Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
J Synchrotron Radiat ; 2024 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-39007825

RESUMO

The ID10 beamline of the SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) synchrotron light source in Jordan was inaugurated in June 2023 and is now open to scientific users. The beamline, which was designed and installed within the European Horizon 2020 project BEAmline for Tomography at SESAME (BEATS), provides full-field X-ray radiography and microtomography imaging with monochromatic or polychromatic X-rays up to photon energies of 100 keV. The photon source generated by a 2.9 T wavelength shifter with variable gap, and a double-multilayer monochromator system allow versatile application for experiments requiring either an X-ray beam with high intensity and flux, and/or a partially spatial coherent beam for phase-contrast applications. Sample manipulation and X-ray detection systems are designed to allow scanning samples with different size, weight and material, providing image voxel sizes from 13 µm down to 0.33 µm. A state-of-the-art computing infrastructure for data collection, three-dimensional (3D) image reconstruction and data analysis allows the visualization and exploration of results online within a few seconds from the completion of a scan. Insights from 3D X-ray imaging are key to the investigation of specimens from archaeology and cultural heritage, biology and health sciences, materials science and engineering, earth, environmental sciences and more. Microtomography scans and preliminary results obtained at the beamline demonstrate that the new beamline ID10-BEATS expands significantly the range of scientific applications that can be targeted at SESAME.

2.
Int J Mol Sci ; 23(17)2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36077349

RESUMO

Radiotherapy is an important component in the treatment of lung cancer, one of the most common cancers worldwide, frequently resulting in death within only a few years of diagnosis. In order to evaluate new therapeutic approaches and compare their efficiency with regard to tumour control at a pre-clinical stage, it is important to develop standardized samples which can serve as inter-institutional outcome controls, independent of differences in local technical parameters or specific techniques. Recent developments in 3D bioprinting techniques could provide a sophisticated solution to this challenge. We have conducted a pilot project to evaluate the suitability of standardized samples generated from 3D printed human lung cancer cells in radiotherapy studies. The samples were irradiated at high dose rates using both broad beam and microbeam techniques. We found the 3D printed constructs to be sufficiently mechanically stable for use in microbeam studies with peak doses up to 400 Gy to test for cytotoxicity, DNA damage, and cancer cell death in vitro. The results of this study show how 3D structures generated from human lung cancer cells in an additive printing process can be used to study the effects of radiotherapy in a standardized manner.


Assuntos
Bioimpressão , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/radioterapia , Projetos Piloto , Impressão Tridimensional
3.
J Synchrotron Radiat ; 26(Pt 5): 1725-1732, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31490164

RESUMO

Resonant inelastic X-ray scattering (RIXS) is an extremely valuable tool for the study of elementary, including magnetic, excitations in matter. The latest developments of this technique have mostly been aimed at improving the energy resolution and performing polarization analysis of the scattered radiation, with a great impact on the interpretation and applicability of RIXS. Instead, this article focuses on the sample environment and presents a setup for high-pressure low-temperature RIXS measurements of low-energy excitations. The feasibility of these experiments is proved by probing the magnetic excitations of the bilayer iridate Sr3Ir2O7 at pressures up to 12 GPa.

4.
Proc Natl Acad Sci U S A ; 112(13): 3916-9, 2015 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-25775531

RESUMO

The physical properties of iron (Fe) at high pressure and high temperature are crucial for understanding the chemical composition, evolution, and dynamics of planetary interiors. Indeed, the inner structures of the telluric planets all share a similar layered nature: a central metallic core composed mostly of iron, surrounded by a silicate mantle, and a thin, chemically differentiated crust. To date, most studies of iron have focused on the hexagonal closed packed (hcp, or ε) phase, as ε-Fe is likely stable across the pressure and temperature conditions of Earth's core. However, at the more moderate pressures characteristic of the cores of smaller planetary bodies, such as the Moon, Mercury, or Mars, iron takes on a face-centered cubic (fcc, or γ) structure. Here we present compressional and shear wave sound velocity and density measurements of γ-Fe at high pressures and high temperatures, which are needed to develop accurate seismic models of planetary interiors. Our results indicate that the seismic velocities proposed for the Moon's inner core by a recent reanalysis of Apollo seismic data are well below those of γ-Fe. Our dataset thus provides strong constraints to seismic models of the lunar core and cores of small telluric planets. This allows us to propose a direct compositional and velocity model for the Moon's core.

5.
Phys Rev Lett ; 118(3): 035502, 2017 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-28157361

RESUMO

We present a method for the precise determination of the full elasticity tensor from a single crystal diffraction experiment using monochromatic x rays. For the two benchmark systems calcite and magnesium oxide, we show that the measurement of thermal diffuse scattering in the proximity of Bragg reflections provides accurate values of the complete set of elastic constants. This approach allows for a reliable and model-free determination of the elastic properties and can be performed together with crystal structure investigation in the same experiment.

6.
Phys Rev Lett ; 119(1): 017001, 2017 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-28731743

RESUMO

We report evidence of a nonadiabatic Kohn anomaly in boron-doped diamond, using a joint theoretical and experimental analysis of the phonon dispersion relations. We demonstrate that standard calculations of phonons using density-functional perturbation theory are unable to reproduce the dispersion relations of the high-energy phonons measured by high-resolution inelastic x-ray scattering. On the contrary, by taking into account nonadiabatic effects within a many-body field-theoretic framework, we obtain excellent agreement with our experimental data. This result indicates a breakdown of the Born-Oppenheimer approximation in the phonon dispersion relations of boron-doped diamond.

7.
Phys Chem Chem Phys ; 18(7): 5366-71, 2016 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-26818579

RESUMO

We report the microscopic view of the thermal structural stability of the magnesium intercalated fullerene polymer Mg2C60. With the application of X-ray Raman spectroscopy and X-ray diffraction, we study in detail the decomposition pathways of the polymer system upon annealing at temperatures between 300 and 700 °C. We show that there are at least two energy scales involved in the decomposition reaction. Intermolecular carbon bonds, which are responsible for the formation of a 2D fullerene polymer, are broken with a relatively modest thermal energy, while the long-range order of the original polymer remains intact. With an increased thermal energy, the crystal structure in turn is found to undergo a transition to a novel intercalated cubic phase that is stable up to the highest temperature studied here. The local structure surrounding magnesium ions gets severely modified close to, possibly at, the phase transition. We used density functional theory based calculations to study the thermodynamic and kinetic aspects of the collapse of the fullerene network, and to explain the intermediate steps as well as the reaction pathways in the break-up of this peculiar C60 intermolecular bonding architecture.

8.
Phys Chem Chem Phys ; 18(29): 19866-72, 2016 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-27389481

RESUMO

Using a combination of high resolution X-ray powder diffraction and X-ray Raman scattering spectroscopy at the B K- and Ca L2,3-edges, we analyzed the reaction products of Ca(BH4)2 after annealing at 350 °C and 400 °C under vacuum conditions. We observed the formation of nanocrystalline/amorphous CaB6 mainly and found only small contributions from amorphous B for annealing times larger than 2 h. For short annealing times of 0.5 h at 400 °C we observed neither CaB12H12 nor CaB6. The results indicate a reaction pathway in which Ca(BH4)2 decomposes to B and CaH2 and finally reacts to form CaB6. These findings confirm the potential of using Ca(BH4)2 as a hydrogen storage medium and imply the desired cycling capabilities for achieving high-density hydrogen storage materials.

9.
Phys Chem Chem Phys ; 18(7): 5397-403, 2016 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-26818950

RESUMO

We present an in situ study of the thermal decomposition of Mg(BH4)2 in a hydrogen atmosphere of up to 4 bar and up to 500 °C using X-ray Raman scattering spectroscopy at the boron K-edge and the magnesium L2,3-edges. The combination of the fingerprinting analysis of both edges yields detailed quantitative information on the reaction products during decomposition, an issue of crucial importance in determining whether Mg(BH4)2 can be used as a next-generation hydrogen storage material. This work reveals the formation of reaction intermediate(s) at 300 °C, accompanied by a significant hydrogen release without the occurrence of stable boron compounds such as amorphous boron or MgB12H12. At temperatures between 300 °C and 400 °C, further hydrogen release proceeds via the formation of higher boranes and crystalline MgH2. Above 400 °C, decomposition into the constituting elements takes place. Therefore, at moderate temperatures, Mg(BH4)2 is shown to be a promising high-density hydrogen storage material with great potential for reversible energy storage applications.

10.
J Synchrotron Radiat ; 21(Pt 4): 762-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24971972

RESUMO

Wavelength-dispersive high-resolution X-ray spectrometers often employ elastically bent crystals for the wavelength analysis. In a preceding paper [Honkanen et al. (2014). J. Synchrotron Rad. 21, 104-110] a theory for quantifying the internal stress of a macroscopically large spherically curved analyser crystal was presented. Here the theory is applied to compensate for the corresponding decrease of the energy resolution. The technique is demonstrated with a Johann-type spectrometer using a spherically bent Si(660) analyser in near-backscattering geometry, where an improvement in the energy resolution from 1.0 eV down to 0.5 eV at 9.7 keV incident photon energy was observed.

11.
Proc Natl Acad Sci U S A ; 108(23): 9342-5, 2011 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-21597000

RESUMO

Many physical and chemical properties of the light rare-earths and actinides are governed by the active role of f electrons, and despite intensive efforts the details of the mechanisms of phase stability and transformation are not fully understood. A prominent example which has attracted a lot of interest, both experimentally and theoretically over the years is the isostructural γ - α transition in cerium. We have determined by inelastic X-ray scattering, the complete phonon dispersion scheme of elemental cerium across the γ → α transition, and compared it with theoretical results using ab initio lattice dynamics. Several phonon branches show strong changes in the dispersion shape, indicating large modifications in the interactions between phonons and conduction electrons. This is reflected as well by the lattice Grüneisen parameters, particularly around the X point. We derive a vibrational entropy change ΔS(γ-α)(vib) ≈ (0.33+/-0.03)k(B), illustrating the importance of the lattice contribution to the transition. Additionally, we compare first principles calculations with the experiments to shed light on the mechanism underlying the isostructural volume collapse in cerium under pressure.


Assuntos
Cério/química , Fenômenos Químicos , Modelos Químicos , Algoritmos , Cinética , Espalhamento a Baixo Ângulo , Difração de Raios X/métodos
12.
Phys Rev Lett ; 111(7): 077801, 2013 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-23992083

RESUMO

Density-driven phase transformations are a known phenomenon in liquids. Pressure-driven transitions from an open low-density to a higher-density close-packed structure were observed for a number of systems. Here, we show a less intuitive, inverse behavior. We investigated the electronic, atomic, and dynamic structures of liquid Rb along an isothermal line at 573 K, at 1.2-27.4 GPa, by means of ab initio molecular dynamics simulations and inelastic x-ray scattering experiments. The excellent agreement of the simulations with experimental data performed up to 6.6 GPa validates the overall approach. Above 12.5 GPa, the breakdown of the nearly-free-electron model drives a transition of the pure liquid metal towards a less metallic, denser liquid, whose first coordination shell is less compact. Our study unveils the interplay between electronic, structural, and dynamic degrees of freedom along this liquid-liquid phase transition. In view of its electronic nature, we believe that this behavior is general for the first group elements, thus shedding new light into the high-pressure properties of alkali metals.

13.
Phys Rev Lett ; 110(20): 207204, 2013 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-25167445

RESUMO

We present the results of inelastic x-ray scattering for magnetite and analyze the energies and widths of the phonon modes with different symmetries in a broad range of temperature 125 < T < 293 K. The phonon modes with X(4) and Δ(5) symmetries broaden in a nonlinear way with decreasing T when the Verwey transition is approached. It is found that the maxima of phonon widths occur away from high-symmetry points, which suggests the incommensurate character of critical fluctuations. Strong phonon anharmonicity induced by electron-phonon coupling is discovered by a combination of these experimental results with ab initio calculations which take into account local Coulomb interactions at Fe ions. It (i) explains observed anomalous phonon broadening and (ii) demonstrates that the Verwey transition is a cooperative phenomenon which involves a wide spectrum of phonons coupled to the electron charge fluctuations condensing in the low-symmetry phase.

14.
Commun Phys ; 6(1): 82, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37124119

RESUMO

The Extremely Brilliant Source (EBS) is the experimental implementation of the novel Hybrid Multi Bend Achromat (HMBA) storage ring magnetic lattice concept, which has been realised at European Synchrotron Radiation Facility. We present its successful commissioning and first operation. We highlight the strengths of the HMBA design and compare them to the previous designs, on which most operational synchrotron X-ray sources are based. We report on the EBS storage ring's significantly improved horizontal electron beam emittance and other key beam parameters. EBS extends the reach of synchrotron X-ray science confirming the HMBA concept for future facility upgrades and new constructions.

15.
Int J Radiat Oncol Biol Phys ; 114(3): 478-493, 2022 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-35934161

RESUMO

PURPOSE: Synchrotron-generated microbeam radiation therapy (MRT) represents an innovative preclinical type of cancer radiation therapy with an excellent therapeutic ratio. Beyond local control, metastatic spread is another important endpoint to assess the effectiveness of radiation therapy treatment. Currently, no data exist on an association between MRT and metastasis. Here, we evaluated the ability of MRT to delay B16F10 murine melanoma progression and locoregional metastatic spread. METHODS AND MATERIALS: We assessed the primary tumor response and the extent of metastasis in sentinel lymph nodes in 2 cohorts of C57BL/6J mice, one receiving a single MRT and another receiving 2 MRT treatments delivered with a 10-day interval. We compared these 2 cohorts with synchrotron broad beam-irradiated and nonirradiated mice. In addition, using multiplex quantitative platforms, we measured plasma concentrations of 34 pro- and anti-inflammatory cytokines and frequencies of immune cell subsets infiltrating primary tumors that received either 1 or 2 MRT treatments. RESULTS: Two MRT treatments were significantly more effective for local control than a single MRT. Remarkably, the second MRT also triggered a pronounced regression of out-of-radiation field locoregional metastasis. Augmentation of CXCL5, CXCL12, and CCL22 levels after the second MRT indicated that inhibition of melanoma progression could be associated with increased activity of antitumor neutrophils and T-cells. Indeed, we demonstrated elevated infiltration of neutrophils and activated T-cells in the tumors after the second MRT. CONCLUSIONS: Our study highlights the importance of monitoring metastasis after MRT and provides the first MRT fractionation schedule that promotes local and locoregional control with the potential to manage distant metastasis.


Assuntos
Melanoma , Síncrotrons , Animais , Citocinas , Melanoma/radioterapia , Camundongos , Camundongos Endogâmicos C57BL , Síndrome , Linfócitos T
16.
Int J Radiat Oncol Biol Phys ; 113(5): 967-973, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35483539

RESUMO

PURPOSE: The high potential of microbeam radiation therapy (MRT) in improving tumor control while reducing side effects has been shown by numerous preclinical studies. MRT offers a widened therapeutic window by using the periodical spatial fractionation of synchrotron generated x-rays into an array of intense parallel microbeams. MRT now enters a clinical transfer phase. As proof of principle and cornerstone for the safe clinical transfer of MRT, we conducted a "first in dog" trial under clinical conditions. In this report, we evaluated whether a 3-dimensional conformal MRT can be safely delivered as exclusive radiosurgical treatment in animal patients METHODS AND MATERIALS: We irradiated a 17.5-kg French bulldog for a spontaneous brain tumor (glioma suspected on magnetic resonance imaging) with conformal high-dose-rate microbeam arrays (50-µm-wide microbeams, replicated with a pitch of 400 µm) of synchrotron-generated x-rays. The dose prescription adjusted a minimal cumulated valley dose of 2.8 Gy to the plnning target volume (PTV) (cinical target volume (CTV)+ 1 mm). Thus, each beam delivered 20 to 25 Gy to the target as peak doses, and ∼1 Gy as valley doses RESULTS: The treatment was successfully delivered. Clinical follow-up over 3 months showed a significant improvement of the dog's quality of life: the symptoms disappeared. Magnetic resonance imaging, performed 3 months after irradiation, revealed reduction in tumor size (-87.4%) and mass effect with normalization of the left lateral ventricle. CONCLUSIONS: To our knowledge, this neuro-oncologic veterinary trial is the first 3-dimensional conformal synchrotron x-ray MRT treatment of a spontaneous intracranial tumor in a large animal. It is an essential last step toward the clinical transfer of MRT in the near future to demonstrate the feasibility and safety of treating deep-seated tumors using synchrotron-generated microbeams.


Assuntos
Neoplasias Encefálicas , Glioma , Radiocirurgia , Animais , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/veterinária , Cães , Glioma/diagnóstico por imagem , Glioma/patologia , Glioma/radioterapia , Qualidade de Vida , Radiocirurgia/métodos , Síncrotrons
17.
Cancers (Basel) ; 13(9)2021 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-33925455

RESUMO

BACKGROUND: Microbeam Radiation Therapy (MRT) induces a transient vascular permeability window, which offers a novel drug-delivery system for the preferential accumulation of therapeutic compounds in tumors. MRT is a preclinical cancer treatment modality that spatially fractionates synchrotron X-rays into micrometer-wide planar microbeams which can induce transient vascular permeability, especially in the immature tumor vessels, without compromising vascular perfusion. Here, we characterized this phenomenon using Chicken Chorioallantoic Membrane (CAM) and demonstrated its therapeutic potential in human glioblastoma xenografts in mice. METHODS: the developing CAM was exposed to planar-microbeams of 75 Gy peak dose with Synchrotron X-rays. Similarly, mice harboring human glioblastoma xenografts were exposed to peak microbeam doses of 150 Gy, followed by treatment with Cisplatin. Tumor progression was documented by Magnetic Resonance Imaging (MRI) and caliper measurements. RESULTS: CAM exposed to MRT exhibited vascular permeability, beginning 15 min post-irradiation, reaching its peak from 45 min to 2 h, and ending by 4 h. We have deemed this period the "permeability window". Morphological analysis showed partially fragmented endothelial walls as the cause of the increased transport of FITC-Dextran into the surrounding tissue and the extravasation of 100 nm microspheres (representing the upper range of nanoparticles). In the human glioblastoma xenografts, MRI measurements showed that the combined treatment dramatically reduced the tumor size by 2.75-fold and 5.25-fold, respectively, compared to MRT or Cisplatin alone. CONCLUSIONS: MRT provides a novel mechanism for drug delivery by increasing vascular transpermeability while preserving vessel integrity. This permeability window increases the therapeutic index of currently available chemotherapeutics and could be combined with other therapeutic agents such as Nanoparticles/Antibodies/etc.

18.
Cancers (Basel) ; 13(5)2021 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-33668110

RESUMO

Delivery of high-radiation doses to brain tumors via multiple arrays of synchrotron X-ray microbeams permits huge therapeutic advantages. Brain tumor (9LGS)-bearing and normal rats were irradiated using a conventional, homogeneous Broad Beam (BB), or Microbeam Radiation Therapy (MRT), then studied by behavioral tests, MRI, and histopathology. A valley dose of 10 Gy deposited between microbeams, delivered by a single port, improved tumor control and median survival time of tumor-bearing rats better than a BB isodose. An increased number of ports and an accumulated valley dose maintained at 10 Gy delayed tumor growth and improved survival. Histopathologically, cell death, vascular damage, and inflammatory response increased in tumors. At identical valley isodose, each additional MRT port extended survival, resulting in an exponential correlation between port numbers and animal lifespan (r2 = 0.9928). A 10 Gy valley dose, in MRT mode, delivered through 5 ports, achieved the same survival as a 25 Gy BB irradiation because of tumor dose hot spots created by intersecting microbeams. Conversely, normal tissue damage remained minimal in all the single converging extratumoral arrays. Multiport MRT reached exceptional ~2.5-fold biological equivalent tumor doses. The unique normal tissue sparing and therapeutic index are eminent prerequisites for clinical translation.

19.
Cancers (Basel) ; 12(9)2020 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-32957691

RESUMO

BACKGROUND: Synchrotron Microbeam Radiotherapy (MRT) significantly improves local tumour control with minimal normal tissue toxicity. MRT delivers orthovoltage X-rays at an ultra-high "FLASH" dose rate in spatially fractionated beams, typically only few tens of micrometres wide. One of the biggest challenges in translating MRT to the clinic is its use of high peak doses, of around 300-600 Gy, which can currently only be delivered by synchrotron facilities. Therefore, in an effort to improve the translation of MRT to the clinic, this work studied whether the temporal fractionation of traditional MRT into several sessions with lower, more clinically feasible, peak doses could still maintain local tumour control. METHODS: Two groups of twelve C57Bl/6J female mice harbouring B16-F10 melanomas in their ears were treated with microbeams of 50 µm in width spaced by 200 µm from their centres. The treatment modality was either (i) a single MRT session of 401.23 Gy peak dose (7.40 Gy valley dose, i.e., dose between beams), or (ii) three MRT sessions of 133.41 Gy peak dose (2.46 Gy valley dose) delivered over 3 days in different anatomical planes, which intersected at 45 degrees. The mean dose rate was 12,750 Gy/s, with exposure times between 34.2 and 11.4 ms, respectively. RESULTS: Temporally fractionated MRT ablated 50% of B16-F10 mouse melanomas, preventing organ metastases and local tumour recurrence for 18 months. In the rest of the animals, the median survival increased by 2.5-fold in comparison to the single MRT session and by 4.1-fold with respect to untreated mice. CONCLUSIONS: Temporally fractionating MRT with lower peak doses not only maintained tumour control, but also increased the efficacy of this technique. These results demonstrate that the solution to making MRT more clinically feasible is to irradiate with several fractions of intersecting arrays with lower peak doses. This provides alternatives to synchrotron sources where future microbeam radiotherapy could be delivered with less intense radiation sources.

20.
Phys Med ; 71: 161-167, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32163884

RESUMO

The use of synchrotron X-ray sources provides innovative approaches in radiation therapy. The unique possibility to generate quasi-parallel beams promoted the development of microbeam radiation therapy (MRT), an innovative approach able to reduce damages to normal tissues while delivering considerable doses in the lesion. Accurate dosimetry in broad-beam configuration (prior to the spatial fractionation of the incident X-ray fan) is very challenging at ultra-high dose rate synchrotron sources. The available reference dosimetry protocol based on the use of a PTW PinPoint ionization chamber was compared with alanine dosimetry at the European Synchrotron Radiation Facility (ESRF) ID17 Biomedical beamline, an orthovoltage X-ray source with an average dose rate of 11.6 kGy/s. Reference dose measurements of the alanine pellets were performed at the National Centre for Radiation Research and Technology (NCRRT) 60Co facility in Egypt. All alanine dosimeters were analysed by an electron paramagnetic resonance spectrometer. We determined a relative response rESRF = 0.932 ± 0.027 (1σ) of the alanine pellets irradiated at the ESRF compared to the 60Co facility. Considering the appropriate corrections for the ESRF polychromatic spectrum and the different field size used, our result is in agreement with the previous work of Waldeland et al. for which the utilised alanine contained the same amount of binder, and it is consistent with the works of Anton et al. and Butler et al. for which the utilised alanine contained a higher amount of binder. We confirm that alanine is an appropriate dosimeter for ultra-high dose rate calibration of orthovoltage X-ray sources.


Assuntos
Alanina , Dosímetros de Radiação , Radiometria/métodos , Dosagem Radioterapêutica , Síncrotrons , Algoritmos , Radioisótopos de Cobalto , Espectroscopia de Ressonância de Spin Eletrônica , Fótons , Reprodutibilidade dos Testes , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA