Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
1.
J Fluoresc ; 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691279

RESUMO

A novel ratiometric fluorescence probe was developed for the determination of azithromycin (AZM) and sulfide ions based on the differential modulation of red emissive carbon dots (R-N@CDs) and blue emissive carbon dots (B-NS@CDs). The addition of sulfide anion selectively quenched the red emission of R-N@CDs while the blue emission of B-NS@CDs unaffected. Upon subsequent introduction of AZM to this R-N@CDs@sulfide system, the quenched red fluorescence was restored. Comprehensive characterization of the CDs was performed using UV-Vis, fluorescence, FTIR spectroscopy, XPS, and TEM. The proposed method exhibited excellent sensitivity and selectivity, with limits of detection of 0.33 µM for AZM and 0.21 µM for sulfide. Notably, this approach enabled direct detection of sulfide without requiring prior modulation of the CDs with metal ions, as is common in other reported methods. The ratiometric probe was successfully applied for the determination of AZM in biological fluids and sulfide in environmental water samples with high selectivity. This work presents the first fluorometric method for the detection of AZM in biological fluids.

2.
BMC Pregnancy Childbirth ; 24(1): 306, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658860

RESUMO

BACKGROUND: HIV partner counselling and testing in antenatal care (ANC) is a crucial strategy to raise the number of males who know their HIV status. However, in many settings like Tanzania, male involvement in antenatal care remains low, and there is a definite need for innovative strategies to increase male partner involvement. This study was designed to evaluate the efficacy of mobile phone intervention increase male partner ANC attendance for HIV testing in Moshi municipal, Tanzania. METHODS: Between April and July 2022, we enrolled pregnant women presenting to a first ANC visit at Majengo and St. Joseph reproductive health facilities without their male partners. Eligible pregnant women were randomly assigned to invitation of their male partners either via phone calls, text messages from clinic staff and verbal invites from pregnant partners (intervention arm) or verbal invites only from the pregnant partners (control arm). Neither healthcare provider nor participant were blinded. The primary outcome was the proportion of male partners who attended ANC with their pregnant partners during a follow-up period of two consecutive visits. The secondary outcome measure was HIV testing among male partners following the invitation. Participants were analyzed as originally assigned (intention to treat). RESULTS: A total of 350 pregnant women presenting to ANC for the first time were enrolled, with 175 women enrolled in each arm. The efficacy of male attendance with their pregnant women following the invitations was 83.4% (147/175) in the intervention arm and 46.3% (81/175) in the control arm. Overall, the results suggest a positive and statistically significant average treatment effect among men who received mobile phone intervention on ANC attendance. For the secondary outcome, the percent of male partners who accepted HIV counselling and testing was 99.3% (146/147) in the intervention arm and 93.8% (76/81) in the control arm. Married men were having higher odds of ANC attendance compared with single men (aOR:6.40(3.26-12.56), Males with multigravida women were having lower odds of ANC attendance compared with primigravida women (aOR:0.17(0.09-0.33). CONCLUSION: The study demonstrates that supplementing verbal invitations with mobile phone calls and text messages from clinic staff can significantly increase male partner ANC attendance and HIV testing. This combined approach is recommended in improving ANC attendance and HIV testing of male partners who do not accompany their pregnant partners to antenatal clinics in the first visits. TRIAL REGISTRATION: PACTR202209769991162.


Assuntos
Telefone Celular , Infecções por HIV , Teste de HIV , Cuidado Pré-Natal , Parceiros Sexuais , Adulto , Feminino , Humanos , Masculino , Gravidez , Adulto Jovem , Aconselhamento/métodos , Infecções por HIV/diagnóstico , Infecções por HIV/prevenção & controle , Teste de HIV/métodos , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Complicações Infecciosas na Gravidez/diagnóstico , Complicações Infecciosas na Gravidez/prevenção & controle , Cuidado Pré-Natal/métodos , Tanzânia , Envio de Mensagens de Texto
3.
Mikrochim Acta ; 191(3): 123, 2024 02 07.
Artigo em Inglês | MEDLINE | ID: mdl-38324133

RESUMO

A novel electrochemical sensor with a dual-template molecular imprinting technology was fabricated for the simultaneous detection of paracetamol (PAR) and isoniazid (INZ). The sensor was constructed using nitrogen and sulfur co-doped molybdenum carbide (N, S@Mo2C) and a thin layer of electro-polymerized methylene blue was applied onto the surface of the N, S@Mo2C. The electrochemical sensor demonstrated remarkable analytical efficiency for the concurrent PAR and INZ quantification under optimal circumstances. The system achieved an exceptionally low limit of detection (S/N = 3) of  3.7 nM for PAR, with a concentration range  of  0.013 and 140 µM.  A LOD of 7.6 nM was attained for INZ, with a linear range  between 0.025 and 140 µM. Furthermore, the platform's selectivity was evaluated using differential pulse voltammetry  (DPV). The designed platform successfully detected PAR and INZ in authentic samples with recoveries varying between 98.3% and 104.9%. The relative standard deviations (RSD) for these measurements ranged from 2.7 to 4.0%, demonstrating that the proposed sensor is extremely stable, repeatable, and reproducible. These promising results suggest that the sensor holds potential for the detection of various (bio) molecules, paving the way for future applications in sensing fields.


Assuntos
Acetaminofen , Azul de Metileno , Molibdênio , Isoniazida , Nitrogênio , Enxofre
4.
Sensors (Basel) ; 24(6)2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38544131

RESUMO

Unmanned Aerial Vehicles (UAVs) have gained significant popularity in both military and civilian applications due to their cost-effectiveness and flexibility. However, the increased utilization of UAVs raises concerns about the risk of illegal data gathering and potential criminal use. As a result, the accurate detection and identification of intruding UAVs has emerged as a critical research concern. Many algorithms have shown their effectiveness in detecting different objects through different approaches, including radio frequency (RF), computer vision (visual), and sound-based detection. This article proposes a novel approach for detecting and identifying intruding UAVs based on their RF signals by using a hierarchical reinforcement learning technique. We train a UAV agent hierarchically with multiple policies using the REINFORCE algorithm with entropy regularization term to improve the overall accuracy. The research focuses on utilizing extracted features from RF signals to detect intruding UAVs, which contributes to the field of reinforcement learning by investigating a less-explored UAV detection approach. Through extensive evaluation, our findings show the remarkable results of the proposed approach in achieving accurate RF-based detection and identification, with an outstanding detection accuracy of 99.7%. Additionally, our approach demonstrates improved cumulative return performance and reduced loss. The obtained results highlight the effectiveness of the proposed solution in enhancing UAV security and surveillance while advancing the field of UAV detection.

5.
J Med Virol ; 95(1): e27968, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35770346

RESUMO

An outbreak of Monkeypox detected in nonendemic regions outside Africa has received much attention around the globe. In this letter, we highlight epidemiology, pathogenesis, diagnosis, and recommendations to mitigate the spread of monkeypox.


Assuntos
Monkeypox virus , Mpox , Animais , Humanos , Monkeypox virus/genética , Mpox/diagnóstico , Mpox/epidemiologia , Zoonoses/epidemiologia , África/epidemiologia , Surtos de Doenças
6.
Anal Bioanal Chem ; 415(25): 6247-6256, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37667023

RESUMO

An ultrasensitive dual-signal ratiometric electrochemical sensor was developed for creatinine detection utilizing silver nanoparticles (Ag) with intrinsic self-calibration afforded by iron-nickel bimetallic Prussian blue (FeNiPBA) analogues. The Ag@FeNiPBA exhibits two redox signals corresponding to the Ag+/Ag and Fe3+/Fe2+ systems. Adding chloride (Cl-) solution increases the anodic current of the Ag/Ag system significantly due to the formation of silver chloride through solid-state electrochemistry. While the anodic current of the Ag/Ag system decreases in the presence of creatinine due to the competitive reaction, the Fe/Fe system's anodic current remains the same, which enables a ratiometric response. Under optimized conditions, the response ratio (IAg/IFe) decreases while the creatinine concentration increases linearly between 0.015 and 140 µM, with 0.004 µM as a good detection limit (S/N = 3). These results demonstrate superior performance over previously reported methods for electrochemical creatinine determination. The high sensitivity arises from the signal amplification of the Ag/AgCl solid-state electrochemistry, while the selectivity originates from the specific interaction between Ag+ and creatinine. The Ag@FeNiPBA hybrid can quantify creatinine in real samples with good recoveries. This work opens up new opportunities for applying dual-signal nanostructures to develop electrochemical sensors for (bio)molecule detection.

7.
Optom Vis Sci ; 100(10): 688-696, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37639554

RESUMO

SIGNIFICANCE: Clinicians and researchers will have evidence whether intereye differences confound clinical measurements of intraocular pressure or of ocular biomechanical parameters. PURPOSE: The purpose of this study was to determine whether intraocular pressure and biomechanical parameters, as measured by the Ocular Response Analyzer (ORA) and by Cornea Visualization with Scheimpflug Technology (CorVis ST), are different between the first and second eye measured. METHODS: Intraocular pressure and biomechanical parameters were collected from both eyes of healthy participants (N = 139). The ORA measured corneal-compensated intraocular pressure, Goldmann-correlated intraocular pressure, and corneal hysteresis. The CorVis ST measured biomechanically corrected intraocular pressure, stiffness parameter at first applanation, and stiffness parameter at highest concavity. For each measurement, a paired t test compared the value of the first eye measured against that of the second eye measured. RESULTS: For the ORA, Goldmann-correlated intraocular pressure was significantly higher ( P = .001) in the first eye (14.8 [3.45] mmHg) than in the second eye (14.3 [3.63] mmHg). For the CorVis ST, biomechanically corrected intraocular pressure was significantly higher ( P < .001) in the second eye (14.7 [2.14] mmHg) than in the first eye (14.3 [2.11] mmHg). Stiffness parameter at first applanation (intereye difference, 6.85 [9.54] mmHg/mm) was significantly ( P < .001) higher in the first eye than in the second eye. Stiffness parameter at highest concavity was significantly higher ( P = .01) in the second eye (14.3 [3.18] mmHg/mm) than in the first eye (14.0 [3.13] mmHg/mm). CONCLUSIONS: Although there were statistically significant intereye differences in intraocular pressure and in biomechanical parameters for both devices, the variations were small and thus unlikely to affect clinical outcomes.


Assuntos
Oftalmopatias , Pressão Intraocular , Humanos , Fenômenos Biomecânicos , Tonometria Ocular , Córnea/fisiologia
8.
Mikrochim Acta ; 191(1): 25, 2023 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-38091119

RESUMO

A new nanocomposite consisting of lanthanum ferrite nanoparticles (LaFeO3 NPs) integrated with carbon nanotubes (CNTs) was fabricated via facile sonochemical approach. The engineered nanocomposite was applied to simultaneously determine acetaminophen (ACP) and dopamine (DA) in a binary mixture. The LaFeO3 NPs@CNT probe possesses several advantages such as superior conductivity, large surface area, and more active sites, improving its electrocatalytic activity towards ACP and DA. Under optimized conditions, the anodic peak currents (Ipa) linearly increased with increasing concentration of ACP and DA in the range 0.069-210 µM and 0.15-210 µM, respectively. The sensitivity of LaFeO3 NPs@CNTs/glassy carbon electrode (GCE) for detecting ACP and DA is 7.456 and 5.980 µA·µM-1·cm-2, respectively. The detection limits (S/N = 3) for ACP and DA are 0.02 µM and 0.05 µM, respectively. Advantages of LaFeO3 NPs@CNTs/GCE for the detection of ACP and DA include wide linear ranges, low-detection limits, good selectivity, and long-term stability. The as-fabricated electrode was applied to determine ACP and DA in pharmaceutical formulations and human serum samples with recoveries ranging from 97.7 to 103.3% and an RSD that did not exceed 3.7%, confirming the suitability of the proposed sensor for the determination of ACP and DA in real samples. This study not only presents promising opportunities for enhancing the sensitivity and stability of electrochemical sensors used in the detection of bioanalytes but also significantly contributes to the progress of unique and comprehensive biochemical detection methodologies.


Assuntos
Nanopartículas , Nanotubos de Carbono , Humanos , Nanotubos de Carbono/química , Dopamina , Acetaminofen , Lantânio
9.
Mikrochim Acta ; 190(12): 467, 2023 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-37955722

RESUMO

A ratiometric-based fluorescence emission system was proposed for the determination of sulfide. It consists of blue emissive graphene quantum dots (GQDs) and self-assembled thiolate-protected gold nanoclusters driven by aluminum ion (Al3+@GSH-AuNCs). The two types of fluorophores are combined to form a ratiometric emission probe. The orange emission of Al3+ @GSH-AuNCs at 624 nm was quenched in the presence of sulfide ion owing to the strong affinity between sulfide and Au(I), while the blue GQDs fluorescence at 470 nm remained unaffected. Interestingly, the Al3+@GSH-AuNCs and GQDs were excited under the same excitation wavelength (335 nm). The response ratios (F470/F624) are linearly proportional to the sulfide concentration within the linear range of 0.02-200 µM under the optimal settings, with a limit of detection (S/N = 3) of 0.0064 µM. The proposed emission probe was applied to detect sulfide ions in tap water and wastewater specimens, with recoveries ranging from 95.3% to 103.3% and RSD% ranging from 2.3% to 3.4%, supporting the proposed method's accuracy.

10.
Int J Health Plann Manage ; 38(2): 317-329, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36457176

RESUMO

Typhoid fever, a classical disease of enteric origin caused by Salmonella species of bacteria, is among the most important diseases threatening public health in Africa. The African continent is a marker for both low resources within the healthcare system and poor disease control policy formulations in managing endemic infectious diseases. Since the colonial era, the Widal serological test has been used to confirm typhoid fever in Africa, however recent studies recommend blood culture, and when blood culture cannot be obtained, clinical findings, laboratory Widal test confirmation, and ruling out other febrile illnesses as confirmatory pathway to diagnose typhoid fever in Africa. Managing typhoid fever relies on antimicrobials. In 1980s chloramphenicol was the medication of choice. Years later, amoxicillin and co-trimoxazole were adopted. However, the instantaneous rise of resistant strains of Salmonella enterica confers an important challenge to treat the burdensome enteric fever. The current treatment algorithm of typhoid fever in Africa relies significantly on the use of fluoroquinolones, macrolides, and cephalosporins. Developed nations have successfully addressed and controlled typhoid fever via improvement in accessing safe water and food, better sanitary and hygienic behaviours, and vaccines development. Nevertheless, there is significant evidence to infer improvement in the diagnosis management of typhoid fever over the last few decades, and efforts are underway to control the disease spread in Africa. This review aims to provide an overview of the latest developments in typhoid fever diagnosis and management in Africa and provide key recommendations for a coordinated approach to mitigate typhoid in the continent.


Assuntos
Febre Tifoide , Humanos , Febre Tifoide/diagnóstico , Febre Tifoide/epidemiologia , Febre Tifoide/microbiologia , Antibacterianos/uso terapêutico , África/epidemiologia , Cefalosporinas/uso terapêutico , Amoxicilina/uso terapêutico
11.
Anal Bioanal Chem ; 414(7): 2343-2353, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34984506

RESUMO

A gold nanoparticle-modified copper-based metal organic framework (Au NPs@Cu-BDC) was fabricated for the electrochemical determination of cysteine (Cys-SH). The nanocomposites were characterized using different techniques such as scanning electron microscopy (SEM), transmission electron microscopy (TEM), energy-dispersive X-ray spectroscopy (EDX), powder X-ray spectroscopy (PXRD), thermogravimetry (TGA), nitrogen adsorption-desorption isotherms, and Fourier transform infrared spectroscopy (FTIR). Formation of a new anodic peak of Cu(II)-Cys complex at + 0.43 V was used to detect Cys-SH. Cyclic and square wave voltammetric studies proved that the Au NPs enhanced the conductivity of Cu-BDC. The proposed electrode exhibited a linear range of 0.0015-10.5 µM and low detection limit of 0.0004 µM with a good sensitivity of 0.78 ± 0.01 µA µM. The as-fabricated electrode was successfully used for the estimation of Cys-SH in real samples (human plasma, urine, and saliva) with recovery % of 99-100% and RSD % of 2.7-3.6%, respectively.


Assuntos
Nanopartículas Metálicas , Estruturas Metalorgânicas , Cobre/química , Cisteína , Técnicas Eletroquímicas/métodos , Eletrodos , Ouro/química , Humanos , Limite de Detecção , Nanopartículas Metálicas/química , Estruturas Metalorgânicas/química
12.
Postgrad Med J ; 98(1162): 569-571, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35654572

RESUMO

The conflict between Ukraine and Russia significantly influences the healthcare sector. The ongoing COVID-19 pandemic and the armed conflict have badly devastated the established healthcare system. Only 36.08% of the Ukrainian population has received the COVID-19 vaccination, with the majority receiving two doses, and currently, Ukraine records the highest mortality rate in the world. In addition to the conflict injuries, increased susceptible deaths to COVID-19 can be found due to inadequate vaccination rates for the disease. To save their lives and for their well-being, many individuals have been relocating to the underground metro stations, other cities, nearby towns and countries. In these settings, social distancing, hand sanitation and wearing masks are not prioritised. In the current circumstances, the broken healthcare system needs to be rebuilt, and the Non-Governmental Organizations (NGOs), doctors and all the front-line workers should extend their humanitarian support to the Ukrainian population. Conclusion: It is an arduous task for healthcare organisations to supply vaccines and medicines in this 'armed conflict' between Russia and Ukraine. This can only happen when both parties extend their support to rebuild the shattered healthcare infrastructure.


Assuntos
COVID-19 , COVID-19/epidemiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Atenção à Saúde , Humanos , Pandemias/prevenção & controle , Ucrânia/epidemiologia
13.
Eye Contact Lens ; 48(11): 466-470, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36083177

RESUMO

OBJECTIVES: To assess scleral lens fluid reservoir (FR) change simultaneously in four quadrants with single acquisition using novel ANTERION anterior segment swept-source optical coherence tomography (SS-OCT). METHODS: A prospective, observational, clinical study of 18 subjects (30 eyes) was performed on adults fitted with a scleral lens for ocular surface disease (n=8), irregular cornea/scar (n=7), and corneal ectasia (n=15). ANTERION anterior segment SS-OCT imaging was obtained at the initial visit and at the follow-up to determine pre and post scleral lens settling, measured in microns, centrally and peripherally. Peripheral measurements were grouped into four quadrants. Repeated-measures ANOVA was performed comparing vault post minus pre differences by quadrant, and TTests comparing difference in FR by lens design were performed with a significant threshold at P <0.05. RESULTS: The mean central scleral lens settling was significant at -48.3±41.7 µm. The change in FR by quadrant was superior (S): -47.8±67.3 µm, inferior (I): -68.0±102.2 µm, nasal (N) -46.3±63.4 µm, and temporal (T): -56.7±49.3 µm. There were no significant differences in lens settling between the quadrants. Within the three categories, the irregular cornea group experienced significantly greater lens settling. There was no significant difference in central FR when comparing lens design or lens diameter. CONCLUSIONS: The ANTERION SS-OCT allows for high-resolution central and peripheral assessment of FR in scleral lens wear. With increased technology available for scleral lens customization, this imaging modality can assist in more detailed assessment in quadrant-specific scleral lens designs.


Assuntos
Lentes de Contato , Tomografia de Coerência Óptica , Adulto , Humanos , Tomografia de Coerência Óptica/métodos , Estudos Prospectivos , Esclera/diagnóstico por imagem , Córnea/diagnóstico por imagem
14.
Mikrochim Acta ; 189(5): 183, 2022 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-35394214

RESUMO

An one-pot hydrothermal method was developed for synthesis of carbon quantum dots co-doped with copper and nitrogen (Cu, N@CQDs). The synthesized Cu, N@CQDs has unique advantages such as high fluorescence quantum yield (39.1%) and high catalytic activity. Oxidative coupling of amoxicillin (AMX) with 4-aminoantipyrine (4-NH2-APE) in the presence of H2O2 as an oxidant to produce pink quinoneimine chromogen was carried out with the aid of Cu, N@CQDs as a peroxidase-like catalyst. This system was used for the colorimetric and fluorometric assays of AMX with reliable results. Colorimetric method is based on the measurement of a pink-colored product at λmax = 505 nm while the fluorometric assay is based on the quenching of the fluorescence emission of Cu, N@CQDs at 440 nm after excitation at 370 nm. For the colorimetric method, the absorption intensity linearly increased over the concentration range 4.3-110.0 µM with LOD (S/N = 3) of 1.3 µM. For the fluorometric method, the emission intensity of Cu, N@CQDs linearly decreased upon addition of AMX in the concentration range 0.2-120.0 µM with a limit of detection (LOD, S/N = 3) of 0.06 µM. The proposed system was applied to the determination of AMX in different real samples such as pharmaceutical capsules, human serum, milk, and conduit water samples with recoveries in the range 95.8-104.1% and relative standard deviation (RSD %) less than 4.1%.


Assuntos
Pontos Quânticos , Amoxicilina , Ampirona , Carbono , Cobre , Humanos , Peróxido de Hidrogênio , Nitrogênio
15.
Sensors (Basel) ; 22(5)2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35271067

RESUMO

Unmanned Aerial Vehicles (UAVs) are considered an important element in wireless communication networks due to their agility, mobility, and ability to be deployed as mobile base stations (BSs) in the network to improve the communication quality and coverage area. UAVs can be used to provide communication services for ground users in different scenarios, such as transportation systems, disaster situations, emergency cases, and surveillance. However, covering a specific area under a dynamic environment for a long time using UAV technology is quite challenging due to its limited energy resources, short communication range, and flying regulations and rules. Hence, a distributed solution is needed to overcome these limitations and to handle the interactions among UAVs, which leads to a large state space. In this paper, we introduced a novel distributed control solution to place a group of UAVs in the candidate area in order to improve the coverage score with minimum energy consumption and a high fairness value. The new algorithm is called the state-based game with actor-critic (SBG-AC). To simplify the complex interactions in the problem, we model SBG-AC using a state-based potential game. Then, we merge SBG-AC with an actor-critic algorithm to assure the convergence of the model, to control each UAV in a distributed way, and to have learning capabilities in case of dynamic environments. Simulation results show that the SBG-AC outperforms the distributed DRL and the DRL-EC3 in terms of fairness, coverage score, and energy consumption.

16.
Sensors (Basel) ; 22(22)2022 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-36433263

RESUMO

Medium access control (MAC) protocols in ad hoc networks have evolved from single-channel independent transmission mechanisms to multi-channel concurrent mechanisms to efficiently manage the demands placed on modern networks. The primary aim of this study is to compare the performance of popular multi-channel MAC (MMAC) protocols under saturated network traffic conditions and propose improvements to the protocols under these conditions. A novel, dynamically adaptive MMAC protocol was devised to take advantage of the performance capabilities of the evaluated protocols in changing wireless ad hoc network conditions. A simulation of the familiar MAC protocols was developed based on a validated simulation of the IEEE 802.11 standard. Further, the behaviors and performances of these protocols are compared against the proposed MMAC protocols with a varying number of ad hoc stations and concurrent wireless channels in terms of throughput, Jain's fairness index, and channel access delay. The results show that the proposed MMAC protocol, labeled E-SA-MMAC, outperforms the existing protocols in throughput by up to 11.9% under a constrained number of channels and in channel access delays by up to 18.3%. It can be asserted from these observations that the proposed approach provides performance benefits against its peers under saturated traffic conditions and other factors, such as the number of available wireless channels, and is suitable for dynamic ad hoc network deployments.

17.
Exp Eye Res ; 206: 108542, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33744258

RESUMO

The aim of the study was to investigate the effectiveness of exogenous recombinant human decoron and an accompanying penetration-enhancing solution in stiffening ex-vivo porcine corneas both transepithelially and after de-epithelialization. Eight porcine paired eyes were treated transepithelially: one eye with a pre-treatment solution (Pre-Tx), penetration enhancing solution (PE), and decoron while the fellow eye was treated by the same protocol but without decoron. A second group included 4 de-epithelialized pairs treated identically. The final group included 4 de-epithelialized pairs with one eye treated with Pre-Tx, PE, and decoron while the fellow eye was treated without PE. Uniaxial tensile testing was used to compare the corneal stiffness between the different treatment conditions. Residual tissue underwent immunohistochemistry analysis to evaluate the depth of penetration of decoron into the corneal stroma. There was no stiffening effect exhibited among corneas treated transepithelially with decoron compared to control (P > 0.05) and poor stromal penetration was exhibited on tissue analysis. Among de-epithelialized corneas, there was a significant stiffening effect seen in those treated with decoron at 3%, 4%, 5%, & 6% strain (P < 0.05) compared to control. Among de-epithelialized corneas there was also a significant stiffening effect seen in those treated with the PE and decoron at 4%, 5%, & 6% strain (P < 0.05) with improved stromal penetration confirmed by immunohistochemistry, versus without PE. De-epithelialization is necessary for effective stromal penetration of decoron. Depth of penetration and subsequent corneal stiffening may be improved with a penetration enhancing solution. Compared to riboflavin, decoron requires shorter treatment time and spares UV light exposure.


Assuntos
Colágeno/farmacologia , Substância Própria/efeitos dos fármacos , Reagentes de Ligações Cruzadas/farmacologia , Ceratocone/tratamento farmacológico , Riboflavina/farmacologia , Animais , Substância Própria/patologia , Substância Própria/fisiopatologia , Modelos Animais de Doenças , Elasticidade , Epitélio Corneano/efeitos dos fármacos , Epitélio Corneano/patologia , Epitélio Corneano/fisiopatologia , Ceratocone/patologia , Ceratocone/fisiopatologia , Fármacos Fotossensibilizantes/farmacologia , Suínos , Raios Ultravioleta
18.
J Biochem Mol Toxicol ; 35(2): e22637, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32997381

RESUMO

Limited information has been offered regarding the association of mesothelin (MSLN) gene variants at the 3'-untranslated region with the risk of ovarian carcinoma. The primary objective of this work is to assess the impact of the MSLN (rs1057147 and rs57272256) variants on the progression of ovarian carcinoma among Egyptian women. The study was conceived based on 127 women diagnosed with ovarian carcinoma and 106 unrelated cancer-free controls. Genomic DNA of these MSLN variants was genotyped utilizing the PCR technique. The frequencies of the MSLN (rs1057147) variant revealed a significant association with increased risk of ovarian carcinoma under allelic and dominant models (P < .05). Nonetheless, ovarian cancer patients with the MSLN (rs57272256) variant did not attain considerable significance under all genetic models (P > .05). Together, our findings suggested that the MSLN (rs1057147) variant was associated with an increased risk of ovarian carcinoma, but not the MSLN (rs57272256) variant.


Assuntos
Regiões 3' não Traduzidas , Proteínas Ligadas por GPI/genética , Neoplasias Ovarianas/genética , Polimorfismo Genético , Estudos de Casos e Controles , Egito , Feminino , Predisposição Genética para Doença , Estudo de Associação Genômica Ampla , Humanos , Mesotelina , Pessoa de Meia-Idade , Análise Multivariada , Análise de Componente Principal
19.
Microchem J ; 163: 105925, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33437097

RESUMO

In this research paper, an innovative electrochemical sensor was suggested for simultaneous voltammetric analysis of azithromycin (AZM) and hydroxychloroquine (HCQ) for the first time. The sensor based on hydrothermal synthesis of vanadium disulfide quantum dots (VS2 QDs) and insertion within 3D N, S graphene aerogel (3D N, S @ GNA) and carbon nanotubes nanaostructure as a new and widely group of carbon nanomaterials. The nanocomposites were characterized morphologically using different techniques. In addition, the nanomaterials were characterized electrochemically using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV). The proposed electrochemical sensor showed wide dynamic linear ranges of 0.28-30 × 10-8 M and 0.84-22.5 × 10-8 M for analysis of AZM and HCQ, respectively. The limits of detection (LODs) based on signal to noise (S/N) 3:1 were found to be 0.091 × 10-8 M and 0.277 × 10-8 M for AZM and HCQ, respectively. Briefly, the electrochemical sensor had good stability, selectivity, reproducibility and feasibility for simultaneous detection of AZM and HCQ in presence of different interfering species.

20.
Microchem J ; 164: 105972, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33518809

RESUMO

In this study, zinc sulfide nanoparticles were loaded on reduced graphene oxide (ZnS NPs/rGO) using simple sonochemical method. The nanocomposite was characterized using different morphological and electrochemical techniques such as TEM, SEM, PXRD, EDX, Raman spectroscopy, FTIR, N2-adsorption-desorption, CV, and EIS. The ZnS NPs/rGO modified glassy carbon electrode (GCE) was used to simultaneously estimate hydroxychloroquine (HCQ) and daclatasvir (DAC) in a binary mixture for the first time. The modified nanocomposite exhibited good catalytic activity towards HCQ and DAC detection. In addition, it showed higher sensitivity, good selectivity and stability; and high reproducibility towards HCQ and DAC analysis. The activity of the modified electrode was noticeably improved due to synergism between ZnS NPs and rGO. Under optimum conditions of DPV measurements, the anodic peak currents (Ipa) were obviously increased with the increase of HCQ and DAC amounts with linear ranges of 5.0-65.0 and 7.0-65.0 nM with LODs of 0.456 and 0.498 nM for HCQ and DAC, respectively. The ZnS NPs/ rGO modified GCE was used to quantify HCQ and DAC in biological fluids with recoveries of 98.7-102.7% and 96.9-104.5% and RSDs of 1.89-3.57% and 1.91-3.70%, respectively.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA