B showed a higher mean AR grade (P = .007), a higher mean diameter at the level of the aortic annulus (P = .038), AVJ (P = .037), and aortic sinus (P <.001) and a higher sinus dilatation index (existing-to-predicted diameter ratio) (P <.001) than group A. The sinus of Valsalva displayed the best predictive value regarding a plicature-indicating prolapse (P <.001; 95% confidence interval [CI]: 0.809-1.013). A diameter >40 mm was accompanied by an odds ratio (OR) of 24.6 (95% CI: 1.29-496.02). During the follow-up period of 29.0 ± 18.4 months (range: 6-62 months), 1 patient (group A) required reoperation 5 years postoperatively for progressive AR. CONCLUSION: The sinus of Valsalva diameter seems to have the greatest prognostic value for the development of prolapse. Our data suggest that root repair should be considered earlier in time before leaflet prolapse is complete, which most likely occurs when root dilatation becomes an aneurysm.


Assuntos
Insuficiência da Valva Aórtica/patologia , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Seleção de Pacientes , Idoso , Estudos de Coortes , Dilatação Patológica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prolapso , Reoperação , Fatores de Risco , Resultado do Tratamento
5.
Eur Radiol ; 28(8): 3221-3227, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29480342

RESUMO

PURPOSE: To analyse technical success, complications, and short- and intermediate-term outcomes after heparin-bonded stent graft implantation for the treatment of major abdominal vessel injury after upper abdominal surgery. METHODS: This retrospective, IRB-approved analysis included 29 consecutive patients (female: n = 6, male: n = 23, mean age 65.9 ± 11.2 years). All patients underwent angiography and attempted heparin-bonded stent-graft implantation because of a major visceral arterial injury after upper abdominal surgery. Electronic clinical records, angiographic reports and imaging datasets were reviewed to assess technical success and complications. Telephone interviews were performed to obtain follow-up information and to estimate short- (> 30 days) and intermediate-term (> 90 days) outcomes. RESULTS: Successful stent graft placement was achieved in 82.8% (24/29). Peri-interventional complications were observed in 20.7% (6/29) and delayed, angiography-associated complications were observed in 34.5% (10/29) of the patients. Symptomatic re-bleeding occurred in 24.1% (7/29). Short-term survival (> 30 days) was 72.4% (21/29). Intermediate survival (> 90 days) was 37.9% (11/29). CONCLUSION: Treatment of major vascular injuries with heparin-bonded stent grafts is feasible with a high technical success rate. However, survival depends on the underlying surgical condition, making interdisciplinary patient management mandatory. KEY POINTS: • Stent graft implantation is challenging, but has a high technical success rate. • Complications are frequent but surgical conversion is rarely necessary. • Survival depends on the underlying surgical condition causing the vascular injury. • Interdisciplinary management is crucial for the survival of these patients.


Assuntos
Anticoagulantes/uso terapêutico , Artérias/lesões , Implante de Prótese Vascular/métodos , Prótese Vascular , Heparina/uso terapêutico , Stents , Lesões do Sistema Vascular/cirurgia , Idoso , Idoso de 80 Anos ou mais , Angiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Retrospectivos , Análise de Sobrevida
6.
J Radiol Prot ; 38(2): 536-548, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29261100

RESUMO

Size-specific institutional diagnostic reference levels (DRLs) were generated for chest and abdominopelvic computed tomography (CT) based on size-specific dose estimates (SSDEs) and depending on patients' water-equivalent diameter (Dw). 1690 CT examinations were included in the IRB-approved retrospective study. SSDEs based on the mean water-equivalent diameter of the entire scan volume were calculated automatically. SSDEs were analyzed for different patient sizes and institutional DRLs (iDRLS; 75% percentiles) based on Dw and SSDEs were generated. iDRLs were compared to the national DRLs. Mean volumetric computed tomography dose index (CTDIvol), Dw and SSDEs for all 1690 CT examinations were 7.2 ± 4.0 mGy (0.84-47.9 mGy), 29.0 ± 3.4 cm and 8.5 ± 3.8 mGy (1.2-37.7 mGy), respectively. Overall, the mean SSDEs of all CT examinations were higher than the CTDIvol in chest CT, abdominopelvic CT and upper abdominal CT, respectively (p < 0.001 for all). There was a strong linear correlation between Dw and SSDEs in chest (R2 = 0.66), abdominopelvic (R2 = 0.98) and upper abdominal CT (R2 = 0.96) allowing for the implementation of size-specific institutional DRLs based on SSDEs and patients' Dw. We generated size-specific, Dw-dependent institutional DRLs based on SSDEs, which allow for easier and more comprehensive analyses of CT radiation exposure. Our results indicate that implementation of SSDEs into national DRLs may be beneficial.


Assuntos
Doses de Radiação , Tomografia Computadorizada por Raios X/normas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estatura , Índice de Massa Corporal , Peso Corporal , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Água , Adulto Jovem
7.
Europace ; 19(12): 2036-2041, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28007749

RESUMO

AIMS: The subcutaneous cardioverter defibrillator was designed to overcome electrode complications of transvenous defibrillation systems. While largely achieved, pocket complications have increased. Subcutaneous implantation of the pulse generator leaves it prone to erosion, extrusion, discomfort, and poor cosmesis. METHODS AND RESULTS: We use a demonstration electrode and pulse generator with fluoroscopy, prior to prepping and draping, to maximize the left ventricular mass between them. We adapted a submuscular abdominal ICD technique to implant the S-ICD intermuscularly between the anterior surface of serratus anterior and the posterior surface of latissimus dorsi. Surgery in our patients beyond the subcutaneous tissue was bloodless, as muscle layers were carefully separated but not incised, which also protected the long thoracic nerve. Two layers of muscle protect the pulse generator. We have implanted 82 consecutive patients with this technique, taking ∼65 min. All patients were converted with 65 J standard polarity shock during induced arrhythmia conversion testing, with six (7.3%) patients requiring a repositioning of the pulse generator prior to successful conversion. Seven spontaneous episodes of ventricular fibrillation were detected in three (3.6%) patients, all successfully converted back to sinus rhythm. Long-term patient outcomes have been good with low complication rates over the mean ± standard deviation 3.6 ± 1.2 years. CONCLUSION: Our intermuscular technique and implant methodology is successful for placement of the subcutaneous defibrillator pulse generator. Our technique leads to an excellent cosmetic result and high levels of patient satisfaction. Rates of first shock conversion during defibrillation testing, inappropriate shocks, and complications during follow-up compare favourably with previous published case series. There were no left arm movement limitations post-operatively.


Assuntos
Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Músculos Intermediários do Dorso/cirurgia , Implantação de Prótese/métodos , Músculos Superficiais do Dorso/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Cardioversão Elétrica/efeitos adversos , Eletrocardiografia , Feminino , Humanos , Músculos Intermediários do Dorso/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Implantação de Prótese/efeitos adversos , Músculos Superficiais do Dorso/diagnóstico por imagem , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
8.
Acta Radiol ; 58(1): 70-76, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26936899

RESUMO

BACKGROUND: Artifacts from metallic implants can hinder image interpretation in computed tomography (CT). Image quality can be improved using metal artifact reduction (MAR) techniques. PURPOSE: To evaluate the impact of a MAR algorithm on image quality of CT examinations in comparison to filtered back projection (FBP) in patients with hip prostheses. MATERIAL AND METHODS: Twenty-two patients with 25 hip prostheses who underwent clinical abdominopelvic CT on a 64-row CT were included in this retrospective study. Axial images were reconstructed with FBP and five increasing MAR levels (M30-34). Objective artifact strength (OAS) (SIart-SInorm) was assessed by region of interest (ROI) measurements in position of the strongest artifact (SIart) and in an osseous structure without artifact (SInorm) (in Hounsfield units [HU]). Two independent readers evaluated subjective image quality regarding metallic hardware, delineation of bone, adjacent muscle, and pelvic organs on a 5-point scale (1, non-diagnostic; 5, excellent image quality). Artifacts in the near field, far field, and newly induced artifacts due to the MAR technique were analyzed. RESULTS: OAS values were: M34: 243.8 ± 155.4 HU; M33: 294.3 ± 197.8 HU; M32: 340.5 ± 210.1 HU; M31: 393.6 ± 225.2 HU; M30: 446.8 ± 224.2 HU and FBP: 528.9 ± 227.7 HU. OAS values were significantly lower for M32-34 compared to FBP (P < 0.01). For overall subjective image quality, results were: FBP, 2.0 ± 0.2; M30, 2.3 ± 0.8; M31, 2.6 ± 0.5; M32, 3.0 ± 0.6; M33, 3.5 ± 0.6; and M34, 3.8 ± 0.4 (P < 0.001 for M30-M34 vs. FBP, respectively). Increasing MAR levels resulted in new artifacts in 17% of reconstructions. CONCLUSION: The investigated MAR algorithm led to a significant reduction of artifacts from metallic hip implants. The highest MAR level provided the least severe artifacts and the best overall image quality.


Assuntos
Artefatos , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Modelos Biológicos , Intensificação de Imagem Radiográfica/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Algoritmos , Simulação por Computador , Feminino , Articulação do Quadril/cirurgia , Humanos , Masculino , Metais , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Resultado do Tratamento
9.
Can Assoc Radiol J ; 68(1): 21-26, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28010910

RESUMO

PURPOSE: The study sought to assess the frequency and prognostic value of hyperattenuating adrenal glands on contrast-enhanced computed tomography (CT) scans of surgical intensive care unit (ICU) patients with acute clinical deterioration. METHODS: Eighty-eight consecutive ICU patients (63.2 ± 14.5 years of age) were included in this retrospective analysis. All patients underwent biphasic contrast-enhanced CT due to an acute clinical deterioration. Hyperattenuation of the adrenal glands was assessed subjectively and objectively. Subjective presence or absence of hyperattenuating adrenal glands was assessed by 2 blinded radiologists (J.B. and R.S.L.) in consensus. Hounsfield units (HU) were measured in the adrenal glands and in the inferior vena cava. Objective hyperattenuation was defined as HU (adrenal glands) > HU (inferior vena cava) with a 15-HU threshold. Death within 14 days following CT was set as endpoint and acquired from electronic patient data. RESULTS: Thirty-eight patients (43.2%, Group Asubj) exhibited hyperattenuation of the adrenal glands, whereas 50 patients (56.8%, Group Bsubj) did not. Concerning the objective analysis, 31 patients (35.2%, Group Aobj) exhibited hyperdense adrenal glands, whereas 53 patients (64.8%, Group Bobj) did not. Overall 27 of 88 patients (30.6%) died within 14 days following the CT examination. Lethal outcome was significantly more frequent among patients in Group Asubj and Aobj (19 of 38 patients [50.0%] and 15 of 31 patients [48.4%]) as compared with patients in Group Bsubj (8 of 50 patients [16.0%]) and Group Bobj (12 of 57 patients [21.1%]; P < .05). Subjective and objective analysis correlated significantly (P < .05). CONCLUSIONS: Hyperattenuation of adrenal glands on contrast-enhanced CT of ICU patients with acute clinical deterioration is associated with a high mortality and might serve as a prognostic marker for patients' outcome.


Assuntos
Doenças das Glândulas Suprarrenais/diagnóstico por imagem , Glândulas Suprarrenais/diagnóstico por imagem , Meios de Contraste , Unidades de Terapia Intensiva , Tomografia Computadorizada Multidetectores/métodos , Intensificação de Imagem Radiográfica/métodos , Cuidados Críticos/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
10.
Forensic Sci Med Pathol ; 13(2): 145-150, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28265799

RESUMO

The aim of this study was to evaluate the objective and subjective image quality of a novel computed tomography (CT) protocol with reduced radiation dose for body packing with 80 kVp and automated tube current modulation (ATCM) compared to a standard body packing CT protocol. 80 individuals who were examined between March 2012 and July 2015 in suspicion of ingested drug packets were retrospectively included in this study. Thirty-one CT examinations were performed using ATCM and a fixed tube voltage of 80 kVp (group A). Forty-nine CT examinations were performed using a standard protocol with a tube voltage of 120 kVp and a fixed tube current time product of 40 mAs (group B). Subjective and objective image quality and visibility of drug packets were assessed. Radiation exposure of both protocols was compared. Contrast-to-noise ratio (group A: 0.56 ± 0.36; group B: 1.13 ± 0.91) and Signal-to-noise ratio (group A: 3.69 ± 0.98; group B: 7.08 ± 2.67) were significantly lower for group A compared to group B (p < 0.001). Subjectively, image quality was decreased for group A compared to group B (2.5 ± 0.8 vs. 1.2 ± 0.4; p < 0.001). Attenuation of body packets was higher with the new protocol (group A: 362.2 ± 70.3 Hounsfield Units (HU); group B: 210.6 ± 60.2 HU; p = 0.005). Volumetric Computed Tomography Dose Index (CTDIvol) and Dose Length Product (DLP) were significantly lower in group A (CTDIvol 2.2 ± 0.9 mGy, DLP 105.7 ± 52.3 mGycm) as compared to group B (CTDIvol 2.7 ± 0.1 mGy, DLP 126.0 ± 9.7 mGycm, p = 0.002 and p = 0.01). The novel 80 kVp CT protocol with ATCM leads to a significant dose reduction compared to a standard CT body packing protocol. The novel protocol led to a diagnostic image quality and cocaine body packets were reliably detected due to the high attenuation.


Assuntos
Tráfico de Drogas , Doses de Radiação , Radiografia Abdominal , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
11.
Tumour Biol ; 37(2): 2341-51, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26373732

RESUMO

Approximately 50-70 % of patients with retroperitoneal or intraabdominal sarcoma develop a relapse after surgical therapy, including peritoneal sarcomatosis, an extremely rare site of metastatic disease which is associated with an extremely poor prognosis. Accordingly, the establishment of a permanent cell line derived from peritoneal sarcomatosis might provide a helpful tool to understand the biological behavior and to develop new therapeutic strategies. Thus, we established and characterized a liposarcoma cell line (Lipo-DUE1) from a peritoneal sarcomatosis that was permanently cultured without showing any morphological changes. Lipo-DUE1 cells exhibited a spindle-shaped morphology and positive staining for S100. Tumorigenicity was demonstrated in vitro by invasion and migration assays and in vivo by using a subcutaneous xenograft mouse model. In addition, aCGH analysis revealed concordant copy number variations on chromosome 12q in the primary tumor, peritoneal sarcomatosis, and Lipo-DUE1 cells that are commonly observed in liposarcoma. Chemotherapeutic sensitivity assays revealed a pronounced drug-resistant phenotype of Lipo-DUE1 cells to conventionally used chemotherapeutic agents. In conclusion, we describe for the first time the establishment and characterization of a liposarcoma cell line derived from a peritoneal sarcomatosis. Hence, in the future, the newly established cell line Lipo-DUE1 might serve as a useful in vitro and in vivo model to investigate the biological behavior of liposarcoma and to assess novel targeted therapies.


Assuntos
Carcinogênese/patologia , Linhagem Celular Tumoral/patologia , Lipossarcoma/patologia , Peritônio/patologia , Animais , Carcinogênese/genética , Diferenciação Celular/genética , Diferenciação Celular/fisiologia , Movimento Celular/genética , Movimento Celular/fisiologia , Variações do Número de Cópias de DNA/genética , Resistencia a Medicamentos Antineoplásicos/genética , Resistencia a Medicamentos Antineoplásicos/fisiologia , Feminino , Humanos , Lipossarcoma/genética , Camundongos , Camundongos Endogâmicos NOD , Camundongos SCID
12.
Abdom Imaging ; 40(7): 2152-8, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26048697

RESUMO

PURPOSE: The aim of this study was to evaluate the impact of a reduced tube potential (100 kVp) for non-enhanced abdominal low-dose CT on radiation dose and image quality (IQ) in the detection of body packing. METHODS: This retrospective study was approved by the local research ethics committee of our clinic. From March 2012 to July 2014, 99 subjects were referred to our institute with suspected body packing. 50 CT scans were performed using a 120 kVp protocol (group A), and 49 CTs were performed using a low-dose protocol with a tube voltage of 100 kVp (group B). Subjective and objective IQ were assessed. DLP and CTDIvol were analyzed. RESULTS: All examinations were of diagnostic IQ. Objective IQ was not significantly different between the 120 kVp and 100 kVp protocol. Mean density of solid and liquid body packets was 210 ± 60.2 HU at 120 kVp and 250.6 ± 29.7 HU at 100 kVp. Radiation dose was significantly lower in group B as compared to group A (p < 0.05). In group A, body packs were detected in 16 (32%) of the 50 patients. In group B, packets were observed in 15 (31%) of 49 patients. Laboratory analysis detected cocaine in all smuggled body packs. CONCLUSIONS: Low-tube voltage 100 kVp MDCT with automated tube current modulation in screening of illegal drugs leads to a diagnostic IQ and significant dose reduction compared to 120 kVp low-tube voltage protocols. Despite lower radiation dose, liquid and solid cocaine containers retain high attenuation and are easily detected.


Assuntos
Cocaína , Embalagem de Medicamentos/métodos , Corpos Estranhos/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Doses de Radiação , Radiografia Abdominal , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
13.
J Magn Reson Imaging ; 40(1): 84-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24123319

RESUMO

PURPOSE: To investigate non-contrast-enhanced arterial spin labeling (ASL) MRI for functional assessment of transplanted kidneys at 1.5 Tesla (T) and 3T. MATERIALS AND METHODS: This study was approved by the local ethics committee, and written informed consent was obtained from all participants. Ninety eight renal allograft recipients (mean age, 51.5 ± 14.6 years) were prospectively included in this study. ASL MRI was performed at 1.5T (n = 65) and 3T (n = 33) using a single-slice flow-sensitive alternating inversion recovery true-fast imaging with steady-state precession (FAIR True-FISP) sequence in the paracoronal plane. ASL perfusion was regional analyzed for the renal cortex on parameter maps. ASL was compared between patients with good or moderate allograft function (Group a; estimated glomerular filtration rate [eGFR] > 30 mL/min/1.73 m(2)) and patients with heavily impaired allograft function (Group b; eGFR ≤ 30 mL/min/1.73 m(2)) and correlated to renal function as determined by eGFR. RESULTS: ASL perfusion and eGFR were comparable at 1.5T (246.9 ± 66.8 mL/100 g/min and 41.9 ± 22.7 mL/min/1.73 m(2)) and 3T (236.5 ± 102.3 mL/100 g/min and 35.9 ± 22.9 mL/min/1.73 m(2)). ASL perfusion was significantly higher in group a (282.7 ± 60.8 mL/100 g/min) as compared to group b (178.2 ± 63.3 mL/100 g/min) (P < 0.0001). ASL perfusion values exhibited a significant correlation with renal function as determined by eGFR (r = 0.59; P < 0.0001). CONCLUSION: Cortical ASL perfusion values differ between patients with good or moderate allograft function and poor allograft function and correlate significantly with allograft function. Our results highlight the potential of ASL MRI for functional evaluation of renal allografts.


Assuntos
Rejeição de Enxerto/patologia , Rejeição de Enxerto/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Transplante de Rim , Angiografia por Ressonância Magnética/métodos , Artéria Renal/fisiopatologia , Circulação Renal , Velocidade do Fluxo Sanguíneo , Feminino , Rejeição de Enxerto/etiologia , Humanos , Transplante de Rim/efeitos adversos , Pessoa de Meia-Idade , Estudos Prospectivos , Artéria Renal/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Acta Radiol ; 55(1): 86-90, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23884839

RESUMO

BACKGROUND: In the past decade the number of computed tomography (CT)-guided procedures performed by interventional radiologists have increased, leading to a significantly higher radiation exposure of the interventionalist's eye lens. Because of growing concern that there is a stochastic effect for the development of lens opacification, eye lens dose reduction for operators and patients should be of maximal interest. PURPOSE: To determine the interventionalist's equivalent eye lens dose during CT-guided interventions and to relate the results to the maximum of the recommended equivalent dose limit. MATERIAL AND METHODS: During 89 CT-guided interventions (e.g. biopsies, drainage procedures, etc.) measurements of eye lens' radiation doses were obtained from a dedicated dosimeter system for scattered radiation. The sensor of the personal dosimeter system was clipped onto the side of the lead glasses which was located nearest to the CT gantry. After the procedure, radiation dose (µSv), dose rate (µSv/min) and the total exposure time (s) were recorded. RESULTS: For all 89 interventions, the median total exposure lens dose was 3.3 µSv (range, 0.03-218.9 µSv) for a median exposure time of 26.2 s (range, 1.1-94.0 s). The median dose rate was 13.9 µSv/min (range, 1.1-335.5 µSv/min). CONCLUSION: Estimating 50-200 CT-guided interventions per year performed by one interventionalist, the median dose of the eye lens of the interventional radiologist does not exceed the maximum of the ICRP-recommended equivalent eye lens dose limit of 20 mSv per year.


Assuntos
Cristalino/efeitos da radiação , Exposição Ocupacional , Radiografia Intervencionista , Tomografia Computadorizada por Raios X , Humanos , Doses de Radiação , Radiometria/instrumentação
15.
Pediatr Radiol ; 44(9): 1065-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25022489

RESUMO

BACKGROUND: Organ-specific dose reduction significantly reduces the radiation exposure of radiosensitive organs. OBJECTIVE: The purpose of this study was to assess the impact of a novel organ-specific dose reduction algorithm on image quality of pediatric chest CT. MATERIALS AND METHODS: We included 28 children (mean age 10.9 ± 4.8 years, range 3-18 years) who had contrast-enhanced chest CT on a 128-row scanner. CT was performed at 100 kV using automated tube current modulation and a novel organ-specific dose-reduction algorithm (XCare™; Siemens, Forchheim, Germany). Seven children had a previous chest CT performed on a 64-row scanner at 100 kV without organ-specific dose reduction. Subjective image quality was assessed using a five-point scale (1-not diagnostic; 5-excellent). Contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were assessed in the descending aorta. RESULTS: Overall mean subjective image quality was 4.1 ± 0.6. In the subgroup of the seven children examined both with and without organ-specific dose reduction, subjective image quality was comparable (score 4.4 ± 0.5 with organ-specific dose reduction vs. 4.4 ± 0.7 without it; P > 0.05). There was no significant difference in mean signal-to-noise ratio and contrast-to-noise ratio with organ-specific dose reduction (38.3 ± 10.1 and 28.5 ± 8.7, respectively) and without the reduction (35.5 ± 8.5 and 26.5 ± 7.8, respectively) (P > 0.05). Volume computed tomography dose index (CTDIvol) and size-specific dose estimates did not differ significantly between acquisitions with the organ-specific dose reduction (1.7 ± 0.8 mGy) and without the reduction (1.7 ± 0.8 mGy) (P > 0.05). CONCLUSION: Organ-specific dose reduction does not have an impact on image quality of pediatric chest CT and can therefore be used in clinical practice to reduce radiation dose of radiosensitive organs such as breast and thyroid gland.


Assuntos
Doses de Radiação , Proteção Radiológica/métodos , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Algoritmos , Criança , Pré-Escolar , Meios de Contraste , Feminino , Humanos , Masculino , Estudos Retrospectivos , Razão Sinal-Ruído , Tórax/efeitos da radiação
16.
Radiology ; 266(1): 218-25, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23169797

RESUMO

PURPOSE: To evaluate the feasibility of diffusion-tensor (DT) imaging at 3 T for functional assessment of transplanted kidneys. MATERIALS AND METHODS: This study was approved by the local ethics committee; written informed consent was obtained. Between August 2009 and October 2010, 40 renal transplant recipients were prospectively included in this study and examined with a clinical 3-T magnetic resonance (MR) imager. An echo-planar DT imaging sequence was performed in coronal orientation by using five b values (0, 200, 400, 600, 800 sec/mm(2)) and 20 diffusion directions. The fractional anisotropy (FA) and apparent diffusion coefficient (ADC) were determined for the cortex and medulla of the transplanted kidney. Relationships between FA, ADC, and allograft function, determined by the estimated glomerular filtration rate (eGFR), were assessed by using Pearson correlation coefficient. ADC and FA were compared between patients with good or moderate allograft function (group A; eGFR > 30 mL/min/1.73 m(2)) and patients with impaired function (group B; eGFR ≤ 30 mL/min/1.73 m(2)) by using a student t test. P < .05 indicated a statistically significant difference. RESULTS: Mean FA of the renal medulla and cortex was significantly higher in group A (0.39 ± 0.06 and 0.17 ± 0.4) compared with group B (0.27 ± 0.05 and 0.14 ± 0.03) (P < .001 and P = .009, respectively). Mean ADCs of renal cortex and medulla were significantly higher in group A than in group B (P = .007 and P = .01, respectively). In group B, mean medullary FA was significantly lower in patients whose renal function did not recover (0.22 ± 0.02) compared with those with stable allograft function at 6 months (0.29 ± 0.05, P < .001). There was significant correlation between eGFR and medullary FA (r = 0.65, P < .001), cortical ADC (r = 0.43, P = .003), and medullary ADC (r = 0.35, P = .01). CONCLUSION: DT imaging is a promising noninvasive technique for functional assessment of renal allografts. FA values in the renal medulla exhibit a good correlation with renal function.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Rejeição de Enxerto/etiologia , Rejeição de Enxerto/patologia , Nefropatias/etiologia , Nefropatias/patologia , Transplante de Rim/efeitos adversos , Transplante de Rim/patologia , Adulto , Estudos de Viabilidade , Feminino , Humanos , Testes de Função Renal/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
17.
J Magn Reson Imaging ; 37(1): 233-6, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22807237

RESUMO

PURPOSE: To evaluate the impact of renal blood flow on apparent diffusion coefficients (ADC) and fractional anisotropy (FA) using time-resolved electrocardiogram (ECG)-triggered diffusion-tensor imaging (DTI) of the human kidneys. MATERIALS AND METHODS: DTI was performed in eight healthy volunteers (mean age 29.1 ± 3.2) using a single slice coronal echoplanar imaging (EPI) sequence (3 b-values: 0, 50, and 300 s/mm(2)) at the timepoint of minimum (20 msec after R wave) and maximum renal blood flow (200 msec after R wave) at 3T. Following 2D motion correction, region of interest (ROI)-based analysis of cortical and medullary ADC- and FA-values was performed. RESULTS: ADC-values of the renal cortex at maximum blood flow (2.6 ± 0.19 × 10(-3) mm(2)/s) were significantly higher than at minimum blood flow (2.2 ± 0.11 × 10(-3) mm(2)/s) (P < 0.001), while medullary ADC-values did not differ significantly (maximum blood flow: 2.2 ± 0.18 × 10(-3) mm(2)/s; minimum blood flow: 2.15 ± 0.14 × 10(-3) mm(2)/s). FA-values of the renal medulla were significantly greater at maximal blood (0.53 ± 0.05) than at minimal blood flow (0.47 ± 0.05) (P < 0.01). In contrast, cortical FA-values were comparable at different timepoints of the cardiac cycle. CONCLUSION: ADC-values in the renal cortex as well as FA-values in the renal medulla are influenced by renal blood flow. This impact has to be considered when interpreting renal ADC- and FA-values.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Eletrocardiografia/métodos , Rim/irrigação sanguínea , Rim/patologia , Circulação Renal , Adulto , Anisotropia , Velocidade do Fluxo Sanguíneo , Difusão , Imagem Ecoplanar , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Medula Renal/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Modelos Estatísticos , Movimento (Física) , Respiração , Fatores de Tempo
18.
Acta Radiol ; 54(4): 396-400, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23436832

RESUMO

BACKGROUND: Pertinent reportable cardiac findings on non-electrocardiography (ECG)-gated chest CT examinations have become easier to detect given recent advancements in multidetector CT technology. However, those findings are easily overlooked on routine chest CT without ECG gating given residual inherent cardiac motion artifact and non-cardiac indications. PURPOSE: To describe and quantify the types of pertinent reportable cardiac findings that can be detected on chest CT examinations without ECG gating and evaluate how often they were reported. MATERIAL AND METHODS: Two radiologists retrospectively reviewed (blinded to the original interpretation) 268 consecutive routine adult chest CT examinations without ECG gating for the presence of pertinent reportable cardiac findings. Retrospective interpretations were then compared with the original radiological reports. RESULTS: One hundred and sixty-three patients (61%) had pertinent reportable cardiac findings. The findings encountered included: coronary artery disease (n = 131; 80.0%), coronary artery bypass grafts (n = 10; 6.1%), left ventricular aneurysm (n = 1; 0.6%), valve calcification (n = 131; 80.0%), valve repair/replacement (n = 5; 3.1%), pericardial effusion (n = 33; 20.2%), left atrial appendage thrombus (n = 1; 0.6%), cardiac mass (n = 1; 0.6%), and cardiac chamber enlargement (n = 29; 17.8%). On the original radiological reports 22.3% of the pertinent reportable cardiac findings, detected by the two radiologists retrospectively, were not reported. CONCLUSION: Detection of pertinent reportable cardiac findings on routine chest CT examinations without ECG gating is possible. The high volume of chest CT examinations without ECG gating represents an opportunity for radiologists to comment on the presence or absence of cardiac disease which may influence future clinical decisions.


Assuntos
Doenças Cardiovasculares/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Artefatos , Doenças Cardiovasculares/epidemiologia , Meios de Contraste , Feminino , Humanos , Achados Incidentais , Iopamidol , Masculino , Estudos Retrospectivos
19.
Acta Radiol ; 54(10): 1210-7, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23858509

RESUMO

BACKGROUND: Biexponential analysis has been used increasingly to obtain contributions of both diffusion and microperfusion to the signal decay in diffusion-weighted imaging DWI of different parts of the body. PURPOSE: To compare biexponential diffusion parameters of transplanted kidneys obtained with three different calculation methods. MATERIAL AND METHODS: DWI was acquired in 15 renal allograft recipients (eight men, seven women; mean age, 52.4 ± 14.3 years) using a paracoronal EPI sequence with 16 b-values (b = 0-750 s/mm(2)) and six averages at 1.5T. No respiratory gating was used. Three different calculation methods were used for the calculation of biexponential diffusion parameters: Fp, ADCP, and ADCD were calculated without fixing any parameter a priori (calculation method 1); ADCP was fixed to 12.0 µm(2)/ms, whereas Fp and ADCD were calculated using the biexponential model (calculation method 2); multistep approach with monoexponential fitting of the high b-value portion (b ≥ 250 s/mm(2)) for determination of ADCD and assessment of the low b intercept for determination of Fp (calculation method 3). For quantitative analysis, ROI measurements were performed on the according parameter maps. RESULTS: Mean ADCD values of the renal cortex using calculation method 1 were significantly lower than using calculation methods 2 and 3 (P < 0.001). There was a significant correlation between calculation methods 1 and 2 (r = 0.69 (P < 0.005) and calculation methods 1 and 3 (r = 0.59; P < 0.05) as well as calculation methods 2 and 3 (r = 0.98; P < 0.001). Mean Fp values of the renal cortex were higher with calculation method 1 than with calculation methods 2 and 3 (P < 0.001). For Fp, only the correlation between calculation methods 2 and 3 was significant (r = 0.98; P < 0.001). CONCLUSION: Biexponential diffusion parameters differ significantly depending on the calculation methods used for their calculation.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Transplante de Rim , Aloenxertos , Difusão , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
20.
Skeletal Radiol ; 41(5): 531-7, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-21701952

RESUMO

OBJECTIVE: To evaluate multidetector CT volumetry in the assessment of bone defect healing in comparison to histopathological findings in an animal model. MATERIALS AND METHODS: In 16 mini-pigs, a circumscribed tibial bone defect was created. Multidetector CT (MDCT) of the tibia was performed on a 64-row scanner 42 days after the operation. The extent of bone healing was estimated quantitatively by MDCT volumetry using a commercially available software programme (syngo Volume, Siemens, Germany).The volume of the entire defect (including all pixels from -100 to 3,000 HU), the nonconsolidated areas (-100 to 500 HU), and areas of osseous consolidation (500 to 3,000 HU) were assessed and the extent of consolidation was calculated. Histomorphometry served as the reference standard. RESULTS: The extent of osseous consolidation in MDCT volumetry ranged from 19 to 92% (mean 65.4 ± 18.5%). There was a significant correlation between histologically visible newly formed bone and the extent of osseous consolidation on MDCT volumetry (r = 0.82, P < 0.0001). A significant negative correlation was detected between osseous consolidation on MDCT and histological areas of persisting defect (r = -0.9, P < 0.0001). CONCLUSION: MDCT volumetry is a promising tool for noninvasive monitoring of bone healing, showing excellent correlation with histomorphometry.


Assuntos
Tomografia Computadorizada Multidetectores/métodos , Osteogênese/fisiologia , Tíbia/diagnóstico por imagem , Tíbia/fisiopatologia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/fisiopatologia , Cicatrização/fisiologia , Animais , Tomografia Computadorizada de Feixe Cônico/métodos , Feminino , Masculino , Suínos , Tíbia/patologia , Fraturas da Tíbia/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA