Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
2.
Klin Monbl Augenheilkd ; 235(4): 404-408, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29669367

RESUMO

PURPOSE: To report the visual outcomes and complications of automated anterior lamellar therapeutic keratoplasty (ALTK) in adults and children, and to examine these outcomes as a function of age and etiology. METHODS: A consecutive series of cases undergoing automated ALTK procedures performed at the Jules-Gonin Eye Hospital Lausanne, Switzerland, between June 2003 and January 2015. Only patients with at least 3 months of follow-up were included. RESULTS: There were 53 eyes (24 right) of 51 patients (17 female, 16 juvenile), with a mean age of 34.8 years (range from 3 months to 88 years), analyzed. The mean follow-up was 35 (± 26) months. Diagnosis in the adult (n = 37) vs. juvenile (n = 16) eyes was different: opacity following surgical complication 8 vs. 0, congenital 1 vs. 1, dystrophy 5 vs. 2, infection 12 vs. 5, keratectasia 3 vs. 0, trauma 7 vs. 0, tumor 1 vs. 3, and allergy 0 vs. 5. Visual impairment as a consequence of corneal scarring was the principle indication for surgery in both adult (70%; 26) and juvenile eyes (63%; 10); other indications were choristoma, dermoid, other tumors, astigmatism, and congenital opacity. In adult vs. juvenile eyes, the mean visual acuity (spectacle and contact lenses) was, at last visit, 0.55 vs. 0.45 LogMAR (p = 0.78), with a range of 100% to hand movements. Failure occurred in 6 (16%) vs. 2 (13%) cases and complications were observed in 14 (38%) vs. 9 (56%) cases, however, more surgical revision was required in juvenile eyes, 4 (11%) vs. 7 (43%) (p = 0.01, Fisher test). CONCLUSIONS: This study shows that anterior lamellar keratoplasty in children retains good visual function when combined with adequate amblyopic therapy. However, the rate of complications is higher in juveniles and requires more intensive interdisciplinary follow-up.


Assuntos
Opacidade da Córnea/cirurgia , Substância Própria/cirurgia , Transplante de Córnea/instrumentação , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Astigmatismo/etiologia , Criança , Pré-Escolar , Transplante de Córnea/métodos , Feminino , Seguimentos , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Refração Ocular , Estudos Retrospectivos , Acuidade Visual , Adulto Jovem
3.
PLoS Comput Biol ; 11(3): e1004050, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25768678

RESUMO

Angiogenesis plays a key role in tumor growth and cancer progression. TIE-2-expressing monocytes (TEM) have been reported to critically account for tumor vascularization and growth in mouse tumor experimental models, but the molecular basis of their pro-angiogenic activity are largely unknown. Moreover, differences in the pro-angiogenic activity between blood circulating and tumor infiltrated TEM in human patients has not been established to date, hindering the identification of specific targets for therapeutic intervention. In this work, we investigated these differences and the phenotypic reversal of breast tumor pro-angiogenic TEM to a weak pro-angiogenic phenotype by combining Boolean modelling and experimental approaches. Firstly, we show that in breast cancer patients the pro-angiogenic activity of TEM increased drastically from blood to tumor, suggesting that the tumor microenvironment shapes the highly pro-angiogenic phenotype of TEM. Secondly, we predicted in silico all minimal perturbations transitioning the highly pro-angiogenic phenotype of tumor TEM to the weak pro-angiogenic phenotype of blood TEM and vice versa. In silico predicted perturbations were validated experimentally using patient TEM. In addition, gene expression profiling of TEM transitioned to a weak pro-angiogenic phenotype confirmed that TEM are plastic cells and can be reverted to immunological potent monocytes. Finally, the relapse-free survival analysis showed a statistically significant difference between patients with tumors with high and low expression values for genes encoding transitioning proteins detected in silico and validated on patient TEM. In conclusion, the inferred TEM regulatory network accurately captured experimental TEM behavior and highlighted crosstalk between specific angiogenic and inflammatory signaling pathways of outstanding importance to control their pro-angiogenic activity. Results showed the successful in vitro reversion of such an activity by perturbation of in silico predicted target genes in tumor derived TEM, and indicated that targeting tumor TEM plasticity may constitute a novel valid therapeutic strategy in breast cancer.


Assuntos
Neoplasias da Mama/fisiopatologia , Modelos Biológicos , Monócitos/fisiologia , Neovascularização Patológica/fisiopatologia , Animais , Neoplasias da Mama/metabolismo , Neoplasias da Mama/mortalidade , Linhagem Celular , Biologia Computacional , Citocinas/metabolismo , Citocinas/fisiologia , Feminino , Humanos , Estimativa de Kaplan-Meier , Camundongos , Camundongos Transgênicos , Pessoa de Meia-Idade , Monócitos/química , Monócitos/classificação , Neoplasias Experimentais , Fenótipo , Transdução de Sinais/fisiologia
4.
Ophthalmology ; 121(9): 1683-92, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24811963

RESUMO

OBJECTIVE: Eye drops of aganirsen, an antisense oligonucleotide preventing insulin receptor substrate-1 expression, inhibited corneal neovascularization in a previous dose-finding phase II study. We aimed to confirm these results in a phase III study and investigated a potential clinical benefit on visual acuity (VA), quality of life (QoL), and need for transplantation. DESIGN: Multicenter, double-masked, randomized, placebo-controlled phase III study. PARTICIPANTS: Analysis of 69 patients with keratitis-related progressive corneal neovascularization randomized to aganirsen (34 patients) or placebo (35 patients). Patients applied aganirsen eye drops (86 µg/day/eye) or placebo twice daily for 90 days and were followed up to day 180. MAIN OUTCOME MEASURES: The primary end point was VA. Secondary end points included area of pathologic corneal neovascularization, need for transplantation, risk of graft rejection, and QoL. RESULTS: Although no significant differences in VA scores between groups were observed, aganirsen significantly reduced the relative corneal neovascularization area after 90 days by 26.20% (P = 0.014). This improvement persisted after 180 days (26.67%, P = 0.012). Aganirsen tended to lower the transplantation need in the intent-to-treat (ITT) population at day 180 (P = 0.087). In patients with viral keratitis and central neovascularization, a significant reduction in transplantation need was achieved (P = 0.048). No significant differences between groups were observed in the risk of graft rejection. However, aganirsen tended to decrease this risk in patients with traumatic/viral keratitis (P = 0.162) at day 90. The QoL analyses revealed a significant improvement with aganirsen in composite and near activity subscores (P = 0.039 and 0.026, respectively) at day 90 in the per protocol population. Ocular and treatment-related treatment-emergent adverse events (TEAEs) were reported in a lower percentage with aganirsen compared with placebo. Only 3 serious TEAEs (2 with aganirsen and 1 with placebo) were considered treatment-related. CONCLUSIONS: This first phase III study on a topical inhibitor of corneal angiogenesis showed that aganirsen eye drops significantly inhibited corneal neovascularization in patients with keratitis. The need for transplantation was significantly reduced in patients with viral keratitis and central neovascularization. Topical application of aganirsen was safe and well tolerated.


Assuntos
Inibidores da Angiogênese/uso terapêutico , Neovascularização da Córnea/tratamento farmacológico , Transplante de Córnea , Ceratite/complicações , Oligonucleotídeos Antissenso/uso terapêutico , Oligonucleotídeos/uso terapêutico , Adulto , Idoso , Análise de Variância , Neovascularização da Córnea/etiologia , Neovascularização da Córnea/cirurgia , Método Duplo-Cego , Feminino , Rejeição de Enxerto , Humanos , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas , Qualidade de Vida , Acuidade Visual/efeitos dos fármacos
5.
Nature ; 456(7219): 250-4, 2008 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-18830243

RESUMO

The integrity of the cornea, the most anterior part of the eye, is indispensable for vision. Forty-five million individuals worldwide are bilaterally blind and another 135 million have severely impaired vision in both eyes because of loss of corneal transparency; treatments range from local medications to corneal transplants, and more recently to stem cell therapy. The corneal epithelium is a squamous epithelium that is constantly renewing, with a vertical turnover of 7 to 14 days in many mammals. Identification of slow cycling cells (label-retaining cells) in the limbus of the mouse has led to the notion that the limbus is the niche for the stem cells responsible for the long-term renewal of the cornea; hence, the corneal epithelium is supposedly renewed by cells generated at and migrating from the limbus, in marked opposition to other squamous epithelia in which each resident stem cell has in charge a limited area of epithelium. Here we show that the corneal epithelium of the mouse can be serially transplanted, is self-maintained and contains oligopotent stem cells with the capacity to generate goblet cells if provided with a conjunctival environment. Furthermore, the entire ocular surface of the pig, including the cornea, contains oligopotent stem cells (holoclones) with the capacity to generate individual colonies of corneal and conjunctival cells. Therefore, the limbus is not the only niche for corneal stem cells and corneal renewal is not different from other squamous epithelia. We propose a model that unifies our observations with the literature and explains why the limbal region is enriched in stem cells.


Assuntos
Células-Tronco Adultas/citologia , Epitélio Corneano/citologia , Células-Tronco Multipotentes/citologia , Animais , Bovinos , Células Cultivadas , Pré-Escolar , Células Clonais , Transplante de Córnea , Epitélio Corneano/metabolismo , Feminino , Regulação da Expressão Gênica , Humanos , Lactente , Queratinócitos/citologia , Queratinócitos/metabolismo , Masculino , Camundongos , Camundongos SCID , Modelos Biológicos , Proteínas/metabolismo , Ratos , Suínos
6.
Dev Cell ; 13(2): 242-53, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17681135

RESUMO

Integrity and preservation of a transparent cornea are essential for good vision. The corneal epithelium is stratified and nonkeratinized and is maintained and repaired by corneal stem cells. Here we demonstrate that Notch1 signaling is essential for cell fate maintenance of corneal epithelium during repair. Inducible ablation of Notch1 in the cornea combined with mechanical wounding show that Notch1-deficient corneal progenitor cells differentiate into a hyperplastic, keratinized, skin-like epithelium. This cell fate switch leads to corneal blindness and involves cell nonautonomous processes, characterized by secretion of fibroblast growth factor-2 (FGF-2) through Notch1(-/-) epithelium followed by vascularization and remodeling of the underlying stroma. Vitamin A deficiency is known to induce a similar corneal defect in humans (severe xerophthalmia). Accordingly, we found that Notch1 signaling is linked to vitamin A metabolism by regulating the expression of cellular retinol binding protein 1 (CRBP1), required to generate a pool of intracellular retinol.


Assuntos
Linhagem da Célula , Epitélio Corneano/citologia , Receptor Notch1/metabolismo , Transdução de Sinais , Vitamina A/metabolismo , Cicatrização , Animais , Diferenciação Celular , Movimento Celular , Substância Própria/patologia , Células Epidérmicas , Epitélio Corneano/patologia , Queratinas/metabolismo , Glândulas Tarsais/anormalidades , Camundongos , Modelos Biológicos , Receptor Notch1/deficiência , Proteínas de Ligação ao Retinol/metabolismo , Proteínas Celulares de Ligação ao Retinol , Células-Tronco/citologia
8.
J Refract Surg ; 26(10): 762-5, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20481415

RESUMO

PURPOSE: To report the effect of corneal collagen cross-linking (CXL) with riboflavin and ultraviolet A (UVA) on the optical and material characteristics of a posterior chamber phakic intraocular lens (Visian ICL, STAAR Surgical). METHODS: Optical and material characteristics were assessed in vitro, analyzing potential changes in riboflavin staining, dioptric power, transmission characteristics, and surface structure. A total of 9 lenses were analyzed: 3 lenses were irradiated with 0.23 mW/cm², the maximal intensity that may be encountered during actual surgery; 3 lenses were irradiated with 2.3 mW/cm², 10 times the maximal intensity encountered during surgery; and 3 lenses served as controls. RESULTS: Following CXL with UVA and riboflavin, no changes were observed in the parameters tested; in particular, dioptric power and transmission characteristics were similar before and after CXL. CONCLUSIONS: Cross-linking with UVA and riboflavin does not affect the optical and material characteristics of the Visian ICL after irradiation with the maximal UVA energy levels that may be encountered during surgery. Even when the UVA irradiation dose was increased by a factor of 10, no changes were observed.


Assuntos
Óptica e Fotônica , Lentes Intraoculares Fácicas , Fármacos Fotossensibilizantes/farmacologia , Riboflavina/farmacologia , Raios Ultravioleta , Microscopia Eletrônica
9.
Eye Vis (Lond) ; 4: 24, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29124079

RESUMO

BACKGROUND: Reaching a consensus on which parameters are most reliable at detecting progressive keratoconus patients with serial topography imaging is not evident. The aim of the study was to isolate the parameters best positioned to detect keratoconus progression using the Pentacam HR® measures based on the respective limits of repeatability and range of measurement. METHOD: Using the Pentacam HR®, a tolerance index was calculated on anterior segment parameters in healthy and keratoconic eyes. The tolerance index provides a scale from least to most affected parameters in terms of measurement noise relative to that observed in healthy eyes. Then, based on the "number of increments" from no disease to advanced disease, a relative utility (RU) score was also calculated. RU values close to 1 indicate parameters best positioned to detect a change in keratoconic eyes. RESULTS: The tolerance index values indicated that 36% of ocular parameters for keratoconic eyes had repeatability limits which were wider than normative limits (worse), but 28% of the ocular parameters were narrower than normative limits (better). Considering only those parameters with a RU greater than 0.95, a small number of parameters were within this range, such as corneal curvature and asphericity indices. CONCLUSIONS: This study demonstrates that measurement error in keratoconic eyes is significantly greater than healthy eyes. Indices implemented here provide guidance on the levels of expected precision in keratoconic eyes relative to healthy eyes to aid clinicians in distinguishing real change from noise. Importantly maximal keratometry (Kmax), central corneal thickness (CCT) and thinnest corneal thickness (TCT) were highlighted as problematic indices for the follow-up of keratoconus in terms of repeatability.

10.
J Cataract Refract Surg ; 43(6): 748-753, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28732607

RESUMO

PURPOSE: To assess safety, efficacy, and predictability of combined Implantable Collamer Lens phakic intraocular lens (pIOL) explantation and phacoemulsification and to report the rate of complications. A secondary aim was to examine whether intraocular lens (IOL) power calculation was affected by the pIOL in situ. SETTING: Jules-Gonin Eye Hospital, Lausanne, Switzerland. DESIGN: Retrospective case series. METHODS: The records of patients having pIOL implantation with subsequent phacoemulsification were reviewed. Data analysis was performed between July 1, 2015, and December 31, 2015. The mean corrected distance visual acuity (CDVA), safety, stability of refraction, predictability of IOL power calculation, and postoperative complications were recorded. RESULTS: The study comprised 38 eyes (29 patients). Of the eyes, 32 (82%) were within ±1.00 diopter (D) of the target refraction and 21 (57.9%) were within ±0.50 D. The mean CDVA after IOL implantation was significantly better than before pIOL implantation (P < .001) and similar to after pIOL implantation (P = .87). The safety of this multistepped procedure was good; on average, 1.6 Snellen lines of CDVA were gained over before pIOL implantation. Branch retinal vein occlusion occurred in 1 eye; no other sight-threatening complications were observed. Posterior capsule opacification developed in 15 eyes (39.5%) and was treated successfully with neodymium:YAG capsulotomy. CONCLUSIONS: The highest mean CDVA was recorded at the final visit. Good safety, stability, and predictability were also observed. Postoperative complications were few and in all but 1 case, not sight threatening. Overall, results indicate the combination of procedures does not negatively affect the final visual outcome.


Assuntos
Extração de Catarata , Implante de Lente Intraocular , Facoemulsificação , Lentes Intraoculares Fácicas , Remoção de Dispositivo , Humanos , Implante de Lente Intraocular/métodos , Polímeros , Complicações Pós-Operatórias , Estudos Retrospectivos , Acuidade Visual
11.
Am J Ophthalmol ; 161: 116-25.e1, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26454242

RESUMO

PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN: Interinstrument reliability and bias assessment study. METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.


Assuntos
Biometria/métodos , Implante de Lente Intraocular , Limbo da Córnea/anatomia & histologia , Miopia Degenerativa/cirurgia , Nomogramas , Lentes Intraoculares Fácicas , Esclera/anatomia & histologia , Viés , Topografia da Córnea , Humanos , Microscopia Acústica , Reprodutibilidade dos Testes
12.
Curr Eye Res ; 41(10): 1302-1309, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26881295

RESUMO

PURPOSE: To compare the stromal bed surface quality and the accuracy of dissection depth after deep lamellar cuts using the Leonardo Da Vinci (LDV) femtosecond laser (Z6) and the ONE Microkeratome. METHODS: Deep lamellar cuts were performed on nine human donor corneoscleral buttons: five with the LDV femtosecond (FS) laser (Z6) (Ziemer) and four with the ONE Microkeratome (MK) (Moria). Corneal thickness was measured with ultrasound pachymetry before and after the dissection. The Stromal bed quality was evaluated using light microscopy (n = 4) and scanning electron microscopy (SEM) (n = 9). The surface roughness on SEM images was graded on the scale of 1 (smoothest) to 5 (roughest) by four observers, blinded to the method used. Particle analysis on the SEM images was performed in order to have an objective measure of smoothness. RESULTS: The achieved dissection depth using the FS laser was 496.4 ± 46.4 µm when attempting 500 µm and 474 ± 60 µm with the microkeratome when attempting 350 µm. Histological evaluation of the corneoscleral buttons by both light and electron microscopy showed significantly smoother surface using the FS laser compared to the microkeratome. There were fewer and smaller particles observed in the SEM images of FS laser cut buttons (p < 0.001).The average observer based score of anterior surface roughness (50×) was 2.2 for the FS laser and 3.9 for the microkeratome dissections (p < 0.001). CONCLUSIONS: The LDV femtosecond laser (Z6) platform is capable of creating deep corneal lamellar dissection with smoother surface quality and with more predictable cut depth as compared to the One Microkeratome.


Assuntos
Doenças da Córnea/cirurgia , Substância Própria/ultraestrutura , Ceratomileuse Assistida por Excimer Laser In Situ/instrumentação , Lasers de Excimer/uso terapêutico , Microscopia Eletrônica de Varredura/métodos , Doadores de Tecidos , Idoso , Idoso de 80 Anos ou mais , Doenças da Córnea/patologia , Substância Própria/cirurgia , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
13.
JAMA Ophthalmol ; 134(5): 487-494, 2016 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-26941076

RESUMO

IMPORTANCE: Intraocular collamer lenses (ICLs) are posterior chamber phakic lenses that provide a refractive surgery option for those with high myopia or astigmatism. The short-term and midterm results indicate good refraction stability, efficacy, and safety. Cataract has been suggested to be an important long-term complication of ICL implantation. OBJECTIVE: To report the rates of cataract development and refractive outcomes 10 years after ICL implantation. DESIGN, SETTING, AND PARTICIPANTS: The study included 133 eyes of 78 patients undergoing consecutive V4 model ICL implantations, which took place from January 1, 1998, through December 31, 2004, at Jules-Gonin Eye Hospital, Lausanne, Switzerland. Data analysis was performed from January 1, 2014, to May 31, 2014. The lenses implanted were as follows: 53 V4 model ICLs of -15.5 D or greater, 73 V4 model ICLs of less than -15.5 diopter (D), and 7 V4 model toric ICLs for myopia. MAIN OUTCOMES AND MEASURES: Rate of cataract surgery, lens opacity, ocular hypertension, refractive safety, predictability, and stability. RESULTS: A total of 133 eyes of 78 patients (34 men and 44 women, with a mean [SD] age of 38.8 [9.2] years at enrollment) met the inclusion criteria. The rate of lens opacity development was 40.9% (95% CI, 32.7%-48.8%) and 54.8% (95% CI, 44.7%-63.0%) at 5 and 10 years, respectively. Phacoemulsification was performed in 5 eyes (4.9%; 95% CI, 1.0%-8.7%) and 18 eyes (18.3%; 95% CI, 10.1%-25.8%) at 5 and 10 years after ICL implantation, respectively. The vault height (distance between the posterior ICL surface and anterior lens surface) measured a mean (SD) of 426 (344) µm immediately postoperatively, decreasing to 213 (169) µm at 10 years. A smaller vault height was associated with the development of lens opacity and phacoemulsification (P = .005 and .008, respectively). The intraocular pressure was 15 mm Hg postoperatively, and there was no significant increase in intraocular pressure observed until the 10-year follow-up (16 mm Hg, P = .02). At 10 years, 12 eyes (12.9%; 95% CI, 5.6%-19.6%) had developed ocular hypertension that required topical medication. At 10 years, the mean (SD) safety index was 1.25 (0.57), with a manifest spherical equivalent of -0.5 D at 1-year postoperatively vs -0.7 D at 10 years postoperatively in eyes aimed at emmetropia. CONCLUSIONS AND RELEVANCE: This retrospective single center study indicates that ICL implantation provides good long-term safety and stability of refraction in patients with high myopia compared with similar short-term studies. However, the rates of cataract formation and ocular hypertension at 10 years have important clinical implications, and as such this information should be part of the available patient information before ICL implantation.

14.
Acta Ophthalmol ; 94(6): e390-4, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26846356

RESUMO

PURPOSE: To compare the postoperative risk of inflammatory relapse in two groups of uveitic patients who underwent cataract surgery: one group had perioperative topical steroids alone and the other used topical and oral steroids. METHODS: Prospective, randomized, unmasked, duocentric clinical trial conducted at the University of Parma (Italy), and the Jules Gonin Eye Hospital of Lausanne (Switzerland). Patients with a history of non-infectious uveitis requiring cataract surgery in 2009-2013 were assigned to two groups of perioperative prophylaxis: (A) intensive topical steroids alone; (B) the same topical regimen combined with oral steroids. Uveitis relapse over a period of 6 months was assessed. RESULTS: In total, 52 eyes in 50 patients were randomized: 28 eyes were assigned to group A (topical) and 24 eyes to group B (topical + oral). Mean relapse-free survival time was 131 ± 11 days in group A and 150 ± 13 days in group B. This difference was not statistically significant (p = 0.42). At the end of follow-up, the groups were also comparable in terms of significant improvement in visual acuity (p < 0.01), mean central macular thickness (CMT) and IOP variation. CONCLUSIONS: Absolute and long-lasting control of ocular, and possibly systemic, inflammation predisposes uveitis patients to satisfactory results after cataract extraction and intraocular lens implantation. Despite a lower rate of recurrences following oral steroid supplementation, the efficacy of an intensive perioperative topical steroid regimen alone in preventing postoperative uveitis relapse was statistically comparable. Secondary outcomes were also comparable between the two groups. Transient IOP elevation should be expected until treatment discontinuation.


Assuntos
Dexametasona/administração & dosagem , Glucocorticoides/administração & dosagem , Implante de Lente Intraocular , Facoemulsificação , Uveíte/prevenção & controle , Administração Oral , Administração Tópica , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Soluções Oftálmicas , Assistência Perioperatória , Estudos Prospectivos , Recidiva , Retina/patologia , Acuidade Visual/fisiologia
15.
Invest Ophthalmol Vis Sci ; 56(9): 5543-7, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26284560

RESUMO

Reaching a consensus in terms of interchangeability and utility (i.e., disease detection/monitoring) of a medical device is the eventual aim of repeatability and agreement studies. The aim of the tolerance and relative utility indices described in this report is to provide a methodology to compare change in clinical measurement noise between different populations (repeatability) or measurement methods (agreement), so as to highlight problematic areas. No longitudinal data are required to calculate these indices. Both indices establish a metric of least to most effected across all parameters to facilitate comparison. If validated, these indices may prove useful tools when combining reports and forming the consensus required in the validation process for software updates and new medical devices.


Assuntos
Consenso , Equipamentos para Diagnóstico/estatística & dados numéricos , Técnicas de Diagnóstico Oftalmológico/instrumentação , Oftalmologia/normas , Software/normas , Técnicas de Diagnóstico Oftalmológico/estatística & dados numéricos , Humanos , Ruído , Reino Unido
16.
Invest Ophthalmol Vis Sci ; 55(9): 5783-7, 2014 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-25052995

RESUMO

PURPOSE: When treating peripheral ectatic disease-like pellucid marginal degeneration (PMD), corneal cross-linking with UV-A and riboflavin (CXL) must be applied eccentrically to the periphery of the lower cornea, partly irradiating the corneal limbus. Here, we investigated the effect of standard and double-standard fluence corneal cross-linking with riboflavin and UV-A (CXL) on cornea and corneal limbus in the rabbit eye in vivo. METHODS: Epithelium-off CXL was performed in male New Zealand White rabbits with two irradiation diameters (7 mm central cornea, 13 mm cornea and limbus), using standard fluence (5.4 J/cm(2)) and double-standard fluence (10.8 J/cm(2)) settings. Controls were subjected to epithelial removal and riboflavin instillation, but were not irradiated with UV-A. Following CXL, animals were examined daily until complete closure of the epithelium, and at 7, 14, 21, and 28 days. Animals were killed and a corneoscleral button was excised and processed for light microscopy and immunohistochemistry. RESULTS: For both irradiation diameters and fluences tested, no signs of endothelial damage or limbal vessel thrombosis were observed, and time to re-epithelialization was similar to untreated controls. Histological and immunohistochemical analysis revealed no differences in the p63 putative stem cell marker expression pattern. CONCLUSIONS: Even when using fluence twice as high as the one used in current clinical CXL settings, circumferential UV-A irradiation of the corneal limbus does not alter the regenerative capacity of the limbal epithelial cells, and the expression pattern of the putative stem cell marker p63 remains unchanged. This suggests that eccentric CXL may be performed safely in PMD.


Assuntos
Córnea/efeitos dos fármacos , Reagentes de Ligações Cruzadas/farmacologia , Limbo da Córnea/efeitos dos fármacos , Fármacos Fotossensibilizantes/farmacologia , Riboflavina/farmacologia , Raios Ultravioleta , Animais , Biomarcadores/metabolismo , Córnea/metabolismo , Epitélio Corneano/metabolismo , Imuno-Histoquímica , Queratina-3/metabolismo , Limbo da Córnea/metabolismo , Masculino , Coelhos , Fatores de Transcrição/metabolismo
17.
Biol Aujourdhui ; 207(2): 97-108, 2013.
Artigo em Francês | MEDLINE | ID: mdl-24103340

RESUMO

According to the World Health Organization, 5.1% of blindnesses or visual impairments are related to corneal opacification. Cornea is a transparent tissue placed in front of the color of the eye. Its transparency is mandatory for vision. The ocular surface is a functional unit including the cornea and all the elements involved in maintaining its transparency i.e., the eyelids, the conjunctiva, the lymphoid tissue of the conjunctiva, the limbus, the lacrymal glands and the tear film. The destruction of the ocular surface is a disease caused by : traumatisms, infections, chronic inflammations, cancers, toxics, unknown causes or congenital abnormalities. The treatment of the ocular surface destruction requires a global strategy including all the elements that are involved in its physiology. The microenvironnement of the ocular surface must first be restored, i.e., the lids, the conjunctiva, the limbus and the structures that secrete the different layers of the tear film. In a second step, the transparency of the cornea can be reconstructed. A corneal graft performed in a healthy ocular surface microenvironnement will have a better survival rate. To achieve these goals, a thorough understanding of the renewal of the epitheliums and the role of the epithelial stem cells are mandatory.


Assuntos
Diferenciação Celular , Túnica Conjuntiva , Córnea , Opacidade da Córnea/etiologia , Opacidade da Córnea/terapia , Epitélio Corneano/fisiologia , Microambiente Celular/fisiologia , Túnica Conjuntiva/anormalidades , Túnica Conjuntiva/citologia , Túnica Conjuntiva/fisiologia , Córnea/anormalidades , Córnea/citologia , Córnea/fisiologia , Opacidade da Córnea/patologia , Células Epiteliais/fisiologia , Epitélio Corneano/citologia , Epitélio Corneano/patologia , Humanos , Células-Tronco/citologia , Células-Tronco/fisiologia
18.
PLoS One ; 8(4): e62095, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23626771

RESUMO

Maintenance of corneal transparency is crucial for vision and depends mainly on the endothelium, a non-proliferative monolayer of cells covering the inner part of the cornea. When endothelial cell density falls below a critical threshold, the barrier and "pump" functions of the endothelium are compromised which results in corneal oedema and loss of visual acuity. The conventional treatment for such severe disorder is corneal graft. Unfortunately, there is a worldwide shortage of donor corneas, necessitating amelioration of tissue survival and storage after harvesting. Recently it was reported that the ROCK inhibitor Y-27632 promotes adhesion, inhibits apoptosis, increases the number of proliferating monkey corneal endothelial cells in vitro and enhance corneal endothelial wound healing both in vitro and in vivo in animal models. Using organ culture human cornea (N = 34), the effect of ROCK inhibitor was evaluated in vitro and ex vivo. Toxicity, corneal endothelial cell density, cell proliferation, apoptosis, cell morphometry, adhesion and wound healing process were evaluated by live/dead assay standard cell counting method, EdU labelling, Ki67, Caspase3, Zo-1 and Actin immunostaining. We demonstrated for the first time in human corneal endothelial cells ex vivo and in vitro, that ROCK inhibitor did not induce any toxicity effect and did not alter cell viability. ROCK inhibitor treatment did not induce human corneal endothelial cells proliferation. However, ROCK inhibitor significantly enhanced adhesion and wound healing. The present study shows that the selective ROCK inhibitor Y-27632 has no effect on human corneal endothelial cells proliferative capacities, but alters cellular behaviours. It induces changes in cell shape, increases cell adhesion and enhances wound healing ex vivo and in vitro. Its absence of toxicity, as demonstrated herein, is relevant for its use in human therapy.


Assuntos
Amidas/farmacologia , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/metabolismo , Endotélio Corneano/metabolismo , Piridinas/farmacologia , Cicatrização/efeitos dos fármacos , Quinases Associadas a rho/antagonistas & inibidores , Amidas/toxicidade , Apoptose/efeitos dos fármacos , Adesão Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Humanos , Piridinas/toxicidade , RNA Mensageiro/genética , RNA Mensageiro/metabolismo , Cicatrização/genética , Quinases Associadas a rho/genética , Quinases Associadas a rho/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA