RESUMO
This report describes a hybrid intervention addressing left circumflex artery occlusion during minimally invasive mitral valve repair. By using a radiopaque Cor-Knot device (LSI Solutions), targeted removal of occluding sutures was achieved, circumventing sternotomy and coronary artery bypass. Real-time coronary angiography provided assessment of procedural success during surgical revision in a hybrid operating room.
Assuntos
Oclusão Coronária , Procedimentos Cirúrgicos Minimamente Invasivos , Insuficiência da Valva Mitral , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Oclusão Coronária/cirurgia , Oclusão Coronária/etiologia , Oclusão Coronária/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Masculino , Angiografia Coronária , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Feminino , Complicações Pós-Operatórias/etiologia , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/efeitos adversosRESUMO
OBJECTIVES: Aortic valve regurgitation (AR) frequently complicates the clinical course after left ventricular assist device (LVAD) implantation. Transcatheter aortic valve implantation (TAVI) has emerged as an alternative to surgical aortic valve replacement (SAVR) in this cohort with a mostly high surgical risk profile. The unique challenges in LVAD patients, such as presence of non-calcified aortic valves and annular dilatation, raise concerns about device migration and paravalvular leakage (PVL) leading to missing device success. This study evaluates procedural outcomes and survival rates in LVAD patients who underwent TAVI, emphasizing strategies to enhance device success. METHODS: Between January 2017 and April 2023, 27 LVAD patients with clinically significant AR underwent elective or urgent TAVI at our centre. Primary end-points were procedural success rates, without the need for a second transcatheter heart valve (THV) and postprocedural AR/PVL. Secondary outcomes included survival rates and adverse events. RESULTS: Among the cohort, 14.8% received AR-dedicated TAVI devices, with none requiring a second THV. There was no intraprocedural AR, and 1 patient (25%) had AR > 'trace' at discharge. Additionally, 25.9% underwent device landing zone (DLZ) pre-stenting with a standard TAVI device, all without needing a second THV. There was no intraprocedural AR, and none to trace AR at discharge. Among the 59.3% receiving standard TAVI devices, 37.5% required a second THV. In this subgroup, intraprocedural AR > 'trace' occurred in 12.5%, decreasing to 6.25% at discharge. In-hospital mortality was 3.7%, and median follow-up survival was 388 days (interquartile range 208-1167 days). CONCLUSIONS: TAVI yields promising procedural outcomes and early survival rates in LVAD patients with AR. Tailored TAVI devices and pre-stenting techniques enhance procedural success. Continued research into these strategies is essential to optimize outcomes in this complex patient cohort.
Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Coração Auxiliar , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Coração Auxiliar/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodosRESUMO
Background: Myocardial efficiency should be maintained stable under light-to-moderate stress conditions, but ischemia puts the myocardium at risk for impaired functionality. Additionally, the measurement of such efficiency typically requires invasive heart catheterization and exposure to ionizing radiation. In this work, we aimed to non-invasively assess myocardial power and the resulting efficiency during pharmacological stress testing and ischemia induction. Methods: In a cohort of n = 10 healthy Landrace pigs, dobutamine stress testing was performed, followed by verapamil-induced ischemia alongside cardiac magnetic resonance (CMR) imaging. External myocardial power, internal myocardial power, and myocardial efficiency were assessed non-invasively using geometrical and functional parameters from CMR volumetric as well as blood flow and pressure measurements. Results: External myocardial power significantly increased under dobutamine stress [2.3 (1.6-3.1) W/m2 vs. 1.3 (1.1-1.6) W/m2, p = 0.005] and significantly decreased under verapamil-induced ischemia [0.8 (0.5-0.9) W/m2, p = 0.005]. Internal myocardial power [baseline: 5.9 (4.6-8.5) W/m2] was not affected by dobutamine [7.5 (6.9-9.0) W/m2, p = 0.241] nor verapamil [5.8 (4.7-8.8) W/m2, p = 0.878]. Myocardial efficiency did not change from baseline to dobutamine [21% (15-27) vs. 31% (20-44), p = 0.059] but decreased significantly during verapamil-induced ischemia [10% (8-13), p = 0.005]. Conclusion: In healthy Landrace pigs, dobutamine stress increased external myocardial power, whereas myocardial efficiency was maintained stable. On the contrary, verapamil-induced ischemia substantially decreased external myocardial power and myocardial efficiency. Non-invasive CMR was able to quantify these efficiency losses and might be useful for future clinical studies evaluating the effects of therapeutic interventions on myocardial energetics.
RESUMO
OBJECTIVES: Complex blood flow profiles in the aorta are known to contribute to vessel dilatation. We studied flow profiles in the aorta in patients with aortic valve disease before and after surgical aortic valve replacement (AVR). METHODS: Thirty-four patients with aortic valve disease underwent 4-dimensional velocity-encoded magnetic resonance imaging before and after AVR (biological valve = 27, mechanical valve = 7). Seven healthy volunteers served as controls. Eccentricity (ES) and complex flow scores (CFS) were determined from the degree of helicity, vorticity and eccentricity of flow profiles in the aorta. Model-based therapy planning was used in 4 cases to improve in silico postoperative flow profiles by personalized adjustment of size, rotation and angulation of the valve as well as aorta diameter. RESULTS: Patients with aortic valve disease showed more complex flow than controls [median ES 2.5 (interquartile range (IQR) 2.3-2.7) vs 1.0 (IQR 1.0-1.0), P < 0.001, median CFS 4.7 (IQR 4.3-4.8) vs 1.0 (IQR 1.0-2.0), P < 0.001]. After surgery, flow complexity in the total patient cohort was reduced, but remained significantly higher compared to controls [median ES 2.3 (IQR 1.9-2.3) vs 1.0 (IQR 1.0-1.0), P < 0.001, median CFS 3.8 (IQR 3.0-4.3) vs 1.0 (IQR 1.0-2.0), P < 0.001]. In patients after mechanical AVR, flow complexity fell substantially and showed no difference from controls [median ES 1.0 (IQR 1.0-2.3) vs 1.0 (IQR 1.0-1.0), P = 0.46, median CFS 1.0 (IQR 1.0-3.3) vs 1.0 (IQR 1.0-2.0), P = 0.71]. In all 4 selected cases (biological, n = 2; mechanical, n = 2), model-based therapy planning reduced in silico complexity of flow profiles compared to the existing post-surgical findings [median ES 1.7 (IQR 1.4-1.7) vs 2.3 (IQR 2.3-2.3); CFS 1.7 (IQR 1.4-2.5) vs 3.8 (IQR 3.3-4.3)]. CONCLUSIONS: Abnormal flow profiles in the aorta more frequently persist after surgical AVR. Model-based therapy planning might have the potential to optimize treatment for best possible individual outcome. CLINICAL TRIAL REGISTRATION NUMBER: clinicaltrials.gov NCT03172338, 1 June 2017, retrospectively registered; NCT02591940, 30 October 2015, retrospectively registered.
Assuntos
Valvopatia Aórtica , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Humanos , Projetos PilotoRESUMO
OBJECTIVE: We aimed to investigate the combined effects of arterial hypertension, bicuspid aortic valve disease (BAVD) and age on the distensibility of the ascending and descending aortas in patients with aortic coarctation. DESIGN: Cross-sectional study. SETTING: The study was conducted at two university medical centres, located in Berlin and London. PARTICIPANTS: A total of 121 patients with aortic coarctation (ages 1-71 years) underwent cardiac MRI, echocardiography and blood pressure measurements. OUTCOME MEASURES: Cross-sectional diameters of the ascending and descending aortas were assessed to compute aortic area distensibility. Findings were compared with age-specific reference values. The study complied with the Strengthening the Reporting of Observational Studies in Epidemiology statement and reporting guidelines. RESULTS: Impaired distensibility (below fifth percentile) was seen in 37% of all patients with coarctation in the ascending aorta and in 43% in the descending aorta. BAVD (43%) and arterial hypertension (72%) were present across all ages. In patients >10 years distensibility impairment of the ascending aorta was predominantly associated with BAVD (OR 3.1, 95% CI 1.33 to 7.22, p=0.009). Distensibility impairment of the descending aorta was predominantly associated with arterial hypertension (OR 2.8, 95% CI 1.08 to 7.2, p=0.033) and was most pronounced in patients with uncontrolled hypertension despite antihypertensive treatment. CONCLUSION: From early adolescence on, both arterial hypertension and BAVD have a major impact on aortic distensibility. Their specific effects differ in strength and localisation (descending vs ascending aorta). Moreover, adequate blood pressure control is associated with improved distensibility. These findings could contribute to the understanding of cardiovascular complications and the management of patients with aortic coarctation.
Assuntos
Envelhecimento/patologia , Aorta/patologia , Coartação Aórtica/patologia , Doença da Válvula Aórtica Bicúspide/patologia , Hipertensão/patologia , Adolescente , Adulto , Coartação Aórtica/epidemiologia , Doença da Válvula Aórtica Bicúspide/epidemiologia , Estudos Transversais , Ecocardiografia , Feminino , Humanos , Hipertensão/epidemiologia , Masculino , Adulto JovemRESUMO
We aimed to assess surrogate markers for left ventricular (LV) myocardial power and efficiency in patients with isolated aortic stenosis (AS) and combined stenosis/regurgitation (AS/AR). In AS (n = 59), AS/AR (n = 21) and controls (n = 14), surrogates for LV myocardial power and circulatory/external myocardial efficiency were obtained from cardiac MRI. Median surrogate LV myocardial power was increased in AS, 7.7 W/m2 (interquartile range 6.0-10.2; p = 0.010) and AS/AR, 10.8 W/m2 (8.9-13.4; p < 0.001) when compared to controls, 5.4 W/m2 (4.2-6.5), and was lower in AS than AS/AR (p < 0.001). Surrogate circulatory efficiency was decreased in AS, 8.6% (6.8-11.1; p < 0.001) and AS/AR, 5.4% (4.1-6.2; p < 0.001) when compared to controls, 11.8% (9.8-16.9). Surrogate external myocardial efficiency was higher in AS, 15.2% (11.9-18.6) than in AS/AR, 12.2% (10.1-14.2; p = 0.031) and was significantly lower compared to controls, 12.2% (10.7-18.1) in patients with reduced ejection fraction (EF), 9.8% (8.1-11.7; p = 0.025). In 16% of all cases, left ventricular mass/volume indices and EF were within normal ranges, wheras surrogate LV myocardial power was elevated and patients were symptomatic. Although influenced by pressure/volume load, the myocardium is additionally affected by remodelling processes. Surrogates for circulatory efficiency and LV myocardial power gradually reflect alterations in patients with AS and AS/AR, even when surrogate external myocardial efficiency, EF, mass and volume indices still remain compensated.
Assuntos
Valva Aórtica/patologia , Biomarcadores , Débito Cardíaco , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/fisiopatologia , Idoso , Algoritmos , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Volume Sistólico , Disfunção Ventricular EsquerdaRESUMO
AIMS: Previous studies demonstrated poor public awareness of heart failure (HF) compared with myocardial infarction and stroke. With respect to several activities to improve HF awareness in recent years, we present data on the development of HF awareness and information sources in Germany over 8 years. METHODS AND RESULTS: In 2007, 2012, and 2015, respectively, 2531, 359, and 171 respondents answered questions about causes, presentation, prognosis, and treatment of HF from a survey developed by the German Competence Network HF. Relationships between respondents' sociodemographic data and their HF knowledge were explored and changes in knowledge and use of information sources analysed. Sixty-eight per cent of respondents knew HF as 'weakness of the heart'. Seventy-nine per cent knew shortness of breath, 74% reduced exercise tolerance, and 52% knew leg edema as symptoms. Only 40% knew all three symptoms. Although up to 34% of the respondents were directly or indirectly affected by HF, they demonstrated poor knowledge about severity and prognosis. Between 2007 and 2015, overall HF awareness has not changed; awareness about treatment has dropped significantly. Younger respondents used all media, especially internet, for information about health; older respondents preferred printed/verbal media and their physician. CONCLUSIONS: We found rather insufficient public knowledge on HF etiology and symptoms but especially about management, severity, and prognosis, which is essential for good self-care and adherence of patients. Heart failure awareness has not improved even though awareness campaigns were held over the years. It seems that especially older patients should be much more approached by their family physicians.