Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 142
Filtrar
1.
Gesundheitswesen ; 80(5): 471-481, 2018 May.
Artigo em Alemão | MEDLINE | ID: mdl-28561182

RESUMO

AIM OF THE STUDY: The aim of this paper was to conduct a systematic review of cost-of-illness studies for overweight and adiposity in Germany. METHODS: We conducted a PubMed search to identify relevant studies. To increase comparability, all cost data were inflated to 2014 prices. For bottom-up studies, we additionally calculated relative cost-differences between normal weight and overweight, as well as adiposity. These relative differences were pooled using meta-analytical techniques and extrapolated to the German population. RESULTS: We identified 15 bottom-up studies, 6 top-down studies and 2 Markov simulations. On average, top-down studies reported direct costs of 7.9 billion Euros and indirect costs of 3.6 billion Euros. Due to between-study heterogeneity, we were not able to pool absolute costs reported in bottom-up studies. The pooled relative cost-differences for studies conducted with adult persons were +22% for the difference between normal weight and overweight and +53% for the difference between normal weight and adiposity. The corresponding effect sizes were 0.07 (- 0.05; 0.19) and 0.15 (0.02; 0.28), respectively. In studies conducted with children and adolescents, relative cost-differences were considerably smaller with corresponding effect sizes being close to zero. Extrapolation of relative pooled cost-differences from bottom-up studies to the German total population yielded direct and indirect excess costs of 22.2 billion Euros for overweight and 23.0 billion Euros for adiposity. CONCLUSION: We found substantial heterogeneity of cost findings between studies for top-down and bottom-up studies as well, which points to substantial uncertainty and strongly hampers clear statements about the costs of overweight and adiposity. Our findings imply that costs are underestimated by top-down studies, whereas overestimated by our extrapolation. The true costs presumably lie between the findings of both approaches.


Assuntos
Efeitos Psicossociais da Doença , Custos de Cuidados de Saúde , Obesidade , Sobrepeso , Adolescente , Adulto , Criança , Alemanha , Humanos , Obesidade/economia , Sobrepeso/economia
2.
Gesundheitswesen ; 80(8-09): 685-692, 2018 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-28268234

RESUMO

The need for long-term care is expected to increase markedly in the next decades as a result of demographic ageing. Consequently, it is important to know the long-term care preferences. This study investigated the long-term care preferences among older individuals in Germany. Based on a systematic review and expert interviews, a questionnaire was designed to assess long-term care preferences. Data were gathered from a representative telephone survey of the German population (n=1,006; 65 years and above) in 2015. The mean age was 75.2 years (±6.6 years, ranging from 65 to 96 years). While nearly 90% of the individuals preferred home care, other care settings such as nursing care abroad were mostly undesired. In case of home care, most of the individuals preferred care provided by friends/family or formal caregivers, whereas the idea of all-day care services (such as employed private caregivers) was less popular. With respect to home care, additional services such as household assistance, transportation services, and emergency call systems were highly valued by the study participants, whereas continual supervision throughout the day was seen as less important. In case of inpatient care, more than 90% of the individuals preferred a private room, with the inpatient facility located near home or close to relatives' homes. A wide range of activities was appreciated. Given these preferences, it is assumed that there is a gap between expectations (preferences) and reality (utilization) regarding long-term care in Germany. Interventions aimed at minimizing this gap are urgently needed. For example, strategies to raise the awareness of private long-term care provision might be fruitful.


Assuntos
Serviços de Assistência Domiciliar , Assistência de Longa Duração , Preferência do Paciente , Idoso , Cuidadores , Alemanha , Humanos , Casas de Saúde , Inquéritos e Questionários , Revisões Sistemáticas como Assunto
3.
Z Gerontol Geriatr ; 51(6): 612-619, 2018 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-28127636

RESUMO

BACKGROUND: It is well known that individuals in need for care prefer to live at home as long as they can. Due to demographic changes it is predicted that the need for long-term care will considerably increase in the next decades; therefore, it is important to know the potential of informal caregivers. The aim of this study was to investigate the potential for receiving informal care perceived by older individuals and predictive factors associated with it. METHODS: Data were drawn from a population-based telephone survey of the older German population (n = 1006, average age 75.2 ± 6.6 years, range 65-96 years) in 2015. RESULTS: In case of the need for care 71.7% of the individuals had someone who could provide informal care. The potential of informal care was bivariately associated with marital status, having children and self-rated health status. Multiple logistic regression revealed that the potential of informal care was positively associated with having children (odds ratio [OR] 2.5, 95% confidence interval [95% CI] 1.7-3.7), private health insurance (OR 1.7, 95% CI 1.0-2.7), providing informal care for family or friends (OR 1.5, 95% CI 1.1-2.1) and current need of care (OR 2.3, 95% CI 1.1-4.8). CONCLUSION: Besides familial resources, the status of health insurance and the current need of care were important determinants of the potential for informal care. As familial resources are of utmost importance for informal care and it is expected that the geographical distance between family members will increase in the next decades, it is important to develop programs to meet the increasing demand for informal care.


Assuntos
Cuidadores , Assistência ao Paciente , Idoso , Idoso de 80 Anos ou mais , Alemanha , Humanos , Assistência de Longa Duração , Inquéritos e Questionários
4.
Eur Radiol ; 27(2): 705-714, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27236818

RESUMO

OBJECTIVES: To evaluate objective and subjective image quality of a noise-optimized virtual monoenergetic imaging (VMI+) reconstruction technique in dual-energy computed tomography (DECT) angiography prior to transcatheter aortic valve replacement (TAVR). METHODS: Datasets of 47 patients (35 men; 64.1 ± 10.9 years) who underwent DECT angiography of heart and vascular access prior to TAVR were reconstructed with standard linear blending (F_0.5), VMI+, and traditional monoenergetic (VMI) algorithms in 10-keV intervals from 40-100 keV. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of 564 arterial segments were evaluated. Subjective analysis was rated by three blinded observers using a Likert scale. RESULTS: Mean SNR and CNR were highest in 40 keV VMI+ series (SNR, 27.8 ± 13.0; CNR, 26.3 ± 12.7), significantly (all p < 0.001) superior to all VMI series, which showed highest values at 70 keV (SNR, 18.5 ± 7.6; CNR, 16.0 ± 7.4), as well as linearly-blended F_0.5 series (SNR, 16.8 ± 7.3; CNR, 13.6 ± 6.9). Highest subjective image quality scores were observed for 40, 50, and 60 keV VMI+ reconstructions (all p > 0.05), significantly superior to all VMI and standard linearly-blended images (all p < 0.01). CONCLUSIONS: Low-keV VMI+ reconstructions significantly increase CNR and SNR compared to VMI and standard linear-blending image reconstruction and improve subjective image quality in preprocedural DECT angiography in the context of TAVR planning. KEY POINTS: • VMI+ combines increased contrast with reduced image noise. • VMI+ shows substantially less image noise than traditional VMI. • 40-keV reconstructions show highest SNR/CNR of the aortic and iliofemoral access route. • Observers overall prefer 60 keV VMI+ images. • VMI+ DECT imaging helps improve image quality for TAVR planning.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada , Meios de Contraste , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Razão Sinal-Ruído , Cirurgia Assistida por Computador , Substituição da Valva Aórtica Transcateter/métodos
5.
BMC Health Serv Res ; 17(1): 156, 2017 02 21.
Artigo em Inglês | MEDLINE | ID: mdl-28222774

RESUMO

BACKGROUND: Long-term care is one of the most pressing health policy issues in Germany. It is expected that the need for long-term care will increase markedly in the next decades due to demographic shifts. The purpose of this study was to investigate the factors associated with preferences for long-term care settings in old age individuals in Germany. METHODS: Based on expert interviews and a systematic review, a questionnaire was developed to quantify long-term care preferences. Data were drawn from a population-based survey of the German population aged 65 and over in 2015 (n = 1006). RESULTS: In multiple logistic regressions, preferences for home care were positively associated with providing care for family/friends [OR: 1.6 (1.0-2.5)], lower self-rated health [OR: 1.3 (1.0-1.6)], and no current need of care [OR: 5.5 (1.2-25.7)]. Preferences for care in relatives' homes were positively associated with being male [OR: 2.0 (1.4-2.7)], living with partner or spouse [OR: 1.8 (1.3-2.4)], having children [OR: 1.6 (1.0-2.5)], private health insurance [OR: 1.6 (1.1-2.3)], providing care for family/friends [OR: 1.5 (1.1-2.0)], and higher self-rated health [OR: 1.2 (1.0-1.4)]. Preferences for care in assisted living were positively associated with need of care [OR: 1.9 (1.0-3.5)] and higher education [for example, University, OR: 3.5 (1.9-6.5)]. Preferences for care in nursing home/old age home were positively associated with being born in Germany [OR: 1.8 (1.0-3.1)] and lower self-rated health [OR: 1.2 (1.0-1.4)]. Preferences for care in a foreign country were positively associated with lower age [OR: 1.1 (1.0-1.2)] and being born abroad [OR: 5.5 (2.7-11.2)]. CONCLUSIONS: Numerous variables used are sporadically significant, underlining the complex nature of long-term care preferences. A better understanding of factors associated with preferences for care settings might contribute to improving long-term care health services.


Assuntos
Necessidades e Demandas de Serviços de Saúde , Assistência de Longa Duração/psicologia , Preferência do Paciente , Atividades Cotidianas/psicologia , Idoso , Idoso de 80 Anos ou mais , Prática Clínica Baseada em Evidências/organização & administração , Feminino , Alemanha , Serviços de Assistência Domiciliar , Humanos , Expectativa de Vida/tendências , Assistência de Longa Duração/estatística & dados numéricos , Masculino , Casas de Saúde , Qualidade de Vida , Inquéritos e Questionários
6.
Radiology ; 280(2): 510-9, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26928067

RESUMO

Purpose To evaluate whether a dual-energy (DE) computed tomographic (CT) virtual noncalcium technique can improve the detection rate of acute thoracolumbar vertebral compression fractures in patients with osteoporosis compared with that at magnetic resonance (MR) imaging depending on the level of experience of the reading radiologist. Materials and Methods This retrospective study was approved by the institutional ethics committee. Informed consent was obtained from all patients. Forty-nine patients with osteoporosis who were suspected of having acute vertebral fracture underwent DE CT and MR imaging. Conventional linear-blended CT scans and corresponding virtual noncalcium reconstructions were obtained. Five radiologists with varying levels of experience evaluated gray-scale CT scans for the presence of fractures and their suspected age. Then, virtual noncalcium images were evaluated to detect bone marrow edema. Findings were compared with those from MR imaging (the standard of reference). Sensitivity and specificity analyses for diagnostic performance and matched pair analyses were performed on vertebral fracture and patient levels. Results Sixty-two fractures were classified as fresh and 52 as old at MR imaging. The diagnostic performance of all readers in the detection of fresh fractures improved with the addition of virtual noncalcium reconstructions compared with that with conventional CT alone. Although the diagnostic accuracy of the least experienced reader with virtual noncalcium CT (accuracy with CT alone, 61%; accuracy with virtual noncalcium technique, 83%) was within the range of that of the most experienced reader with CT alone, the latter improved his accuracy with the noncalcium technique (from 81% to 95%), coming close to that with MR imaging. The number of vertebrae rated as unclear decreased by 59%-90% or from 15-53 to 2-13 in absolute numbers across readers. The number of patients potentially referred to MR imaging decreased by 36%-87% (from 11-23 to 2-10 patients). Considering the gain in true decisions with the virtual noncalcium technique on a patient level, between 12 (most experienced reader) and 17 (least experienced reader) MR examinations could have been avoided. Conclusion The DE CT-based virtual noncalcium technique may enable depiction of bone marrow edema in thoracolumbar vertebral compression fractures in patients with osteoporosis, with good accordance with MR imaging when images are read by experienced radiologists. Although less experienced readers improved their diagnostic performance to some degree, the experienced reader's diagnostic performance approached that with MR imaging. (©) RSNA, 2016.


Assuntos
Medula Óssea/diagnóstico por imagem , Fraturas por Compressão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Osteoporose/diagnóstico por imagem , Fraturas da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Competência Clínica/estatística & dados numéricos , Edema/complicações , Edema/diagnóstico por imagem , Feminino , Fraturas por Compressão/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Osteoporose/complicações , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Fraturas da Coluna Vertebral/complicações , Coluna Vertebral/diagnóstico por imagem
7.
Eur Radiol ; 26(3): 755-63, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26123407

RESUMO

PURPOSE: To evaluate feasibility of measuring parenchymal blood volume (PBV) of malignant hepatic tumours using C-arm CT, test the changes in PBV following repeated transarterial chemoembolization (TACE) and correlate these changes with the change in tumour size in MRI. METHODS: 111 patients with liver malignancy were included. Patients underwent MRI and TACE in a 4- to 6-week interval. During intervention C-arm CT was performed. Images were post-processed to generate PBV maps. Blood volume data in C-arm CT and change in size in MRI were evaluated. The correlation between PBV and size was tested using Spearman rank test. RESULTS: Pre-interventional PBV maps showed a mean blood volume of 84.5 ml/1000 ml ± 62.0, follow-up PBV maps after multiple TACE demonstrated 61.1 ml/1000 ml ± 57.5. The change in PBV was statistically significant (p = 0.02). Patients with initial tumour blood volume >100 ml/1000 ml dropped 7.1% in size and 47.2% in blood volume; 50-100 ml/1000 ml dropped 4.6% in size and 25.7% in blood volume; and <50 ml/1000 ml decreased 2.8% in size and increased 82.2% in blood volume. CONCLUSION: PBV measurement of malignant liver tumours using C-arm CT is feasible. Following TACE PBV decreased significantly. Patients with low initial PBV show low local response rates and further increase in blood volume, whereas high initial tumour PBV showed better response to TACE. KEY POINTS: Parenchymal blood volume assessment of malignant hepatic lesions using C-arm CT is feasible. The parenchymal blood volume is reduced significantly following transarterial chemoembolization. Parenchymal blood volume can monitor the response of tumours after transarterial chemoembolization. Although not significant, high initial parenchymal blood volume yields better response to TACE.


Assuntos
Quimioembolização Terapêutica/métodos , Neoplasias Hepáticas/terapia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Volume Sanguíneo , Determinação do Volume Sanguíneo , Estudos de Viabilidade , Feminino , Humanos , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Retratamento , Resultado do Tratamento , Carga Tumoral , Adulto Jovem
8.
Eur Radiol ; 26(6): 1863-70, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26334508

RESUMO

OBJECTIVES: To compare quantitative image quality parameters in abdominal dual-energy computed tomography angiography (DE-CTA) using an advanced image-based (Mono+) reconstruction algorithm for virtual monoenergetic imaging and standard DE-CTA. METHODS: Fifty-five patients (36 men; mean age, 64.2 ± 12.7 years) who underwent abdominal DE-CTA were retrospectively included. Mono + images were reconstructed at 40, 50, 60, 70, 80, 90 and 100 keV levels and as standard linearly blended M_0.6 images (60 % 100 kV, 40 % 140 kV). The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) of the common hepatic (CHA), splenic (SA), superior mesenteric (SMA) and left renal arteries (LRA) were objectively measured. RESULTS: Mono+ DE-CTA series showed a statistically superior CNR for 40, 50, 60, 70 and 80 keV (P < 0.031) compared to M_0.6 images for all investigated arteries except SMA at 80 keV (P = 0.08). CNR at 40 keV revealed a mean relative increase of 287.7 % compared to linearly blended images among all assessed arteries (P < 0.001). SNR of Mono+ images was consistently significantly higher at 40, 50, 60 and 70 keV compared to M_0.6 for CHA and SA (P < 0.009). CONCLUSIONS: Compared to linearly blended images, Mono+ reconstructions at low keV levels of abdominal DE-CTA datasets significantly improve quantitative image quality. KEY POINTS: • Mono+ combines increased attenuation with reduced image noise compared to standard DE-CTA. • Mono+ shows superior contrast-to-noise ratios at low keV compared to linearly-blended images. • Contrast-to-noise ratio in monoenergetic DE-CTA peaks at 40 keV. • Mono+ reconstructions significantly improve quantitative image quality at low keV levels.


Assuntos
Cavidade Abdominal/diagnóstico por imagem , Algoritmos , Angiografia por Tomografia Computadorizada/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Razão Sinal-Ruído
9.
J Comput Assist Tomogr ; 40(1): 80-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26466115

RESUMO

OBJECTIVE: The aim of the study was to evaluate objective and subjective image qualities of virtual monoenergetic imaging (VMI) in dual-source dual-energy computed tomography (DECT) and optimal kiloelectron-volt (keV) levels for lung cancer. METHODS: Fifty-nine lung cancer patients underwent chest DECT. Images were reconstructed as VMI series at energy levels of 40, 60, 80, and 100 keV and standard linear blending (M_0.3) for comparison. Objective and subjective image qualities were assessed. RESULTS: Lesion contrast peaked in 40-keV VMI reconstructions (2.5 ± 2.9) and 60 keV (1.9 ± 3.0), which was superior to M_0.3 (0.5 ± 2.7) for both comparisons (P < 0.001). Compared with M_0.3, subjective ratings were highest for 60-keV VMI series regarding general image quality (4.48 vs 4.52; P = 0.74) and increased for lesion demarcation (4.07 vs 4.84; P < 0.001), superior to all other VMI series (P < 0.001). Image sharpness was similar between both series. Image noise was rated superior in the 80-keV and M_0.3 series, followed by 60 keV. CONCLUSIONS: Virtual monoenergetic imaging reconstructions at 60-keV provided the best combination of subjective and objective image qualities in DECT of lung cancer.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Imageamento Tridimensional , Iopamidol/análogos & derivados , Pulmão/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Razão Sinal-Ruído
10.
Eur Radiol ; 25(6): 1714-20, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25481639

RESUMO

OBJECTIVES: To evaluate quantitative dual-energy computed tomography (DECT) for phantomless analysis of cancellous bone mineral density (BMD) of vertebral pedicles and to assess the correlation with pedicle screw pull-out strength. METHODS: Twenty-nine thoracic and lumbar vertebrae from cadaver specimens were examined with DECT. Using dedicated post-processing software, a pedicle screw vector was mapped (R1, intrapedicular segment of the pedicle vector; R2, intermediate segment; R3, intracorporal segment; global, all segments) and BMD was calculated. To invasively evaluate pedicle stability, pedicle screws were drilled through both pedicles and left pedicle screw pull-out strength was measured. Resulting values were correlated using the paired t test and Pearson's linear correlation. RESULTS: Average pedicle screw vector BMD (R1, 0.232 g/cm(3); R2, 0.166 g/cm(3); R3, 0.173 g/cm(3); global, 0.236 g/cm(3)) showed significant differences between R1-R2 (P < 0.002) and R1-R3 (P < 0.034) segments while comparison of R2-R3 did not reach significance (P > 0.668). Average screw pull-out strength (639.2 N) showed a far stronger correlation with R1 (r = 0.80; P < 0.0001) than global BMD (r = 0.42; P = 0.025), R2 (r = 0.37; P = 0.048) and R3 (r = -0.33; P = 0.078) segments. CONCLUSIONS: Quantitative DECT allows for phantomless BMD assessment of the vertebral pedicle. BMD of the intrapedicular segment shows a significantly stronger correlation with pedicle screw pull-out strength than other segments. KEY POINTS: • Quantitative dual-energy CT enables evaluation of pedicle bone mineral density. • Intrapedicular segments show significant differences regarding bone mineral density. • Pedicle screw pull-out strength correlated strongest with R1 values. • Dual-energy CT may improve preoperative assessment before transpedicular screw fixation.


Assuntos
Densidade Óssea/fisiologia , Vértebras Lombares/fisiologia , Parafusos Pediculares , Vértebras Torácicas/fisiologia , Absorciometria de Fóton/métodos , Idoso , Fenômenos Biomecânicos , Cadáver , Estudos de Casos e Controles , Remoção de Dispositivo , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Vértebras Torácicas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
11.
Eur Radiol ; 25(8): 2493-501, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25680727

RESUMO

OBJECTIVES: To define optimal keV settings for advanced monoenergetic (Mono+) dual-energy computed tomography (DECT) in patients with head and neck squamous cell carcinoma (SCC). METHODS: DECT data of 44 patients (34 men, mean age 55.5 ± 16.0 years) with histopathologically confirmed SCC were reconstructed as 40, 55, 70 keV Mono + and M_0.3 (30 % 80 kV) linearly blended series. Attenuation of tumour, sternocleidomastoid muscle, internal jugular vein, submandibular gland, and noise were measured. Three radiologists with >3 years of experience subjectively assessed image quality, lesion delineation, image sharpness, and noise. RESULTS: The highest lesion attenuation was shown for 40 keV series (248.1 ± 94.1 HU), followed by 55 keV (150.2 ± 55.5 HU; P = 0.001). Contrast-to-noise ratio (CNR) at 40 keV (19.09 ± 13.84) was significantly superior to all other reconstructions (55 keV, 10.25 ± 9.11; 70 keV, 7.68 ± 6.31; M_0.3, 5.49 ± 3.28; all P < 0.005). Subjective image quality was highest for 55 keV images (4.53; κ = 0.38, P = 0.003), followed by 40 keV (4.14; κ = 0.43, P < 0.001) and 70 keV reconstructions (4.06; κ = 0.32, P = 0.005), all superior (P < 0.004) to linear blending M_0.3 (3.81; κ = 0.280, P = 0.056). CONCLUSIONS: Mono + DECT at low keV levels significantly improves CNR and subjective image quality in patients with head and neck SCC, as tumour CNR peaks at 40 keV, and 55 keV images are preferred by observers. KEY POINTS: • Mono + DECT combines increased contrast with reduced image noise, unlike linearly blended images. • Mono + DECT imaging allows for superior CNR and subjective image quality. • Head and neck tumour contrast-to-noise ratio peaks at 40 keV. • 55 keV images are preferred over all other series by observers.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Estudos Retrospectivos
12.
AJR Am J Roentgenol ; 205(3): 618-22, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26295650

RESUMO

OBJECTIVE: The purpose of this study was to determine whether iterative reconstruction improves the quality of cranial CT (CCT) images of stroke patients. MATERIALS AND METHODS: Fifty-one CCT studies of patients with infarction performed with either a low (260 mAs; n = 21) or standard (340 mAs; n = 30) dose were reconstructed with both filtered back projection (FBP) and sinogram-affirmed iterative reconstruction (SAFIRE) with five strength levels (S1-S5). The resulting six image sets (one FBP and one each for SAFIRE levels S1-S5) were rated separately by two blinded radiologists in terms of conspicuity of infarcted areas on a 5-point scale. Noise and infarct-to-normal brain as well as medullary-to-cortical contrast-to-noise ratios (CNRs) were measured. Ratings, noise, and CNRs were intraindividually compared within the same dose group (Fisher exact test) and interindividually between the different dose groups (Wilcoxon-Mann-Whitney U test). RESULTS: The strength level S4 showed the best conspicuity of infarcted areas. Compared with FBP, SAFIRE S4 statistically significantly (p < 0.01) reduced noise and improved CNRs without statistically significant differences in all subjective and objective criteria (p > 0.01) when the dose was reduced. Patients examined with a 260-mAs low-dose were exposed to a statistically significantly lower dose (1.77 vs 2.33 mSv; p < 0.01). CONCLUSION: Iterative reconstruction (SAFIRE at strength level S4) leads to increased subjective and objective image quality in CCT and allows dose reduction (-24%) without losses in the demarcation of ischemic lesions.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Segurança do Paciente , Doses de Radiação , Razão Sinal-Ruído
13.
Neuroradiology ; 57(6): 645-51, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25808122

RESUMO

INTRODUCTION: To investigate low-tube-voltage 80-kVp computed tomography (CT) of head and neck primary and recurrent squamous cell carcinoma (SCC) regarding objective and subjective image quality. METHODS: We retrospectively evaluated 65 patients (47 male, 18 female; mean age: 62.1 years) who underwent head and neck dual-energy CT (DECT) due to biopsy-proven primary (n = 50) or recurrent (n = 15) SCC. Eighty peak kilovoltage and standard blended 120-kVp images were compared. Attenuation and noise of malignancy and various soft tissue structures were measured. Tumor signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Subjective image quality was rated by three reviewers using 5-point grading scales regarding overall image quality, lesion delineation, image sharpness, and image noise. Radiation dose was assessed as CT dose index volume (CTDIvol). Interobserver agreement was calculated using intraclass correlation coefficient (ICC). RESULTS: Mean tumor attenuation (153.8 Hounsfield unit (HU) vs. 97.1 HU), SNR (10.7 vs. 8.3), CNR (8.1 vs. 4.8), and subjective tumor delineation (score, 4.46 vs. 4.13) were significantly increased (all P < 0.001) with 80-kVp acquisition compared to standard blended 120-kVp images. Noise of all measured structures was increased in 80-kVp acquisition (P < 0.001). Overall interobserver agreement was good (ICC, 0.86; 95 % confidence intervals: 0.82-0.89). CTDIvol was reduced by 48.7 % with 80-kVp acquisition compared to standard DECT (4.85 ± 0.51 vs. 9.94 ± 0.81 mGy cm, P < 0.001). CONCLUSIONS: Head and neck CT with low-tube-voltage 80-kVp acquisition provides increased tumor delineation, SNR, and CNR for CT imaging of primary and recurrent SCC compared to standard 120-kVp acquisition with an accompanying significant reduction of radiation exposure.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Recidiva Local de Neoplasia/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Doses de Radiação , Estudos Retrospectivos , Razão Sinal-Ruído , Adulto Jovem
14.
Age Ageing ; 44(4): 616-23, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25829392

RESUMO

BACKGROUND: excess weight is a risk factor for numerous co-morbidities that predominantly occur in later life. This study's purpose was to analyse the association between excess weight and health service use/costs in the older population in Germany. METHODS: this cross-sectional analysis used data of n = 3,108 individuals aged 58-82 from a population-based prospective cohort study. Body mass index (BMI) and waist-to-height ratio (WHtR) were calculated based on clinical examinations. Health service use was measured by a questionnaire for a 3-month period. Corresponding costs were calculated applying a societal perspective. RESULTS: 21.8% of the sample were normal weight, 43.0% overweight, 25.5% obese class 1 and 9.6% obese class ≥2 according to BMI. In 42.6%, WHtR was ≥0.6. For normal weight, overweight, obese class 1 and obese class ≥2 individuals, mean costs (3-month period) of outpatient care were 384€, 435€, 475€ and 525€ (P < 0.001), mean costs of inpatient care were 284€, 408€, 333€ and 652€ (P = 0.070) and mean total costs 716€, 891€, 852€ and 1,244€ (P = 0.013). For individuals with WHtR <0.6 versus ≥0.6, outpatient costs were 401€ versus 499€ (P < 0.001), inpatient costs 315€ versus 480€ (P = 0.016) and total costs 755€ versus 1,041€ (P < 0.001). Multiple regression analyses controlling for sociodemographic variables showed a significant effect of obesity on costs of outpatient care (class 1: +72€; class ≥2: +153€) and total costs (class ≥2: +361€) while the effect of overweight was not significant. WHtR ≥0.6 significantly increased outpatient costs by +79€ and total costs by +189€. CONCLUSIONS: excess weight is associated with increased service use and cost in elderly individuals, in particular in obese class ≥2 individuals.


Assuntos
Custos de Cuidados de Saúde , Serviços de Saúde/estatística & dados numéricos , Sobrepeso/epidemiologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Estudos Transversais , Feminino , Seguimentos , Alemanha/epidemiologia , Serviços de Saúde/economia , Humanos , Masculino , Pessoa de Meia-Idade , Morbidade/tendências , Sobrepeso/economia , Sobrepeso/prevenção & controle , Estudos Prospectivos , Fatores de Risco , Fatores de Tempo
15.
J Comput Assist Tomogr ; 39(2): 290-4, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25580679

RESUMO

Sliding-gantry computed tomography offers an interesting variety of treatment options for emergency radiology and clinical routine. The Frankfurt 2-room installation provides an interdisciplinary, multifunctional, and cost-effective concept. It is based on a magnetically sealed rail system for the permanent movement of the gantry between 2 adjacent rooms with fixed-mounted tables. In case of emergency or intensive care patients, routine scanning can be performed in room 1 until computed tomography diagnosis is required in room 2 and can then be continued in room 1 again. Moreover, this concept allows the simultaneous handling of 2 emergency patients.


Assuntos
Tomografia Computadorizada por Raios X/instrumentação , Desenho de Equipamento , Humanos
16.
BMC Geriatr ; 15: 83, 2015 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-26170016

RESUMO

BACKGROUND: Mean body weight gradually increases with age. Yet, little data exists on the prevalence of excess weight in populations aged 80 years or older. Moreover, little is known about predictors of overweight and obesity in old age. Thus, the purpose of this study was: To present data on the prevalence of excess weight in old age in Germany, to investigate predictors of excess weight in a cross-sectional approach and to examine factors affecting excess weight in a longitudinal approach. METHODS: Subjects consisted of 1,882 individuals aged 79 years or older. The course of excess weight was observed over 3 years. Excess weight was defined as follows: Overweight (25 kg/m(2) ≤ BMI < 30 kg/m(2)) and obesity (BMI ≥ 30 kg/m(2)). We used fixed effects regressions to estimate effects of time dependent variables on BMI, and overweight or obesity, respectively. RESULTS: The majority was overweight (40.0%) or obese (13.7%). Cross-sectional regressions revealed that BMI was positively associated with younger age, severe walking impairments and negatively associated with cognitive impairments. Excess weight was positively associated with younger age, elementary education, walking impairments and physical inactivity, while excess weight was negatively associated with cognitive impairment. Longitudinal regressions showed that age and severely impaired walking disabilities reduced BMI. The probability of transitions to excess weight decreased considerably with older age and occurrence of severe walking impairments (overweight). CONCLUSIONS: Marked differences between predictors in cross- and longitudinal setting exist, underlining the complex nature of excess weight in old age.


Assuntos
Transtornos Cognitivos , Cognição , Limitação da Mobilidade , Atividade Motora , Obesidade , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Causalidade , Transtornos Cognitivos/epidemiologia , Transtornos Cognitivos/fisiopatologia , Fatores de Confusão Epidemiológicos , Estudos Transversais , Feminino , Alemanha/epidemiologia , Humanos , Estudos Longitudinais , Masculino , Obesidade/diagnóstico , Obesidade/epidemiologia , Obesidade/fisiopatologia , Obesidade/psicologia , Prevalência , Índice de Gravidade de Doença , Fatores Socioeconômicos
17.
Radiol Med ; 120(12): 1112-21, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25981379

RESUMO

OBJECTIVES: To compare radiation exposure and image quality of second-generation 128-slice dual-source CT (DSCT) coronary angiography (cCTA) protocols. MATERIALS AND METHODS: We retrospectively analyzed data from four groups with 25 patients, each examined by one of the following DSCT cCTA protocols: prospectively ECG-gated high-pitch (group 1) or sequential (group 2) acquisition, retrospectively ECG-gated acquisition in dual-energy (DECT, group 3) or dual-source (group 4) mode. CT dose index volume, dose length product, estimated radiation dose, contrast-to-noise- and signal-to-noise-ratios were compared. Subjective image quality was rated by two observers blinded to the protocols. RESULTS: High-pitch DSCT showed a mean estimated radiation dose of 1.27 ± 0.62 mSv, significantly (p < 0.01) lower than sequential (2.04 ± 0.94 mSv), dual-energy (3.97 ± 1.29 mSv) or dual-source (8.11 ± 4.95 mSv) acquisition. Image noise showed no statistical difference (p > 0.91), ranging from 15.2 ± 4.4 (group 2) up to 24.5 ± 22.0 (group 4). Each protocol showed diagnostic image quality in at least 98.1 % of evaluated coronary segments without significant differences (p > 0.05). CONCLUSIONS: Prospectively ECG-gated DSCT protocols enable cCTA with significant dose reduction and consistently diagnostic image quality. In patients requiring retrospectively ECG-gated DSCT for functional analysis or due to arrhythmia, dual-energy mode should be preferred over dual-source mode as it significantly decreases estimated dose without compromising image quality.


Assuntos
Angiografia Coronária/métodos , Aumento da Imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Idoso , Humanos , Estudos Retrospectivos
18.
Radiol Med ; 120(7): 595-602, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25644250

RESUMO

PURPOSE: This study was done to investigate the dynamic changes of the aortic root during systole and diastole in patients with coronary artery calcification (CAC) using dual-source computed tomography (DSCT). MATERIALS AND METHODS: We retrospectively analysed 77 consecutive patients who underwent calcium-scoring and angiographic cardiac DSCT. The long- and short-axis dimensions, axis areas of the aortic annulus, sinotubular junction and ascending aorta at the level of the pulmonary trunk in diastole and systole were measured. Average dimensions and relative areal changes between diastole and systole (%RA) of aortic annulus, sinotubular junction and ascending aorta were compared. RESULTS: Systolic and diastolic long- and short-axis dimensions of the aortic annulus in patients with CAC (n = 44) demonstrated statistically significant differences (27.00 ± 2.84 mm vs. 28.04 ± 2.62 mm; P < 0.001; 21.78 ± 2.55 mm vs. 20.88 ± 2.31 mm; P < 0.001), while differences in average diameters and areas of the aortic annulus were nonsignificant (P > 0.586). Systolic and diastolic axial areas of the sinotubular junction in patients with CAC demonstrated significant differences (7.21 ± 1.80 cm(2) vs. 6.92 ± 1.75 cm(2); P < 0.001). The %RA of the ascending aorta in patients with severe CAC (CAC score >400; n = 15) was significantly reduced compared to patients with minimal-to-moderate CAC (CAC score <400; n = 29; 4.77 ± 2.88 vs. 7.51 ± 3.81, P = 0.014). CONCLUSIONS: In comparison with patients without CAC, the long- and short-axis dimensions of the aortic annulus and areas of the sinotubular junction show significant differences during the cardiac cycle in patients with CAC. The presence of severe CAC significantly influences the flexibility of the wall of the ascending aorta.


Assuntos
Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Diástole , Sístole , Tomografia Computadorizada por Raios X , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
19.
Anal Chem ; 86(16): 8213-23, 2014 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-25072276

RESUMO

We describe the concept of magnetic particle-scanning for on-chip detection of biomolecules: a magnetic particle, carrying a low number of antigens (Ag's) (down to a single molecule), is transported by hydrodynamic forces and is subjected to successive stochastic reorientations in an engineered magnetic energy landscape. The latter consists of a pattern of substrate-bound small magnetic particles that are functionalized with antibodies (Ab's). Subsequationuent counting of the captured Ag-carrying particles provides the detection signal. The magnetic particle-scanning principle is investigated in a custom-built magneto-microfluidic chip and theoretically described by a random walk-based model, in which the trajectory of the contact point between an Ag-carrying particle and the small magnetic particle pattern is described by stochastic moves over the surface of the mobile particle, until this point coincides with the position of an Ag, resulting in the binding of the particle. This model explains the particular behavior of previously reported experimental dose-response curves obtained for two different ligand-receptor systems (biotin/streptavidin and TNF-α) over a wide range of concentrations. Our model shows that magnetic particle-scanning results in a very high probability of immunocomplex formation for very low Ag concentrations, leading to an extremely low limit of detection, down to the single molecule-per-particle level. When compared to other types of magnetic particle-based surface coverage assays, our strategy was found to offer a wider dynamic range (>8 orders of magnitude), as the system does not saturate for concentrations as high as 10(11) Ag molecules in a 5 µL drop. Furthermore, by emphasizing the importance of maximizing the encounter probability between the Ag and the Ab to improve sensitivity, our model also contributes to explaining the behavior of other particle-based heterogeneous immunoassays.


Assuntos
Anticorpos Imobilizados/química , Imunoensaio/instrumentação , Magnetismo/instrumentação , Imãs/química , Técnicas Analíticas Microfluídicas/instrumentação , Prata/química , Animais , Biotina/química , Bovinos , Desenho de Equipamento , Fenômenos Magnéticos , Camundongos , Modelos Químicos , Estreptavidina/análise , Fator de Necrose Tumoral alfa/sangue
20.
Radiology ; 271(3): 778-84, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24475863

RESUMO

PURPOSE: To evaluate the feasibility of phantomless in vivo dual-energy computed tomography (CT)-based three-dimensional (3D) bone mineral density (BMD) assessment in comparison with dual x-ray absorptiometry (DXA). MATERIALS AND METHODS: This retrospective study was approved by the institutional review board, and the requirement to obtain informed consent was waived. Data from clinically indicated dual-energy CT and DXA examinations within 2 months, comprising the lumbar spine of 40 patients, were included. By using automated dedicated postprocessing dual-energy CT software, the trabecular bone of lumbar vertebrae L1-L4 were analyzed and segmented. A mixed-effects model was used to assess the correlations between BMD values derived from dual-energy CT and DXA. RESULTS: One hundred sixty lumbar vertebrae were analyzed in 40 patients (mean age, 57.1 years; range, 24-85 years), 21 male (mean age, 54.3 years; range, 24-85 years) and 19 female (mean age, 58.5 years; range, 31-80 years). Mean BMD of L1-L4 determined with DXA was 0.995 g/cm(2), and 18 patients (45%) showed an osteoporotic BMD (T score less than -2.5) of at least two vertebrae. Mean dual-energy CT-based BMD of L1-L4 was 0.254 g/cm(3). Bland-Altman analysis with mixed effects demonstrated a lack of correlation between dual-energy CT-based and DXA-based BMD values, with a mean difference of 0.7441 and 95% limits of agreement of 0.7441 ± 0.4080. CONCLUSION: Dedicated postprocessing of dual-energy CT data allows for phantomless in vivo BMD assessment of the trabecular bone of lumbar vertebrae and enables freely rotatable color-coded 3D visualization of intravertebral BMD distribution.


Assuntos
Densidade Óssea , Doenças Ósseas Metabólicas/diagnóstico por imagem , Imageamento Tridimensional , Vértebras Lombares/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Absorciometria de Fóton , Adulto , Idoso , Idoso de 80 Anos ou mais , Doenças Ósseas Metabólicas/patologia , Feminino , Humanos , Vértebras Lombares/patologia , Masculino , Pessoa de Meia-Idade , Osteoporose/patologia , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA