Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Opt Mater (Amst) ; 80: 197-202, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30692715

RESUMO

Radiation therapy is one of the primary therapeutic techniques for treating cancer, administered to nearly two-thirds of all cancer patients. Although largely effective in killing cancer cells, radiation therapy, like other forms of cancer treatment, has difficulty dealing with hypoxic regions within solid tumors. The incomplete killing of cancer cells can lead to recurrence and relapse. The research presented here is investigating the enhancement of the efficacy of radiation therapy by using scintillating nanoparticles that emit UV photons. UV photons, with wavelengths between 230 nm and 280 nm, are able to inactivate cells due to their direct interaction with DNA, causing a variety of forms of damage. UV-emitting nanoparticles will enhance the treatment in two ways: first by generating UV photons in the immediate vicinity of cancer cells, leading to direct and oxygen-independent DNA damage, and second by down-converting the applied higher energy X-rays into softer X-rays and particles that are more efficiently absorbed in the targeted tumor region. The end result will be nanoparticles with a higher efficacy in the treatment of hypoxic cells in the tumor, filling an important, unmet clinical need. Our preliminary experiments show an increase in cell death using scintillating LuPO4:Pr nanoparticles over that achieved by the primary radiation alone. This work describes the fabrication of the nanoparticles, their physical characterization, and the spectroscopic characterization of the UV emission. The work also presents in vitro results that demonstrate an enhanced efficacy of cell killing with x-rays and a low unspecific toxicity of the nanoparticles.

2.
Artigo em Inglês | MEDLINE | ID: mdl-29706680

RESUMO

In reconstructive surgery, tissue perfusion/vessel patency is critical to the success of microvascular free tissue flaps. Early detection of flap failure secondary to compromise of vascular perfusion would significantly increase the chances of flap salvage. We have developed a compact, clinically-compatible monitoring system to enable automated, minimally-invasive, continuous, and quantitative assessment of flap viability/perfusion. We tested the system's continuous monitoring capability during extended non-recovery surgery using an in vivo porcine free flap model. Initial results indicated that the system could assess flap viability/perfusion in a quantitative and continuous manner. With proven performance, the compact form constructed with cost-effective components would make this system suitable for clinical translation.

3.
Artigo em Inglês | MEDLINE | ID: mdl-29706683

RESUMO

In reconstructive surgery, impeded blood flow in microvascular free flaps due to a compromise in arterial or venous patency secondary to blood clots or vessel spasms can rapidly result in flap failures. Thus, the ability to detect changes in microvascular free flaps is critical. In this paper, we report progress on in vivo pre-clinical testing of a compact, multimodal, fiber-based diffuse correlation and reflectance spectroscopy system designed to quantitatively monitor tissue perfusion in a porcine model's surgically-grafted free flap. We also describe the device's sensitivity to incremental blood flow changes and discuss the prospects for continuous perfusion monitoring in future clinical translational studies.

4.
Artigo em Inglês | MEDLINE | ID: mdl-29755163

RESUMO

It is essential to monitor tissue perfusion during and after reconstructive surgery, as restricted blood flow can result in graft failures. Current clinical procedures are insufficient to monitor tissue perfusion, as they are intermittent and often subjective. To address this unmet clinical need, a compact, low-cost, multimodal diffuse correlation spectroscopy and diffuse reflectance spectroscopy system was developed. We verified system performance via tissue phantoms and experimental protocols for rigorous bench testing. Quantitative data analysis methods were employed and tested to enable the extraction of tissue perfusion parameters. This design verification study assures data integrity in future in vivo studies.

5.
J Biomed Opt ; 22(12): 1-14, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29243415

RESUMO

In reconstructive surgery, the ability to detect blood flow interruptions to grafted tissue represents a critical step in preventing postsurgical complications. We have developed and pilot tested a compact, fiber-based device that combines two complimentary modalities-diffuse correlation spectroscopy (DCS) and diffuse reflectance spectroscopy-to quantitatively monitor blood perfusion. We present a proof-of-concept study on an in vivo porcine model (n=8). With a controllable arterial blood flow supply, occlusion studies (n=4) were performed on surgically isolated free flaps while the device simultaneously monitored blood flow through the supplying artery as well as flap perfusion from three orientations: the distal side of the flap and two transdermal channels. Further studies featuring long-term monitoring, arterial failure simulations, and venous failure simulations were performed on flaps that had undergone an anastomosis procedure (n=4). Additionally, benchtop verification of the DCS system was performed on liquid flow phantoms. Data revealed relationships between diffuse optical measures and state of occlusion as well as the ability to detect arterial and venous compromise. The compact construction of the device, along with its noninvasive and quantitative nature, would make this technology suitable for clinical translation.


Assuntos
Retalhos de Tecido Biológico/irrigação sanguínea , Monitorização Hemodinâmica/instrumentação , Dispositivos Ópticos , Anastomose Cirúrgica , Animais , Artérias/diagnóstico por imagem , Artérias/patologia , Suínos , Veias/diagnóstico por imagem , Veias/patologia
6.
Artigo em Inglês | MEDLINE | ID: mdl-29056812

RESUMO

Currently the diagnosis of hemorrhagic shock is essentially clinical, relying on the expertise of nurses and doctors. One of the first measurable physiological changes that marks the onset of hemorrhagic shock is a decrease in capillary blood flow. Diffuse correlation spectroscopy (DCS) quantifies this decrease. DCS collects and analyzes multiply scattered, coherent, near infrared light to assess relative blood flow. This work presents a preliminary study using a DCS instrument with human subjects undergoing a lower body negative pressure (LBNP) protocol. This work builds on previous successful DCS instrumentation development and we believe it represents progress toward understanding how DCS can be used in a clinical setting.

7.
Artigo em Inglês | MEDLINE | ID: mdl-29706686

RESUMO

The vascularization and resulting perfusion of transferred tissues are critical to the success of grafts in buried free flap transplantations. To enable long-term clinical monitoring of grafted tissue perfusion during neovascularization and endothelialization, we are developing an implantable instrument for the continuous monitoring of perfusion using diffuse correlation spectroscopy (DCS), and augmented with diffuse reflectance spectroscopy (DRS). This work discusses instrument construction, integration, and preliminary results using a porcine graft model.

8.
Artigo em Inglês | MEDLINE | ID: mdl-29056813

RESUMO

Stable, relative localization of source and detection fibers is necessary for clinical implementation of quantitative optical perfusion monitoring methods such as diffuse correlation spectroscopy (DCS) and diffuse reflectance spectroscopy (DRS). A flexible and compact device design is presented as a platform for simultaneous monitoring of perfusion at a range of depths, enabled by precise location of optical fibers in a robust and secure adhesive patch. We will discuss preliminary data collected on human subjects in a lower body negative pressure model for hypovolemic shock. These data indicate that this method facilitates simple and stable simultaneous monitoring of perfusion at multiple depths and within multiple physiological compartments.

9.
Colloids Surf B Biointerfaces ; 103: 59-66, 2013 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-23201720

RESUMO

Solute self-organization during evaporation of colloidal sessile droplets has attracted the attention of researchers over the past few decades due to a variety of technological applications. Recently, pattern formation during evaporation of various biofluids has been studied due to potential applications in screening and diagnosis. The complex morphological patterns in the deposit are unique to various disorders and are influenced by various physical mechanisms occurring during evaporation. These complex patterns can be better understood by studying evaporation of model solutions of biological relevance. Here, we examine the general features of pattern formation during sessile droplet evaporation of aqueous lysozyme solutions with varying concentrations of NaCl. Lysozyme is a globular protein found in biological fluids such as tears and saliva. The morphological evolution of the droplet is studied by time-lapse video during evaporation via reflection optical microscopy. The final deposits exhibit an amorphous peripheral ring and interior regions containing crystallites and dendritic forms, dependent on NaCl concentration. Scanning electron microscopy (SEM) images demonstrate the multi-scale hierarchical nature of these structures.


Assuntos
Muramidase/química , Cloreto de Sódio/química , Cloretos/química , Humanos , Muramidase/ultraestrutura , Sódio/química , Soluções , Volatilização
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA