Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
BMC Cardiovasc Disord ; 21(1): 590, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34876008

RESUMO

BACKGROUND: Optimal projection is essential for valve deployment during transcatheter aortic valve implantation (TAVI). The purpose of this study was to propose an approach to predict optimal projection in TAVI candidates with different aortic valve anatomies. METHODS: 331 patients undergoing self-expanding TAVI were included and the so-called non-coronary cusp (NCC)-parallel technique was utilized, which generated the predicted projection by connecting NCC commissures on the transverse plane on the pre-procedural computed tomography images. RESULTS: 37.8% of the study cohort were bicuspid aortic valve (BAV) patients. Around 80% of both NCC-parallel views and final views were in the right anterior oblique (RAO) and caudal (CAU) quadrant. There was less than 5° change required from the NCC-parallel view to the final implanted view in 79% of tricuspid aortic valve (TAV) patients but only in 27% (13/48) of type 0 BAV patients with coronary arteries originated from the different cusps. After excluding the above mentioned BAV patients, 62.3% (48/77) of BAV patients needed less than 5° change to achieve optimal projection and only in 8 patients, the angular change was larger than 10° in either left/right anterior oblique or cranial/caudal direction. CONCLUSIONS: The NCC-parallel technique provides reliable prediction for optimal projection in self-expanding TAVI in all TAV and most BAV patients, with a vast majority of views in the RAO and CAU quadrant.


Assuntos
Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/cirurgia , Tomografia Computadorizada Multidetectores , Tomografia Computadorizada por Raios X , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Valva Aórtica/anormalidades , Tomada de Decisão Clínica , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese
2.
Herz ; 46(Suppl 2): 166-172, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32880663

RESUMO

BACKGROUND: Some patients referred for transcatheter aortic valve replacement (TAVR) have excessively large annuli (ELA) without device options according to current sizing charts. This retrospective study aims to summarize the presentation and outcomes of ELA patients receiving first-generation self-expanding valves. METHODS: The TAVR database was reviewed in search for cases of self-expanding valves. Patients who had annuli exceeding the perimeter limit on the device sizing chart were referred to as the ELA group. Patients who had annuli within the range covered by the two largest sizes and received the corresponding valve size served as the control group (CG). Baseline, procedures, outcomes, and imaging characteristics on multislice computed tomography (MSCT), such as native anatomy and postimplant stent geometry, were compared. RESULTS: A total of 28 patients were included in the ELA group and 82 in the CG. The patients in the ELA group were younger than those in the CG (72.5 ± 6.2 vs. 75.4 ± 5.8 years, P = 0.03). The median intended perimeter oversizing in relation to the annulus in the ELA group was much smaller than in the CG (-0.4 [-4.6, 4.1] % vs. 16.1 [11.7, 20.8] %, P < 0.01). The calcium burden in the aortic root was around 1.3-fold greater in the ELA group than the CG (756.0 [534.5, 1670.9] vs. 582.1 [310.3, 870.9] mm3, P = 0.01). The need for second valve implantation was higher in ELA (21.4% vs. 12.2%, P = 0.23) but no valve embolization was encountered. The 1­year follow-up was comparable, including >mild paravalvular leak. CONCLUSION: Under cautious patient selection using MSCT, TAVR with self-expanding valves in patients with ELA appears feasible. Supra-annular structures likely provide the extra anchoring.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Tomografia Computadorizada Multidetectores , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 96(7): 1491-1497, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32400115

RESUMO

OBJECTIVE: We hypothesize that different degree of pre-existing aortic regurgitation (AR) may affect the presence of hypo-attenuated leaflet thickening (HALT) after transcatheter aortic valve replacement (TAVR). BACKGROUND: The mechanism of the presence of HALT post-TAVR is not fully understood. METHODS: We retrospectively evaluated the post-procedural multi-slice computed tomography (MSCT) before discharge for evidence of HALT. Patients were grouped according to the degree of pre-existing AR. Baseline, native anatomy and procedure details were compared, then multivariate regression was performed. RESULTS: MSCT analyzed was performed at a median of 6 days post-TAVR in 179 patients. HALT was detected in 10.6% of patients. After adjusting for variables that were significantly different between groups, pre-existing ≥ moderate AR was protective to the risk of HALT (OR 0.15, 95% CI 0.03-0.84, p = .03). Stratifying for factors that might explain the impact of pre-existing AR on HALT, patients with a small Sinus of Valsalva, non-eccentric remodeling and receiving a large bioprosthesis experienced a sevenfold higher risk for HALT (OR 7.16, 95% CI 2.05-25.08, p = .002). CONCLUSIONS: Patients underwent TAVR with pre-existing ≥ moderate AR appeared to experience a lower incidence of early HALT compared to those patients with less than moderate AR, which may be explained by a larger Sinus of Valsalva and a higher proportion of LV eccentric remodeling.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
4.
Catheter Cardiovasc Interv ; 95 Suppl 1: 616-623, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31943783

RESUMO

OBJECTIVES: We evaluated the safety and usefulness of preparatory anatomical reshaping with a geometric hourglass-shaped balloon to optimize transcatheter aortic valve replacement (TAVR) outcomes in bicuspid aortic valve (BAV) stenosis. BACKGROUND: TAVR has been increasingly performed for BAV stenosis; however, technical challenges remain. Procedural results are suboptimal given unfavorable valvular anatomies. METHODS: Eligible patients with BAV stenosis were enrolled to undergo aortic valve predilatation with the hourglass-shaped TAV8 balloon before TAVR using the self-expandable Venus A-Valve. Procedural details and outcomes were compared to a sequential group of patients with BAV who underwent TAVR with the same device following preparatory dilatation using a cylindrical balloon. RESULTS: A total of 22 patients were enrolled in the TAV8 group and 53 were included in the control group. Valve downsizing was less common in the TAV8 group (36.4 vs. 67.9%; p = .012). Stable valve release and optimal implant depth were consistently achieved in the TAV8 group with no requirement for a second valve (0 vs. 17.0%; p = .039) and with higher device success rates (100.0 vs 77.4%; p = .014). Residual aortic regurgitation graded as ≥mild was less common in the TAV8 group (13.6 vs 45.3%; p = .009). Mortality was similar (0 vs. 3.8%; p = 1); no major/disabling stroke or conversion to open-heart surgery was seen in either group within 30 days. CONCLUSIONS: Compared with standard cylindrical balloon valvuloplasty, preparatory reshaping with the hourglass-shaped balloon before self-expandable TAVR in BAV was associated with significantly better procedural results and may encourage more promising outcomes.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valvuloplastia com Balão/instrumentação , Doença da Válvula Aórtica Bicúspide/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Valvuloplastia com Balão/efeitos adversos , Valvuloplastia com Balão/mortalidade , Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/mortalidade , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Feminino , Humanos , Masculino , Projetos Piloto , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
5.
BMC Cardiovasc Disord ; 20(1): 229, 2020 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-32423380

RESUMO

BACKGROUND: To explore why bicuspid aortic stenosis has certain clinical differences from the tricuspid morphology, we evaluated the metabolomics profile involved in bicuspid aortic valve (BAV) aortic stenosis prior to and after transcatheter aortic valve replacement (TAVR) in comparison with tricuspid aortic valve (TAV). METHODS: In this TAVR cohort with prospectively collected data, blood samples were obtained before TAVR valve deployment and at the 7th day after TAVR, which were then sent for liquid and gas chromatography-mass spectrometry detection. Besides comparisons between BAV and TAV, BAV patients were also divided in subgroups according to baseline hemodynamics (i.e. maximal transaortic velocity, Vmax) and post-procedural reverse left ventricular (LV) remodeling (i.e. the change in LV mass index from baseline, ∆LVMI) for further analysis. Metabolic differences between groups were identified by integrating univariate test, multivariate analysis and weighted correlation network analysis algorithm. RESULTS: A total of 57 patients were enrolled including 33 BAV patients. The BAV group showed lower arginine and proline metabolism both before and post TAVR than TAV represented by decreased expression of L-Glutamine. In BAV subgroup analysis, patients with baseline Vmax > 5 m/s (n = 11) or the 4th quartile of change in ∆LVMI at one-year follow-up (i.e. poorly-recovered LV, n = 8) showed elevated arachidonic acid metabolism compared with Vmax < 4.5 m/s (n = 12) or the 1st quartile of ∆LVMI (i.e. well-recovered LV, n = 8) respectively. CONCLUSIONS: Difference in arginine and proline metabolism was identified between BAV and TAV in TAVR recipients. Elevated arachidonic acid metabolism may reflect more severe baseline hemodynamics and worse LV reserve remodeling after TAVR in BAV.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Metabolismo Energético , Doenças das Valvas Cardíacas/cirurgia , Metabolômica , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/sangue , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/fisiopatologia , Ácido Araquidônico/sangue , Arginina/sangue , Doença da Válvula Aórtica Bicúspide , Biomarcadores/sangue , Feminino , Doenças das Valvas Cardíacas/sangue , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/fisiopatologia , Hemodinâmica , Humanos , Masculino , Prolina/sangue , Estudos Prospectivos , Recuperação de Função Fisiológica , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Função Ventricular Esquerda , Remodelação Ventricular
6.
Yi Chuan ; 42(6): 599-612, 2020 Jun 20.
Artigo em Zh | MEDLINE | ID: mdl-32694118

RESUMO

Colorectal cancer (CRC) is a malignant cancer with high incidence and mortality in the world. Immunotherapy targeting neoantigens can induce durable tumor regression in cancer patients, but is almost limited to personalized precision therapy, due to the individual differences of unique neoantigens. With the discovery of many common oncogenic mutations, and such mutation-associated neoantigens could cover more patients, and hence are valuable in clinical field. However, whether the common neoantigens can be identified in CRC is unknown. Combining the somatic mutations data from 321 CRC patients with a filter standard and 7 predicted algorithms, we screened and obtained 25 HLA-A*1101-restricted common neoantigens with a high binding affinity (IC50<50 nmol/L) and presentation score (>0.90). Besides the positive epitope KRAS_G12V8-16, 11 out of 25 common neoantigens specifically induced in vitro pre- stimulated cytotoxic lymphocyte (CTL) to secrete interferon gamma (IFN-γ). Moreover, combining cell-sorting technology and single-cell RNA sequencing, the immune repertoire profiles of C1orf170_S418G413-421 and KRAS_G12V8-16-specific CTL were analyzed and validated. Their related T-cell receptor engineered T cell (TCR-T) cells could also recognize the neoantigens and secrete IFN-γ. Hence, we have established a method to screen for common neoantigens with immunogenicity in CRC based on the public somatic mutation library. It can provide essential peptide and TCR information for immunotherapies, such as peptides, dendritic cells (DC) vaccines, TCR-like antibodies, TCR-T, etc., for the CRC and other cancers, which has practical application value in the clinics.


Assuntos
Antígenos de Neoplasias , Neoplasias Colorretais , Antígenos de Neoplasias/genética , Neoplasias Colorretais/genética , Neoplasias Colorretais/imunologia , Neoplasias Colorretais/terapia , Detecção Precoce de Câncer , Humanos , Mutação , Receptores de Antígenos de Linfócitos T/genética
7.
J Interv Cardiol ; 2019: 7348964, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31777470

RESUMO

OBJECTIVES: We aimed to assess the procedural and clinical results of transcatheter aortic valve replacement (TAVR) for nonraphe bicuspid aortic stenosis (AS) with coronary vs mixed cusp fusion. BACKGROUND: It remains unclear whether cusp fusion morphology affects TAVR outcomes in patients with nonraphe bicuspid AS. METHODS: This retrospective study enrolled consecutive patients with severe symptomatic AS and type-0 bicuspid aortic valve, who underwent TAVR at our institution between 2012 and 2017. TAVR outcomes were defined based on the Valve Academic Research Consortium-2 recommendations. RESULTS: Compared to patients with mixed cusp fusion (44/71), those with coronary cusp fusion (27/71) had a larger ellipticity index for the aortic annulus (21.9% ± 9.0% vs 15.6% ± 9.3%, p=0.007) and increased left ventricular outflow tract obstruction (31.1% ± 9.4% vs 26.9% ± 7.5%, p=0.04) but comparable rates of second valve implantation (15.9% vs 14.8%), mild paravalvular leakage (PVL, 38.5% vs 30.2%), permanent pacemaker implantation (PPM, 25.9% vs 15.9%), and 30-day mortality (7.4% vs 6.8%). Use of a first-generation transcatheter heart valve was associated with higher risk for mild PVL (odds ratio (OR) = 4.37; 95% confidence interval (95% CI) = 1.14-16.75; p=0.03) but not PPM (OR = 0.77; 95% CI = 0.22-2.62; p=0.67), whereas a larger oversizing ratio tended to be associated with a higher PPM rate (OR = 1.49; 95% CI = 0.46-4.86; p=0.51) but lower incidence of mild PVL (OR = 0.51; 95% CI = 0.19-1.35; p=0.17). CONCLUSIONS: In AS patients with type-0 bicuspid valves, cusp fusion morphology does not affect the procedural or clinical results of TAVR. Use of second-generation transcatheter heart valves may provide more favorable results in such patients. This trial is registered with NCT01683474.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Próteses Valvulares Cardíacas , Humanos , Masculino , Tomografia Computadorizada Multidetectores , Desenho de Prótese
8.
BMC Infect Dis ; 19(1): 71, 2019 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-30658581

RESUMO

BACKGROUND: To provide a scientific basis for the prevention and treatment of cervical cancer (CC), we investigated the distribution characteristics and genotypes of human papillomavirus (HPV) and the prevalence of multiple HPV infections in women of different ages seeking management for abnormal cytology in Foshan City. METHODS: Screening for the 21 genotypes of HPV was carried out in 9945 females seeking management of abnormal cervical cytology results using rapid flow-through hybridization of nucleic acid molecules. The overall prevalence, genotype distribution and age-specific prevalence were examined. RESULTS: Our results indicate that the prevalence of overall, high-risk, intermediate-risk, and low-risk HPV infections was 13.5%, 12.1%, 1.3%, and 1.9%, respectively. Of the 1346 women who tested positive, 89.5% were positive for a single HPV genotype, and 10.5% were positive for ≥2 genotypes. The most frequently detected HPV genotype was HPV-16 (2.9%), followed by HPV-52 (2.9%), HPV-58 (1.5%), and HPV-CP8304 (1.0%). The highest infection prevalence was found in patients 21-30 years old (271/1670, 16.2%). CONCLUSION: The prevalence of HPV infection in women seeking management for abnormal cytology in Foshan City is highest in the younger population (21-30 years old). Similar to most previous surveys, HPV-58 and HPV-52 infections are as common as HPV-16 infection.


Assuntos
Papillomaviridae/genética , Infecções por Papillomavirus/virologia , Adulto , Idoso , Idoso de 80 Anos ou mais , China/epidemiologia , Feminino , Genótipo , Papillomavirus Humano 16/genética , Papillomavirus Humano 16/isolamento & purificação , Humanos , Pessoa de Meia-Idade , Hibridização de Ácido Nucleico , Papillomaviridae/isolamento & purificação , Infecções por Papillomavirus/epidemiologia , Prevalência , Adulto Jovem
9.
J Interv Cardiol ; 31(6): 878-884, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30079561

RESUMO

BACKGROUND: Studies of permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) specifically for bicuspid aortic valve (BAV) patients are lacking. We aim to delineate possible aspects that might affect the incidence of PPI in a retrospective cohort of BAV patients treated with early-generation self-expanding devices. METHODS: A total of 80 patients with bicuspid morphology who successfully underwent TAVR by self-expanding devices without prior PPI were included. Baseline clinical, echocardiographic, and angiographic characteristics, procedural and post-procedural details were collected. RESULTS: The incidence of PPI after early-generation self-expanding valves in this BAV cohort was 26.3%. Baseline characteristics were comparable between patients requiring PPI post-TAVR or not. Perimeter oversizing greater than 20% significantly increased the risk of PPI compared with an oversizing of 10-20% (OR 5.08 [1.22, 21.07], P = 0.03). The proportion of patients with a depth of implantation greater than 6 mm was significantly higher in those who required PPI (82.4% vs 54.3%, P = 0.04). When testing the impact of depth of implantation >6 mm and oversizing in different morphologies, only in type 1 bicuspid patients and by oversizing>20% increased the risk of PPI (OR 12.00 [1.25, 115.36], P = 0.03) compared with an oversizing of 10-20%. CONCLUSIONS: Excessive perimeter oversizing in relation to aortic annulus and depth of implantation greater than 6 mm should be avoided to improve PPI post-TAVR for BAV patients receiving self-expanding devices, especially for type 1 BAV.


Assuntos
Valva Aórtica/anormalidades , Arritmias Cardíacas/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Marca-Passo Artificial/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Arritmias Cardíacas/etiologia , Doença da Válvula Aórtica Bicúspide , Feminino , Humanos , Incidência , Masculino , Tomografia Computadorizada Multidetectores , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
10.
J Thromb Thrombolysis ; 45(3): 463-465, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29478129

RESUMO

The imaging finding of hypo-attenuated leaflet thickening (HALT) on bioprosthesis after transcatheter aortic valve replacement (TAVR) has been reported. The underlying mechanism is not clear, but leaflet thrombosis is speculated to be the cause. Heterogeneous antiplatelet responses may play a role in the process. This is a prospective, single-center pilot study in patients who received successful TAVR from June 2012 to November 2016. HALT on post-procedural multi-detector computed tomography. We thoroughly genotyped 34 SNPs and 8 SNPs that have been reported for clopidogrel and aspirin resistance. A total of 148 patients were enrolled. There were 15 patients demonstrating signs of HALT. Patients with HALT had a higher rate of atrial fibrillation (AF) pre-TAVR (33.3 vs. 7.5%, P = 0.01). We found that rs4244285 G>A polymorphism of the CYP2C19 gene was associated with the risk of HALT in the overdominant model (OR 4.00 [1.15-13.97], P = 0.02 for GA vs. GG+AA) adjusted by sex and the presence of pre-TAVR AF. Antiplatelet drug resistance is a reasonable possibility involved in HALT. Potential directions were suggested in polymorphisms of the CYP2C19 gene.


Assuntos
Inibidores da Agregação Plaquetária/uso terapêutico , Polimorfismo de Nucleotídeo Único , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Aspirina/farmacologia , Aspirina/uso terapêutico , Clopidogrel , Citocromo P-450 CYP2C19/genética , Resistência a Medicamentos/genética , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Masculino , Projetos Piloto , Estudos Prospectivos , Ticlopidina/análogos & derivados , Ticlopidina/farmacologia , Ticlopidina/uso terapêutico
11.
Heart Lung Circ ; 27(4): e46-e50, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29198572

RESUMO

Bioprosthesis thrombosis after transcatheter aortic valve replacement (TAVR) raised concerns about further clinical events. We report the case of a patient who suffered acute myocardial infarction (AMI) after TAVR for 3 years. Thrombosis was confirmed in the right coronary sinus of Valsalva by transthoracic echocardiography. Coronary angiography demonstrated the ostium of the right coronary artery was occluded. As an attempt to perform percutaneous coronary intervention (PCI) was unsuccessful, long-term therapeutic anticoagulation with warfarin was undertaken. Within 2 weeks, symptoms were relieved, and the right coronary ostium thrombus disappeared on computed tomography (CT) angiography. This case highlights the AMI as initial manifestation of delayed bioprosthesis thrombosis and the importance of anticoagulation against the bioprosthesis thrombosis. Meanwhile, the difficulty of PCI after TAVR is not only the stent frame of bioprosthesis, but also the location of the thrombosis.


Assuntos
Bioprótese/efeitos adversos , Cardiopatias/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/etiologia , Trombose/complicações , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Eletrocardiografia , Cardiopatias/diagnóstico , Cardiopatias/terapia , Humanos , Masculino , Intervenção Coronária Percutânea/métodos , Falha de Prótese , Reoperação , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Terapia Trombolítica , Trombose/diagnóstico
12.
Physiol Mol Biol Plants ; 24(3): 349-358, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29692543

RESUMO

The phytohomorne methyl jasmonate (MeJA) is known to trigger extensive reprogramming of gene expression leading to transcriptional activation of many secondary metabolic pathways. However, natural rubber is a commercially important secondary metabolite and little is known about the genetic and genomic basis of jasmonate-elicited rubber biosynthesis in rubber tree (Hevea brasiliensis). RNA sequencing (RNA-seq) of H. brasiliensis bark treated with 1 g lanolin paste containing 0.02% w/w MeJA for 24 h (M2) and 0.04% w/w MeJA for 24 h (M4) was performed. A total of 2950 and 2850 differentially expressed genes in M2 and M4 compared with control (C) were respectively detected. Key genes involved in 2-C-methyl-D-erythritol 4-phosphate, rubber biosynthesis, glycolysis and carbon fixation (Calvin cycle) pathway were found to be up-regulated by MeJA treatment. Particularly, the expression of 3-hydroxy-3-metylglutaryl coenzyme A reductase in MVA pathway was down-regulated by MeJA treatment, but the expression of farnesyl diphosphate synthase (FPS) and cis-prenyltransferase (CPT, or rubber transferase) in rubber biosynthesis pathway were up-regulated by MeJA treatment. Up-regulation of critical genes in JA biosynthesis in response to MeJA treatment exhibited the self-activation of JA biosynthesis. In addition, up-regulated genes of great regulatory importance in cross-talk between JA and other hormone signaling, and of transcriptional regulation were identified. The increased expression levels of FPS and CPT in rubber biosynthesis pathway possibly resulted in an increased latex production in rubber tree treated with MeJA. The present results provide insights into the mechanism by which MeJA activates the rubber biosynthesis and the transcriptome data can also serve as the foundation for future research into the molecular basis for MeJA regulation of other cellular processes.

13.
Catheter Cardiovasc Interv ; 89(S1): 528-533, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28318133

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has been demonstrated to be an effective alternative to surgical aortic valve replacement (SAVR) in patients with aortic stenosis who are deemed high risk or inoperable. Currently, TAVI procedures in China mostly make use of the domestic Venus A-Valve and the CoreValve; however, there is no data on their comparative performance. METHODS: Consecutive patients undergoing TAVI with the aforementioned devices were included. The outcomes were reported according to the Valve Academic Research Consortium-2 (VARC) definitions. RESULTS: A total of 54 TAVI procedures were performed, 27 with the CoreValve and the other 27 with the Venus A-Valve. An additional valve was required in 4 (14.8%) and 3 (11.1%) patients, and the VARC-2 device success rates were 81.5 and 85.2%, respectively. The incidences of common complications were similar, except for the significantly less frequent pacemaker insertion in the Venus A-Valve group (7.4 vs. 37.0%, P = 0.03). Within 30 days, 2 (3.7%) patients died, 1 in each group, and both had a bicuspid aortic valve (BAV). No other serious complications, such as annular rupture, coronary obstruction and aortic dissection, occurred in the 32 BAV patients treated with the Venus A-Valve (14) or the CoreValve (18). After 2-years of follow-up, there was no significant difference between CoreValve group and Venus-A group (11.1 vs. 7.4%, P = 0.64). CONCLUSION: TAVI with the domestic Venus A-Valve is feasible, safe, and can produce favorable short-term outcomes comparable to those with the CoreValve in inoperable or high-risk patients with tricuspid and bicuspid aortic valve stenosis. © 2017 Wiley Periodicals, Inc.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidade , China , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento
14.
BMC Genomics ; 17: 257, 2016 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-27008913

RESUMO

BACKGROUND: Rubber tree (Hevea brasiliensis) is an important industrial crop cultivated in tropical areas for natural rubber production. Treatment of the bark of rubber trees with ehephon (an ethylene releaser) has been a routine measure to increase latex yield, but the molecular mechanism behind the stimulation of rubber production by ethylene still remains a puzzle. Deciphering the enigma is of great importance for improvement of rubber tree for high yield. RESULTS: De novo sequencing and assembly of the bark transciptomes of Hevea brasiliensis induced with ethephon for 8 h (E8) and 24 h (E24) were performed. 51,965,770, 52,303,714 and 53,177,976 high-quality clean reads from E8, E24 and C (control) samples were assembled into 81,335, 80,048 and 80,800 unigenes respectively, with a total of 84,425 unigenes and an average length of 1,101 bp generated. 10,216 and 9,374 differentially expressed genes (DEGs) in E8 and E24 compared with C were respectively detected. The expression of several enzymes in crucial points of regulation in glycolysis were up-regulated and DEGs were not significantly enriched in isopentenyl diphosphate (IPP) biosynthesis pathway. In addition, up-regulated genes of great regulatory importance in carbon fixation (Calvin cycle) were identified. CONCLUSIONS: The rapid acceleration of glycolytic pathway supplying precursors for the biosynthesis of IPP and natural rubber, instead of rubber biosynthesis per se, may be responsible for ethylene stimulation of latex yield in rubber tree. The elevated rate of flux throughout the Calvin cycle may account for some durability of ethylene-induced stimulation. Our finding lays the foundations for molecular diagnostic and genetic engineering for high-yielding improvement of rubber tree.


Assuntos
Etilenos/farmacologia , Hevea/metabolismo , Látex/biossíntese , Compostos Organofosforados/farmacologia , Transcriptoma , Perfilação da Expressão Gênica , Regulação da Expressão Gênica de Plantas , Biblioteca Gênica , Hevea/genética , Redes e Vias Metabólicas , Anotação de Sequência Molecular , Casca de Planta/genética , Casca de Planta/metabolismo , RNA de Plantas/genética , Análise de Sequência de RNA
15.
Cardiovasc Diabetol ; 15(1): 106, 2016 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-27484994

RESUMO

OBJECTIVE: We try to analyse the effect of renal functions on death in CAD patients with different body compositions. METHODS: A retrospective analysis was conducted in 2989 consecutive patients with CAD confirmed by coronary angiography were enrolled and were grouped into two categories: basically preserved renal function (PRF) (eGFR ≥60 ml/min) and obviously reduced renal function (RRF) (eGFR <60 ml/min). The influence of renal insufficiency on mortality of CAD was detected in every tertile of body composition, including body mass index (BMI), body fat (BF) and lean mass index (LMI). The end points were all-cause mortality. RESULTS: The mean follow-up time was 29.1 ± 12.5 months and death events occurred in 271 cases. The percentage of patients with RRF was positively correlated with BF and inversely correlated with the LMI, but no relationship to BMI. The survival curves showed that the risk of death was significantly higher in the RRF patients in all subgroups stratified using BMI, BF, or LMI (log rank test, all p < 0.001). The COX multivariate regression analysis showed that the risk of death was significantly higher in the RRF patients with high BF (HR 1.95, CI 1.25-3.05) and low LMI (HR 1.82, CI 1.19-2.79). Meanwhile, risk of death was significantly higher in RRF patients with a high BMI (HR 2.08, CI 1.22-3.55) or low BMI (HR 1.98, CI 1.28-3.08) but this risk was not significant in patients with a medium BMI (HR 1.12, 0.65-1.94). The subgroup analysis of patients with acute coronary syndrome (ACS) showed similar results. CONCLUSIONS: For patients with CAD, renal insufficiency was positively correlated with BF, inversely correlated with LMI, and unrelated to BMI. The effect of renal insufficiency on the risk of death of CAD was related to body composition.


Assuntos
Composição Corporal/fisiologia , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico , Rim/fisiopatologia , Obesidade/complicações , Adulto , Idoso , Índice de Massa Corporal , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/diagnóstico , Prognóstico , Estudos Retrospectivos
16.
Catheter Cardiovasc Interv ; 87 Suppl 1: 570-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26856312

RESUMO

OBJECTIVE: The present study was performed to investigate the relationship between chronic obstructive pulmonary disease (COPD) and transcatheter aortic valve implantation (TAVI). BACKGROUND: Controversies regarding the relationship between COPD and TAVI have intensified. METHODS: A literature review of the PubMed online database was performed, and articles published between January 1, 2002 and March 20, 2015 were analyzed. Random-effect and fixed-effect models were used, depending on the between-study heterogeneity. RESULTS: A total of 28 studies, involving 51,530 patients, were identified in our review. The burden of COPD ranged from 12.5% to 43.4%, and COPD negatively impacted both short-term and long-term all-cause survival (30 days: odds ratio [OR], 1.43, 95% CI, 1.14-1.79; >2 years: hazard ratio [HR], 1.34, 95% CI, 1.12-1.61). COPD was also associated with increased short-term and mid-term cardiac-cause mortality (30 days: OR, 1.29, 95% CI, 1.02-1.64; 1 year: HR: 1.09, 1.02-1.17). Moreover, COPD (OR, 1.97, 95% CI, 1.29-3.0) predicted post-TAVI acute kidney disease. Importantly, chronic kidney disease (CKD) (HR, 1.2, 95% CI, 1.1-1.32) and the distance of the 6 minute walk test (6MWT) (HR, 1.16, 1.06-1.27) predicted TAVI futility in patients with COPD. CONCLUSION: COPD is common among patients undergoing TAVI, and COPD impacts both short- and long-term survival. COPD patients, who had a lower BMI, shorter distance of 6MWT and CKD, were at higher risk for TAVI futility.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Injúria Renal Aguda/epidemiologia , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Índice de Massa Corporal , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Distribuição de Qui-Quadrado , Comorbidade , Teste de Esforço , Tolerância ao Exercício , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Modelos Logísticos , Pulmão/fisiopatologia , Masculino , Análise Multivariada , Razão de Chances , Prevalência , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/mortalidade , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Insuficiência Renal Crônica/epidemiologia , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Caminhada
17.
BMC Genomics ; 16: 398, 2015 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-25994052

RESUMO

BACKGROUND: Tapping panel dryness (TPD) involves in the partial or complete cessation of latex flow thus seriously affect latex production in rubber tree (Hevea brasiliensis). Numerous studies have been conducted to define its origin and nature, but the molecular nature and mechanism of TPD occurrence remains unknown. This study is committed to de novo sequencing and comparative analysis of the transcriptomes of healthy (H) and TPD-affected (T) rubber trees to identify the genes and pathways related to the TPD. RESULTS: Total raw reads of 34,632,012 and 35,913,020 bp were obtained from H and T library, respectively using Illumina Hiseq 2000 sequencing technology. De novo assemblies yielded 141,456 and 169,285 contigs, and 96,070 and 112,243 unigenes from H and T library, respectively. Among 73597 genes, 22577 genes were identified as differential expressed genes between H and T library via comparative transcript profiling. A majority of genes involved in natural rubber biosynthesis and jasmonate synthesis with most potential relevance in TPD occurrence were found to be differentially expressed. CONCLUSIONS: In TPD-affected trees, the expression of most genes related to the latex biosynthesis and jasmonate synthesis was severely inhibited and is probably the direct cause of the TPD. These new de novo transcriptome data sets provide a significant resource for the discovery of genes related to TPD and improve our understanding of the occurrence and maintainace of TPD.


Assuntos
Ciclopentanos/metabolismo , Perfilação da Expressão Gênica/métodos , Hevea/metabolismo , Oxilipinas/metabolismo , Borracha/metabolismo , Análise de Sequência de RNA/métodos , Regulação da Expressão Gênica de Plantas , Hevea/genética , Doenças das Plantas/genética , Proteínas de Plantas/genética , Proteínas de Plantas/metabolismo , RNA Mensageiro/análise , RNA de Plantas/análise
18.
Head Neck ; 46(8): 1975-1987, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38348564

RESUMO

BACKGROUND: The preservation of parathyroid glands is crucial in endoscopic thyroid surgery to prevent hypocalcemia and related complications. However, current methods for identifying and protecting these glands have limitations. We propose a novel technique that has the potential to improve the safety and efficacy of endoscopic thyroid surgery. PURPOSE: Our study aims to develop a deep learning model called PTAIR 2.0 (Parathyroid gland Artificial Intelligence Recognition) to enhance parathyroid gland recognition during endoscopic thyroidectomy. We compare its performance against traditional surgeon-based identification methods. MATERIALS AND METHODS: Parathyroid tissues were annotated in 32 428 images extracted from 838 endoscopic thyroidectomy videos, forming the internal training cohort. An external validation cohort comprised 54 full-length videos. Six candidate algorithms were evaluated to select the optimal one. We assessed the model's performance in terms of initial recognition time, identification duration, and recognition rate and compared it with the performance of surgeons. RESULTS: Utilizing the YOLOX algorithm, we developed PTAIR 2.0, which demonstrated superior performance with an AP50 score of 92.1%. The YOLOX algorithm achieved a frame rate of 25.14 Hz, meeting real-time requirements. In the internal training cohort, PTAIR 2.0 achieved AP50 values of 94.1%, 98.9%, and 92.1% for parathyroid gland early prediction, identification, and ischemia alert, respectively. Additionally, in the external validation cohort, PTAIR outperformed both junior and senior surgeons in identifying and tracking parathyroid glands (p < 0.001). CONCLUSION: The AI-driven PTAIR 2.0 model significantly outperforms both senior and junior surgeons in parathyroid gland identification and ischemia alert during endoscopic thyroid surgery, offering potential for enhanced surgical precision and patient outcomes.


Assuntos
Endoscopia , Glândulas Paratireoides , Tireoidectomia , Humanos , Tireoidectomia/efeitos adversos , Tireoidectomia/métodos , Endoscopia/métodos , Endoscopia/efeitos adversos , Glândulas Paratireoides/cirurgia , Algoritmos , Aprendizado Profundo , Inteligência Artificial , Hipocalcemia/prevenção & controle , Hipocalcemia/etiologia , Feminino , Masculino
19.
Zhonghua Nan Ke Xue ; 19(11): 984-7, 2013 Nov.
Artigo em Zh | MEDLINE | ID: mdl-24341090

RESUMO

OBJECTIVE: To review the clinical characteristics and treatment strategies of Fournier's gangrene in HIV-positive patients. METHODS: We retrospectively analyzed the clinical characteristics and therapeutic methods of 29 HIV-positive cases of Fournier's gangrene. RESULTS: The patients were aged 21-81 (mean 34.2) years, 27 < or = 47 years and the other two 79 and 81 years old, respectively. All the patients were HIV positive and diagnosed as having Fournier's gangrene, with CD4+ T lymphocyte count < 320/mm3, and none had received any antiretroviral therapy. The two aged patients were complicated by diabetes mellitus. All the cases originated in scrotal or penile infection, with later involvement of the surrounding skin soft tissues. Aggressive surgical debridement, incision-drainage and broad-spectrum antibiotic medication were initiated right after admission, and scrotoplasty was performed for 4 cases. Twenty-six of the patients were recovered and the other 3 (10.3%) died after surgery, 1 from infectious shock and 2 from diabetes mellitus complicated by pulmonary infection and renal failure. CONCLUSION: Timely aggressive surgical debridement, incision-drainage and broad-spectrum antibiotic medication are essential for the treatment of Fournier's gangrene in HIV-positive patients. We did not find any direct adverse impact of HIV infection on the prognosis of Fournier's gangrene.


Assuntos
Gangrena de Fournier/cirurgia , Infecções por HIV/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/uso terapêutico , Desbridamento , Gangrena de Fournier/complicações , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Escroto/cirurgia , Adulto Jovem
20.
J Clin Med ; 12(15)2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37568469

RESUMO

The snare-assisted technique has been described to facilitate transcatheter aortic valve replacement (TAVR) delivery system advancement in complex aortic anatomies. However, the evidence is limited to case reports. To evaluate the safety profile of the snare-facilitated approach and its impact on self-expanding (SE) TAVR outcomes, we collected consecutive patients who underwent transfemoral SE-TAVR for aortic stenosis, using propensity score matching (PSM) separately in tricuspid and type-0 and type-1 bicuspid aortic valve morphology between the snare and non-snare groups. In 766 patients, despite the snare group having significantly larger annulus angulation and maximal ascending aortic diameter, both groups achieved comparable 30-day device success rates, regardless of first-generation or new-generation valve use. After PSM, the snare group had a significantly lower new permanent pacemaker implantation rate among 193 type-0 patients (3.3% vs. 18.3%, p = 0.01). The ipsilateral group used new-generation valves less frequently (23.0% vs. 75.4%, p < 0.001), but there were no significant inter-group differences in procedure-related events, except for a lower incidence of PVL ≥ mild in the ipsilateral group (14.9% vs. 32.3%, p = 0.01). In conclusion, the snare-assisted technique appears useful in SE-TAVR with angulated aortic root anatomy, and the benefits were comparable between ipsilateral and contralateral snare techniques.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA