RESUMO
Electrochemical aptamer-based sensors support the high-frequency, real-time monitoring of molecules-of-interest in vivo. Achieving this requires methods for correcting the sensor drift seen during in vivo placements. While this correction ensures EAB sensor measurements remain accurate, as drift progresses it reduces the signal-to-noise ratio and precision. Here, we show that enzymatic cleavage of the sensor's target-recognizing DNA aptamer is a major source of this signal loss. To demonstrate this, we deployed a tobramycin-detecting EAB sensor analog fabricated with the DNase-resistant "xenonucleic acid" 2'O-methyl-RNA in a live rat. In contrast to the sensor employing the equivalent DNA aptamer, the 2'O-methyl-RNA aptamer sensor lost very little signal and had improved signal-to-noise. We further characterized the EAB sensor drift using unstructured DNA or 2'O-methyl-RNA oligonucleotides. While the two devices drift similarly in vitro in whole blood, the in vivo drift of the 2'O-methyl-RNA-employing device is less compared to the DNA-employing device. Studies of the electron transfer kinetics suggested that the greater drift of the latter sensor arises due to enzymatic DNA degradation. These findings, coupled with advances in the selection of aptamers employing XNA, suggest a means of improving EAB sensor stability when they are used to perform molecular monitoring in the living body.
Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Técnicas Eletroquímicas , Aptâmeros de Nucleotídeos/química , Técnicas Eletroquímicas/métodos , Técnicas Biossensoriais/métodos , Animais , Ratos , Tobramicina/análiseRESUMO
Electrochemical, aptamer-based (EAB) sensors are the first molecular monitoring technology that is (1) based on receptor binding and not the reactivity of the target, rendering it fairly general, and (2) able to support high-frequency, real-time measurements in situ in the living body. To date, EAB-derived in vivo measurements have largely been performed using three electrodes (working, reference, counter) bundled together within a catheter for insertion into the rat jugular. Exploring this architecture, here we show that the placement of these electrodes inside or outside of the lumen of the catheter significantly impacts sensor performance. Specifically, we find that retaining the counter electrode within the catheter increases the resistance between it and the working electrode, increasing the capacitive background. In contrast, extending the counter electrode outside the lumen of the catheter reduces this effect, significantly enhancing the signal-to-noise of intravenous molecular measurements. Exploring counter electrode geometries further, we find that they need not be larger than the working electrode. Putting these observations together, we have developed a new intravenous EAB architecture that achieves improved performance while remaining short enough to safely emplace in the rat jugular. These findings, though explored here with EAB sensors may prove important for the design of many electrochemical biosensors.
Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Ratos , Animais , Aptâmeros de Nucleotídeos/química , Técnicas Eletroquímicas , EletrodosRESUMO
DNA self-assembled monolayers (SAMs) were prepared using potential-assisted deposition on clean gold single-crystal bead electrodes under a number of conditions (constant or square-wave potential perturbations in TRIS or phosphate immobilization buffers with and without Cl-). The local environment around the fluorophore-labeled DNA tethered to the electrode surface was characterized using in situ fluorescence microscopy during electrochemical measurements as a function of the underlying surface crystallography. Potential-assisted deposition from a TRIS buffer containing Cl- created DNA SAMs that were uniformly distributed on the surface with little preference to the underlying crystallography. A constant (+0.4 V/SCE) or a square-wave potential perturbation (+0.4 to -0.3 V/SCE, 50 Hz) resulted in similar DNA-modified surfaces in TRIS immobilization buffer. Deposition using a square-wave potential without Cl- resulted in lower DNA surface coverage. Despite this, the local environment around the DNA in the SAM appears to be densely packed. This implies the formation of clusters of densely packed DNA in the SAM. This effect was also demonstrated when depositing from a phosphate buffer. DNA clusters were significantly reduced when Cl- was present in the buffer. Clusters were most prevalent on the low-index plane surfaces (e.g., {111} and {100}) and less on the higher-index planes (e.g., {210} or {311}). A mechanism is proposed to rationalize the formation of DNA-clustered regions for deposition using a square-wave potential perturbation. The conditions for creating clusters of DNA in a SAM or for preventing these clusters from forming provide an approach for tailoring the surfaces used for biosensing.
Assuntos
DNA , Ouro , DNA/genética , Eletrodos , Microscopia de Fluorescência , Propriedades de SuperfícieRESUMO
Manipulating the composition of a mixed alkylthiol self-assembled monolayer (SAM) modified gold surface using both electrochemical and electroless methods is demonstrated. Through the use of fluorophore labeled thiolated DNA and in situ fluorescence microscopy with a gold single crystal bead electrode, a procedure was developed to study and quantify the selective desorption of an alkylthiolate SAM. This method enabled a self-consistent measurement of the removal of the SAM from the 111 surface compared to the 100 surface region at various potentials. A 20-fold increase in the electrochemical removal and replacement of the SAM from the 111 surface over the 100 surface was realized at -0.8 V/AgAgCl. A related procedure was developed for the solution-based electroless removal of the SAM using NaBH4 achieving a similar selectivity at the same potential. Unfortunately, in the electroless process fine control over the reducing potential was difficult to achieve. In addition, working in the presence of O2 complicates the solution potential measurement due to depolarization by the reduction of O2, resulting in a less clear relationship between selectivity and measured solution potential. Interestingly, the electrochemical method was not disturbed by the presence of O2. In preparation for work with Au nanorods, electrochemical measurements were performed in electrolyte that included 1 mM CTAB and was found to not interfere with this method. Preliminary results are promising for using this methodology for treatment of acid-terminated alkylthiol modified Au nanorods.
RESUMO
We report herein a general catalytic method for Csp(2)-Csp(3) bond formation through C-F activation. The process uses an inexpensive nickel complex with either diorganozinc or alkylzinc halide reagents, including those with ß-hydrogen atoms. A variety of fluorine substitution patterns and functional groups can be readily incorporated. Sequential reactions involving different precatalysts and coupling partners permit the synthesis of densely functionalized fluorinated building blocks.
Assuntos
Complexos de Coordenação/química , Flúor/química , Halogênios/química , Níquel/química , Catálise , Estrutura MolecularRESUMO
Electrochemical aptamer-based (EAB) sensors represent the first molecular measurement technology that is both (1) independent of the chemical reactivity of the target, and thus generalizable to many targets and (2) able to function in an accurate, drift-corrected manner in situ in the living body. Signaling in EAB sensors is generated when an electrode-bound aptamer binds to its target ligand, altering the rate of electron transfer from an attached redox reporter and producing an easily detectable change in peak current when the sensor is interrogated using square wave voltammetry. Due to differences in the microscopic surface area of the interrogating electrodes, the baseline peak currents obtained from EAB sensors, however, can be highly variable. To overcome this, we have historically performed single-point calibration using measurements performed in a single sample of known target concentration. Here, however, we explore approaches to EAB sensor operation that negate the need to perform even single-point calibration of individual sensors. These are a ratiometric approach employing the ratio of the peak currents observed at two distinct square wave frequencies, and a kinetic differential measurement approach that employs the difference between peak currents seen at the two frequencies. Using in vivo measurements of vancomycin and phenylalanine as our test bed, we compared the output of these methods with that of the same sensor when single-point calibration was employed. Doing so we find that both methods support accurately drift-corrected measurements in vivo in live rats, even when employing rather crudely handmade devices. By removing the need to calibrate each individual sensor in a sample of known target concentration, these interrogation methods should significantly simplify the use of EAB sensors for in vivo applications.
Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Técnicas Eletroquímicas , Animais , Aptâmeros de Nucleotídeos/química , Ratos , Técnicas Eletroquímicas/métodos , Técnicas Eletroquímicas/instrumentação , Técnicas Biossensoriais/métodos , Calibragem , Eletrodos , Ratos Sprague-Dawley , VancomicinaRESUMO
The electrochemical aptamer-based (EAB) sensor platform is the only molecular monitoring approach yet reported that is (1) real time and effectively continuous, (2) selective enough to deploy in situ in the living body, and (3) independent of the chemical or enzymatic reactivity of its target, rendering it adaptable to a wide range of analytes. These attributes suggest the EAB platform will prove to be an important tool in both biomedical research and clinical practice. To advance this possibility, here we have explored the stability of EAB sensors upon storage, using retention of the target recognizing aptamer, the sensor's signal gain, and the affinity of the aptamer as our performance metrics. Doing so we find that low-temperature (-20 °C) storage is sufficient to preserve sensor functionality for at least six months without the need for exogenous preservatives.
RESUMO
The availability of high-frequency, real-time measurements of the concentrations of specific metabolites in cell culture systems will enable a deeper understanding of cellular metabolism and facilitate the application of good laboratory practice standards in cell culture protocols. However, currently available approaches to this end either are constrained to single-time-point and single-parameter measurements or are limited in the range of detectable analytes. Electrochemical aptamer-based (EAB) biosensors have demonstrated utility in real-time monitoring of analytes in vivo in blood and tissues. Here, we characterize a pH-sensing capability of EAB sensors that is independent of the specific target analyte of the aptamer sequence. We applied this dual-purpose EAB to the continuous measurement of pH and phenylalanine in several in vitro cell culture settings. The miniature EAB sensor that we developed exhibits rapid response times, good stability, high repeatability, and biologically relevant sensitivity. We also developed and characterized a leak-free reference electrode that mitigates the potential cytotoxic effects of silver ions released from conventional reference electrodes. Using the resulting dual-purpose sensor, we performed hourly measurements of pH and phenylalanine concentrations in the medium superfusing cultured epithelial tumor cell lines (A549, MDA-MB-23) and a human fibroblast cell line (MRC-5) for periods of up to 72 h. Our scalable technology may be multiplexed for high-throughput monitoring of pH and multiple analytes in support of the broad metabolic qualification of microphysiological systems.
RESUMO
Electrochemical aptamer-based (EAB) sensors are capable of measuring the concentrations of specific molecules in vivo, in real time, and with a few-second time resolution. For their signal transduction mechanism, these sensors utilize a binding-induced conformational change in their target-recognizing, redox-reporter-modified aptamer to alter the rate of electron transfer between the reporter and the supporting electrode. While a variety of voltammetric techniques have been used to monitor this change in kinetics, they suffer from various drawbacks, including time resolution limited to several seconds and sensor-to-sensor variation that requires calibration to remove. Here, however, we show that the use of fast Fourier transform electrochemical impedance spectroscopy (FFT-EIS) to interrogate EAB sensors leads to improved (here better than 2 s) time resolution and calibration-free operation, even when such sensors are deployed in vivo. To showcase these benefits, we demonstrate the approach's ability to perform real-time molecular measurements in the veins of living rats.
Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Ratos , Animais , Aptâmeros de Nucleotídeos/química , Espectroscopia Dielétrica , Técnicas Eletroquímicas/métodos , Técnicas Biossensoriais/métodos , EletrodosRESUMO
Knowledge of drug concentrations in the brains of behaving subjects remains constrained on a number of dimensions, including poor temporal resolution and lack of real-time data. Here, however, we demonstrate the ability of electrochemical aptamer-based sensors to support seconds-resolved, real-time measurements of drug concentrations in the brains of freely moving rats. Specifically, using such sensors, we achieve <4 µM limits of detection and 10-s resolution in the measurement of procaine in the brains of freely moving rats, permitting the determination of the pharmacokinetics and concentration-behavior relations of the drug with high precision for individual subjects. In parallel, we have used closed-loop feedback-controlled drug delivery to hold intracranial procaine levels constant (±10%) for >1.5 hours. These results demonstrate the utility of such sensors in (i) the determination of the site-specific, seconds-resolved neuropharmacokinetics, (ii) enabling the study of individual subject neuropharmacokinetics and concentration-response relations, and (iii) performing high-precision control over intracranial drug levels.
Assuntos
Encéfalo , Procaína , Ratos , Animais , RetroalimentaçãoRESUMO
Electrochemical aptamer-based (EAB) sensors support the real-time, high frequency measurement of pharmaceuticals and metabolites in-situ in the living body, rendering them a potentially powerful technology for both research and clinical applications. Here we explore quantification using EAB sensors, examining the impact of media selection and temperature on measurement performance. Using freshly-collected, undiluted whole blood at body temperature as both our calibration and measurement conditions, we demonstrate accuracy of better than ± 10% for the measurement of our test bed drug, vancomycin. Comparing titrations collected at room and body temperature, we find that matching the temperature of calibration curve collection to the temperature used during measurements improves quantification by reducing differences in sensor gain and binding curve midpoint. We likewise find that, because blood age impacts the sensor response, calibrating in freshly collected blood can improve quantification. Finally, we demonstrate the use of non-blood proxy media to achieve calibration without the need to collect fresh whole blood.
Assuntos
Aptâmeros de Nucleotídeos , Calibragem , VancomicinaRESUMO
The ability to monitor drugs, metabolites, hormones, and other biomarkers in situ in the body would greatly advance both clinical practice and biomedical research. To this end, we are developing electrochemical aptamer-based (EAB) sensors, a platform technology able to perform real-time, in vivo monitoring of specific molecules irrespective of their chemical or enzymatic reactivity. An important obstacle to the deployment of EAB sensors in the challenging environments found in the living body is signal drift, whereby the sensor signal decreases over time. To date, we have demonstrated a number of approaches by which this drift can be corrected sufficiently well to achieve good measurement precision over multihour in vivo deployments. To achieve a much longer in vivo measurement duration, however, will likely require that we understand and address the sources of this effect. In response, here, we have systematically examined the mechanisms underlying the drift seen when EAB sensors and simpler, EAB-like devices are challenged in vitro at 37 °C in whole blood as a proxy for in vivo conditions. Our results demonstrate that electrochemically driven desorption of a self-assembled monolayer and fouling by blood components are the two primary sources of signal loss under these conditions, suggesting targeted approaches to remediating this degradation and thus improving the stability of EAB sensors and other, similar electrochemical biosensor technologies when deployed in the body.
RESUMO
The preparation of DNA self-assembled monolayers (SAMs) on single-crystal gold bead electrodes using an applied potential is evaluated with in situ electrochemical fluorescence microscopy. Applying a constant deposition potential or a square-wave potential perturbation during the formation of DNA SAMs is compared for two different modification methods: DNA SAM formation on a clean gold surface followed by alkythiol backfilling (as is typically done in the literature) or via thiol-exchange on an alkylthiol-modified gold surface. DNA SAMs prepared from a chloride-containing deposition buffer were not significantly different when using either square-wave potential perturbation or at a constant applied potential even when considering different surface crystallographies. Greater variations were observed when applying more positive potentials for both DNA thiol-exchange and DNA adsorption on clean Au. Our results suggest that using either a constant potential or a square-wave potential perturbation for 5 min both create defects by weakening the gold-thiol interaction. When the deposition is performed with the adsorption of chloride ions from the electrolyte, the electrodeposition results in a similar increase in DNA coverage when compared to depositions performed at open circuit potentials.