Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Knee Surg Sports Traumatol Arthrosc ; 25(4): 1184-1190, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26239862

RESUMO

PURPOSE: Dynamic intraligamentary stabilization (DIS) has been introduced for the repair of acute anterior cruciate ligament (ACL) tears as an alternative to delayed reconstruction. The aim of the present study was to compare knee joint kinematics after DIS to those of the ACL-intact and ACL-deficient knee under simulated Lachman/KT-1000 and pivot-shift tests. We hypothesized that DIS provides knee joint kinematics equivalent to an intact ACL. METHODS: With the use of a robotic knee simulator, knee kinematics were determined in simulated Lachman/KT-1000 and pivot-shift tests at 0°, 15°, 30°, 60°, and 90° of flexion in eight cadaveric knees under the following conditions: (1) intact ACL, (2) ACL deficiency, (3) DIS with a preload of 60 N, and (4) DIS with a preload of 80 N. Statistical analyses were performed using two-factor repeated-measures analysis of variance. The significance level was set at a p value of <0.05. RESULTS: After DIS with a preload of either 60 N or 80 N, the anterior translation was significantly reduced in the simulated Lachman/KT-1000 and pivot-shift tests when compared to the ACL-deficient knee (p < 0.05). No significant differences were observed between the DIS reconstruction with a preload of 80 N and the intact ACL with regard to anterior laxity in either test. However, DIS with a preload of only 60 N was not able to restore knee joint kinematics to that of an intact knee in all degrees of flexion. CONCLUSION: DIS with a preload of 80 N restores knee joint kinematics comparable to that of an ACL-intact knee and is therefore capable of providing knee joint stability during ACL healing. DIS therefore provides a new technique for primary ACL repair with superior biomechanical properties in comparison with other techniques that have been described previously, although further clinical studies are required to determine its usefulness in clinical settings.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Articulação do Joelho/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos/fisiologia , Cadáver , Humanos , Instabilidade Articular/fisiopatologia , Instabilidade Articular/cirurgia , Articulação do Joelho/cirurgia , Pessoa de Meia-Idade , Exame Físico/métodos
2.
Arch Orthop Trauma Surg ; 137(12): 1693-1698, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28929365

RESUMO

OBJECTIVES: The surgical treatment of comminuted fractures of the distal humerus remains a challenging problem. The aim of the present study was to compare the clinical outcomes of primary external fixation with second-staged open reduction and internal fixation (ORIF) and initial definitive internal fixation in surgically treated patients with comminuted distal humerus fractures. DESIGN: Retrospective comparative study. SETTING: Level one trauma center. PATIENTS: A total of 24 patients (median age 52 years; range 14-84 years) were included: 15 patients were treated with initial definitive internal fixation with pre-contoured locking compression plates (group A), and 9 patients underwent surgical treatment with primary external fixation and second-staged ORIF (group B). Only patients with C3 fractures according to the AO classification were included in the study. MAIN OUTCOME MEASUREMENT: Disability of the Arm, Shoulder and Hand (DASH) and Mayo Elbow Performance Score (MEPS). INTERVENTION: External fixation internal fixation with locking plates. RESULTS: The median follow-up was 37 months for both groups. There was a significantly higher median elbow extension deficit in group B (39°) compared to group A (17°) (p = 0.048). The mean DASH score in group A was 14 and 12.5 in group B. MEPS showed that more patients in group A achieved excellent results; however, there was no significant difference compared to group B. CONCLUSIONS: Primary external fixation with second-staged ORIF demonstrated a higher complication rate and significantly greater loss of extension compared with initial definitive internal fixation. Thus, the use of primary external fixation in cases of comminuted distal humerus fractures appears to have a negative influence on the patient outcomes. LEVEL OF EVIDENCE: Therapeutic level III.


Assuntos
Fixadores Externos , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/cirurgia , Fraturas do Úmero/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Placas Ósseas , Articulação do Cotovelo/cirurgia , Fixadores Externos/efeitos adversos , Feminino , Seguimentos , Fixação Interna de Fraturas/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Redução Aberta , Complicações Pós-Operatórias , Reoperação , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
3.
Arthroscopy ; 32(1): 78-89, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26372523

RESUMO

PURPOSE: To kinematically and biomechanically compare 4 different types of tibial tunnel management in single-stage anterior cruciate ligament (ACL) revision reconstruction with the control: primary ACL reconstruction using a robotic-based knee testing setup. METHODS: Porcine knees and flexor tendons were used. One hundred specimens were randomly assigned to 5 testing groups: (1) open tibial tunnel, (2) bone plug technique, (3) biodegradable interference screw, (4) dilatation technique, and (5) primary ACL reconstruction. A robotic/universal force-moment sensor testing system was used to simulate the KT-1000 (MEDmetric, San Diego, CA) and pivot-shift tests. Cyclic loading and load-to-failure testing were performed. RESULTS: Anterior tibial translation increased significantly with all of the techniques compared with the intact ACL (P < .05). In the simulated KT-1000 test, groups 2 and 3 achieved results equal to those of primary ACL reconstruction (P > .05). The open tunnel and dilated tunnel techniques showed significantly greater anterior tibial translation (P < .05). The results of the simulated pivot-shift test were in accordance with those of the KT-1000 test. No significant differences could be observed regarding stiffness or maximum load to failure. However, elongation was significantly lower in the primary ACL reconstruction group compared with groups 1 and 3 (P = .02 and P = .03, respectively). CONCLUSIONS: Filling an incomplete and incorrect tibial tunnel with a press-fit bone plug or a biodegradable interference screw in a standardized laboratory situation provided initial biomechanical properties and knee stability comparable with those of primary ACL reconstruction. In contrast, the dilatation technique or leaving the malplaced tunnel open did not restore knee kinematics adequately in this model. Backup extracortical fixation should be considered because the load to failure depends on the extracortical fixation when an undersized interference screw is used for aperture fixation. CLINICAL RELEVANCE: Our biomechanical results could help orthopaedic surgeons to optimize the results of primary ACL revision with incomplete, incorrect tunnel placement.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Ligamento Cruzado Anterior/cirurgia , Amplitude de Movimento Articular , Tíbia/cirurgia , Animais , Fenômenos Biomecânicos , Parafusos Ósseos , Articulação do Joelho/cirurgia , Reoperação , Robótica , Suínos , Tendões/cirurgia
4.
Int Orthop ; 40(8): 1717-1723, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26432575

RESUMO

PURPOSE: The aim of this study was to biomechanically assess patellar tendon repair techniques with additional cable wire or polydioxanone suture (PDS) cord augmentation in comparison with a suture-anchor repair technique. METHODS: Patellar tendon repair was performed in 60 specimens using a porcine bone model. Yield load, maximum load, stiffness and elongation of patellar tendon reconstructions with (1) cable wire augmentation, (2) PDS cord augmentation or (3) suture anchor repair were evaluated using a cyclic loading and load-to-failure test setup. RESULTS: In comparison with suture anchor repair, augmentation of the reconstruction with either cable wires or PDS cords provides significantly higher maximum loads (527 and 460 N vs. 301 N; p < 0.01 and p = 0,012, respectively) under load-to-failure testing and less elongation (8.81 mm ± 1.55 mm and 10.56 mm ± 3.1 mm vs. 18.38 mm ± 7.51 mm; p = 0.037 and p = 0.033, respectively) under cyclic loading conditions. CONCLUSION: Augmentation of a patellar tendon repair with either a cable wire or a PDS cord provides higher primary stability than suture anchor repair in patellar tendon ruptures. The study supports the use of additional augmentation of a tendon repair in the clinical setting in order to prevent loss of reduction and allow for early post-operative mobilisation.


Assuntos
Traumatismos do Joelho/cirurgia , Patela/cirurgia , Ligamento Patelar/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Animais , Fenômenos Biomecânicos , Deambulação Precoce , Humanos , Período Pós-Operatório , Âncoras de Sutura , Técnicas de Sutura , Suturas , Suínos , Traumatismos dos Tendões/cirurgia
5.
Acta Orthop Belg ; 80(1): 106-11, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24873093

RESUMO

Aim of the present study was to compare the clinical and radiographic outcome of tension band wiring and precontoured locking compression plate fixation in patients treated surgically for an isolated olecranon fractures type IIA according to the Mayo classification. Of 26 patients presenting with an isolated Mayo type IIA olecranon fracture, 13 underwent fixation with a precontoured locking compression plate (group A), 13 patients were treated with tension band wiring (group B). At a mean follow-up of 43 months, patients were clinically and radiographically re-examined using the DASH score, the Mayo Elbow Performance score (MEPS) and anteroposterior and lateral radiographs. The mean DASH score was 14 points in group A and 12.5 points in group B. Regarding the MEPS, 92% of the patients in group A achieved a good to excellent results in comparison to 77% in group B. No significant differences between the two groups could be detected regarding the clinical and radiographic outcome. Implant-related irritations requiring hardware removal occurred more frequently in group B (12 vs. 7). Procedure and implant related costs were significantly higher in group A. Tension band wiring is still a preferable surgical method to treat simple isolated olecranon fractures. The patient must be informed that in all likelihood implant removal will be required once the fracture has healed. Fixation with precontoured locking compression plates does not provide better functional and radiographic outcome but is more expensive than tension band wiring.


Assuntos
Placas Ósseas , Fios Ortopédicos , Olécrano/lesões , Fraturas da Ulna/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Olécrano/diagnóstico por imagem , Complicações Pós-Operatórias , Radiografia , Reoperação , Fraturas da Ulna/diagnóstico por imagem
6.
Arthroscopy ; 29(4): 766-73, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23395115

RESUMO

PURPOSE: To compare the structural properties of 5 different fixation strategies for a free tendon graft at the patella in medial patellofemoral ligament (MPFL) reconstruction under cyclic loading and load to failure testing. METHODS: We used porcine patella and flexor tendons. We tested the following fixation techniques: 3.5-mm titanium anchor, transosseous 1-mm braided polyester suture, interference screw fixation, medial bone bridge, and transpatellar tunnels. We preconditioned each graft between 5 and 20 Nm before cyclic loading with 100 Nm for 1,000 cycles was started, and then performed load to failure testing. We recorded maximum load, stiffness, and elongation. RESULTS: In the bone bridge group, 60% of all specimens failed during cyclic testing. Fixation by transosseous sutures showed significantly less stiffness compared with all other techniques (P < .05). The bone bridge technique showed significantly lower load to failure compared with all other techniques (P < .05). Differences between the other groups were not significant. CONCLUSIONS: Fixation of a free tendon graft by transosseous sutures provides similar load to failure and elongation but less stiffness compared with fixation by anchors, interference screws, or transverse tunnels. Load to failure for the bone bridge technique was significantly lower than that for all other techniques. Furthermore, this fixation technique had a lower load to failure than that of the native MPFL. CLINICAL RELEVANCE: Fixation of soft tissue grafts at the patella by 1-mm braided polyester suture provides adequate fixation strength without implants in the patella, which might cause soft tissue irritation. Further studies will have to show if the lesser stiffness of this technique causes problems in the clinical setting or if this laxity might even be an advantage because it makes this reconstruction more forgiving concerning overtensioning the graft. Significantly lower load to failure of the bone bridge technique should be considered in postoperative treatment.


Assuntos
Ligamentos Articulares/cirurgia , Patela/cirurgia , Articulação Patelofemoral/lesões , Articulação Patelofemoral/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Tendões/transplante , Animais , Fenômenos Biomecânicos , Ligamentos Articulares/lesões , Modelos Animais , Técnicas de Sutura , Suínos , Tendões/fisiopatologia
7.
Knee Surg Sports Traumatol Arthrosc ; 21(5): 1176-82, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22552620

RESUMO

PURPOSE: To evaluate the biomechanical properties of a new coracoclavicular (CC) ligament reconstruction using a subcoracoidal flip button and a tendon graft compared to an augmented tendon loop and a synthetic coracoclavicular ligament reconstruction. METHODS: A porcine metatarsalia model was used to assess supero-inferior fixation strength of (1) a new technique using an augmented tendon graft and a subcoracoidal flip button in a lifting block fashion, (2) an augmented tendon loop around the coracoid base and (3) a synthetic coracoclavicular ligament augmentation technique. Cyclic loading from 20 to 70 N for 1,000 cycles was performed, followed by a load-to-failure protocol. RESULTS: All specimens of the three different groups survived the cyclic loading protocol. The maximum loads to failure under superior loading conditions were 760 ± 78 N for group 1, 702 ± 48 N for group 2 and 1117 ± 91 N for group 3. The synthetic coracoclavicular ligament augmentation technique revealed significantly higher maximum loads compared to the other groups (p < 0.001). The augmented tendon graft/flip button construct had higher maximum loads than the augmented tendon loop (n.s.). No significant differences were found for stiffness and elongation behaviour among the 3 tested groups. CONCLUSION: The results suggest that the described technique is an alternative option to reconstruct the CC ligaments in AC joint instability in a minimal-invasive technique. Under superior loading conditions, the biomechanical properties exhibited by this novel technique were comparable to those of the tendon loop around the coracoid base.


Assuntos
Articulação Acromioclavicular/lesões , Luxações Articulares/cirurgia , Ligamentos Articulares/cirurgia , Procedimentos de Cirurgia Plástica , Animais , Fenômenos Biomecânicos , Modelos Animais de Doenças , Ligamentos Articulares/fisiopatologia , Procedimentos Cirúrgicos Minimamente Invasivos , Suínos , Tendões/transplante
8.
Knee Surg Sports Traumatol Arthrosc ; 18(11): 1551-8, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20461359

RESUMO

To evaluate the influence of tibial and femoral tunnel position in ACL reconstruction on knee kinematics, we compared ACL reconstruction with a tibial and femoral tunnel in anteromedial (AM-AM reconstruction) and in posterolateral footprint (PL-PL reconstruction) with a reconstruction technique with tibial posterolateral and femoral anteromedial tunnel placement (PL-AM reconstruction). In 9 fresh-frozen human cadaveric knees, the knee kinematics under simulated Lachman (134 N anterior tibial load) and a simulated pivot shift test (10 N/m valgus and 4 N/m internal tibial torque) were determined at 0°, 30°, 60°, and 90° of flexion. Kinematics were recorded for intact, ACL-deficient, and single-bundle ACL reconstructed knees using three different reconstruction strategies in randomized order: (1) PL-AM, (2) AM-AM and (3) PL-PL reconstructions. Under simulated Lachman test, single-bundle PL-AM reconstruction and PL-PL reconstructions both showed significantly increased anterior tibial translation (ATT) at 60° and 90° when compared to the intact knee. At all flexion angles, AM-AM reconstruction did not show any statistical significant differences in ATT compared to the intact knee. Under simulated pivot shift, PL-AM reconstruction resulted in significantly higher ATT at 0°, 30°, and 60° knee flexion and AM-AM reconstructions showed significantly higher ATT at 30° compared to the intact knee. PL-PL reconstructions did not show any significant differences to the intact knee. AM-AM reconstructions restore the intact knee kinematics more closely when compared to a PL-AM technique resembling a transtibial approach. PL-PL reconstructions showed increased ATT at higher flexion angles, however, secured the rotational stability at all flexion angles. Due to the independent tibial and femoral tunnel location, a medial portal technique may be superior to a transtibial approach.


Assuntos
Ligamento Cruzado Anterior/cirurgia , Articulação do Joelho/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Estresse Mecânico , Idoso , Fenômenos Biomecânicos , Cadáver , Feminino , Fêmur/cirurgia , Humanos , Instabilidade Articular/prevenção & controle , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Resistência à Tração , Tíbia/cirurgia
9.
Am J Sports Med ; 34(3): 456-63, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16303880

RESUMO

BACKGROUND: Previous studies have identified the femoral attachment of the posterior cruciate ligament fibers as one of the primary determinants of fiber tension behavior. In addition, a double-bundle posterior cruciate ligament reconstruction has been shown to restore the intact knee kinematics more closely than does a single-bundle reconstruction. HYPOTHESIS: An anterior tunnel position in double-bundle posterior cruciate ligament reconstruction restores the biomechanics of the normal knee more closely than does a posterior tunnel position. STUDY DESIGN: Controlled laboratory study. METHODS: Kinematics and in situ forces of human knees after double-bundle posterior cruciate ligament reconstruction with 2 different femoral tunnel positions (anterior vs posterior) were evaluated using a robotic/universal force-moment sensor testing system. Within the same specimen, the resulting knee kinematics and in situ forces were compared. For statistical analysis, 2-way analysis of variance repeated measures were performed. RESULTS: The femoral tunnel position of the double-bundle hamstring graft had significant effect on the resulting posterior tibial displacement and in situ forces of the hamstring grafts. The anterior femoral tunnel position provided significantly less posterior tibial translation than did the posterior tunnel position. There was a tendency toward higher in situ forces of grafts fixed in the anterior tunnel when compared to the posterior position, but this difference was statistically not significant. CONCLUSION: An anterior position of the bone tunnels in double-bundle posterior cruciate ligament reconstruction restores the normal knee kinematics more closely than does a posterior position of the tunnels. CLINICAL RELEVANCE: In double-bundle posterior cruciate ligament reconstruction, posterior placement of the tunnel should be avoided.


Assuntos
Articulação do Joelho/cirurgia , Ligamento Cruzado Posterior/cirurgia , Robótica/instrumentação , Idoso , Fenômenos Biomecânicos , Cadáver , Alemanha , Humanos , Articulação do Joelho/fisiopatologia , Pessoa de Meia-Idade , Ligamento Cruzado Posterior/fisiopatologia , Procedimentos de Cirurgia Plástica/instrumentação
10.
Am J Sports Med ; 44(1): 126-32, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26574601

RESUMO

BACKGROUND: Anatomic femoral tunnel placement in anterior cruciate ligament (ACL) reconstruction is considered to be a key to good primary stability of the knee. There is still no consensus on whether a centrally placed single bundle in the anatomical femoral footprint can compare with anatomic double-bundle (DB) reconstruction. PURPOSE/HYPOTHESIS: The purpose of this study was to determine knee kinematics after single-bundle ACL reconstruction via the medial portal technique using 2 different femoral tunnel positions and to compare results with those of the anatomic DB technique. The hypotheses were that (1) single-bundle reconstruction using the medial portal technique with a centrally placed femoral tunnel relative to the native footprint (SB-central technique) would more closely restore intact knee kinematics compared with the same reconstruction technique with an eccentric femoral tunnel drilled in the anteromedial bundle footprint (SB-AM technique) and (2) DB reconstruction would result in superior kinematics compared with the SB-central technique. STUDY DESIGN: Controlled laboratory study. METHODS: Knee kinematics was examined in 10 fresh-frozen human cadaveric knees using a robotic/universal force-moment sensor system. Kinematics in simulated pivot-shift and 134-N anterior tibial loading tests were determined in different conditions within the same specimen: (1) intact ACL, (2) deficient ACL, (3) SB-AM, (4) SB-central, and (5) DB. RESULTS: All reconstruction techniques significantly reduced anterior tibial translation (ATT) compared with a deficient ACL at 0°, 15°, 30°, 60°, and 90° in the anterior tibial loading test (P < .01, repeated-measures analysis of variance) and at 0°, 15°, and 30° in the simulated pivot-shift test (P < .001). There were no significant differences in the SB-central group and the DB group compared with the intact ACL. Reconstruction in the SB-AM group resulted in significantly increased ATT compared with the intact ACL in near-to-extension angles in both tests (0°, 15°, and 30°; P < .01). SB-central and DB reconstructions both resulted in significantly reduced ATT, in some tests at ≤30°, compared with SB-AM reconstruction (P < .05). No significant differences between the SB-central and DB groups were found (P > .05). CONCLUSION: The SB-central technique restored intact knee kinematics more closely than did SB-AM reconstruction at time zero. There were no differences in knee kinematics between the DB and SB-central techniques. CLINICAL RELEVANCE: Anatomic single-bundle ACL reconstruction provides similar knee kinematics as anatomic double-bundle reconstruction.


Assuntos
Reconstrução do Ligamento Cruzado Anterior/métodos , Fêmur/cirurgia , Articulação do Joelho/fisiologia , Articulação do Joelho/cirurgia , Idoso , Idoso de 80 Anos ou mais , Ligamento Cruzado Anterior/cirurgia , Fenômenos Biomecânicos , Cadáver , Fêmur/fisiologia , Humanos , Pessoa de Meia-Idade , Tíbia/fisiologia , Tíbia/cirurgia
11.
Knee ; 21(6): 1169-74, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25178693

RESUMO

BACKGROUND: The aim of this study was to analyze the structural properties of the original MPFL and to compare it to a MPFL-reconstruction-technique using a strip of quadriceps tendon. METHODS: In 13 human cadaver knees the MPFLs were dissected protecting their insertion at the patellar border. The MPFL was loaded to failure after preconditioning with 10 cycles in a uniaxial testing machine evaluating stiffness, yield load and maximum load to failure. In the second part Quadriceps-MPFL-reconstruction was performed and tested in a uniaxial testing machine. Following preconditioning, the constructs were cyclically loaded 1000 times between 5 and 50 N measuring the maximum elongation. After cyclic testing, the constructs have been loaded to failure measuring stiffness, yield load and maximum load. For statistical analysis a repeated measures (RM) one-way ANOVA for multiple comparisons was used. The significance was set at P<0.05. RESULTS: During the load to failure tests of the original MPFL the following results were measured: stiffness 29.4 N/mm (+9.8), yield load 167.8 N (+80) and maximum load to failure 190.7 N (+82.8). The results in the QT-technique group were as follows: maximum elongation after 1000 cycles 2.1 mm (+0.8), stiffness 33.6 N/mm (+6.8), yield load 147.1 N (+65.1) and maximum load to failure 205 N (+77.8). There were no significant differences in all tested parameters. CONCLUSIONS: In a human cadaveric model using a strip of quadriceps-tendon 10 mm wide and 3mm deep, the biomechanical properties match those of the original MPFL when tested as a reconstruction. CLINICAL RELEVANCE: The tested QT-technique shows sufficient primary stability with comparable biomechanical parameters to the intact MPFL.


Assuntos
Artroplastia/métodos , Instabilidade Articular/cirurgia , Ligamentos Articulares/fisiopatologia , Ligamentos Articulares/cirurgia , Articulação Patelofemoral/cirurgia , Tendões/transplante , Idoso , Cadáver , Dissecação , Humanos , Instabilidade Articular/patologia , Instabilidade Articular/fisiopatologia , Ligamentos Articulares/patologia , Pessoa de Meia-Idade , Articulação Patelofemoral/patologia , Articulação Patelofemoral/fisiopatologia , Músculo Quadríceps , Amplitude de Movimento Articular , Suporte de Carga
12.
Am J Sports Med ; 38(11): 2281-7, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20889985

RESUMO

BACKGROUND: Lateral meniscectomy contributes to early-onset osteoarthritis. Biomechanical properties of sutures repairs for complete radial meniscal tears remain unknown. HYPOTHESIS: Double horizontal suture techniques for repair of radial meniscal tears with a shorter distance from the meniscal rim provide significantly higher structural properties than do comparable single-suture techniques with a wider distance from the meniscal rim. STUDY DESIGN: Controlled laboratory study. METHODS: In 55 fresh-frozen porcine menisci, standardized complete radial meniscal tears were repaired with different distances from the meniscal rim and tear edges and with different numbers of sutures. In group A, the suture was 4 mm from the tear and 8 mm from the meniscal rim; group B, 2 mm from tear; group C, 2 mm from tear, 12 mm from rim; group D, double-loop technique, 2 mm from tear, 5 mm and 10 mm from rim; group E, longitudinal tear sutured with 1 loop, 8 mm from rim, and 4 mm between stitches. The specimens were cyclically loaded 1000 times between 5 and 20 N and loaded to failure. RESULTS: All repaired constructs survived the cyclic loading protocol. Compared with the single-loop techniques, the double-loop technique (group D) showed a significantly higher maximum load and yield load and significantly lower displacement after 1000 cycles. Compared with group B, group C had a higher displacement after 1000 cycles (P < .05), and its stiffness showed a descriptive negative trend (P = .09). Displacement after cycling testing in group C was higher than in groups B and D (P < .05). CONCLUSION: Repair of radial meniscal tears with a second suture and shorter distance from the meniscal rim has a positive influence on primary stability. Different distances from tear edges apparently have no influence on structural properties. CLINICAL RELEVANCE: Horizontal sutures for repair of radial meniscal tears provide high stability and can be enhanced with a second horizontal suture and shorter distance from the meniscal rim.


Assuntos
Meniscos Tibiais/cirurgia , Procedimentos Ortopédicos/métodos , Estresse Fisiológico , Suturas , Adaptação Fisiológica , Análise de Variância , Animais , Fenômenos Biomecânicos , Estudos de Viabilidade , Humanos , Traumatismos do Joelho/cirurgia , Modelos Animais , Procedimentos Ortopédicos/efeitos adversos , Procedimentos Ortopédicos/instrumentação , Osteoartrite do Joelho/etiologia , Estatísticas não Paramétricas , Suínos , Resistência à Tração , Lesões do Menisco Tibial , Suporte de Carga
13.
Arch Orthop Trauma Surg ; 126(4): 253-9, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16273379

RESUMO

INTRODUCTION: Femoral tunnel placement has a great influence on the clinical outcome after PCL reconstruction. MATERIALS AND METHODS: Using a robotic/universal force moment sensor (UFS) testing system, we examined joint kinematics and in situ forces of human knees following soft-tissue single bundle PCL reconstruction fixed at the center of the femoral attachment. RESULTS: Posterior tibial translation significantly increased at all flexion angles after transsection of the posterior cruciate ligament (p<0.05). PCL reconstruction resulted in significantly less posterior tibial translation at all flexion angles when compared to the PCL deficient knee (p<0.05). The differences in the in situ force between the intact ligament and the reconstructed graft were statistical significant (p<0.05). CONCLUSION: Single bundle PCL reconstruction with a soft-tissue graft fixed at the center of the femoral attachment is able to reduce the posterior tibial translation significantly. However, it cannot restore kinematics of the intact knee and in situ forces of the intact PCL.


Assuntos
Articulação do Joelho/fisiologia , Ligamento Cruzado Posterior/fisiologia , Ligamento Cruzado Posterior/cirurgia , Idoso , Fenômenos Biomecânicos , Cadáver , Desenho de Equipamento , Humanos , Pessoa de Meia-Idade , Ligamento Cruzado Posterior/transplante , Amplitude de Movimento Articular , Robótica/instrumentação
14.
Arch Orthop Trauma Surg ; 124(9): 614-20, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15372279

RESUMO

INTRODUCTION: Surgical reconstruction of the posterior cruciate ligament (PCL) is recommended in acute injuries that result in severe tibial subluxation and instability. The surgical outcome level may be affected by the tibial fixation site. In response to a 110-N posterior tibial load, kinematics and in situ forces of anatomical soft-tissue graft fixation in single-bundle PCL reconstruction using an interference screw fixation are significantly closer to those in the intact knee than with extracortical fixation with two staples. MATERIALS AND METHODS: Using a robotic/universal force moment sensor (UFS) testing system, we examined joint kinematics and in situ forces of porcine knees following single-bundle PCL reconstruction fixed at two different tibial fixation sites: anatomical interference screw and extracortical fixation. RESULTS: The site of the tibial graft fixation had significant effect on the resulting posterior displacement and in situ forces of the graft. Both PCL reconstruction techniques reduced the posterior tibial translation significantly. Proximal fixation techniques provided significantly less posterior tibial translation than extracortical fixation. Single-bundle PCL reconstruction with an interference screw showed higher in situ forces of the graft than the extracortical fixation. CONCLUSIONS: The kinematics and in situ forces of a single-bundle PCL reconstruction using an interference screw fixation technique are superior to the primary stability of an extracortical fixation with staples.


Assuntos
Ligamento Cruzado Posterior/cirurgia , Robótica , Tendões/transplante , Animais , Fenômenos Biomecânicos , Parafusos Ósseos , Suturas , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA