Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J AOAC Int ; 95(6): 1570-3, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23451370

RESUMO

A simple, rapid, economical, and environmentally friendly analytical method was developed for the quantitative assessment of free fatty acids (FFAs) present in deodorizer distillates and crude oils by single bounce-attenuated total reflectance-FTIR spectroscopy. Partial least squares was applied for the calibration model based on the peak region of the carbonyl group (C=O) from 1726 to 1664 cm(-1) associated with the FFAs. The proposed method totally avoided the use of organic solvents or costly standards and could be applied easily in the oil processing industry. The accuracy of the method was checked by comparison to a conventional standard American Oil Chemists' Society (AOCS) titrimetric procedure, which provided good correlation (R = 0.99980), with an SD of +/- 0.05%. Therefore, the proposed method could be used as an alternate to the AOCS titrimetric method for the quantitative determination of FFAs especially in deodorizer distillates.


Assuntos
Desodorantes/análise , Poluentes Ambientais/análise , Ácidos Graxos não Esterificados/análise , Indústria de Processamento de Alimentos , Resíduos Industriais/análise , Calibragem , Indicadores e Reagentes , Padrões de Referência , Reprodutibilidade dos Testes , Solventes , Espectroscopia de Infravermelho com Transformada de Fourier
2.
Artigo em Inglês | MEDLINE | ID: mdl-23831978

RESUMO

A quick and reliable analytical method for the quantitative assessment of cefixime in orally administered pharmaceutical formulations is developed by using diamond cell attenuated total reflectance (ATR) Fourier transform infrared (FT-IR) spectroscopy as an easy procedure for quality control laboratories. The standards for calibration were prepared in aqueous medium ranging from 350 to 6000mg/kg. The calibration model was developed based on partial least square (PLS) using finger print region of FT-IR spectrum in the range from 1485 to 887cm(-1). Excellent coefficient of determination (R(2)) was achieved as high as 0.99976 with root mean square error of 44.8 for calibration. The application of diamond cell (smart accessory) ATR FT-IR proves a reliable determination of cefixime in pharmaceutical formulations to assess the quality of the final product.


Assuntos
Cefixima/análise , Preparações Farmacêuticas/química , Espectroscopia de Infravermelho com Transformada de Fourier/métodos , Administração Oral , Calibragem , Cefixima/química , Cromatografia Líquida de Alta Pressão , Pós/química , Padrões de Referência , Suspensões/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA