Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Forensic Sci Int ; 314: 110389, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32629358

RESUMO

Gunshot residue (GSR) is a valuable form of forensic trace evidence in the investigation of firearms crime. The current gold-standard approach does not include the analysis of organic components of the residues, which may be a deficiency, particularly in cases where there is little to no inorganic gunshot residue (IGSR) present or its attribution to a firearm source is ambiguous. A solvent extraction method was used for the extraction of organic GSR (OGSR) from the most common sampling device used to collect IGSR (i.e., SEM stubs with double-sided carbon adhesive tape). It was found that extraction did not significantly disturb inorganic GSR present on stubs, which raises the possibility that a valuable, comprehensive tandem analysis of both organic and inorganic GSR may be implemented using a single and commonly used residue collection device. The organic extract was analysed using Ultra High Performance Liquid Chromatography coupled to an Ion Trap Mass Spectrometer using Electrospray Ionisation (UHPLC-ESI-MS/MS), with preliminary results indicating that organic components can be extracted and detected at levels appropriate to casework GSR analysis. Testing of traces collected from the hands of recent shooters showed detection of stabiliser compounds typical of OGSR, which were confirmed to be present in the test ammunition's propellant. Total analysis time is approximately 30min per specimen, including preparation, instrumental analysis and data review. As the first step in the examination of GSR stubs in relation to a shooting case, extraction of organics and analysing them for the presence of OGSR may bring two operational benefits. First, that approach may be a useful way to determine which stubs warrant priority examination for IGSR, and second, it offers the possibility of providing relatively rapid case information to investigators.

2.
Forensic Sci Int ; 297: 293-301, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30852412

RESUMO

In order to have confidence in the integrity of a GSR test result, it is essential to understand the factors that may influence the presence of GSR particles on a person of interest's hands beyond the discharge of a firearm. One important consideration is the possibility that a person of interest (POI) may become contaminated with GSR through their interactions with firearms-carrying police officers during the process of apprehension or arrest. This situation has the potential to result in a false positive error, and potentially result in the mistaken inclusion of a POI in an investigation. Prior studies have indicated that receiving a firearm at the start of shift represents a significant contamination event, which may result in GSR persisting on the hands of police officers (Cook, 2016). Firearms-carrying police officers were sampled at various points throughout their shift to ascertain the extent of persistence of GSR on their hands, as a potential population that could then be transferred. A secondary transfer study was also conducted, with several 'mock arrest' scenarios used as a means of modelling the extent and dynamics of any secondary GSR transfer. When compared to the random population, it was found that police exhibit GSR contamination of their hands at a higher frequency. 7.9% of the officers sampled in this study returned at least one, 3-component particle characteristic of GSR. Further, 75% of the officers tested had at least one particle considered consistent with GSR present on their hands. However, the overall particle numbers were relatively low, with the average reported number of characteristic particles being less than five, and the greatest number reported being twelve. When considering the possibility of secondary transfer occurring during the process of arrest, it was further determined through secondary transfer experiments that the most probable transfer situation was fewer than 25% of the particles present on an officer's hands would be transferred to a POI as a result of a short 'mock arrest' contact. We conclude that although the possibility of GSR contamination through the process of arrest exists, and is worthy of consideration in the assessment of GSR evidence, it is not an overwhelming, or major concern.


Assuntos
Antimônio/análise , Bário/análise , Chumbo/análise , Polícia , Pele/química , Tato , Armas de Fogo , Mãos , Humanos , Microscopia Eletrônica de Varredura
3.
Forensic Sci Int ; 297: 100-110, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30784947

RESUMO

Recent work in the forensic analysis of Gunshot residues (GSR) has suggested that the sub-surface or internal composition and morphology of these residues be explored. A particular area of interest is in heavy metal free, or non-toxic ammunition, which are becoming more frequently encountered in the marketplace. As the formulation of the primer compound changes the conditions of the firearm discharge, there is the possibility that different primer formulations may result in the formation of different GSR particles with distinct internal morphologies and compositions. To that end, the internal morphology and composition of GSR particles may provide additional information that could be useful in the investigation of firearms crime. This research investigated the internal morphology of GSR originating from a variety of different ammunition products. Both traditional three-component primed ammunition, and a selection of heavy metal free and non-toxic alternatives were considered. Particles were identified using SEM-EDS, before being cross-sectioned using a focussed ion beam (FIB) instrument. The FIB-sectioned particles were then re-acquired and mapped using SEM-EDS, to assess both internal morphology and composition. Particles observed in this study presented distinct morphological and compositional features at the sub-particle level that may provide an indication of the primer formulation from which they originated. That said, further investigation of a variety of samples should be undertaken to verify the consistency of these features, or any deviations that may be observed based on primer type. However, these results indicate that there may be promise in obtaining additional detail from sub-particle morphology and composition.

4.
Forensic Sci Int ; 298: 359-371, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30928776

RESUMO

When lead, barium and antimony, or lead, barium, calcium, silicon and tin are found together in particles associated with a shooting investigation they are considered characteristic of gunshot residue (GSR). Antimony and tin are often absent from the primer of many low calibre rimfire ammunitions, which are the type most commonly used in Australia. Therefore, the likelihood of characteristic particles forming during the firing process of such rimfire ammunition is significantly less than the likelihood of these particles arising from higher calibre ammunition. The majority of rimfire ammunition examined in this research contains ground glass in the primer, which functions as a frictionator. These ammunitions produce a small number of gunshot residue particles containing glass coated with other primer components, which we refer to as glass-containing GSR (gGSR). If these particles are observed in an investigation, they have the potential to add a new dimension to gunshot residue analysis because they are not common in the environment. Furthermore, the composition of glass frictionator is stable during firing, which raises the possibility that chemical testing of the glass in gGSR may be used to identify the ammunition from which the residue was derived or to link deposits of GSR. This paper examines the application of scanning electron microscopy-energy dispersive X-ray spectrometry (SEM-EDS), focussed ion beam (FIB) techniques and time of flight-secondary ion mass spectrometry (ToF-SIMS) to the semi-quantitative analysis and comparisons of gGSR and frictionator extracted from unfired cartridges. SEM-EDS is effective for comparing gGSR with unfired frictionator, but the use of FIB to expose clean glass from the centre of gGSR followed by ToF-SIMS, or ToF-SIMS using ion sputtering to expose clean glass, offers more power for comparisons due to their capability for higher discrimination between frictionators from different sources.

5.
Forensic Sci Int ; 298: 284-297, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30925347

RESUMO

In an ideal case, the value of traces would be determined numerically and presented through the use of likelihood ratios or verbal-equivalent scales. A problem in the evaluation of gunshot residue (GSR) evidence using these models is that in many shooting scenarios insufficient data exist to support a quantitative model of interpretation. The complex relationship that exists between ammunition composition and post-firing residues makes quantitative interpretation more difficult for GSR than for other traces such as glass. When evaluating the significance of traces in a quantitative model, the value of a trace is reduced as the number of random sources that could produce the trace increases. Previously published works have suggested that glass-containing GSR (gGSR), which is glass encrusted with lead (Pb) and barium (Ba) residues, are a new type of GSR not already classified under ASTM E1588 - 17. If random sources of particles resembling gGSR are rare, then gGSR may be valuable evidentiary traces. In order to potentially incorporate these particles into a future model, the general background prevalence of gGSR and specific sources capable of producing similar particles must be understood. Therefore, particles from fireworks, matches, and cartridge actuated nail guns were assessed on an individual basis and at a population level. These sources, known to produce particles resembling GSR, were assessed using backscattered electron - scanning electron microscopy - energy dispersive X-ray spectroscopy analysis (BSE-SEM-EDS) for the presence of glass-containing particles that resemble gGSR. In the experiments described in this article the nail gun produced particles compositionally indistinguishable from gGSR, due to the primer in the brand of nail gun cartridges used containing glass as the frictionator in addition to Pb and Ba compounds. In this study, no particles were located from fireworks or matches that were indistinguishable from gGSR, nor was any evidence observed or found in the literature that would suggest that such particles could be formed.

6.
Forensic Sci Int ; 270: 76-82, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27915190

RESUMO

Previous research has raised the possibility that automotive brake pads can produce particles that are both compositionally and morphologically similar to gunshot residue (GSR). These studies, published in the early 2000s, coincided with the reduction or removal of unnecessary sources of lead from the automotive industry. The question therefore arises whether modern brake pads might still be a relevant source of 'GSR-like' particles. In the present study, a total of 75 brake pads taken from a range of cars currently on the road in Adelaide, South Australia, were collected from service centres. These pads were screened by XRF, and 12 were selected as representatives of the types of pads available on the market. Some pads generated XRF results for elements particularly relevant to GSR analysis. Signals for barium and antimony were commonly observed, with some pads showing results possibly attributable to lead. The surfaces of these 12 pads were directly sampled using aluminium stubs equipped with carbon-filled adhesive tape. Following this, they were screened using SEM-EDS and an automated GSR particle search in order to detect particles containing lead, barium or antimony. No particles containing all of these elements were found, although a large number of particles containing both barium and antimony were located. Other particulate samples were collected using stubs from persons or objects associated with brakes in order to examine whether particles similar to GSR might be present on them. No three-component particles were detected in samples collected from the wheel rims or the hands of those exposed to automobiles. From this study of common, contemporary cars, brake pads and brake pad technicians, it was determined that the possibility of obtaining three-component 'GSR-like' particles from brake pads appears to be much lower now than when this issue was first raised in the early 2000s. While some brake pads do produce particles containing barium and antimony, they are often angular particles that contain sulphur. Furthermore, these 'GSR-like' particles are commonly found together with an abundance of particles containing iron. The particle evidence evaluated in total allows clear differentiation between residues originating from brakes and residues originating from firearms.

7.
Forensic Sci Int ; 266: 289-298, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27348466

RESUMO

Gunshot residue (GSR) is a valuable form of forensic trace evidence in the investigation of firearms-related suicide and crime. In order to ensure that such evidence is given appropriate evidential weighting when it comes to case investigations, the dynamics of the deposition and distribution of GSR must be understood. As the activity of the subject after firing is a major factor in the retention of GSR, cases of suicide involving a firearm provide an opportunity to assess GSR distribution where post-shooting activity is not an issue, assuming the subject had not been moved. Seventy-one cases of suicide by gunshot in South Australia between 1998 and 2014 were examined to collect data on firearm type, calibre, and gunshot residue test results. Overall, 47% of cases were found to produce GSR results that were not of high probative value, even though it was known that the shooter had fired a firearm. Of particular interest were cases involving 0.22 rimfire ammunition, for which characteristic particles are not expected due to lack of antimony present in the primer. Despite this, 64% of these cases resulted in the detection of antimony-containing, three-component particles.


Assuntos
Ciências Forenses/métodos , Suicídio , Armas de Fogo/estatística & dados numéricos , Ciências Forenses/normas , Humanos , Austrália do Sul , Ferimentos por Arma de Fogo
8.
Forensic Sci Int ; 262: 150-5, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26990563

RESUMO

When considering the impact and value of gunshot residues (GSR) as forensic trace evidence, the likelihood of a suspect producing a positive GSR analysis result without having direct exposure to a firearm is a major consideration. Therefore, the random prevalence of GSR and 'GSR-like' residues in the wider population is a highly pertinent question when considering the probative value of such evidence. The random prevalence of GSR in two Australian jurisdictions - Victoria and South Australia - was assessed through the collection and analysis of GSR samples obtained from randomly selected members of the public. Volunteers were asked to declare any firearms use, hobbies or potential firearms exposure before allowing their hands to be sampled using aluminium GSR sample stubs coated in adhesive tape. A total of 289 samples, 120 from Victoria and 169 from South Australia were collected and analysed using scanning electron microscopy coupled with energy dispersive X-ray microanalysis (SEM-EDS). Across all samples, three 'characteristic' three-component Pb/Ba/Sb particles were detected from a single subject in South Australia, corresponding to an overall prevalence of 0.3%. Two-component 'consistent' particles were more prevalent, with Pb/Sb particles being the most frequently occurring, in 8% of samples, and in South Australia only. A number of samples, approximately 7%, showed populations of single element particles of Pb, Ba and Sb, which has the potential to generate a false positive for GSR if using a bulk analysis technique such as NAA or AAS. The prevalence of GSR or 'GSR like' particles in this study matches closely with similar surveys conducted in other jurisdictions. Such surveys are a useful foundation for the creation of a probabilistic method for the assessment of GSR evidence.


Assuntos
Antimônio/análise , Bário/análise , Mãos , Chumbo/análise , Pele/química , Adolescente , Adulto , Austrália , Reações Falso-Positivas , Feminino , Armas de Fogo , Balística Forense , Humanos , Masculino , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Estudos de Amostragem , Espectrometria por Raios X , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA