Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur Heart J ; 34(28): 2132-40, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23782649

RESUMO

AIMS: Catheter-based renal artery sympathetic denervation has emerged as a novel therapy for treatment of patients with drug-resistant hypertension. Initial studies were performed using a single electrode radiofrequency catheter, but recent advances in catheter design have allowed the development of multi-electrode systems that can deliver lesions with a pre-determined pattern. This study was designed to evaluate the safety and efficacy of the EnligHTN(™) multi-electrode system. METHODS AND RESULTS: We conducted the first-in-human, prospective, multi-centre, non-randomized study in 46 patients (67% male, mean age 60 years, and mean baseline office blood pressure 176/96 mmHg) with drug-resistant hypertension. The primary efficacy objective was change in office blood pressure from baseline to 6 months. Safety measures included all adverse events with a focus on the renal artery and other vascular complications and changes in renal function. Renal artery denervation, using the EnligHTN system significantly reduced the office blood pressure from baseline to 1, 3, and 6 months by -28/10, -27/10 and -26/10 mmHg, respectively (P < 0.0001). No acute renal artery injury or other serious vascular complications occurred. Small, non-clinically relevant, changes in average estimated glomerular filtration rate were reported from baseline (87 ± 19 mL/min/1.73 m2) to 6 months post-procedure (82 ± 20 mL/min/1.73 m2). CONCLUSION: Renal sympathetic denervation, using the EnligHTN multi-electrode catheter results in a rapid and significant office blood pressure reduction that was sustained through 6 months. The EnligHTN system delivers a promising therapy for the treatment of drug-resistant hypertension.


Assuntos
Ablação por Cateter/métodos , Hipertensão/cirurgia , Simpatectomia/métodos , Adolescente , Adulto , Idoso , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea/fisiologia , Monitorização Ambulatorial da Pressão Arterial , Ablação por Cateter/instrumentação , Creatinina/metabolismo , Cistatina C/metabolismo , Eletrodos , Feminino , Taxa de Filtração Glomerular/fisiologia , Humanos , Hipertensão/tratamento farmacológico , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Artéria Renal/inervação , Simpatectomia/instrumentação , Resultado do Tratamento , Adulto Jovem
2.
Int J Cardiol ; 201: 345-50, 2015 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-26301677

RESUMO

BACKGROUND: Long term safety and efficacy data of multi-electrode ablation system for renal denervation (RDN) in patients with drug resistant hypertension (dRHT) are limited. METHODS AND RESULTS: We studied 46 patients (age: 60 ± 10 years, 4.7 ± 1.0 antihypertensive drugs) with drug resistant hypertension (dRHT). Reduction in office BP at 24 months from baseline was -29/-13 mmHg, while the reduction in 24-hour ambulatory BP and in home BP at 24 months were -13/-7 mmHg and -11/-6 mmHg respectively (p<0.05 for all). A correlation analysis revealed that baseline office and ambulatory BP were related to the extent of office and ambulatory BP drop. Apart from higher body mass index (33.3 ± 4.7 vs 29.5 ± 6.2 kg/m(2), p<0.05), there were no differences in patients that were RDN responders defined as ≥10 mmHg decrease (74%, n=34) compared to non-responders. Stepwise logistic regression analysis revealed no prognosticators of RDN response (p=NS for all). At 24 months there were no new serious device or procedure related adverse events. CONCLUSIONS: The EnligHTN I study shows that the multi-electrode ablation system provides a safe method of RDN in dRHT accompanied by a clinically relevant and sustained BP reduction.


Assuntos
Ablação por Cateter/métodos , Hipertensão/cirurgia , Rim/inervação , Rim/cirurgia , Simpatectomia/métodos , Idoso , Pressão Sanguínea/fisiologia , Monitorização Ambulatorial da Pressão Arterial , Índice de Massa Corporal , Ablação por Cateter/efeitos adversos , Resistência a Medicamentos , Eletrodos , Feminino , Seguimentos , Humanos , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Simpatectomia/efeitos adversos , Resultado do Tratamento
3.
Hypertension ; 64(3): 565-72, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24935940

RESUMO

Renal denervation has emerged as a novel approach for the treatment of patients with drug-resistant hypertension. To date, only limited data have been published using multielectrode radiofrequency ablation systems. In this article, we present the 12-month data of EnligHTN I, a first-in-human study using a multielectrode ablation catheter. EnligHTN I enrolled 46 patients (average age, 60±10 years; on average 4.7±1.0 medications) with drug-resistant hypertension. Eligible patients were on ≥3 antihypertensive medications and had a systolic blood pressure (BP) ≥160 mm Hg (≥150 mm Hg for diabetics). Bilateral renal artery ablation was performed using a percutaneous femoral approach and standardized techniques. The average baseline office BP was 176/96 mm Hg, average 24-hour ambulatory BP was 150/83 mm Hg, and average home BP was 158/90 mm Hg. The average reductions (mm Hg) at 1, 3, 6, and 12 months were as follows: office: -28/-10, -27/-10, -26/-10, and -27/-11 mm Hg (P<0.001 for all); 24-hour ambulatory: -10/-5, -10/-5, -10/-6 (P<0.001 for all), and -7/-4 for 12 months (P<0.0094). Reductions in home measurements (based on 2-week average) were -9/-4, -8/-5,-10/-7, and -11/-6 mm Hg (P<0.001 at 12 months). At 12 months, there were no signals of worsening renal function and no new serious or life-threatening adverse events. One patient with baseline nonocclusive renal artery stenosis progressed to 75% diameter stenosis, requiring renal artery stenting. The 12-month data continue to demonstrate safety and efficacy of the EnligHTN ablation system in patients with drug-resistant hypertension. Home BP measurements parallel measurements obtained with 24-hour ambulatory monitoring.


Assuntos
Anti-Hipertensivos/uso terapêutico , Ablação por Cateter/métodos , Denervação/métodos , Hipertensão/tratamento farmacológico , Hipertensão/cirurgia , Artéria Renal/inervação , Idoso , Pressão Sanguínea/fisiologia , Monitorização Ambulatorial da Pressão Arterial , Ablação por Cateter/instrumentação , Resistência a Medicamentos , Feminino , Seguimentos , Humanos , Hipertensão/fisiopatologia , Incidência , Rim/irrigação sanguínea , Rim/inervação , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Obstrução da Artéria Renal/epidemiologia , Obstrução da Artéria Renal/cirurgia , Stents , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA