Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Circulation ; 142(14): 1361-1373, 2020 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-33017215

RESUMO

BACKGROUND: Many graft configurations are clinically used for valve-sparing aortic root replacement, some specifically focused on recapitulating neosinus geometry. However, the specific impact of such neosinuses on valvular and root biomechanics and the potential influence on long-term durability are unknown. METHODS: Using a custom 3-dimenstional-printed heart simulator with porcine aortic roots (n=5), the anticommissural plication, Stanford modification, straight graft (SG), Uni-Graft, and Valsalva graft configurations were tested in series using an incomplete counterbalanced measures design, with the native root as a control, to mitigate ordering effects. Hemodynamic and videometric data were analyzed using linear models with conduit as the fixed effect of interest and valve as a fixed nuisance effect with post hoc pairwise testing using Tukey's correction. RESULTS: Hemodynamics were clinically similar between grafts and control aortic roots. Regurgitant fraction varied between grafts, with SG and Uni-Graft groups having the lowest regurgitant fractions and anticommissural plication having the highest. Root distensibility was significantly lower in SG versus both control roots and all other grafts aside from the Stanford modification (P≤0.01 for each). All grafts except SG had significantly higher cusp opening velocities versus native roots (P<0.01 for each). Relative cusp opening forces were similar between SG, Uni-Graft, and control groups, whereas anticommissural plication, Stanford modification, and Valsalva grafts had significantly higher opening forces versus controls (P<0.01). Cusp closing velocities were similar between native roots and the SG group, and were significantly lower than observed in the other conduits (P≤0.01 for each). Only SG and Uni-Graft groups experienced relative cusp closing forces approaching that of the native root, whereas relative forces were >5-fold higher in the anticommissural plication, Stanford modification, and Valsalva graft groups. CONCLUSIONS: In this ex vivo modeling system, clinically used valve-sparing aortic root replacement conduit configurations have comparable hemodynamics but differ in biomechanical performance, with the straight graft most closely recapitulating native aortic root biomechanics.


Assuntos
Aorta/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese Vascular , Prótese Vascular , Modelos Cardiovasculares , Impressão Tridimensional , Animais , Humanos , Suínos
2.
Cytokine ; 127: 154974, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31978642

RESUMO

Although ischemic heart disease is the leading cause of death worldwide, mainstay treatments ultimately fail because they do not adequately address disease pathophysiology. Restoring the microvascular perfusion deficit remains a significant unmet need and may be addressed via delivery of pro-angiogenic cytokines. The therapeutic effect of cytokines can be enhanced by encapsulation within hydrogels, but current hydrogels do not offer sufficient clinical translatability due to unfavorable viscoelastic mechanical behavior which directly impacts the ability for minimally-invasive catheter delivery. In this report, we examine the therapeutic implications of dual-stage cytokine release from a novel, highly shear-thinning biocompatible catheter-deliverable hydrogel. We chose to encapsulate two protein-engineered cytokines, namely dimeric fragment of hepatocyte growth factor (HGFdf) and engineered stromal cell-derived factor 1α (ESA), which target distinct disease pathways. The controlled release of HGFdf and ESA from separate phases of the hyaluronic acid-based hydrogel allows extended and pronounced beneficial effects due to the precise timing of release. We evaluated the therapeutic efficacy of this treatment strategy in a small animal model of myocardial ischemia and observed a significant benefit in biological and functional parameters. Given the encouraging results from the small animal experiment, we translated this treatment to a large animal preclinical model and observed a reduction in scar size, indicating this strategy could serve as a potential adjunct therapy for the millions of people suffering from ischemic heart disease.


Assuntos
Hidrogéis/administração & dosagem , Infarto do Miocárdio/tratamento farmacológico , Infarto do Miocárdio/metabolismo , Miocárdio/metabolismo , Função Ventricular Esquerda/efeitos dos fármacos , Remodelação Ventricular/efeitos dos fármacos , Animais , Catéteres , Células Cultivadas , Modelos Animais de Doenças , Fator de Crescimento de Hepatócito/metabolismo , Humanos , Ácido Hialurônico/administração & dosagem , Isquemia Miocárdica/tratamento farmacológico , Isquemia Miocárdica/metabolismo , Miocárdio/patologia , Ratos
3.
J Vasc Access ; : 11297298231153716, 2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36765464

RESUMO

INTRODUCTION: Central venous catheters (CVCs) are often trimmed during heart transplantation and pediatric cardiac surgery. However, the risk of endothelial injury caused by the cut tip of the CVC has not been evaluated. We hypothesized that there is no difference in the degree of endothelial injury associated with trimmed CVCs versus standard untrimmed CVCs. METHODS: In four adult male sheep, the left external jugular vein was exposed in three segments, one designated for an untouched control group, one for the trimmed CVC group, and one for the untrimmed CVC group. Trimmed and untrimmed CVC tips were rotated circumferentially within their respective segments to abrade the lumen of the vein. The vein samples were explanted, and two representative sections from each sample were analyzed using hematoxylin and eosin (H&E) staining, as well as with immunohistochemistry against CD31, von Willebrand factor (vWF), endothelial nitric oxide synthase (eNOS), and caveolin. Higher immunohistochemical stain distributions and intensities are associated with normal health and function of the venous endothelium. Data are presented as counts with percentages or as means with standard error. RESULTS: H&E staining revealed no evidence of endothelial injury in 6/8 (75%) samples from the untouched control group, and no injury in 4/8 (50%) samples from both the trimmed and untrimmed CVC groups (p = 0.504). In all remaining samples from each group, only mild endothelial injury was observed. Immunohistochemical analysis comparing trimmed CVCs versus untrimmed CVCs revealed no difference in the percentage of endothelial cells staining positive for CD31 (57.5% ± 7.2% vs 55.0% ± 9.2%, p = 0.982), vWF (73.8% ± 8.0% vs 62.5% ± 9.6%, p = 0.579), eNOS (66.3% ± 4.2% vs 63.8% ± 7.5%, p = 0.962), and caveolin (53.8% ± 5.0% vs 51.3% ± 4.4%, p = 0.922). There were no significant differences between the groups in the distributions of stain intensity for CD31, vWF, eNOS, and caveolin. CONCLUSION: Trimmed CVCs do not increase endothelial injury compared to standard untrimmed CVCs.

4.
J Thorac Cardiovasc Surg ; 163(2): e161-e171, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-32747120

RESUMO

OBJECTIVE: The objective was to design and evaluate a clinically relevant, novel ex vivo bicuspid aortic valve model that mimics the most common human phenotype with associated aortic regurgitation. METHODS: Three bovine aortic valves were mounted asymmetrically in a previously validated 3-dimensional-printed left heart simulator. The non-right commissure and the non-left commissure were both shifted slightly toward the left-right commissure, and the left and right coronary cusps were sewn together. The left-right commissure was then detached and reimplanted 10 mm lower than its native height. Free margin shortening was used for valve repair. Hemodynamic status, high-speed videography, and echocardiography data were collected before and after the repair. RESULTS: The bicuspid aortic valve model was successfully produced and repaired. High-speed videography confirmed prolapse of the fused cusp of the baseline bicuspid aortic valve models in diastole. Hemodynamic and pressure data confirmed accurate simulation of diseased conditions with aortic regurgitation and the subsequent repair. Regurgitant fraction postrepair was significantly reduced compared with that at baseline (14.5 ± 4.4% vs 28.6% ± 3.4%; P = .037). There was no change in peak velocity, peak gradient, or mean gradient across the valve pre- versus postrepair: 293.3 ± 18.3 cm/sec versus 325.3 ± 58.2 cm/sec (P = .29), 34.3 ± 4.2 mm Hg versus 43.3 ± 15.4 mm Hg (P = .30), and 11 ± 1 mm Hg versus 9.3 ± 2.5 mm Hg (P = .34), respectively. CONCLUSIONS: An ex vivo bicuspid aortic valve model was designed that recapitulated the most common human phenotype with aortic regurgitation. These valves were successfully repaired, validating its potential for evaluating valve hemodynamics and optimizing surgical repair for bicuspid aortic valves.


Assuntos
Insuficiência da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Procedimentos Cirúrgicos Cardiovasculares , Modelos Anatômicos , Animais , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/patologia , Insuficiência da Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide/patologia , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Doença da Válvula Aórtica Bicúspide/cirurgia , Procedimentos Cirúrgicos Cardiovasculares/educação , Procedimentos Cirúrgicos Cardiovasculares/métodos , Bovinos , Ecocardiografia , Hemodinâmica , Humanos
5.
J Thorac Cardiovasc Surg ; 164(6): e389-e405, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-34649718

RESUMO

OBJECTIVES: Neonatal rodents and piglets naturally regenerate the injured heart after myocardial infarction. We hypothesized that neonatal rabbits also exhibit natural heart regeneration after myocardial infarction. METHODS: New Zealand white rabbit kits underwent sham surgery or left coronary ligation on postnatal day 1 (n = 94), postnatal day 4 (n = 11), or postnatal day 7 (n = 52). Hearts were explanted 1 day postsurgery to confirm ischemic injury, at 1 week postsurgery to assess cardiomyocyte proliferation, and at 3 weeks postsurgery to assess left ventricular ejection fraction and scar size. Data are presented as mean ± standard deviation. RESULTS: Size of ischemic injury as a percentage of left ventricular area was similar after myocardial infarction on postnatal day 1 versus on postnatal day 7 (42.3% ± 5.4% vs 42.3% ± 4.7%, P = .9984). Echocardiography confirmed severely reduced ejection fraction at 1 day after postnatal day 1 myocardial infarction (33.7% ± 5.3% vs 65.2% ± 5.5% for postnatal day 1 sham, P = .0001), but no difference at 3 weeks after postnatal day 1 myocardial infarction (56.0% ± 4.0% vs 58.0% ± 3.3% for postnatal day 1 sham, P = .2198). Ejection fraction failed to recover after postnatal day 4 myocardial infarction (49.2% ± 1.8% vs 58.5% ± 5.8% for postnatal day 4 sham, P = .0109) and postnatal day 7 myocardial infarction (39.0% ± 7.8% vs 60.2% ± 5.0% for postnatal day 7 sham, P &lt; .0001). At 3 weeks after infarction, fibrotic scar represented 5.3% ± 1.9%, 14.3% ± 4.9%, and 25.4% ± 13.3% of the left ventricle area in the postnatal day 1, postnatal day 4, and postnatal day 7 groups, respectively. An increased proportion of peri-infarct cardiomyocytes expressed Ki67 (15.9% ± 1.8% vs 10.2% ± 0.8%, P = .0039) and aurora B kinase (4.0% ± 0.9% vs 1.5% ± 0.6%, P = .0088) after postnatal day 1 myocardial infarction compared with sham, but no increase was observed after postnatal day 7 myocardial infarction. CONCLUSIONS: A neonatal leporine myocardial infarction model reveals that newborn rabbits are capable of age-dependent natural heart regeneration.


Assuntos
Infarto do Miocárdio , Função Ventricular Esquerda , Animais , Coelhos , Cicatriz , Coração/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Miócitos Cardíacos , Regeneração , Volume Sistólico , Suínos
6.
Front Cardiovasc Med ; 9: 829546, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35355973

RESUMO

Newborn mammals, including piglets, exhibit natural heart regeneration after myocardial infarction (MI) on postnatal day 1 (P1), but this ability is lost by postnatal day 7 (P7). The electrophysiologic properties of this naturally regenerated myocardium have not been examined. We hypothesized that epicardial conduction is preserved after P1 MI in piglets. Yorkshire-Landrace piglets underwent left anterior descending coronary artery ligation at age P1 (n = 6) or P7 (n = 7), After 7 weeks, cardiac magnetic resonance imaging was performed with late gadolinium enhancement for analysis of fibrosis. Epicardial conduction mapping was performed using custom 3D-printed high-resolution mapping arrays. Age- and weight-matched healthy pigs served as controls (n = 6). At the study endpoint, left ventricular (LV) ejection fraction was similar for controls and P1 pigs (46.4 ± 3.0% vs. 40.3 ± 4.9%, p = 0.132), but significantly depressed for P7 pigs (30.2 ± 6.6%, p < 0.001 vs. control). The percentage of LV myocardial volume consisting of fibrotic scar was 1.0 ± 0.4% in controls, 9.9 ± 4.4% in P1 pigs (p = 0.002 vs. control), and 17.3 ± 4.6% in P7 pigs (p < 0.001 vs. control, p = 0.007 vs. P1). Isochrone activation maps and apex activation time were similar between controls and P1 pigs (9.4 ± 1.6 vs. 7.8 ± 0.9 ms, p = 0.649), but significantly prolonged in P7 pigs (21.3 ± 5.1 ms, p < 0.001 vs. control, p < 0.001 vs. P1). Conduction velocity was similar between controls and P1 pigs (1.0 ± 0.2 vs. 1.1 ± 0.4 mm/ms, p = 0.852), but slower in P7 pigs (0.7 ± 0.2 mm/ms, p = 0.129 vs. control, p = 0.052 vs. P1). Overall, our data suggest that epicardial conduction dynamics are conserved in the setting of natural heart regeneration in piglets after P1 MI.

7.
J Mech Behav Biomed Mater ; 126: 105074, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35030471

RESUMO

After myocardial infarction (MI), adult mammals exhibit scar formation, adverse left ventricular (LV) remodeling, LV stiffening, and impaired contractility, ultimately resulting in heart failure. Neonatal mammals, however, are capable of natural heart regeneration after MI. We hypothesized that neonatal cardiac regeneration conserves native biaxial LV mechanics after MI. Wistar rat neonates (1 day old, n = 46) and adults (8-10 weeks old, n = 20) underwent sham surgery or permanent left anterior descending coronary artery ligation. At 6 weeks after neonatal MI, Masson's trichrome staining revealed negligible fibrosis. Echocardiography for the neonatal MI (n = 15) and sham rats (n = 14) revealed no differences in LV wall thickness or chamber diameter, and both groups had normal ejection fraction (72.7% vs 77.5%, respectively, p = 0.1946). Biaxial tensile testing revealed similar stress-strain curves along both the circumferential and longitudinal axes across a full range of physiologic stresses and strains. The circumferential modulus (267.9 kPa vs 274.2 kPa, p = 0.7847), longitudinal modulus (269.3 kPa vs 277.1 kPa, p = 0.7435), and maximum shear stress (3.30 kPa vs 3.95 kPa, p = 0.5418) did not differ significantly between the neonatal MI and sham groups, respectively. In contrast, transmural scars were observed at 4 weeks after adult MI. Adult MI hearts (n = 7) exhibited profound LV wall thinning (p < 0.0001), chamber dilation (p = 0.0246), and LV dysfunction (ejection fraction 45.4% vs 79.7%, p < 0.0001) compared to adult sham hearts (n = 7). Adult MI hearts were significantly stiffer than adult sham hearts in both the circumferential (321.5 kPa vs 180.0 kPa, p = 0.0111) and longitudinal axes (315.4 kPa vs 172.3 kPa, p = 0.0173), and also exhibited greater maximum shear stress (14.87 kPa vs 3.23 kPa, p = 0.0162). Our study is the first to show that native biaxial LV mechanics are conserved after neonatal heart regeneration following MI, thus adding biomechanical support for the therapeutic potential of cardiac regeneration in the treatment of ischemic heart disease.


Assuntos
Infarto do Miocárdio , Animais , Animais Recém-Nascidos , Fenômenos Biomecânicos , Cicatriz/patologia , Modelos Animais de Doenças , Infarto do Miocárdio/patologia , Miocárdio/patologia , Ratos , Ratos Wistar , Remodelação Ventricular
8.
Acta Biomater ; 151: 414-425, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35995404

RESUMO

Vein grafts, the most commonly used conduits in multi-vessel coronary artery bypass grafting surgery, have high intermediate- and long-term failure rates. The abrupt and marked increase in hemodynamic loads on the vein graft is a known contributor to failure. Recent computational modeling suggests that veins can more successfully adapt to an increase in mechanical load if the rate of loading is gradual. Applying an external wrap or support at the time of surgery is one way to reduce the transmural load, and this approach has improved performance relative to an unsupported vein graft in several animal studies. Yet, a clinical trial in humans has shown benefits and drawbacks, and mechanisms by which an external wrap affects vein graft adaptation remain unknown. This study aims to elucidate such mechanisms using a multimodal experimental and computational data collection pipeline. We quantify morphometry using magnetic resonance imaging, mechanics using biaxial testing, hemodynamics using computational fluid dynamics, structure using histology, and transcriptional changes using bulk RNA-sequencing in an ovine carotid-jugular interposition vein graft model, without and with an external biodegradable wrap that allows loads to increase gradually. We show that a biodegradable external wrap promotes luminal uniformity, physiological wall shear stress, and a consistent vein graft phenotype, namely, it prevents over-distension, over-thickening, intimal hyperplasia, and inflammation, and it preserves mechanotransduction. These mechanobiological insights into vein graft adaptation in the presence of an external support can inform computational growth and remodeling models of external support and facilitate design and manufacturing of next-generation external wrapping devices. STATEMENT OF SIGNIFICANCE: External mechanical support is emerging as a promising technology to prevent vein graft failure following coronary bypass graft surgery. While variants of this technology are currently under investigation in clinical trials, the fundamental mechanisms of adaptation remain poorly understood. We employ an ovine carotid-jugular interposition vein graft model, with and without an external biodegradable wrap to provide mechanical support, and probe vein graft adaptation using a multimodal experimental and computational data collection pipeline. We quantify morphometry using magnetic resonance imaging, mechanics using biaxial testing, fluid flow using computational fluid dynamics, vascular composition and structure using histology, and transcriptional changes using bulk RNA sequencing. We show that the wrap mitigates vein graft failure by promoting multiple adaptive mechanisms (across biological scales).


Assuntos
Mecanotransdução Celular , Túnica Íntima , Animais , Artérias Carótidas/patologia , Artérias Carótidas/cirurgia , Humanos , Hiperplasia/patologia , RNA , Ovinos , Túnica Íntima/patologia , Veias/patologia
9.
J Cardiovasc Transl Res ; 14(2): 283-289, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32495264

RESUMO

Although ex vivo simulation is a valuable tool for surgical optimization, a disease model that mimics human aortic regurgitation (AR) from cusp prolapse is needed to accurately examine valve biomechanics. To simulate AR, four porcine aortic valves were explanted, and the commissure between the two largest leaflets was detached and re-implanted 5 mm lower to induce cusp prolapse. Four additional valves were tested in their native state as controls. All valves were tested in a heart simulator while hemodynamics, high-speed videography, and echocardiography data were collected. Our AR model successfully reproduced cusp prolapse with significant increase in regurgitant volume compared with that of the controls (23.2 ± 8.9 versus 2.8 ± 1.6 ml, p = 0.017). Hemodynamics data confirmed the simulation of physiologic disease conditions. Echocardiography and color flow mapping demonstrated the presence of mild to moderate eccentric regurgitation in our AR model. This novel AR model has enormous potential in the evaluation of valve biomechanics and surgical repair techniques. Graphical Abstract.


Assuntos
Insuficiência da Valva Aórtica/fisiopatologia , Prolapso da Valva Aórtica/fisiopatologia , Valva Aórtica/fisiopatologia , Hemodinâmica , Modelos Cardiovasculares , Animais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Prolapso da Valva Aórtica/diagnóstico por imagem , Fenômenos Biomecânicos , Ecocardiografia Doppler em Cores , Desenho de Equipamento , Técnicas In Vitro , Impressão Tridimensional , Sus scrofa , Técnicas de Sutura , Transdutores de Pressão
10.
J Thorac Cardiovasc Surg ; 161(5): 1776-1783, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32249088

RESUMO

OBJECTIVE: Barlow's disease remains challenging to repair, given the complex valvular morphology and lack of quantitative data to compare techniques. Although there have been recent strides in ex vivo evaluation of cardiac mechanics, to our knowledge, there is no disease model that accurately simulates the morphology and pathophysiology of Barlow's disease. The purpose of this study was to design such a model. METHODS: To simulate Barlow's disease, a cross-species ex vivo model was developed. Bovine mitral valves (n = 4) were sewn into a porcine annulus mount to create excess leaflet tissue and elongated chordae. A heart simulator generated physiologic conditions while hemodynamic data, high-speed videography, and chordal force measurements were collected. The regurgitant valves were repaired using nonresectional repair techniques such as neochord placement. RESULTS: The model successfully imitated the complexities of Barlow's disease, including redundant, billowing bileaflet tissues with notable regurgitation. After repair, hemodynamic data confirmed reduction of mitral leakage volume (25.9 ± 2.9 vs 2.1 ± 1.8 mL, P < .001) and strain gauge analysis revealed lower primary chordae forces (0.51 ± 0.17 vs 0.10 ± 0.05 N, P < .001). In addition, the maximum rate of change of force was significantly lower postrepair for both primary (30.80 ± 11.38 vs 8.59 ± 4.83 N/s, P < .001) and secondary chordae (33.52 ± 10.59 vs 19.07 ± 7.00 N/s, P = .006). CONCLUSIONS: This study provides insight into the biomechanics of Barlow's disease, including sharply fluctuating force profiles experienced by elongated chordae prerepair, as well as restoration of primary chordae forces postrepair. Our disease model facilitates further in-depth analyses to optimize the repair of Barlow's disease.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Prolapso da Valva Mitral , Valva Mitral , Modelos Cardiovasculares , Animais , Fenômenos Biomecânicos/fisiologia , Bovinos , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/fisiopatologia , Prolapso da Valva Mitral/cirurgia , Suínos
11.
Med Eng Phys ; 77: 10-18, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32008935

RESUMO

Mitral regurgitation (MR) due to annular dilation occurs in a variety of mitral valve diseases and is observed in many patients with heart failure due to mitral regurgitation. To understand the biomechanics of MR and ultimately design an optimized annuloplasty ring, a representative disease model with asymmetric dilation of the mitral annulus is needed. This work shows the design and implementation of a 3D-printed valve dilation device to preferentially dilate the posterior mitral valve annulus. Porcine mitral valves (n = 3) were sewn into the device and mounted within a left heart simulator that generates physiologic pressures and flows through the valves, while chordal forces were measured. The valves were incrementally dilated, inducing MR, while hemodynamic and force data were collected. Flow analysis demonstrated that MR increased linearly with respect to percent annular dilation when dilation was greater than a 25.6% dilation threshold (p < 0.01). Pre-threshold, dilation did not cause significant increases in regurgitant fraction. Forces on the chordae tendineae increased as dilation increased prior to the identified threshold (p < 0.01); post-threshold, the MR resulted in highly variable forces. Ultimately, this novel dilation device can be used to more accurately model a wide range of MR disease states and their corresponding repair techniques using ex vivo experimentation. In particular, this annular dilation device provides the means to investigate the design and optimization of novel annuloplasty rings.


Assuntos
Dilatação/instrumentação , Insuficiência da Valva Mitral/terapia , Impressão Tridimensional , Animais , Desenho de Equipamento , Hemodinâmica , Insuficiência da Valva Mitral/fisiopatologia , Suínos
12.
Eur J Cardiothorac Surg ; 57(3): 535-544, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31638697

RESUMO

OBJECTIVES: Posterior ventricular anchoring neochordal (PVAN) repair is a non-resectional technique for correcting mitral regurgitation (MR) due to posterior leaflet prolapse, utilizing a single suture anchored in the myocardium behind the leaflet. This technique has demonstrated clinical efficacy, although a theoretical limitation is stability of the anchoring suture. We hypothesize that the PVAN suture positions the leaflet for coaptation, after which forces are distributed evenly with low repair suture forces. METHODS: Porcine mitral valves were mounted in a 3-dimensional-printed heart simulator and chordal forces, haemodynamics and echocardiography were collected at baseline, after inducing MR by severing chordae, and after PVAN repair. Repair suture forces were measured with a force-sensing post positioned to mimic in vivo suture placement. Forces required to pull the myocardial suture free were also determined. RESULTS: Relative primary and secondary chordae forces on both leaflets were elevated during prolapse (P < 0.05). PVAN repair eliminated MR in all valves and normalized chordae forces to baseline levels on anterior primary (0.37 ± 0.23 to 0.22 ± 0.09 N, P < 0.05), posterior primary (0.62 ± 0.37 to 0.14 ± 0.05 N, P = 0.001), anterior secondary (1.48 ± 0.52 to 0.85 ± 0.43 N, P < 0.001) and posterior secondary chordae (1.42 ± 0.69 to 0.59 ± 0.17 N, P = 0.005). Repair suture forces were minimal, even compared to normal primary chordae forces (0.08 ± 0.04 vs 0.19 ± 0.08 N, P = 0.002), and were 90 times smaller than maximum forces tolerated by the myocardium (0.08 ± 0.04 vs 6.9 ± 1.3 N, P < 0.001). DISCUSSION: PVAN repair eliminates MR by positioning the posterior leaflet for coaptation, distributing forces throughout the valve. Given extremely low measured forces, the strength of the repair suture and the myocardium is not a limitation.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Animais , Cordas Tendinosas/diagnóstico por imagem , Cordas Tendinosas/cirurgia , Hemodinâmica , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Suínos
13.
J R Soc Interface ; 17(173): 20200614, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33259750

RESUMO

Papillary muscles serve as attachment points for chordae tendineae which anchor and position mitral valve leaflets for proper coaptation. As the ventricle contracts, the papillary muscles translate and rotate, impacting chordae and leaflet kinematics; this motion can be significantly affected in a diseased heart. In ex vivo heart simulation, an explanted valve is subjected to physiologic conditions and can be adapted to mimic a disease state, thus providing a valuable tool to quantitatively analyse biomechanics and optimize surgical valve repair. However, without the inclusion of papillary muscle motion, current simulators are limited in their ability to accurately replicate cardiac biomechanics. We developed and implemented image-guided papillary muscle (IPM) robots to mimic the precise motion of papillary muscles. The IPM robotic system was designed with six degrees of freedom to fully capture the native motion. Mathematical analysis was used to avoid singularity conditions, and a supercomputing cluster enabled the calculation of the system's reachable workspace. The IPM robots were implemented in our heart simulator with motion prescribed by high-resolution human computed tomography images, revealing that papillary muscle motion significantly impacts the chordae force profile. Our IPM robotic system represents a significant advancement for ex vivo simulation, enabling more reliable cardiac simulations and repair optimizations.


Assuntos
Insuficiência da Valva Mitral , Robótica , Biomimética , Cordas Tendinosas , Humanos , Músculos Papilares
14.
Cells ; 9(1)2020 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-31963369

RESUMO

Newborn mice and piglets exhibit natural heart regeneration after myocardial infarction (MI). Discovering other mammals with this ability would provide evidence that neonatal cardiac regeneration after MI may be a conserved phenotype, which if activated in adults could open new options for treating ischemic cardiomyopathy in humans. Here, we hypothesized that newborn rats undergo natural heart regeneration after MI. Using a neonatal rat MI model, we performed left anterior descending coronary artery ligation or sham surgery in one-day-old rats under hypothermic circulatory arrest (n = 74). Operative survival was 97.3%. At 1 day post-surgery, rats in the MI group exhibited significantly reduced ejection fraction (EF) compared to shams (87.1% vs. 53.0%, p < 0.0001). At 3 weeks post-surgery, rats in the sham and MI groups demonstrated no difference in EF (71.1% vs. 69.2%, respectively, p = 0.2511), left ventricular wall thickness (p = 0.9458), or chamber diameter (p = 0.7801). Masson's trichome and picrosirius red staining revealed minimal collagen scar after MI. Increased numbers of cardiomyocytes positive for 5-ethynyl-2'-deoxyuridine (p = 0.0072), Ki-67 (p = 0.0340), and aurora B kinase (p = 0.0430) were observed within the peri-infarct region after MI, indicating ischemia-induced cardiomyocyte proliferation. Overall, we present a neonatal rat MI model and demonstrate that newborn rats are capable of endogenous neocardiomyogenesis after MI.


Assuntos
Infarto do Miocárdio/fisiopatologia , Regeneração , Animais , Animais Recém-Nascidos , Aurora Quinase B/metabolismo , Proliferação de Células , Cicatriz/patologia , Colágeno/metabolismo , Modelos Animais de Doenças , Eletrocardiografia , Feminino , Fibrose , Antígeno Ki-67/metabolismo , Ligadura , Masculino , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/patologia , Infarto do Miocárdio/cirurgia , Miócitos Cardíacos/patologia , Ratos Wistar , Fatores de Tempo , Troponina/metabolismo
15.
Microb Biotechnol ; 13(6): 1780-1792, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32476224

RESUMO

The cyanobacterium Synechococcus elongatus (SE) has been shown to rescue ischaemic heart muscle after myocardial infarction by photosynthetic oxygen production. Here, we investigated SE toxicity and hypothesized that systemic SE exposure does not elicit a significant immune response in rats. Wistar rats intravenously received SE (n = 12), sterile saline (n = 12) or E. coli lipopolysaccharide (LPS, n = 4), and a subset (8 SE, 8 saline) received a repeat injection 4 weeks later. At baseline, 4 h, 24 h, 48 h, 8 days and 4 weeks after injection, clinical assessments, blood cultures, blood counts, lymphocyte phenotypes, liver function tests, proinflammatory cytokines and immunoglobulins were assessed. Across all metrics, SE rats responded comparably to saline controls, displaying no clinically significant immune response. As expected, LPS rats exhibited severe immunological responses. Systemic SE administration does not induce sepsis or toxicity in rats, thereby supporting the safety of cyanobacteria-mammalian symbiotic therapeutics using this organism.


Assuntos
Escherichia coli , Synechococcus , Animais , Fotossíntese , Ratos , Ratos Wistar
16.
Sci Rep ; 10(1): 7319, 2020 04 30.
Artigo em Inglês | MEDLINE | ID: mdl-32355240

RESUMO

Neonatal mice exhibit natural heart regeneration after myocardial infarction (MI) on postnatal day 1 (P1), but this ability is lost by postnatal day 7 (P7). Cardiac biomechanics intricately affect long-term heart function, but whether regenerated cardiac muscle is biomechanically similar to native myocardium remains unknown. We hypothesized that neonatal heart regeneration preserves native left ventricular (LV) biomechanical properties after MI. C57BL/6J mice underwent sham surgery or left anterior descending coronary artery ligation at age P1 or P7. Echocardiography performed 4 weeks post-MI showed that P1 MI and sham mice (n = 22, each) had similar LV wall thickness, diameter, and ejection fraction (59.6% vs 60.7%, p = 0.6514). Compared to P7 shams (n = 20), P7 MI mice (n = 20) had significant LV wall thinning, chamber enlargement, and depressed ejection fraction (32.6% vs 61.8%, p < 0.0001). Afterward, the LV was explanted and pressurized ex vivo, and the multiaxial lenticular stress-strain relationship was tracked. While LV tissue modulus for P1 MI and sham mice were similar (341.9 kPa vs 363.4 kPa, p = 0.6140), the modulus for P7 MI mice was significantly greater than that for P7 shams (691.6 kPa vs 429.2 kPa, p = 0.0194). We conclude that, in neonatal mice, regenerated LV muscle has similar biomechanical properties as native LV myocardium.


Assuntos
Ventrículos do Coração/fisiopatologia , Coração/fisiologia , Infarto do Miocárdio/patologia , Miocárdio/patologia , Regeneração , Animais , Animais Recém-Nascidos , Fenômenos Biomecânicos , Proliferação de Células , Colágeno/química , Ecocardiografia , Feminino , Camundongos , Camundongos Endogâmicos C57BL , Miócitos Cardíacos/citologia , Estresse Mecânico , Remodelação Ventricular
17.
Adv Healthc Mater ; 8(5): e1801147, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30714355

RESUMO

Hydrogels have emerged as a diverse class of biomaterials offering a broad range of biomedical applications. Specifically, injectable hydrogels are advantageous for minimally invasive delivery of various therapeutics and have great potential to treat a number of diseases. However, most current injectable hydrogels are limited by difficult and time-consuming fabrication techniques and are unable to be delivered through long, narrow catheters, preventing extensive clinical translation. Here, the development of an easily-scaled, catheter-injectable hydrogel utilizing a polymer-nanoparticle crosslinking mechanism is reported, which exhibits notable shear-thinning and self-healing behavior. Gelation of the hydrogel occurs immediately upon mixing the biochemically modified hyaluronic acid polymer with biodegradable nanoparticles and can be easily injected through a high-gauge syringe due to the dynamic nature of the strong, yet reversible crosslinks. Furthermore, the ability to deliver this novel hydrogel through a long, narrow, physiologically-relevant catheter affixed with a 28-G needle is highlighted, with hydrogel mechanics unchanged after delivery. Due to the composition of the gel, it is demonstrated that therapeutics can be differentially released with distinct elution profiles, allowing precise control over drug delivery. Finally, the cell-signaling and biocompatibility properties of this innovative hydrogel are demonstrated, revealing its wide range of therapeutic applications.


Assuntos
Materiais Biocompatíveis/química , Hidrogéis/química , Animais , Linhagem Celular , Sistemas de Liberação de Medicamentos/métodos , Humanos , Masculino , Camundongos , Células NIH 3T3 , Polímeros/química , Ratos , Ratos Wistar , Engenharia Tecidual/métodos
18.
Ann Thorac Surg ; 108(1): 90-97, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30836099

RESUMO

BACKGROUND: Neochordoplasty is an important repair technique, but optimal anchoring position is unknown. Although typically anchored at papillary muscles, new percutaneous devices anchor the neochordae at or near the ventricular apex, which may have an effect on chordal forces and the long-term durability of the repair. METHODS: Porcine mitral valves (n = 6) were mounted in a left heart simulator that generates physiologic pressure and flow through the valves, and chordal forces were measured with Fiber Bragg Grating strain gauge sensors. Isolated mitral regurgitation was induced by cutting P2 primary chordae, and the regurgitant valve was repaired with polytetrafluoroethylene neochord with apical anchoring, followed by papillary muscle fixation for comparison. In both situations, the neochord was anchored to a customized force-sensing post positioned to mimic the relevant in vivo placement. RESULTS: Echocardiographic and hemodynamic data confirmed that the repairs restored physiologic hemodynamics. Forces on the chordae and neochord were lower for papillary fixation than for the apical fixation (p = 0.003). In addition, the maximum rate of change of force on the chordae and neochordae was higher for apical fixation than for papillary fixation (p = 0.028). CONCLUSIONS: Apical neochord anchoring results in effective repair of mitral regurgitation, albeit with somewhat higher forces on the chordae and neochord suture, as well as an increased rate of loading on the neochord compared with the papillary muscle fixation. These results may guide strategies to reduce stresses on neochordae as well as aid optimal patient selection.


Assuntos
Cordas Tendinosas/cirurgia , Insuficiência da Valva Mitral/cirurgia , Animais , Fenômenos Biomecânicos , Cordas Tendinosas/fisiologia , Ecocardiografia , Hemodinâmica , Insuficiência da Valva Mitral/fisiopatologia , Músculos Papilares/cirurgia , Suínos
19.
J Mech Behav Biomed Mater ; 96: 165-171, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31035067

RESUMO

Adverse remodeling of the left ventricle (LV) after myocardial infarction (MI) results in abnormal tissue biomechanics and impaired cardiac function, often leading to heart failure. We hypothesized that intramyocardial delivery of engineered stromal cell-derived factor 1α analog (ESA), our previously-developed supra-efficient pro-angiogenic chemokine, preserves biaxial LV mechanical properties after MI. Male Wistar rats (n = 45) underwent sham surgery (n = 15) or permanent left anterior descending coronary artery ligation. Rats sustaining MI were randomized for intramyocardial injections of either saline (100 µL, n = 15) or ESA (6 µg/kg, n = 15), delivered at four standardized borderzone sites. After 4 weeks, echocardiography was performed, and the hearts were explanted. Tensile testing of the anterolateral LV wall was performed using a displacement-controlled biaxial load frame, and modulus was determined after constitutive modeling. At 4 weeks post-MI, compared to saline controls, ESA-treated hearts had greater wall thickness (1.68 ±â€¯0.05 mm vs 1.42 ±â€¯0.08 mm, p = 0.008), smaller end-diastolic LV internal dimension (6.88 ±â€¯0.29 mm vs 7.69 ±â€¯0.22 mm, p = 0.044), and improved ejection fraction (62.8 ±â€¯3.0% vs 49.4 ±â€¯4.5%, p = 0.014). Histologic analysis revealed significantly reduced infarct size for ESA-treated hearts compared to saline controls (29.4 ±â€¯2.9% vs 41.6 ±â€¯3.1%, p = 0.021). Infarcted hearts treated with ESA exhibited decreased modulus compared to those treated with saline in both the circumferential (211.5 ±â€¯6.9 kPa vs 264.3 ±â€¯12.5 kPa, p = 0.001) and longitudinal axes (194.5 ±â€¯6.5 kPa vs 258.1 ±â€¯14.4 kPa, p < 0.001). In both principal directions, ESA-treated infarcted hearts possessed similar tissue compliance as sham non-infarcted hearts. Overall, intramyocardial ESA therapy improves post-MI ventricular remodeling and function, reduces infarct size, and preserves native LV biaxial mechanical properties.


Assuntos
Quimiocina CXCL12/genética , Quimiocina CXCL12/farmacologia , Coração/efeitos dos fármacos , Coração/fisiopatologia , Fenômenos Mecânicos/efeitos dos fármacos , Infarto do Miocárdio/fisiopatologia , Engenharia de Proteínas , Animais , Fenômenos Biomecânicos/efeitos dos fármacos , Masculino , Ratos , Ratos Wistar , Remodelação Ventricular/efeitos dos fármacos
20.
Nat Biomed Eng ; 3(8): 611-620, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31391596

RESUMO

Post-operative adhesions form as a result of normal wound healing processes following any type of surgery. In cardiac surgery, pericardial adhesions are particularly problematic during reoperations, as surgeons must release the adhesions from the surface of the heart before the intended procedure can begin, thereby substantially lengthening operation times and introducing risks of haemorrhage and injury to the heart and lungs during sternal re-entry and cardiac dissection. Here we show that a dynamically crosslinked supramolecular polymer-nanoparticle hydrogel, with viscoelastic and flow properties that enable spraying onto tissue as well as robust tissue adherence and local retention in vivo for two weeks, reduces the formation of pericardial adhesions. In a rat model of severe pericardial adhesions, the hydrogel markedly reduced the severity of the adhesions, whereas commercial adhesion barriers (including Seprafilm and Interceed) did not. The hydrogels also reduced the severity of cardiac adhesions (relative to untreated animals) in a clinically relevant cardiopulmonary-bypass model in sheep. This viscoelastic supramolecular polymeric hydrogel represents a promising clinical solution for the prevention of post-operative pericardial adhesions.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Hidrogéis/química , Pericárdio/cirurgia , Polímeros/química , Aderências Teciduais , Animais , Celulose Oxidada , Ácido Hialurônico , Hidrogéis/uso terapêutico , Masculino , Modelos Animais , Nanopartículas , Polímeros/uso terapêutico , Ratos , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA