1.
AJR Am J Roentgenol ; 207(4): 865-870, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27504683

RESUMO

OBJECTIVE: We report a morphine-modified hepatoiminodiacetic acid (HIDA) scanning protocol that uses 2 mg of morphine IV push at the bedside as a pretreatment. We compared this protocol with the original HIDA scanning protocol, which included delayed imaging for up to 4 hours without the use of morphine. Moreover, we contrast our results with the results of studies in the literature. MATERIALS AND METHODS: We retrospectively reviewed the charts of inpatients who underwent HIDA scanning for the diagnosis of acute cholecystitis between 2003 and 2013. The study group consisted of 374 HIDA studies of 365 patients who received 2 mg of morphine IV push at bedside and then underwent dynamic imaging for 1 hour using 222 MBq of 99mTc-mebrofenin. No delayed images were obtained. The control group consisted of 232 studies of 227 patients who underwent conventional HIDA scanning using our standard protocol with delayed imaging and without morphine. Either strict pathologic criteria or the results of a percutaneous gallbladder drainage procedure were used for the confirmation of acute cholecystitis. RESULTS: The true-negative rate in the study group was 77% and in the control group, 72%. The positive predictive value in the study group was 81% and in the control group, 45%. The negative predictive value in the study group was 98% and in the control group, 99%. The accuracy in the study group was 95% and in the control group, 84%. The sensitivity in the study group was 93% and in the control group, 93%. The specificity in the study group was 95% and in the control group, 83%. The differences in the true-negative rate, accuracy, specificity, and positive predictive value of the morphine-modified protocol used for the study group and the original protocol used for the control group were statistically significant (p < 0.0005). CONCLUSION: Pretreatment using 2 mg of IV morphine at bedside before radionuclide imaging is superior to routine HIDA scanning with only delayed images for the diagnosis of acute cholecystitis. The results of our pretreatment morphine-modified protocol are comparable to those reported in the literature for posttreatment morphine-augmented protocols.

2.
Emerg Med J ; 28(2): 98-101, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21068166

RESUMO

BACKGROUND: 'Mules' or body packers are people who transport illegal drugs by packet ingestion into the gastrointestinal tract. These people are otherwise healthy and their management should maintain minimal morbidity. In this study, experience with body packers is presented and an algorithm for conservative and surgical management is provided. METHODS: The clinical patient database for all body packer admissions at Mary Immaculate Hospital of the Caritas Health Care Inc. from 1993 to 2005 was interrogated. 56 patients (4.5%) required admission out of a total of 1250 subjects confirmed to be body packers and apprehended by United State Customs officials at JFK International Airport, New York. The retrieved patient data were analysed retrospectively. RESULTS: 70% of the body packers were men, with a male to female ratio of 2.8 to 1. The mean age was 33 years and 52% were from Columbia. Heroin was the most common illegally transported substance (73%). 25 patients (45%) required surgical intervention, whereas 31 patients (55%) were successfully managed conservatively. Indications for intervention included: bowel obstruction, packet rupture/toxicity, and delayed progression of packet transit on conservative management. Multiple intraoperative manoeuvres were used to remove the foreign bodies: gastrotomy, enterotomy and colotomy. Wound infection was the most common complication and is associated with distal enterotomy and colotomy. CONCLUSIONS: Men were more likely to present as body packers than women. Proximal enterotomies are preferred and multiple enterotomies should be avoided. A confirmatory radiological study is needed to demonstrate complete clearance of packets. A systematic protocol for the management of body packers results in minimal morbidity and no mortality.


Assuntos
Crime , Embalagem de Medicamentos , Corpos Estranhos/diagnóstico , Corpos Estranhos/terapia , Drogas Ilícitas , Meios de Transporte , Adolescente , Adulto , Algoritmos , Protocolos Clínicos , Cocaína/efeitos adversos , Feminino , Corpos Estranhos/etiologia , Heroína/efeitos adversos , Humanos , Drogas Ilícitas/efeitos adversos , Masculino , Estudos Retrospectivos , Adulto Jovem
3.
J Surg Case Rep ; 2020(9): rjaa335, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33024532

RESUMO

Intussusception occurs when one portion of bowel 'telescopes' into another due to a lead point created by a range of benign or pathologic process. Intussusception mostly occurs in children. Although adult intussusception (AI) is rare, accounting for <5% of intestinal obstructions, it is more concerning in adults as malignancy accounts for nearly 65% of lead points in AI. Patients present with severe abdominal pain concerning for an acute abdomen along with a degree of bowel obstruction. We have experienced a total of 11 patients within recent years presenting with symptoms of an acute abdomen due to AI. None of these patients were found to have a pathologic process creating a lead point. However, we found that all of them were marijuana users. In this report, we compare their management, hospital course and review of the literature discussing proposed mechanisms that suggest an association between cannabis and intussusception.

5.
Gland Surg ; 3(3): 211-4, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25207215

RESUMO

Primary hyperparathyroidism is most commonly diagnosed in the setting of benign parathyroid adenoma(s). However, it can also rarely be caused by parathyroid malignancy and when it is, the clinical manifestations far supercede the presentation of benign parathyroid adenoma. We report a case of suspected benign parathyroid adenoma induced primary hyperparathyroidism in which pathologic diagnosis of parathyroid carcinoma was made. Due to the lack of signs and symptoms, this indicates parathyroid malignancy can be masked clinically as benign adenomas, until a histologic diagnosis can be ascertained.

6.
J Biomed Mater Res B Appl Biomater ; 102(5): 1093-100, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24327401

RESUMO

Approximately 400,000 ventral hernia repair surgeries are performed each year in the United States. Many of these procedures are performed using laparoscopic minimally invasive techniques and employ the use of surgical mesh. The use of surgical mesh has been shown to reduce recurrence rates compared to standard suture repairs. The placement of surgical mesh in a ventral hernia repair procedure can be challenging, and may even complicate the procedure. Others have attempted to provide commercial solutions to the problems of mesh placement, but these have not been well accepted by the clinical community. In this article, two versions of shape memory polymer (SMP)-modified surgical mesh, and unmodified surgical mesh, were compared by performing laparoscopic manipulation in an acute porcine model. Also, SMP-integrated polyester surgical meshes were implanted in four rats for 30-33 days to evaluate chronic biocompatibility and capacity for tissue integration. Porcine results show that the modified mesh provides a controlled, temperature-activated, automated deployment when compared to an unmodified mesh. In rats, results indicate that implanted SMP-modified meshes exhibit exceptional biocompatibility and excellent integration with surrounding tissue with no noticeable differences from the unmodified counterpart. This article provides further evidence that an SMP-modified surgical mesh promises reduction in surgical placement time and that such a mesh is not substantially different from unmodified meshes in chronic biocompatibility.


Assuntos
Hérnia Ventral/cirurgia , Laparoscopia , Teste de Materiais , Poliésteres , Telas Cirúrgicas , Animais , Feminino , Hérnia Ventral/patologia , Ratos , Ratos Sprague-Dawley
7.
J Biomed Mater Res A ; 101(9): 2613-20, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23412974

RESUMO

About 600,000 hernia repair surgeries are performed each year; recently, the use of laparoscopic minimally invasive techniques has become increasingly popular in these operations. Use of surgical mesh in hernia repair has shown lower recurrence rates compared to other repair methods. However in many procedures, placement of surgical mesh can be challenging and even complicate the procedure, potentially leading to lengthy operating times. Various techniques have been attempted to improve mesh placement, including use of specialized systems to orient the mesh into a specific shape, with limited success and acceptance. In this study, a programmed novel Shape Memory Polymer (SMP) was integrated into commercially available polyester surgical meshes to add automatic unrolling and tissue conforming functionalities, while preserving the intrinsic structural properties of the original surgical mesh. Tensile testing and Dynamic Mechanical Analysis was performed on four different SMP formulas to identify appropriate mechanical properties for surgical mesh integration. In vitro testing involved monitoring the time required for a modified surgical mesh to deploy in a 37°C water bath. An acute porcine model was used to test the in vivo unrolling of SMP integrated surgical meshes. The SMP-integrated surgical meshes produced an automated, temperature activated, controlled deployment of surgical mesh on the order of several seconds, via laparoscopy in the animal model. Results indicate surgical mesh modified with SMP is capable of laparoscopic deployment in vivo, activated by body temperature. This suggests a reduction in surgical operating time and improved mesh placement characteristics is possible with SMP-integrated surgical meshes.


Assuntos
Materiais Biocompatíveis/química , Laparoscopia/métodos , Polímeros/química , Telas Cirúrgicas , Animais , Fenômenos Biomecânicos , Feminino , Herniorrafia/métodos , Humanos , Teste de Materiais , Modelos Animais , Suínos , Resistência à Tração , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS