Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(20)2022 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-36298321

RESUMO

For a small satellite, the processor onboard the attitude determination and control system (ADCS) is required to monitor, communicate, and control all the sensors and actuators. In addition, the processor is required to consistently communicate with the satellite bus. Consequently, the processor is unable to ensure all the sensors and actuators will immediately respond to the data acquisition request, which leads to asynchronous data problems. The extended Kalman filter (EKF) is commonly used in the attitude determination process, but it assumes fully synchronous data. The asynchronous data problem would greatly degrade the attitude determination accuracy by EKF. To minimize the attitude estimation accuracy loss due to asynchronous data while ensuring a reasonable computational complexity for small satellite applications, this paper proposes the simplex-back-propagation Kalman filter (SBPKF). The proposed SBPKF incorporates the time delay, gyro instability, and navigation error into both the measurement and covariance estimation during the Kalman update process. The performance of SBPKF has been compared with EKF, modified adaptive EKF (MAEKF), and moving-covariance Kalman filter (MC-KF). Simulation results show that the attitude estimation error of SBPKF is at least 30% better than EKF and MC-KF. In addition, the SBPKF's computational complexity is 17% lower than MAEKF and 29% lower than MC-KF.

2.
Sensors (Basel) ; 15(4): 7434-53, 2015 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-25822140

RESUMO

Distributed transmission rate tuning is important for a wide variety of IEEE 802.15.4 network applications such as industrial network control systems. Such systems often require each node to sustain certain throughput demand in order to guarantee the system performance. It is thus essential to determine a proper transmission rate that can meet the application requirement and compensate for network imperfections (e.g., packet loss). Such a tuning in a heterogeneous network is difficult due to the lack of modeling techniques that can deal with the heterogeneity of the network as well as the network traffic changes. In this paper, a distributed transmission rate tuning algorithm in a heterogeneous IEEE 802.15.4 CSMA/CA network is proposed. Each node uses the results of clear channel assessment (CCA) to estimate the busy channel probability. Then a mathematical framework is developed to estimate the on-going heterogeneous traffics using the busy channel probability at runtime. Finally a distributed algorithm is derived to tune the transmission rate of each node to accurately meet the throughput requirement. The algorithm does not require modifications on IEEE 802.15.4 MAC layer and it has been experimentally implemented and extensively tested using TelosB nodes with the TinyOS protocol stack. The results reveal that the algorithm is accurate and can satisfy the throughput demand. Compared with existing techniques, the algorithm is fully distributed and thus does not require any central coordination. With this property, it is able to adapt to traffic changes and re-adjust the transmission rate to the desired level, which cannot be achieved using the traditional modeling techniques.

3.
Sensors (Basel) ; 15(5): 9610-27, 2015 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-25915589

RESUMO

This paper presents an unrestrained measurement system based on a wearable wireless ultrasonic sensor network to track the lower extremity joint and trunk kinematics during a squat exercise with only one ultrasonic sensor attached to the trunk. The system consists of an ultrasound transmitter (mobile) and multiple receivers (anchors) whose positions are known. The proposed system measures the horizontal and vertical displacement, together with known joint constraints, to estimate joint flexion/extension angles using an inverse kinematic model based on the damped least-squares technique. The performance of the proposed ultrasonic measurement system was validated against a camera-based tracking system on eight healthy subjects performing a planar squat exercise. Joint angles estimated from the ultrasonic system showed a root mean square error (RMSE) of 2.85° ± 0.57° with the reference system. Statistical analysis indicated great agreements between these two systems with a Pearson's correlation coefficient (PCC) value larger than 0.99 for all joint angles' estimation. These results show that the proposed ultrasonic measurement system is useful for applications, such as rehabilitation and sports.


Assuntos
Técnicas Biossensoriais/métodos , Extremidade Inferior/fisiologia , Ultrassom/métodos , Fenômenos Biomecânicos , Exercício Físico/fisiologia , Humanos , Articulações/fisiologia , Amplitude de Movimento Articular/fisiologia
4.
Sensors (Basel) ; 14(8): 15434-57, 2014 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-25140636

RESUMO

In this paper, a low-cost motion analysis system using a wireless ultrasonic sensor network is proposed and investigated. A methodology has been developed to extract spatial-temporal gait parameters including stride length, stride duration, stride velocity, stride cadence, and stride symmetry from 3D foot displacements estimated by the combination of spherical positioning technique and unscented Kalman filter. The performance of this system is validated against a camera-based system in the laboratory with 10 healthy volunteers. Numerical results show the feasibility of the proposed system with average error of 2.7% for all the estimated gait parameters. The influence of walking speed on the measurement accuracy of proposed system is also evaluated. Statistical analysis demonstrates its capability of being used as a gait assessment tool for some medical applications.


Assuntos
Marcha/fisiologia , Ultrassom , Fenômenos Biomecânicos , Humanos
5.
IEEE Trans Neural Syst Rehabil Eng ; 24(1): 88-97, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25769165

RESUMO

This paper presents a new highly accurate gait phase detection system using wearable wireless ultrasonic sensors, which can be used in gait analysis or rehabilitation applications. The gait phase detection system uses the foot displacement information during walking to extract the following gait phases: heel-strike, heel-off, toe-off, and mid-swing. The displacement of foot-mounted ultrasonic sensor is obtained from several passive anchors placed at known locations by employing local spherical positioning technique, which is further enhanced by the combination of recursive Newton-Gauss method and Kalman Filter. The algorithm performance is examined by comparing with a commercial optical motion tracking system with ten healthy subjects and two foot injured subjects. Accurate estimates of gait cycle (with an error of -0.02 ±0.01 s), stance phase(with an error of 0.04±0.03 s), and swing phase (with an error of -0.05±0.03 s) compared to the reference system are obtained. We have also investigated the influence of walking velocities on the performance of the proposed gait phase detection algorithm. Statistical analysis shows that there is no significant difference between both systems during different walking speeds. Moreover, we have tested and discussed the possibility of the proposed system for clinical applications by analyzing the experimental results for both healthy and injured subjects. The experiments show that the estimated gait phases have the potential to become indicators for sports and rehabilitation engineering.


Assuntos
Actigrafia/instrumentação , Pé/fisiologia , Marcha/fisiologia , Monitorização Ambulatorial/instrumentação , Ultrassonografia/instrumentação , Tecnologia sem Fio/instrumentação , Adulto , Algoritmos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transdutores , Caminhada/fisiologia
6.
IEEE J Biomed Health Inform ; 19(2): 446-52, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24759996

RESUMO

Techniques that could be used to monitor human motion precisely are helpful in various applications such as rehabilitation, gait analysis, and athletic performance analysis. This paper focuses on the 3-D foot trajectory measurements based on a wearable wireless ultrasonic sensor network. The system consists of an ultrasonic transmitter (mobile) and several receivers (anchors) with fixed known positions. In order not to restrict the movement of subjects, a radio frequency (RF) module is used for wireless data transmission. The RF module also provides the synchronization clock between mobile and anchors. The proposed system measures the time-of-arrival (TOA) of the ultrasonic signal from mobile to anchors. Together with the knowledge of the anchor's position, the absolute distance that the signal travels can be computed. Then, the range information defines a circle centered at this anchor with radius equal to the measured distance, and the mobile resides within the intersections of several such circles. Based on the TOA-based tracking technique, the 3-D foot trajectories are validated against a camera-based motion capture system for ten healthy subjects walking on a treadmill at slow, normal, and fast speeds. The experimental results have shown that the ultrasonic system has sufficient accuracy of net root-mean-square error ( 4.2 cm) for 3-D displacement, especially for foot clearance with accuracy and standard deviation ( 0.62 ±7.48 mm) compared to the camera-based motion capture system. The small form factor and lightweight feature of the proposed system make it easy to use. Such a system is also much lower in cost compared to the camera-based tracking system.


Assuntos
Pé/fisiologia , Monitorização Ambulatorial/instrumentação , Processamento de Sinais Assistido por Computador , Caminhada/fisiologia , Tecnologia sem Fio/instrumentação , Adulto , Algoritmos , Fenômenos Biomecânicos/fisiologia , Desenho de Equipamento , Feminino , Humanos , Masculino , Monitorização Ambulatorial/métodos , Reprodutibilidade dos Testes , Adulto Jovem
7.
IEEE J Biomed Health Inform ; 19(2): 549-58, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24686306

RESUMO

Energy is scarce in mobile computing devices including wearable and implantable devices in a wireless body area network. In this paper, an adaptive routing protocol is developed and analyzed which minimizes the energy cost per bit of information by using the channel information to choose the best strategy to route data. In this approach, the source node will switch between direct and relayed communication based on the quality of the link and will use the relay only if the channel quality is below a certain threshold. The mathematical model is then validated through simulations which shows that the adaptive routing strategy can improve energy efficiency significantly compared with existing methods.


Assuntos
Redes de Comunicação de Computadores , Tecnologia de Sensoriamento Remoto/métodos , Processamento de Sinais Assistido por Computador , Tecnologia sem Fio , Humanos , Cadeias de Markov
8.
Artigo em Inglês | MEDLINE | ID: mdl-25571354

RESUMO

This paper introduces a novel method for arm flexion/extension angles measurement using wireless ultrasonic sensor network. The approach uses unscented Kalman filter and D-H kinematical chain model to retrieve the joint angles. This method was experimentally validated by calculating the 2-dimensional wrist displacements from one mobile, placed on the point of subject's wrist, and four anchors. The performance of the proposed ultrasonic motion analysis system was bench-marked by commercial camera motion capture system. The experimental results demonstrate that a favorable performance of the proposed system in the estimation of upper limb motion. The proposed system is wireless, easy to wear, to use and much cheaper than current camera system. Thus, it has the potential to become a new and useful tool for routine clinical assessment of human motion.


Assuntos
Braço/fisiologia , Movimento/fisiologia , Tecnologia sem Fio , Algoritmos , Fenômenos Biomecânicos , Humanos , Ultrassom , Tecnologia sem Fio/instrumentação , Punho
9.
Artigo em Inglês | MEDLINE | ID: mdl-25571433

RESUMO

In this paper, an ultrasonic-based system for foot parameters measurement has been proposed and investigated. An extended Kalman filtering-based methodology has been developed to extract foot parameters including step length, stride length and cycle time from horizontal displacement during walking. The system comprises of one ultrasonic transmitter (mobile) and four ultrasonic receivers (anchors) with fixed known positions. A Radio Frequency (RF) module is used in our system not only to provide synchronization clock between the mobile and anchors, but also to transmit collected data wirelessly to reduce the wires used. To evaluate the performance of the proposed system, the 2-dimensional foot displacement and the foot parameters were measured and validated against the reference camera motion capture system. These experiment results demonstrate the capability of the proposed system being used as a gait analysis tool for rehabilitation and other medical applications.


Assuntos
Marcha , Fenômenos Biomecânicos , , Humanos , Som , Caminhada , Tecnologia sem Fio
10.
IEEE J Biomed Health Inform ; 18(1): 300-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24403428

RESUMO

In this paper, a new method for measuring and monitoring human body joint angles, which uses wearable ultrawideband (UWB) transceivers mounted on body segments, is proposed and investigated. The model is based on providing a high ranging accuracy (intersensor distance) between a pair of transceivers placed on the adjacent segments of the joint center of rotation. The measured distance is then used to compute the joint angles based on the law of cosines. The performance of the method was compared with a flexible goniometer by simultaneously measuring joint flexion-extension angles at different angular velocities, ranging between 8 and 90(°) /s. The measurement errors were evaluated by the average differences between two sets of data (ranging from 0.8(°) for slow movement to 2.8(°) for fast movement), by standard deviation (ranging from 1.2(°) to 4.2(°) for various movement speeds) and by the Pearson correlation coefficient (greater than 0.99) which demonstrates the very good performance of the UWB-based approach. The experimental results have shown that the system has sufficient accuracy for clinical applications, such as rehabilitation.


Assuntos
Engenharia Biomédica/instrumentação , Articulações/fisiologia , Amplitude de Movimento Articular/fisiologia , Reabilitação/instrumentação , Telemetria/instrumentação , Fenômenos Biomecânicos/fisiologia , Humanos , Processamento de Sinais Assistido por Computador
11.
Artigo em Inglês | MEDLINE | ID: mdl-24110907

RESUMO

Foot clearance above ground is a key factor for a better understanding of the complicated relationship between falls and gait. This paper proposes a wearable system using UWB transceivers to monitor the vertical heel/toe clearance during walking. First, a pair of very small and light antennas is placed on a point approximating to the heel/toe of the foot, acting as a transmitter and receiver. Then, the reflected signal from ground is captured and propagation delay is detected using noise suppressed Modified-Phase-Only-Correlator (MPOC). The performance of the UWB-based system was compared with an ultrasound system for stationary movements. The experimental results show that an overall mean difference between these two systems is about 0.634mm with correlation coefficient value of 0.9604. The UWB-based system is then used to measure foot clearance during walking which shows promising results for gait events detection.


Assuntos
Pé/fisiologia , Monitorização Fisiológica/instrumentação , Rádio , Caminhada/fisiologia , Acidentes por Quedas , Fenômenos Biomecânicos , Humanos , Cinética , Ultrassom
12.
Artigo em Inglês | MEDLINE | ID: mdl-24111409

RESUMO

This paper proposes a wearable system using UWB transceivers to measure the knee flexion/extension angle parameter, who is known to be of clinical importance. First, a pair of very small and light antennas is placed on the adjacent segments of knee joint. Then, the range data between these two antennas is acquired using Time of Arrival (TOA) estimator. We further use the measured distance to compute the flexion/extension angle using the law of cosines. The performance of the method was compared with a flexible goniometer by simultaneously measuring knee flexion-extension angle. The experimental results show that the system has reasonable performance and has sufficient accuracy for clinical applications.


Assuntos
Articulação do Joelho/fisiologia , Joelho/fisiologia , Movimento , Amplitude de Movimento Articular , Algoritmos , Fenômenos Biomecânicos , Desenho de Equipamento , Humanos , Movimento (Física) , Rádio , Ondas de Rádio , Reprodutibilidade dos Testes , Tecnologia sem Fio
13.
IEEE Trans Biomed Eng ; 55(8): 2011-21, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18632364

RESUMO

This paper studies the possibility of distinguishing between benign and malignant masses by exploiting the morphology-dependent temporal and spectral characteristics of their microwave backscatter response in ultra-wideband breast cancer detection. The spiculated border profiles of 2-D breast masses are generated by modifying the baseline elliptical rings based upon the irregularity of their peripheries. Furthermore, the single- and multilayer lesion models are used to characterize a distinct mass region followed by a sharp transition to background, and a blurred mass border exhibiting a gradual transition to background, respectively. Subsequently, the complex natural resonances (CNRs) of the backscatter microwave signature can be derived from the late-time target response and reveal diagnostically useful information. The fractional sequence CLEAN algorithm is proposed to estimate the lesions' delay intervals and identify the late-time responses. Finally, it is shown through numerical examples that the locations of dominant CNRs are dependent on the lesion morphologies, where 2-D computational breast phantoms with single and multiple lesions are investigated. The analysis is of potential use for discrimination between benign and malignant lesions, where the former usually possesses a better-defined, more compact shape as opposed to the latter.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/fisiopatologia , Diagnóstico por Computador/métodos , Micro-Ondas , Modelos Biológicos , Simulação por Computador , Campos Eletromagnéticos , Feminino , Humanos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
14.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 2630-3, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17945730

RESUMO

This paper presents a generic framework for the modeling of ultra-wideband (UWB) signal propagation in human breast, which facilitates system-level simulations and provides performance prediction. The clutter associated with the breast tissue heterogeneity is modeled through several key parameters depending on the tissue compositions. Subsequently, important channel properties such as the backscatter energy and the probability density function of time-of-arrival are derived. The modified Hermite polynomials, which fit well into the real pulse shapes, are then used to model the UWB signals. Armed with the channel/signal model preliminaries, three metrics are proposed, namely, the mean clutter response, the clean tumor response, and the worst-case clutter response. The generalized model provides a parsimonious way to study the effects of tissue structures, pulse templates, and array setup on the performance of a specified UWB imaging system. Numerical examples are used to demonstrate the usefulness of the proposed approach.


Assuntos
Neoplasias da Mama/diagnóstico , Neoplasias da Mama/fisiopatologia , Mama/fisiopatologia , Diagnóstico por Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Micro-Ondas , Modelos Biológicos , Algoritmos , Simulação por Computador , Feminino , Humanos , Doses de Radiação , Radiometria/métodos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
15.
Artigo em Inglês | MEDLINE | ID: mdl-17945609

RESUMO

It has been shown that remote monitoring of pulmonary activity can be achieved using ultra-wideband (UWB) systems, which shows promise in home healthcare, rescue, and security applications. In this paper, a geometry-based statistical channel model is developed for simulating the reception of UWB signals in the indoor propagation environment. This model enables replication of time-varying multipath profiles due to the displacement of a human chest. Subsequently, a UWB distributed cognitive radar system (UWB-DCRS) is developed for the robust detection of chest cavity motion and the accurate estimation of respiration rate. The analytical framework can serve as a basis in the planning and evaluation of future measurement programs.


Assuntos
Diagnóstico por Computador/métodos , Modelos Biológicos , Monitorização Ambulatorial/métodos , Radar , Testes de Função Respiratória/métodos , Mecânica Respiratória/fisiologia , Simulação por Computador , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA