Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
BMC Med Imaging ; 21(1): 65, 2021 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-33827475

RESUMO

BACKGROUND: Primary sclerosing cholangitis (PSC) is a chronic cholestatic liver disease, characterized by bile duct inflammation and destruction, leading to biliary fibrosis and cirrhosis. The purpose of this study was to investigate the utility of T1 and T2 mapping parameters, including extracellular volume fraction (ECV) for non-invasive assessment of fibrosis severity in patients with PSC. METHODS: In this prospective study, patients with PSC diagnosis were consecutively enrolled from January 2019 to July 2020 and underwent liver MRI. Besides morphological sequences, MR elastography (MRE), and T1 and T2 mapping were performed. ECV was calculated from T1 relaxation times. The presence of significant fibrosis (≥ F2) was defined as MRE-derived liver stiffness ≥ 3.66 kPa and used as the reference standard, against which the diagnostic performance of MRI mapping parameters was tested. Student t test, ROC analysis and Pearson correlation were used for statistical analysis. RESULTS: 32 patients with PSC (age range 19-77 years) were analyzed. Both, hepatic native T1 (r = 0.66; P < 0.001) and ECV (r = 0.69; P < 0.001) correlated with MRE-derived liver stiffness. To diagnose significant fibrosis (≥ F2), ECV revealed a sensitivity of 84.2% (95% confidence interval (CI) 62.4-94.5%) and a specificity of 84.6% (CI 57.8-95.7%); hepatic native T1 revealed a sensitivity of 52.6% (CI 31.7-72.7%) and a specificity of 100.0% (CI 77.2-100.0%). Hepatic ECV (area under the curve (AUC) 0.858) and native T1 (AUC 0.711) had an equal or higher diagnostic performance for the assessment of significant fibrosis compared to serologic fibrosis scores (APRI (AUC 0.787), FIB-4 (AUC 0.588), AAR (0.570)). CONCLUSIONS: Hepatic T1 and ECV can diagnose significant fibrosis in patients with PSC. Quantitative mapping has the potential to be a new non-invasive biomarker for liver fibrosis assessment and quantification in PSC patients.


Assuntos
Colangite Esclerosante/complicações , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Técnicas de Imagem por Elasticidade/métodos , Feminino , Humanos , Cirrose Hepática/complicações , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade , Adulto Jovem
2.
Radiology ; 286(2): 486-498, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28892458

RESUMO

Purpose To determine the linearity, bias, and precision of hepatic proton density fat fraction (PDFF) measurements by using magnetic resonance (MR) imaging across different field strengths, imager manufacturers, and reconstruction methods. Materials and Methods This meta-analysis was performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A systematic literature search identified studies that evaluated the linearity and/or bias of hepatic PDFF measurements by using MR imaging (hereafter, MR imaging-PDFF) against PDFF measurements by using colocalized MR spectroscopy (hereafter, MR spectroscopy-PDFF) or the precision of MR imaging-PDFF. The quality of each study was evaluated by using the Quality Assessment of Studies of Diagnostic Accuracy 2 tool. De-identified original data sets from the selected studies were pooled. Linearity was evaluated by using linear regression between MR imaging-PDFF and MR spectroscopy-PDFF measurements. Bias, defined as the mean difference between MR imaging-PDFF and MR spectroscopy-PDFF measurements, was evaluated by using Bland-Altman analysis. Precision, defined as the agreement between repeated MR imaging-PDFF measurements, was evaluated by using a linear mixed-effects model, with field strength, imager manufacturer, reconstruction method, and region of interest as random effects. Results Twenty-three studies (1679 participants) were selected for linearity and bias analyses and 11 studies (425 participants) were selected for precision analyses. MR imaging-PDFF was linear with MR spectroscopy-PDFF (R2 = 0.96). Regression slope (0.97; P < .001) and mean Bland-Altman bias (-0.13%; 95% limits of agreement: -3.95%, 3.40%) indicated minimal underestimation by using MR imaging-PDFF. MR imaging-PDFF was precise at the region-of-interest level, with repeatability and reproducibility coefficients of 2.99% and 4.12%, respectively. Field strength, imager manufacturer, and reconstruction method each had minimal effects on reproducibility. Conclusion MR imaging-PDFF has excellent linearity, bias, and precision across different field strengths, imager manufacturers, and reconstruction methods. © RSNA, 2017 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on October 2, 2017.


Assuntos
Tecido Adiposo/patologia , Fígado/patologia , Hepatopatia Gordurosa não Alcoólica/patologia , Prótons , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/normas , Espectroscopia de Ressonância Magnética/instrumentação , Espectroscopia de Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Viés de Publicação , Sensibilidade e Especificidade , Adulto Jovem
3.
Radiology ; 288(3): 748-754, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29944086

RESUMO

Purpose To evaluate MRI T1 and T2 mapping with calculation of extracellular volume (ECV) for diagnosis and grading of liver fibrosis. Materials and Methods Different grades of fibrosis were induced in 60 male Sprague-Dawley rats by bile duct ligation (BDL) and carbon-tetrachloride (CCl4) intoxication. Portal pressure was measured invasively, whereas hepatic fibrosis was quantified by hydroxyproline content, Sirius red staining, and α smooth muscle actin staining. T1 values, T2 values, and ECV were assessed by using quantitative MRI mapping techniques. Results T1 values in animals 4 weeks after BDL were greater than in control animals (718 msec ± 74 vs 578 msec ± 33, respectively; P < .001). T2 values at 4 weeks were also greater in animals that underwent BDL than in control animals (46 msec ± 6 vs 29 msec ± 2, respectively; P < .001). Similar T1 and T2 findings were observed after CCl4 intoxication. ECV was greater in animals 4 weeks after BDL compared with control animals (31.3% ± 1.3 vs 18.2% ± 3.5, respectively; P < .001), with similar results after CCl4 intoxication. High correlations were found between ECV and hepatic hydroxyproline content (BDL: r = 0.68, P < .001; CCl4: r = 0.65, P < .001), Sirius red staining (BDL: r = 0.88, P < .001; CCl4: r = 0.82, P < .001), α smooth muscle actin staining (BDL: r = 0.70, P < .001; CCl4: r = 0.73, P < .001), and portal pressure (BDL: r = 0.54, P = .003; CCl4: r = 0.39, P = .043). Conclusion Elevation of T1 and T2 values and ECV was associated with severity of liver fibrosis and portal hypertension in an experimental animal model.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Cirrose Hepática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Animais , Modelos Animais de Doenças , Fígado/diagnóstico por imagem , Fígado/patologia , Cirrose Hepática/patologia , Masculino , Ratos , Ratos Sprague-Dawley , Índice de Gravidade de Doença
4.
Am J Med Genet A ; 173(2): 435-443, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27862890

RESUMO

Loss-of-function mutations and deletions of the SOX2 gene are known to cause uni- and bilateral anophthalmia and microphthalmia as well as related disorders such as anophthalmia-esophageal-genital syndrome. Thus, anophthalmia/microphthalmia is the primary indication for targeted, "phenotype first" analyses of SOX2. However, SOX2 mutations are also associated with a wide range of non-ocular abnormalities, such as postnatal growth retardation, structural brain anomalies, hypogenitalism, and developmental delay. The present report describes three patients without anophthalmia/microphthalmia and loss-of-function mutations or microdeletions of SOX2 who had been investigated in a "genotype first" manner due to intellectual disability/developmental delay using whole exome sequencing or chromosomal microarray analyses. This result prompted us to perform SOX2 Sanger sequencing in 192 developmental delay/intellectual disability patients without anophthalmia or microphthalmia. No additional SOX2 loss-of-function mutations were detected in this cohort, showing that SOX2 is clearly not a major cause of intellectual disability without anophthalmia/microphthalmia. In our three patients and four further, reported "genotype first" SOX2 microdeletion patients, anophthalmia/microphthalmia was present in less than half of the patients. Thus, SOX2 is another example of a gene whose clinical spectrum is broadened by the generation of "genotype first" findings using hypothesis-free, genome-wide methods. © 2016 Wiley Periodicals, Inc.


Assuntos
Estudos de Associação Genética , Deficiência Intelectual/diagnóstico , Deficiência Intelectual/genética , Fenótipo , Mutação Puntual , Fatores de Transcrição SOXB1/genética , Deleção de Sequência , Encéfalo/anormalidades , Pré-Escolar , Hibridização Genômica Comparativa , Exoma , Anormalidades do Olho/diagnóstico , Anormalidades do Olho/genética , Fácies , Feminino , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Recém-Nascido , Imageamento por Ressonância Magnética/métodos , Masculino , Polimorfismo de Nucleotídeo Único , Sistema de Registros
5.
J Exp Biol ; 220(Pt 6): 1008-1018, 2017 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-28298464

RESUMO

The aging musculoskeletal system experiences a general decline in structure and function, characterized by a reduced adaptability to environmental stress. We investigated whether the older human Achilles tendon (AT) demonstrates mechanosensitivity (via biomechanical and morphological adaptations) in response to long-term mechanical loading. Thirty-four female adults (60-75 years) were allocated to either a medium-term (14 weeks; N=21) high AT strain cyclic loading exercise intervention or a control group (N=13), with 12 participants continuing with the intervention for 1.5 years. AT biomechanical properties were assessed using ultrasonography and dynamometry. Tendon cross-sectional area (CSA) was investigated by means of magnetic resonance imaging. A 22% exercise-related increment in ankle plantarflexion joint moment, along with increased AT stiffness (598.2±141.2 versus 488.4±136.9 N mm-1 at baseline), Young's modulus (1.63±0.46 versus 1.37±0.39 GPa at baseline) and about 6% hypertrophy along the entire free AT were identified after 14 weeks of strength training, with no further improvement after 1.5 years of intervention. The aging AT appears to be capable of increasing its stiffness in response to 14 weeks of mechanical loading exercise by changing both its material and dimensional properties. Continuing exercise seems to maintain, but not cause further adaptive changes in tendons, suggesting that the adaptive time-response relationship of aging tendons subjected to mechanical loading is nonlinear.


Assuntos
Tendão do Calcâneo/fisiologia , Envelhecimento , Exercício Físico , Tendão do Calcâneo/diagnóstico por imagem , Adaptação Fisiológica , Idoso , Fenômenos Biomecânicos , Módulo de Elasticidade , Feminino , Humanos , Estudos Longitudinais , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Força Muscular , Músculo Esquelético/fisiologia
6.
Eur Radiol ; 25(11): 3207-13, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25903709

RESUMO

OBJECTIVES: Our aim was to retrospectively evaluate the occurrence of respiratory motion artefacts in patients undergoing dynamic liver magnetic resonance (MR) either with gadoxetate disodium or gadobutrol. METHODS: Two hundred and thirty liver MR studies (115 with gadobutrol, 115 with gadoxetate disodium) were analysed. Respiratory motion artefacts on dynamic 3D T1-weighted MR images (pre-contrast, arterial, venous, and late-dynamic phase) were assessed using a five-point rating scale. Severe motion was defined as a score ≥ 4. Mean motion scores were compared with the Mann-Whitney-U-test. The chi-squared-test was used for dichotomous comparisons. RESULTS: Mean motion scores for gadoxetate disodium and gadobutrol showed no relevant differences for each phase of the dynamic contrast series (pre-contrast: 1.85 ± 0.70 vs. 1.88 ± 0.57, arterial: 1.85 ± 0.81 vs. 1.87 ± 0.74, venous: 1.82 ± 0.67 vs. 1.74 ± 0.64, late-dynamic: 1.75 ± 0.62 vs. 1.79 ± 0.63; p = 0.469, 0.557, 0.382 and 0.843, respectively). Severe motion artefacts had a similar incidence using gadoxetate disodium and gadobutrol (11/460 [2.4%] vs. 7/460 [1.5%]; p = 0.341). CONCLUSIONS: Gadoxetate disodium is associated with equivalent motion scores compared to gadobutrol in dynamic liver MRI. In addition, both contrast agents demonstrated a comparable and acceptable rate of severe respiratory motion artefacts. KEY POINTS: • Gadobutrol and gadoxetate disodium showed comparable motion scores in dynamic phase imaging. • The incidence of severe motion artefacts was pronounced in arterial phase imaging. • Adverse respiratory side effects were not recorded in 115 examinations with gadoxetate disodium.


Assuntos
Artefatos , Meios de Contraste , Gadolínio DTPA , Cirrose Hepática/patologia , Hepatopatias/patologia , Compostos Organometálicos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artérias , Feminino , Humanos , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Respiração , Estudos Retrospectivos
7.
Eur Radiol ; 25(10): 2869-79, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25903702

RESUMO

OBJECTIVES: To compare systematically quantitative MRI, MR spectroscopy (MRS), and different histological methods for liver fat quantification in order to identify possible incongruities. METHODS: Fifty-nine consecutive patients with liver disorders were examined on a 3 T MRI system. Quantitative MRI was performed using a dual- and a six-echo variant of the modified Dixon (mDixon) sequence, calculating proton density fat fraction (PDFF) maps, in addition to single-voxel MRS. Histological fat quantification included estimation of the percentage of hepatocytes containing fat vesicles as well as semi-automatic quantification (qHisto) using tissue quantification software. RESULTS: In 33 of 59 patients, the hepatic fat fraction was >5% as determined by MRS (maximum 45%, mean 17%). Dual-echo mDixon yielded systematically lower PDFF values than six-echo mDixon (mean difference 1.0%; P < 0.001). Six-echo mDixon correlated excellently with MRS, qHisto, and the estimated percentage of hepatocytes containing fat vesicles (R = 0.984, 0.967, 0.941, respectively, all P < 0.001). Mean values obtained by the estimated percentage of hepatocytes containing fat were higher by a factor of 2.5 in comparison to qHisto. Six-echo mDixon and MRS showed the best agreement with values obtained by qHisto. CONCLUSIONS: Six-echo mDixon, MRS, and qHisto provide the most robust and congruent results and are therefore most appropriate for reliable quantification of liver fat. KEY POINTS: • Six-echo mDixon correlates excellently with MRS, qHisto, and the estimated percentage of fat-containing hepatocytes. • Six-echo mDixon, MRS, and qHisto provide the most robust and congruent results. • Dual-echo mDixon yields systematically lower PDFF values than six-echo mDixon. • The percentage of fat-containing hepatocytes is 2.5-fold higher than fat fraction determined by qHisto. • Performance characteristics and systematic differences of the various methods should be considered.


Assuntos
Fígado Gorduroso/patologia , Adolescente , Adulto , Idoso , Feminino , Hepatócitos/patologia , Técnicas Histológicas , Humanos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Software , Adulto Jovem
8.
J Magn Reson Imaging ; 40(4): 996-1001, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24845363

RESUMO

PURPOSE: To implement and evaluate high spatial resolution three-dimensional MR contrast-enhanced angiography (3D-CEMRA) of the thighs using a blood pool contrast agent (BPCA) using the quadrature body coil only in patients with peripheral arterial occlusive disease (PAOD) in cases receiver coils cannot be used at 1.5 Tesla (T). MATERIALS AND METHODS: Nineteen patients (mean age: 68.7 ± 11.2 years; range, 38-83 years) with known PAOD (Fontaine stages; III: 16, IV: 3) prospectively underwent 3D-CEMRA at 1.5T with a noninterpolated voxel size of 0.49 × 0.49 × 0.48 mm(3) . Digital subtraction angiography (DSA) was available for comparison in all patients. Two readers independently evaluated movement artifacts, overall image quality of 3D-CEMRA, and grade of stenosis as compared to DSA. SNR and CNR levels were quantified. RESULTS: The 3D-CEMRA was successfully completed in all patients. Patient movement artifacts that affected stenosis grading occurred in 3/38 thighs. Overall image quality was rated excellent in 15/38, good in 12/38, and diagnostic in 8/38 thighs. Stenosis grading matched with that in DSA in 35/38 thighs. High SNR and CNR were measured in all vessels. CONCLUSION: The 0.125 mm(3) spatial resolution 3D-CEMRA of the thighs with a BPCA is feasible using a quadrature body coil exclusively with excellent image quality despite long acquisition times. J. Magn. Reson. Imaging 2014;40:996-1001. © 2014 Wiley Periodicals, Inc.


Assuntos
Arteriopatias Oclusivas/fisiopatologia , Gadolínio , Aumento da Imagem/instrumentação , Angiografia por Ressonância Magnética/instrumentação , Compostos Organometálicos , Doença Arterial Periférica/fisiopatologia , Coxa da Perna/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Arteriopatias Oclusivas/patologia , Velocidade do Fluxo Sanguíneo/fisiologia , Meios de Contraste , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/patologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coxa da Perna/irrigação sanguínea , Coxa da Perna/patologia
9.
Eur Radiol ; 24(2): 267-76, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24081644

RESUMO

OBJECTIVES: To evaluate diffusion-weighted MRI with acquisition of three b-values and calculation of fractioned ADCs for response evaluation of neuroendocrine liver metastases undergoing selective internal radiotherapy (SIRT). METHODS: Ten consecutive patients with neuroendocrine liver metastases underwent MRI before and following SIRT. Diffusion-weighted imaging included acquisition of the b-values 0, 50 and 800 s/mm(2) and calculation of ADC(50,800), ADC(0,50) and ADC(0,800) maps. According to therapy response, lesions were categorised into group A [≥20% reduction of the longest diameter (LD) in comparison to baseline MRI] and group B (<20% reduction of the LD). RESULTS: Twelve out of 31 metastases were categorised as group A and 19 out of 31 metastases were categorised as group B. Pretherapeutic values of ADC(0,800) and ADC(50,800) did not differ significantly between the two groups; however, ADC(0,50) was 32% lower in group A (P = 0.049). ADC(0,800) and ADC(50,800) increased significantly after therapy in both groups, however, group differences were not statistically significant. Conversely, the increase in ADC(0,50) was about a factor of 7 larger in group A than in group B (P = 0.023). CONCLUSIONS: Our study showed that the ADC(0,50) is a promising biomarker for response assessment of neuroendocrine liver metastases following SIRT. KEY POINTS: • Diffusion-weighted MRI offers new information about neuroendocrine hepatic metastases. • Evaluation of perfusion and diffusion components requires fractioned apparent diffusion coefficients (ADCs). • Perfusion effects represented by ADC (0.50) can be observed in neuroendocrine metastases. • Pretherapeutic ADC (0.50) was significantly lower in metastases with a response ≥20%. • Such biomarkers may help evaluate liver metastases in patients undergoing therapy.


Assuntos
Braquiterapia/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias Gastrointestinais/patologia , Neoplasias Gastrointestinais/radioterapia , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/radioterapia , Tumores Neuroendócrinos/diagnóstico , Tumores Neuroendócrinos/radioterapia , Idoso , Diagnóstico Diferencial , Feminino , Seguimentos , Humanos , Neoplasias Hepáticas/secundário , Masculino , Microesferas , Pessoa de Meia-Idade , Tumores Neuroendócrinos/secundário , Estudos Retrospectivos
10.
Eur Radiol ; 24(10): 2482-90, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25030459

RESUMO

OBJECTIVES: To evaluate hepatobiliary magnetic resonance imaging (MRI) using Gd-EOB-DTPA in relation to various liver function tests in patients with liver disorders. METHODS: Fifty-one patients with liver disease underwent Gd-EOB-DTPA-enhanced liver MRI. Based on region-of-interest (ROI) analysis, liver signal intensity was calculated using the spleen as reference tissue. Liver-spleen contrast ratio (LSCR) and relative liver enhancement (RLE) were calculated. Serum levels of total bilirubin, gamma glutamyl transpeptidase (GGT), aspartate aminotransferase (AST), alanine aminotransferase (ALT), glutamate dehydrogenase (GLDH), lactate dehydrogenase (LDH), serum albumin level (AL), prothrombin time (PT), creatinine (CR) as well as international normalised ratio (INR) and model for end-stage liver disease (MELD) score were tested for correlation with LSCR and RLE. RESULTS: Pre-contrast LSCR values correlated with total bilirubin (r = -0.39; p = 0.005), GGT (r = -0.37; p = 0.009), AST (r = -0.38; p = 0.013), ALT (r = -0.29; p = 0.046), PT (r = 0.52; p < 0.001), GLDH (r = -0.55; p = 0.044), INR (r = -0.42; p = 0.003), and MELD Score (r = -0.53; p < 0.001). After administration of Gd-EOB-DTPA bilirubin (r = -0.45; p = 0.001), GGT (r = -0.40; p = 0.004), PT (r = 0.54; p < 0.001), AST (r = -0.46; p = 0.002), ALT (r = -0.31; p = 0.030), INR (r = -0.45; p = 0.001) and MELD Score (r = -0.56; p < 0.001) significantly correlated with LSCR. RLE correlated with bilirubin (r = -0.40; p = 0.004), AST (r = -0.38; p = 0.013), PT (r = 0.42; p = 0.003), GGT (r = -0.33; p = 0.020), INR (r = -0.36; p = 0.011) and MELD Score (r = -0.43; p = 0.003). CONCLUSIONS: Liver-spleen contrast ratio and relative liver enhancement using Gd-EOB-DTPA correlate with a number of routinely used biochemical liver function tests, suggesting that hepatobiliary MRI may serve as a valuable biomarker for liver function. The strongest correlation with liver enhancement was found for the MELD Score. KEY POINTS: • Relative enhancement (RLE) of Gd-EOB-DTPA is related to biochemical liver function tests. • Correlation of RLE with bilirubin, ALT, AST, GGT, INR and MELD Score is reverse. • The correlation of relative liver enhancement with prothrombin time is positive. • AST, ALT, GLDH, prothrombin time, INR and MELD Score correlate with pre-contrast liver-spleen contrast ratio. • Such biomarkers may help to evaluate liver function.


Assuntos
Biomarcadores/sangue , Gadolínio DTPA , Hepatopatias/patologia , Testes de Função Hepática/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Alanina Transaminase/sangue , Bilirrubina/sangue , Meios de Contraste , Feminino , Glutamato Desidrogenase/sangue , Humanos , L-Lactato Desidrogenase/sangue , Hepatopatias/sangue , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Albumina Sérica/metabolismo , gama-Glutamiltransferase/sangue
12.
AJR Am J Roentgenol ; 198(5): 1188-95, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22528912

RESUMO

OBJECTIVE: The purpose of this study was to investigate the prevalence of incidental deep venous thrombosis (DVT) in patients with clinically suspected peripheral arterial occlusive disease (PAOD) using contrast-enhanced MR angiography (MRA) with a blood pool contrast agent. SUBJECTS AND METHODS: Two hundred fifty-nine MRA examinations with blood pool contrast agent in 245 consecutive patients (161 men; age range, 36-92 years), yielding a total of 4102 assessable arterial and venous vessel segments, were assessed with regard to the rate of incidentally observed acute and organized DVT and arterial stenosis grades. Incidental DVT was confirmed using duplex ultrasound. Contralateral nondiseased veins served as internal controls. The relationship between PAOD stages and acute and organized DVT was investigated using chi-square tests and a Mann-Whitney U test. RESULTS: Arterial stenosis grading using MRA with blood pool contrast agent revealed less than 50% luminal stenosis in 78% of segments (3199/4102), 50% or greater stenosis in 8% of segments (317/4102), and occlusion in 14% of segments (586/4102). Incidental DVT was observed in 26 of 245 patients (11%) (acute DVT was seen in 10 patients and 26 segments; organized DVT was seen in 17 patients and 35 segments; and one patient had both acute and organized DVT). All incidentally diagnosed cases of DVT were confirmed by duplex ultrasound. Internal controls revealed no false-positive or -negative findings (26 patients and 172 segments). Incidental acute DVT was significantly more common among patients without arterial stenosis greater than 50% (p < 0.05). Otherwise, there was no significant relationship between Fontaine PAOD stages and the occurrence of acute (p = 0.688) or organized (p = 0.995) DVT. CONCLUSION: Incidental DVT was prevalent in 11% of patients with clinically suspected PAOD. MRA with blood pool contrast agent has a potential role in the simultaneous assessment of arteries and veins and can detect concomitant venous disease affecting therapeutic management.


Assuntos
Arteriopatias Oclusivas/diagnóstico , Meios de Contraste , Gadolínio , Angiografia por Ressonância Magnética/métodos , Compostos Organometálicos , Doenças Vasculares Periféricas/diagnóstico , Trombose Venosa/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/epidemiologia , Distribuição de Qui-Quadrado , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Achados Incidentais , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/diagnóstico por imagem , Doenças Vasculares Periféricas/epidemiologia , Prevalência , Estatísticas não Paramétricas , Ultrassonografia Doppler Dupla , Trombose Venosa/diagnóstico por imagem , Trombose Venosa/epidemiologia
13.
Invest Radiol ; 57(7): 470-477, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35136004

RESUMO

OBJECTIVE: Robust dynamic contrast-enhanced T1-weighted images are crucial for accurate detection and categorization of focal liver lesions in liver/abdominal magnetic resonance imaging (MRI). As optimal dynamic imaging usually requires multiple breath-holds, its inherent susceptibility to motion artifacts frequently results in degraded image quality in incompliant patients. Because free-breathing imaging may overcome this drawback, the intention of this study was to evaluate a dynamic MRI sequence acquired during free breathing using the variable density, elliptical centric golden angle radial stack-of-stars radial sampling scheme, which so far has not been implemented in 4-dimensional applications. MATERIALS AND METHODS: In a prospective pilot study, 27 patients received a routine abdominal MRI protocol including the prototype free-breathing sequence (4DFreeBreathing) for dynamic imaging. This enables more convenient and faster reconstruction through variable density, elliptical centric golden angle radial stack-of-stars without the use of additional reconstruction hardware, and even higher motion robustness through soft-gating. A standard breath-hold sequence performed subsequently served as reference standard. Of the continuous dynamic data sets, each dynamic phase was analyzed regarding image quality, motion artifacts and vessel conspicuity using 5-point Likert scales. Furthermore, correct timing of the late arterial phase was compared with the preexaminations. RESULTS: 4DFreeBreathing delivered motion-free dynamic images with high temporal resolution in each subject. Overall image quality scores were rated good or excellent for 4DFreeBreathing and the gold standard without significant differences (P = 0.34). There were significantly less motion artifacts in the 4DFreeBreathing sequence (P < 0.0001), whereas vessel conspicuity in each dynamic phase was comparable for both groups (P = 0.45, P > 0.99, P = 0.22, respectively). Correct timing of the late arterial phase could be achieved in 27 of 27 (100%) examinations using 4DFreeBreathing versus 35 of 53 (66%) preexaminations using gold standard (P < 0.001). CONCLUSION: The benefit of convenient and fast image reconstruction combined with the superiority in motion robustness and timing compared with standard breath hold sequences renders 4DFreeBreathing an attractive alternative to existing free-breathing techniques in dynamic liver MRI.


Assuntos
Meios de Contraste , Aumento da Imagem , Artefatos , Estudos de Viabilidade , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Fígado/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Projetos Piloto , Estudos Prospectivos , Respiração
14.
Radiology ; 259(2): 421-8, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21330565

RESUMO

PURPOSE: To prospectively compare T2-weighted single-shot turbo spin-echo (TSE) sequences performed with parallel and conventional radiofrequency (RF) transmission at 3.0 T for liver lesion detection, image quality, lesion conspicuity, and lesion contrast. MATERIALS AND METHODS: After written informed consent and institutional review board approval, 52 consecutive patients (32 men, 20 women; mean age, 56.6 years ± 13.7 [standard deviation]) underwent routine magnetic resonance (MR) imaging with a clinical 3.0-T unit. Two independent readers reviewed images acquired with conventional and dual-source parallel RF transmission for detection of focal liver lesions, with separate reading of a third radiologist, including all available imaging findings, clinical history, and histopathologic findings, as reference. Image quality and lesion conspicuity were rated on five- and three-point evaluation scales, respectively. Contrast ratios between focal liver lesions and adjacent liver parenchyma were calculated. Significance was determined by using nonparametric Wilcoxon signed-rank and marginal homogeneity tests. RESULTS: With the reference standard, 106 index lesions were identified in 22 patients. Detection rate significantly improved from 87% (92 of 106) to 97% (103 of 106) (reader 1) and from 85% (90 of 106) to 96% (102 of 106) (reader 2) with parallel RF transmission (reader 1, P = .0078; reader 2, P = .002). Quality of parallel RF transmission images was assigned scores significantly higher, compared with quality of conventional RF transmission images (mean for reader 1, 2.88 ± 0.73 vs 4.04 ± 0.44; mean for reader 2, 2.81 ± 0.72 vs 4.04 ± 0.39; P < .0001 for both). Lesion conspicuity scores were significantly higher on parallel RF transmission images, compared with conventional RF transmission images (mean for reader 1, 2.02 ± 0.64 vs 2.92 ± 0.27; mean for reader 2, 2.06 ± 0.67 vs 2.90 ± 0.30; P < .0001 for both). Contrast ratios were significantly higher with parallel RF transmission (P < .05). CONCLUSION: Compared with conventional RF transmission, parallel RF transmission significantly improved liver lesion detection rate, image quality, lesion conspicuity, and lesion contrast. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101429/-/DC1.


Assuntos
Hepatopatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Artefatos , Meios de Contraste , Dextranos , Feminino , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional , Fígado , Hepatopatias/patologia , Nanopartículas de Magnetita , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Estudos Prospectivos , Ondas de Rádio , Estatísticas não Paramétricas
15.
Radiology ; 257(3): 743-53, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20858848

RESUMO

PURPOSE: To prospectively and intraindividually compare single-source radiofrequency (RF) excitation and dual-source parallel RF excitation in 3.0-T magnetic resonance (MR) imaging of the spine. MATERIALS AND METHODS: Institutional review board approval and written informed patient consent were obtained. The RF power of a 3.0-T MR imaging system was distributed to two ports of the body coil of the system by using independent RF transmit channels. The maximum B(1) field strength for dual-source parallel RF excitation was maintained, as compared with single-source RF excitation. The repetition time was reduced according to the revised RF setup with dual-source parallel RF excitation while maintaining specific energy absorption limitations. Thirty patients were examined with and without dual-source parallel RF excitation. Diagnostic quality was assessed independently by two radiologists according to a four-point grading system. Image contrast ratios (CRs) were calculated between reference tissues and vertebrae for single-source RF excitation and dual-source parallel RF excitation. RESULTS: The mean acceleration achieved with dual-source parallel RF excitation was 36% (range, 18%-50%). The total imaging duration of a three-station total spinal examination was reduced by one-third by using dual-source parallel RF transmission. For all cases investigated, diagnostic image quality without significant differences between the two methods and with a good interobserver agreement was achieved (Kendall tau-b, 0.50-0.84). The observed image contrast changes were predominantly small (<0.10 in 15 of 24 CRs), though they were significantly different (P < .05). CONCLUSION: While shortening examination times by approximately one-third, the dual-source parallel RF transmission mode in MR imaging of the spine yielded diagnostic image quality comparable to that with the conventional single-source RF transmission mode.


Assuntos
Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Doenças da Coluna Vertebral/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Estudos Prospectivos , Ondas de Rádio
16.
Radiology ; 256(3): 966-75, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20720078

RESUMO

PURPOSE: To prospectively compare the image quality and homogeneity of magnetic resonance (MR) images obtained by using a dual-source parallel radiofrequency (RF) excitation body MR imaging system with parallel transmission and independent RF shimming with the image quality and homogeneity of single-source MR images obtained by using standard sequences for routine clinical use in patients at 3.0 T. MATERIALS AND METHODS: After institutional review board approval and informed patient consent were obtained, a dual-source parallel RF excitation 3.0-T MR system with independent RF shimming and parallel transmission technology was used to examine 28 patients and was compared with a standard 3.0-T MR system with single RF transmission. The RF power was distributed to the independent ports of the system body coil by using two RF transmission sources with full software control, enabling independent control of the phase and amplitude of the RF waveforms. Axial T2-weighted fast spin-echo (SE) and diffusion-weighted (DW) liver images, axial T2-weighted fast SE pelvic images, and sagittal T1- and T2-weighted fast SE spinal images were obtained by using dual- and single-source RF excitation. Two radiologists independently evaluated the images for homogeneity and image quality. Statistical significance was calculated by using the nonparametric Wilcoxon signed rank test. Interobserver agreement was determined by using Cohen kappa and Kendall tau-b tests. RESULTS: Image quality comparisons revealed significantly better results with dual-source rather than single-source RF excitation at T2-weighted liver MR imaging (P = .001, kappa = 1.00) and better results at DW liver imaging at a statistical trend level (P = .066, tau-b > 0.7). Owing to reduced local energy deposition, fewer acquisitions and shorter repetition times could be implemented with dual-source RF excitation pelvic and spinal MR imaging, with image acquisition accelerating by 18%, 33%, and 50% compared with the acquisitions with single-source RF excitation. Image quality did not differ significantly between the two MR techniques (P > .05, tau-b > 0.5). CONCLUSION: Dual-source parallel RF excitation body MR imaging enables reduced dielectric shading, improved homogeneity of the RF magnetic induction field, and accelerated imaging at 3.0 T.


Assuntos
Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Artefatos , Feminino , Humanos , Aumento da Imagem/métodos , Fígado/patologia , Masculino , Pessoa de Meia-Idade , Pelve/patologia , Estudos Prospectivos , Ondas de Rádio , Coluna Vertebral/patologia , Estatísticas não Paramétricas
17.
Front Oncol ; 10: 611, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32457834

RESUMO

Background: Mucosal melanomas including melanomas of the urogenital tract represent a rare type of melanoma characterized by low mutational burden and poor prognosis. Immune checkpoint inhibition has so far only been assessed in a limited number of mucosal melanoma patients and, in contrast to response in cutaneous melanoma, was associated with disappointing response rates. The oncolytic viral immunotherapy Talimogene laherparepvec (T-VEC) has recently been approved for treatment of locally advanced or unresectable melanoma. T-VEC combines direct oncolytic effects with local and systemic immune-mediated anti-tumor response. Our rationale to use T-VEC in this case was an expected augmentation of immunogenicity by tumor lysis to overcome primary resistance of a mucosal melanoma to immune checkpoint blockade. Objective: To report the first case of an advanced mucosal melanoma of the urethra treated with intralesional application of Talimogene laherparepvec. Case Report: A 78-years old female patient was diagnosed with an advanced mucosal melanoma of the urethra with inguinal lymph node metastases and intravaginal mucosal metastases. Shortly after surgical resection of the tumor mass, intravaginal mucosal metastases, and new nodal metastases in proximity of the left iliac vessels were diagnosed. The patient was treated with the anti-PD1 antibody pembrolizumab and obtained a stable disease lasting for 30 weeks. However, upon checkpoint inhibition the patient developed a loco-regional progressive disease featuring bleeding intravaginal metastases, while nodal metastases remained stable. We stopped treatment with pembrolizumab and administered T-VEC directly into the intravaginal mucosal metastases. After five injections T-VEC yielded a partial response with clinical regression of the injected mucosal metastases. Disease remained stable for 16 weeks under biweekly T-VEC treatment. Thereafter the patient showed disease progression in nodal metastases. T-VEC was discontinued. Immunotherapy with pembrolizumab was restarted but failed to achieve a response. Finally, targeted therapy with imatinib was induced in presence of a druggable c-KIT mutation, leading to a considerable response of all tumor sites that is still ongoing. Conclusion: T-VEC represents an effective and well-tolerated treatment option for patients with loco-regionally advanced mucosal melanoma. In combination with immunotherapy, T-VEC bears the potential of synergistic effects to overcome the specific primary resistance of mucosal melanoma to immune checkpoint blockade.

18.
Eur Radiol Exp ; 3(1): 22, 2019 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-31144201

RESUMO

BACKGROUND: To determine the utility of single-contrast-bolus hepatic extracellular volume (ECV) fraction measurement at different time points to detect and quantify hepatic fibrosis. METHODS: Different grades of liver fibrosis were induced in 23 male Sprague-Dawley rats by carbon-tetrachloride (CCl4) intoxication. In ten control rats, no fibrosis was induced. Native T1 values and ECV fraction were assessed by using quantitative magnetic resonance imaging (MRI) mapping; only one contrast bolus was applied (gadobutrol 0.1 mmol/kg). ECV values were determined 5, 15, and 25 min after injection. Hepatic fibrosis was quantified histologically by Sirius red staining. RESULTS: For the 8-week-CCl4 group, the ECV fraction values obtained 5 (23.5 ± 4.8%, mean ± standard deviation), 15 (23.6 ± 4.8%), and 25 min (23.7 ± 4.7%) after injection were constant over time (p = 0.998); constant data 5-25 min after injection were also observed for the 16-week-CCl4 group and controls. Liver ECV after 15 min significantly increased with the severity of fibrosis: 18.0 ± 3.0% (controls) versus 23.6 ± 4.8% (8-week-CCl4) versus 30.5 ± 3.3% (16-week-CCl4) (p <  0.001). ECV values after 5, 15, and 25 min significantly correlated with Sirius red staining (p <  0.001 for all parameters). CONCLUSIONS: Hepatic ECV obtained using a single-contrast-bolus technique can be measured 5, 15, and 25 min after injection, obtaining constant values over time, each of them being suitable to detect diffuse hepatic fibrosis. In clinical practice, post-contrast T1 relaxation times for liver ECV fraction determination might be obtained at only one time point.


Assuntos
Meios de Contraste , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética , Compostos Organometálicos , Animais , Meios de Contraste/administração & dosagem , Modelos Animais de Doenças , Espaço Extracelular/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Compostos Organometálicos/administração & dosagem , Ratos , Ratos Sprague-Dawley
19.
Medicine (Baltimore) ; 95(14): e3275, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27057887

RESUMO

To investigate the value of a simplified intravoxel incoherent motion (IVIM) analysis for evaluation of therapy-induced tumor changes and response of breast cancer liver metastases (mBRC) undergoing radioembolization.In 21 females (mean age 54 years, range 43-72) with mBRC tumor size changes and response evaluation criteria in solid tumors (RECIST) response to 26 primary radioembolization procedures were analyzed. Standard 1.5-T liver magnetic resonance imaging including respiratory-gated diffusion-weighted imaging (DWI) with b0 = 0 s/mm, b1 = 50 s/mm, b2 = 800 s/mm before and 6 weeks after each treatment was performed. In addition to the apparent diffusion coefficient (ADC)(0,800), the estimated diffusion coefficient D' and the perfusion fraction f' were determined using a simplified IVIM approach. For each radioembolization, the 2 largest treated metastases (if available) were analyzed. Lesions were categorized according to size changes into group A (reduction of longest diameter [LD]) and group B (LD increase) after 3 months. Radioembolization procedures were further categorized into "response" (partial response and stable disease) and "nonresponse" (progressive disease) according to RECIST after 3 months. ADC and D' are given in 10 mm/s.Forty-five metastases were analyzed. Thirty-two lesions were categorized as A; 13 as B. Before therapy, group A lesions showed significantly larger f'-values than B (P = 0.001), but ADC(0,800) and D' did not differ. After therapy, in group A lesions the ADC(0,800)- and D'-values increased and f' decreased (P < 0.0001); in contrast in group B lesions f' increased (P = 0.001). Groups could be differentiated by preinterventional f' and by changes of D' and f' between pre and postinterventional imaging (area under the curve [AUC] of 0.903, 0.747 and 1.0, respectively).Preinterventional parameters did not differ between responders and nonresponders according to RECIST. ADC(0,800)- and D'-values showed a larger increase in responders compared with nonresponders (P = 0.013 and P = 0.001, respectively). After therapy f'-values decreased significantly in responders (P = 0.001). Good to excellent prediction of long-term RECIST response was possible by therapy-induced changes in LD, D', and f' (AUC 0.903, 0.879, and 0.867, respectively).A simplified IVIM model-based analysis of early post-treatment DWI can deliver additional information on tumor size changes and long-term RECIST response after radioembolization of mBRC. The estimated perfusion fraction f' is better suited for response assessment than the conventional ADC(0,800) or D'. This can be useful to guide further treatment strategy.


Assuntos
Braquiterapia , Neoplasias da Mama/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Embolização Terapêutica , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Adulto , Idoso , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Pessoa de Meia-Idade , Estudos Retrospectivos
20.
Onco Targets Ther ; 9: 6425-6433, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27799790

RESUMO

PURPOSE: The aim of this study was to evaluate an intravoxel incoherent motion (IVIM) model-based analysis of diffusion-weighted imaging (DWI) for assessing the response of hepatocellular carcinoma (HCC) to locoregional therapy. PATIENTS AND METHODS: Respiratory-gated DWI (b=0, 50, and 800 s/mm2) was retrospectively analyzed in 25 patients who underwent magnetic resonance imaging at 1.5 T before and 6 weeks following the first cycle of transarterial chemoembolization therapy, transarterial ethanol-lipiodol embolization therapy, and transarterial radioembolization therapy. In addition to the determination of apparent diffusion coefficient, ADC(0,800), an estimation of the diffusion coefficient, D', and the perfusion fraction, f', was performed by using a simplified IVIM approach. Parameters were analyzed voxel-wise. Tumor response was assessed in a central slice by using a region of interest (ROI) covering the whole tumor. HCCs were categorized into two groups, responders and nonresponders, according to tumor size changes on first and second follow ups (if available) and changes of contrast-enhanced region on the first follow up. RESULTS: In total, 31 HCCs were analyzed: 17 lesions were assigned to responders and 14 were to nonresponders. In responders, ADC(0,800) and D' were increased after therapy by ~30% (P=0.00004) and ~42% (P=0.00001), respectively, whereas f' was decreased by ~37% (P=0.00094). No significant changes were found in nonresponders. Responders and nonresponders were better differentiated by changes in D' than by changes in ADC(0,800) (area under the curve =0.878 vs 0.819 or 0.714, respectively). CONCLUSION: In patients with HCCs undergoing embolization therapy, diffusion changes were better reflected by D' than by conventional ADC(0,800), which is influenced by counteracting perfusion changes as assessed by f'.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA