Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Eur Spine J ; 31(9): 2255-2261, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35590015

RESUMO

PURPOSE: Prone transpsoas fusion (PTP) is a minimally invasive technique that maximizes the benefit of lateral access interbody surgery and the prone positioning for surgically significant adjacent segment disease. The authors describe the feasibility, reproducibility and radiographic efficacy of PTP when performed for cases of lumbar ASD. METHODS: Adult patients undergoing PTP for treatment of lumbar ASD at three institutions were retrospectively enrolled. Demographic information was recorded, as was operative data such as adjacent segment levels, operative time, blood loss, laterality of approach, open versus percutaneous pedicle screw instrumentation and need for primary decompression. Radiographic measurements including segmental and global lumbar lordosis, pelvic incidence, pelvic tilt, sacral slope and sagittal vertical axis were recorded both pre- and immediately post-operatively. RESULTS: Twenty-four patients met criteria for inclusion. Average age was 60.4 ± 10.4 years and average BMI was 31.6 ± 5.0 kg/m2. Total operative time was 204.7 ± 83.3 min with blood loss of 187.9 ± 211 mL. Twenty-one patients had pedicle screw instrumentation exchanged percutaneously and 3 patients had open pedicle screw exchange. Two patients suffered pulmonary embolism that was treated medically with no long-term sequelae. One patient had transient lumbar radicular pain and all patients were discharged home with an average length of stay of 3.0 days (range 1-6). Radiographically, global lumbar lordosis improved by an average of 10.3 ± 9.0 degrees, segmental lordosis by 10.1 ± 13.3 degrees and sagittal vertical axis by 3.2 ± 3.2 cm. CONCLUSION: Single-position prone transpsoas lumbar interbody fusion is a clinically reproducible minimally invasive technique that can effectively treat lumbar adjacent segment disease.


Assuntos
Lordose , Fusão Vertebral , Adulto , Idoso , Humanos , Lordose/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fusão Vertebral/métodos , Resultado do Tratamento
2.
Neurosurg Rev ; 44(4): 1933-1941, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33025187

RESUMO

Unruptured intracranial saccular aneurysms occur in 3-5% of the general population. As the use of diagnostic medical imaging has steadily increased over the past few decades with the increased availability of computed tomography (CT) and magnetic resonance imaging (MRI), so has the detection of incidental aneurysms. The management of an unruptured intracranial saccular aneurysm is challenging for both patients and physicians, as the decision to intervene must weigh the risk of rupture and resultant subarachnoid hemorrhage against the risk inherent to the surgical or endovascular procedure. The purpose of this paper is to provide an overview of factors to be considered in the decision to offer treatment for unruptured intracranial aneurysms in adults. In addition, we review aneurysm and patient characteristics that favor surgical clipping over endovascular intervention and vice versa. Finally, the authors propose a novel, simple, and clinically relevant algorithm for observation versus intervention in unruptured intracranial aneurysms based on the PHASES scoring system.


Assuntos
Aneurisma Roto , Procedimentos Endovasculares , Aneurisma Intracraniano , Hemorragia Subaracnóidea , Adulto , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Imageamento por Ressonância Magnética , Hemorragia Subaracnóidea/diagnóstico por imagem , Hemorragia Subaracnóidea/cirurgia
3.
Acta Neurochir (Wien) ; 163(11): 2983-2990, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34129101

RESUMO

BACKGROUND: Robotic-assisted surgery is becoming more widely applied in surgical subspecialties due to its intraoperative and postoperative advantages such as minimally invasive approach, reduced blood loss, shorter hospital stay, and decreased incidence of postoperative complications. However, robotic devices were only recently introduced in the field of spinal surgery. Specifically, percutaneous approaches involving computer-assisted image guidance are relatively new in iliac screw fixation. Previous methods focused on the use of S2-alar-iliac (S2AI) screw fixation which allows for pelvic fixation without a need for side connectors. However, for patients with destructive lesions of the sacrum, placement of these S2AI screws may not be feasible. The purpose of this technical note is to illustrate the implementation of robotic-assisted percutaneous iliac screw fixation in two cases which allows for minimally invasive attachment to the proximal lumbar screws without a side connector and eliminates a potential source of instrumentation failure. METHODS: Robotic-assisted percutaneous iliac screw fixation was performed on two patients. The robotics system was used to merge the fluoroscopic images with intraoperative computed tomography (CT) images to plan the trajectories for placement of bilateral pedicle and iliac screws. Intraoperative CT scan was again performed to confirm proper placement of all screws. Rods were then engaged bilaterally with the pedicle and iliac screws without the use of side connectors. RESULTS: The patients did not experience immediate postoperative complications and had stable hardware at one-month follow-up. Our cases demonstrate the surgical efficiency of robotic-assisted lumbo-iliac instrumentation which obviates the need to use a side connector, which is commonly used in iliac fixation. This eliminates a step, which can reduce the possibility of instrumentation failure. CONCLUSION: Robotic-assisted percutaneous iliac screw fixation is a safe and feasible technique to improve operative and clinical outcomes in complex spinal instrumentation surgeries.


Assuntos
Procedimentos Cirúrgicos Robóticos , Fusão Vertebral , Parafusos Ósseos , Humanos , Ílio/diagnóstico por imagem , Ílio/cirurgia , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Sacro/diagnóstico por imagem , Sacro/cirurgia
4.
Neurosurg Focus ; 49(5): E20, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33130620

RESUMO

Spine surgery has been disproportionately impacted by medical liability and malpractice litigation, with the majority of claims and payouts related to procedural error. One common area for the potential avoidance of malpractice claims and subsequent payouts involves misplaced pedicle and/or lateral mass instrumentation. However, the medicolegal impact of misplaced screws on spine surgery has not been directly reported in the literature. The authors of the current study aimed to describe this impact in the United States, as well as to suggest a potential method for mitigating the problem.This retrospective analysis of 68 closed medicolegal cases related to misplaced screws in spine surgery showed that neurosurgeons and orthopedic spine surgeons were equally named as the defendant (n = 32 and 31, respectively), and cases were most commonly due to misplaced lumbar pedicle screws (n = 41, 60.3%). Litigation resulted in average payouts of $1,204,422 ± $753,832 between 1995 and 2019, when adjusted for inflation. The median time to case closure was 56.3 (35.2-67.2) months when ruled in favor of the plaintiff (i.e., patient) compared to 61.5 (51.4-77.2) months for defendant (surgeon) verdicts (p = 0.117).


Assuntos
Imperícia , Parafusos Pediculares , Cirurgiões , Humanos , Neurocirurgiões , Estudos Retrospectivos , Coluna Vertebral , Estados Unidos
5.
AJR Am J Roentgenol ; 213(3): 651-658, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31063421

RESUMO

OBJECTIVE. Compared with open procedures, minimally invasive surgical procedures are associated with increased radiation exposure and long-term health risks. Ultralow radiation imaging coupled with image enhancement and instrument tracking (ULRI-IE/IT) is a new image modifier that allows a computer to show real-time movement of an instrument as it is adjusted, mimicking live fluoroscopy but without continuous radiation production. The purpose of this study was to determine the accuracy and radiation output of ULRI-IE/IT compared with unassisted conventional fluoroscopy in a variety of surgical procedures. MATERIALS AND METHODS. Physicians of various specialties were asked to identify the ideal location for instrumentation in various spinal, orthopedic, pain, and physiatric procedures and then place an instrument in this location in a cadaver both with and without ULRI-IE/IT assistance. Whether ULRI-IE/IT was used was randomly assigned to reduce the impact of learning. Radiation exposure, time to place the instrument, and the number of images required to achieve accurate positioning were recorded for each procedure. These were compared for unassisted and ULRI-IE/IT-assisted fluoroscopy to determine the utility of ULRI-IE/IT in minimally invasive instrumentation. RESULTS. Twenty-three trials of nine procedures by five physicians were completed both with and without assistance of ULRI-IE/IT. The procedures ranged from percutaneous pedicle screw insertion to foramen ovale ablation. Total time to localize the instrument for all 23 cases was 31.2% longer without assistance. Use of ULRI-IE/IT reduced the total number of images per case by 74.8% and radiation exposure by 91.8%. With ULRI-IE/IT, physicians were able to successfully place the instrument in the correct location on the first attempt in 82.6% of trials and in the second attempt in all trials versus a mean of 4.65 images needed for unassisted fluoroscopy. CONCLUSION. Use of ULRI-IE/IT can dramatically reduce radiation output and the number of images acquired and time required to perform fluoroscopic procedures.


Assuntos
Fluoroscopia/instrumentação , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Duração da Cirurgia , Exposição à Radiação , Radiografia Intervencionista/instrumentação , Cirurgia Assistida por Computador/métodos , Cadáver , Humanos , Posicionamento do Paciente
6.
Circulation ; 132(11): 1003-12, 2015 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-26179404

RESUMO

BACKGROUND: Although disturbed flow is thought to play a central role in the development of advanced coronary atherosclerotic plaques, no causal relationship has been established. We evaluated whether inducing disturbed flow would cause the development of advanced coronary plaques, including thin cap fibroatheroma. METHODS AND RESULTS: D374Y-PCSK9 hypercholesterolemic minipigs (n=5) were instrumented with an intracoronary shear-modifying stent (SMS). Frequency-domain optical coherence tomography was obtained at baseline, immediately poststent, 19 weeks, and 34 weeks, and used to compute shear stress metrics of disturbed flow. At 34 weeks, plaque type was assessed within serially collected histological sections and coregistered to the distribution of each shear metric. The SMS caused a flow-limiting stenosis, and blood flow exiting the SMS caused regions of increased shear stress on the outer curvature and large regions of low and multidirectional shear stress on the inner curvature of the vessel. As a result, plaque burden was ≈3-fold higher downstream of the SMS than both upstream of the SMS and in the control artery (P<0.001). Advanced plaques were also primarily observed downstream of the SMS, in locations initially exposed to both low (P<0.002) and multidirectional (P<0.002) shear stress. Thin cap fibroatheroma regions demonstrated significantly lower shear stress that persisted over the duration of the study in comparison with other plaque types (P<0.005). CONCLUSIONS: These data support a causal role for lowered and multidirectional shear stress in the initiation of advanced coronary atherosclerotic plaques. Persistently lowered shear stress appears to be the principal flow disturbance needed for the formation of thin cap fibroatheroma.


Assuntos
Aterosclerose/etiologia , Aterosclerose/fisiopatologia , Vasos Coronários/fisiopatologia , Hipercolesterolemia/complicações , Placa Aterosclerótica/etiologia , Placa Aterosclerótica/fisiopatologia , Fluxo Sanguíneo Regional/fisiologia , Animais , Animais Geneticamente Modificados , Angiografia Coronária , Circulação Coronária/fisiologia , Modelos Animais de Doenças , Hemodinâmica/fisiologia , Hipercolesterolemia/genética , Hipercolesterolemia/fisiopatologia , Pró-Proteína Convertases/genética , Resistência ao Cisalhamento/fisiologia , Stents , Estresse Mecânico , Suínos , Porco Miniatura , Fatores de Tempo , Tomografia de Coerência Óptica
7.
Arterioscler Thromb Vasc Biol ; 34(10): 2224-31, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25060797

RESUMO

In this review, we summarized the effect of mechanical factors (shear and wall stress) on thin-cap fibroatheroma formation and rupture. To make this review understandable for a biology-oriented audience, we start with detailed definitions of relevant mechanical metrics. We then describe how biomechanics has supported histopathologic efforts to understand the basis of plaque rupture. In addition to plaque rupture, biomechanics also contributes toward the progression of thin-cap fibroatheroma through a multitude of reported mechanobiological mechanisms. We thus propose a new mechanism whereby both shear stress and wall stress interact to create thin-cap fibroatheromas. Specifically, when regions of certain blood flow and wall mechanical stimuli coincide, they synergistically create inflammation within the cellular environment that can lead to thin-cap fibroatheroma rupture. A consequence of this postulate is that local shear stress is not sufficient to cause rupture, but it must coincide with regions of local tissue stiffening and stress concentrations that can occur during plaque progression. Because such changes to the wall mechanics occur over a micrometer scale, high spatial resolution imaging techniques will be necessary to evaluate this hypothesis and ultimately predict plaque rupture in a clinical environment.


Assuntos
Artérias/patologia , Aterosclerose/patologia , Mecanotransdução Celular , Placa Aterosclerótica , Animais , Artérias/metabolismo , Artérias/fisiopatologia , Aterosclerose/complicações , Aterosclerose/metabolismo , Aterosclerose/fisiopatologia , Fenômenos Biomecânicos , Progressão da Doença , Fibrose , Humanos , Fluxo Sanguíneo Regional , Fatores de Risco , Ruptura Espontânea , Estresse Mecânico
8.
Ophthalmic Physiol Opt ; 35(1): 52-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25424300

RESUMO

PURPOSE: Refractive changes in diabetic eyes have long been reported but with equivocal results. The lens has been a more recent focus as the source of any change but it is possible that multiple sources of variation have made it difficult to demonstrate a systematic change clinically. The aim of this study was therefore to use a bovine lens model to investigate the optical changes in hyperglycaemia and when lenses are returned to normal glucose levels as would occur following commencement of treatment. METHOD: Bovine eyes were obtained and their lenses excised under sterile conditions before placing them in culture medium within an incubator using standard tissue culture techniques. In the first experiment, lenses were transferred into culture medium containing 5 mm (n = 12), 15 mm (n = 12) and 30 mm (n = 12) glucose. Measurements were made of the change in back vertex focusing distance with equatorial lens diameter using the ScanTox(™) measurement system. From these measurements, the back vertex focal length and primary longitudinal spherical aberration were derived. In a second experiment, lenses maintained at 30 mm glucose (n = 7) were stepped down to 5 mm glucose to simulate starting diabetic therapy and measured in the same way. Changes over time were assessed with a linear regression model. RESULTS: A trend towards myopia was observed with increasing hyperglycaemia, this was not statistically significant. When lenses were stepped-down from hyperglycaemia to normal physiological levels of glucose, a hyperopic shift was observed in line with published clinical studies that again failed to reach statistical significance. High variability in the measurement on longitudinal spherical aberration prevented any significant trends being measured. CONCLUSIONS: Our results suggest that there are no consistent crystalline lens-induced refractive changes following exposure to hyperglycaemia for time-periods up to 5 days used in the current study. It is possible that bovine lenses are able to offset the raised osmotic pressure from high glucose levels in the short-term by a process of osmoregulation and that repeated osmotic stress or longer term exposure may be required to induce the changes in refraction that are seen clinically.


Assuntos
Glucose/metabolismo , Hiperglicemia/complicações , Cristalino/metabolismo , Refração Ocular/fisiologia , Erros de Refração/metabolismo , Animais , Bovinos , Modelos Animais de Doenças , Erros de Refração/etiologia , Análise de Regressão , Reprodutibilidade dos Testes
9.
World Neurosurg X ; 22: 100341, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38450248

RESUMO

Despite decreases in mortality rate, the treatment of cognitive deficits following aneurysmal subarachnoid hemorrhage (aSAH) remains a serious challenge for clinicians and survivors alike. Deficits in executive function, language, and memory prevent more than half of survivors from returning to their previous level of work and put a tremendous amount of stress on the individual and their family. New therapies are needed for survivors of aSAH in order to improve cognitive outcomes and quality of life. The aim of this review is to discuss the prevalence and contributing factors of cognitive deficits following aSAH, as well as areas for therapeutic intervention. Due to the limited research on cognitive rehabilitative strategies for aSAH, a literature search of traumatic brain injury (TBI) was used to explore therapies with the potential to improve cognitive outcomes in aSAH. Across cognitive domains, existing rehabilitative and pharmacotherapeutic strategies for TBI show promise to be useful for survivors of aSAH. However, further study of these therapies in addition to consistent assessment of cognitive deficits are required to determine their efficacy in survivors of aSAH.

10.
J Spine Surg ; 9(2): 201-208, 2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37435328

RESUMO

Background: Enterothecal fistulas are pathological connections between the gastrointestinal system and subarachnoid space. These rare fistulas occur mostly in pediatric patients with sacral developmental anomalies. They have yet to be characterized in an adult born without congenital developmental anomaly yet must remain on the differential diagnosis when all other causes of meningitis and pneumocephalus have been ruled out. Good outcomes rely on aggressive multidisciplinary medical and surgical care, which are reviewed in this manuscript. Case Description: A 25-year-old female with history of a sacral giant cell tumor resected via anterior transperitoneal approach followed by posterior L4-pelvis fusion presented with headaches and altered mental status. Imaging revealed that a portion of small bowel had migrated into her resection cavity and created an enterothecal fistula resulting in fecalith within the subarachnoid space and florid meningitis. The patient underwent a small bowel resection for fistula obliteration, and subsequently developed hydrocephalus requiring shunt placement and two suboccipital craniectomies for foramen magnum crowding. Ultimately, her wounds became infected requiring washouts and instrumentation removal. Despite a prolonged hospital course, she made significant recovery and at 10-month following presentation, she is awake, oriented, and able to participate in activities of daily living. Conclusions: This is the first case of meningitis secondary to enterothecal fistula in a patient without a previous congenital sacral anomaly. Operative intervention for fistula obliteration is the primary treatment and should be performed at a tertiary hospital with multidisciplinary capabilities. If recognized quickly and appropriately treated, there is a possibility of good neurological outcome.

11.
Int J Spine Surg ; 17(6): 760-770, 2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-37553259

RESUMO

BACKGROUND: There has been heightened interest in performing percutaneous lumbar interbody fusions (percLIFs) through Kambin's triangle, an anatomic corridor allowing entrance into the disc space. However, due to its novelty, there are limited data regarding the long-term benefits of this procedure. Our objective was to determine the long-term efficacy and durability of the percutaneous insertion of an expandable titanium cage through Kambin's triangle without facetectomy. METHODS: A retrospective review of patients undergoing percLIF via Kambin's triangle using an expandable titanium cage was performed. Demographics, visual analog scale (VAS) scores, Oswestry Disability Index (ODI), radiographic measurements, perioperative variables, and complications were recorded. VAS, ODI, and radiographic measurements were compared with baseline using the generalized estimating equations assuming normally distributed data. Fusion was assessed with computed tomography (CT) at 1 and 2 years after the procedure. RESULTS: A total of 49 patients were included. Spondylolisthesis, lumbar lordosis (LL), sacral slope, pelvic tilt, and anterior/posterior disc space height were all significantly improved postoperatively at each time point of 3, 6, 12, and 24 months (P < 0.001). Pelvic incidence-LL mismatch decreased significantly at each follow-up (P < 0.001) with a mean reduction of 4° by 24 months. VAS back scores reduced by >2 points at the 6, 12, and 24 month follow-ups. ODI scores reduced by >15 points at the 12- and 24-month follow-ups. Of the patients who had 1- and 2-year CT images, fusion rates at those time points were 94.4% (17/18) and 87.5% (7/8), respectively. The mean annual rate of surgically significant adjacent segment disease was 2.74% through an average follow-up of 2.74 years. CONCLUSION: These results highlight that percLIF, a procedure done without an endoscope or facetectomy, can be performed using an expandable titanium cage through Kambin's triangle with excellent radiographic and clinical results. CLINICAL RELEVANCE: percLIF via Kambin's triangle is a safe and succesful procedure with long-term improvements in both clinical and radiographic outcomes.

12.
World Neurosurg ; 2023 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-37355168

RESUMO

OBJECTIVE: While Kambin's Triangle has become an ever more important anatomic window given its proximity to the exiting nerve root, there have been limited studies examining the effect of disease on the corridor. Our goal was to better understand how pathology can affect Kambin's Triangle, thereby altering the laterality of approach for percutaneous lumbar interbody fusion (percLIF). METHODS: The authors performed a single-center retrospective review of patients evaluated for percLIF. The areas of Kambin's Triangle were measured without and with nerve segmentation. For the latter, the lumbosacral nerve roots on 3-dimensional T2 magnetic resonance imaging were manually segmented. Next, the borders of Kambin's Triangle were delineated, ensuring no overlap between the area and nerve above. RESULTS: Fifteen patients (67.5 ± 9.7 years, 46.7% female) were retrospectively reviewed. We measured 150 Kambin's Triangles. The mean areas from L1-S1 were 50.0 ± 12.3 mm2, 73.8 ± 12.5 mm2, 83.8 ± 12.2 mm2, 88.5 ± 19.0 mm2, and 116 ± 29.3 mm2, respectively. When pathology was present, the areas significantly decreased at L4-L5 (P = 0.046) and L5-S1 (P = 0.049). Higher spondylolisthesis and smaller posterior disk heights were linked with decreased areas via linear regression analysis (P < 0.05). When nerve segmentation was used, the areas were significantly smaller from L1-L5 (P < 0.05). Among 11 patients who underwent surgery, none suffered from postoperative neuropathies. CONCLUSIONS: These results illustrate the feasibility of preoperatively segmenting lumbosacral nerves and measuring Kambin's Triangle to help guide surgical planning and determine the ideal laterality of approach for percLIF.

13.
JMIR Form Res ; 7: e42172, 2023 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-36705962

RESUMO

BACKGROUND: Loneliness is a significant well-being issue that affects older adults. Existing, commonly used social connection platforms do not contain facilities to break the cognitive cycle of loneliness, and loneliness interventions implemented without due processes could have detrimental effects on well-being. There is also a lack of digital technology designed with older adults. OBJECTIVE: We aimed to iteratively design a user-centered smartphone app that can address loneliness in older adults. The aim of this study was to investigate the loneliness-related psychological processes that our conceptual smartphone app promotes. We also identified the emergent needs and concerns that older adults raised regarding the potential benefits and detriments of the app. METHODS: We used technology probes to elicit older adults' reflections on the concept of using the app in 2 studies as follows: concept focus groups (n=33) and concept interviews (n=10). We then conducted a prototype trial with 1 week of use and follow-up interviews (n=12). RESULTS: Thematic analysis explored the experiences and emergent challenges of our app through the design process. This led to the development of 4 themes as follows occurring in all 3 qualitative data sets: reflection on a digital social map is reassuring; app features encourage socializing; the risk of compounding loneliness; and individuals feel more control with mutual, socially beneficial activities. CONCLUSIONS: Smartphone apps have the potential to increase older adults' awareness of the richness of their social connections, which may support loneliness reduction. Our qualitative approach to app design enabled the inclusion of older adults' experiences in technology design. Thus, we conclude that the older adults in our study most desired functionalities that can support mutual activities and maintain or find new connections rather than enable them to share an emotional state. They were wary of the app replacing their preferred in-person social interaction. Participants also raised concerns about making the user aware of the lack of support in their social network and wanted specific means of addressing their needs. Further user-centered design work could identify how the app can support mutual activities and socializing.

14.
World Neurosurg ; 172: e389-e395, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36649859

RESUMO

BACKGROUND: The accuracy of pedicle screws placed with instrument tracking and robotic navigation are individually comparable or superior to placement using standard fluoroscopy, however head-to-head comparisons between these adjuncts in a similar surgical population have yet to be performed. METHODS: Consecutive patients undergoing percutaneous thoracic and lumbosacral spinal instrumentation were retrospectively enrolled. Instrumentation was performed using either fluoroscopy-based instrument tracking system (TrackX, TrackX Technologies) or robotic-navigation (ExcelsiusGPS, Globus Medical). Postinstrumentation computed tomography scans were graded for breach according to the Gertzbein-Robbins scale, with "acceptable" screws deemed as Grade A or B and "unacceptable" screws deemed as Grades C through E. Accuracy data was compared between both instrumentation modalities. RESULTS: Fifty-three patients, comprising a total of 250 screws (167 robot, 83 instrument tracking) were included. The overall accuracy between both modalities was similar, with 96.4% and 97.6% of screws with acceptable accuracy between instrument tracking and robotic navigation, respectively (I-squared 0.30, df = 1, P = 0.58). Between instrument tracking and robotic navigation, 92.8% and 95.8% of screws received Grade A, 3.6% and 1.8% a Grade B, 1.2% and 1.2% a Grade C, 1.2% and 0.6% a Grade D, and 1.2% and 0.6% a Grade E, respectively. The robot was abandoned intraoperatively in 2 cases due to unrecoverable registration inaccuracy or software failure, leading to abandonment of 8 potential screws (4.8%). CONCLUSIONS: In a similar patient population, there is a similarly high degree of instrumentation accuracy between fluoroscopy-based instrument tracking and robotic navigation. There is a rare chance for screw breach with either surgical adjunct.


Assuntos
Parafusos Pediculares , Procedimentos Cirúrgicos Robóticos , Robótica , Fusão Vertebral , Cirurgia Assistida por Computador , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Fluoroscopia/métodos , Fusão Vertebral/métodos
15.
JMIR Hum Factors ; 9(2): e34606, 2022 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-35475781

RESUMO

BACKGROUND: The global population is aging, leading to shifts in health care needs. In addition to developing technology to support physical health, there is an increasing recognition of the need to consider how technology can support emotional health. This raises the question of how to design devices that older adults can interact with to log their emotions. OBJECTIVE: We designed and developed 2 novel tangible devices, inspired by existing paper-based scales of emotions. The findings from a field trial of these devices with older adults are reported. METHODS: Using interviews, field deployment, and fixed logging tasks, we assessed the developed devices. RESULTS: Our results demonstrate that the tangible devices provided data comparable with standardized psychological scales of emotion. The participants developed their own patterns of use around the devices, and their experience of using the devices uncovered a variety of design considerations. We discuss the difficulty of customizing devices for specific user needs while logging data comparable to psychological scales of emotion. We also highlight the value of reflecting on sparse emotional data. CONCLUSIONS: Our work demonstrates the potential for tangible emotional logging devices. It also supports further research on whether such devices can support the emotional health of older adults by encouraging reflection of their emotional state.

16.
Comput Hum Behav Rep ; 6: 100179, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35233473

RESUMO

The COVID-19 pandemic is worsening loneliness for many older people through the challenges it poses in engaging with their social worlds. Digital technology has been offered as a potential aid, however, many popular digital tools have not been designed to address the needs of older adults during times of limited contact. We propose that the Social Identity Model of Identity Change (SIMIC) could be a foundation for digital loneliness interventions. While SIMIC is a well-established approach for maintaining wellbeing during life transitions, it has not been rigorously applied to digital interventions. There are known challenges to integrating psychological theory in the design of digital technology to enable efficacy, technology acceptance, and continued use. The interdisciplinary field of Human Computer Interaction has a history of drawing on models originating from psychology to improve the design of digital technology and to design technologies in an appropriate manner. Drawing on key lessons from this literature, we consolidate research and design guidelines for multidisciplinary research applying psychological theory such as SIMIC to digital social interventions for loneliness.

17.
World Neurosurg ; 162: 118-125.e1, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35339713

RESUMO

In recent years, physicians and institutions have come to recognize the increasing opioid epidemic in the United States, thus prompting a dramatic shift in opioid prescribing patterns. The lack of well-studied alternative treatment regimens has led to a substantial burden of opioid addiction in the United States. These forces have led to a huge economic burden on the country. The spine surgery population is particularly high risk for uncontrolled perioperative pain, because most patients experience chronic pain preoperatively and many patients continue to experience pain postoperatively. Overall, there is a large incentive to better understand comprehensive multimodal pain management regimens, particularly in the spine surgery patient population. The goal of this review is to explore trends in pain symptoms in spine surgery patients, overview the best practices in pain medications and management, and provide a concise multimodal and behavioral treatment algorithm for pain management, which has since been adopted by a high-volume tertiary academic medical center.


Assuntos
Analgésicos Opioides , Transtornos Relacionados ao Uso de Opioides , Humanos , Transtornos Relacionados ao Uso de Opioides/prevenção & controle , Manejo da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/tratamento farmacológico , Padrões de Prática Médica , Estados Unidos
18.
Clin Spine Surg ; 35(1): E248-E258, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34149006

RESUMO

STUDY DESIGN: Retrospective cohort study using the National Surgical Quality Improvement Program. OBJECTIVE: The objective of this study was to identify preoperative factors that impact the decision to perform prophylactic muscle flap closure and assess risk factors for wound healing complications in patients undergoing spinal procedures with and without muscle flap closure. SUMMARY OF BACKGROUND DATA: Prior studies suggest that muscle flap closure following complex spine surgery results in a lower risk of wound healing complications. However, these studies have been limited to single institutions and/or surgeons. METHODS: The National Surgical Quality Improvement Program database was queried for all patients undergoing spine surgery between 2005 and 2017 with and without concomitant muscle flaps. Preoperative and perioperative variables were extracted. Univariate and multivariate analyses were performed to assess risk factors influencing surgical site infection (SSI) and wound disruption, as well as to delineate which preoperative factors increased the likelihood of patients receiving flap closures a priori. RESULTS: Concomitant muscle flaps were performed on 758 patients; 301,670 patients did not receive a flap. Overall 29 (3.83%) patients in the flap group experienced SSI compared to 5154 (1.71%) in the nonflap group (P<0.0001). Preoperative steroid use [odds ratio (OR) 0.5; P<0.0001], wound infection (OR 0.24; P<0.0001), elevated white blood cell count (OR 1.034; P<0.0001), low hematocrit (OR 0.94; P<0.0001), preoperative transfusion (OR 0.22; P=0.0068) were significantly associated with utilization of muscle flaps. Perioperative factors including a contaminated wound (OR 4.72; P<0.0001), the American Society of Anesthesiologists classification of severe disease (OR 1.92; P=0.024), and longer operative time (OR 1.001; P=0.0024) were significantly associated with postoperative wound disruption. In addition, after propensity score matching for these factors that increase risk of wound complications, there was no difference in the rates of SSI between the flap and nonflap group. CONCLUSION: Our results suggest that patients with a higher burden of illness preoperatively are more likely to receive prophylactic paraspinal flaps which can reduce the rates of wound-related complications.


Assuntos
Retalhos Cirúrgicos , Infecção da Ferida Cirúrgica , Humanos , Músculos , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos , Fatores de Risco , Coluna Vertebral/cirurgia , Infecção da Ferida Cirúrgica/etiologia
19.
J Neurosurg Spine ; : 1-10, 2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-35180705

RESUMO

OBJECTIVE: Minimally invasive surgery (MIS) for adult spinal deformity (ASD) can offer deformity correction with less tissue manipulation and damage. However, the impact of obesity on clinical outcomes and radiographic correction following MIS for ASD is poorly understood. The goal of this study was to determine the role, if any, that obesity has on radiographic correction and health-related quality-of-life measures in MIS for ASD. METHODS: Data were collected from a multicenter database of MIS for ASD. This was a retrospective review of a prospectively collected database. Patient inclusion criteria were age ≥ 18 years and coronal Cobb angle ≥ 20°, pelvic incidence-lumbar lordosis mismatch ≥ 10°, or sagittal vertical axis (SVA) > 5 cm. A group of patients with body mass index (BMI) < 30 kg/m2 was the control cohort; BMI ≥ 30 kg/m2 was used to define obesity. Obesity cohorts were categorized into BMI 30-34.99 and BMI ≥ 35. All patients had at least 1 year of follow-up. Preoperative and postoperative health-related quality-of-life measures and radiographic parameters, as well as complications, were compared via statistical analysis. RESULTS: A total of 106 patients were available for analysis (69 control, 17 in the BMI 30-34.99 group, and 20 in the BMI ≥ 35 group). The average BMI was 25.24 kg/m2 for the control group versus 32.46 kg/m2 (p < 0.001) and 39.5 kg/m2 (p < 0.001) for the obese groups. Preoperatively, the BMI 30-34.99 group had significantly more prior spine surgery (70.6% vs 42%, p = 0.04) and worse preoperative numeric rating scale leg scores (7.71 vs 5.08, p = 0.001). Postoperatively, the BMI 30-34.99 cohort had worse Oswestry Disability Index scores (33.86 vs 23.55, p = 0.028), greater improvement in numeric rating scale leg scores (-4.88 vs -2.71, p = 0.012), and worse SVA (51.34 vs 26.98, p = 0.042) at 1 year postoperatively. Preoperatively, the BMI ≥ 35 cohort had significantly worse frailty (4.5 vs 3.27, p = 0.001), Oswestry Disability Index scores (52.9 vs 44.83, p = 0.017), and T1 pelvic angle (26.82 vs 20.71, p = 0.038). Postoperatively, after controlling for differences in frailty, the BMI ≥ 35 cohort had significantly less improvement in their Scoliosis Research Society-22 outcomes questionnaire scores (0.603 vs 1.05, p = 0.025), higher SVA (64.71 vs 25.33, p = 0.015) and T1 pelvic angle (22.76 vs 15.48, p = 0.029), and less change in maximum Cobb angle (-3.93 vs -10.71, p = 0.034) at 1 year. The BMI 30-34.99 cohort had significantly more infections (11.8% vs 0%, p = 0.004). The BMI ≥ 35 cohort had significantly more implant complications (30% vs 11.8%, p = 0.014) and revision surgery within 90 days (5% vs 1.4%, p = 0.034). CONCLUSIONS: Obese patients who undergo MIS for ASD have less correction of their deformity, worse quality-of-life outcomes, more implant complications and infections, and an increased rate of revision surgery compared with their nonobese counterparts, although both groups benefit from surgery. Appropriate counseling should be provided to obese patients.

20.
Oper Neurosurg (Hagerstown) ; 21(Suppl 1): S12-S22, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-34128071

RESUMO

Spinal fusion has undergone significant evolution and improvement over the past 50 yr. Historically, spine fusion was noninstrumented and arthrodesis was based entirely on autograft. Improved understanding of spinal anatomy and materials science ushered in a new era of spinal fusion equipped with screw-based technologies and various interbody devices. Osteobiologics is another important realm of spine fusion, and the evolution of various osteobiologics has perhaps undergone the most change within the past 20 yr. A new element to spinal instrumentation has recently gained traction-namely, surface technology. New data suggest that surface treatments play an increasingly well-recognized role in inducing osteogenesis and successful fusion. Until now, however, there has yet to be a unified resource summarizing the existing data and a lack of consensus exists on superior technology. Here, authors provide an in-depth review on surface technology and its impact on spinal arthrodesis.


Assuntos
Doenças da Coluna Vertebral , Fusão Vertebral , Parafusos Ósseos , Humanos , Doenças da Coluna Vertebral/diagnóstico por imagem , Doenças da Coluna Vertebral/cirurgia , Coluna Vertebral , Tecnologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA