Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
1.
J Proteome Res ; 23(1): 465-482, 2024 01 05.
Artigo em Inglês | MEDLINE | ID: mdl-38147655

RESUMO

Temozolomide (TMZ) is the first line of chemotherapy to treat primary brain tumors of the type glioblastoma multiforme (GBM). TMZ resistance (TMZR) is one of the main barriers to successful treatment and is a principal factor in relapse, resulting in a poor median survival of 15 months. The present paper focuses on proteomic analyses of cytosolic fractions from TMZ-resistant (TMZR) LN-18 cells. The experimental workflow includes an easy, cost-effective, and reproducible method to isolate subcellular fraction of cytosolic (CYTO) proteins, mitochondria, and plasma membrane proteins for proteomic studies. For this study, enriched cytoplasmic fractions were analyzed in replicates by nanoflow liquid chromatography tandem high-resolution mass spectrometry (nLC-MS/MS), and proteins identified were quantified using a label-free approach (LFQ). Statistical analysis of control (CTRL) and temozolomide-resistant (TMZR) proteomes revealed proteins that appear to be differentially controlled in the cytoplasm. The functions of these proteins are discussed as well as their roles in other cancers and TMZ resistance in GBM. Key proteins are also described through biological processes related to gene ontology (GO), molecular functions, and cellular components. For protein-protein interactions (PPI), network and pathway involvement analyses have been performed, highlighting the roles of key proteins in the TMZ resistance phenotypes. This study provides a detailed insight into methods of subcellular fractionation for proteomic analysis of TMZ-resistant GBM cells and the potential to apply this approach to future large-scale studies. Several key proteins, protein-protein interactions (PPI), and pathways have been identified, underlying the TMZ resistance phenotype and highlighting the proteins' biological functions.


Assuntos
Neoplasias Encefálicas , Glioblastoma , Humanos , Temozolomida/farmacologia , Temozolomida/uso terapêutico , Glioblastoma/patologia , Proteômica , Espectrometria de Massas em Tandem , Antineoplásicos Alquilantes/farmacologia , Antineoplásicos Alquilantes/uso terapêutico , Linhagem Celular Tumoral , Recidiva Local de Neoplasia , Citoplasma/metabolismo , Resistencia a Medicamentos Antineoplásicos , Neoplasias Encefálicas/genética
2.
J Proteome Res ; 23(4): 1360-1369, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38457694

RESUMO

Trypsin is the gold-standard protease in bottom-up proteomics, but many sequence stretches of the proteome are inaccessible to trypsin and standard LC-MS approaches. Thus, multienzyme strategies are used to maximize sequence coverage in post-translational modification profiling. We present fast and robust SP3- and STRAP-based protocols for the broad-specificity proteases subtilisin, proteinase K, and thermolysin. All three enzymes are remarkably fast, producing near-complete digests in 1-5 min, and cost 200-1000× less than proteomics-grade trypsin. Using FragPipe resolved a major challenge by drastically reducing the duration of the required "unspecific" searches. In-depth analyses of proteinase K, subtilisin, and thermolysin Jurkat digests identified 7374, 8178, and 8753 unique proteins with average sequence coverages of 21, 29, and 37%, including 10,000s of amino acids not reported in PeptideAtlas' >2400 experiments. While we could not identify distinct cleavage patterns, machine learning could distinguish true protease products from random cleavages, potentially enabling the prediction of cleavage products. Finally, proteinase K, subtilisin, and thermolysin enabled label-free quantitation of 3111, 3659, and 4196 unique Jurkat proteins, which in our hands is comparable to trypsin. Our data demonstrate that broad-specificity proteases enable quantitative proteomics of uncharted areas of the proteome. Their fast kinetics may allow "on-the-fly" digestion of samples in the future.


Assuntos
Peptídeo Hidrolases , Proteômica , Peptídeo Hidrolases/metabolismo , Tripsina/metabolismo , Proteoma/análise , Endopeptidase K , Termolisina , Subtilisinas
3.
J Proteome Res ; 23(4): 1488-1494, 2024 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-38530092

RESUMO

We studied the effect of the column temperature on the selectivity of reversed-phase peptide separation in bottom-up proteomics. The number of peptide identifications from 2 h liquid chromatography with tandem mass spectrometry (LC-MS/MS) acquisitions reaches a plateau at 45-55 °C, driven simultaneously by improved separation efficiency, a gradual decrease in peptide retention, and possible on-column degradation of peptides at elevated temperatures. Performing 2D LC-MS/MS acquisitions at 25, 35, 45, and 55 °C resulted in the identification of ∼100,000 and ∼120,000 unique peptides for nonmodified and tandem mass tags (TMT)-labeled samples, respectively. These peptide collections were used to investigate the temperature-driven retention features. The latter is governed by the specific temperature response of individual residues, peptide hydrophobicity and length, and amphipathic helicity. On average, peptide retention decreased by 0.56 and 0.5% acetonitrile for each 10 °C increase for label-free and TMT-labeled peptides, respectively. This generally linear response of retention shifts allowed the extrapolation of predictive models beyond the studied temperature range. Thus, (trap) column cooling from room temperature to 0 °C will allow the retention of an additional 3% of detectable tryptic peptides. Meanwhile, the application of 90 °C would result in the loss of ∼20% of tryptic peptides that were amenable to MS/MS-based identification.


Assuntos
Peptídeos , Espectrometria de Massas em Tandem , Cromatografia Líquida/métodos , Temperatura , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos , Peptídeos/química
4.
Anal Chem ; 96(23): 9721-9728, 2024 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-38807522

RESUMO

Can reversed-phase peptide retention be the same for C8 and C18 columns? or increase for otherwise identical columns with a smaller surface area? Can replacing trifluoroacetic acid (TFA) with formic acid (FA) improve the peak shape? According to our common understanding of peptide chromatography, absolutely not. Surprisingly, a thorough comparison of the peptide separation selectivity of 100 and 120 Šfully porous C18 sorbents to maximize the performance of our in-house proteomics LC-MS/MS setup revealed an unexpectedly higher peptide retentivity for a wider pore packing material, despite it having a smaller surface area. Concurrently, the observed increase in peptide retention─which drives variation in separation selectivity between 100 and 120 Špore size materials─was more pronounced for smaller peptides. These findings contradict the central dogmas that underlie the development of all peptide RP-HPLC applications: (i) a larger surface area leads to higher retention and (ii) increasing the pore size should benefit the retention of larger analytes. Based on our intriguing findings, we compared reversed-phase high-performance liquid chromatography peptide retention for a total of 20 columns with pore sizes between 60 and 300 Šusing FA- and TFA-based eluents. Our results unequivocally attest that the larger size of ion pairs in FA- vs TFA-based eluents leads to the observed impact on selectivity and peptide retention. For FA, peptide retention peaks at 200 Špore size, compared to between 120 and 200 Šfor TFA. However, the decrease in retention for narrow-pore particles is more profound in FA. Our findings suggest that common assumptions about analyte size and accessible surface area should be revisited for ion-pair RP separation of small peptides, typical for proteomic applications that are predominantly applying FA eluents. Hybrid silica-based materials with pore sizes of 130-200 Šshould be specifically targeted for bottom-up proteomic applications to obtain both superior peak shape and peptide retentivity. This challenging task of attaining the best RPLC column for proteomics calls for closer collaboration between LC column manufacturers and proteomic LC specialists.


Assuntos
Cromatografia de Fase Reversa , Peptídeos , Proteômica , Proteômica/métodos , Peptídeos/química , Peptídeos/análise , Peptídeos/isolamento & purificação , Porosidade , Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão , Tamanho da Partícula , Ácido Trifluoracético/química , Propriedades de Superfície
5.
J Proteome Res ; 22(1): 272-278, 2023 01 06.
Artigo em Inglês | MEDLINE | ID: mdl-36480176

RESUMO

Despite the general acceptance of formic acid as the additive of choice for peptide reversed-phase LC-MS/MS applications, some still argue that the selection of acetic acid represents a better option. To settle this debate, we investigated both the difference in MS sensitivity and chromatographic behavior of peptides between these two systems. This interlaboratory study was performed using different MS setups and C18 separation media employing both 0.1% formic and 0.5% acetic acid as ion pairing modifiers. Relative to formic acid, we find an overall ∼2.2-2.5× increase in MS signal and a slight decrease in RP LC retention (-0.7% acetonitrile on average) for acetic acid conditions. While these two features have opposing effects on peptide detectability, we find that acetic acid produces up to 60% higher peptide ID output depending on the type of sample. The drop in RPLC retention increases with peptide net charge at acidic pH. MS signal is dependent on the difference between the charge of the precursor ion and the charge of the peptide in solution, favoring species with a low pI. Lower peptide retention under acetic acid conditions demonstrates its higher hydrophilicity and, as expected, leads to composition and sequence-dependent character of the observed retention shift.


Assuntos
Ácido Acético , Proteômica , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem , Peptídeos/análise
6.
Anal Chem ; 95(39): 14634-14642, 2023 10 03.
Artigo em Inglês | MEDLINE | ID: mdl-37739932

RESUMO

We have systematically evaluated the chromatographic behavior of post-translationally/chemically modified peptides using data spanning over 70 of the most relevant modifications. These retention properties were measured for standard bottom-up proteomic settings (fully porous C18 separation media, 0.1% formic acid as ion-pairing modifier) using collections of modified/nonmodified peptide pairs. These pairs were generated by spontaneous degradation, chemical or enzymatic treatment, analysis of synthetic peptides, or the cotranslational incorporation of noncanonical proline analogues. In addition, these measurements were validated using external data acquired for synthetic peptides and enzymatically induced citrullination. Working in units of hydrophobicity index (HI, % ACN) and evaluating the average retention shifts (ΔHI) represent the simplest approach to describe the effect of modifications from a didactic point of view. Plotting HI values for modified (y-axis) vs nonmodified (x-axis) counterparts generates unique slope and intercept values for each modification defined by the chemistry of the modifying moiety: its hydrophobicity, size, pKa of ionizable groups, and position of the altered residue. These composition-dependent correlations can be used for coarse incorporation of PTMs into models for prediction of peptide retention. More accurate predictions would require the development of specific sequence-dependent algorithms to predict ΔHI values.


Assuntos
Peptídeos , Proteômica , Proteômica/métodos , Cromatografia Líquida de Alta Pressão/métodos , Peptídeos/química , Cromatografia de Fase Reversa/métodos
7.
J Proteome Res ; 21(5): 1218-1228, 2022 05 06.
Artigo em Inglês | MEDLINE | ID: mdl-35363494

RESUMO

We present the first detailed study of chromatographic behavior of peptides labeled with tandem mass tags (TMT and TMTpro) in 2D LC for proteomic applications. Carefully designed experimental procedures have permitted generating data sets of over 100,000 nonlabeled and TMT-labeled peptide pairs for the low pH RP in the second separation dimension and data sets of over 10,000 peptide pairs for high-pH RP, HILIC (amide and silica), and SCX separations in the first separation dimension. The average increase in peptide RPLC (0.1% formic acid) retention upon TMT labeling was found to be 3.3% acetonitrile (linear water/acetonitrile gradients), spanning a range of -4 to 10.3%. In addition to the bulk peptide properties such as length, hydrophobicity, and the number of labeled residues, we found several sequence-dependent features mostly associated with differences in N-terminal chemistry. The behavior of TMTpro-labeled peptides was found to be very similar except for a slightly higher hydrophobicity: an average retention shift of 3.7% acetonitrile. The respective versions of the sequence-specific retention calculator (SSRCalc) model have been developed to accommodate both TMT chemistries, showing identical prediction accuracy (R2 ∼ 0.98) for labeled and nonlabeled peptides. Higher retention for TMT-labeled peptides was observed for high-pH RP and HILIC separations, while SCX selectivity remained virtually unchanged.


Assuntos
Proteômica , Espectrometria de Massas em Tandem , Acetonitrilas/química , Cromatografia Líquida , Peptídeos/análise , Proteômica/métodos
8.
J Proteome Res ; 21(12): 2846-2892, 2022 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-36355445

RESUMO

The performance of the current bottom-up liquid chromatography hyphenated with mass spectrometry (LC-MS) analyses has undoubtedly been fueled by spectacular progress in mass spectrometry. It is thus not surprising that the MS instrument attracts the most attention during LC-MS method development, whereas optimizing conditions for peptide separation using reversed-phase liquid chromatography (RPLC) remains somewhat in its shadow. Consequently, the wisdom of the fundaments of chromatography is slowly vanishing from some laboratories. However, the full potential of advanced MS instruments cannot be achieved without highly efficient RPLC. This is impossible to attain without understanding fundamental processes in the chromatographic system and the properties of peptides important for their chromatographic behavior. We wrote this tutorial intending to give practitioners an overview of critical aspects of peptide separation using RPLC to facilitate setting the LC parameters so that they can leverage the full capabilities of their MS instruments. After briefly introducing the gradient separation of peptides, we discuss their properties that affect the quality of LC-MS chromatograms the most. Next, we address the in-column and extra-column broadening. The last section is devoted to key parameters of LC-MS methods. We also extracted trends in practice from recent bottom-up proteomics studies and correlated them with the current knowledge on peptide RPLC separation.


Assuntos
Cromatografia de Fase Reversa , Proteômica , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa/métodos , Espectrometria de Massas/métodos , Peptídeos/análise , Proteômica/métodos
9.
J Proteome Res ; 20(3): 1571-1581, 2021 03 05.
Artigo em Inglês | MEDLINE | ID: mdl-33523662

RESUMO

The chromatographic behavior of peptides carrying citrulline and homocitrulline residues in proteomic two-dimensional (2D) liquid chromatography-mass spectrometry (LC-MS) experiments has been investigated. The primary goal of this study was to determine the chromatographic conditions that allow differentiating between arginine citrullination and deamidation of asparagine based on retention data, improving the confidence of MS-based identifications. Carbamylation was used as a reference point due to a high degree of similarity between modification products and anticipated changes in chromatographic behavior. We applied 2D LC-MS/MS (a high-pH-low-pH reversed phase (RP), hydrophilic interaction liquid chromatography (HILIC)-low-pH RP, and strong cation exchange (SCX)-low-pH RP) to acquire retention data for modified-nonmodified peptide pairs in the four separation modes. Modifications of a standard protein mixture were induced enzymatically (PAD-2) or chemically (urea) for citrullination and carbamylation, respectively. Deamidation occurs spontaneously. Similar retention shifts were observed for all three modifications in a high-pH RP (decrease) and a low-pH RP (increase), thus limiting the applicability of this 2D LC combination. HILIC on bare silica and strong cation exchange separations have been probed to amplify the effect of charge loss upon citrullination, with SCX demonstrating the most differentiating power: the elimination of basic residues upon citrullination/carbamylation results in an ∼58 mM KCl retention decrease, while retention of deamidated products decreases slightly.


Assuntos
Citrulinação , Espectrometria de Massas em Tandem , Cromatografia Líquida , Peptídeos , Carbamilação de Proteínas , Proteômica
10.
J Proteome Res ; 2021 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-34133192

RESUMO

The contribution of peptide amino acid sequence to collision cross section values (CCS) has been investigated using a dataset of ∼134 000 peptides of four different charge states (1+ to 4+). The migration data were acquired using a two-dimensional liquid chromatography (LC)/trapped ion mobility spectrometry/quadrupole/time-of-flight mass spectrometry (MS) analysis of HeLa cell digests created using seven different proteases and was converted to CCS values. Following the previously reported modeling approaches using intrinsic size parameters (ISP), we extended this methodology to encode the position of individual residues within a peptide sequence. A generalized prediction model was built by dividing the dataset into eight groups (four charges for both tryptic/nontryptic peptides). Position-dependent ISPs were independently optimized for the eight subsets of peptides, resulting in prediction accuracy of ∼0.981 for the entire population of peptides. We find that ion mobility is strongly affected by the peptide's ability to solvate the positively charged sites. Internal positioning of polar residues and proline leads to decreased CCS values as they improve charge solvation; conversely, this ability decreases with increasing peptide charge due to electrostatic repulsion. Furthermore, higher helical propensity and peptide hydrophobicity result in a preferential formation of extended structures with higher than predicted CCS values. Finally, acidic/basic residues exhibit position-dependent ISP behavior consistent with electrostatic interaction with the peptide macrodipole, which affects the peptide helicity. The MS raw data files have been deposited with the ProteomeXchange Consortium via the jPOST partner repository (http://jpostdb.org) with the dataset identifiers PXD021440/JPST000959, PXD022800/JPST001017, and PXD026087/ JPST001176.

11.
FEMS Yeast Res ; 21(2)2021 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-33571365

RESUMO

Oleaginous yeasts have the ability to store greater than 20% of their mass as neutral lipids, in the form of triacylglycerides. The ATP citrate lyase is thought to play a key role in triacylglyceride synthesis, but the relationship between expression levels of this and other related enzymes is not well understood in the role of total lipid accumulation conferring the oleaginous phenotype. We conducted comparative proteomic analyses with the oleaginous yeast, Yarrowia lipolytica, grown in either nitrogen-sufficient rich media or nitrogen-limited minimal media. Total proteins extracted from cells collected during logarithmic and late stationary growth phases were analyzed by 1D liquid chromatography, followed by mass spectroscopy. The ATP citrate lyase enzyme was expressed at similar concentrations in both conditions, in both logarithmic and stationary phase, but many upstream and downstream enzymes showed drastically different expression levels. In non-lipogenic conditions, several pyruvate enzymes were expressed at higher concentration. These enzymes, especially the pyruvate decarboxylase and pyruvate dehydrogenase, may be regulating carbon flux away from central metabolism and reducing the amount of citrate being produced in the mitochondria. While crucial for the oleaginous phenotype, the constitutively expressed ATP citrate lyase appears to cleave citrate in response to carbon flux upstream from other enzymes creating the oleaginous phenotype.


Assuntos
Expressão Gênica , Metabolismo dos Lipídeos/genética , Lipídeos/genética , Nitrogênio/metabolismo , Proteoma/genética , Yarrowia/genética , Yarrowia/metabolismo , Simulação por Computador , Proteínas Fúngicas/genética , Proteínas Fúngicas/metabolismo , Proteoma/análise , Proteômica/métodos , Yarrowia/química
12.
Anal Chem ; 92(5): 3904-3912, 2020 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-32030975

RESUMO

Peptide separation orthogonality for 16 different 2D LC-ESI MS systems has been evaluated. To compare and contrast the behavior of the first dimension columns, a large proteomic retention data set of ∼30 000 tryptic peptides was collected for each 2D pairing. The selection of the first dimension system was made to cover the most popular peptide separation modes applied in proteomics: reversed-phase (RP) separations with different pH, hydrophilic interaction liquid chromatography (HILIC), strong cation and anion exchange (SCX, SAX), and mixed-mode separations. The separation orthogonality generally increases in the order RP < SCX < HILIC < SAX, with the exception of high pH RP-low pH RP system, which showed the second best orthogonality value (68%), just behind PolySAX LP column (74%). The identification output of the 2D LC-MS/MS system is driven by both separation orthogonality and efficiency, making high pH RP the best choice for the first dimension separation. Its performance in combination with a standard C18 at acidic pH can be increased further through the application of pairwise fraction concatenation. The effect of the latter has been evaluated using in silico fraction concatenation, which has been proven to show improvement only for RP separations in the first dimension. Concatenation of two, three, and four-five fractions into one is shown to be the most effective for high pH RP and HFBA- and TFA-based C18 separations, respectively. We also suggest simple guidelines for the unbiased determination of dissimilarity for two separation dimensions and evaluate separation orthogonality in 3D LC-LC-MS separation space for all systems under investigation.


Assuntos
Peptídeos/análise , Proteômica/métodos , Animais , Bovinos , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia de Fase Reversa , Interações Hidrofóbicas e Hidrofílicas , Soroalbumina Bovina/química , Soroalbumina Bovina/metabolismo , Espectrometria de Massas em Tandem , Tripsina/metabolismo
13.
J Sep Sci ; 43(20): 3830-3839, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32818315

RESUMO

Separation selectivity and detection sensitivity of reversed-phase high-performance liquid chromatography with tandem mass spectrometry analyses were compared for formic (0.1%) and formic/heptafluorobutyric (0.1%/0.005%) acid based eluents using a proteomic data set of ∼12 000 paired peptides. The addition of a small amount of hydrophobic heptafluorobutyric acid ion-pairing modifier increased peptide retention by up to 10% acetonitrile depending on peptide charge, size, and hydrophobicity. Retention increase was greatest for peptides that were short, highly charged, and hydrophilic. There was an ∼3.75-fold reduction in MS signal observed across the whole population of peptides following the addition of heptafluorobutyric acid. This resulted in ∼36% and ∼21% reduction of detected proteins and unique peptides for the whole cell lysate digests, respectively. We also confirmed that the separation selectivity of the formic/heptafluorobutyric acid system was very similar to the commonly used conditions of 0.1% trifluoroacetic acid, and developed a new version of the Sequence-Specific Retention calculator model for the formic/heptafluorobutyric acid system showing the same ∼0.98 R2 -value accuracy as the Sequence-Specific Retention calculator formic acid model. In silico simulation of peptide distribution in separation space showed that the addition of 0.005% heptafluorobutyric acid to the 0.1% formic acid system increased potential proteome coverage by ∼11% of detectable species (tryptic peptides ≥ four amino acids).


Assuntos
Butiratos/química , Formiatos/química , Peptídeos/isolamento & purificação , Proteômica , Cromatografia Líquida , Íons/química , Espectrometria de Massas , Peptídeos/química
14.
Anal Chem ; 91(21): 13360-13366, 2019 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-31566965

RESUMO

The sequence-specific retention calculator algorithm (SSRCalc) [ Krokhin , O. V. Anal. Chem. 2006 , 78 , 7785 ] was adapted for the prediction of retention times of N-glycopeptides separated by reversed-phase high performance liquid chromatography (RPLC). The retention time shifts (dHI = HIglyco - HIdeglyco, where HI is the hydrophobicity index, measured in percent acetonitrile units) used for modeling were measured for 602 glycopeptides versus 123 of their deglycosylated analogues. Our method used a tryptic digest of 12 purified glycoproteins, glycopeptide enrichment, deglycosylation with PNGaseF, and RPLC-MS/MS analysis of combined (deglycosylated and intact) peptide mixtures. On average, glycosylation yields a 0.79% acetonitrile unit decrease in retention, compared with the hydrophobicity indices of their deglycosylated analogues. These values, however, are drastically different for asialo (-1.37% acetonitrile units), monosialylated (-0.47% acetonitrile units), disialylated (+0.61% acetonitrile units), and trisialylated (+1.94% acetonitrile units) glycans. Peptide retention time shifts upon glycosylation (dHI) vary depending on the number of monosaccharide units, the presence or absence of sialic acid, peptide hydrophobicity, and the number of position-dependent features. These features are mostly driven by competing effects of acidic residues (aspartic acid and sialic acid) on ion-pair formation and by nearest-neighbor effects of hydrophilic glycans. The accuracy of the modified prediction model for glycopeptides approaches that of the prediction for nonmodified species (R2 = 0.97 vs 0.98). However, retention time prediction based on the experimental retention values of deglycosylated analogues (HIglyco = HIdeglyco + dHI, R2 = 0.995) is much more accurate, thus providing a solid support for glycopeptide identification in complex samples based on mass and retention time.


Assuntos
Cromatografia de Fase Reversa/métodos , Glicopeptídeos/química , Proteômica/métodos , Animais , Bovinos , Glicosilação , Humanos , Fatores de Tempo
15.
Anal Chem ; 91(3): 2201-2208, 2019 02 05.
Artigo em Inglês | MEDLINE | ID: mdl-30624053

RESUMO

Phosphoproteomics requires better separation of phosphopeptides to boost the coverage of the phosphoproteome. We argue that an alternative separation method that produces orthogonal phosphopeptide separation to the widely used LC needs to be considered. Capillary zone electrophoresis (CZE) is one important alternative because CZE and LC are orthogonal for phosphopeptide separation and because the migration time of peptides in CZE can be accurately predicted. In this work, we coupled strong cation exchange (SCX)-reversed-phase LC (RPLC) to CZE-MS/MS for large-scale phosphoproteomics of the colon carcinoma HCT116 cell line. The CZE-MS/MS-based platform identified 11,555 phosphopeptides. The phosphopeptide data set is at least 100% larger than that from previous CZE-MS/MS studies and will be a valuable resource for building a model for predicting the migration time of phosphopeptides in CZE. Phosphopeptides migrate significantly slower than corresponding unphosphopeptides under acidic conditions of CZE separations and in a normal polarity. According to our modeling data, phosphorylation decreases peptide's charge roughly by one charge unit, resulting in dramatic decrease in electrophoretic mobility. Preliminary investigations demonstrate that electrophoretic mobility of phosphopeptides containing one phosphoryl group can be predicted with the same accuracy as for nonmodified peptides ( R2 ≈ 0.99). The CZE-MS/MS and LC-MS/MS were complementary in large-scale phosphopeptide identifications and produced different phosphosite motifs from the HCT116 cell line. The data highlight the value of CZE-MS/MS for phosphoproteomics as a complementary separation approach for not only improving the phosphoproteome coverage but also providing more insight into the phosphosite motifs.


Assuntos
Fosfopeptídeos/análise , Proteoma/análise , Proteômica/métodos , Sequência de Aminoácidos , Cromatografia de Fase Reversa , Eletroforese Capilar/métodos , Células HCT116 , Humanos , Espectrometria de Massas em Tandem/métodos
16.
Can J Microbiol ; 65(6): 421-428, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30694700

RESUMO

Caldibacillus debilis strains GB1 and Tf display distinct phenotypes. Caldibacillus debilis GB1 is capable of anaerobic growth and can synthesize ethanol while C. debilis Tf cannot. Comparison of the GB1 and Tf genome sequences revealed that the genomes were highly similar in gene content and showed a high level of synteny. At the genome scale, there were several large sections of DNA that appeared to be from lateral gene transfer into the GB1 genome. Tf did have unique genetic content but at a much smaller scale: 300 genes in Tf verses 857 genes in GB1 that matched at ≤90% sequence similarity. Gene complement and copy number of genes for the glycolysis, tricarboxylic acid cycle, and electron transport chain pathways were identical in both strains. While Tf is an obligate aerobe, it possesses the gene complement for an anaerobic lifestyle (ldh, ak, pta, adhE, pfl). As a species, other strains of C. debilis should be expected to have the potential for anaerobic growth. Assaying the whole cell lysate for alcohol dehydrogenase activity revealed an approximately 2-fold increase in the enzymatic activity in GB1 when compared with Tf.


Assuntos
Bacillaceae/genética , Genoma Bacteriano , Bacillaceae/classificação , Bacillaceae/fisiologia , Genômica , Glicólise , Oxirredução , Especificidade da Espécie
17.
Extremophiles ; 22(6): 965-974, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30182148

RESUMO

A metabolic, genomic and proteomic assessment of Fervidobacterium pennivorans strains was undertaken to clarify the metabolic and genetic capabilities of this Thermotogales species. The type strain Ven5 originally isolated from a hot mud spa in Italy, and a newly isolated strain (DYC) from a hot spring at Ngatamariki, New Zealand, were compared for metabolic and genomic differences. The fermentation profiles of both strains on cellobiose generated similar major end products (acetate, alanine, glutamate, H2, and CO2). The vast majority of end products produced were redox neutral, and carbon balances were in the range of 95-115%. Each strain showed distinct fermentation profiles on sugar substrates. The genome of strain DYC was sequenced and shown to have high sequence similarity and synteny with F. pennivorans Ven5 genome, suggesting they are the same species. The unique genome regions in Ven5, corresponded to genes involved in the Entner-Doudoroff pathway confirming our observation of DYC's inability to utilize gluconate. Genome analysis was able to elucidate pathways involved in production of the observed end-products with the exception of alanine and glutamate synthesis which were resolved with less clarity due to poor sequence identity and missing critical enzymes within the pathway, respectively.


Assuntos
Fermentação , Genoma Bacteriano , Bacilos Gram-Negativos Anaeróbios Retos, Helicoidais e Curvos/metabolismo , Açúcares/metabolismo , Bacilos Gram-Negativos Anaeróbios Retos, Helicoidais e Curvos/classificação , Bacilos Gram-Negativos Anaeróbios Retos, Helicoidais e Curvos/genética , Especificidade por Substrato , Termotolerância
18.
Extremophiles ; 22(2): 203-209, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29380170

RESUMO

This study characterizes a cryptic (pro)phage-related sequence within the Caldibacillus debilis GB1 genome, designated CBP1.CBP1 is a Siphoviridae-like genome highly related to GBVS1 from Geobacillus sp. 6k51. The CBP1genome is a 37,315 bp region containing 69 putative ORFs with a GC content of 42% flanked on both sides by host DNA integrated into the main bacterial chromosome (contig 16). Bioinformatic analyses identified cassettes of genes within the CBP1 genome that were similar in function, yet distinct in sequence, from genes previously identified in GBVS1. All of CBP1 genes had less than 60% amino acid sequence identity with GBVS1by tBLASTx, with the exception of the TMP repeat gene. CBP1 possessed all the necessary genes to undergo a temperate/lytic phage life cycle, including excision, replication, structural genes, DNA packaging, and cell lyses. Proteomic analysis of CBP1 revealed the expression of 5 proteins. One of the expressed proteins was a transcriptional regulator protein homologous to the bacteriophage λ repressor protein (cI) expressed in high amounts from the CBP1 region, consistent with a lysogenic phage in a repressed state. The CBP1 protein expression profile during host growth provides unique insight into thermophilic Siphoviridae-like phages in the repressed state within their host cells.


Assuntos
Bacillaceae/virologia , Genoma Viral , Prófagos/genética , Fases de Leitura Aberta , Prófagos/fisiologia , Termotolerância , Proteínas Virais/genética , Proteínas Virais/metabolismo
19.
J Proteome Res ; 16(5): 1839-1846, 2017 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-28418257

RESUMO

Methods for isobaric-tagged peptide analysis (e.g., TMT, iTRAQ), such as the synchronous precursor selection (SPS) tandem MS/MS/MS (MS3) approach, enable maintenance of reporter ion accuracy and precision by reducing the ratio compression caused by coisolated precursor ions. However, the decreased throughput of the MS3 approach necessitates careful optimization of acquisition strategies and methods to ensure maximal proteome coverage. We present a systematic analysis of acquisition parameters used to analyze isobaric-tagged peptide samples on current generation Orbitrap mass spectrometer (MS) hardware. In contrast with previously reported works, we demonstrate the limited utility of acquiring reporter ion data in the ion trap analyzer; ion trap acquisition had only a minimal increase in identification depth and reduced quantification precision. We establish that despite the significantly increased scan rate afforded through the use of higher energy collisional dissociation (HCD) in MS3-based ion trap isobaric tag analyses, the reduced quantification precision and reporter ion yields negate the potential benefits in proteome coverage. Lastly, using optimized parameter sets, we further demonstrate the limited utility of the ion trap detector versus the Orbitrap for reporter ion detection in an in-depth analysis of a complex proteome sample. Together, these data will serve as a valuable resource to researchers undertaking analysis on current generation Orbitrap instrumentation with isobaric tags.


Assuntos
Proteoma/análise , Proteômica/métodos , Espectrometria de Massas em Tandem/métodos , Linhagem Celular , Humanos , Íons , Proteômica/normas , Padrões de Referência , Coloração e Rotulagem , Espectrometria de Massas em Tandem/normas
20.
J Proteome Res ; 16(5): 1831-1838, 2017 05 05.
Artigo em Inglês | MEDLINE | ID: mdl-28418254

RESUMO

Multiplexed quantification with isobaric chemical tags (e.g., TMT, iTRAQ) provides a robust and efficient means to comparatively examine proteome dynamics between several biological states using a mass spectrometer (MS). The quantitative nature of isobaric tags necessitates strict validation of the observed ion signals in the chosen MS detector before differential patterns are extracted between biological states. We present an in-depth analysis of isobaric tag data acquired on current generation Orbitrap MS hardware to illustrate pitfalls in acquisition settings that can negatively impact results. We establish, for the first time, the presence of a notch, a region of no observed values, in the reporter ion distributions from isobaric-labeled peptide mixtures acquired on these instruments. We determine that this notch is present in published data across a wide range of instruments of the same or different type and is isolated to the Orbitrap mass analyzer. We demonstrate that the impact of the notch can be minimized using manipulations of Orbitrap scan parameters and on-column injection amounts. Lastly, using a mixture of synthetic standard peptides we investigated the impact on identification rates and quantification precision. Together, these data highlight an important phenomenon that negatively impacts peptide identification and quantification in the Orbitrap analyzer as well as outlining guidelines to follow to ensure minimization of MS-induced artifacts in isobaric tag experiments resulting from the notch.


Assuntos
Espectrometria de Massas/métodos , Proteoma/análise , Proteômica/métodos , Íons , Espectrometria de Massas/instrumentação , Peptídeos/análise , Peptídeos/normas , Proteoma/normas , Proteômica/normas , Coloração e Rotulagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA