Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Mar Drugs ; 21(12)2023 Nov 29.
Artigo em Inglês | MEDLINE | ID: mdl-38132945

RESUMO

Muscle atrophy is a complex physiological condition caused by a variety of reasons, including muscle disuse, aging, malnutrition, chronic diseases, immobilization, and hormonal imbalance. Beyond its effect on physical appearance, this condition significantly reduces the quality of human life, thus warranting the development of preventive strategies. Although exercising is effective in managing this condition, it is applicable only for individuals who can engage in physical activities and are not bedridden. A combination of exercise and nutritional supplementation has emerged as a more advantageous approach. Here, we evaluated the effects of enzyme-assisted hydrolysates of Mytilus edulis prepared using Protamex (PMH), Alcalase (AMH), or Flavourzyme (FMH) in protecting against muscle atrophy in a dexamethasone (Dex)-induced muscular atrophy model in vitro and in vitro. Alcalase-assisted M. edulis hydrolysate (AMH) was the most efficient among the tested treatments and resulted in higher protein recovery (57.06 ± 0.42%) and abundant amino acid composition (43,158 mg/100 g; 43.16%). AMH treatment also escalated the proliferation of C2C12 cells while increasing the total number of nuclei, myotube coverage, and myotube diameter. These results were corroborated by a successful reduction in the levels of proteins responsible for muscle atrophy, including E3 ubiquitin ligases, and an increase in the expression of proteins associated with muscle hypertrophy, including myogenin and MyHC. These results were further solidified by the successful enhancement of locomotor ability and body weight in zebrafish following AMH treatment. Thus, these findings highlight the potential of AMH in recovery from muscle atrophy.


Assuntos
Mytilus edulis , Animais , Humanos , Subtilisinas , Peixe-Zebra , Atrofia Muscular/tratamento farmacológico , Atrofia Muscular/prevenção & controle , Atrofia Muscular/induzido quimicamente , Fibras Musculares Esqueléticas , Músculo Esquelético
2.
J Oral Maxillofac Surg ; 76(6): 1370-1376, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29294354

RESUMO

PURPOSE: The purpose of this study was to compare the daily food intake rate and the rate of screw loosening between 2 groups of rabbits with mandibular continuity defects: custom implant (CI) group and 5-hole mini-plate group. MATERIALS AND METHODS: Two types of cylindrical implants were printed, and their physical strength was compared. In this study using rabbits, 1 group (n = 5) received a CI for the reconstruction of a mandibular continuity defect (CI group) and the other group (n = 5) received a 5-hole mini-plate without a bone graft (reconstruction plate [RP] group). After reconstruction, the daily food intake rate and the rate of screw loosening were examined postoperatively. Histologic examination in the CI group was performed 3 months after the operation. RESULTS: The design that mimicked the mandible showed greater physical strength. The amount of time required to achieve 50% recovery was shorter in the CI group than in the RP group (P = .011). The total number of loosened screws in the CI group was lower than that in the RP group at 3 months postoperatively (P = .008). New bone formation in the porous CI was evident in the CI group. CONCLUSIONS: Rabbits with mandibular continuity defects treated with CIs for reconstruction showed faster recovery of the daily food intake rate and fewer loosened screws than those treated with a 5-hole mini-plate without bone graft.


Assuntos
Placas Ósseas , Reconstrução Mandibular , Desenho de Prótese , Animais , Coelhos , Tomografia Computadorizada de Feixe Cônico , Ingestão de Alimentos , Reconstrução Mandibular/instrumentação , Impressão Tridimensional , Falha de Prótese , Distribuição Aleatória , Telas Cirúrgicas
3.
J Oral Maxillofac Surg ; 72(10): 1928-36, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25234528

RESUMO

PURPOSE: The objective of this study was to compare bone formation after installation of uncoated (UC), hydroxyapatite-coated (HA), collagen plus HA-coated (CH), and silk plus HA-coated (SH) implants. MATERIALS AND METHODS: Implants in the UC group had acid-etched surfaces. Surface coating was applied using the aerosol deposition method. Cellular responses on the coated surfaces were examined with scanning electron microscopy. Cellular responses to the surfaces were studied with the corresponding coated discs and MG63 cells. Subsequently, 3-(4, 5-dimethylthiazole-2-yl)-2,5-diphenyltetrazolium bromide (MTT) and alkaline phosphatase (ALP) assays were performed. Peri-implant bone formation was evaluated with the rabbit tibia model. Twenty-four implants from each group were installed. The animals were sacrificed 6 weeks after implant installation. Peri-implant bone formation and implant-to-bone contact were measured in histologic sections. Significance of differences across groups was evaluated using analysis of variance. RESULTS: Scanning electron microscopic images showed that the CH and SH groups exhibited cells that appeared more spread out than those in the other groups. The SH group exhibited the highest value in the MTT assay. The CH group exhibited the highest level of ALP activity. Comparisons of these modifications with the acid-etched surfaces showed that the CH and SH groups displayed significantly greater peri-implant bone formation (P < .001). CONCLUSION: The SH group displayed significantly greater new bone formation and bone-to-implant contact than did the other groups.


Assuntos
Materiais Revestidos Biocompatíveis/química , Colágeno Tipo I/química , Implantes Dentários , Durapatita/química , Osteogênese/fisiologia , Seda/química , Condicionamento Ácido do Dente/métodos , Aerossóis , Fosfatase Alcalina/análise , Animais , Adesão Celular/fisiologia , Técnicas de Cultura de Células , Linhagem Celular , Movimento Celular/fisiologia , Corantes , Materiais Dentários/química , Planejamento de Prótese Dentária , Microscopia Eletrônica de Varredura , Osseointegração/fisiologia , Osteoblastos/fisiologia , Coelhos , Propriedades de Superfície , Sais de Tetrazólio , Tiazóis , Titânio/química
4.
J Oral Maxillofac Surg ; 72(1): 53-60, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24331565

RESUMO

PURPOSE: The objective of this study was to compare peri-implant bone formation among uncoated (UC), hydroxyapatite (HA), collagen plus HA (CH), and collagen, HA, plus bone morphogenetic protein-2 (BMP-2) implant groups. MATERIALS AND METHODS: Implants in the UC group had acid-etched surfaces. The surface coating was applied using the aerosol deposition method. The coated surfaces were examined by scanning electron microscopy, x-ray diffraction (XRD), and Fourier-transformed infrared absorption analysis. Subsequently, 6 implants from each group (total, 24 implants) were installed in the tibias of rabbits. The animals were sacrificed at 6 weeks after implant installation. Peri-implant bone formation and bone-to-implant contact (BIC) were measured in histologic sections. Significant differences among groups were evaluated using analysis of variance. RESULTS: Based on the measured XRD patterns, there was a characteristic HA phase (International Centre for Diffraction Data [ICDD], 086-0740) coated on the titanium (ICDD, 089-3725). Subsequent coating processes for collagen and BMP-2 did not display additional diffraction peaks, but maintained the diffraction patterns of the HA-coated titanium. The presence of collagen was verified by infrared absorption analysis. When comparing these modifications with UC surfaces, only the CH coating displayed significantly greater peri-implant bone formation and BIC (P = .003 and P < .001, respectively). Adding BMP-2 to the implant surface did not produce any advantage compared with the CH coating. CONCLUSIONS: In this study, the CH group displayed significantly greater new bone formation and BIC than the other groups. There was no significant difference among the other groups.


Assuntos
Proteína Morfogenética Óssea 2/química , Materiais Revestidos Biocompatíveis/química , Colágeno Tipo I/química , Implantes Dentários , Planejamento de Prótese Dentária , Durapatita/química , Osteogênese/fisiologia , Condicionamento Ácido do Dente/métodos , Aerossóis , Animais , Materiais Dentários/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Osseointegração/fisiologia , Coelhos , Espectroscopia de Infravermelho com Transformada de Fourier , Propriedades de Superfície , Tíbia/patologia , Tíbia/cirurgia , Titânio/química , Difração de Raios X
5.
Tumour Biol ; 34(3): 1595-603, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23412976

RESUMO

The present study was undertaken to examine the effects of cisplatin plus 4-hexylresorcinol (4-HR) combination therapy on oral mucosal melanoma (OMM) using cultured primary OMM cells in a tumour xenograft model. Cultured primary OMM cells were used for the MTT assay and DNA microarray. OMM cells were implanted into the submandibular glands of nude mice. The mice were then treated with cisplatin only or cisplatin plus 4-HR. Tumour size changes, survival rate and tumour metastasis were compared between the two groups by observation, micro-positron emission tomography (PET) and histological examination. In the MTT assay, the cisplatin plus 4-HR group showed significantly higher inhibition of OMM cell growth compared to the other groups (p<0.05). DNA microarray results showed significant inhibition of matrix metalloproteinase (MMP)-2 gene expression upon 4-HR application. The necropsy and micro-PET results showed that the mice from the cisplatin-only group had more distant metastases than the mice from the cisplatin plus 4-HR combination group (p=0.002). MMP-2 expression was lower in the primary tumours in the cisplatin plus 4-HR combination group than in the cisplatin-only group (p<0.001). Overall survival was longer in mice from the cisplatin plus 4-HR combination group than in the cisplatin-only group (p=0.049). In conclusion, the combined effect of cisplatin and 4-HR resulted in fewer metastases and longer survival than cisplatin-only treatment in the OMM xenograft model.


Assuntos
Apoptose/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Cisplatino/farmacologia , Modelos Animais de Doenças , Hexilresorcinol/farmacologia , Melanoma Experimental/mortalidade , Neoplasias Bucais/mortalidade , Animais , Anti-Helmínticos/farmacologia , Antineoplásicos/farmacologia , Protocolos de Quimioterapia Combinada Antineoplásica , Biomarcadores Tumorais/genética , Biomarcadores Tumorais/metabolismo , Sinergismo Farmacológico , Perfilação da Expressão Gênica , Humanos , Técnicas Imunoenzimáticas , Masculino , Melanoma Experimental/tratamento farmacológico , Melanoma Experimental/patologia , Camundongos , Camundongos Nus , Mucosa Bucal/efeitos dos fármacos , Mucosa Bucal/patologia , Neoplasias Bucais/tratamento farmacológico , Neoplasias Bucais/patologia , Análise de Sequência com Séries de Oligonucleotídeos , Células Tumorais Cultivadas , Ensaios Antitumorais Modelo de Xenoenxerto
6.
J Craniofac Surg ; 24(6): 1927-30, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24220375

RESUMO

The objective of this study was to demonstrate that a silk fibroin (SF) and 4-hexylresorcinol (4-HR) incorporation membrane could be used for a guided bone regeneration technique. Fourier transform infrared measurements were obtained to determine change of physical property of SF membrane by 4-HR incorporation. Two peri-implant defects, 3.0 × 5.0 mm (width × length), were prepared on the lateral side of the implant hole in the tibia of New Zealand white rabbits (n = 8). The peri-implant defect was left unfilled in the control group. Silk fibroin + 4-HR membrane was applied to the peri-implant defect in the experimental group. The 8 animals were killed at 8 weeks after implantation. Subsequently, removal torque test and histomorphometric evaluation were done. Fourier transform infrared spectroscopy showed no specific chemical interaction between 4-HR and SF. In the histomorphometric analysis, the mean bone regeneration was 18.3 ± 1.9 mm(2) in the experimental group and 9.3 ± 0.9 mm(2) in the control group (P = 0.004). In conclusion, the SF and 4-HR incorporation membrane successfully regenerated bone in the rabbit tibia peri-implant bone defect model.


Assuntos
Regeneração Óssea/fisiologia , Fibroínas/uso terapêutico , Regeneração Tecidual Guiada/instrumentação , Hexilresorcinol/uso terapêutico , Membranas Artificiais , Animais , Doenças Ósseas/patologia , Doenças Ósseas/terapia , Implantação Dentária Endóssea/métodos , Implantes Dentários , Fibroínas/química , Hexilresorcinol/química , NF-kappa B/antagonistas & inibidores , Osteogênese/fisiologia , Coelhos , Seda , Espectroscopia de Infravermelho com Transformada de Fourier , Tíbia/patologia , Tíbia/cirurgia , Fatores de Tempo , Torque
7.
Nano Lett ; 12(9): 4775-83, 2012 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-22908907

RESUMO

The formation of a two-dimensional electron gas (2-DEG) using SrTiO(3) (STO)-based heterostructures provides promising opportunities in oxide electronics. We realized the formation of 2-DEG using several amorphous layers grown by the atomic layer deposition (ALD) technique at 300 °C which is a process compatible with mass production and thereby can provide the realization of potential applications. We found that the amorphous LaAlO(3) (LAO) layer grown by the ALD process can generate 2-DEG (∼1 × 10(13)/cm(2)) with an electron mobility of 4-5 cm(2)/V·s. A much higher electron mobility was observed at lower temperatures. More remarkably, amorphous YAlO(3) (YAO) and Al(2)O(3) layers, which are not polar-perovskite-structured oxides, can create 2-DEG as well. 2-DEG was created by means of the important role of trimethylaluminum, Me(3)Al, as a reducing agent for STO during LAO and YAO ALD as well as the Al(2)O(3) ALD process at 300 °C. The deposited oxide layer also plays an essential role as a catalyst that enables Me(3)Al to reduce the STO. The electrons were localized very near to the STO surface, and the source of carriers was explained based on the oxygen vacancies generated in the STO substrate.


Assuntos
Alumínio/química , Cristalização/métodos , Nanoestruturas/química , Nanoestruturas/ultraestrutura , Gases em Plasma/química , Estrôncio/química , Titânio/química , Substâncias Macromoleculares/química , Conformação Molecular , Tamanho da Partícula
8.
Antioxidants (Basel) ; 12(9)2023 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-37760060

RESUMO

Olive flounder (OF) is a widely aqua-cultivated and recognized socioeconomic resource in Korea. However, more than 50% of by-products are generated when processing one OF, and there is no proper way to utilize them. With rising awareness and interest in eco-friendly bio-materialization recycling, this research investigates the potential of enzymatic hydrolysis of OF by-products (OFB) to produce functional ingredients. Various enzymatic hydrolysates of OFB (OFBEs) were generated using 11 commercial enzymes. Among them, Prozyme 2000P-assisted OFBE (OFBP) exhibited the highest protein content and yield, as well as low molecularization. The muscle regenerative potential of OFBEs was evaluated using C2C12 myoblasts, revealing that OFBP positively regulated myoblast differentiation. In an in vitro Dex-induced myotube atrophy model, OFBP protected against muscle atrophy and restored myotube differentiation and Dex-induced reactive oxygen species (ROS) production. Furthermore, zebrafish treated with OFBEs showed improved locomotor activity and body weight, with OFBP exhibiting outstanding restoration in the Dex-induced muscle atrophy zebrafish in vivo model. In conclusion, OFBEs, particularly OFBP, produce hydrolysates with enhanced physiological usability and muscle regenerative potential. Further research on its industrial application and mechanistic insights is needed to realize its potential as a high-quality protein food ingredient derived from OF processing by-products.

9.
J Adv Prosthodont ; 13(3): 127-135, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34234922

RESUMO

PURPOSE: The aim of this study is to compare the hardness according to the conditions of metal alloys. Moreover, the correlation between the cast crown hardness before and after wear testing and the degree of wear for each dental alloy was assessed. MATERIALS AND METHODS: Cast crowns of three metal alloys (Co-Cr, gold, and Ni-Cr alloys) opposing smooth-surface monolithic zirconia were used. The Vickers microhardness of the ingot (which did not undergo wear testing) and the cast crown before and after wear testing were measured for each alloy. Two-way ANOVA and Scheffé tests were used to compare the measured hardness values. Moreover, the Pearson correlation coefficient was used to evaluate the relationship between the surface hardness and the wear of the cast crown (α=.05). RESULTS: There was no significant difference in the hardness before and after wear testing for the gold alloy (P>.05); however, the hardness of the worn surface of the cast crown increased compared to that of the cast crown before the wear tests of Ni-Cr and Co-Cr alloys (P<.05). Furthermore, there was no correlation between the wear and hardness of the cast crown before and after wear testing for all three metal alloys (P>.05). CONCLUSION: There was a significant difference in hardness between dental alloys under the same conditions. No correlation existed between the surface hardness of the cast crown before and after wear testing and the wear of the cast crown.

10.
ACS Appl Mater Interfaces ; 13(51): 61809-61817, 2021 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-34910869

RESUMO

Metal thin films have been widely used as conductors in semiconductor devices for several decades. However, the resistivity of metal thin films such as Cu and TiN increases substantially (>1000%) as they become thinner (<10 nm) when using high-density integration to improve device performance. In this study, the resistivities of MAX-phase V2AlC films grown on sapphire substrates exhibited a significantly weaker dependence on the film thickness than conventional metal films that resulted in a resistivity increase of only 30%, as the V2AlC film thickness decreased from approximately 45 to 5 nm. The resistivity was almost identical for film thicknesses of 10-50 nm. The small change in the resistivity of V2AlC films with decreasing film thickness originated from the highly ordered crystalline quality and a small electron mean free path (11-13.6 nm). Thus, MAX-phase thin films have great potential for advanced metal technology applications to overcome the current scaling limitations of semiconductor devices.

11.
J Clin Med ; 10(8)2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33920914

RESUMO

INTRODUCTION: this study aimed to investigate the long-term clinical efficacy and satisfaction degree of integrative Korean medicine (KM) treatment for patients with failed back surgery syndrome (FBSS). METHODS: we performed a follow-up questionnaire survey and retrospective analysis of medical records for patients with FBSS who underwent inpatient treatment for ≥ 1 week. The primary evaluation indices were numeric rating scale (NRS) scores for low back pain (LBP) and leg pain at admission and discharge. Sub-evaluation indices included the Oswestry Disability Index (ODI) and EuroQol 5-dimension (EQ-5D) score. The follow-up questionnaire survey obtained information regarding previous surgeries; reasons for satisfaction/dissatisfaction with surgical and KM treatment; and current status. RESULTS: compared with at admission, there was a significant post-treatment decrease in the NRS scores for LBP and leg pain, as well as the ODI score. Further, there was a significant post-treatment increase in the EQ-5D score. Regarding the patients' global impression of change for KM treatment administered during admission and at the follow-up questionnaire survey, 101 (95.3%) patients selected "minimally improved" or better. CONCLUSION: integrative KM treatment could effectively reduce pain, as well as improve function and health-related quality of life, in patients with FBSS.

12.
ACS Appl Mater Interfaces ; 11(33): 30028-30036, 2019 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-31343152

RESUMO

This research demonstrates, for the first time, the development of highly uniform resistive switching devices with self-compliance current for conductive bridge random access memory using two-dimensional electron gas (2DEG) at the interface of an Al2O3/TiO2 thin-film heterostructure via atomic layer deposition (ALD). The cell is composed of Cu/Ti/Al2O3/TiO2, where Cu/Ti and Al2O3 overlayers are used as the active/buffer metals and solid electrolyte, respectively, and the 2DEG at the interface of Al2O3/TiO2 heterostructure, grown by the ALD process, is adopted as a bottom electrode. The Cu/Ti/Al2O3/TiO2 device shows reliable resistive switching characteristics with excellent uniformity under a repetitive voltage sweep (direct current sweep). Furthermore, it exhibits a cycle endurance over 107 cycles under short pulse switching. Remarkably, a reliable operation of multilevel data writing is realized up to 107 cycles. The data retention time is longer than 106 s at 85 °C. The uniform resistance switching characteristics are achieved via the formation of small (∼a few nm width) Cu filament with a short tunnel gap (<0.5 nm) owing to the 2DEG at the Al2O3/TiO2 interface. The performance and operation scheme of this device may be appropriate in neuromorphic applications.

13.
ACS Nano ; 12(10): 10403-10409, 2018 Oct 23.
Artigo em Inglês | MEDLINE | ID: mdl-30204410

RESUMO

We report the field-effect transistors using quasi-two-dimensional electron gas generated at an ultrathin (∼10 nm) Al2O3/TiO2 heterostructure interface grown via atomic layer deposition (ALD) on a SiO2/Si substrate without using a single crystal substrate. The 2DEG at the Al2O3/TiO2 interface originates from oxygen vacancies generated at the surface of the TiO2 bottom layer during ALD of the Al2O3 overlayer. High-density electrons (∼1014 cm-2) are confined within a ∼2.2 nm distance from the Al2O3/TiO2 interface, resulting in a high on-current of ∼12 µA/µm. The ultrathin TiO2 bottom layer is easy to fully deplete, allowing an extremely low off-current, a high on/off current ratio over 108, and a low subthreshold swing of ∼100 mV/decade. Via the implementation of ALD, a mature thin-film process can facilitate mass production as well as three-dimensional integration of the devices.

14.
J Korean Assoc Oral Maxillofac Surg ; 43(1): 49-52, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28280711

RESUMO

Subcutaneous facial emphysema after dental treatment is an uncommon complication caused by the invasion of high-pressure air; in severe cases, it can spread to the neck, mediastinum, and thorax, resulting in cervical emphysema, pneumomediastinum, and pneumothorax. The present case showed subcutaneous cervicofacial emphysema with pneumomediastinum after class V restoration. The patient was fully recovered after eight days of conservative treatment. The cause of this case was the penetration of high-pressure air through the gingival sulcus, which had a weakened gingival attachment. This case indicated that dentists should be careful to prevent subcutaneous emphysema during common dental treatments using a high-speed hand piece and gingival retraction cord.

15.
J Adv Prosthodont ; 9(2): 138-142, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28435624

RESUMO

In restorative treatment using fixed dental prostheses, dentists should select appropriate restoration material among various types of dental materials. The strength, marginal fit, esthetics, wear resistance, biocompatibility, and cost are important factors in the choice of restoration materials. The present case showed a surface stain on a monolithic zirconia restoration that was due to wear between the monolithic zirconia restoration and the base metal alloy restoration. This phenomenon was confirmed by surface roughness measurement and electron probe micro-analysis.

16.
ACS Appl Mater Interfaces ; 9(50): 44053-44059, 2017 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-29188997

RESUMO

We investigate the interaction of carbon nanotubes (CNTs) embedded in a polymer matrix [poly(methyl methacrylate) (PMMA)] with Ar plasma, which results in the formation of PMMA nanostructures, as CNTs act as an etching mask. Because of the large differences in the Ar ion sputtering yields between CNTs and PMMA, PMMA lines with the width comparable to that of CNTs and as high as 20 nm (for single-walled CNTs) or 80 nm (for multiwalled CNTs) can be obtained after repeated exposure of CNT/PMMA films to Ar plasma. We also follow the etching process by investigating changes in the IV characteristics and Raman spectra of CNTs after each exposure to Ar plasma, which shows progressive defect generations in CNTs while they maintain structural integrity long enough to act as the etching mask for PMMA underneath. We demonstrate that the PMMA nanostructure patterns can be transferred to a different polymer substrate using nanoimprinting.

17.
ACS Appl Mater Interfaces ; 9(1): 537-547, 2017 Jan 11.
Artigo em Inglês | MEDLINE | ID: mdl-27936581

RESUMO

The growth characteristics of Ta2O5 thin films by atomic layer deposition (ALD) were examined using Ta(NtBu)(NEt2)3 (TBTDET) and Ta(NtBu)(NEt2)2Cp (TBDETCp) as Ta-precursors, where tBu, Et, and Cp represent tert-butyl, ethyl, and cyclopentadienyl groups, respectively, along with water vapor as oxygen source. The grown Ta2O5 films were amorphous with very smooth surface morphology for both the Ta-precursors. The saturated ALD growth rates of Ta2O5 films were 0.77 Å cycle-1 at 250 °C and 0.67 Å cycle-1 at 300 °C using TBTDET and TBDETCp precursors, respectively. The thermal decomposition of the amido ligand (NEt2) limited the ALD process temperature below 275 °C for TBTDET precursor. However, the ALD temperature window could be extended up to 325 °C due to a strong Ta-Cp bond for the TBDETCp precursor. Because of the improved thermal stability of TBDETCp precursor, excellent nonuniformity of ∼2% in 200 mm wafer could be achieved with a step coverage of ∼90% in a deep hole structure (aspect ratio 5:1) which is promising for 3-dimensional architecture to form high density memories. Nonetheless, a rather high concentration (∼7 at. %) of carbon impurities was incorporated into the Ta2O5 film using TBDETCp, which was possibly due to readsorption of dissociated ligands as small organic molecules in the growth of Ta2O5 film by ALD. Despite the presence of high carbon concentration which might be an origin of large leakage current under electric fields, the Ta2O5 film using TBDETCp showed a promising resistive switching performance with an endurance cycle as high as ∼17 500 for resistance switching random access memory application. The optical refractive index of the deposited Ta2O5 films was 2.1-2.2 at 632.8 nm using both the Ta-precursors, and indirect optical band gap was estimated to be ∼4.1 eV for both the cases.

18.
Maxillofac Plast Reconstr Surg ; 37(1): 32, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26709373

RESUMO

BACKGROUND: The aims of present study were (1) to evaluate new bone formation among the 4-hexylresorcinol (4HR)-incorporated silk fabric membrane (SFM), conventional SFM, and uncovered control groups and (2) to compare the amount of residual membrane between the 4HR-incorporated SFM and conventional SFM in a rabbit parietal defect model. METHODS: Nine New Zealand white rabbits were used for this animal study. After the formation of a bilateral parietal bone defect (diameter 8.0 mm), either 4HR-incorporated SFM or conventional SFM was grafted into the defect. The defect in the control was left uncovered. New bone formation and the amount of residual membrane were evaluated by histomorphometry at 8 weeks after the operation. RESULTS: The total amount of new bone was 37.84 ± 8.30 % in the control, 56.64 ± 15.74 % in the 4HR-incorporated SFM group, and 53.35 ± 10.52 % in the conventional SFM group 8 weeks after the operation. The differences were significant between the control and 4HR-incorporated SFM group (P = 0.016) and between the control and conventional SFM group (P = 0.040). The residual membrane was 75.08 ± 10.52 % in the 4HR-incorporated SFM group and 92.23 ± 5.46 % in the conventional SFM group 8 weeks after the operation. The difference was significant (P = 0.039). CONCLUSIONS: The 4HR-incorporated SFM and conventional SFM groups showed more bone regeneration than the control group. The incorporated 4HR accelerated the partial degradation of the silk fabric membrane in a rabbit parietal defect model 8 weeks after the operation.

19.
Maxillofac Plast Reconstr Surg ; 36(6): 239-46, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27489841

RESUMO

Many kinds of membrane have been used for the guided bone regeneration (GBR) technique. However, most membranes do not fulfill all requirements for the ideal membrane for the GBR technique. Among them, collagen membrane has been most widely used. However, its high price and weak tensile strength in wet condition are limitations for wide clinical application. Synthetic polymers have also been used for the GBR technique. Recently, silk based membrane has been considered as a membrane for the GBR technique. Despite many promising preclinical data for use of a silk membrane, clinical data regarding the silk membrane has been limited. However, silk based material has been used clinically as vessel-tie material and an electrospun silk membrane was applied successfully to patients. No adverse effect related to the silk suture has been reported. Considering that silk membrane can be provided to patients at a cheap price, its clinical application should be encouraged.

20.
J Craniomaxillofac Surg ; 42(5): e245-51, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24135001

RESUMO

INTRODUCTION: The aim of this study was to compare a carbon plate (CP) and a titanium mandibular reconstruction plate (TMRP) in finite element analysis and an animal model. MATERIALS AND METHODS: Twelve rabbits were used for this experiment. After a mandible continuity defect was created, either a CP or a TMRP was used for mandibular reconstruction. Postoperatively, daily feed intake amount (DFIA) was measured for 4 weeks. Radiographic images were also acquired to evaluate screw loosening. For the analysis of the stress distribution, a simple continuity defect model was used, and finite element analysis was performed. RESULTS: The CP group had 0.80 ± 0.45 lost screws in an animal during the 4 weeks postoperative observation; however, the TMRP group had 1.86 ± 0.69 lost screws (p = 0.014). Overall, the 5 out of 5 of rabbits in the CP group and 3 out of 7 in the TMRP group exhibited preoperative levels of DFIA during the 4 week observation (p = 0.038). The finite element analysis showed that the stress was more evenly distributed in the CP than in the TMRP model. CONCLUSIONS: The CP group showed decreased screw loosening and increased recovery of preoperative DFIA compared to the TMRP group in a rabbit model of mandibular continuity defects. Perfect adaptation of CP during the operation could not be achieved in spite of reshaping to the mandibular curvature. This disadvantage of the CP system can be overcome by the prefabricated technique using a prototype model.


Assuntos
Materiais Biocompatíveis/química , Placas Ósseas , Carbono/química , Ingestão de Alimentos/fisiologia , Doenças Mandibulares/cirurgia , Reconstrução Mandibular/instrumentação , Animais , Fenômenos Biomecânicos , Parafusos Ósseos , Fibra de Carbono , Modelos Animais de Doenças , Módulo de Elasticidade , Desenho de Equipamento , Falha de Equipamento , Análise de Elementos Finitos , Temperatura Alta , Doenças Mandibulares/diagnóstico por imagem , Doenças Mandibulares/fisiopatologia , Microscopia Eletrônica de Varredura , Coelhos , Radiografia , Estresse Mecânico , Propriedades de Superfície , Titânio/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA