Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Circulation ; 140(3): 240-261, 2019 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-31116032

RESUMO

Identification and management of patients at high bleeding risk undergoing percutaneous coronary intervention are of major importance, but a lack of standardization in defining this population limits trial design, data interpretation, and clinical decision-making. The Academic Research Consortium for High Bleeding Risk (ARC-HBR) is a collaboration among leading research organizations, regulatory authorities, and physician-scientists from the United States, Asia, and Europe focusing on percutaneous coronary intervention-related bleeding. Two meetings of the 31-member consortium were held in Washington, DC, in April 2018 and in Paris, France, in October 2018. These meetings were organized by the Cardiovascular European Research Center on behalf of the ARC-HBR group and included representatives of the US Food and Drug Administration and the Japanese Pharmaceuticals and Medical Devices Agency, as well as observers from the pharmaceutical and medical device industries. A consensus definition of patients at high bleeding risk was developed that was based on review of the available evidence. The definition is intended to provide consistency in defining this population for clinical trials and to complement clinical decision-making and regulatory review. The proposed ARC-HBR consensus document represents the first pragmatic approach to a consistent definition of high bleeding risk in clinical trials evaluating the safety and effectiveness of devices and drug regimens for patients undergoing percutaneous coronary intervention.


Assuntos
Congressos como Assunto , Consenso , Hemorragia/diagnóstico , Hemorragia/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Congressos como Assunto/tendências , District of Columbia , Hemorragia/prevenção & controle , Humanos , Paris , Intervenção Coronária Percutânea/tendências , Medição de Risco/métodos
2.
Eur Heart J ; 40(31): 2632-2653, 2019 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-31116395

RESUMO

Identification and management of patients at high bleeding risk undergoing percutaneous coronary intervention are of major importance, but a lack of standardization in defining this population limits trial design, data interpretation, and clinical decision-making. The Academic Research Consortium for High Bleeding Risk (ARC-HBR) is a collaboration among leading research organizations, regulatory authorities, and physician-scientists from the United States, Asia, and Europe focusing on percutaneous coronary intervention-related bleeding. Two meetings of the 31-member consortium were held in Washington, DC, in April 2018 and in Paris, France, in October 2018. These meetings were organized by the Cardiovascular European Research Center on behalf of the ARC-HBR group and included representatives of the US Food and Drug Administration and the Japanese Pharmaceuticals and Medical Devices Agency, as well as observers from the pharmaceutical and medical device industries. A consensus definition of patients at high bleeding risk was developed that was based on review of the available evidence. The definition is intended to provide consistency in defining this population for clinical trials and to complement clinical decision-making and regulatory review. The proposed ARC-HBR consensus document represents the first pragmatic approach to a consistent definition of high bleeding risk in clinical trials evaluating the safety and effectiveness of devices and drug regimens for patients undergoing percutaneous coronary intervention.


Assuntos
Stents Farmacológicos/efeitos adversos , Terapia Antiplaquetária Dupla/efeitos adversos , Hemorragia/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Stents/efeitos adversos , Síndrome Coronariana Aguda/complicações , Síndrome Coronariana Aguda/epidemiologia , Síndrome Coronariana Aguda/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Anemia/complicações , Anemia/epidemiologia , Anemia/fisiopatologia , Ásia/epidemiologia , Tomada de Decisão Clínica , Ensaios Clínicos como Assunto , Consenso , Europa (Continente)/epidemiologia , Fibrose/complicações , Fragilidade/complicações , Fragilidade/epidemiologia , Fragilidade/fisiopatologia , Hemorragia/epidemiologia , Humanos , Hipertensão Portal/epidemiologia , Hipertensão Portal/fisiopatologia , Adesão à Medicação/estatística & dados numéricos , Metais , Intervenção Coronária Percutânea/instrumentação , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/epidemiologia , Insuficiência Renal Crônica/fisiopatologia , Medição de Risco , Segurança , Trombocitopenia/complicações , Trombocitopenia/epidemiologia , Trombocitopenia/fisiopatologia , Resultado do Tratamento , Estados Unidos/epidemiologia
3.
Am Heart J ; 171(1): 64-72.e1-2, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26699602

RESUMO

The MDEpiNet is a public-private partnership between the US Food and Drug Administration's Center for Devices and Radiological Health and participating partners. The PASSION program is an MDEpiNet-sponsored program that aims to demonstrate the goals of MDEpiNet by using cardiovascular medical device registries to bridge evidence gaps across the medical device total product life cycle. To this end, a PASSION Think Tank meeting took place in October 2014 in Silver Spring, MD, to facilitate discussion between stakeholders about the successes, challenges, and future novel applications of medical device registries, with particular emphasis on identifying pilot projects. Participants spanned a broad range of groups including patients, device manufacturers, regulators, physicians/academicians, professional societies, providers, and payers. The meeting focus included 4 areas of cardiovascular medicine intended to cultivate interest in 4 MDEpiNet disease-specific/device-specific working groups: coronary intervention, electrophysiology, valvular disease, and peripheral vascular disease. In addition, more general issues applying to registry-based infrastructure and analytical methodologies for assessing device benefit/risk were considered to provide context for the working groups as PASSION programs going forward. This article summarizes the discussions at the meeting and the future directions of the PASSION program.


Assuntos
Doenças Cardiovasculares/terapia , Sistema de Registros , Medição de Risco/métodos , Gestão da Segurança/métodos , Congressos como Assunto , Humanos , Relações Interprofissionais , Estados Unidos
4.
Am Heart J ; 219: 1-8, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31707323
6.
J Heart Valve Dis ; 21(1): 78-87, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22474747

RESUMO

BACKGROUND AND AIM OF THE STUDY: The American College of Cardiology/American Heart Association (ACC/AHA) guidelines recommend a three-month administration of warfarin following bioprosthetic valve replacement (BVR). However, strong evidence supporting this recommendation is lacking, making process variation likely. METHODS: In the ANSWER Registry, a total of 386 patients who had received either Epic or Biocor BVRs between May 2007 and August 2008 at 40 centers was enrolled. Patterns of discharge anticoagulation and outpatient International Normalized Ratio (INR) values were collected. Mortality, embolic, and bleeding events were assessed up to six months after BVR. RESULTS: The median patient age was 74 years (interquartile range (IQR): 67-80 years), 39% of patients were female, and 65% were classified as a high thromboembolic risk. Warfarin was prescribed in 38% of all BVR patients, and in 49% of those at high risk of thromboembolism. The median time to therapeutic INR was nine days (IQR: 1 to 18 days), and 20% of patients failed to reach therapeutic levels. Among those patients achieving a therapeutic INR, 78% and 57% respectively had at least one subtherapeutic or supratherapeutic INR during the subsequent follow up to three months. During the follow up, patients treated with warfarin had similar rates of embolic events (2.8% versus 3.1%, p = 0.884), but a substantially higher incidence of bleeding than those not treated with warfarin (12% versus 3%, p = 0.0012). Among patients who were anticoagulated, those with supratherapeutic INR-values had a seven-fold higher risk for overt bleeding events (26% versus 3%). CONCLUSION: Anticoagulation strategies after BVR are highly variable. In this population, challenges in achieving and maintaining therapeutic warfarin anticoagulation are common, and are associated with an increased risk of bleeding. Further studies are required to clarify the optimal post-BVR anticoagulation strategy.


Assuntos
Bioprótese/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Hemorragia , Complicações Pós-Operatórias , Tromboembolia , Varfarina , Idoso , Idoso de 80 Anos ou mais , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Coagulação Sanguínea/efeitos dos fármacos , Monitoramento de Medicamentos/métodos , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Hemorragia/etiologia , Hemorragia/prevenção & controle , Humanos , Coeficiente Internacional Normatizado/normas , Masculino , Mortalidade , Cuidados Pós-Operatórios/efeitos adversos , Cuidados Pós-Operatórios/métodos , Cuidados Pós-Operatórios/normas , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/prevenção & controle , Risco Ajustado , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Fatores de Tempo , Resultado do Tratamento , Varfarina/administração & dosagem , Varfarina/efeitos adversos
8.
Ther Innov Regul Sci ; 55(1): 6-18, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32572772

RESUMO

BACKGROUND: Patient registries are organized systems that use observational methods to collect uniform data on specified outcomes in a population defined by a particular disease, condition, or exposure. Data collected in registries often coincide with data that could support clinical trials. Integrating clinical trials within registries to create registry-embedded clinical trials offers opportunities to reduce duplicative data collection, identify and recruit patients more efficiently, decrease time to database lock, accelerate time to regulatory decision-making, and reduce clinical trial costs. This article describes a project of the Clinical Trials Transformation Initiative (CTTI) intended to help clinical trials researchers determine when a registry could potentially serve as the platform for the conduct of a clinical trial. METHODS: Through a review of registry-embedded clinical trials and commentaries, semi-structured interviews with experts, and a multi-stakeholder expert meeting, the project team addressed how to identify and describe essential registry characteristics, practices, and processes required to for conducting embedded clinical trials intended for regulatory submissions in the United States. RESULTS: Recommendations, suggested practices, and decision trees that facilitate the assessment of whether a registry is suitable for embedding clinical trials were developed, as well as considerations for the design of new registries. Essential registry characteristics include relevancy, robustness, reliability, and assurance of patient protections. CONCLUSIONS: The project identifies a clear role for registries in creating a sustainable and reusable infrastructure to conduct clinical trials. Adoption of these recommendations will facilitate the ability to perform high-quality and efficient prospective registry-based clinical trials.


Assuntos
Sistema de Registros , Coleta de Dados , Humanos , Reprodutibilidade dos Testes , Estados Unidos
9.
J Thorac Cardiovasc Surg ; 159(1): 62-69, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30929987

RESUMO

BACKGROUND: Both biological and mechanical prosthetic valves are treatment choices for aortic valve replacement. We aimed to characterize the selection of prosthetic aortic valves among elderly Medicare patients. METHODS: This was a retrospective analysis of patients aged 65 years or older who underwent aortic valve replacement alone or in combination with other procedures in the 2006-2015 Medicare databases. Patients were continuously enrolled in Medicare Part A and B. We characterized the trends and regional variation of the selection of prosthetic valves. Multivariable logistic regression was used to evaluate the determinants that influenced the selection of prosthetic valves. RESULTS: During the study period, there were 272,921 Medicare patients aged 65 years or older who underwent aortic valve replacement and met the inclusion and exclusion criteria. The selection of mechanical aortic valves decreased from 32.0% in 2006 to 24.3% in 2015 (P < .01). In comparison with 18.5% from northeastern states, 34.6% of patients from southern states selected mechanical valves (P < .01). Major determinants of the selection of prosthetic valves include age, gender, region, hospital characteristics, and physician experience. Patients being older, male, living in the northeast region, operated on in a high-volume hospital, and by more experienced physicians were more likely to receive biological valves. CONCLUSIONS: A 24.1% decrease in the selection of mechanical aortic valves was observed among elderly Medicare patients from 2006 to 2015. A dramatic regional difference was observed in the choice of prosthetic valves across the nation.

10.
JAMA Cardiol ; 3(11): 1070-1078, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30383143

RESUMO

Importance: The Centers for Medicare & Medicaid Services national coverage determination for transcatheter aortic valve replacement (TAVR) includes volume requirements for surgical aortic valve replacement (SAVR) for hospitals seeking to initiate or continue TAVR programs. Evidence regarding the association between SAVR volume and TAVR outcomes is limited. Objective: To examine the association of hospital SAVR and combined SAVR and TAVR volumes with patient outcomes of TAVR procedures performed within 1 year, 2 years, and for the entire period after initiation of TAVR programs. Design, Setting, and Participants: This observational cohort study included 60 538 TAVR procedures performed in 438 hospitals between October 1, 2011, and December 31, 2015, among Medicare beneficiaries. Main Outcomes and Measures: The associations between SAVR volume, SAVR and TAVR volumes, and risks of death, death or stroke, and readmissions within 30 days were determined using a hierarchical logistic regression model adjusting for patient and hospital characteristics. The association between SAVR and SAVR and TAVR volumes and 1-year and 2-year mortality after TAVR procedures was determined using a multivariable proportional hazard model with a robust variance estimator. The associations for procedures performed within 1 year, 2 years, and for the entire period after initiation of TAVR programs were examined. Results: Among the 60 538 patients, 29 173 were women and 31 365 were men, with a mean (SD) age of 82.3 (8.0) years. Hospitals with high SAVR volume (mean annual volume, ≥97 per year) were more likely to adopt TAVR early and had a higher growth in TAVR volumes over time (median TAVR volume by hospitals with high SAVR volume and low SAVR volume: year 1, 32 vs 19; year 2, 48 vs 28; year 3, 82 vs 38; year 4, 118 vs 54; P < .001). In adjusted analysis, high hospital SAVR volume alone was not associated with better patient outcomes after TAVR. When hospital TAVR and SAVR volumes were jointly analyzed, patients treated in hospitals with high TAVR volume had lower 30-day mortality after TAVR (high TAVR and low SAVR vs low TAVR and low SAVR: odds ratio, 0.85; 95% CI, 0.72-0.99; high TAVR and high SAVR vs low TAVR and high SAVR: odds ratio, 0.81; 95% CI, 0.69-0.95), the effect of which was more pronounced when hospitals also had high SAVR volume. Patients treated in hospitals with high SAVR volume and high TAVR volume had the lowest 30-day mortality (vs hospitals with low SAVR volume and TAVR volume: odds ratio, 0.77; 95% CI, 0.66-0.89). Conclusions and Relevance: Hospitals with high SAVR volume are most likely to be fast adopters of TAVR. Hospital SAVR volume alone is not associated with better TAVR outcomes. Accumulating high volumes of TAVR is associated with lower mortality after TAVR, particularly when hospitals have high SAVR volumes. Hospitals with high caseloads of both SAVR and TAVR are likely to achieve the best outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Hospitais com Alto Volume de Atendimentos , Humanos , Modelos Logísticos , Masculino , Medicaid , Medicare , Análise de Sobrevida , Resultado do Tratamento , Estados Unidos
11.
Cardiol Rev ; 26(2): 73-81, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29053483

RESUMO

Transcatheter aortic valve replacement (TAVR) is a safe and effective therapy for aortic valve replacement in patients ineligible for or at high risk for surgery. However, outcomes after TAVR based on an individual's sex remain to be fully elucidated. We searched PUBMED and EMBASE using the keywords: "transcatheter aortic valve replacement," "transcatheter aortic valve implantation," "sex differences," "gender," "sex characteristics" and collected information on baseline features, procedural characteristics, and postprocedural outcomes in women. Inclusion/exclusion resulted in 23 publications. Women had less preexisting comorbidities than men. Most studies reported better survival in women (range of hazard ratio [95% CI] = 0.27 [0.09-0.84] to 0.91 [0.75-1.10]). At 30 days, women also had more vascular complications (6-20% vs 2-14%) and higher bleeding rates (10-44% vs 8-25%). Stroke rates were similar at 30 days (women, 1-7%; men, 1-5%). This literature review showed better survival in women than men after TAVR. However, women had more vascular complications and bleeding; stroke rates were similar. These findings may partly be explained by fewer baseline comorbidities in women. These results should be interpreted with caution as most measures only include unadjusted percentages.


Assuntos
Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Feminino , Humanos , Masculino , Fatores Sexuais , Resultado do Tratamento
12.
J Womens Health (Larchmt) ; 27(6): 808-814, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29741978

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is a less invasive alternative approach to surgery. Individual randomized clinical trials evaluating the safety and efficacy of TAVR were mostly underpowered for conducting separate analyses for women and men. We pooled data from premarket TAVR clinical trials comparing short (30 days)- and long-term (∼2 years) outcomes by sex. METHODS: Patient-level data from the TAVR arms of six clinical trials were pooled (2515 patients). Random-effects models for time-to-event outcomes (odds ratios [ORs] for 30-day outcomes and hazard ratios [HRs] for complete follow-up for mortality, ischemic stroke, kidney injury, major bleeding, myocardial infarction, and device migration) and dichotomous outcomes (ORs for reintervention, rehospitalization, and pacemaker implantation) were then fit to directly compare outcomes between women and men. RESULTS: Overall, the pattern of individual comorbidities was more severe in men. There was no difference in mortality risk at 30 days (female-to-male OR = 1.00 [0.69-1.46]); however, at follow-up completion (∼2 years post-TAVR), women had a 24% lower mortality risk than men (HR = 0.76 [95% CI: 0.65-0.89]). Women also had a 30% lower risk of kidney injury at 30 days (OR = 0.70 [0.49-0.98]), which increased to 33% over the complete follow-up period (HR = 0.67 [0.51-0.87]). Major bleeding was more common in women compared to men at both 30 days (OR = 1.44 [1.19-1.76]) and long-term follow-up (HR = 1.22 [1.04-1.43]). For dichotomous outcomes, women had a 68% lower risk for reinterventions (OR = 0.32 [0.18-0.58]). We did not observe any difference in the risk of ischemic stroke, myocardial infarction, device migration, rehospitalizations, or pacemaker implantations between sexes. CONCLUSIONS: This patient-level data meta-analysis of six premarket clinical trials found that women who received TAVR had fewer comorbidities at baseline. Acute outcomes (30 day) with respect to mortality were similar. Women were observed to have a lower risk of kidney injury, but higher risk of major bleeding compared to men receiving TAVR at 30 days. At complete follow-up, statistically significant advantages for women emerged in improved survival and lower reintervention risk. No differences in ischemic stroke, pacemaker implantation, or rehospitalization were observed. That women are healthier at baseline and develop fewer postprocedural complications than men may explain their higher survival.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter/métodos , Injúria Renal Aguda/epidemiologia , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Ensaios Clínicos como Assunto , Comorbidade , Feminino , Humanos , Masculino , Hemorragia Pós-Operatória/epidemiologia , Fatores Sexuais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
13.
JAMA Intern Med ; 174(11): 1788-95, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25221895

RESUMO

IMPORTANCE: Early mortality for patients who undergo aortic valve replacement (AVR) may differ between mechanical and biological prosthetic (hereinafter referred to as bioprosthetic) valves. Clinical trials may have difficulty addressing this issue owing to limited sample sizes and low mortality rates. OBJECTIVE: To compare early mortality after AVR between the recipients of mechanical and bioprosthetic aortic valves. DESIGN, SETTING, AND PARTICIPANTS: A retrospective analysis of patients 65 years or older in the Medicare databases who underwent AVR from July 1, 2006, through December 31, 2011. In the mixed-effects models adjusting for physician and hospital random effects, we estimated odds ratios (OR) of early mortality to compare mechanical vs bioprosthetic valves. EXPOSURES: Mechanical or bioprostheticaortic valve replacement. MAIN OUTCOMES AND MEASURES: Early mortality was measured as death on the date of surgery, death within 1 to 30 or 31 to 365 days after the date of surgery, death within 30 days after the date of hospital discharge, and operative mortality (death within 30 days after surgery or at discharge, whichever is longer). RESULTS: Of the 66 453 Medicare beneficiaries who met inclusion criteria, 19 190 (28.88%) received a mechanical valve and 47 263 (71.12%) received a bioprosthetic valve. The risk for death on the date of surgery was 60% higher for recipients of mechanical valves than recipients of bioprosthetic valves (OR, 1.61 [95% CI, 1.27-2.04; P < .001]; risk ratio [RR], 1.60). The risk difference decreased to 16% during the 30 days after the date of surgery (OR, 1.18 [95% CI, 1.09-1.28; P < .001]; RR, 1.16). We found no differences within 31 to 365 days after the date of surgery and within the 30 days after discharge. The risk for operative mortality was 19% higher for recipients of mechanical compared with bioprosthetic valves (OR, 1.21 [95% CI, 1.13-1.30; P < .001]; RR, 1.19). The number needed to treat with mechanical valves to observe 1 additional death on the surgery date was 290; to observe 1 additional death within 30 days of surgery, 121. Consistent findings were observed in subgroup analyses of patients who underwent concurrent AVR and coronary artery bypass graft, but not in the subgroup undergoing isolated AVR. CONCLUSIONS AND RELEVANCE: In this cohort analysis of Medicare beneficiaries, use of mechanical aortic valves was associated with a higher risk for death on the date of surgery and within the 30 days after surgery compared with bioprosthetic aortic valves among patients who underwent concurrent AVR and coronary artery bypass graft but not isolated AVR.


Assuntos
Valva Aórtica/cirurgia , Bioprótese/estatística & dados numéricos , Implante de Prótese de Valva Cardíaca/mortalidade , Próteses Valvulares Cardíacas/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Medicare , Estudos Retrospectivos , Estados Unidos
16.
Ann Thorac Surg ; 80(5): 1706-11, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16242443

RESUMO

BACKGROUND: Functional ischemic mitral regurgitation (MR) frequently arises after myocardial infarction; it is characterized by annular enlargement or lateral displacement of the subvalvular apparatus. Coapsys is a ventricular-annular remodeling device designed to treat functional ischemic MR; it does not require cardiopulmonary bypass. Initial intraoperative results of the RESTOR-MV randomized clinical trial are presented. METHODS: Patients referred for coronary artery bypass grafting with preoperative MR grade of 2 or greater were studied, excluding those with structural valve abnormalities. The Coapsys device, which consists of two epicardial pads connected by a flexible cord, was surgically implanted in 19 patients. Under epicardial echocardiographic guidance, the cord was passed through the left ventricle and tightened externally to improve leaflet coaptation and stabilize the ventricular wall; tightening was conducted with color flow Doppler imaging. RESULTS: Patients were 64.5 +/- 9.2 years old with an ejection fraction of 0.383 +/- 0.089 and received 2.7 +/- 1.1 grafts. Intraoperative MR grade was 2.7 +/- 0.8 after induction and was reduced to 0.4 +/- 0.7 after implantation (p < 0.0001). Mean epicardial dimension was reduced from 8.5 +/- 1.2 to 6.4 +/- 0.9 cm (p < 0.0001). Intraoperative MR was reduced in 95% (18 of 19) of patients, and 84% (16 of 19) had MR grade 1 or less after implantation. All implants were performed without cardiopulmonary bypass or conversion to standard annuloplasty. No hemodynamic compromise or structural damage to the mitral apparatus was noted. Significant acute remodeling was noted in the left ventricular dimensions. CONCLUSIONS: In patients without structural valve disease, the Coapsys device acutely reduces functional MR. Further randomized evaluation will assess long-term stability and compare it with standard annuloplasty techniques.


Assuntos
Desenho de Equipamento/instrumentação , Período Intraoperatório , Insuficiência da Valva Mitral/cirurgia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/etiologia , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
17.
Ann Thorac Surg ; 80(3): 876-80; discussion 880, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16122447

RESUMO

BACKGROUND: The Cox Maze III operation remains the gold standard for the surgical treatment of atrial fibrillation (AF). We report our experience using a flexible argon-powered metal cryoprobe for creation of the complete Cox-Maze III lesion set in patients with AF (the CryoMaze operation). METHODS: Beginning July 2002, 38 patients underwent the CryoMaze operation. Two patients had isolated CryoMaze procedures, whereas 36 patients had the CryoMaze performed in combination with coronary, valvular, or aortic surgery. All patients had electrocardiographic follow-up. Atrial fibrillation was continuous in 79%. Mean duration of AF before operation was 48 months. RESULTS: There were no complications related to the use of cryoenergy. There was 1 hospital death (2.6%) and no late deaths. At a mean follow-up of 12 months, 35 of 37 patients (95%) were in normal sinus rhythm. One patient required pacemaker implantation 3 months after surgery, and 1 patient refused follow-up. There have been no early or late thromboembolic events. CONCLUSIONS: The CryoMaze operation reliably cures atrial fibrillation at medium term follow-up, with rates identical to those reported for the classic Cox-Maze III operation.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Criocirurgia/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Análise de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA