BMC Med Imaging ; 24(1): 4, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166655

RESUMO

BACKGROUND: Susac syndrome (SuS) is a rare autoimmune disease that leads to hearing impairment, visual field deficits, and encephalopathy due to an occlusion of precapillary arterioles in the brain, retina, and inner ear. Given the potentially disastrous outcome and difficulties in distinguishing SuS from its differential diagnoses, such as multiple sclerosis (MS), our exploratory study aimed at identifying potential new SuS-specific neuroimaging markers. METHODS: Seven patients with a definite diagnosis of SuS underwent magnetic resonance imaging (MRI) at 7 Tesla (7T), including T2* weighted and quantitative susceptibility mapping (QSM) sequences. T2 weighted hyperintense lesions were analyzed with regard to number, volume, localization, central vein sign, T1 hypointensity, and focal iron deposits in the center of SuS lesions ("iron dots"). Seven T MRI datasets from the same institute, comprising 75 patients with, among others, MS, served as controls. RESULTS: The "iron dot" sign was present in 71.4% (5/7) of the SuS patients, compared to 0% in our control cohort. Thus, sensitivity was 71.4% and specificity 100%. A central vein sign was only incidentally detected. CONCLUSION: We are the first to demonstrate this type of "iron dot" lesions on highly resolving 7T T2*w and QSM images in vivo as a promising neuroimaging marker of SuS, corroborating previous histopathological ex vivo findings.


Assuntos
Esclerose Múltipla , Síndrome de Susac , Humanos , Síndrome de Susac/diagnóstico por imagem , Síndrome de Susac/patologia , Ferro , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico por imagem
2.
Neuroimage ; 270: 119950, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36822250

RESUMO

Understanding cerebellar alterations due to healthy aging provides a reference point against which pathological findings in late-onset disease, for example spinocerebellar ataxia type 6 (SCA6), can be contrasted. In the present study, we investigated the impact of aging on the cerebellar nuclei and cerebellar cortex in 109 healthy controls (age range: 16 - 78 years) using 3 Tesla magnetic resonance imaging (MRI). Findings were compared with 25 SCA6 patients (age range: 38 - 78 years). A subset of 16 SCA6 (included: 14) patients and 50 controls (included: 45) received an additional MRI scan at 7 Tesla and were re-scanned after one year. MRI included T1-weighted, T2-weighted FLAIR, and multi-echo T2*-weighted imaging. The T2*-weighted phase images were converted to quantitative susceptibility maps (QSM). Since the cerebellar nuclei are characterized by elevated iron content with respect to their surroundings, two independent raters manually outlined them on the susceptibility maps. T1-weighted images acquired at 3T were utilized to automatically identify the cerebellar gray matter (GM) volume. Linear correlations revealed significant atrophy of the cerebellum due to tissue loss of cerebellar cortical GM in healthy controls with increasing age. Reduction of the cerebellar GM was substantially stronger in SCA6 patients. The volume of the dentate nuclei did not exhibit a significant relationship with age, at least in the age range between 18 and 78 years, whereas mean susceptibilities of the dentate nuclei increased with age. As previously shown, the dentate nuclei volumes were smaller and magnetic susceptibilities were lower in SCA6 patients compared to age- and sex-matched controls. The significant dentate volume loss in SCA6 patients could also be confirmed with 7T MRI. Linear mixed effects models and individual paired t-tests accounting for multiple comparisons revealed no statistical significant change in volume and susceptibility of the dentate nuclei after one year in neither patients nor controls. Importantly, dentate volumes were more sensitive to differentiate between SCA6 (Cohen's d = 3.02) and matched controls than the cerebellar cortex volume (d = 2.04). In addition to age-related decline of the cerebellar cortex and atrophy in SCA6 patients, age-related increase of susceptibility of the dentate nuclei was found in controls, whereas dentate volume and susceptibility was significantly decreased in SCA6 patients. Because no significant changes of any of these parameters was found at follow-up, these measures do not allow to monitor disease progression at short intervals.


Assuntos
Ataxias Espinocerebelares , Humanos , Adolescente , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Ataxias Espinocerebelares/diagnóstico por imagem , Ataxias Espinocerebelares/patologia , Cerebelo/patologia , Córtex Cerebelar/diagnóstico por imagem , Córtex Cerebelar/patologia , Núcleos Cerebelares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Atrofia/patologia
3.
Neuroimage ; 253: 119080, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35276369

RESUMO

The cerebellum is involved in the acquisition and consolidation of learned fear responses. Knowledge about its contribution to extinction learning, however, is sparse. Extinction processes likely involve erasure of memories, but there is ample evidence that at least part of the original memory remains. We asked the question whether memory persists within the cerebellum following extinction training. The renewal effect, that is the reoccurrence of the extinguished fear memory during recall in a context different from the extinction context, constitutes one of the phenomena indicating that memory of extinguished learned fear responses is not fully erased during extinction training. We performed a differential AB-A/B fear conditioning paradigm in a 7-Tesla (7T) MRI system in 31 young and healthy men. On day 1, fear acquisition training was performed in context A and extinction training in context B. On day 2, recall was tested in contexts A and B. As expected, participants learned to predict that the CS+ was followed by an aversive electric shock during fear acquisition training. Skin conductance responses (SCRs) were significantly higher to the CS+ compared to the CS- at the end of acquisition. Differences in SCRs vanished in extinction and reoccurred in the acquisition context during recall indicating renewal. Fitting SCR data, a deep neural network model was trained to predict the correct shock value for a given stimulus and context. Event-related fMRI analysis with model-derived prediction values as parametric modulations showed significant effects on activation of the posterolateral cerebellum (lobules VI and Crus I) during recall. Since the prediction values differ based on stimulus (CS+ and CS-) and context during recall, data provide support that the cerebellum is involved in context-related recall of learned fear associations. Likewise, mean ß values were highest in lobules VI and Crus I bilaterally related to the CS+ in the acquisition context during early recall. A similar pattern was seen in the vermis, but only on a trend level. Thus, part of the original memory likely remains within the cerebellum following extinction training. We found cerebellar activations related to the CS+ and CS- during fear acquisition training which likely reflect associative and non-associative aspects of the task. Cerebellar activations, however, were not significantly different for CS+ and CS-. Since the CS- was never followed by an electric shock, the cerebellum may contribute to associative learning related to the CS, for example as a safety cue.


Assuntos
Extinção Psicológica , Medo , Mapeamento Encefálico , Cerebelo/diagnóstico por imagem , Cerebelo/fisiologia , Extinção Psicológica/fisiologia , Medo/fisiologia , Resposta Galvânica da Pele , Humanos , Imageamento por Ressonância Magnética , Masculino
4.
J Neurosci ; 39(33): 6555-6570, 2019 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-31263064

RESUMO

Artificial agents are becoming prevalent across human life domains. However, the neural mechanisms underlying human responses to these new, artificial social partners remain unclear. The uncanny valley (UV) hypothesis predicts that humans prefer anthropomorphic agents but reject them if they become too humanlike-the so-called UV reaction. Using fMRI, we investigated neural activity when subjects evaluated artificial agents and made decisions about them. Across two experimental tasks, the ventromedial prefrontal cortex (VMPFC) encoded an explicit representation of subjects' UV reactions. Specifically, VMPFC signaled the subjective likability of artificial agents as a nonlinear function of humanlikeness, with selective low likability for highly humanlike agents. In exploratory across-subject analyses, these effects explained individual differences in psychophysical evaluations and preference choices. Functionally connected areas encoded critical inputs for these signals: the temporoparietal junction encoded a linear humanlikeness continuum, whereas nonlinear representations of humanlikeness in dorsomedial prefrontal cortex (DMPFC) and fusiform gyrus emphasized a human-nonhuman distinction. Following principles of multisensory integration, multiplicative combination of these signals reconstructed VMPFC's valuation function. During decision making, separate signals in VMPFC and DMPFC encoded subjects' decision variable for choices involving humans or artificial agents, respectively. A distinct amygdala signal predicted rejection of artificial agents. Our data suggest that human reactions toward artificial agents are governed by a neural mechanism that generates a selective, nonlinear valuation in response to a specific feature combination (humanlikeness in nonhuman agents). Thus, a basic principle known from sensory coding-neural feature selectivity from linear-nonlinear transformation-may also underlie human responses to artificial social partners.SIGNIFICANCE STATEMENT Would you trust a robot to make decisions for you? Autonomous artificial agents are increasingly entering our lives, but how the human brain responds to these new artificial social partners remains unclear. The uncanny valley (UV) hypothesis-an influential psychological framework-captures the observation that human responses to artificial agents are nonlinear: we like increasingly anthropomorphic artificial agents, but feel uncomfortable if they become too humanlike. Here we investigated neural activity when humans evaluated artificial agents and made personal decisions about them. Our findings suggest a novel neurobiological conceptualization of human responses toward artificial agents: the UV reaction-a selective dislike of highly humanlike agents-is based on nonlinear value-coding in ventromedial prefrontal cortex, a key component of the brain's reward system.


Assuntos
Comportamento de Escolha/fisiologia , Mentalização/fisiologia , Distância Psicológica , Robótica , Adolescente , Adulto , Inteligência Artificial , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Córtex Pré-Frontal/fisiologia , Adulto Jovem
5.
Stroke ; 51(8): 2505-2513, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32646326

RESUMO

BACKGROUND AND PURPOSE: The pathophysiology of development, growth, and rupture of intracranial aneurysms (IAs) is only partly understood. Cyclooxygenase 2 (COX-2) converts arachidonic acid to prostaglandin H2, which, in turn, is isomerized to prostaglandin E2. In the human body, COX-2 plays an essential role in inflammatory pathways. This explorative study aimed to investigate COX-2 expression in the wall of IAs and its correlation to image features in clinical (1.0T, 1.5T, and 3.0T) magnetic resonance imaging (MRI) and ultra-high-field 7T MRI. METHODS: The study group comprised 40 patients with partly thrombosed saccular IAs. The cohort included 17 ruptured- and 24 unruptured IAs, which had all been treated microsurgically. Formaldehyde-fixed paraffin-embedded samples were immunohistochemically stained with a monoclonal antibody against COX-2 (Dako, Santa Clara, CA; Clone: CX-294). We correlated Perls Prussian blue staining, MRI, and clinical data with immunohistochemistry, analyzed using the Trainable Weka Segmentation algorithm. RESULTS: Aneurysm dome size ranged between 2 and 67 mm. The proportion of COX-2 positive cells ranged between 3.54% to 85.09%. An upregulated COX-2 expression correlated with increasing IA dome size (P=0.047). Furthermore, there was a tendency of higher COX-2 expression in most ruptured IAs (P=0.064). At all field strengths, MRI shows wall hypointensities due to iron deposition correlating with COX-2 expression (P=0.022). CONCLUSIONS: Iron deposition and COX-2 expression in IAs walls correlate with signal hypointensity in MRI, which might, therefore, serve as a biomarker for IA instability. Furthermore, as COX-2 was also expressed in small unruptured IAs, it could be a potential target for specific medical treatment.


Assuntos
Ciclo-Oxigenase 2/biossíntese , Endotélio Vascular/diagnóstico por imagem , Endotélio Vascular/metabolismo , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/metabolismo , Ferro/metabolismo , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Estudos de Coortes , Ciclo-Oxigenase 2/genética , Feminino , Regulação Enzimológica da Expressão Gênica , Humanos , Aneurisma Intracraniano/genética , Masculino , Pessoa de Meia-Idade
6.
Magn Reson Med ; 82(2): 796-810, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30924181

RESUMO

PURPOSE: A 16-channel receive (16Rx) radiofrequency (RF) array for 7T ultra-high field body MR imaging is presented. The coil is evaluated in conjunction with a 16-channel transmit/receive (16TxRx) coil and additionally with a 32-channel transmit/receive (32TxRx) remote body coil for RF transmit and serving as receive references. METHODS: The 16Rx array consists of 16 octagonal overlapping loops connected to custom-built detuning boards with preamplifiers. Performance metrics like noise correlation, g-factors, and signal-to-noise ratio gain were compared between 4 different RF coil configurations. In vivo body imaging was performed in volunteers using radiofrequency shimming, time interleaved acquisition of modes (TIAMO), and 2D spatially selective excitation using parallel transmit (pTx) in the spine. RESULTS: Lower g-factors were obtained when using the 16Rx coil in addition to the 16TxRx array coil configuration versus the 16TxRx array alone. Distinct signal-to-noise ratio gain using the 16Rx coil could be demonstrated in the spine region both for a comparison with the 16TxRx coil (>50% gain) in vivo and the 32TxRx coil (>240% gain) in a phantom. The 16Rx coil was successfully applied to improve anatomical imaging in the abdomen and 2D spatially selective excitation in the spine of volunteers. CONCLUSION: The novel 16-channel Rx-array as an add-on to multichannel TxRx RF coil configurations provides increased signal-to-noise ratio, lower g-factors, and thus improves 7T ultra-high field body MR imaging.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Coluna Vertebral/diagnóstico por imagem , Adulto , Desenho de Equipamento , Humanos , Masculino , Imagens de Fantasmas
7.
Acta Radiol ; 59(3): 296-304, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28691526

RESUMO

Background Considering the currently reported association between a repetitive application and cumulative dosage of Gadolinium (Gd)-based contrast agents and Gd-deposition in brain tissue as well as the risk for the advent of nephrogenic systemic fibrosis (NSF), techniques allowing for a dose reduction become an important key aspect aside from non-enhanced magnetic resonance angiography (MRA) techniques. Thus, this study was focused on the reduction and/or complete omission of contrast agent for renal MRA at 7T. Purpose To evaluate the performance of time-of-flight MRA versus low-dose contrast-enhanced (CE) renal MRA at 7T. Material and Methods Ten healthy volunteers were examined on a 7T MR system comprising a TOF MRA and three-dimensional (3D) fast low angle shot spoiled gradient-echo sequence (FLASH) MRA after administration of one-quarter of clinical dose of gadobutrol. Qualitative image analysis was performed including overall image quality, artery delineation and presence of artifacts. Contrast ratio (CR), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) of the renal arteries were calculated. Results TOF MRA and low-CE MRA achieved comparable overall ratings, with slightly superior delineation of the main renal arteries in TOF MRA (TOF = 3.10 ± 0.75, low-CE = 2.95 ± 0.75). Segmental branches outside and inside the parenchyma were delineated significantly better on TOF MRA. Quantitative analysis demonstrated the superiority of TOF MRA, yielding higher scores for CR, SNR, and CNR. Conclusion The initial results of our study demonstrate the feasibility and comparable diagnostic performance of TOF and low-dose CE renal MRA at 7T.


Assuntos
Meios de Contraste , Angiografia por Ressonância Magnética/métodos , Artéria Renal/diagnóstico por imagem , Adulto , Estudos de Viabilidade , Feminino , Humanos , Aumento da Imagem , Masculino , Adulto Jovem
8.
Hum Brain Mapp ; 38(8): 3957-3974, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-28474470

RESUMO

Classical delay eyeblink conditioning is likely the most commonly used paradigm to study cerebellar learning. As yet, few studies have focused on extinction and savings of conditioned eyeblink responses (CRs). Saving effects, which are reflected in a reacquisition after extinction that is faster than the initial acquisition, suggest that learned associations are at least partly preserved during extinction. In this study, we tested the hypothesis that acquisition-related plasticity is nihilated during extinction in the cerebellar cortex, but retained in the cerebellar nuclei, allowing for faster reacquisition. Changes of 7 T functional magnetic resonance imaging (fMRI) signals were investigated in the cerebellar cortex and nuclei of young and healthy human subjects. Main effects of acquisition, extinction, and reacquisition against rest were calculated in conditioned stimulus-only trials. First-level ß values were determined for a spherical region of interest (ROI) around the acquisition peak voxel in lobule VI, and dentate and interposed nuclei ipsilateral to the unconditioned stimulus. In the cerebellar cortex and nuclei, fMRI signals were significantly lower in extinction compared to acquisition and reacquisition, but not significantly different between acquisition and reacquisition. These findings are consistent with the theory of bidirectional learning in both the cerebellar cortex and nuclei. It cannot explain, however, why conditioned responses reappear almost immediately in reacquisition following extinction. Although the present data do not exclude that part of the initial memory remains in the cerebellum in extinction, future studies should also explore changes in extracerebellar regions as a potential substrate of saving effects. Hum Brain Mapp 38:3957-3974, 2017. © 2017 Wiley Periodicals, Inc.


Assuntos
Córtex Cerebelar/fisiologia , Condicionamento Palpebral/fisiologia , Extinção Psicológica/fisiologia , Imageamento por Ressonância Magnética , Adolescente , Adulto , Análise de Variância , Piscadela/fisiologia , Mapeamento Encefálico , Córtex Cerebelar/diagnóstico por imagem , Núcleos Cerebelares/diagnóstico por imagem , Núcleos Cerebelares/fisiologia , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Testes Neuropsicológicos , Adulto Jovem
9.
Eur Radiol ; 27(3): 1004-1011, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27300194

RESUMO

OBJECTIVES: To assess the image quality of sparsely sampled contrast-enhanced MR angiography (sparse CE-MRA) providing high spatial resolution and whole-head coverage. MATERIALS AND METHODS: Twenty-three patients scheduled for contrast-enhanced MR imaging of the head, (N = 19 with intracranial pathologies, N = 9 with vascular diseases), were included. Sparse CE-MRA at 3 Tesla was conducted using a single dose of contrast agent. Two neuroradiologists independently evaluated the data regarding vascular visibility and diagnostic value of overall 24 parameters and vascular segments on a 5-point ordinary scale (5 = very good, 1 = insufficient vascular visibility). Contrast bolus timing and the resulting arterio-venous overlap was also evaluated. Where available (N = 9), sparse CE-MRA was compared to intracranial Time-of-Flight MRA. RESULTS: The overall rating across all patients for sparse CE-MRA was 3.50 ± 1.07. Direct influence of the contrast bolus timing on the resulting image quality was observed. Overall mean vascular visibility and image quality across different features was rated good to intermediate (3.56 ± 0.95). The average performance of intracranial Time-of-Flight was rated 3.84 ± 0.87 across all patients and 3.54 ± 0.62 across all features. CONCLUSION: Sparse CE-MRA provides high-quality 3D MRA with high spatial resolution and whole-head coverage within short acquisition time. Accurate contrast bolus timing is mandatory. KEY POINTS: • Sparse CE-MRA enables fast vascular imaging with full brain coverage. • Volumes with sub-millimetre resolution can be acquired within 10 seconds. • Reader's ratings are good to intermediate and dependent on contrast bolus timing. • The method provides an excellent overview and allows screening for vascular pathologies.


Assuntos
Meios de Contraste , Aumento da Imagem/métodos , Doenças Arteriais Intracranianas/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Doenças Arteriais Intracranianas/patologia , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Adulto Jovem
10.
MAGMA ; 30(6): 591-607, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28695398

RESUMO

OBJECTIVE: A new technique for 2D gradient-recalled echo echo-planar imaging (GE-EPI) termed 'variable slice thickness' (VAST) is proposed, which reduces signal losses caused by through-slice susceptibility artifacts, while keeping the volume repetition time (TR) manageable. The slice thickness is varied across the brain, with thinner slices being used in the inferior brain regions where signal voids are most severe. MATERIALS AND METHODS: Various axial slice thickness schemes with identical whole-brain coverage were compared to regular EPI, which may either suffer from unfeasibly long TR if appropriately thin slices are used throughout, or signal loss if no counter-measures are taken. Evaluation is based on time-course signal-to-noise (tSNR) maps from resting state data and a statistical group-level region of interest (ROI) analysis on breath-hold fMRI measurements. RESULTS: The inferior brain region signal voids with static B0 inhomogeneities could be markedly reduced with VAST GE-EPI in contrast to regular GE-EPI. ROI-averaged event-related signal changes showed 48% increase in VAST compared to GE-EPI with regular "thick" slices. tSNR measurements proved the comparable signal robustness of VAST in comparison to regular GE-EPI with thin slices. CONCLUSION: A novel acquisition strategy for functional 2D GE-EPI at ultrahigh magnetic field is presented to reduce susceptibility-induced signal voids and keep TR sufficiently short for whole-brain coverage.


Assuntos
Encéfalo/diagnóstico por imagem , Imagem Ecoplanar/métodos , Artefatos , Encéfalo/anatomia & histologia , Encéfalo/fisiologia , Mapeamento Encefálico/métodos , Mapeamento Encefálico/estatística & dados numéricos , Suspensão da Respiração , Imagem Ecoplanar/estatística & dados numéricos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído , Fatores de Tempo
11.
Acta Radiol ; 58(8): 922-928, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28273733

RESUMO

Background Cardiac magnetic resonance imaging (MRI) relies on correct ECG-gating, which is hindered in arrhythmia. Purpose To examine whether a prototype free-breathing real-time cine sequence using SPARSE-SENSE (SPARSE) improves left ventricular quantification in atrial fibrillation. Material and Methods On a 1.5T MR system left ventricular short-axis stacks were acquired of the SPARSE sequence and of a "reference" steady-state free precession (SSFP) sequence with arrhythmia rejection in 20 patients with atrial fibrillation. Two radiologists independently rated arrhythmia-caused artifact severity in both sequences using a 4-point scale. Coefficients of variation of myocardial signal intensity for both sequences were acquired. Volumetry was performed twice by one reader and once by another reader. Correlation between artifact severity and employed sequence was analyzed by modified Fisher's exact test. Coefficients of variation and volumetric data were compared by paired t-test and intraclass correlation. Results Median arrhythmia-caused artifact severity was 2 in both readers for SSFP and 0 (reader 1)/1 (reader 2) for SPARSE, being significantly lower in SPARSE ( P < 0.001). Mean coefficient of variance was significantly smaller in SPARSE (0.11 ± 0.04) compared to SSFP (0.22 ± 0.13, P = 0.003), which was interpreted as a hint for fewer artifacts in SPARSE. Only a small difference of 9 ± 15 mL was seen for end-systolic volume ( P = 0.019) between sequences, otherwise no significant difference was detected (end-diastolic volume, P = 0.200; stroke volume, P = 0.554; ejection fraction, P = 0.136; myocardial mass, P = 0.353). Intraclass correlation between sequences was good to excellent (range, 0.80-0.97). Conclusion Real-time MRI with SPARSE data sampling is promising in atrial fibrillation because it reduces arrhythmia-caused artifacts.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artefatos , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
12.
J Neurosci ; 35(3): 1228-39, 2015 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-25609637

RESUMO

There are controversies whether learning of conditioned eyeblink responses primarily takes place within the cerebellar cortex, the interposed nuclei, or both. It has also been suggested that the cerebellar cortex may be important during early stages of learning, and that there is a shift to the cerebellar nuclei during later stages. As yet, human studies have provided little to resolve this question. In the present study, we established a setup that allows ultra-high-field 7T functional magnetic resonance imaging (fMRI) of the cerebellar cortex and interposed cerebellar nuclei simultaneously during delay eyeblink conditioning in humans. Event-related fMRI signals increased concomitantly in the cerebellar cortex and nuclei during early acquisition of conditioned eyeblink responses in 20 healthy human subjects. ANOVAs with repeated-measures showed significant effects of time across five blocks of 20 conditioning trials in the cortex and nuclei (p < 0.05, permutation corrected). Activations were most pronounced in, but not limited to, lobules VI and interposed nuclei. Increased activations were most prominent at the first time the maximum number of conditioned responses was achieved. Our data are consistent with a simultaneous and synergistic two-site model of learning during acquisition of classically conditioned eyeblinks. Because increased MRI signal reflects synaptic activity, concomitantly increased signals in the cerebellar nuclei and cortex are consistent with findings of learning related potentiation at the mossy fiber to nuclear cell synapse and mossy fiber to granule cell synapse. Activity related to the expression of conditioned responses, however, cannot be excluded.


Assuntos
Córtex Cerebelar/fisiologia , Núcleos Cerebelares/fisiologia , Condicionamento Palpebral/fisiologia , Adulto , Piscadela/fisiologia , Feminino , Neuroimagem Funcional , Humanos , Imageamento por Ressonância Magnética , Masculino , Neurônios/fisiologia , Adulto Jovem
13.
Neuroimage ; 129: 224-232, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-26803060

RESUMO

One type of Internet addiction is excessive pornography consumption, also referred to as cybersex or Internet pornography addiction. Neuroimaging studies found ventral striatum activity when participants watched explicit sexual stimuli compared to non-explicit sexual/erotic material. We now hypothesized that the ventral striatum should respond to preferred pornographic compared to non-preferred pornographic pictures and that the ventral striatum activity in this contrast should be correlated with subjective symptoms of Internet pornography addiction. We studied 19 heterosexual male participants with a picture paradigm including preferred and non-preferred pornographic materials. Subjects had to evaluate each picture with respect to arousal, unpleasantness, and closeness to ideal. Pictures from the preferred category were rated as more arousing, less unpleasant, and closer to ideal. Ventral striatum response was stronger for the preferred condition compared to non-preferred pictures. Ventral striatum activity in this contrast was correlated with the self-reported symptoms of Internet pornography addiction. The subjective symptom severity was also the only significant predictor in a regression analysis with ventral striatum response as dependent variable and subjective symptoms of Internet pornography addiction, general sexual excitability, hypersexual behavior, depression, interpersonal sensitivity, and sexual behavior in the last days as predictors. The results support the role for the ventral striatum in processing reward anticipation and gratification linked to subjectively preferred pornographic material. Mechanisms for reward anticipation in ventral striatum may contribute to a neural explanation of why individuals with certain preferences and sexual fantasies are at-risk for losing their control over Internet pornography consumption.


Assuntos
Comportamento Aditivo/fisiopatologia , Mapeamento Encefálico , Literatura Erótica/psicologia , Comportamento Sexual/fisiologia , Estriado Ventral/fisiologia , Adulto , Nível de Alerta/fisiologia , Humanos , Processamento de Imagem Assistida por Computador , Internet , Imageamento por Ressonância Magnética , Masculino , Estimulação Luminosa , Recompensa , Comportamento Sexual/psicologia , Inquéritos e Questionários
14.
J Magn Reson Imaging ; 44(2): 366-74, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26789014

RESUMO

PURPOSE: To assess two compressed sensing cine magnetic resonance imaging (MRI) sequences with high spatial or high temporal resolution in comparison to a reference steady-state free precession cine (SSFP) sequence for reliable quantification of left ventricular (LV) volumes. MATERIALS AND METHODS: LV short axis stacks of two compressed sensing breath-hold cine sequences with high spatial resolution (SPARSE-SENSE HS: temporal resolution: 40 msec, in-plane resolution: 1.0 × 1.0 mm(2) ) and high temporal resolution (SPARSE-SENSE HT: temporal resolution: 11 msec, in-plane resolution: 1.7 × 1.7 mm(2) ) and of a reference cine SSFP sequence (standard SSFP: temporal resolution: 40 msec, in-plane resolution: 1.7 × 1.7 mm(2) ) were acquired in 16 healthy volunteers on a 1.5T MR system. LV parameters were analyzed semiautomatically twice by one reader and once by a second reader. The volumetric agreement between sequences was analyzed using paired t-test, Bland-Altman plots, and Passing-Bablock regression. RESULTS: Small differences were observed between standard SSFP and SPARSE-SENSE HS for stroke volume (SV; -7 ± 11 ml; P = 0.024), ejection fraction (EF; -2 ± 3%; P = 0.019), and myocardial mass (9 ± 9 g; P = 0.001), but not for end-diastolic volume (EDV; P = 0.079) and end-systolic volume (ESV; P = 0.266). No significant differences were observed between standard SSFP and SPARSE-SENSE HT regarding EDV (P = 0.956), SV (P = 0.088), and EF (P = 0.103), but for ESV (3 ± 5 ml; P = 0.039) and myocardial mass (8 ± 10 ml; P = 0.007). Bland-Altman analysis showed good agreement between the sequences (maximum bias ≤ -8%). CONCLUSION: Two compressed sensing cine sequences, one with high spatial resolution and one with high temporal resolution, showed good agreement with standard SSFP for LV volume assessment. J. Magn. Reson. Imaging 2016;44:366-374.


Assuntos
Algoritmos , Compressão de Dados/métodos , Ventrículos do Coração/diagnóstico por imagem , Aumento da Imagem/métodos , Imagem Cinética por Ressonância Magnética/métodos , Volume Sistólico , Adulto , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Eur Radiol ; 26(12): 4482-4489, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26960537

RESUMO

OBJECTIVES: Improved real-time cardiac magnetic resonance (CMR) sequences have currently been introduced, but so far only limited practical experience exists. This study aimed at image reconstruction optimization and clinical validation of a new highly accelerated real-time cine SPARSE-SENSE sequence. METHODS: Left ventricular (LV) short-axis stacks of a real-time free-breathing SPARSE-SENSE sequence with high spatiotemporal resolution and of a standard segmented cine SSFP sequence were acquired at 1.5 T in 11 volunteers and 15 patients. To determine the optimal iterations, all volunteers' SPARSE-SENSE images were reconstructed using 10-200 iterations, and contrast ratios, image entropies, and reconstruction times were assessed. Subsequently, the patients' SPARSE-SENSE images were reconstructed with the clinically optimal iterations. LV volumetric values were evaluated and compared between both sequences. RESULTS: Sufficient image quality and acceptable reconstruction times were achieved when using 80 iterations. Bland-Altman plots and Passing-Bablok regression showed good agreement for all volumetric parameters. CONCLUSIONS: 80 iterations are recommended for iterative SPARSE-SENSE image reconstruction in clinical routine. Real-time cine SPARSE-SENSE yielded comparable volumetric results as the current standard SSFP sequence. Due to its intrinsic low image acquisition times, real-time cine SPARSE-SENSE imaging with iterative image reconstruction seems to be an attractive alternative for LV function analysis. KEY POINTS: • A highly accelerated real-time CMR sequence using SPARSE-SENSE was evaluated. • SPARSE-SENSE allows free breathing in real-time cardiac cine imaging. • For clinically optimal SPARSE-SENSE image reconstruction, 80 iterations are recommended. • Real-time SPARSE-SENSE imaging yielded comparable volumetric results as the reference SSFP sequence. • The fast SPARSE-SENSE sequence is an attractive alternative to standard SSFP sequences.


Assuntos
Cardiomiopatias/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imagem Cinética por Ressonância Magnética/métodos , Isquemia Miocárdica/diagnóstico por imagem , Miocardite/diagnóstico por imagem , Função Ventricular Esquerda , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Feminino , Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Respiração , Volume Sistólico , Adulto Jovem
16.
Eur Radiol ; 26(3): 829-39, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26080795

RESUMO

OBJECTIVE: To evaluate prospectively 7 Tesla time-of-flight (TOF) magnetic resonance angiography (MRA) and 7 Tesla non-contrast-enhanced magnetization-prepared rapid acquisition gradient-echo (MPRAGE) for delineation of intracerebral arteriovenous malformations (AVMs) in comparison to 1.5 Tesla TOF MRA and digital subtraction angiography (DSA). METHODS: Twenty patients with single or multifocal AVMs were enrolled in this trial. The study protocol comprised 1.5 and 7 Tesla TOF MRA and 7 Tesla non-contrast-enhanced MPRAGE sequences. All patients underwent an additional four-vessel 3D DSA. Image analysis of the following five AVM features was performed individually by two radiologists on a five-point scale: nidus, feeder(s), draining vein(s), relationship to adjacent vessels, and overall image quality and presence of artefacts. RESULTS: A total of 21 intracerebral AVMs were detected. Both sequences at 7 Tesla were rated superior over 1.5 Tesla TOF MRA in the assessment of all considered AVM features. Image quality at 7 Tesla was comparable with DSA considering both sequences. Inter-observer accordance was good to excellent for the majority of ratings. CONCLUSION: This study demonstrates excellent image quality for depiction of intracerebral AVMs using non-contrast-enhanced 7 Tesla MRA, comparable with DSA. Assessment of untreated AVMs is a promising clinical application of ultra-high-field MRA. KEY POINTS: • Non-contrast-enhanced 7 Tesla MRA demonstrates excellent image quality for intracerebral AVM depiction. • Image quality at 7 Tesla was comparable with DSA considering both sequences. • Assessment of intracerebral AVMs is a promising clinical application of ultra-high-field MRA.


Assuntos
Malformações Arteriovenosas Intracranianas/patologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia Digital/métodos , Angiografia Digital/normas , Artefatos , Feminino , Humanos , Angiografia por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Sensibilidade e Especificidade , Adulto Jovem
17.
Brain ; 138(Pt 5): 1182-97, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25818870

RESUMO

Spinocerebellar ataxia type 3, spinocerebellar ataxia type 6 and Friedreich's ataxia are common hereditary ataxias. Different patterns of atrophy of the cerebellar cortex are well known. Data on cerebellar nuclei are sparse. Whereas cerebellar nuclei have long been thought to be preserved in spinocerebellar ataxia type 6, histology shows marked atrophy of the nuclei in Friedreich's ataxia and spinocerebellar ataxia type 3. In the present study susceptibility weighted imaging was used to assess atrophy of the cerebellar nuclei in patients with spinocerebellar ataxia type 6 (n = 12, age range 41-76 years, five female), Friedreich's ataxia (n = 12, age range 21-55 years, seven female), spinocerebellar ataxia type 3 (n = 10, age range 34-67 years, three female), and age- and gender-matched controls (total n = 23, age range 22-75 years, 10 female). T1-weighted magnetic resonance images were used to calculate the volume of the cerebellum. In addition, ultra-high field functional magnetic resonance imaging was performed with optimized normalization methods to assess function of the cerebellar cortex and nuclei during simple hand movements. As expected, the volume of the cerebellum was markedly reduced in spinocerebellar ataxia type 6, preserved in Friedreich's ataxia, and mildy reduced in spinocerebellar ataxia type 3. The volume of the cerebellar nuclei was reduced in the three patient groups compared to matched controls (P-values < 0.05; two-sample t-tests). Atrophy of the cerebellar nuclei was most pronounced in spinocerebellar ataxia type 6. On a functional level, hand-movement-related cerebellar activation was altered in all three disorders. Within the cerebellar cortex, functional magnetic resonance imaging signal was significantly reduced in spinocerebellar ataxia type 6 and Friedreich's ataxia compared to matched controls (P-values < 0.001, bootstrap-corrected cluster-size threshold; two-sample t-tests). The difference missed significance in spinocerebellar ataxia type 3. Within the cerebellar nuclei, reductions were significant when comparing spinocerebellar ataxia type 6 and Friedreich's ataxia to matched controls (P < 0.01, bootstrap-corrected cluster-size threshold; two-sample t-tests). Susceptibility weighted imaging allowed depiction of atrophy of the cerebellar nuclei in patients with Friedreich's ataxia and spinocerebellar ataxia type 3. In spinocerebellar ataxia type 6, pathology was not restricted to the cerebellar cortex but also involved the cerebellar nuclei. Functional magnetic resonance imaging data, on the other hand, revealed that pathology in Friedreich's ataxia and spinocerebellar ataxia type 3 is not restricted to the cerebellar nuclei. There was functional involvement of the cerebellar cortex despite no or little structural changes.


Assuntos
Córtex Cerebelar/patologia , Núcleos Cerebelares/patologia , Ataxia de Friedreich/patologia , Doença de Machado-Joseph/patologia , Imageamento por Ressonância Magnética , Ataxias Espinocerebelares/patologia , Adulto , Idoso , Atrofia , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Degenerações Espinocerebelares/patologia
18.
Biomed Eng Online ; 15(1): 126, 2016 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-27881126

RESUMO

BACKGROUND: Accurate synchronization between magnetic resonance imaging data acquisition and a subject's cardiac activity ("triggering") is essential for reducing image artifacts but conventional, contact-based methods for this task are limited by several factors, including preparation time, patient inconvenience, and susceptibility to signal degradation. The purpose of this work is to evaluate the performance of a new contact-free triggering method developed with the aim to eventually replace conventional methods in non-cardiac imaging applications. In this study, the method's performance is evaluated in the context of 7 Tesla non-enhanced angiography of the lower extremities. METHODS: Our main contribution is a basic algorithm capable of estimating in real-time the phase of the cardiac cycle from reflection photoplethysmography signals obtained from skin color variations of the forehead recorded with a video camera. Instead of finding the algorithm's parameters heuristically, they were optimized using videos of the forehead as well as electrocardiography and pulse oximetry signals that were recorded from eight healthy volunteers in and outside the scanner, with and without active radio frequency and gradient coils. Based on the video characteristics, synthetic signals were generated and the "best available" values of an objective function were determined using mathematical optimization. The performance of the proposed method with optimized algorithm parameters was evaluated by applying it to the recorded videos and comparing the computed triggers to those of contact-based methods. Additionally, the method was evaluated by using its triggers for acquiring images from a healthy volunteer and comparing the result to images obtained using pulse oximetry triggering. RESULTS: During evaluation of the videos recorded inside the bore with active radio frequency and gradient coils, the pulse oximeter triggers were labeled in 62.5% as "potentially usable" for cardiac triggering, the electrocardiography triggers in 12.5%, and the proposed method's triggers in 62.5%. Evaluation of the angiography images demonstrated that under appropriate conditions the method is feasible to produce an image quality comparable to pulse oximetry. CONCLUSION: We conclude that cardiac triggering using the proposed method is technically feasible. However, for improved reliability the signal-to-noise ratio of the videos will have to be addressed by either replacing the camera sensor, improving the illumination, or by use of additional signal filtering techniques.


Assuntos
Eletrocardiografia , Coração/diagnóstico por imagem , Coração/fisiologia , Imageamento por Ressonância Magnética , Oximetria , Fotopletismografia , Processamento de Sinais Assistido por Computador , Adulto , Algoritmos , Angiografia , Artefatos , Feminino , Humanos , Extremidade Inferior/irrigação sanguínea , Masculino , Estudos Prospectivos , Gravação em Vídeo
19.
Magn Reson Med ; 74(6): 1652-60, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25522299

RESUMO

PURPOSE: To integrate, optimize, and evaluate a three-dimensional (3D) contrast-enhanced sparse MRA technique with iterative reconstruction on a standard clinical MR system. METHODS: Data were acquired using a highly undersampled Cartesian spiral phyllotaxis sampling pattern and reconstructed directly on the MR system with an iterative SENSE technique. Undersampling, regularization, and number of iterations of the reconstruction were optimized and validated based on phantom experiments and patient data. Sparse MRA of the whole head (field of view: 265 × 232 × 179 mm(3) ) was investigated in 10 patient examinations. RESULTS: High-quality images with 30-fold undersampling, resulting in 0.7 mm isotropic resolution within 10 s acquisition, were obtained. After optimization of the regularization factor and of the number of iterations of the reconstruction, it was possible to reconstruct images with excellent quality within six minutes per 3D volume. Initial results of sparse contrast-enhanced MRA (CEMRA) in 10 patients demonstrated high-quality whole-head first-pass MRA for both the arterial and venous contrast phases. CONCLUSION: While sparse MRI techniques have not yet reached clinical routine, this study demonstrates the technical feasibility of high-quality sparse CEMRA of the whole head in a clinical setting. Sparse CEMRA has the potential to become a viable alternative where conventional CEMRA is too slow or does not provide sufficient spatial resolution.


Assuntos
Artérias Cerebrais/patologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Algoritmos , Humanos , Angiografia por Ressonância Magnética/instrumentação , Meglumina , Compostos Organometálicos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Tamanho da Amostra , Sensibilidade e Especificidade , Integração de Sistemas
20.
J Magn Reson Imaging ; 42(2): 505-14, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25430957

RESUMO

BACKGROUND: To evaluate the benefit (additional flow information), image quality, and diagnostic accuracy of a dynamic magnetic resonance angiography (MRA) combining high spatial and temporal resolution for the preinterventional assessment of acute aortic dissection. METHODS: Nineteen patients (12 men, 7 women; aged 32-78 years) with acute aortic dissection underwent contrast-enhanced four-dimensional (4D) MRA and 3D conventional high-resolution MRA (3D MRA) within one examination on a 1.5 Tesla MR system. Both MRA datasets for each patient were evaluated and compared for image quality and visualization of vascular details on a 5-point scale (5 = excellent image quality, 1 = nondiagnostic image quality). In addition, presence and relevance of additional hemodynamic information (flow direction and organ perfusion delay) gained by dynamic MRA were assessed. RESULTS: Conventional 3D MRA provided significantly higher values for image quality of the aorta and aortic side branches compared with dynamic MRA (aorta: 4.3 versus 3.3; P = 0.006 side branches: 4.2 versus 3.3; P = 0.02). However, in 10 of the 19 patients (53%) the additionally available information on flow dynamics due to dynamic MRA (e.g., delayed perfusion of parenchymal organs) led to a change in therapy planning and realization. CONCLUSION: Dynamic MRA is a technique that combines functional flow and morphological information. Thus, the combination of 3D and dynamic MRA provides all requested information for treatment planning in patients suffering from acute aortic dissection.


Assuntos
Aneurisma Aórtico/patologia , Aneurisma Aórtico/fisiopatologia , Dissecção Aórtica/patologia , Dissecção Aórtica/fisiopatologia , Velocidade do Fluxo Sanguíneo , Angiografia por Ressonância Magnética/métodos , Doença Aguda , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS