Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 172
Filtrar
1.
Eur Heart J ; 43(28): 2672-2684, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35608227

RESUMO

Congenital heart disease (CHD) is often comprised of complex three-dimensional (3D) anatomy that must be well understood to assess the pathophysiological consequences and guide therapy. Thus, detailed cardiac imaging for early detection and planning of interventional and/or surgical treatment is paramount. Advanced technologies have revolutionized diagnostic and therapeutic practice in CHD, thus playing an increasing role in its management. Traditional reliance on standard imaging modalities including echocardiography, cardiac computed tomography (CT) and magnetic resonance imaging (MRI) has been augmented by the use of recent technologies such as 3D printing, virtual reality, augmented reality, computational modelling, and artificial intelligence because of insufficient information available with these standard imaging techniques. This has created potential opportunities of incorporating these technologies into routine clinical practice to achieve the best outcomes through delivery of personalized medicine. In this review, we provide an overview of these evolving technologies and a new approach enabling physicians to better understand their real-world application in adult CHD as a prelude to clinical workflow implementation.


Assuntos
Cardiopatias Congênitas , Realidade Virtual , Adulto , Inteligência Artificial , Coração , Cardiopatias Congênitas/cirurgia , Humanos , Impressão Tridimensional
2.
Curr Opin Cardiol ; 36(5): 495-504, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34261882

RESUMO

PURPOSE OF REVIEW: Despite the prevalence of tricuspid valve regurgitation disorders, isolated interventions on tricuspid valves were previously infrequent due to high mortality rates and lack of advanced clinical imaging technology. Due to advancements in cardiovascular imaging and interventional technologies tricuspid valve repairs and replacement interventions became increasingly more attainable. RECENT FINDINGS: Noninvasive clinical imaging of the tricuspid valve can be challenging, providing anincomplete assessment of unique tricuspid anatomy. 3D printing technology represents an additional tool for more comprehensive preprocedural planning of tricuspid interventions and observation of tricuspid valve geometry. Patient-specific 3D printed replicas of tricuspid valve apparatus are especially useful in highly complicated cases, where physiological tricuspid replicas allow benchtop observation of individual patient's anatomy, device implantation in physiological tricuspid valves and interactions of devices with native tricuspid tissue, frequently leading to optimization or change in operational strategy. SUMMARY: Comprehensive use of clinical imaging including echocardiography, computed tomography, and cardiac magnetic resonance along with 3D printed modeling is key to successful tricuspid repair and replacements. Patient-specific 3D printed models of tricuspid anatomy can facilitate preprocedural planning, educate patients and clinicians, and improve device design, leading to the overall improvement of patients' outcomes and care.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Ecocardiografia , Humanos , Impressão Tridimensional , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
3.
Catheter Cardiovasc Interv ; 97(2): 361-364, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32141679

RESUMO

While transcatheter valve-in-valve (ViV) implantation may reduce the number of lifetime surgical reinterventions in some patients with congenital heart disease, in other patients the bioprosthetic valve ring can lead to patient-prosthesis mismatch due to reduction of internal diameter if a transcatheter valve is implanted. A 49-year-old woman with multiple prior cardiac surgeries presented with heart failure due to bioprosthetic tricuspid valve stenosis. Initial predilation valvuloplasty suggested conventional ViV implant would produce patient-prosthesis mismatch, therefore, we intentionally fractured the bioprosthetic valve ring to facilitate optimal hemodynamics with implantation of a 29 mm transcatheter valve.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia
4.
Curr Opin Cardiol ; 35(5): 482-490, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32649354

RESUMO

PURPOSE OF REVIEW: This article aims to review recent landmark clinical trials that have resulted in a paradigm shift in the management of patients with mitral regurgitation. This article additionally highlights the instrumental role that structural heart disease (SHD) imaging plays in evaluation of mitral regurgitation and determining candidacy for transcatheter mitral valve repair (TMVr), in addition to the procedural guidance and detection of complications. RECENT FINDINGS: Edge-to-edge TMVr with the MitraClip device (Abbott Vascular, Santa Clara, California) was initially studied and subsequently approved by the US Food and Drug Administration (FDA) for treatment of primary mitral regurgitation in 2013. After the publication of a landmark clinical trial in 2018, the indications have been expanded and FDA has subsequently, in 2019, approved TMVr for patients with functional mitral regurgitation. This has been paralleled by advances in cardiac imaging with more emphasis on the role of SHD imagers as a part of the heart team. SUMMARY: TMVr has revolutionized the management of mitral regurgitation and relies heavily on SHD imaging to ensure optimal outcomes.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
5.
J Cardiovasc Magn Reson ; 22(1): 55, 2020 07 30.
Artigo em Inglês | MEDLINE | ID: mdl-32727590

RESUMO

BACKGROUND: A comprehensive non-invasive evaluation of bioprosthetic mitral valve (BMV) function can be challenging. We describe a novel method to assess BMV effective orifice area (EOA) based on phase contrast (PC) cardiovascular magnetic resonance (CMR) data. We compare the performance of this new method to Doppler and in vitro reference standards. METHODS: Four sizes of normal BMVs (27, 29, 31, 33 mm) and 4 stenotic BMVs (27 mm and 29 mm, with mild or severe leaflet obstruction) were evaluated using a CMR- compatible flow loop. BMVs were evaluated with PC-CMR and Doppler methods under flow conditions of; 70 mL, 90 mL and 110 mL/beat (n = 24). PC-EOA was calculated as PC-CMR flow volume divided by the PC- time velocity integral (TVI). RESULTS: PC-CMR measurements of the diastolic peak velocity and TVI correlated strongly with Doppler values (r = 0.99, P < 0.001 and r = 0.99, P < 0.001, respectively). Across all conditions tested, the Doppler and PC-CMR measurement of EOA (1.4 ± 0.5 vs 1.5 ± 0.7 cm2, respectively) correlated highly (r = 0.99, P < 0.001), with a minimum bias of 0.13 cm2, and narrow limits of agreement (- 0.2 to 0.5 cm2). CONCLUSION: We describe a novel method to assess BMV function based on PC measures of transvalvular flow volume and velocity integration. PC-CMR methods can be used to accurately measure EOA for both normal and stenotic BMV's and may provide an important new parameter of BMV function when Doppler methods are unobtainable or unreliable.


Assuntos
Bioprótese , Ecocardiografia Doppler em Cores , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Hemodinâmica , Imageamento por Ressonância Magnética , Estenose da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Estudos de Viabilidade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Estenose da Valva Mitral/fisiopatologia , Estenose da Valva Mitral/cirurgia , Variações Dependentes do Observador , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes
6.
Echocardiography ; 37(6): 945-953, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32453888

RESUMO

BACKGROUND: Transcatheter mitral valve replacement technologies have been developed to treat a wide range of mitral valve pathologies including primary and secondary mitral regurgitation, mitral stenosis, in addition to degenerative bioprosthetic valves and failed annuloplasty rings. OBJECTIVE: Transesophageal echocardiography, particularly with use of 3-dimensional imaging is key in successfully guiding these interventions. In this review, we highlight the key role of 3D transesophageal echocardiography in guiding TMVR, including valve-in-native valve, valve-in-prosthetic valve, valve-in-prosthetic ring, and valve-in-mitral annular calcification interventions.


Assuntos
Ecocardiografia Tridimensional , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Desenho de Prótese , Resultado do Tratamento
7.
Circulation ; 137(24): 2557-2567, 2018 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-29530883

RESUMO

BACKGROUND: Comparative echocardiographic data on transcatheter aortic valve replacement systems from randomized trials are limited. The REPRISE III trial (Repositionable Percutaneous Replacement of Stenotic Aortic Valve through Implantation of Lotus Valve System - Randomized Clinical Evaluation) is a multicenter, randomized comparison of a mechanically expanded (Lotus) versus self-expanding (CoreValve) transcatheter aortic valve replacement device. This analysis rigorously assesses Doppler-derived valve hemodynamics and the impact on outcomes at 1 year in patients with extreme/high surgical risk treated with Lotus and CoreValve from REPRISE III. METHODS: REPRISE III includes patients with extreme- and high-risk aortic stenosis. Patients were enrolled at 55 centers. All transthoracic echocardiograms with Doppler were obtained following a standard protocol up to 12 months postimplant and analyzed by a core laboratory. Valve size, mean gradient, aortic valve area, and Doppler velocity index and their impact on clinical outcomes are reported. Additional parameters including paravalvular leak were evaluated using a multiparametric approach. RESULTS: A total of 912 patients were randomly assigned (2:1 ratio; 607 Lotus:305 CoreValve). Median age was 84 years, 51% of the patients were women, and the Society of Thoracic Surgeons score was 6.8±4.1. CoreValve demonstrated lower gradients and larger aortic valve area and Doppler velocity index than Lotus at discharge; the difference decreased in subsequent follow-up up to a year (all P<0.01). Lotus had lower rates of paravalvular leak that persisted over time (P<0.05). Similar outcomes were seen when comparing each valve type by size group (small, medium, large). The hemodynamic differences between valves did not translate into worse clinical outcomes. All-cause mortality was not different between the 2 groups in any of the 3 valve sizes. When comparing patients with normal valve gradients (<20 mm Hg, n=780) with those with abnormal gradients (>20 mm Hg, n=48) in the entire patient population, all-cause mortality was not different. This was also not significant when evaluating each valve type separately. Similarly, there were no differences for aortic valve area >1.1 cm2 or <1.1 cm2 and for Doppler velocity index >0.35 or <0.35 (all P=not significant). CONCLUSIONS: Lotus had significantly greater freedom from moderate or severe paravalvular leak and smaller valve area and higher gradients than CoreValve. The hemodynamic differences were not associated with any clinical differences in the composite end point of mortality, disabling stroke, and moderate paravalvular leak or with quality of life at 1 year of follow-up. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02202434.


Assuntos
Estenose da Valva Aórtica , Ecocardiografia , Hemodinâmica , Qualidade de Vida , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/terapia , Feminino , Seguimentos , Humanos , Masculino , Estudos Prospectivos
8.
Catheter Cardiovasc Interv ; 94(1): 3-26, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31002751
9.
JACC Cardiovasc Imaging ; 17(4): 428-440, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38569793

RESUMO

Structural heart disease interventions rely heavily on preprocedural planning and simulation to improve procedural outcomes and predict and prevent potential procedural complications. Modeling technologies, namely 3-dimensional (3D) printing and computational modeling, are nowadays increasingly used to predict the interaction between cardiac anatomy and implantable devices. Such models play a role in patient education, operator training, procedural simulation, and appropriate device selection. However, current modeling is often limited by the replication of a single static configuration within a dynamic cardiac cycle. Recognizing that health systems may face technical and economic limitations to the creation of "in-house" 3D-printed models, structural heart teams are pivoting to the use of computational software for modeling purposes.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias , Humanos , Valor Preditivo dos Testes , Procedimentos Cirúrgicos Cardíacos/métodos , Simulação por Computador , Cardiopatias/diagnóstico por imagem , Cardiopatias/terapia , Software , Impressão Tridimensional
10.
J Am Heart Assoc ; 13(5): e032784, 2024 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-38390821

RESUMO

BACKGROUND: Prior studies investigating the impact of residual mitral regurgitation (MR), tricuspid regurgitation (TR), and elevated predischarge transmitral mean pressure gradient (TMPG) on outcomes after mitral transcatheter edge-to-edge repair (TEER) have assessed each parameter in isolation. We sought to examine the prognostic value of combining predischarge MR, TR, and TMPG to study long-term outcomes after TEER. METHODS AND RESULTS: We reviewed the records of 291 patients who underwent successful mitral TEER at our institution between March 2014 and June 2022. Using well-established outcomes-related cutoffs for predischarge MR (≥moderate), TR (≥moderate), and TMPG (≥5 mm Hg), 3 echo profiles were developed based on the number of risk factors present (optimal: 0 risk factors, mixed: 1 risk factor, poor: ≥2 risk factors). Discrimination of the profiles for predicting the primary composite end point of all-cause mortality and heart failure hospitalization at 2 years was examined using Cox regression. Overall, mean age was 76.7±10.6 years, 43.3% were women, and 53% had primary MR. Two-year event-free survival was 61%. Predischarge TR≥moderate, MR≥moderate, and TMPG≥5 mm Hg were risk factors associated with the primary end point. Compared with the optimal profile, there was an incremental risk in 2-year event-rate with each worsening profile (optimal as reference; mixed profile: hazard ratio (HR), 2.87 [95% CI, 1.71-5.17], P<0.001; poor profile: HR, 3.76 [95% CI, 1.84-6.53], P<0.001). Echocardiographic profile was statistically associated with the 2-year mortality end point (optimal as reference; mixed profile: HR, 3.55 [95% CI, 1.81-5.96], P<0.001; poor profile: HR, 3.39 [95% CI, 2.56-7.33], P=0.02). CONCLUSIONS: The echocardiographic profile integrating predischarge TR, MR, and TMPG presents a novel prognostic stratification tool for patients undergoing mitral TEER.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Mercúrio , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Idoso de 80 Anos ou mais , Masculino , Ecocardiografia , Instalações de Saúde , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Cardíaco
11.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38710669

RESUMO

OBJECTIVES: The objective of this analysis was to assess the normal haemodynamic performance of contemporary surgical aortic valves at 1 year postimplant in patients undergoing surgical aortic valve replacement for significant valvular dysfunction. By pooling data from 4 multicentre studies, this study will contribute to a better understanding of the effectiveness of surgical aortic valve replacement procedures, aiding clinicians and researchers in making informed decisions regarding valve selection and patient management. METHODS: Echocardiograms were assessed by a single core laboratory. Effective orifice area, dimensionless velocity index, mean aortic gradient, peak aortic velocity and stroke volume were evaluated. RESULTS: The cohort included 2958 patients. Baseline age in the studies ranged from 70.1 ± 9.0 to 83.3 ± 6.4 years, and Society of Thoracic Surgeons risk of mortality was 1.9 ± 0.7 to 7.5 ± 3.4%. Twenty patients who had received a valve model implanted in fewer than 10 cases were excluded. Ten valve models (all tissue valves; n = 2938 patients) were analysed. At 1 year, population mean effective orifice area ranged from 1.46 ± 0.34 to 2.12 ± 0.59 cm2, and dimensionless velocity index, from 0.39 ± 0.07 to 0.56 ± 0.15. The mean gradient ranged from 8.6 ± 3.4 to 16.1 ± 6.2 mmHg with peak aortic velocity of 1.96 ± 0.39 to 2.65 ± 0.47 m/s. Stroke volume was 75.3 ± 19.6 to 89.8 ± 24.3 ml. CONCLUSIONS: This pooled cohort is the largest to date of contemporary surgical aortic valves with echocardiograms analysed by a single core lab. Overall haemodynamic performance at 1 year ranged from good to excellent. These data can serve as a benchmark for other studies and may be useful to evaluate the performance of bioprosthetic surgical valves over time. CLINICAL TRIAL REGISTRATION NUMBER: NCT02088554, NCT02701283, NCT01586910 and NCT01531374.


Assuntos
Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Hemodinâmica , Humanos , Hemodinâmica/fisiologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Idoso , Feminino , Masculino , Idoso de 80 Anos ou mais , Implante de Prótese de Valva Cardíaca/métodos , Ecocardiografia , Pessoa de Meia-Idade , Desenho de Prótese
12.
J Am Heart Assoc ; 13(11): e033447, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38780160

RESUMO

BACKGROUND: Coronary microvascular function and hemodynamics may play a role in coronary circulation and myocardial remodeling in patients with aortic stenosis (AS). We aimed to evaluate the relationship between myocardial blood flow and myocardial function in patients with AS, no AS, and aortic valve sclerosis. METHODS AND RESULTS: We included consecutive patients who had resting transthoracic echocardiography and clinically indicated positron emission tomography myocardial perfusion imaging to capture their left ventricular ejection fraction, global longitudinal strain (GLS), and myocardial flow reserve (MFR). The primary outcome was major adverse cardiovascular event (all-cause mortality, myocardial infarction, or late revascularization). There were 2778 patients (208 with aortic sclerosis, 39 with prosthetic aortic valve, 2406 with no AS, and 54, 49, and 22 with mild, moderate, and severe AS, respectively). Increasing AS severity was associated with impaired MFR (P<0.001) and GLS (P<0.001), even when perfusion was normal. Statistically significant associations were noted between MFR and GLS, MFR and left ventricular ejection fraction, and MFR and left ventricular ejection fraction reserve. After a median follow-up of 349 (interquartile range, 116-662) days, 4 (7.4%), 5 (10.2%), and 6 (27.3%) patients experienced a major adverse cardiovascular event in the mild, moderate, and severe AS groups, respectively. In a matched-control analysis, patients with mild-to-moderate AS had higher rates of impaired MFR (52.9% versus 39.9%; P=0.048) and major adverse cardiovascular event (11.8% versus 3.0%; P=0.002). CONCLUSIONS: Despite lack of ischemia, as severity of AS increased, MFR decreased and GLS worsened, reflecting worse coronary microvascular health and myocardial remodeling. Positron emission tomography-derived MFR showed a significant independent correlation with left ventricular ejection fraction and GLS. Patients with prosthetic aortic valve showed a high prevalence of impaired MFR.


Assuntos
Estenose da Valva Aórtica , Reserva Fracionada de Fluxo Miocárdico , Microcirculação , Imagem de Perfusão do Miocárdio , Volume Sistólico , Função Ventricular Esquerda , Remodelação Ventricular , Humanos , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Feminino , Masculino , Remodelação Ventricular/fisiologia , Idoso , Função Ventricular Esquerda/fisiologia , Imagem de Perfusão do Miocárdio/métodos , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Volume Sistólico/fisiologia , Microcirculação/fisiologia , Circulação Coronária/fisiologia , Ecocardiografia , Índice de Gravidade de Doença , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Estudos Retrospectivos , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
13.
Curr Probl Cardiol ; 49(1 Pt A): 102042, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37595856

RESUMO

Data on the use of intracardiac echocardiography (ICE) guidance in mitral transcatheter edge-to-edge repair (mTEER) procedure is limited to case reports and small case series. Our study aims to assess the feasibility, safety, utilization patterns, and clinical outcomes of mTEER procedure with ICE guidance using a nationally representative real-world cohort of patients. This study used the National Inpatient Sample database from quarter 4 of 2015 to 2020. We used a propensity-matched analysis and adjusted odds ratios for in-hospital outcomes/complications. A P value of < 0.05 was considered significant. A total of 38,770 weighted cases of mTEER were identified. Of the included patients 665 patients underwent ICE-guided mTEER while 38,105 had TEE-guided mTEER. There were no differences in the in-hospital mortality between both groups (2.5% vs 3.0%, P = 0.58). Adjusted odds of in-hospital mortality (aOR 0.83, 95%CI [0.42-1.64]) were not significantly different. There were no differences in periprocedural complications including cardiac (aOR 0.85, 95%CI [0.54-1.35]), bleeding (aOR 1.45, 95%CI [0.93-2.33]), respiratory (aOR 0.88, 95%CI [0.61-1.25]), and renal (aOR 0.89, 95%CI [0.66-1.20]) complications between patients undergoing ICE-guided vs TEE-guided mTEER. There was no difference in GI complications between both groups (aOR 1.11, 95%CI [0.46-2.70]). The adjusted length of stay was less among ICE-guided mTEER (median: 1 vs 2, P < 0.01) with lower inflation-adjusted costs of hospitalization ($35,513 vs $47,067, P < 0.01). ICE-guided mTEER is safe when compared with TEE guided mTEER with no significant differences in in-hospital mortality, cardiac, bleeding, respiratory, and renal complications.


Assuntos
Ecocardiografia Transesofagiana , Pacientes Internados , Humanos , Ecocardiografia Transesofagiana/métodos , Estudos de Viabilidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Resultado do Tratamento
14.
J Am Heart Assoc ; 13(8): e033510, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38567665

RESUMO

BACKGROUND: Pulmonary hypertension (PH) and secondary mitral regurgitation (MR) are associated with adverse outcomes after mitral transcatheter edge-to-edge repair. We aim to study the prognostic value of invasively measured right ventricular afterload in patients undergoing mitral transcatheter edge-to-edge repair. METHODS AND RESULTS: We identified patients who underwent right heart catheterization ≤1 month before transcatheter edge-to-edge repair. The end points were all-cause mortality and a composite of mortality and heart failure hospitalization at 2 years. Using the receiver operating characteristic curve-derived threshold of 0.6 for pulmonary effective arterial elastance ([Ea], pulmonary artery systolic pressure/stroke volume), patients were stratified into 3 profiles based on PH severity (low elastance [HE]: Ea <0.6/mean pulmonary artery pressure (mPAP)) <35; High Elastance with No/Mild PH (HE-): Ea ≥0.6/mPAP <35; and HE with Moderate/Severe PH (HE+): Ea ≥0.6/mPAP ≥35) and MR pathogenesis (Primary MR [PMR])/low elastance, PMR/HE, and secondary MR). The association between this classification and clinical outcomes was examined using Cox regression. Among 114 patients included, 50.9% had PMR. Mean±SD age was 74.7±10.6 years. Patients with Ea ≥0.6 were more likely to have diabetes, atrial fibrillation, New York Heart Association III/IV status, and secondary MR (all P<0.05). Overall, 2-year cumulative survival was 71.1% and was lower in patients with secondary MR and mPAP ≥35. Compared with patients with low elastance, cumulative 2-year event-free survival was significantly lower in HE- and HE+ patients (85.5% versus 50.4% versus 41.0%, respectively, P=0.001). Also, cumulative 2-year event-free survival was significantly higher in patients with PMR/low elastance when compared with PMR/HE and patients with secondary mitral regurgitation (85.5% versus 55.5% versus 46.1%, respectively, P=0.005). CONCLUSIONS: Assessment of the preprocedural cardiopulmonary profile based on mPAP, MR pathogenesis, and Ea guides patient selection by identifying hemodynamic features that indicate likely benefit from mitral-transcatheter edge-to-edge repair in PH or lack thereof.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Prognóstico , Insuficiência da Valva Mitral/cirurgia , Hemodinâmica , Cateterismo Cardíaco/efeitos adversos , Artéria Pulmonar , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos
15.
Artigo em Inglês | MEDLINE | ID: mdl-38836574

RESUMO

Background: Increased left atrial pressure (LAP) has been associated with adverse outcomes after mitral transcatheter edge-to-edge repair (M-TEER). We sought to evaluate outcomes based on differences in post-procedural LAP measured after final clip deployment. Methods: We included consecutive patients who underwent M-TEER at our institution between 2014-2022 with LAP monitoring. Patients were stratified into 3 groups according to tertiles of post-TEER mean LAP. Outcomes were assessed using Kaplan-Meier analysis and Cox proportional hazard models. Results: We included 273 patients (mean age 76.8±10.8 years, 42.5% women, 78.4% Caucasian). The mean post-TEER LAP was 8.7±1.7 mmHg in tertile 1 (N=85), 14.4±1.6 mmHg in tertile 2 (N=95), and 21.9±3.8 mmHg in tertile 3 (N=93). In comparison with tertile 1, both tertiles 2 and 3 were associated with increased risk of all-cause mortality or heart failure hospitalization at 2 years (adjHR 2.27, 95% CI 1.25-4.12; and adjHR 3.00, 95% CI 1.59-5.64 respectively). Among patients with primary MR, higher LAP was associated with increased risk of 2-year all-cause mortality or heart failure hospitalization [tertile 2 vs. 1: adjHR 3.00, 95% CI 1.37-6.56; and tertile 3 vs. 1: adjHR 5.52, 95% CI 2.04-14.95). However, in patients with secondary MR, neither being in tertile 2 (adjHR 1.53; 95% CI 0.55-4.24), nor tertile 3 (adjHR 2.18; 95% CI 0.82-5.77) were associated with the composite outcome compared with tertile 1. Any degree of LAP reduction following M-TEER was associated with lower mortality or heart failure hospitalization compared with no LAP reduction (adjHR 0.59; 95% CI 0.39-0.88). Conclusions: Elevated LAP after M-TEER was associated with increased 2-year risk of mortality or heart failure hospitalization. Exploration of reasons for elevated LAP after M-TEER, and ways to lower it warrant further investigation.

16.
J Am Soc Echocardiogr ; 37(1): 2-63, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38182282

RESUMO

In patients with significant cardiac valvular disease, intervention with either valve repair or valve replacement may be inevitable. Although valve repair is frequently performed, especially for mitral and tricuspid regurgitation, valve replacement remains common, particularly in adults. Diagnostic methods are often needed to assess the function of the prosthesis. Echocardiography is the first-line method for noninvasive evaluation of prosthetic valve function. The transthoracic approach is complemented with two-dimensional and three-dimensional transesophageal echocardiography for further refinement of valve morphology and function when needed. More recently, advances in computed tomography and cardiac magnetic resonance have enhanced their roles in evaluating valvular heart disease. This document offers a review of the echocardiographic techniques used and provides recommendations and general guidelines for evaluation of prosthetic valve function on the basis of the scientific literature and consensus of a panel of experts. This guideline discusses the role of advanced imaging with transesophageal echocardiography, cardiac computed tomography, and cardiac magnetic resonance in evaluating prosthetic valve structure, function, and regurgitation. It replaces the 2009 American Society of Echocardiography guideline on prosthetic valves and complements the 2019 guideline on the evaluation of valvular regurgitation after percutaneous valve repair or replacement.


Assuntos
Doenças das Valvas Cardíacas , Coração , Adulto , Humanos , Imageamento por Ressonância Magnética , Ecocardiografia , Próteses e Implantes , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/cirurgia , Espectroscopia de Ressonância Magnética
17.
Artigo em Inglês | MEDLINE | ID: mdl-38795109

RESUMO

BACKGROUND: In patients with low-gradient aortic stenosis (AS) and low transvalvular flow, dobutamine stress echocardiography (DSE) is recommended to determine AS severity, whereas the degree of aortic valve calcification (AVC) supposedly correlates with AS severity according to current European and American guidelines. OBJECTIVES: The purpose of this study was to assess the relationship between AVC and AS severity as determined using echocardiography and DSE in patients with aortic valve area <1 cm2 and peak aortic valve velocity <4.0 m/s. METHODS: All patients underwent DSE to determine AS severity and multislice computed tomography to quantify AVC. Receiver-operating characteristics curve analysis was used to assess the diagnostic value of AVC for AS severity grading as determined using echocardiography and DSE in men and women. RESULTS: A total of 214 patients were included. Median age was 78 years (25th-75th percentile: 71-84 years) and 25% were women. Left ventricular ejection fraction was reduced (<50%) in 197 (92.1%) patients. Severe AS was diagnosed in 106 patients (49.5%). Moderate AS was diagnosed in 108 patients (50.5%; in 77 based on resting transthoracic echocardiography, in 31 confirmed using DSE). AVC score was high (≥2,000 for men or ≥1,200 for women) in 47 (44.3%) patients with severe AS and in 47 (43.5%) patients with moderate AS. AVC sensitivity was 44.3%, specificity was 56.5%, and positive and negative predictive values for severe AS were 50.0% and 50.8%, respectively. Area under the receiver-operating characteristics curve was 0.508 for men and 0.524 for women. CONCLUSIONS: Multi-slice computed tomography-derived AVC scores showed poor discrimination between grades of AS severity using DSE and cannot replace DSE in the diagnostic work-up of low-gradient severe AS.

18.
Curr Opin Cardiol ; 28(5): 518-23, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23817006

RESUMO

PURPOSE OF REVIEW: To review the current literature on prosthetic valve function and para-valvular regurgitation (PVR) after trans-catheter aortic valve replacement (TAVR). TAVR is a new alternative for the treatment of severe aortic stenosis in patients at high risk for surgical aortic valve replacement and nonsurgical candidates. RECENT FINDINGS: The innovations in three-dimensional trans-esophageal echocardiography have made it an integral part of the TAVR procedure. PVR is more frequent with TAVR than surgical aortic valve replacement and is associated with worse cardiovascular outcomes. Recent publications focus on echocardiographic techniques to better assess the structural components of aortic valve complex, and begin to define the mechanism and risks of PVR after TAVR. SUMMARY: Imaging innovations before, during, and after TAVR may lead to improved patient selection, accelerated development of TAVR prostheses, and ultimately a fuller characterization of the performance and potential limitations of a new generation of prosthetic heart valves.


Assuntos
Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/métodos , Complicações Pós-Operatórias/diagnóstico por imagem , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Procedimentos Endovasculares , Próteses Valvulares Cardíacas , Humanos , Falha de Prótese , Resultado do Tratamento
19.
Cochrane Database Syst Rev ; (7): CD003464, 2013 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-23839768

RESUMO

BACKGROUND: Patients with prosthetic heart valves are at increased risk for valve thrombosis and arterial thromboembolism. Oral anticoagulation alone, or the addition of antiplatelet drugs, has been used to minimise this risk. An important issue is the effectiveness and safety of the latter strategy. OBJECTIVES: This is an update of our previous review; the goal was to create a valid synthesis of all available, methodologically sound data to further assess the safety and efficacy of combined oral anticoagulant and antiplatelet therapy versus oral anticoagulant monotherapy in patients with prosthetic heart valves. SEARCH METHODS: We updated the previous searches from 2003 and 2010 on 16 January 2013 and searched the Cochrane Central Register of Controlled Trials (CENTRAL) on The Cochrane Library (2012, Issue 12), MEDLINE (OVID, 1946 to January Week 1 2013), and EMBASE (OVID, 1980 to 2013 Week 02). We have also looked at reference lists of individual reports, review articles, meta-analyses, and consensus statements. We included reports published in any language or in abstract form. SELECTION CRITERIA: All reports of randomised controlled trials comparing standard-dose oral anticoagulation to standard-dose oral anticoagulation and antiplatelet therapy in patients with one or more prosthetic heart valves. DATA COLLECTION AND ANALYSIS: Two review authors independently performed the search strategy, assessed trials for inclusion and study quality, and extracted data. We collected adverse effects information from the trials. MAIN RESULTS: One new study has been identified and included in this update. In total, 13 studies involving 4122 participants were included in this review update. Years of publication ranged from 1971 to 2011. Compared with anticoagulation alone, the addition of an antiplatelet agent reduced the risk of thromboembolic events (odds ratio (OR) 0.43, 95% confidence interval (CI) 0.32 to 0.59; P < 0.00001) and total mortality (OR 0.57, 95% CI 0.42 to 0.78; P = 0.0004). Aspirin and dipyridamole reduced these events similarly. The risk of major bleeding was increased when antiplatelet agents were added to oral anticoagulants (OR 1.58, 95% CI 1.14 to 2.18; P = 0.006).For major bleeding, there was no evidence of heterogeneity between aspirin and dipyridamole and in the comparison of trials performed before and after 1990, around the time when anticoagulation standardisation with the international normalised ratio was being implemented. A lower daily dose of aspirin (< 100 mg) may be associated with a lower major bleeding risk than higher doses. AUTHORS' CONCLUSIONS: Adding antiplatelet therapy, either dipyridamole or low-dose aspirin, to oral anticoagulation decreases the risk of systemic embolism or death among patients with prosthetic heart valves. The risk of major bleeding is increased with antiplatelet therapy. These results apply to patients with mechanical prosthetic valves or those with biological valves and indicators of high risk such as atrial fibrillation or prior thromboembolic events. The effectiveness and safety of low-dose aspirin (100 mg daily) appears to be similar to higher-dose aspirin and dipyridamole. In general, the quality of the included trials tended to be low, possibly reflecting the era when the majority of the trials were conducted (1970s and 1980s when trial methodology was less advanced).


Assuntos
Anticoagulantes/uso terapêutico , Próteses Valvulares Cardíacas/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Tromboembolia/prevenção & controle , Administração Oral , Anticoagulantes/efeitos adversos , Aspirina/efeitos adversos , Aspirina/uso terapêutico , Dipiridamol/efeitos adversos , Dipiridamol/uso terapêutico , Quimioterapia Combinada/métodos , Hemorragia/induzido quimicamente , Humanos , Inibidores da Agregação Plaquetária/efeitos adversos , Ensaios Clínicos Controlados Aleatórios como Assunto
20.
Curr Cardiol Rep ; 15(8): 384, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23812836

RESUMO

The accurate quantification of mitral regurgitation (MR) using 2D imaging tools is difficult due to its structural complexity; however, it is crucially important in clinical medicine as MR severity has prognostic consequences. Novel 3-dimensional (3D) echocardiography and 3-dimensional (3D) color Doppler methods can provide quantitative and qualitative classification of MR including measurement of the vena contracta area, regurgitant volume, regurgitant fraction, and effective regurgitant orifice area (EROA). Nevertheless, with so many conventional and developing techniques it can be difficult to decide which technique to use for selected patients. We suggest using an approach that is focused not only on the techniques and measurements but also combines imaging portability, availability, clinical efficiency, and accurate and reproducible assessments. In this review we discuss the established and emerging applications of 3D color Doppler for the quantification of MR severity.


Assuntos
Insuficiência da Valva Mitral/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo/fisiologia , Ecocardiografia Doppler em Cores/métodos , Ecocardiografia Tridimensional/métodos , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA