Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Cancer Cell Int ; 23(1): 333, 2023 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-38115111

RESUMO

DPY30 belongs to the core subunit of components of the histone lysine methyltransferase complex, which is implicated in tumorigenesis, cell senescence, and other biological events. However, its contribution to colorectal carcinoma (CRC) progression and metastasis has yet to be elucidated. Therefore, this study aimed to investigate the biological function of DPY30 in CRC metastasis both in vitro and in vivo. Herein, our results revealed that DPY30 overexpression is significantly positively correlated with positive lymph nodes, epithelial-mesenchymal transition (EMT), and CRC metastasis. Moreover, DPY30 knockdown in HT29 and SW480 cells markedly decreased EMT progression, as well as the migratory and invasive abilities of CRC cells in vitro and lung tumor metastasis in vivo. Mechanistically, DPY30 increased histone H3K4me3 level and promoted EMT and CRC metastasis by upregulating the transcriptional expression of ZEB1. Taken together, our findings indicate that DPY30 may serve as a therapeutic target and prognostic marker for CRC.

2.
Int J Med Sci ; 20(7): 901-917, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37324189

RESUMO

DPY30, a core subunit of the SET1/MLL histone H3K4 methyltransferase complexes, plays an important role in diverse biological functions through the epigenetic regulation of gene transcription, especially in cancer development. However, its involvement in human colorectal carcinoma (CRC) has not been elucidated yet. Here we demonstrated that DPY30 was overexpressed in CRC tissues, and significantly associated with pathological grading, tumor size, TNM stage, and tumor location. Furthermore, DPY30 knockdown remarkably suppressed the CRC cell proliferation through downregulation of PCNA and Ki67 in vitro and in vivo, simultaneously induced cell cycle arrest at S phase by downregulating Cyclin A2. In the mechanistic study, RNA-Seq analysis revealed that enriched gene ontology of cell proliferation and cell growth was significantly affected. And ChIP result indicated that DPY30 knockdown inhibited H3 lysine 4 trimethylation (H3K4me3) and attenuated interactions between H3K4me3 with PCNA, Ki67 and cyclin A2 respectively, which led to the decrease of H3K4me3 establishment on their promoter regions. Taken together, our results demonstrate overexpression of DPY30 promotes CRC cell proliferation and cell cycle progression by facilitating the transcription of PCNA, Ki67 and cyclin A2 via mediating H3K4me3. It suggests that DPY30 may serve as a potential therapeutic molecular target for CRC.


Assuntos
Neoplasias Colorretais , Ciclina A2 , Humanos , Ciclina A2/genética , Fatores de Transcrição , Epigênese Genética , Antígeno Ki-67 , Antígeno Nuclear de Célula em Proliferação , Proliferação de Células/genética , Ciclo Celular/genética , Neoplasias Colorretais/genética
3.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 53(3): 504-510, 2022 May.
Artigo em Zh | MEDLINE | ID: mdl-35642162

RESUMO

Objective: To establish a method for quantitative analysis of haloacetic acids (HAAs), disinfection byproducts, in tap water with reversed-phase ultra-performance liquid chromatography-quadrupole-orbitrap high resolution mass spectrometry. Methods: Tap water samples were collected and 0.70 g/L ascorbic acid was added to eliminate residual chlorine. Then, the water samples were directly injected into the instrument for analysis after filtration. After separation on a pentafluorobenzene (PFP) column with an inner diameter of 1.0 mm at a higher linear velocity and a lower volume flow rate compared with those of a narrow-bore column, nine HAAs, namely, monochloroacetic acid (MCAA), monobromoacetic acid (MBAA), dichloroacetic acid (DCAA), bromochloroacetic acid (BCAA), dibromoacetic acid (DBAA), trichloroacetic acid (TCAA), bromodichloroacetic acid(BDCAA), chlorodibromoacetic acid (CDBAA) and tribromoacetic acid (TBAA), were examined by negative electrospray ionization and full MS/dd-MS 2 acquisition mode. In order to adjust for the matrix effect, matrix matching calibration curves were used to quantitate the nine HAAs. Results: Good linearity was obtained for each of the nine HAAs within their respective linear ranges. The detection limits and quantification limits of the method were 0.020-1.0 µg/L and 0.060-3.0 µg/L. The recoveries were 69.8%-119%. Conclusion: The proposed method showed strengths in separation speed and qualitative accuracy. It did not require for complicated pretreatment procedures and can meet the need of tap water sample analysis.


Assuntos
Desinfecção , Água , Cromatografia Líquida , Espectrometria de Massas em Tandem/métodos , Água/análise , Água/química
4.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 53(2): 327-334, 2022 Mar.
Artigo em Zh | MEDLINE | ID: mdl-35332738

RESUMO

Objective: To establish a high-performance liquid chromatography orbital trap mass spectrometry (HPLC-Obitrap MS) method for screening 34 common drugs and metabolites in biological samples. Methods: The target analytes in urine and blood samples were extracted with ethyl acetate, concentrated by nitrogen blowing and redissolved. The hair samples were washed with water and acetone, dried and cut into bits of about 1 mm, and then crushed in a freezing grinder. The analytes were extracted with methanol, and after filtration, the filtrate was used for instrumental analysis. Hypersil Gold PFP (2.1 mm×100 mm, 3 µm) column was used for chromatographic separation. Methanol and 5 mmol/L ammonium acetate solution were used as mobile phase with gradient elution at a flow rate of 400 µL/min. Mass spectrometry was done by electrospray positive and negative ion alternation mode. The data were collected using Full MS and Full MS/dd-MS2 mode. Xcalibur 4.0 software was used to control instruments and to collect data, and TraceFinder 3.3 was used for screening and identification. Results: The method's detection limits for 34 drugs and their metabolites in blood, urine and hair samples were 3.30-10700 ng/L, 4.43-5440 ng/L, 0.0350-4.21 µg/kg, respectively. The intra-day and inter-day precisions of the spiked samples at the levels of 5.0, 10, and 20 µg/L were 3.50%-6.00% and 4.18%-9.90%, respectively. A total of 1125 biological samples of urine, blood and hair were collected and screened. The results showed that 96.7% of the drug users were taking a single drug, while 3.3% were mixed drug users. The main types of drug of abuse were methamphetamine (75.8%), heroin (18.5%), ketamine (2.4%) and other drugs (3.3%), and 87.9% of the positive samples were from male users. Compared with the results of high-performance liquid chromatography triple quadrupole mass spectrometry, this method can be used to identify more types of drugs in one run and to conduct retrospective analysis. Conclusion: The method established in the study is simple and sensitive and is well suited for the screening of common drugs and metabolites in biological samples.


Assuntos
Cabelo , Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida , Humanos , Masculino , Estudos Retrospectivos , Espectrometria de Massas em Tandem/métodos
6.
Oncotarget ; 8(50): 87955-87970, 2017 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-29152133

RESUMO

BACKGROUND: Our previous investigations have shown that the variants of X-ray repair complementing 4 (XRCC4) may be involved in hepatocellular carcinoma (hepatocarcinoma) tumorigenesis. This study aimed to investigate the possible prognostic significance of XRCC4 expression for hepatocarcinoma patients and possible value for the selection of transarterial chemoembolization (TACE) treatment. MATERIALS AND METHODS: We conducted a hospital-based retrospective analysis (including 421 hepatocarcinoma cases) to analyze the effects of XRCC4 on hepatocarcinoma prognosis and TACE. The levels of XRCC4 expression were tested using immunohistochemistry. The sensitivity of cancer cells to anti-cancer drug doxorubicin was evaluated using the half-maximal inhibitory concentration (IC50). RESULTS: XRCC4 expression was significantly correlated with pathological features including tumor stage, liver cirrhosis, and micro-vessel density. XRCC4 expression was an independent prognostic factor of hepatocarcinoma, and TACE treatments had no effects on prognosis of hepatocarcinoma patients with high XRCC4 expression. More intriguingly, TACE improved the prognosis of hepatocarcinoma patients with low XRCC4 expression. Functionally, XRCC4 overexpression increased while XRCC4 knockdown reduced the IC50 of cancer cells to doxorubicin. CONCLUSIONS: These results suggest that XRCC4 may be an independent prognostic factor for hepatocarcinoma patients, and that decreasing XRCC4 expression may be beneficial for post-operative adjuvant TACE treatment in hepatocarcinoma.

7.
J Chromatogr Sci ; 53(6): 925-31, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25480455

RESUMO

A comprehensive ultra-high performance liquid chromatography/tandem mass spectrometry (UHPLC/MS/MS) procedure for detection of nine ß-agonists in animal-derived food is described. The method was based on enzymatic hydrolysis with ß-glucuronidase from Helix pomatia, followed by a liquid-liquid extraction procedure with perchloric acid and a solid-phase extraction scheme using two kinds of cartridges, HLB and MCX. The influence of sample solution pH in the extraction recovery was studied, and pH 4.0 was found to give the best recovery. The analytes were eluted with methanol containing 4% ammonia. A validation procedure for quantitative analysis of ß-agonists in animal-derived food was performed. The three kinds of internal standards, d3-salbutamol, d6-ractopamine and d9-clenpenterol, were applied in the sample preparation and detection of UHPLC/MS/MS. The recoveries from spiked samples ranged between 74.9 and 106.9%. The relative standard deviations of detection were at 0.7-9.6%. The limits of detection and quantification were 0.01-0.05 and 0.03-0.20 µg/kg, respectively. The effect of sample matrix in the detection was discussed in detail.


Assuntos
Agonistas Adrenérgicos beta/análise , Cromatografia Líquida de Alta Pressão/métodos , Resíduos de Drogas/análise , Etanolaminas/análise , Carne/análise , Animais , Cromatografia Líquida/métodos , Rim/química , Limite de Detecção , Modelos Lineares , Fígado/química , Reprodutibilidade dos Testes , Suínos , Espectrometria de Massas em Tandem/métodos , Drogas Veterinárias/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA