Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
ASAIO J ; 69(3): e121-e124, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-35696694

RESUMO

Reverse cardiac remodeling may occur in some left ventricular assist device (LVAD) recipients. Although considered the standard therapy, surgical device explantation with repeat sternotomy might be undesirable or very high risk. On the other hand, there are few data reporting minimally invasive percutaneous LVAD deactivation. We describe a case of a man with LVAD malfunction due to driveline fracture and left ventricular (LV) function recovery who had a Heart Mate II deactivated with a percutaneous technique using a left atrial appendage occluder (LAAO) positioned inside the outflow cannula. To the best of our knowledge, this the first report of LVAD deactivation with the fully recapturable LAAO device. We propose that the use of a LAA occluder to obstruct HM II outflow cannula is feasible and safe.


Assuntos
Apêndice Atrial , Coração Auxiliar , Masculino , Humanos , Coração Auxiliar/efeitos adversos , Cânula , Função Ventricular Esquerda/fisiologia , Esternotomia
3.
Cardiovasc Diagn Ther ; 5(6): 414-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26675281

RESUMO

BACKGROUND: The present study aimed to evaluate the clinical performance, in the daily practice of a busy catheterization laboratory, of a novel drug-eluting stent (DES) built with an ultra-thin-strut metallic platform, eluting sirolimus at low doses, abluminal coated with biodegradable polymers, and mounted in a low-compliant delivery system. METHODS: Prospective, single-arm study, comprising all consecutive patients undergoing percutaneous coronary intervention (PCI) with the Inspiron™ sirolimus-eluting stent (SES) (Scitech, Aparecida de Goiania, Brazil). The primary endpoint was the occurrence of major adverse cardiac events (MACE) [cardiac death, non-PCI related myocardial infarction (MI), or target vessel revascularization (TVR)]. RESULTS: A total of 470 patients were included, from which 51.3% were diabetics, 33.8% had triple-vessel disease, 15.3% had heart failure, 38.9% had at least one bifurcation treated, 19.8% were treated for a bare metal stent restenosis, and 61.9% had at least one type C lesion; one or more of these features were found in 96.0%. At 300 days, the rate target lesion revascularization was 5.4% and the rate of MACE was 8.1%. The incidence of definite or probable stent thrombosis was 0.4%, with no cases between 30 and 300 days. CONCLUSIONS: The novel stent is associated with excellent short and mid-term clinical outcomes in patients treated with PCI in the daily practice.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA