Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 413(4): 1017-1025, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33247338

RESUMO

Microbial resistance to currently available antibiotics poses a great threat in the global fight against infections. An important step in determining bacterial antibiotic resistance can be selective DNA sequence capture and fluorescence labeling. In this paper, we demonstrate the fabrication of simple, robust, inexpensive microfluidic devices for DNA capture and fluorescence detection of a model antibiotic resistance gene sequence. We laser micromachined polymethyl methacrylate microchannels and enclosed them using pressure-sensitive adhesive tapes. We then formed porous polymer monoliths with DNA capture probes in these microchannels and used them for sequence-specific capture, fluorescent labeling, and laser-induced fluorescence detection of picomolar (pM) concentrations of synthetic and plasmid antibiotic resistance gene targets. The relative fluorescence for the elution peaks increased with loaded target DNA concentration. We observed higher fluorescence signal and percent recovery for synthetic target DNA compared to plasmid DNA at the same loaded target concentration. A non-target gene was used for control experiments and produced < 3% capture relative to the same concentration of target. The full analysis process including device fabrication was completed in less than 90 min with a limit of detection of 30 pM. The simplicity of device fabrication and good DNA capture selectivity demonstrated herein have potential for application with processes for bacterial plasmid DNA extraction and single-particle counting to facilitate determination of antibiotic susceptibility. Graphical abstract.


Assuntos
Escherichia coli/genética , Genes Bacterianos , Dispositivos Lab-On-A-Chip , Plasmídeos/genética , Sondas de DNA/genética , Desenho de Equipamento , Infecções por Escherichia coli/microbiologia , Fluorescência , Humanos , Hibridização de Ácido Nucleico/métodos , Porosidade , Pressão , Sepse/microbiologia
2.
Talanta Open ; 32021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34950926

RESUMO

Emerging antimicrobial drug resistance is increasing the complexity involved in treating critical conditions such as bacterial induced sepsis. Methods for diagnosing specific drug resistance tend to be rapid or sensitive, but not both. Detection methods like sequence-specific single-molecule analysis could address this concern if they could be adapted to work on smaller targets similar to those produced in traditional clinical situations. In this work we demonstrate that a 120 bp double stranded polynucleotide with an overhanging single stranded 25 bp probe sequence can be created by immobilizing DNA with a biotin/streptavidin magnetic bead system, labeling with SYBR Gold, and rinsing the excess away while the probe retains multiple fluorophores. These probes with multiple fluorophores can then be used to label a bacterial plasmid target in a sequence-specific manner. These probes enabled the detection of 1 pM plasmid samples containing a portion of an antibiotic resistance gene sequence. This system shows the possibility of improving capture and fluorescence labeling of small nucleic acid fragments, generating lower limits of detection for clinically relevant samples while maintaining rapid processing times.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA