RESUMO
AIM: Lower gastrointestinal (GI) diagnostics have been facing relentless capacity constraints for many years, even before the COVID-19 era. Restrictions from the COVID pandemic have resulted in a significant backlog in lower GI diagnostics. Given recent developments in deep neural networks (DNNs) and the application of artificial intelligence (AI) in endoscopy, automating capsule video analysis is now within reach. Comparable to the efficiency and accuracy of AI applications in small bowel capsule endoscopy, AI in colon capsule analysis will also improve the efficiency of video reading and address the relentless demand on lower GI services. The aim of the CESCAIL study is to determine the feasibility, accuracy and productivity of AI-enabled analysis tools (AiSPEED) for polyp detection compared with the 'gold standard': a conventional care pathway with clinician analysis. METHOD: This multi-centre, diagnostic accuracy study aims to recruit 674 participants retrospectively and prospectively from centres conducting colon capsule endoscopy (CCE) as part of their standard care pathway. After the study participants have undergone CCE, the colon capsule videos will be uploaded onto two different pathways: AI-enabled video analysis and the gold standard conventional clinician analysis pathway. The reports generated from both pathways will be compared for accuracy (sensitivity and specificity). The reading time can only be compared in the prospective cohort. In addition to validating the AI tool, this study will also provide observational data concerning its use to assess the pathway execution in real-world performance. RESULTS: The study is currently recruiting participants at multiple centres within the United Kingdom and is at the stage of collecting data. CONCLUSION: This standard diagnostic accuracy study carries no additional risk to patients as it does not affect the standard care pathway, and hence patient care remains unaffected.
Assuntos
COVID-19 , Endoscopia por Cápsula , Pólipos do Colo , Humanos , Pólipos do Colo/diagnóstico , Endoscopia por Cápsula/métodos , Inteligência Artificial , Estudos Prospectivos , Estudos Retrospectivos , COVID-19/diagnósticoRESUMO
Background: Capsule endoscopy (CE) is safe and widely accepted for small bowel (SB) investigation and an alternative to colonoscopy in specific clinical circumstances. As the capsule is orally ingested, the potential risk of aspiration is undoubtedly a constant concern among clinicians. However, it is a rare occurrence and often reported as isolated cases. Therefore, this review systematically compiles all the available data on capsule aspiration in the literature with an aim to provide an update on this complication of CE. Methods: A systematic literature search was performed on PubMed with the search terms 'capsule endoscopy' AND 'aspiration', searched as keywords and MeSH. All observational cohort studies that reported aspiration among complications/outcomes, case reports and series on capsule aspiration were included. Manual citation search was performed. Two extractors reviewed abstract and full-text and performed data extraction. Results: We found 95 relevant articles, and cross-checking references led to the inclusion of an additional 19 articles. We removed 57 and ended with 57 references-with 63 cases of aspirated capsules. One death was reported. The median age was 78, and there was male preponderance. The most common indication for CE was anaemia, and only aspiration of small bowel CE (SBCE) was reported. 61.9% of the aspirations were symptomatic; the most common symptom was coughing. 69.8% of capsules ended in the bronchus, but only 4 cases experienced desaturation. Thirty-two patients needed intervention for retrieval; the aspiration was self-resolved in the remaining. Only four patients had a history of dysphagia. Thirteen instances of aspiration were detected due to real-time viewing, and 24 cases from reviewing the capsule data afterwards. Conclusions: With only 63 cases of aspirated capsules reported in the literature, this event remains rare, is safely managed, and should not discourage patients from the procedure. The importance of careful patient selection is crucial to minimize the likelihood of aspiration and capsule administration should be approached with precautions.
RESUMO
Background and study aims This review aimed to provide an updated and comprehensive review of capsule retention within diverticula, shedding light on the characteristics and management of this rare event in capsule endoscopy. Methods A systematic literature search was conducted across multiple databases. All observational studies that reported capsule retention in a diverticulum among complication and outcomes, as well as case reports and series, were included. Manual cross-checking of references was also performed. Two extractors performed abstract and full-text reviews, as well as data-extraction. Results We found 167 references from Pubmed, Embase, and Web Of Science. Sixty-five duplicates were removed and another 71 references were excluded. Crosschecking of references found additional two articles. In total, 32 articles were included, resulting in a total of 34 cases of retained capsules in diverticula. The median age was 69 and the majority of the patients were male (76.5%). The most common retention occurred in Meckel's diverticulum (32.4%) followed by Zenker's diverticulum (20.6%). Investigation of capsule retention was done with x-ray (50%) and computed tomography (CT) scan (44.1%). Seventeen cases (50%) were asymptomatic. Resolution of the retention happened with endoscopy (35.3%) and surgical management (32.4%), as well as self-resolution (20.6%). Conclusions Due to the small number of cases, diverticula are not a risk factor for incomplete capsule endoscopy examination. It affects mainly elderly, male, asymptomatic patients, and typically is diagnosed with x-rays and CT scans. The most common type is Meckel's diverticulum, and endoscopy is the primary management. Capsule endoscopy retentions are extremely rare, with only 34 cases reported since the technology's introduction.
RESUMO
Colon capsule endoscopy (CCE) has regained popularity for lower gastrointestinal investigations since the COVID-19 pandemic. While there have been systematic reviews and meta-analyses on colonic polyp detection using CCE, there is a lack of comprehensive evidence concerning colonic inflammation. Therefore, this systematic review and meta-analysis aimed to assess the diagnostic accuracy of CCE for colonic inflammation, predominantly ulcerative colitis (UC) and Crohn's disease (CD). Methods: We systematically searched electronic databases (EMBASE, MEDLINE, PubMed Central, and Cochrane Library) for studies comparing the diagnostic accuracy between CCE and optical endoscopy as the standard reference. A bivariate random effect model was used for the meta-analysis. Results: From 3797 publications, 23 studies involving 1353 patients were included. Nine studies focused on UC, and ten focused on CD. For UC, CCE showed a pooled sensitivity of 92% (95% CI, 88-95%), a specificity of 71% (95% CI, 35-92%), and an AUC of 0.93 (95% CI, 0.89-0.97). For CD, the pooled sensitivity was 92% (95% CI, 89-95%), and the specificity was 88% (95% CI, 84-92%), with an AUC of 0.87 (95% CI, 0.76-0.98). Overall, for inflammatory bowel disease, the pooled sensitivity, specificity, and AUC were 90% (95% CI, 85-93%), 76% (95% CI, 56-90%), and 0.92 (95% CI, 0.94-0.97), respectively. Conclusions: Despite the challenges around standardised disease scoring and the lack of histological confirmation, CCE performs well in diagnosing inflammatory bowel disease. It demonstrates high sensitivity in both UC and Crohn's terminal ileitis and colitis and high specificity in Crohn's disease. Further studies are needed to evaluate the diagnostic accuracy of other colonic inflammatory conditions.
RESUMO
Background: Colon capsule endoscopy (CCE) has gained momentum as an alternative modality for the investigation of the lower gastrointestinal tract. Of the few challenges that remain, the comparison and - eventually - matching of polyps at different timestamps leads to the potential for double reporting and can contribute to false-positive findings and inaccuracies. With the impending artificial intelligence integration, the risk of double reporting the same polyp due to the lack of information on spatial orientation underscores the necessity for establishing criteria for polyp matching. Objectives: This RAND/University of California, Los Angeles (modified Delphi) process aims to identify the key factors or components used to match polyps within a CCE video. This involves exploring the attributes of each factor to create comprehensive polyp-matching criteria based on international expert consensus. Design: A systematic qualitative study using surveys. Methods: A panel of 11 international CCE experts convened to assess a survey comprised of 60 statements. Participants anonymously rated statement appropriateness on a 1-9 scale (1-3: inappropriate, 4-6: uncertain and 7-9: appropriate). Following a virtual group discussion of the Round 1 results, a Round 2 survey was developed and completed before the final analysis. Results: The factors that were agreed to be essential for polyp matching include (1) timestamp, (2) polyp localization, (3) polyp vascular pattern, (4) polyp size, (5) time interval of the polyp appearance between the green and yellow camera, (6) surrounding tissue, (7) polyp morphology and (8) polyp surface and contour. When five or more factors are satisfied, it was agreed that the comparing polyps are likely the same polyp. Conclusion: This study has established the first complete criteria for polyp matching in CCE. While it might not provide a definitive solution for matching difficult, small and common polyps, these criteria serve as a framework to guide and facilitate the process of polyp-matching.
Creating criteria and standards for matching polyps (abnormal growth in the bowels) on colon capsule video analysis: an international expert agreement using the RAND (modified Delphi process) process Background: Doctors often use colon capsule endoscopy (CCE), a high-tech capsule with two cameras, to record and check for diseases in the small and large bowels as the capsule travels through the intestines. One of the most common conditions in the large bowel is polyps, which are abnormal growths in the lining of the bowel. Comparing and matching polyps in the same video from the capsule can be tricky as they look very similar, leading to the possibility of incorrectly reporting the same polyp twice or more. This can lead to wrong results and inaccuracies. The literature did not have any criteria or standards for matching polyps in CCE before. Aim: Using the RAND/UCLA (modified Delphi) process, this study aims to identify the key factors or components used to match polyps within a CCE video. The goal is to explore each factor and create complete criteria for polyp matching based on the agreement from international experts. Method: A group of 11 international CCE experts came together to evaluate a survey with 60 statements. They anonymously rated each statement on a scale from 1 to 9 (1-3: inappropriate, 4-6: uncertain, and 7-9: appropriate). After discussing the Round 1 results virtually, a Round 2 survey with the same but revised questions was created and completed before the final analysis of their agreement. Results: The main factors for matching polyps are 1) the timing when the polyp was seen, 2) where it is in the bowel, 3) its blood vessel pattern, 4) size, 5) the timing of its appearance between cameras, 6) surrounding tissue features, 7) its shape, and 8) surface features. If five or more of these factors match, the compared polyps are likely the same. Conclusion: This study establishes the first complete criteria for matching polyps in CCE. While it may not provide a definitive solution for matching challenging and small polyps, these criteria serve as a guide to help and make the process of polyp matching easier.
RESUMO
BACKGROUND: Lateral flow tests (LFT) are point-of-care rapid antigen tests that allow isolation and control of disease outbreaks through convenient, practical testing. However, studies have shown significant variation in their diagnostic accuracy. We conducted a systematic review of the diagnostic accuracy of LFTs for the detection of severe acute respiratory syndrome-coronavirus 2 (SARS-CoV-2) to identify potential factors affecting their performance. METHODS: A systematic search of online databases was carried out to identify studies assessing the sensitivity and specificity of LFTs compared with polymerase chain reaction (PCR) tests. Data were extracted and used to calculate pooled sensitivity and specificity. Meta-regression analysis was conducted to identify covariates influencing diagnostic accuracy. RESULTS: In total, 76 articles with 108,820 test results were identified for analysis. Pooled sensitivity and specificity were 72% (95% confidence interval (CI): 0.68-0.76) and 100% (95% CI: 0.99-1.00), respectively. Staff operation of the LFT showed a statistically significant increase in sensitivity (p=0.04) and specificity (p=0.001) compared with self-operation by the test subjects. The use of LFTs in symptomatic patient subgroups also resulted in higher test sensitivity. CONCLUSION: LFTs display good sensitivity and extremely good specificity for SARS-CoV-2 antigen detection; they become more sensitive in patients with symptoms and when performed by trained professionals.