Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
2.
J Virol Methods ; 322: 114825, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37778539

RESUMO

One consequence of the ongoing coronavirus disease pandemic was the rapid development of both in-house and commercial serological assays detecting anti-SARS-CoV-2 antibodies, in an effort to reliably detect acute and past SARS-CoV-2 infections. It is crucial to evaluate the quality of these serological tests and consequently the sero-epidemiological studies that are performed with the respective tests. Here, we describe the set-up and results of a comparative study, in which a laboratory contracted by the European Centre for Disease Prevention and Control offered a centralised service to EU/EEA Member and pre-accession Member States to test representative serum specimens with known serological results, with the gold standard technique (virus neutralisation tests) to determine the presence of neutralising antibodies. Laboratories from 12 European countries shared 719 serum specimens with the contractor laboratory. We found that in-house serological tests detecting neutralising antibodies showed the highest percent agreement, both positive and negative, with the virus neutralisation test results. Despite extensive differences in virus neutralisation protocols neutralisation titres showed a strong correlation. From the commercial assays, the best positive percent agreement was found for SARS-CoV-2 IgG (sCOVG) (Siemens - Atellica IM Analyzer). Despite lower positive percent agreement of LIAISON SARS-CoV-2 TrimericS IgG kit (Diasorin Inc.), the obtained results showed relatively good correlation with neutralisation titres. The set-up of this study allowed for high comparability between laboratories and enabled laboratories that do not have the capacity or capability to perform VNTs themselves. Given the variety of in-house protocols detecting SARS-CoV-2 specific neutralising antibodies, including the virus strain, it could be of interest to select reference isolates for SARS-CoV-2 diagnostic to be made available for interested EU Member States and pre-accession countries.


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Teste para COVID-19 , Técnicas de Laboratório Clínico/métodos , Anticorpos Antivirais , Europa (Continente) , Imunoglobulina G , Anticorpos Neutralizantes
3.
Front Epidemiol ; 2: 944820, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-38455297

RESUMO

Introduction: SARS-CoV-2 infection rates and related mortality in elderly from residential care facilities are high. The aim of this study was to explore the immune status after COVID-19 vaccination in people 65 years and older. Methods: The study involved volunteer participants living in residential care facilities. The level of anti-Spike/RBD antibodies was measured at 2-12 weeks after complete vaccination, using chemiluminescent microparticle immunoassay (SARS-CoV-2 IgG II Quant Abbott). Results: We have analyzed 635 serum samples collected from volunteers living in 21 Residential Care Facilities. With one exception, in which the vaccination was done with the Moderna vaccine, all volunteers received the Pfizer-Comirnaty vaccine. Individuals enrolled in the study had ages between 65-110 years (median 79 years). Of the people tested, 54.8% reported at least one comorbidity and 59.2% reported having had COVID-19 before vaccination. The presence of anti-S/RBD antibodies at a protective level was detected in 98.7% of those tested (n = 627 persons) with a wide variation of antibody levels, from 7.1 to 5,680 BAU/ml (median 1287 BAU/ml). Antibody levels appeared to be significantly correlated to previous infection (r = 0.302, p = 0.000). Conclusions: The study revealed the presence of anti-SARS CoV-2 antibodies in a significant percentage of those tested (98.7%). Of these, more than half had high antibody levels. Pre-vaccination COVID-19 was the only factor found to be associated with higher anti-S/RBD levels. The significant response in elderly people, even in those with comorbidities, supports the vaccination measure for this category, irrespective of associated disabilities or previous infection.

4.
Biomedicines ; 10(7)2022 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-35884831

RESUMO

The continuous variability of SARS-CoV-2 and the rapid waning of specific antibodies threatens the efficacy of COVID-19 vaccines. We aimed to evaluate antibody kinetics one year after SARS-CoV-2 vaccination with an mRNA vaccine in healthcare workers (HCW), with or without a booster. A marked decline in anti-Spike(S)/Receptor Binding Domain (RBD) antibody levels was registered during the first eight months post-vaccination, followed by a transitory increase after the booster. At three months post-booster an increased antibody level was maintained only in HCW vaccinated after a prior infection, who also developed a higher and long-lasting level of anti-S IgA antibodies. Still, IgG anti-nucleocapsid (NCP) fades five months post-SARS-CoV-2 infection. Despite the decline in antibodies one-year post-vaccination, 68.2% of HCW preserved the neutralization capacity against the ancestral variant, with a decrease of only 17.08% in the neutralizing capacity against the Omicron variant. Nevertheless, breakthrough infections were present in 6.65% of all participants, without any correlation with the previous level of anti-S/RBD IgG. Protection against the ancestral and Omicron variants is maintained at least three months after a booster in HCW, possibly reflecting a continuous antigenic stimulation in the professional setting.

5.
Front Immunol ; 13: 1079884, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36713452

RESUMO

Short summary: We investigated changes in serologic measurements after COVID-19 vaccination in 19,422 subjects. An individual-level analysis was performed on standardized measurements. Age, infection, vaccine doses, time between doses and serologies, and vaccine type were associated with changes in serologic levels within 13 months. Background: Persistence of vaccine immunization is key for COVID-19 prevention. Methods: We investigated the difference between two serologic measurements of anti-COVID-19 S1 antibodies in an individual-level analysis on 19,422 vaccinated healthcare workers (HCW) from Italy, Spain, Romania, and Slovakia, tested within 13 months from first dose. Differences in serologic levels were divided by the standard error of the cohort-specific distribution, obtaining standardized measurements. We fitted multivariate linear regression models to identify predictors of difference between two measurements. Results: We observed a progressively decreasing difference in serologic levels from <30 days to 210-240 days. Age was associated with an increased difference in serologic levels. There was a greater difference between the two serologic measurements in infected HCW than in HCW who had never been infected; before the first measurement, infected HCW had a relative risk (RR) of 0.81 for one standard deviation in the difference [95% confidence interval (CI) 0.78-0.85]. The RRs for a 30-day increase in time between first dose and first serology, and between the two serologies, were 1.08 (95% CI 1.07-1.10) and 1.04 (95% CI 1.03-1.05), respectively. The first measurement was a strong predictor of subsequent antibody decrease (RR 1.60; 95% CI 1.56-1.64). Compared with Comirnaty, Spikevax (RR 0.83, 95% CI 0.75-0.92) and mixed vaccines (RR 0.61, 95% CI 0.51-0.74) were smaller decrease in serological level (RR 0.46; 95% CI 0.40-0.54). Conclusions: Age, COVID-19 infection, number of doses, time between first dose and first serology, time between serologies, and type of vaccine were associated with differences between the two serologic measurements within a 13-month period.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Humanos , Lactente , COVID-19/prevenção & controle , Anticorpos , Pessoal de Saúde , Itália
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA