Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Acoust Soc Am ; 141(3): 1900, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28372093

RESUMO

A modified generalized sidelobe canceller (IGSC) algorithm is proposed to enhance the resolution and robustness against the noise of the traditional generalized sidelobe canceller (GSC) and coherence factor combined method (GSC-CF). In the GSC algorithm, weighting vector is divided into adaptive and non-adaptive parts, while the non-adaptive part does not block all the desired signal. A modified steer vector of the IGSC algorithm is generated by the projection of the non-adaptive vector on the signal space constructed by the covariance matrix of received data. The blocking matrix is generated based on the orthogonal complementary space of the modified steer vector and the weighting vector is updated subsequently. The performance of IGSC was investigated by simulations and experiments. Through simulations, IGSC outperformed GSC-CF in terms of spatial resolution by 0.1 mm regardless there is noise or not, as well as the contrast ratio respect. The proposed IGSC can be further improved by combining with CF. The experimental results also validated the effectiveness of the proposed algorithm with dataset provided by the University of Michigan.


Assuntos
Algoritmos , Cistos/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Ondas Ultrassônicas , Ultrassonografia/métodos , Simulação por Computador , Modelos Teóricos , Movimento (Física) , Imagens de Fantasmas , Ultrassonografia/instrumentação
2.
J Acoust Soc Am ; 142(1): 240, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-28764415

RESUMO

It is possible to recover a signal below the Nyquist sampling limit using a compressive sensing technique in ultrasound imaging. However, the reconstruction enabled by common sparse transform approaches does not achieve satisfactory results. Considering the ultrasound echo signal's features of attenuation, repetition, and superposition, a sparse dictionary with the emission pulse signal is proposed. Sparse coefficients in the proposed dictionary have high sparsity. Images reconstructed with this dictionary were compared with those obtained with the three other common transforms, namely, discrete Fourier transform, discrete cosine transform, and discrete wavelet transform. The performance of the proposed dictionary was analyzed via a simulation and experimental data. The mean absolute error (MAE) was used to quantify the quality of the reconstructions. Experimental results indicate that the MAE associated with the proposed dictionary was always the smallest, the reconstruction time required was the shortest, and the lateral resolution and contrast of the reconstructed images were also the closest to the original images. The proposed sparse dictionary performed better than the other three sparse transforms. With the same sampling rate, the proposed dictionary achieved excellent reconstruction quality.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA