Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Anal Chem ; 94(38): 13243-13249, 2022 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-36107722

RESUMO

Liposomes are emerging therapeutic formulations for site-specific delivery of chemotherapeutic drugs. The efficiency and selectivity of drug delivery by these carriers largely rely on their surface properties, shape, and size. There is a growing demand for analytical approaches that can be used for structural and morphological characterization of liposomes at the single-vesicle level. AFM-IR is a modern optical nanoscopic technique that combines the advantages of scanning probe microscopy and infrared spectroscopy. Our findings show that AFM-IR can be used to probe conformational changes in phospholipids that take place upon their assembly into liposomes. Such conclusions can be made based on the corresponding changes in intensities of the lipid vibrational bands as the molecules transition from a solid state into large unilamellar vesicles (LUVs). This spectroscopic analysis of LUV formation together with density functional theory calculations also reveals the extent to which the molecular conformation and local environment of the functional groups alter the AFM-IR spectra of phospholipids. Using melittin as a test protein, we also examined the extent to which LUVs can be used for protein internalization. We found that melittin enters LUVs nearly instantaneously, which protects it from possible structural modifications that are caused by a changing environment. This foundational work empowers AFM-IR analysis of liposomes and opens new avenues for determination of the molecular mechanisms of liposome-drug interactions.


Assuntos
Lipossomos , Fosfatidilcolinas , Teoria da Densidade Funcional , Lipossomos/química , Meliteno , Microscopia de Força Atômica , Conformação Molecular , Fosfatidilcolinas/química , Fosfatidilserinas , Fosfolipídeos/química , Espectrofotometria Infravermelho , Lipossomas Unilamelares
2.
Anal Chem ; 94(3): 1804-1812, 2022 01 25.
Artigo em Inglês | MEDLINE | ID: mdl-34931812

RESUMO

Enantioselective chromatography has been the preferred technique for the determination of enantiomeric excess across academia and industry. Although sequential multicolumn enantioselective supercritical fluid chromatography screenings are widespread, access to automated ultra-high-performance liquid chromatography (UHPLC) platforms using state-of-the-art small particle size chiral stationary phases (CSPs) is an underdeveloped area. Herein, we introduce a multicolumn UHPLC screening workflow capable of combining 14 columns (packed with sub-2 µm fully porous and sub-3 µm superficially porous particles) with nine mobile phase eluent choices. This automated setup operates under a vast selection of reversed-phase liquid chromatography, hydrophilic interaction liquid chromatography, polar-organic mode, and polar-ionic mode conditions with minimal manual intervention and high success rate. Examples of highly efficient enantioseparations are illustrated from the integration of chiral screening conditions and computer-assisted modeling. Furthermore, we describe the nuances of in silico method development for chiral separations via second-degree polynomial regression fit using LC simulator (ACD/Labs) software. The retention models were found to be very accurate for chiral resolution of single and multicomponent mixtures of enantiomeric species across different types of CSPs, with differences between experimental and simulated retention times of less than 0.5%. Finally, we illustrate how this approach lays the foundation for a streamlined development of ultrafast enantioseparations applied to high-throughput enantiopurity analysis and its use in the second dimension of two-dimensional liquid chromatography experiments.


Assuntos
Cromatografia de Fase Reversa , Cromatografia Líquida de Alta Pressão/métodos , Cromatografia Líquida , Simulação por Computador , Estereoisomerismo
3.
Analyst ; 147(2): 325-332, 2022 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-34927633

RESUMO

Recent technological and synthetic advances have led to a resurgence in the exploration of peptides as potential therapeutics. Understanding peptide conformation in both free and protein-bound states remains one of the most critical areas for successful development of peptide drugs. In this study it was demonstrated that the combination of Size-Exclusion Chromatography with Hydrogen-Deuterium Exchange Mass Spectrometry (SEC-HDX-MS) and Circular Dichroism Spectroscopy (CD) can be used to guide the selection of peptides for further NMR analysis. Moreover, the insights from this workflow guide the choice of the best biologically relevant conditions for NMR conformational studies of peptide ligands in a free state in solution. Combined information about solution conformation character and stability across temperatures and co-solvent compositions greatly expedites selection of optimal conditions for NMR analysis. In total, the combination of SEC-HDX-MS, CD, and NMR into a single complementary workflow greatly accelerates conformational analysis of peptides in the drug discovery lead optimization process.


Assuntos
Medição da Troca de Deutério , Espectrometria de Massa com Troca Hidrogênio-Deutério , Dicroísmo Circular , Peptídeos , Conformação Proteica , Fluxo de Trabalho
4.
J Sep Sci ; 45(12): 2055-2063, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35108448

RESUMO

Recent advances in the field of cancer biology have accelerated the discovery and development of novel biopharmaceuticals. At the forefront of these drug development efforts are high-throughput screening, compressed timelines, and limited sample quantities, all characteristic of the discovery space. To meet program targets, large numbers of protein variants must be produced, screened, and characterized, presenting a daunting analytical challenge. Additionally, the higher-order structure is paramount for protein function and must be monitored as a critical quality attribute. Matrix-assisted laser desorption/ionization mass spectrometry has been utilized as an ultra-fast, automatable, sample-sparing analytical tool for biomolecules. Our group has published applications integrating hydrogen-deuterium exchange mass spectrometry with matrix-assisted laser desorption/ionization mass spectrometry for the rapid conformational characterization of small proteins, the current work expands this application to monoclonal and bi-specific antibodies. This study demonstrates the ability of the methodology, matrix-assisted laser desorption/ionization hydrogen-deuterium exchange mass spectrometry, to detect conformational differences between bi-specific antibodies from different expression hosts. These conformational differences were validated by orthogonal techniques including circular dichroism, nuclear magnetic resonance, and size-exclusion chromatography hydrogen-deuterium exchange mass spectrometry. This work demonstrates the utility of applying the developed methodology as a rapid conformational screening tool to triage samples for further analytical characterization.


Assuntos
Medição da Troca de Deutério , Hidrogênio , Deutério/química , Deutério/metabolismo , Medição da Troca de Deutério/métodos , Hidrogênio/química , Lasers , Proteínas/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
5.
Angew Chem Int Ed Engl ; 61(21): e202117655, 2022 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-35139257

RESUMO

At the forefront of chemistry and biology research, development timelines are fast-paced and large quantities of pure targets are rarely available. Herein, we introduce a new framework, which is built upon an automated, online trapping-enrichment multi-dimensional liquid chromatography platform (TE-Dt-mDLC) that enables: 1) highly efficient separation of complex mixtures in a first dimension (1 D-UV); 2) automated peak trapping-enrichment and buffer removal achieved through a sequence of H2 O and D2 O washes using an independent pump setup; and 3) a second dimension separation (2 D-UV-MS) with fully deuterated mobile phases and fraction collection to minimize protic residues for immediate NMR analysis while bypassing tedious drying processes and minimizing analyte degradation. Diverse examples of target isolation and characterization from organic synthesis and natural product chemistry laboratories are illustrated, demonstrating recoveries above 90 % using as little as a few micrograms of material.


Assuntos
Produtos Biológicos , Cromatografia Líquida , Espectroscopia de Ressonância Magnética , Solventes
6.
Acc Chem Res ; 52(7): 1990-2002, 2019 07 16.
Artigo em Inglês | MEDLINE | ID: mdl-31198042

RESUMO

Manufacturing process development of new drug substances in the pharmaceutical industry combines numerous chemical challenges beyond the efficient synthesis of complex molecules. Optimization of a synthetic route involves the screening of multiple reaction variables with a desired outcome that not only depends on an increased product yield but is also highly influenced by the removal efficacy of residual chemicals and reaction byproducts during the subsequent synthetic route. Consequently, organic chemists must survey a wide array of synthetic variables to develop a highly productive, green, and cost-effective manufacturing process. The time constraints of developing robust quantitative methods prior to each processing step can easily lead to sample analysis becoming a bottleneck in synthetic route development. In this regard, conventional "on demand" analytical method development and optimization approaches, traditionally used for guiding synthetic chemistry efforts, become unsustainable. This Account introduces recent efforts to address the aforementioned challenges through the development and implementation of generic or more universal chromatographic methods that can cover a broad spectrum of targeted compound classes. Such generic methods require significant resolving power to enable baseline resolution of multicomponent mixtures in a single experimental run without additional method customization but must be simple enough to allow for routine use by chemists, chemical engineers and other researchers with little experience in chromatographic method development. These powerful analytical methodologies are often employed to minimize the time spent developing new analytical assays, while also facilitating method transfer to manufacturing facilities and application in regulatory settings. Diverse examples of universal and fit-for-purpose analytical procedures are presented herein, illustrating the power of modern readily available analytical technology for streamlining the development of new drug substances in organic chemistry laboratories across both academic and industrial sectors. With recent advances in analytical instrumentation and column technologies, universal chromatographic methods are quickly becoming a proactive and effective strategy to accelerate the discovery and implementation of new synthetic methodologies, especially but not limited to laboratories where the synthetic process route is undergoing rapid change and optimization. Targets of these generic methods include analysis of organic solvents, acid and basic additives, nucleotide species, palladium scavengers, impurity mapping, enantiopurity, synthetic intermediates, active pharmaceutical ingredients and their counterions, dehalogenation byproducts, and mixtures of organohalogenated pharmaceuticals, among other chemicals used or formed in process chemistry reactions.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Pesquisa Farmacêutica/métodos , Antineoplásicos/análise , Contaminação de Medicamentos/prevenção & controle , Pesquisa
7.
Anal Bioanal Chem ; 412(11): 2655-2663, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32128644

RESUMO

The analysis of complex mixtures of closely related species is quickly becoming a bottleneck in the development of new drug substances, reflecting the ever-increasing complexity of both fundamental biology and the therapeutics used to treat disease. Two-dimensional liquid chromatography (2D-LC) is emerging as a powerful tool to achieve substantial improvements in peak capacity and selectivity. However, 2D-LC suffers from several limitations, including the lack of automated multicolumn setups capable of combining multiple columns in both dimensions. Herein, we report an investigation into the development and implementation of a customized online comprehensive multicolumn 2D-LC-DAD-MS setup for screening and method development purposes, as well as analysis of multicomponent biopharmaceutical mixtures. In this study, excellent chromatographic performance in terms of selectivity, peak shape, and reproducibility were achieved by combining reversed-phase (RP), strong cation exchange (SCX), strong anion exchange (SAX), and size exclusion chromatography (SEC) using sub-2-µm columns in the first dimension in conjunction with several 3.0 mm × 50 mm RP columns packed with sub-3-µm fully porous particles in the second dimension. Multiple combinations of separation modes coupled to UV and MS detection are applied to the LC × LC analysis of a protein standard mixture, intended to be representative of protein drug substances. The results reported in this study demonstrate that our automated online multicolumn 2D-LC-DAD-MS workflow can be a powerful tool for comprehensive chromatographic column screening that enables the semi-automated development of 2D-LC methods, offering the ability to streamline full visualization of sample composition for an unknown complex mixture while maximizing chromatographic orthogonality. Graphical Abstract.


Assuntos
Cromatografia Líquida/instrumentação , Avaliação Pré-Clínica de Medicamentos/instrumentação , Espectrometria de Massas/instrumentação , Cromatografia em Gel/instrumentação , Cromatografia por Troca Iônica/instrumentação , Cromatografia de Fase Reversa/instrumentação , Descoberta de Drogas/instrumentação , Desenho de Equipamento , Preparações Farmacêuticas/análise , Proteínas/análise , Fluxo de Trabalho
8.
J Nat Prod ; 83(8): 2399-2409, 2020 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-32672460

RESUMO

The first Z-stereoselective method for the synthesis of the natural marine alkynol lembehyne C, containing a 1Z,5Z,9Z-triene moiety, in 41% yield was developed using the new Ti-catalyzed cross-coupling of oxygenated and aliphatic 1,2-dienes as the key step. It was found for the first time that lembehyne C exhibits moderate cytotoxicity against Jurkat, K562, U937, and HL60 cancer cells and also efficiently induces apoptosis in Jurkat cells, with the cell death mechanism being activated by the mitochondrial pathway. The lembehyne C inhibition of the cell cycle follows the mitotic catastrophe mechanism.


Assuntos
Antineoplásicos/farmacologia , Linhagem Celular Tumoral , Ensaios de Seleção de Medicamentos Antitumorais , Humanos , Estereoisomerismo
9.
Bioorg Chem ; 104: 104303, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33011528

RESUMO

A stereoselective method was developed for the synthesis of synthetic analogues of natural 5Z,9Z-dienoic acids by esterification of aliphatic and aromatic alcohols and carboxylic acids with (5Z,9Z)-1,14-tetradeca-5,9-dienedioic acid and (5Z,9Z)-1,14-tetradeca-5,9-dienediol, synthesized by Ti-catalyzed homo-cyclomagnesiation of the tetrahydropyran ether of hepta-5,6-dien-1-ol with Grignard reagents. In order to establish the effect of molecular structure on the antitumor activity, the obtained 5Z,9Z-dienoic acids were tested for the inhibitory activity against human topoisomerase I, the cytotoxic activity in vitro against several cancer and normal cell lines (Jurkat, HL-60, K562, U937, fibroblasts), the effect on the cell cycle, and apoptosis-inducing ability using flow cytofluorometry. In addition, the effect of the synthesized acids on the cancer cell production of some phosphorylated and unphosphorylated proteins responsible for proliferation and apoptosis was studied by a new multiplex assay technology, MAGPIX.


Assuntos
Antineoplásicos/farmacologia , Produtos Biológicos/farmacologia , DNA Topoisomerases Tipo I/metabolismo , Ácidos Graxos Insaturados/farmacologia , Inibidores da Topoisomerase I/farmacologia , Antineoplásicos/síntese química , Antineoplásicos/química , Apoptose/efeitos dos fármacos , Produtos Biológicos/síntese química , Produtos Biológicos/química , Proliferação de Células/efeitos dos fármacos , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Relação Dose-Resposta a Droga , Ensaios de Seleção de Medicamentos Antitumorais , Ácidos Graxos Insaturados/síntese química , Ácidos Graxos Insaturados/química , Humanos , Estrutura Molecular , Estereoisomerismo , Relação Estrutura-Atividade , Inibidores da Topoisomerase I/síntese química , Inibidores da Topoisomerase I/química
10.
Anal Chem ; 91(21): 13907-13915, 2019 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-31549812

RESUMO

Chromatographic separation, analysis and characterization of complex highly polar analyte mixtures can often be very challenging using conventional separation approaches. Analysis and purification of hydrophilic compounds have been dominated by liquid chromatography (LC) and ion-exchange chromatography (IC), with sub/supercritical fluid chromatography (SFC) moving toward these new applications beyond traditional chiral separations. However, the low polarity of supercritical carbon dioxide (CO2) has limited the use of SFC for separation and purification in the bioanalytical space, especially at the preparative scale. Reaction mixtures of highly polar species are strongly retained even using polar additives in alcohol modifier/CO2 based eluents. Herein, we overcome these problems by introducing chaotropic effects in SFC separations using a nontraditional mobile phase mixture consisting of ammonium hydroxide combined with high water concentration in the alcohol modifier and carbon dioxide. The separation mechanism was here elucidated based on extensive IC-CD (IC couple to conductivity detection) analysis of cyclic peptides subjected to the SFC conditions, indicating the in situ formation of a bicarbonate counterion (HCO3-). In contrast to other salts, HCO3- was found to play a crucial role acting as a chaotropic agent that disrupts undesired H-bonding interactions, which was demonstrated by size-exclusion chromatography coupled with differential hydrogen-deuterium exchange-mass spectrometry experiments (SEC-HDX-MS). In addition, the use of NH4OH in water-rich MeOH modifiers was compared to other commonly used basic additives (diethylamine, triethylamine, and isobutylamine) showing unmatched chromatographic and MS detection performance in terms of peak shape, retention, selectivity, and ionization as well as a completely different selectivity and retention behavior. Moreover, relative to ammonium formate and ammonium acetate in water-rich methanol modifier, the ammonium hydroxide in water additive showed better chromatographic performance with enhanced sensitivity. Further optimization of NH4OH and H2O levels in conjunction with MeOH/CO2 served to furnish a generic modifier (0.2% NH4OH, 5% H2O in MeOH) that enables the widespread transition of SFC to domains that were previously considered out of its scope. This approach is extensively applied to the separation, analysis, and purification of multicomponent reaction mixtures of closely related polar pharmaceuticals using readily available SFC instrumentation. The examples described here cover a broad spectrum of bioanalytical and pharmaceutical applications including analytical and preparative chromatography of organohalogenated species, nucleobases, nucleosides, nucleotides, sulfonamides, and cyclic peptides among other highly polar species.


Assuntos
Hidróxido de Amônia/química , Cromatografia com Fluido Supercrítico/métodos , Peptídeos/isolamento & purificação , Preparações Farmacêuticas/isolamento & purificação , Água/química , Dióxido de Carbono/química , Ligação de Hidrogênio , Espectrometria de Massa com Troca Hidrogênio-Deutério/métodos , Interações Hidrofóbicas e Hidrofílicas , Metanol/química
11.
Analyst ; 144(9): 2872-2880, 2019 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-30830135

RESUMO

Modern process research and development can often be hampered by the tedious method development required to chromatographically resolve mixtures of chemical species with very similar physical properties. Herein, we describe a simple approach for the development and implementation of an efficient ultra-high performance liquid chromatography (UHPLC) assay that is extensively applied to the separation and analysis of multicomponent reaction mixtures of closely related pharmaceutical intermediates and impurities. Methods are optimized using multi-column and multi-solvent UHPLC screening in conjunction with chromatography simulation software (ACD Labs/LC Simulator). This approach is implemented to enable the separation, identification, mapping and control of impurities formed within the process chemistry optimization of the dimeric catalyst used in the synthesis of new drug substances. The final method utilized a sub-2 µm C18 stationary phase (2.1 mm I.D. × 50 mm length, 1.7 µm particle size ACQUITY UPLC BEH C18) with a non-conventional chaotropic mobile phase buffer (35 mM potassium hexafluorophosphate in 0.1% phosphoric acid/acetonitrile) in order to achieve baseline separation of all reaction components. The chromatographic simulation and modeling strategy served to generate 3D resolution maps with robust separation conditions that match the outcome of subsequent experimental data (overall ΔtR < 0.35%). Our multi-column UHPLC screening with computer-assisted chromatographic modeling is a great addition to the toolbox of synthetic chemists and can be a powerful tool for streamlining process chemistry optimization in organic chemistry laboratories across both academic and industrial sectors.


Assuntos
Carbamatos/isolamento & purificação , Cromatografia Líquida de Alta Pressão/métodos , Compostos Heterocíclicos com 2 Anéis/isolamento & purificação , Cromatografia Líquida de Alta Pressão/instrumentação , Simulação por Computador
12.
J Comput Aided Mol Des ; 32(10): 1117-1138, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30406372

RESUMO

Determining the net charge and protonation states populated by a small molecule in an environment of interest or the cost of altering those protonation states upon transfer to another environment is a prerequisite for predicting its physicochemical and pharmaceutical properties. The environment of interest can be aqueous, an organic solvent, a protein binding site, or a lipid bilayer. Predicting the protonation state of a small molecule is essential to predicting its interactions with biological macromolecules using computational models. Incorrectly modeling the dominant protonation state, shifts in dominant protonation state, or the population of significant mixtures of protonation states can lead to large modeling errors that degrade the accuracy of physical modeling. Low accuracy hinders the use of physical modeling approaches for molecular design. For small molecules, the acid dissociation constant (pKa) is the primary quantity needed to determine the ionic states populated by a molecule in an aqueous solution at a given pH. As a part of SAMPL6 community challenge, we organized a blind pKa prediction component to assess the accuracy with which contemporary pKa prediction methods can predict this quantity, with the ultimate aim of assessing the expected impact on modeling errors this would induce. While a multitude of approaches for predicting pKa values currently exist, predicting the pKas of drug-like molecules can be difficult due to challenging properties such as multiple titratable sites, heterocycles, and tautomerization. For this challenge, we focused on set of 24 small molecules selected to resemble selective kinase inhibitors-an important class of therapeutics replete with titratable moieties. Using a Sirius T3 instrument that performs automated acid-base titrations, we used UV absorbance-based pKa measurements to construct a high-quality experimental reference dataset of macroscopic pKas for the evaluation of computational pKa prediction methodologies that was utilized in the SAMPL6 pKa challenge. For several compounds in which the microscopic protonation states associated with macroscopic pKas were ambiguous, we performed follow-up NMR experiments to disambiguate the microstates involved in the transition. This dataset provides a useful standard benchmark dataset for the evaluation of pKa prediction methodologies on kinase inhibitor-like compounds.


Assuntos
Modelos Químicos , Inibidores de Proteínas Quinases/química , Bibliotecas de Moléculas Pequenas/química , Compostos Heterocíclicos com 1 Anel/química , Compostos Heterocíclicos com 2 Anéis/química , Concentração de Íons de Hidrogênio , Modelos Moleculares , Solventes/química , Termodinâmica , Raios Ultravioleta , Água/química
13.
Anal Chem ; 89(16): 8351-8357, 2017 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-28727449

RESUMO

Matrix-assisted laser desorption/ionization (MALDI) coupled with a time-of-flight (TOF) mass-spectrometry (MS) detector is acknowledged to be very useful for analysis of biological molecules. At the same time, hydrogen-deuterium exchange (HDX) is a well-known technique for studying protein higher-order structure. However, coupling MALDI with HDX has been challenging because of undesired back-exchange reactions during analysis. In this report, we survey an approach that utilizes MALDI coupled with an automated sample preparation to compare global conformational changes of proteins under different solution conditions using differential HDX. A nonaqueous matrix was proposed for MALDI sample preparation to minimize undesirable back-exchange. An automated experimental setup based on the use of a liquid-handling robot and automated data acquisition allowed for tracking protein conformational changes as a difference in the number of protons exchanged to deuterons at specified solution conditions. Experimental time points to study the deuteration-labeling kinetics were obtained in a fully automated manner. The use of a nonaqueous matrix solution allowed experimental error to be minimized to within 1% RSD. We applied this newly developed MALDI-HDX workflow to study the effect of several common excipients on insulin folding stability. The observed results were corroborated by literature data and were obtained in a high-throughput and automated manner. The proposed MALDI-HDX approach can also be applied in a high-throughput manner for batch-to-batch higher-order structure comparison, as well as for the optimization of protein chemical modification reactions.


Assuntos
Insulina/química , Ubiquitina/química , Animais , Bovinos , Medição da Troca de Deutério , Humanos , Conformação Proteica , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
14.
Anal Chem ; 89(6): 3545-3553, 2017 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-28192943

RESUMO

Chromatographic separation and analysis of complex mixtures of closely related species is one of the most challenging tasks in modern pharmaceutical analysis. In recent years, two-dimensional liquid chromatography (2D-LC) has become a valuable tool for improving peak capacity and selectivity. However, the relatively slow speed of chiral separations has limited the use of chiral stationary phases (CSPs) as the second dimension in 2D-LC, especially in the comprehensive mode. Realizing that the recent revolution in the field of ultrafast enantioselective chromatography could now provide significantly faster separations, we herein report an investigation into the use of ultrafast chiral chromatography as a second dimension for 2D chromatographic separations. In this study, excellent selectivity, peak shape, and repeatability were achieved by combining achiral and chiral narrow-bore columns (2.1 mm × 100 mm and 2.1 mm × 150 mm, sub-2 and 3 µm) in the first dimension with 4.6 mm × 30 mm and 4.6 mm × 50 mm columns packed with highly efficient chiral selectors (sub-2 µm fully porous and 2.7 µm fused-core particles) in the second dimension, together with the use of 0.1% phosphoric acid/acetonitrile eluents in both dimensions. Multiple achiral × chiral and chiral × chiral 2D-LC examples (single and multiple heart-cutting, high-resolution sampling, and comprehensive) using ultrafast chiral chromatography in the second dimension are successfully applied to the separation and analysis of complex mixtures of closely related pharmaceuticals and synthetic intermediates, including chiral and achiral drugs and metabolites, constitutional isomers, stereoisomers, and organohalogenated species.


Assuntos
Varfarina/química , Cromatografia Líquida/instrumentação , Estrutura Molecular , Varfarina/análogos & derivados
15.
Org Biomol Chem ; 15(3): 555-558, 2017 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-27942665

RESUMO

Temperature dependent inversion of enantioselectivity in asymmetric catalysis is an interesting and somewhat unusual phenomenon. We have observed temperature dependent inversion of enantioselectivity in the asymmetric autocatalysis reaction when triggered by a wide scope of enantioenriched alcohols and amines. The addition reaction of diisopropylzinc to pyrimidine-5-carbaldehyde in the presence of enantiopure alcohols or amines affords the pyrimidyl alkanol product at 0 °C with high ee. However, lowering the reaction temperature to -44 °C affords the opposite enantioselectivity.

16.
Org Biomol Chem ; 14(19): 4448-55, 2016 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-27088756

RESUMO

Using hydrostatic pressure to induce protein conformational changes can be a powerful tool for altering the availability of protein reactive sites and for changing the selectivity of enzymatic reactions. Using a pressure apparatus, it has been demonstrated that hydrostatic pressure can be used to modulate the reactivity of lysine residues of the protein ubiquitin with a water-soluble amine-specific homobifunctional coupling agent. Fewer reactive lysine residues were observed when the reaction was carried out under elevated pressure of 3 kbar, consistent with a pressure-induced conformational change of ubiquitin that results in fewer exposed lysine residues. Additionally, modulation of the stereoselectivity of an enzymatic transamination reaction was observed at elevated hydrostatic pressure. In one case, the minor diasteromeric product formed at atmospheric pressure became the major product at elevated pressure. Such pressure-induced alterations of protein reactivity may provide an important new tool for enzymatic reactions and the chemical modification of proteins.


Assuntos
Enzimas/química , Enzimas/metabolismo , Proteínas/química , Proteínas/metabolismo , Aminas/química , Animais , Pressão Hidrostática , Ligação Proteica , Solubilidade , Especificidade por Substrato , Água/química
17.
Org Biomol Chem ; 15(1): 96-101, 2016 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-27714244

RESUMO

An investigation is reported on the use of the autocatalytic enantioselective Soai reaction, known to be influenced by the presence of a wide variety of chiral materials, as a generic tool for measuring the enantiopurity and absolute configuration of any substance. Good generality for the reaction across a small group of test analytes was observed, consistent with literature reports suggesting a diversity of compound types that can influence the stereochemical outcome of this reaction. Some trends in the absolute sense of stereochemical enrichment were noted, suggesting the possible utility of the approach for assigning absolute configuration to unknown compounds, by analogy to closely related species with known outcomes. Considerable variation was observed in the triggering strength of different enantiopure materials, an undesirable characteristic when dealing with mixtures containing minor impurities with strong triggering strength in the presence of major components with weak triggering strength. A strong tendency of the reaction toward an 'all or none' type of behavior makes the reaction most sensitive for detecting enantioenrichment close to zero. Consequently, the ability to discern modest from excellent enantioselectivity was relatively poor. While these properties limit the ability to obtain precise enantiopurity measurements in a simple single addition experiment, prospects may exist for more complex experimental setups that may potentially offer improved performance.

18.
Anal Chem ; 87(4): 2396-402, 2015 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-25620238

RESUMO

The market of protein therapeutics is exploding, and characterization methods for proteins are being further developed to understand and explore conformational structures with regards to function and activity. There are several spectroscopic techniques that allow for analyzing protein secondary structure in solution. However, a majority of these techniques need to use purified protein, concentrated enough in the solution to produce a relevant spectrum. In this study, we describe a novel approach which uses ultrahigh pressure liquid chromatography (UHPLC) coupled with mass-spectrometry (MS) to explore compressibility of the secondary structure of proteins under increasing pressure detected by hydrogen-deuterium exchange (HDX). Several model proteins were used for these studies. The studies were conducted with UHPLC in isocratic mode at constant flow rate and temperature. The pressure was modified by a backpressure regulator up to about 1200 bar. It was found that the increase of retention factors upon pressure increase, at constant flow rate and temperature, was based on reduction of the proteins' molecular molar volume. The change in the proteins' molecular molar volume was caused by changes in protein folding, as was revealed by differential deuterium exchange. The degree of protein folding under certain UHPLC conditions can be controlled by pressure, at constant temperature and flow rate. By modifying pressure during UHPLC separation, it was possible to achieve changes in protein folding, which were manifested as changes in the number of labile protons exchanged to deuterons, or vice versa. Moreover, it was demonstrated with bovine insulin that a small difference in the number of protons exchanged to deuterons (based on protein folding under pressure) could be observed between batches obtained from different sources. The use of HDX during UHPLC separation allowed one to examine protein folding by pressure at constant flow rate and temperature in a mixture of sample solution with minimal amounts of sample used for analysis.


Assuntos
Cromatografia de Fase Reversa , Medição da Troca de Deutério , Pressão , Conformação Proteica , Animais , Bradicinina/química , Bovinos , Citocromos c/química , Citocromos c/metabolismo , Cavalos , Humanos , Insulina/química , Espectrometria de Massas , Mioglobina/química , Dobramento de Proteína , Temperatura , Uracila/química
19.
Anal Chem ; 86(1): 805-13, 2014 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-24359254

RESUMO

In recent years, the use of halogen-containing molecules has proliferated in the pharmaceutical industry, where the incorporation of halogens, especially fluorine, has become vitally important for blocking metabolism and enhancing the biological activity of pharmaceuticals. The chromatographic separation of halogen-containing pharmaceuticals from associated isomers or dehalogenation impurities can sometimes be quite difficult. In an attempt to identify the best current tools available for addressing this important problem, a survey of the suitability of four chromatographic method development platforms (ultra high-performance liquid chromatography (UHPLC), core shell HPLC, achiral supercritical fluid chromatography (SFC) and chiral SFC) for separating closely related mixtures of halogen-containing pharmaceuticals and their dehalogenated isosteres is described. Of the 132 column and mobile phase combinations examined for each mixture, a small subset of conditions were found to afford the best overall performance, with a single UHPLC method (2.1 × 50 mm, 1.9 µm Hypersil Gold PFP, acetonitrile/methanol based aqueous eluents containing either phosphoric or perchloric acid with 150 mM sodium perchlorate) affording excellent separation for all samples. Similarly, a survey of several families of closely related halogen-containing small molecules representing the diversity of impurities that can sometimes be found in purchased starting materials for synthesis revealed chiral SFC (Chiralcel OJ-3 and Chiralpak IB, isopropanol or ethanol with 25 mM isobutylamine/carbon dioxide) as well as the UHPLC (2.1 × 50 mm, 1.8 µm ZORBAX RRHD Eclipse Plus C18 and the Gold PFP, acetonitrile/methanol based aqueous eluents containing phosphoric acid) as preferred methods.


Assuntos
Química Farmacêutica/métodos , Contaminação de Medicamentos , Halogenação , Halogênios/análise , Cromatografia Líquida de Alta Pressão/métodos , Halogênios/química , Isomerismo
20.
J Pharm Biomed Anal ; 229: 115350, 2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-37001275

RESUMO

Peptides have gained an increasing importance in drug discovery as potential therapeutics. Discovery efforts toward finding new, efficacious peptide-based therapeutics have increased the throughput of peptide development, allowing the rapid generation of unique and pure peptide samples. However, high-throughput analysis of peptides may be still challenging and can encumber a high-throughput drug discovery campaign. We report herein a fit-for-purpose method to quantify peptide concentrations using high-throughput infrared spectroscopy (HT-IR). Through the development of this method, multiple critical method parameters were optimized including solvent composition, droplet deposition size, plate drying procedures, sample concentration, and internal standard. The relative absorbance of the amide region (1600-1750 cm-1) to the internal standard, K3Fe(CN)6 (2140 cm-1), was determined to be most effective at providing lowest interference for measuring peptide concentration. The best sample deposition was achieved by dissolving samples in a 50:50 v/v allyl alcohol/water mixture. The developed method was used on 96-well plates and analyzed at a rate of 22 min per plate. Calibration curves to measure sample concentration versus response relationship displayed sufficient linearity (R2 > 0.95). The repeatability and scope of detection was demonstrated with eighteen peptide samples that were measured with most values below 20% relative standard deviation. The linear dynamic range of the method was determined to be between 1 and 5 mg/mL. This developed HT-IR methodology could be a useful tool in peptide drug candidate lead identification and optimization processes.


Assuntos
Descoberta de Drogas , Peptídeos , Peptídeos/química , Espectrofotometria Infravermelho , Solventes/química , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA