Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Cancer ; 20(1): 1112, 2020 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-33198676

RESUMO

BACKGROUND: This study aimed to quantify the dosimetric differences between the planned and delivered dose to tumor and normal organs in locally advanced non-small cell lung cancer (LANSCLC) treated with hypofractionated radiotherapy (HRT), and to explore the necessity and identify optimal candidates for adaptive radiotherapy (ART). METHODS: Twenty-seven patients with stage III NSCLC were enrolled. Planned radiation dose was 51Gy in 17 fractions with cone-beam CT (CBCT) acquired at each fraction. Virtual CT was generated by deformable image registration (DIR) of the planning CT to CBCT for dose calculation and accumulation. Dosimetric parameters were compared between original and accumulated plans using Wilcoxon signed rank test. Correlations between dosimetric differences and clinical variables were analyzed using Mann-Whitney U test or Chi-square test. RESULTS: Patients had varied gross tumor volume (GTV) reduction by HRT (median reduction rate 11.1%, range - 2.9-44.0%). The V51 of planning target volume for GTV (PTV-GTV) was similar between original and accumulated plans (mean, 88.2% vs. 87.6%, p = 0.452). Only 11.1% of patients had above 5% relative decrease in V51 of PTV-GTV in accumulated plans. Compared to the original plan, limited increase (median relative increase < 5%) was observed in doses of total lung (mean dose, V20 and V30), esophagus (mean dose, maximum dose) and heart (mean dose, V30 and V40) in accumulated plans. Less than 30% of patients had above 5% relative increase of lung or heart doses. Patients with quick tumor regression or baseline obstructive pneumonitis showed more notable increase in doses to normal structures. Patients with baseline obstructive atelectasis showed notable decrease (10.3%) in dose coverage of PTV-GTV. CONCLUSIONS: LANSCLC patients treated with HRT had sufficient tumor dose coverage and acceptable normal tissue dose deviation. ART should be applied in patients with quick tumor regression and baseline obstructive pneumonitis/atelectasis to spare more normal structures.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/radioterapia , Órgãos em Risco/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Adulto , Idoso , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/patologia , Feminino , Seguimentos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Prognóstico , Dosagem Radioterapêutica , Carga Tumoral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA