Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Proteome Res ; 9(11): 5620-8, 2010 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-20815409

RESUMO

Hairdressers are frequently exposed to bleaching powder containing persulfates, a group of compounds that may induce hypersensitivity in the airways. The mechanism causing this reaction is not clear. The aim of this study was to identify changes in the nasal lavage fluid proteome after challenge with potassium persulfate in hairdressers with bleaching powder-associated rhinitis. Furthermore, we aimed to compare their response to that of hairdressers without nasal symptoms, and atopic subjects with pollen-associated nasal symptoms. To study the pathogenesis of persulfate-associated rhinitis, the response in protein expression from the upper airway was assessed by time-dependent proteomic expression analysis of nasal lavage fluids. Samples were prepared by pooling nasal lavage fluids from the groups at different time points after challenge. Samples were depleted of high-abundant proteins, labeled with iTRAQ and analyzed by online 2D-nanoLC-MS/MS. Differences in the protein pattern between the three groups were observed. Most proteins with differentially expressed levels were involved in pathways of lipid transportation and antimicrobial activities. The major finding was increased abundance of apolipoprotein A-1, 20 min postchallenge, detected solely in the group of symptomatic hairdressers. Our results suggest there may be differences between the mechanisms responsible for the rhinitis in the symptomatic and atopic group.


Assuntos
Descolorantes de Cabelo/efeitos adversos , Líquido da Lavagem Nasal/química , Exposição Ocupacional/efeitos adversos , Compostos de Potássio/imunologia , Proteínas/análise , Proteoma/imunologia , Rinite/induzido quimicamente , Sulfatos/imunologia , Apolipoproteína A-I/biossíntese , Feminino , Expressão Gênica/imunologia , Humanos , Cinética , Proteoma/análise
2.
Int Arch Occup Environ Health ; 82(10): 1261-6, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19333615

RESUMO

OBJECTIVES: Many hairdressers experience work-related symptoms from the airways caused by bleaching powder. This contains persulphates, which could be irritating to the mucous membrane and also may evoke an allergic reaction. However, specific IgE antibodies are difficult to detect. We found earlier that hairdressers with work-related bleaching powder-associated nasal symptoms reacted to persulphate, but that atopics also did and that the mechanism appeared to be similar in the two groups. In this study, we analysed gene expression of cytokines in the nose in order to further investigate the mechanism for work-related bleaching powder-associated nasal symptoms. METHODS: The study subjects belonged to either hairdressers with work-related bleaching powder-associated nasal symptoms (S; n = 6), hairdressers without work-related bleaching powder-associated symptoms (WS; n = 7) or atopics (A; n = 6). Nasal lavage was performed before and during (up to 4 h after the last challenge) provocation with potassium persulphate. Expression of two genes involved in allergic inflammation [interleukin 5 (IL5) and IL13] and one involved in cell-mediated immunity (interferon-gamma; IFNG) were analysed in nasal lavage with quantitative PCR. RESULTS: The change of IL5 in the S group differed when compared to the WS group (P = 0.0051), in the A group when compared to the WS group (P = 0.014), but not in the S group when compared to the A group (P = 0.82). The change of IL13 in the A group differed when compared to the S (P = 0.041) and WS (P = 0.014) groups, but no difference was noticed between the S and WS groups (P = 0.30). The relative level of IFNG increased from before challenge to during challenge in the S group (P = 0.031). CONCLUSIONS: Symptomatic hairdressers showed increased expression of IL5 and IFNG, but not IL13, during challenge. Hairdressers without work-related bleaching powder-associated nasal symptoms showed no markedly changed reaction. Atopics showed increased expression of IL5 and IL13. Thus, this may indicate a difference in the mechanism of symptoms between symptomatic hairdressers and atopics. However, due to the low number of participants, further studies are needed to elucidate the mechanism for persulphate-associated nasal symptoms.


Assuntos
Indústria da Beleza , Citocinas/biossíntese , Líquido da Lavagem Nasal/imunologia , Exposição Ocupacional/efeitos adversos , Compostos de Potássio/toxicidade , Hipersensibilidade Respiratória/induzido quimicamente , Sulfatos/toxicidade , Adulto , Citocinas/genética , Poeira , Feminino , Expressão Gênica , Humanos , Hipersensibilidade Imediata/induzido quimicamente , Hipersensibilidade Imediata/imunologia , Hipersensibilidade Imediata/metabolismo , Interferon gama/biossíntese , Interferon gama/genética , Interleucina-13/biossíntese , Interleucina-13/genética , Interleucina-5/biossíntese , Interleucina-5/genética , Pessoa de Meia-Idade , Líquido da Lavagem Nasal/química , Fatores de Tempo
3.
Occup Environ Med ; 64(3): 191-5, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17053020

RESUMO

OBJECTIVE: To estimate the occurrence of hand eczema in hairdressers in Sweden. METHODS: The occurrence of hand eczema was estimated in a Swedish longitudinal retrospective cohort study including all female graduates from vocational schools for hairdressers from 1970 to 1995. A stratified sample from the general population acted as controls. A self-administered questionnaire including questions on the occurrence of hand eczema, skin atopy, working periods and number of hair treatments performed per week was sent to the participants. Incidence rate ratios (IRRs) of hand eczema were estimated. RESULTS: The incidence rate of hand eczema in hairdressers was 23.8 cases/1000 person-years, whereas in hairdressers who were aged <25 years it was 37.1/1000 person-years. The corresponding IRR for hairdressers compared with controls was 2.5 (95% confidence interval (CI) 2.2 to 2.8), and that for younger hairdressers was 3.1 (95% CI 2.6 to 3.5). The mean age at onset of hand eczema was 21.6 years for hairdressers and 21.2 years for controls. The 1-year prevalence of hand eczema was 18.0% for hairdressers and 12.1% for controls. A large number of hair treatments involving exposure to skin irritants and sensitisers were reported. The incidence rate of hand eczema was higher among individuals with a history of childhood eczema, both for hairdressers and for controls, giving an (age-adjusted) IRR of 1.9 and 2.2, respectively. The attributable fraction of hand eczema from skin atopy was 9.6%. A synergistic effect of skin atopy and hairdressing was found on the occurrence of hand eczema. The relative excess risk due to interaction was 1.21 (95% CI 0.21 to 2.21; p = 0.01). CONCLUSION: Hairdressers are highly exposed to skin-damaging substances. The self-reported incidence of hand eczema was substantially higher in female hairdressers than in controls from the general population and than that found previously in register-based studies. For many individuals, onset of hand eczema occurs early in life. Only about 10% of the hand eczema cases among hairdressers would be prevented if no one with skin atopy entered the trade.


Assuntos
Indústria da Beleza/estatística & dados numéricos , Eczema/epidemiologia , Doenças Profissionais/epidemiologia , Exposição Ocupacional/efeitos adversos , Adulto , Eczema/etiologia , Feminino , Mãos , Humanos , Estudos Longitudinais , Pessoa de Meia-Idade , Doenças Profissionais/etiologia , Estudos Retrospectivos , Suécia
4.
J Occup Health ; 58(5): 470-476, 2016 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-27488042

RESUMO

OBJECTIVE: Hairdressers have an increased risk for airway symptoms especially when using hair-bleaching powder containing persulfate. To minimize exposure, dust-free bleaching powder (DFP) has been made available. We studied the effects of regular powder (RP) or DFP on the airway symptoms of hairdressers with hair-bleaching associated rhinitis. METHODS: Twelve hairdressers each performed three hair-bleachings on a wig in an exposure chamber. Half of the subjects used RP and half used DFP. Exposure to persulfate and ammonia was measured. Before and after each bleaching, the participants stated their degree of airway symptoms on a visual analogue scale. Nasal lavage and blood were sampled before exposure, after the last bleaching, and in the morning after exposure to measure inflammatory markers. RESULTS: Exposure to persulfate was higher when using RP compared to DFP, 22 (11-55) vs. 12 (8-13) µg/m3; median (min-max). Exposure to ammonia did not differ between the groups. Both groups reported an increase in asthma-like symptoms and this increase was significant. Neutrophils, lymphocytes, and monocytes increased after exposure in both groups; monocytes decreased the day after. In nasal lavage, IL-8 was increased the morning after for both types of powder, and the increase was significant in the total group. IL-6 increased immediately after exposure and the day after only in the group using RP. CONCLUSIONS: Although DFP powder emits lower levels of persulfate, effects are still elicited in symptomatic hairdressers.


Assuntos
Amônia/efeitos adversos , Asma/induzido quimicamente , Dimaprit/análogos & derivados , Descolorantes de Cabelo/efeitos adversos , Exposição Ocupacional/efeitos adversos , Rinite/induzido quimicamente , Indústria da Beleza , Biomarcadores/sangue , Dimaprit/efeitos adversos , Poeira , Humanos , Mucosa Nasal/imunologia , Doenças Profissionais/induzido quimicamente , Espirometria , Escala Visual Analógica
5.
J Allergy (Cairo) ; 2014: 681934, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24803940

RESUMO

Background. Allergy nurses are exposed to allergens and respiratory irritants, and there are no national guidelines addressing personnel safety when working with these agents. Objective. To investigate the prevalence of allergies, asthma, and hypersensitivity symptoms among allergy nurses and the use of protective equipment and measures when working with allergen concentrates and respiratory irritants. Methods. A questionnaire survey was performed among the members of the Swedish Association of Allergy Nurses. Results. Diagnosed asthma was reported by 17%, while 18% had allergy to pets, 28% had allergy to pollens, and 26% reported nasal symptoms. Fifty-one percent reported a history of asthma, allergic diseases, or hypersensitivity symptoms in their family. Exhaust ventilation was used by 24% during skin prick tests, 17% during allergen specific immunotherapy, and 33% when performing methacholine challenge tests. Tightly closed containers for disposable waste were used by 58% during skin prick tests, by 60% during immunotherapy, and by 40% during Pc provocation tests. Conclusion. Allergy nurses had a tendency to increased prevalence of lower respiratory symptoms, asthma, and allergic rhinitis and more than half of the nurses had a family history of asthma, allergic diseases, or hypersensitivity symptoms. Additional studies are needed to evaluate the validity of these results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA