Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Crit Care Med ; 38(9): 1875-81, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20562697

RESUMO

OBJECTIVE: The Ultrasonic Cardiac Output Monitor is a noninvasive method of hemodynamic assessment and monitoring in critically ill patients. There are no published reference ranges for normal values in children for this device. This study aimed to establish normal ranges for cardiovascular indices measured using Ultrasonic Cardiac Output Monitor in children aged 0-12 yrs old and to assess interobserver reliability. DESIGN: This was a population-based cross-sectional observational study. SETTING: Schools and kindergartens in Hong Kong. SUBJECTS: Chinese children aged up to 12 yrs old. INTERVENTIONS: Two operators performed Ultrasonic Cardiac Output Monitor scans on each child together with standard oscillometric measurement of blood pressure and heart rate. Software intrinsic to the Ultrasonic Cardiac Output Monitor device produces values for stroke volume, cardiac output, and systemic vascular resistance. For each parameter, normal ranges were defined as lying between the 2.5th and 97.5th percentiles. Interobserver reliability was assessed with Bland-Altman plots, coefficients of variation, and intraclass correlation. MEASUREMENTS AND MAIN RESULTS: A total of 1,197 Chinese children (55% boys) were scanned. Normal ranges of values for cardiac output, stroke volume, and systemic vascular resistance indices are presented. Interobserver reliability for Ultrasonic Cardiac Output Monitor was superior to that for standard blood pressure and heart rate measurement. CONCLUSIONS: This large study presents normal values for cardiovascular indices in children using the Ultrasonic Cardiac Output Monitor with good interobserver reliability.


Assuntos
Débito Cardíaco , Ecocardiografia/normas , Testes de Função Cardíaca/normas , Criança , Pré-Escolar , Estudos Transversais , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Variações Dependentes do Observador , Valores de Referência
2.
Physiol Rep ; 5(6)2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28320891

RESUMO

The ultrasonic cardiac output monitor (USCOM) is a noninvasive transcutaneous continuous wave Doppler method for assessing hemodynamics. There are no published reference ranges for normal values in adults (aged 18-60 years) for this device. This study aimed to (1) measure cardiovascular indices using USCOM in healthy adults aged 18-60 years; (2) combine these data with those for healthy children (aged 0-12), adolescents (aged 12-18), and the elderly (aged over 60) from our previously published studies in order to present normal ranges for all ages, and (3) establish normal ranges of USCOM-derived variables according to both weight and age. This was a population-based cross-sectional observational study of healthy Chinese subjects aged 0.5-89 years in Hong Kong. USCOM scans were performed on all subjects, to produce measurements including stroke volume, cardiac output, and systemic vascular resistance. Data from previously published studies (children, adolescents, and the elderly) were included. Normal ranges were defined as lying between the 2.5th and 97.5th percentiles. A total of 2218 subjects were studied (mean age = 16.4, range = 0.5-89; 52% male). From previous studies, 1197 children (aged 0-12, 55% male), 590 adolescents (aged 12-18, 49% male), and 77 elderly (aged 60-89, 55% male) were included. New data were collected from 354 adults aged 18-60 (47% male). Normal ranges are presented according to age and weight. We present comprehensive normal ranges for hemodynamic parameters obtained with USCOM in healthy subjects of all ages from infancy to the elderly.


Assuntos
Débito Cardíaco/fisiologia , Hemodinâmica/fisiologia , Volume Sistólico/fisiologia , Resistência Vascular/fisiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Criança , Pré-Escolar , Estudos Transversais , Feminino , Hong Kong , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Valores de Referência , Ultrassonografia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA