Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(24)2022 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-36560254

RESUMO

In this study, a noncontact fabric loop sensor based on magnetic-field-induced conductivity, which can simultaneously detect cardiac activity and respiration signals, was developed and the effects of the sensor's shape and measurement position on the sensing performance were analyzed. Fifteen male subjects in their twenties wore sleeveless shirts equipped with various types of fabric loop sensors (spiky, extrusion, and spiral), and the cardiac activity and respiratory signals were measured twice at positions P2, P4, and P6. The measurements were verified by comparing them against the reference electrocardiogram (ECG) and respiratory signals measured using BIOPAC® (MP150, ECG100B, RSP100C). The waveforms of the raw signal measured by the fabric loop sensor were filtered with a bandpass filter (1-20 Hz) and qualitatively compared with the ECG signal obtained from the Ag/AgCI electrode. Notwithstanding a slight difference in performance, the three fabric sensors could simultaneously detect cardiac activity and respiration signals at all measurement positions. In addition, it was verified through statistical analysis that the highest-quality signal was obtained at the measurement position of P4 or P6 using the spiral loop sensor.


Assuntos
Têxteis , Dispositivos Eletrônicos Vestíveis , Humanos , Masculino , Respiração , Eletrodos , Condutividade Elétrica
2.
BMC Oral Health ; 22(1): 626, 2022 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-36550451

RESUMO

BACKGROUND: School children are in a developmental period in which permanent teeth replace primary dentition. It is also a period with a high incidence of gingivitis and caries, which can be improved with adequate tooth brushing. Advances in information technology have led to the development of smart health devices that assist in tooth brushing. We compared the effectiveness of computer-assisted toothbrushing using a toothbrushing instruction (TBI) method called the smart toothbrush and smart mirror (STM) system with that of conventional TBI (verbal instructions) for plaque control in school children. METHODS: This randomized controlled clinical trial analyzed and compared the reduction of the modified Quigley-Hein plaque index between the two methods in 42 school children. The participants were randomly assigned to the STM system group (n = 21) or conventional-TBI group (n = 21). The plaque indices were evaluated at baseline, immediately after TBI (day 0), and 1 week and 1 month after TBI. RESULTS: The STM system and conventional TBI led to an average reduction of 40.50% and 40.57%, respectively, in whole mouth plaque. Reductions in the plaque indices within each tested time period were observed in both groups (P < 0.001), and the mean plaque reduction did not differ between the two groups (P = 0.44). CONCLUSIONS: The present study tested a computer assisted system for TBI, more studies are needed to confirm its usefulness in different objectives. Clinical relevance The computer-assisted STM system may be an alternative of TBI for children. Trial registration ClinicalTrials.gov (NCT04627324) Registered 13/11/2020-Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT04627324 .


Assuntos
Placa Dentária , Gengivite , Humanos , Criança , Escovação Dentária , Placa Dentária/prevenção & controle , Resultado do Tratamento , Dispositivos para o Cuidado Bucal Domiciliar , Índice de Placa Dentária , Método Simples-Cego , Desenho de Equipamento
3.
J Med Syst ; 45(4): 41, 2021 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-33608815

RESUMO

Despite recent research on joint motion measurement to monitor human body movement, current measurement techniques and tools have significant limitations, including requiring large space for measurement and causing discomfort in test subjects wearing motion sensors. Our study aims, first, to develop carbon nanotube (CNT)-based textile joint motion sensors. Second, ours study aims to identify the most suitable CNT-based sensor structure and attachment method for use on a wearable platform during general exercise speeds. Lastly, we used these sensors on the human body, using sleeves and legs to find the most stable location, and we used the CNT-based sensor condition to monitor joint motions. We utilized our CNT-based sensor, which has proper elasticity as well as conductivity, and applied it to the elbow and knee joints. Based on the strain gauge principle, we monitored the variance of electric resistance that occurred when the CNT-based sensor was stretched due to limb motion. Our study tested 48 types of sensors. These sensors were applied to the CNT using different base knit textiles as well as different attachment methods, layers, sensor lengths, and sensor widths. The four most successful sensor types, which showed superior efficacy over the others in joint motion measurement, were selected for further study. These four sensors were then used to measure the elbow and knee joint motions of human subjects by placing them on different locations on sleeves and legs. The CNT knit textile sensors best suited to measuring joint motions are those with a double-layered CNT knit and 5 cm long × 0.5 cm or 1 cm wide sensors attached to a polyester¬-based knit using a welding method. The best position for the sensor to more stably monitor joint motions was the "below hinge position" from the elbow or knee hinge joint. Our study suggests an alternative strategy for joint-motion measurement that could contribute to the development of more comfortable and human-friendly methods of human limb motion measurement.


Assuntos
Vestuário , Extremidades/fisiologia , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Movimento/fisiologia , Têxteis , Humanos , Nanotubos de Carbono
4.
Clin Oral Investig ; 19(6): 1389-94, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25391495

RESUMO

OBJECTIVE: The objective of this study was to compare the efficacy of computer-assisted TBI using a smart toothbrush (ST) and smart mirror (SM) in plaque control to that of conventional TBI. MATERIALS AND METHODS: We evaluated the plaque removal efficacy of a ST comprising a computer-assisted, wirelessly linked, three-dimensional (3D) motion-capture, data-logging, and SM system in TBI. We also evaluated the efficacy of TBI with a ST and SM system by analyzing the reductions of the modified Quigley-Hein plaque index in 60 volunteers. These volunteers were separated randomly into two groups: conventional TBI (control group) and computer-assisted TBI (experimental group). The changes in the plaque indexes were recorded immediately, 1 week, 1 month, and 10 months after TBI. RESULTS: The patterns of decreases in the modified Quigley-Hein plaque indexes were similar in the two groups. Reductions of the plaque indexes of both groups in each time period were observed (P < 0.0001), and the effects of TBI did not differ between the two groups (P = 0.3803). All volunteers were sufficiently motivated in using this new system. CONCLUSION: The reported new, computer-assisted TBI system might be an alternative option in controlling dental plaque and maintaining oral hygiene. CLINICAL RELEVANCE: Individuals can be motivated by the new system; meanwhile, comparable effects of controlling dental plaque can be achieved.


Assuntos
Instrução por Computador , Placa Dentária/prevenção & controle , Imageamento Tridimensional , Escovação Dentária , Acelerometria , Adulto , Índice de Placa Dentária , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
5.
J Med Syst ; 39(12): 191, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26490149

RESUMO

This research is an extension of a previous research [1] on the different effects of sensor location that is relatively suitable for heart rate sensing. This research aimed to elucidate the causes of wide variations in heart rate measurements from the same sensor position among subjects, as observed in previous research [1], and to enhance designs of the inductive textile electrode to overcome these variations. To achieve this, this study comprised two parts: In part 1, X-ray examinations were performed to determine the cause of the wide variations noted in the findings from previous research [1], and we found that at the same sensor position, the heart activity signal differed with slight differences in the positions of the heart of each subject owing to individual differences in the anatomical heart location. In part 2, three types of dual-loop-type textile electrodes were devised to overcome variations in heart location that were confirmed in part 1 of the study. The variations with three types of sensor designs were compared with that with a single-round type of electrode design, by using computer simulation and by performing a t-test on the data obtained from the experiments. We found that the oval-oval shaped, dual-loop-type textile electrode was more suitable than the single round type for determining morphological characteristics as well as for measuring appropriate heart activity signals. Based on these results, the oval-oval, dual-loop-type was a better inductive textile electrode that more effectively overcomes individual differences in heart location during heart activity sensing based on the magnetic-induced conductivity principle.


Assuntos
Vestuário , Eletrodos , Frequência Cardíaca , Coração/anatomia & histologia , Tecnologia de Sensoriamento Remoto/instrumentação , Telemedicina/instrumentação , Simulação por Computador , Desenho de Equipamento , Humanos
6.
J Med Syst ; 38(2): 2, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24481717

RESUMO

In the research related to heart rate measurement, few studies have been done using magnetic-induced conductivity sensing methods to measure the heart rate. The aim of this study was to analyze the effect of the position of a textile-based inductive coil sensor on the measurement of the heart rate. In order to assess the capability of the textile-based inductive coil sensor and the repeatability of measured cardiac muscle contractions, we proposed a new quality index based on the morphology of measured signals using a textile-based inductive coil sensor. We initially explored eight potential positions of the inductive sensor in a pilot experiment, followed by three sensor positions in the main experiment. A simultaneously measured electrocardiography (ECG) signal (Lead II) which was used as a reference signal for a comparison of the R-peak location with signals obtained from selected positions of the textile-based inductive coil sensor. The result of the main experiment indicated that the total quality index obtained from the sensor position 'P3', which was located 3 cm away from the left side from the center front line on the chest circumference line, was the highest (QI value = 1.30) among the three positions across all the subjects. This finding led us to conclude that (1) the position of the textile-based inductive coil sensor significantly affected the quality of the measurement results, and that (2) P3 would be the most appropriate position for the textile-based inductive coil sensor for heart rate measurements based on the magnetic-induced conductivity sensing principle.


Assuntos
Eletrocardiografia Ambulatorial/instrumentação , Frequência Cardíaca/fisiologia , Magnetismo/instrumentação , Têxteis , Adulto , Desenho de Equipamento , Humanos , Masculino , Projetos Piloto , Reprodutibilidade dos Testes
7.
Psychiatry Res ; 187(3): 418-23, 2011 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-20659771

RESUMO

The purpose of this study was to investigate the central problem features of Korean patients with senile dementia and to prioritize the features according to risk to the patient with a view to the implementation of remote monitoring technologies. Twenty central problem features were extracted using factorial analysis. The frequency of violent language and confabulation, gathering, and repetition was significantly greater in female than in male patients with senile dementia. All central features, with the exception of abnormal sexual behavior and audiovisual deficits, differed in frequency between the normal elderly and the senile dementia patients and between patients with dementias of different severity. Judgment disorder was the greatest differentiating factor between the normal elderly and the patients with senile dementia. For dementia severity, memory disorder was the greatest differentiating factor of severe versus mild dementia. When risk to the patient was analyzed, problems of perception were identified as the problem features of highest priority.


Assuntos
Doença de Alzheimer/complicações , Doença de Alzheimer/diagnóstico , Monitorização Fisiológica/métodos , Atividades Cotidianas , Adaptação Psicológica , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/epidemiologia , Análise de Variância , Sintomas Comportamentais/etiologia , Diagnóstico Diferencial , Análise Fatorial , Feminino , Humanos , Coreia (Geográfico) , Idioma , Masculino , Percepção , Índice de Gravidade de Doença , Fatores Sexuais
8.
Biomed Mater Eng ; 26 Suppl 1: S1087-93, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26405865

RESUMO

The very first step to process electrocardiogram (ECG) signal is to eliminate baseline wandering interference that is usually caused by electrode-skin impedance mismatch, motion artifacts due to a patient's body moment or respiratory breathing. A new method is thus suggested to remove baseline wandering in ECG by improving the detrending method that was originally proposed for eliminating slow non-stationary trends from heart rate variability (HRV). In our proposed method, a global trend is estimated in terms of baseline wandering by merging the local trend based on an ECG segment that represents a part of the ECG signal. The experimental results show that the improved detrending method can efficiently resolve baseline wandering without distorting any morphological characteristic embedded in the ECG signal in no time delay manner.


Assuntos
Artefatos , Diagnóstico por Computador/métodos , Eletrocardiografia/métodos , Frequência Cardíaca/fisiologia , Reconhecimento Automatizado de Padrão/métodos , Processamento de Sinais Assistido por Computador , Algoritmos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
IEEE Trans Biomed Eng ; 49(7): 694-9, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12083304

RESUMO

Microwave radiometry is the spectral measurement technique of resolving electromagnetic radiation of all matters which temperature is above absolute zero. This technique utilizes the electromagnetic noise field generated by a thermal volume similar to a mechanism existing in biological tissues. One particular application of microwave radiometry is for analyzing temperature differentials of inside of human body to detect and diagnose some crucial pathological conditions. For the general evaluation of a microwave radiometer, we propose a new type of phantom containing a mammary gland tumor imitator by considering biological heat diffusion effects propagated by a real tumor. Theoretical researches of human tumor revealed the fact that temperature distribution of tissues around a tumor formed a Gaussian statistics. To comply with the physiological property of the real tumor, we built a mammary gland tumor imitator composed of two parts (pseudotumor and thermal anomaly) and observed its temperature distribution when it was placed inside a phantom. Our results showed that the thermal properties of tumor imitator well agreed with heat-transfer properties of a real tumor and the proportional linear relationship existed between the location of tumor imitator and the intensity of radiometer measurements. From this relationship, we could also estimate several parameters related with our phantom, such as the minimum detectable size and maximum detectable depth of a tumor imitator.


Assuntos
Neoplasias Mamárias Animais/diagnóstico , Imagens de Fantasmas , Radiometria/instrumentação , Radiometria/métodos , Temperatura Alta , Humanos , Neoplasias Mamárias Animais/irrigação sanguínea , Neoplasias Mamárias Animais/fisiopatologia , Micro-Ondas , Modelos Biológicos , Modelos Cardiovasculares , Sensibilidade e Especificidade , Condutividade Térmica
10.
Yonsei Med J ; 43(1): 65-72, 2002 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11854935

RESUMO

The purpose of this study was to investigate the function of the autonomic nervous system in children with spastic cerebral palsy (CP) through an analysis of heart rate variability (HRV) occurring with orthostatic stress. Twelve children with spastic CP and twelve normal children participated in this study. The echocardiogram (ECG) signals were recorded for 3 minutes in both the supine and 70 degrees C head-up tilt positions, and then the HRV signals underwent power spectrum analysis at each position. Two components were measured; a low- frequency (LF) component (0.05 - 0.15 Hz) primarily reflecting sympathetic activity during orthostatic stress and a high-frequency (HF) component (0.15 - 0.4 Hz) reflecting parasympathetic activity. In the supine position, there was no significant difference between any of the HRV components of the two groups. In the head-up tilt position, absolute and normalized LF were significantly increased and absolute HF was significantly decreased in the normal children (p < 0.05), but not in the children with spastic CP. The results of this study suggest that cardiac autonomic functions, such as vagal withdrawal and sympathetic activation which occur during head-up tilt position, are not sufficient to overcome the orthostatic stress arising in spastic CP children.


Assuntos
Sistema Nervoso Autônomo/fisiopatologia , Paralisia Cerebral/fisiopatologia , Frequência Cardíaca , Criança , Feminino , Humanos , Masculino , Postura , Decúbito Dorsal
11.
Am J Chin Med ; 31(3): 455-66, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12943176

RESUMO

This study describes a thermo-visual method to diagnose intracranial hypertension syndrome that is caused by a high intracranial pressure by observing the relative temperature distribution around the "Yin-Tang" acupuncture point. Based on thermo-visual analysis of 3000 thermal images scanned by infrared thermal imaging system acquired from 1256 admitted patients, we found that a certain specific temperature distribution around the Yin-Tang acupuncture point was related with the degree of severity of intracranial hypertension syndrome. Thus, we claim that the evaluation of the relative temperature distribution around the Yin-Tang acupuncture point can be used to diagnose and control intracranial hypertension syndrome during medical treatments.


Assuntos
Pontos de Acupuntura , Terapia por Acupuntura , Hipertensão Intracraniana/diagnóstico , Terapia por Acupuntura/métodos , Adolescente , Adulto , Criança , Pré-Escolar , Análise Diferencial Térmica/métodos , Feminino , Humanos , Hipertermia Induzida/métodos , Lactente , Hipertensão Intracraniana/fisiopatologia , Masculino , Pessoa de Meia-Idade , Fenômenos Fisiológicos da Pele , Termografia/métodos
12.
Artigo em Inglês | MEDLINE | ID: mdl-25571434

RESUMO

There are many types of devices which help to manage a personal health conditions such as heartbeat chest belt, pedometer and smart watch. And the most common device has the relationship with heart rate or ECG data. However, users have to attach some electrode or fasten the belt on the bare skin to measure bio-signal information. Therefore, most of people want more convenient and short-ready-time and no-need to attach electrode. In this paper, we proposed the high-resolution measuring system of mechanical activity of cardiac muscle and thereby measure heartbeat. The principle of the proposed measuring method is that the alternating current generate alternating magnetic field around coil. This primary magnetic field induces eddy current which makes magnetic field against primary coil in the nearby objects. To measure high-resolution changes of the induced secondary magnetic fields, we used digital Phase-locked loop(PLL) circuit which provides more high-resolution traces of frequency changes than the previous studies based on digital frequency counter method. As a result of our preliminary experiment, peak-peak intervals of the proposed method showed high correlation with R-R intervals of clinical ECG signals(r=0.9249). Also, from signal traces of the proposed method, we might make a conjecture that the contraction of atrium or ventricle is reflected by changing conductivity of cardiac muscle which is beating ceaselessly.


Assuntos
Coração/fisiologia , Monitorização Ambulatorial/instrumentação , Adulto , Eletrocardiografia , Eletrodos , Campos Eletromagnéticos , Frequência Cardíaca , Humanos , Masculino , Contração Miocárdica , Adulto Jovem
13.
Clin Interv Aging ; 9: 1709-19, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25336936

RESUMO

PURPOSE: Freezing of gait (FOG), increasing the fall risk and limiting the quality of life, is common at the advanced stage of Parkinson's disease, typically in old ages. A simple and unobtrusive FOG detection system with a small calculation load would make a fast presentation of on-demand cueing possible. The purpose of this study was to find a practical FOG detection system. PATIENTS AND METHODS: A sole-mounted sensor system was developed for an unobtrusive measurement of acceleration during gait. Twenty patients with Parkinson's disease participated in this study. A simple and fast time-domain method for the FOG detection was suggested and compared with the conventional frequency-domain method. The parameters used in the FOG detection were optimized for each patient. RESULTS: The calculation load was 1,154 times less in the time-domain method than the conventional method, and the FOG detection performance was comparable between the two domains (P=0.79) and depended on the window length (P<0.01) and dimension of sensor information (P=0.03). CONCLUSION: A minimally constraining sole-mounted sensor system was developed, and the suggested time-domain method showed comparable FOG detection performance to that of the conventional frequency-domain method. Three-dimensional sensor information and 3-4-second window length were desirable. The suggested system is expected to have more practical clinical applications.


Assuntos
Aceleração , Apraxia da Marcha/diagnóstico , Doença de Parkinson/diagnóstico , Acelerometria/instrumentação , Acidentes por Quedas , Idoso , Idoso de 80 Anos ou mais , Feminino , Apraxia da Marcha/complicações , Apraxia da Marcha/psicologia , Humanos , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/complicações , Doença de Parkinson/psicologia , Qualidade de Vida/psicologia , Fatores de Risco , Processamento de Sinais Assistido por Computador/instrumentação , Suporte de Carga
14.
IEEE Trans Biomed Eng ; 59(3): 872-81, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22203701

RESUMO

Due to the possible occurrence of periodontal disease at an early age, it is important to have proper toothbrushing habits as early as possible. With this aim, the feasibility and concept of a smart toothbrush (ST) capable of tracing toothbrushing motion and orientation information was suggested. In this study, we proposed the advanced ST system and brushing region classification algorithm. In order to trace the brushing region and the orientation of a toothbrush in the mouth, we required the absolute coordinate information of ST. By using tilt-compensated azimuth (heading) algorithm, we found the inclination and orientation information of the toothbrush, and the orientation information while brushing inner tooth surfaces showed specific heading features that could be reliably discriminated from other brushing patterns. In order to evaluate the feasibility of clinical usage of the proposed ST, 16 brushing regions were investigated by 15 individual healthy subjects. The proposed ST system demonstrated 97.1%(±0.91) of the region detection accuracy and 15 brushing regions could be classified. This study also showed that the proposed ST system may be helpful for dental care personnel in patient education and instruction for oral hygiene regarding brushing habits.


Assuntos
Magnetismo/instrumentação , Higiene Bucal , Escovação Dentária/instrumentação , Aceleração , Algoritmos , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Humanos , Masculino , Microcomputadores , Movimento (Física) , Telemetria , Adulto Jovem
15.
Geriatr Gerontol Int ; 12(2): 257-64, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21999184

RESUMO

AIM: Bradykinesia of the lower limb is an important limiting factor of the quality of life in parkinsonian patients. This study aims to develop quantitative measures of bradykinesia and to investigate the possible dissociation of amplitude and velocity measures and their dependence on movement direction during toe-tapping. METHODS: Subjects included 39 patients with PD, as well as 14 healthy control subjects. A gyrosensor on the dorsum of a foot was used to measure ankle joint movement during toe-tapping. Four representations (root-mean square, mean peak, coefficient of variation in peaks, peak in the last 5 s) for each of amplitude and velocity and for each of plantar flexion and dorsiflexion movement of toe-tapping were investigated. Outcome measures were compared between patients and controls, and their correlations with clinical scores were investigated. Category distributions of outcome measures in patients were analyzed. RESULTS: All outcome measures were smaller in patients than in controls (P < 0.001) and correlated well with clinical scores (P < 0.01). The mean peak of plantar-flexion velocity and variation of dorsiflexion velocity best represented the clinical toe-tapping score (r = 0.72-0.81). All clinical scores showed better correlation with velocity than with amplitude, and velocity was more affected (dispersed from the performance of controls) than amplitude. Movement directions had a slight effect on the results; specifically, the magnitude measures better correlated during plantar flexion and the variation measure better correlated during dorsiflexion. CONCLUSION: The suggested measures represented clinical scores well and are expected to be helpful in clinical diagnosis of lower limb bradykinesia. Possible dissociations of amplitude and speed impairments and of movement directions in PD deserve further investigation.


Assuntos
Hipocinesia/etiologia , Hipocinesia/fisiopatologia , Extremidade Inferior/fisiopatologia , Doença de Parkinson/complicações , Doença de Parkinson/fisiopatologia , Idoso , Feminino , Humanos , Masculino
16.
Int J Imaging Syst Technol ; 21(3): 247-252, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28936032

RESUMO

Described herein are the advantages of using sub-sinograms for single photon emission computed tomography image reconstruction. A sub-sinogram is a sinogram acquired with an entire data acquisition protocol, but in a fraction of the total acquisition time. A total-sinogram is the summation of all sub-sinograms. Images can be reconstructed from the total-sinogram or from sub-sinograms and then be summed to produce the final image. For a linear reconstruction method such as the filtered backprojection algorithm, there is no advantage of using sub-sinograms. However, for nonlinear methods such as the maximum likelihood (ML) expectation maximization algorithm, the use of sub-sinograms can produce better results. The ML estimator is a random variable, and one ML reconstruction is one realization of the random variable. The ML solution is better obtained via the mean value of the random variable of the ML estimator. Sub-sinograms can provide many realizations of the ML estimator. We show that the use of sub-sinograms can produce better estimations for the ML solution than can the total-sinogram and can also reduce the statistical noise within iteratively reconstructed images.

17.
J Med Syst ; 35(2): 189-201, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20703570

RESUMO

We measured the electrical activity signals of the heart through vital signs monitoring garments that have textile electrodes in conductive yarns while the subject is in stable and dynamic motion conditions. To measure the electrical activity signals of the heart during daily activities, four types of monitoring garment were proposed. Two experiments were carried out as follows: the first experiment sought to discover which garment led to the least displacement of the textile electrode from its originally intended location on the wearer's body. In the second, we measured and compared the electrical activity signals of the heart between the wearer's stable and dynamic motion states. The results indicated that the most appropriate type of garment sensing-wise was the "cross-type", and it seems to stabilize the electrode's position more effectively. The value of SNR of ECG signals for the "cross-type" garment is the highest. Compared to the "chest-belt-type" garment, which has already been marketed commercially, the "cross-type" garment was more efficient and suitable for heart activity monitoring.


Assuntos
Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Coração/fisiologia , Têxteis , Vestuário , Eletrodos , Humanos
18.
J Med Syst ; 34(5): 959-66, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20703612

RESUMO

A portable and wireless activity monitoring system was developed for the estimation of temporal gait parameters. The new system was built using three-axis accelerometers to automatically detect walking steps with various walking speeds. The accuracy of walking step-peak detection algorithm was assessed by using a running machine with variable speeds. To assess the consistency of gait parameter analysis system, estimated parameters, such as heel-contact and toe-off time based on accelerometers and footswitches were compared for consecutive 20 steps from 19 individual healthy subjects. Accelerometers and footswitches had high consistency in the temporal gait parameters. The stance, swing, single-limb support, and double-limb support time of gait cycle revealed ICCs values of 0.95, 0.93, 0.86, and 0.75 on the right and 0.96, 0.86, 0.93, 0.84 on the left, respectively. And the walking step-peak detection accuracy was 99.15% (±0.007) for the proposed method compared to 87.48% (±0.033) for a pedometer. Therefore, the proposed activity monitoring system proved to be a reliable and useful tool for identification of temporal gait parameters and walking pattern classification.


Assuntos
Marcha/fisiologia , Monitorização Ambulatorial/instrumentação , Caminhada/fisiologia , Adulto , Algoritmos , Desenho de Equipamento , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Tecnologia sem Fio
19.
Disabil Rehabil Assist Technol ; 5(4): 247-53, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20302417

RESUMO

PURPOSE: The purpose of this study is to develop an automatic human movement classification system for the elderly using single waist-mounted tri-axial accelerometer. METHODS: Real-time movement classification algorithm was developed using a hierarchical binary tree, which can classify activities of daily living into four general states: (1) resting state such as sitting, lying, and standing; (2) locomotion state such as walking and running; (3) emergency state such as fall and (4) transition state such as sit to stand, stand to sit, stand to lie, lie to stand, sit to lie, and lie to sit. To evaluate the proposed algorithm, experiments were performed on five healthy young subjects with several activities, such as falls, walking, running, etc. RESULTS: The results of experiment showed that successful detection rate of the system for all activities were about 96%. To evaluate long-term monitoring, 3 h experiment in home environment was performed on one healthy subject and 98% of the movement was successfully classified. CONCLUSIONS: The results of experiment showed a possible use of this system which can monitor and classify the activities of daily living. For further improvement of the system, it is necessary to include more detailed classification algorithm to distinguish several daily activities.


Assuntos
Aceleração , Sistemas Computacionais , Monitorização Ambulatorial/instrumentação , Acidentes por Quedas , Atividades Cotidianas , Fatores Etários , Idoso , Algoritmos , Fenômenos Biomecânicos , Desenho de Equipamento , Humanos , Locomoção , Postura/fisiologia , Descanso/fisiologia , Fatores de Risco , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Caminhada/fisiologia
20.
Comput Methods Programs Biomed ; 96(2): 125-32, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19439390

RESUMO

The very first step for keeping good dental hygiene is to employ the correct toothbrushing style. Due to the possible occurrence of periodontal disease at an early age, it is critical to begin correct toothbrushing patterns as early as possible. With this aim, we proposed a novel toothbrush monitoring and training system to interactively educate on toothbrushing behavior in terms of the correct brushing motion and grip axis orientation. Our intelligent toothbrush monitoring system first senses a user's brushing pattern by analyzing the waveforms acquired from a built-in accelerometer and magnetic sensor. To discern the inappropriate toothbrushing style, a real-time interactive three dimensional display system, based on an OpenGL 3D surface rendering scheme, is applied to visualize a subject's brushing patterns and subsequently advise on the correct brushing method.


Assuntos
Instrução por Computador/instrumentação , Instrução por Computador/métodos , Educação em Saúde Bucal/métodos , Imageamento Tridimensional/métodos , Higiene Bucal/educação , Escovação Dentária/métodos , Interface Usuário-Computador , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Imageamento Tridimensional/instrumentação , Modelos Biológicos , Educação de Pacientes como Assunto/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Escovação Dentária/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA