Radiat Prot Dosimetry ; 200(3): 229-239, 2024 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-38069535

RESUMO

The aim of this study was to determine the entrance surface air kerma (ESAK) in adult patients during digital radiography and to evaluate the optimisation potential in five common X-ray examinations in Tanzania. Based on a sample of 240-610 patients, ESAK was estimated using X-ray tube output measurements, patient information and backscatter factors. The results show that the mean ESAK values were higher or comparable to data from the literature. The diagnostic reference values of ESAK for digital radiography were 0.31 mGy (chest PA), 4 mGy (lumbar spine AP), 5.4 mGy (lumbar spine LAT), 3.8 mGy (abdomen AP) and 2.4 mGy (pelvis AP). For computed radiography, the mean ESAK ranges were 0.44-0.57 mGy (thoracic AP), 3.59-3.72 mGy (lumbar spine AP), 6.16-6.35 mGy (lumbar spine LAT), 3.89-3.44 mGy (abdominal AP) and 2.92-3.47 mGy (pelvic AP). In conclusion, high ESAK variations show the potential for optimising protection in digital radiology.


Assuntos
Vértebras Lombares , Intensificação de Imagem Radiográfica , Adulto , Humanos , Doses de Radiação , Tanzânia , Radiografia , Vértebras Lombares/diagnóstico por imagem , Fluoroscopia , Intensificação de Imagem Radiográfica/métodos