RESUMO
BACKGROUND: Acute human immunodeficiency virus type 1 (HIV-1) infection is a major contributor to transmission of HIV-1. An understanding of acute HIV-1 infection may be important in the development of treatment strategies to eradicate HIV-1 or achieve a functional cure. METHODS: We performed twice-weekly qualitative plasma HIV-1 RNA nucleic acid testing in 2276 volunteers who were at high risk for HIV-1 infection. For participants in whom acute HIV-1 infection was detected, clinical observations, quantitative measurements of plasma HIV-1 RNA levels (to assess viremia) and HIV antibodies, and results of immunophenotyping of lymphocytes were obtained twice weekly. RESULTS: Fifty of 112 volunteers with acute HIV-1 infection had two or more blood samples collected before HIV-1 antibodies were detected. The median peak viremia (6.7 log10 copies per milliliter) occurred 13 days after the first sample showed reactivity on nucleic acid testing. Reactivity on an enzyme immunoassay occurred at a median of 14 days. The nadir of viremia (4.3 log10 copies per milliliter) occurred at a median of 31 days and was nearly equivalent to the viral-load set point, the steady-state viremia that persists durably after resolution of acute viremia (median plasma HIV-1 RNA level, 4.4 log10 copies per milliliter). The peak viremia and downslope were correlated with the viral-load set point. Clinical manifestations of acute HIV-1 infection were most common just before and at the time of peak viremia. A median of one symptom of acute HIV-1 infection was recorded at a median of two study visits, and a median of one sign of acute HIV-1 infection was recorded at a median of three visits. CONCLUSIONS: The viral-load set point occurred at a median of 31 days after the first detection of plasma viremia and correlated with peak viremia. Few symptoms and signs were observed during acute HIV-1 infection, and they were most common before peak viremia. (Funded by the Department of Defense and the National Institute of Allergy and Infectious Diseases.).
Assuntos
Infecções por HIV/diagnóstico , HIV-1 , Viremia/diagnóstico , Adolescente , Adulto , África Oriental , Anticorpos Antivirais/sangue , Contagem de Linfócito CD4 , Progressão da Doença , Feminino , Infecções por HIV/virologia , HIV-1/genética , HIV-1/imunologia , HIV-1/isolamento & purificação , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , RNA Viral/sangue , Tailândia , Carga ViralRESUMO
The Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 test, v2.0 (the CAP/CTM assay), was used to quantify cell-associated HIV-1 (CAH) nucleic acid in peripheral blood mononuclear cells (PBMC) from well-characterized clinical specimens from HIV-1-infected individuals on antiretroviral therapy (ART). Chronically infected individuals on ART with no detectable plasma HIV-1 RNA demonstrated average CAH burdens of 3.2 HIV-1 log10 copies/million cells. Assay sensitivity and specificity were 98.9% and 100%, respectively, with the positive and negative predictive values being 100% and 98.6%, respectively. The CAH burden was also measured at weeks 0, 1, 2, 8, and 60 in 37 participants (RV254/SEARCH010, Bangkok, Thailand) stratified by Fiebig stage (Fiebig stage I [FI] to FVI) at ART initiation. Prior to ART initiation, the average CAH burden was 1.4, 4.1, and 3.6 log10 copies/million PBMCs for individuals who initiated ART at FI, FII, and FIII to FVI, respectively. Initiation of ART resulted in a rapid decline of CAH in all individuals, with the greatest decrease being observed in individuals who initiated ART at FI to FIII. By week 60, 100% (FI), 71.8% (FII/FIII), and 20.5% (FIV to FVI) of samples from individuals initiating treatment were at or near the limit of quantitation. Residual CAH was detectable at 60 weeks in most individuals who initiated ART at later stages (FIV to FVI) and averaged 1.9 ± 0.7 log10 copies/million PBMCs. The modified Roche CAP/CTM assay provides a convenient, standardized approach to measure residual HIV in blood and may be useful for monitoring patients under therapy or those participating in HIV remission studies.
Assuntos
Antirretrovirais/uso terapêutico , Infecções por HIV/tratamento farmacológico , Leucócitos Mononucleares/virologia , RNA Viral/sangue , Adolescente , Adulto , Infecções por HIV/sangue , HIV-1 , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Kit de Reagentes para Diagnóstico , Sensibilidade e Especificidade , Manejo de Espécimes , Carga Viral , Adulto JovemRESUMO
Antiretroviral therapy (ART) during acute HIV infection (AHI) interrupts viral dynamics and may delay the emergence of serological markers targeted by current HIV screening and confirmatory assays, thus creating challenges for correctly classifying HIV infection status. The performance of three HIV antigen/antibody combination (HIV Ag/Ab Combo) assays (the Bio-Rad GS, Abbott Architect, and Bio-Rad BioPlex 2200 assays) was evaluated with samples collected from RV254/South East Asia Research Collaboration in HIV 010 (RV254/SEARCH010) study (Bangkok, Thailand) participants at weeks 12 and 24 following the initiation of ART at Fiebig stage I (FI) (n = 23), FII (n = 39), or FIII/IV (n = 22). Supplemental, confirmatory testing was performed by the Geenius HIV 1/2 and HIV-1 Western blot assays (Bio-Rad). Samples from 30 untreated, HIV-1-infected individuals demonstrated robust HIV Ag/Ab Combo assay reactivity with well-developed HIV-1 Western blotting profiles by 24 weeks after infection. In contrast, 52.2% of samples from individuals initiating ART at FI, 7.7% of samples from individuals initiating ART at FII, and 4.5% of samples from individuals initiating ART at FIII/IV were nonreactive by the HIV Ag/Ab Combo assays, with 36.4 to 39.1% of samples having low signal-to-cutoff (S/CO) results by the Architect and BioPlex assays (S/CO < 10). Seroreversion from a reactive to a nonreactive status was observed in 10 individuals initiating ART at FII and 3 individuals initiating ART at FIII/IV. The Geenius and HIV-1 Western blot assay results were negative or indeterminate for 73.9% and 69.6% of individuals, respectively, treated at FI; 50.0% and 26.3% of individuals, respectively, treated at FII; and 54.5% and 40.9% of individuals, respectively, treated at FIII/IV. Virologic suppression of HIV-1 by ART during AHI impedes seroconversion to biomarkers of infection, limiting the utility of HIV Ag/Ab Combo and supplemental, confirmatory assays for infection status determination.
Assuntos
Infecções por HIV/diagnóstico , Infecções por HIV/virologia , HIV , Fármacos Anti-HIV/administração & dosagem , Fármacos Anti-HIV/uso terapêutico , Terapia Antirretroviral de Alta Atividade , Feminino , HIV/genética , HIV/imunologia , Anticorpos Anti-HIV/imunologia , Antígenos HIV/imunologia , Infecções por HIV/tratamento farmacológico , Infecções por HIV/imunologia , Soropositividade para HIV , Humanos , Imunoensaio , Masculino , RNA Viral , Testes Sorológicos , Resultado do TratamentoRESUMO
Dried blood spots (DBS) are frequently used in clinical testing for biosurveillance, infectious disease and confirmatory testing, and clinical trials, particularly for populations in remote areas. The HemaSpot-HF blood collection device (HS) provides an alternative format to the Whatman 903 cards (903) to simplify sample collection and processing. In this study, the performance of the HS was compared to that of the 903 using previously characterized clinical specimens and HIV seroconversion panels known to exhibit markers of early human immunodeficiency virus (HIV) infection. HS and 903 samples were prepared and tested by Bio-Rad GS HIV Combo Ag/Ab enzyme immunoassay (EIA), GS HIV-1/-2 Plus O EIA, GS HIV-1 Western blot, and HIV-1 Geenius assays. Both HS and 903 performed well for up to 6 months at room temperature, but a marked loss of Western blot and low titer antibody signals from early infection samples was observed in samples stored for 180 days at elevated (37 to 45°C) temperatures and high humidity (95%). HemaSpot samples placed in sealed bags with additional desiccant were protected from degradation and showed improved signal recovery relative to that of the 903. HS was easier to use than the 903 and showed higher sensitivity and reproducibility for early infection samples and improved stability.
Assuntos
Teste em Amostras de Sangue Seco/instrumentação , Infecções por HIV/diagnóstico , HIV/isolamento & purificação , Manejo de Espécimes/instrumentação , Sorodiagnóstico da AIDS , HIV/imunologia , Anticorpos Anti-HIV/sangue , Anticorpos Anti-HIV/química , Antígenos HIV/sangue , Antígenos HIV/química , Infecções por HIV/sangue , Soropositividade para HIV/sangue , Humanos , Técnicas Imunoenzimáticas/normas , Estabilidade Proteica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Temperatura , Fatores de TempoRESUMO
Detection of acute HIV infection is critical for HIV public health and diagnostics. Clinical fourth-generation antigen (Ag)/antibody (Ab) combination (combo) and p24 Ag immunoassays have enhanced detection of acute infection compared to Ab-alone assays but require ongoing evaluation with currently circulating diverse subtypes. Genetically and geographically diverse HIV clinical isolates were used to assess clinical HIV diagnostic, blood screening, and next-generation assays. Three-hundred-member panels of 20 serially diluted well-characterized antibody-negative HIV isolates for which the researchers were blind to the results (blind panels) were distributed to manufacturers and end-user labs to assess the relative analytic sensitivity of currently approved and preapproved clinical HIV fourth-generation Ag/Ab combo or p24 Ag-alone immunoassays for the detection of diverse subtypes. The limits of detection (LODs) of virus were estimated for different subtypes relative to confirmed viral loads. Analysis of immunoassay sensitivity was benchmarked against confirmed viral load measurements on the blind panel. On the basis of the proportion of positive results on 300 observations, all Ag/Ab combo and standard sensitivity p24 Ag assays performed similarly and within half-log LODs, illustrating the similar breadth of reactivity and diagnostic utility. Ultrasensitive p24 Ag assays achieved dramatically increased sensitivities, while the rapid combo assays performed poorly. The similar performance of the different commercially available fourth-generation assays on diverse subtypes supports their use in broad geographic settings with locally circulating HIV clades and recombinant strains. Next-generation preclinical ultrasensitive p24 Ag assays achieved dramatically improved sensitivity, while rapid fourth-generation assays performed poorly for p24 Ag detection.
Assuntos
Sorodiagnóstico da AIDS/métodos , Sorodiagnóstico da AIDS/normas , Proteína do Núcleo p24 do HIV/sangue , Proteína do Núcleo p24 do HIV/imunologia , Infecções por HIV/diagnóstico , HIV/isolamento & purificação , Imunoensaio/normas , Carga Viral/normas , Benchmarking , HIV/imunologia , Anticorpos Anti-HIV/sangue , Antígenos HIV/sangue , Antígenos HIV/imunologia , Infecções por HIV/sangue , Humanos , Limite de Detecção , Sensibilidade e EspecificidadeRESUMO
The Hologic Aptima HIV-1 Qualitative RNA assay was used in a rigorous screening approach designed to identify individuals at the earliest stage of HIV-1 infection for enrollment into subsequent studies of cellular and viral events in early infection (RV 217/Early Capture HIV Cohort [ECHO] study). Volunteers at high risk for HIV-1 infection were recruited from study sites in Thailand, Tanzania, Uganda, and Kenya with high HIV-1 prevalence rates among the populations examined. Small-volume blood samples were collected by finger stick at twice-weekly intervals and tested with the Aptima assay. Participants with reactive Aptima test results were contacted immediately for entry into a more comprehensive follow-up schedule with frequent blood draws. Evaluation of the Aptima test prior to use in this study showed a detection sensitivity of 5.5 copies/ml (50%), with all major HIV-1 subtypes detected. A total of 54,306 specimens from 1,112 volunteers were examined during the initial study period (August 2009 to November 2010); 27 individuals were identified as converting from uninfected to infected status. A sporadic reactive Aptima signal was observed in HIV-1-infected individuals under antiretroviral therapy. Occasional false-reactive Aptima results in uninfected individuals, or nonreactive results in HIV-1-infected individuals not on therapy, were observed and used to calculate assay sensitivity and specificity. The sensitivity and specificity of the Aptima assay were 99.03% and 99.23%, respectively; positive and negative predictive values were 92.01% and 99.91%, respectively. Conversion from HIV-1-uninfected to -infected status was rapid, with no evidence of a prolonged period of intermittent low-level viremia.
Assuntos
Infecções por HIV/diagnóstico , HIV-1/isolamento & purificação , Técnicas de Diagnóstico Molecular/métodos , RNA Viral/sangue , África , Diagnóstico Precoce , HIV-1/genética , Humanos , Valor Preditivo dos Testes , RNA Viral/genética , Sensibilidade e Especificidade , TailândiaRESUMO
Quantitation of the HIV-1 viral load in plasma is the current standard of care for clinical monitoring of HIV-infected individuals undergoing antiretroviral therapy. This study evaluated the analytical and clinical performances of the Aptima HIV-1 Quant Dx assay (Hologic, San Diego, CA) for monitoring viral load by using 277 well-characterized subtype samples, including 171 cultured virus isolates and 106 plasma samples from 35 countries, representing all major HIV subtypes, recombinants, and circulating recombinant forms (CRFs) currently in circulation worldwide. Linearity of the Aptima assay was tested on each of 6 major HIV-1 subtypes (A, B, C, D, CRF01_AE, and CRF02_AG) and demonstrated an R(2) value of ≥0.996. The performance of the Aptima assay was also compared to those of the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 v.2 (CAP/CTM) and Abbott m2000 RealTime HIV-1 (RealTime) assays on all subtype samples. The Aptima assay values averaged 0.21 log higher than the CAP/CTM values and 0.30 log higher than the RealTime values, and the values were >0.4 log higher than CAP/CTM values for subtypes F and G and than RealTime values for subtypes C, F, and G and CRF02_AG. Two samples demonstrated results with >1-log differences from RealTime results. When the data were adjusted by the average difference, 94.9% and 87.0% of Aptima results fell within 0.5 log of the CAP/CTM and RealTime results, respectively. The linearity and accuracy of the Aptima assay in correctly quantitating all major HIV-1 subtypes, coupled with the completely automated format and high throughput of the Panther system, make this system well suited for reliable measurement of viral load in the clinical laboratory.
Assuntos
Infecções por HIV/virologia , HIV/isolamento & purificação , Carga Viral/métodos , Genótipo , HIV/classificação , HIV/genética , Humanos , Técnicas de Diagnóstico Molecular/métodosRESUMO
The availability of reliable human immunodeficiency virus types 1 and 2 (HIV-1/2) rapid tests in resource-limited settings represents an important advancement in the accurate diagnosis of HIV infection and presents opportunities for implementation of effective prevention and treatment interventions among vulnerable populations. A study of the potential target populations for future HIV vaccine studies examined the prevalence of HIV infections at six selected sites in Nigeria and evaluated the use of two rapid diagnostic tests (RDTs) for HIV. The populations included market workers at sites adjacent to military installations and workers at highway settlements (truck stops) who may have a heightened risk of HIV exposure. Samples from 3,187 individuals who provided informed consent were tested in parallel using the Determine (DT) and Stat-Pak (SP) RDTs; discordant results were subjected to the Uni-Gold (UG) RDT as a tiebreaker. The results were compared to those of a third-generation enzyme immunoassay screen with confirmation of repeat reactive samples by HIV-1 Western blotting. One participant was HIV-2 infected, yielding positive results on both RDTs. Using the laboratory algorithm as a gold standard, we calculated sensitivities of 98.5% (confidence interval [CI], 97.1 to 99.8%) for DT and 98.1% (CI, 96.7 to 99.6%) for SP and specificities of 98.7% (CI, 98.3 -99.1%) for DT and 99.8% (CI, 99.6 to 100%) for SP. Similar results were obtained when the sites were stratified into those of higher HIV prevalence (9.4% to 22.8%) versus those of lower prevalence (3.2% to 7.3%). A parallel two-test algorithm requiring both DT and SP to be positive resulted in the highest sensitivity (98.1%; CI, 96.7 to 99.6%) and specificity (99.97%; CI, 99.9 to 100%) relative to those for the reference laboratory algorithm.
Assuntos
Testes Diagnósticos de Rotina/métodos , Infecções por HIV/diagnóstico , Infecções por HIV/epidemiologia , HIV-1/imunologia , HIV-2/imunologia , Imunoensaio/métodos , Vacinas contra a AIDS/uso terapêutico , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Anticorpos Anti-HIV , HIV-1/genética , HIV-2/genética , Humanos , Nigéria/epidemiologia , RNA Viral/análise , RNA Viral/genética , Sensibilidade e EspecificidadeRESUMO
BACKGROUND: Accurate quantitation of immune markers is crucial for ensuring reliable assessment of vaccine efficacy against infectious diseases. This study was designed to confirm standardised performance of SARS-CoV-2 assays used to evaluate COVID-19 vaccine candidates at the initial seven laboratories (in North America, Europe, and Asia) of the Coalition for Epidemic Preparedness Innovations (CEPI) Centralized Laboratory Network (CLN). METHODS: Three ELISAs (pre-spike protein, receptor binding domain, and nucleocapsid), a microneutralisation assay (MNA), a pseudotyped virus-based neutralisation assay (PNA), and an IFN-γ T-cell ELISpot assay were developed, validated or qualified, and transferred to participating laboratories. Immune responses were measured in ELISA laboratory units (ELU) for ELISA, 50% neuralisation dilution (ND50) for MNA, 50% neutralisation titre (NT50) for PNA, and spot-forming units for the ELISpot assay. Replicate assay results of well characterised panels and controls of blood samples from individuals with or without SARS-CoV-2 infection were evaluated by geometric mean ratios, standard deviation, linear regression, and Spearman correlation analysis for consistency, accuracy, and linearity of quantitative measurements across all laboratories. FINDINGS: High reproducibility of results across all laboratories was demonstrated, with interlaboratory precision of 4·1-7·7% coefficient of variation for all three ELISAs, 3·8-19·5% for PNA, and 17·1-24·1% for MNA, over a linear range of 11-30 760 ELU per mL for the three ELISAs, 14-7876 NT50 per mL for PNA, and 21-25 587 ND50 per mL for MNA. The MNA was also adapted for detection of neutralising antibodies against the major SARS-CoV-2 variants of concern. The results of PNA and MNA (r=0·864) and of ELISA and PNA (r=0·928) were highly correlated. The IFN-γ ELISpot interlaboratory variability was 15·9-49·9% coefficient of variation. Sensitivity and specificity were close to 100% for all assays. INTERPRETATION: The CEPI CLN provides accurate quantitation of anti-SARS-CoV-2 immune response across laboratories to allow direct comparisons of different vaccine formulations in different geographical areas. Lessons learned from this programme will serve as a model for faster responses to future pandemic threats and roll-out of effective vaccines. FUNDING: CEPI.
Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Laboratórios , Reprodutibilidade dos Testes , Anticorpos Antivirais , ImunidadeRESUMO
BACKGROUND: Emergency whole blood transfusion is a lifesaving procedure employed on modern battlefields. Rapid device tests (RDTs) are frequently used to mitigate transfusion-transmitted infection risks. STUDY DESIGN AND METHODS: A limited evaluation of the RDT formerly used on battlefields was performed using 50 donor plasma samples and commercially available panels. Five hepatitis C virus (HCV) RDTs with sufficient stated sensitivity and thermostability were assessed using 335 HCV-positive and 339 HCV-negative donor plasma samples, 54 seroconversion panel plasma samples, and 84 HCV-positive and 84 HCV-negative spiked whole blood under normal, hot, and cold storage conditions and normal and hot test conditions, plus an ease-of-use survey. RESULTS: BioRapid HCV test sensitivity on donor plasma was 84% (95% confidence interval [CI], 70.9%-92.8%). Using all positive plasma samples, OraQuick HCV sensitivity exceeded all comparators (99.4%, 95% CI, 98.0%-99.9%, p<0.05). Specificity was consistently high, led by OraQuick HCV at 99.7% (95% CI, 98.6%-100%), statistically superior only to Axiom HCV (p<0.05). Using seroconversion panels, only OraQuick HCV showed equivalent or earlier HCV detection compared to the gold standard. Using spiked whole blood, specificity was consistently high, and sensitivity ranged significantly from 34.5% (95% CI, 25.0%-45.1%) for CORE HCV to 98.8% (95% CI, 94.3%-99.9%) for OraQuick HCV. All comparator RDTs were significantly less sensitive than OraQuick HCV at one or more stress condition. CONCLUSION: This HCV RDT comparison identified significant sensitivity differences, particularly using whole blood under extreme storage and testing conditions. These data support OraQuick HCV superiority and illustrate the value of RDT evaluation under simulated field conditions.
Assuntos
Doadores de Sangue , Seleção do Doador/métodos , Serviços Médicos de Emergência , Anticorpos Anti-Hepatite C/sangue , Kit de Reagentes para Diagnóstico , Algoritmos , Doadores de Sangue/estatística & dados numéricos , Preservação de Sangue/métodos , Segurança do Sangue , Técnicas de Laboratório Clínico/instrumentação , Técnicas de Laboratório Clínico/métodos , Eficiência , Serviços Médicos de Emergência/métodos , Serviços Médicos de Emergência/normas , Hepatite C/sangue , Hepatite C/diagnóstico , Anticorpos Anti-Hepatite C/análise , Humanos , Kit de Reagentes para Diagnóstico/normas , Sensibilidade e Especificidade , Fatores de TempoRESUMO
BACKGROUND: The United States introduced human T-lymphotropic virus Type I (HTLV-I) screening of blood donors in 1988. The US military uses freshly collected blood products for life-threatening injuries when available stored blood components in theater have been exhausted or when these components are unsuccessful for resuscitation. These donors are screened after donation by the Department of Defense (DoD) retrospective testing program. All recipients of blood collected in combat are tested according to policy soon after and at 3, 6, and 12 months after transfusion. CASE REPORT: A 31-year-old US Army soldier tested positive for HTLV-I 44 days after receipt of emergency blood transfusions for severe improvised explosive device blast injuries. One donor's unit tested HTLV-I positive on the DoD-mandated retrospective testing. Both the donor and the recipient tested reactive with enzyme immunoassay and supplemental confirmation by HTLV-I Western blot. The donor and recipient reported no major risk factors for HTLV-I. Phylogenetic analysis of HTLV-I sequences indicated Cosmopolitan subtype, Subgroup B infections. Comparison of long terminal repeat and env sequences revealed molecular genetic linkage of the viruses from the donor and recipient. CONCLUSION: This case is the first report of transfusion transmission of HTLV-I in the US military during combat operations. The emergency fresh whole blood policy enabled both the donor and the recipient to be notified of their HTLV-I infection. While difficult in combat, predonation screening of potential emergency blood donors with Food and Drug Administration-mandated infectious disease testing as stated by the DoD Health Affairs policy should be the goal of every facility engaged with emergency blood collection in theater.
Assuntos
Infecções por HTLV-I/transmissão , Reação Transfusional , Adulto , Emergências , Vírus Linfotrópico T Tipo 1 Humano/classificação , Vírus Linfotrópico T Tipo 1 Humano/genética , Humanos , Masculino , Militares , FilogeniaRESUMO
There has been a surge in the emergence of HIV-1 drug resistance in Low and Middle-Income Countries (LMICs) due to poor drug-adherence and limited access to viral load testing, the current standard for treatment-monitoring. It is estimated that only 75% of people living with HIV (PLWH) worldwide have access to viral load testing. In LMICs, this figure is below 50%. In a recent WHO survey in mostly LMICs, 21 out of 30 countries surveyed found HIV-1 first-line pre-treatment drug resistance in over 10% of study participants. In the worst-affected regions, up to 68% of infants born to HIV-1 positive mothers were found to harbour first-line HIV-1 treatment resistance. This is a huge public health concern. Greater access to treatment-monitoring is required in LMICs if the UNAIDS "third 95" targets are to be achieved by 2030. Here, we review the current challenges of viral load testing and present the case for greater utilization of Laboratory-based assays that quantify intracellular HIV-1 RNA and/or DNA to provide broader worldwide access to HIV-1 surveillance, drug-resistance monitoring, and cure-research.
Assuntos
Fármacos Anti-HIV , Infecções por HIV , Soropositividade para HIV , HIV-1 , Lactente , Humanos , HIV-1/genética , Fármacos Anti-HIV/uso terapêutico , Infecções por HIV/tratamento farmacológico , Soropositividade para HIV/tratamento farmacológico , Carga ViralRESUMO
Management of Human Immunodeficiency Virus Type 2 (HIV-2) infections present unique challenges due to low viral titers, slow disease progression, and poor response to standard antiviral therapies. The need for a nucleic acid assay to detect and quantify HIV-2 virus has led to the development of a number of molecular-based assays for detection and/or quantification of HIV-2 viral RNA in plasma in order to provide laboratory evidence of HIV-2 infection and viral loads for use in treatment decisions. As HIV-2 is less pathogenic and transmissible than HIV-1 and has resistance to several of the antiretroviral drugs, delay of treatment is common. Cross sero-reactivity between HIV-1 and HIV-2 makes it difficult to distinguish between the two viruses based upon serological tests. As such we developed a quantitative reverse transcription PCR (qRT-PCR) assay targeting the 5' long terminal repeat of HIV-2 for detection and quantification of HIV-2 viral RNA in plasma to identify HIV-2 infection and for use in viral load monitoring. Serial dilutions of cultured HIV-2 virus demonstrated a wide dynamic range (10 to 100,000 copies/ml) with excellent reproducibility (standard deviation from 0.12-0.19), linearity (R2 = 0.9994), and a lower limit of detection at 79 copies/ml (NIH-Z). The assay is highly specific for HIV-2 Groups A and B and exhibits no cross reactivity to HIV-1, HBV or HCV. Precision of the assay was demonstrated for the High (Mean = 6.41; SD = 0.12) and Medium (Mean = 4.46; SD = 0.13) HIV-2 positive controls. Replicate testing of clinical specimens showed good reproducibility above 1,000 copies/ml, with higher variability under 1,000 copies/ml. Analysis of 220 plasma samples from HIV-2 infected West African individuals demonstrated significantly lower viral loads than those observed in HIV-1 infections, consistent with results of previous studies. Slightly more than seven percent of clinical samples (7.3%) demonstrated viral loads above 100,000 copies/ml, while 37.3% of samples were undetectable. The high sensitivity, specificity, precision, and linearity of the WRAIR qRT-PCR assay makes it well suited for detection and monitoring of HIV-2 RNA levels in plasma of infected individuals.
Assuntos
Infecções por HIV/diagnóstico , HIV-1/genética , HIV-2/genética , Laboratórios/normas , RNA Viral/genética , Reação em Cadeia da Polimerase em Tempo Real/métodos , Testes Sorológicos/normas , Estudos de Casos e Controles , Infecções por HIV/sangue , Infecções por HIV/virologia , HIV-1/isolamento & purificação , HIV-2/isolamento & purificação , Humanos , RNA Viral/sangue , Kit de Reagentes para Diagnóstico , Carga ViralRESUMO
Development of a globally effective HIV-1 vaccine will need to encompass Nigeria, one of the hardest hit areas, with an estimated 3.2 million people living with HIV. This cross-sectional Institutional Review Board (IRB) approved study was conducted in 2009-12 at four market sites and two highway settlements sites in Nigeria to identify and characterize populations at high risk for HIV; engage support of local stakeholders; and assess the level of interest in future vaccine studies. Demographic, HIV risk data were collected by structured interviewer-administered questionnaires. Blood samples were tested on site by HIV rapid diagnostic tests, followed by rigorous confirmatory testing, subtype evaluation and testing for HBV and HCV markers in a clinical reference laboratory. Of 3229 study participants, 326 were HIV infected as confirmed by Western Blot or RNA, with a HIV prevalence of 15.4%-23.9% at highway settlements and 3.1%-9.1% at market sites. There was no observable correlation of prevalence of HIV-1 (10.1%) with HBV (10.9%) or HCV (2.9%). Major HIV-1 subtypes included CRF02_AG (37.5%); G (27.5%); G/CRF02_AG (25.9%); and non-typeable (8.9%), with 0.3% HIV-2. Univariate analysis found age, gender, marital status, level of education, and sex under substance influence as significant risk factors for HIV (p<0.001). Educating and winning the trust of local community leadership ensured high level of participation (53.3-77.9%) and willingness to participate in future studies (95%). The high HIV prevalence and high risk of HIV infection at highway settlement and mammy markets make them well suited for targeting future vaccine trials in Nigeria.
Assuntos
Vacinas contra a AIDS/imunologia , Síndrome da Imunodeficiência Adquirida/imunologia , Infecções por HIV/imunologia , HIV-1/imunologia , Vacinas contra a AIDS/administração & dosagem , Síndrome da Imunodeficiência Adquirida/prevenção & controle , Síndrome da Imunodeficiência Adquirida/virologia , Adolescente , Adulto , Estudos Transversais , Feminino , Infecções por HIV/epidemiologia , Infecções por HIV/virologia , HIV-1/fisiologia , Hepatite B/epidemiologia , Hepatite C/epidemiologia , Interações Hospedeiro-Patógeno/efeitos dos fármacos , Interações Hospedeiro-Patógeno/imunologia , Humanos , Masculino , Pessoa de Meia-Idade , Nigéria/epidemiologia , Aceitação pelo Paciente de Cuidados de Saúde/estatística & dados numéricos , Prevalência , Fatores de Risco , Inquéritos e Questionários , Adulto JovemRESUMO
While abundant sequence information is available from human immunodeficiency virus type 1 (HIV-1) subtypes A, B, C and CRF01_AE for HIV-1 vaccine design, sequences from West Africa are less represented. We sought to augment our understanding of HIV-1 variants circulating in 6 Nigerian cities as a step to subsequent HIV-1 vaccine development.The G/CRF02_AG multi-region hybridization assay (MHA) was developed to differentiate subtype G, CRF02_AG and their recombinants from other subtypes based on 7 HIV-1 segments. Plasma from 224 HIV-1 infected volunteers enrolled in a cohort examining HIV-1 prevalence, risk factor, and subtype from Makurdi (30), Abuja (18), Enugu (11), Kaduna (12), Tafa (95), and Ojo/Lagos (58) was analyzed using MHA. HIV-1 genomes from 42 samples were sequenced to validate the MHA and fully explore the recombinant structure of G and CRF02_AG variants.The sensitivity and specificity of MHA varied between 73-100% and 90-100%, respectively. The subtype distribution as identified by MHA among 224 samples revealed 38% CRF02_AG, 28% G, and 26% G/CRF02_AG recombinants while 8% remained nontypeable strains. In envelope (env) gp120, 38.84% of the samples reacted to a G probe while 31.25% reacted to a CRF02 (subtype A) probe. Full genome characterization of 42 sequences revealed the complexity of Nigerian HIV-1 variants.CRF02_AG, subtype G, and their recombinants were the major circulating HIV-1 variants in 6 Nigerian cities. High proportions of samples reacted to a G probe in env gp120 confirms that subtype G infections are abundant and should be considered in strategies for global HIV-1 vaccine development.
Assuntos
Regulação Viral da Expressão Gênica , Infecções por HIV/genética , HIV-1/genética , Polimorfismo Genético , Estudos de Coortes , Feminino , Infecções por HIV/epidemiologia , Humanos , Masculino , Nigéria/epidemiologia , Filogenia , Reação em Cadeia da Polimerase em Tempo Real/métodos , Recombinação Genética , Estudos Retrospectivos , Análise de Sequência de DNARESUMO
The development and verification of HIV-2 assays depends in part on the availability of well-characterized samples, including those from reagent repositories. During the development of an HIV-2 RNA quantification assay, two HIV-2 viral isolates (CDC 301340 and CDC 301342) obtained from the NIAID AIDS Reagent and Reference Repository were not detected leading to an investigation. Two HIV-2 primers/probe sets of known performance in real-time viral RNA quantification assays, targeting different regions of the virus, also failed to generate RT-PCR products for these two isolates. These isolates were tested in the HIV-1 specific COBAS AmpliPrep/COBAS TaqMan HIV-1 Test v2.0 (Roche Molecular Diagnostics) and were quantified at high copy number. Other HIV-2 isolates tested were not amplified in the COBAS HIV-1 TaqMan assay. Furthermore, the discrepant isolates were highly reactive in an HIV-1 p24 antigen test while the other HIV-2 isolates showed very weak, if any, cross-reactivity with the HIV-1 p24 assay. Phylogenetic tree analysis of sequences from the protease-reverse transcriptase regions of the discrepant HIV-2 isolates mapped with HIV-1 Group M, Subtype CRF02_AG confirming these isolates were of HIV-1 origin and had been misclassified as HIV-2. The use of misclassified isolates in the verification of molecular and immunological assays can lead to misinterpretation of test results, misdirection of efforts into assay redesign and increased development costs. The results of this study were shared with the NIAID AIDS Reagent Program, leading to the reclassification of the two discrepant isolates as HIV-1.
Assuntos
HIV-1/genética , HIV-2/genética , Primers do DNA , Bases de Dados Genéticas , HIV-1/classificação , HIV-1/isolamento & purificação , HIV-2/classificação , HIV-2/isolamento & purificação , Humanos , National Institute of Allergy and Infectious Diseases (U.S.) , Técnicas de Amplificação de Ácido Nucleico , Filogenia , RNA Viral/genética , Estados UnidosRESUMO
The interferon-gamma enzyme-linked immunospot (IFN-γ ELISpot) assay has been developed and used as an end-point assay in clinical trials for infectious diseases and cancer to detect the magnitude of antigen-specific immune responses. The ability to compare data generated by different laboratories across organizations is pivotal to understand the relative potency of different therapeutic and vaccine strategies. We developed an external proficiency program for the IFN-γ ELISpot assay that evaluates laboratory performance based on five parameters: timeliness for data reporting; ability to handle cellular samples; detection of background (non-specific) responses; accuracy to consensus of the results; and precision of the measurements. Points are awarded for each criterion, and the sum of the points is used to determine a numeric and adjectival performance rating. Importantly, the evaluation of the accuracy to the consensus mean for the detection of antigen-specific responses using laboratory-specific procedures informs each laboratory and its sponsor on the degree of concordance of its results with those obtained by other laboratories. This study will ultimately provide the scientific community with information on how to organize and implement an external proficiency program to evaluate longitudinally the performance of the participating laboratories and, therefore, fulfill the requirements of the GCLP guidelines for laboratories performing end-point IFN-γ ELISpot assay for clinical trials.
Assuntos
Ensaios Clínicos como Assunto/normas , ELISPOT/normas , Testes de Liberação de Interferon-gama/normas , Laboratórios/normas , Ensaio de Proficiência Laboratorial/normas , Monitorização Imunológica/normas , Indicadores de Qualidade em Assistência à Saúde/normas , Consenso , Comportamento Cooperativo , Fidelidade a Diretrizes/normas , Humanos , Cooperação Internacional , Estudos Longitudinais , Variações Dependentes do Observador , Guias de Prática Clínica como Assunto/normas , Valor Preditivo dos Testes , Desenvolvimento de Programas , Avaliação de Programas e Projetos de Saúde , Controle de Qualidade , Reprodutibilidade dos Testes , Manejo de Espécimes/normas , Fatores de TempoRESUMO
The continued global spread and evolution of HIV diversity pose significant challenges to diagnostics and vaccine strategies. NIAID partnered with the FDA, WRAIR, academia, and industry to form a Viral Panel Working Group to design and prepare a panel of well-characterized current and diverse HIV isolates. Plasma samples that had screened positive for HIV infection and had evidence of recently acquired infection were donated by blood centers in North and South America, Europe, and Africa. A total of 80 plasma samples were tested by quantitative nucleic acid tests, p24 antigen, EIA, and Western blot to assign a Fiebig stage indicative of approximate time from initial infection. Evaluation of viral load using FDA-cleared assays showed excellent concordance when subtype B virus was tested, but lower correlations for subtype C. Plasma samples were cocultivated with phytohemagglutinin (PHA)-stimulated peripheral blood mononuclear cells (PBMCs) from normal donors to generate 30 viral isolates (50-80% success rate for samples with viral load >10,000 copies/ml), which were then expanded to 10(7)-10(9) virus copies per ml. Analysis of env sequences showed that sequences derived from cultured PBMCs were not distinguishable from those obtained from the original plasma. The pilot collection includes 30 isolates representing subtypes B, C, B/F, CRF04_cpx, and CRF02_AG. These studies will serve as a basis for the development of a comprehensive panel of highly characterized viral isolates that reflects the current dynamic and complex HIV epidemic, and will be made available through the External Quality Assurance Program Oversight Laboratory (EQAPOL).