Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
1.
Cardiovasc Diabetol ; 23(1): 198, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38867198

RESUMO

BACKGROUND: The TIM-HF2 study demonstrated that remote patient management (RPM) in a well-defined heart failure (HF) population reduced the percentage of days lost due to unplanned cardiovascular hospital admissions or all-cause death during 1-year follow-up (hazard ratio 0.80) and all-cause mortality alone (HR 0.70). Higher rates of hospital admissions and mortality have been reported in HF patients with diabetes compared with HF patients without diabetes. Therefore, in a post-hoc analysis of the TIM-HF2 study, we investigated the efficacy of RPM in HF patients with diabetes. METHODS: TIM-HF2 study was a randomized, controlled, unmasked (concealed randomization), multicentre trial, performed in Germany between August 2013 and May 2018. HF-Patients in NYHA class II/III who had a HF-related hospital admission within the previous 12 months, irrespective of left ventricular ejection fraction, and were randomized to usual care with or without added RPM and followed for 1 year. The primary endpoint was days lost due to unplanned cardiovascular hospitalization or due to death of any cause. This post-hoc analysis included 707 HF patients with diabetes. RESULTS: In HF patients with diabetes, RPM reduced the percentage of days lost due to cardiovascular hospitalization or death compared with usual care (HR 0.66, 95% CI 0.48-0.90), and the rate of all-cause mortality alone (HR 0.52, 95% CI 0.32-0.85). RPM was also associated with an improvement in quality of life (mean difference in change in global score of Minnesota Living with Heart Failure Questionnaire score (MLHFQ): - 3.4, 95% CI - 6.2 to - 0.6). CONCLUSION: These results support the use of RPM in HF patients with diabetes. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov NCT01878630.


Assuntos
Diabetes Mellitus , Insuficiência Cardíaca , Telemedicina , Humanos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Fatores de Tempo , Resultado do Tratamento , Alemanha/epidemiologia , Diabetes Mellitus/mortalidade , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/terapia , Fatores de Risco , Hospitalização , Causas de Morte , Idoso de 80 Anos ou mais , Admissão do Paciente
2.
Kidney Blood Press Res ; 44(4): 765-776, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31387104

RESUMO

BACKGROUND: Kynurenine, a metabolite of the L-tryptophan pathway, plays a pivotal role in neuro-inflammation, cancer immunology, and cardiovascular inflammation, and has been shown to predict cardiovascular events. OBJECTIVES: It was our objective to increase the body of data regarding the value of kynurenine as a biomarker in chronic heart failure (CHF). METHODS: We investigated the predictive value of plasma kynurenine in a CHF cohort (CHF, n = 114); in a second cohort of defibrillator carriers with CHF (AICD, n = 156), we determined clinical and biochemical determinants of the marker which was measured by enzyme immunoassay. RESULTS: In the CHF cohort, both kynurenine and NT-proBNP increased with NYHA class. Univariate binary logistic regression showed kynurenine to predict death within a 6-month follow-up (OR 1.43, 95% CI 1.03-2.00, p = 0.033) whereas NT-proBNP did not contribute significantly. Kynurenine, like NT-proBNP, was able to discriminate at a 30% threshold of left ventricular ejection fraction (LVEF; AUC-ROC, both 0.74). Kynurenine correlated inversely with LVEF (ϱ = -0.394), glomerular filtration fraction (GFR; ϱ = -0.615), and peak VO2 (ϱ = -0.626). Moreover, there was a strong correlation of kynurenine with NT-proBNP (ϱ = 0.615). In the AICD cohort, multiple linear regression analysis demonstrated highly significant associations of kynurenine with GFR, hsCRP, and tryptophan, as well as a significant impact of age. CONCLUSIONS: This work speaks in favor of kynurenine being a new and valuable biomarker of CHF, with particular attention placed on its ability to predict mortality and reflect exercise capacity.


Assuntos
Insuficiência Cardíaca/diagnóstico , Cinurenina/sangue , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Doença Crônica , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/patologia , Humanos , Imunoensaio , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Valor Preditivo dos Testes , Volume Sistólico , Função Ventricular Esquerda
3.
Clin Lab ; 63(11): 1911-1918, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29226642

RESUMO

BACKGROUND: Homoarginine (hArg) is known to have an impact on nitric oxide (NO) metabolism. It seems to increase NO generation and/or availability, thereby enhancing endothelial function. In addition, hArg is connected to energy metabolism since the key enzyme, L-arginine-glycine amidinotransferase (AGAT) for hArg synthesis in the kidneys, is also involved in the synthesis of energy metabolites like guanidinoacetate. Former studies indicate that low levels of hArg are linked to cardiovascular disease and increased all-cause mortality. METHODS: This study investigated the dependence of plasma hArg on various biochemical and clinical factors in 229 patients carrying an automatic, implantable cardioverter/defibrillator (AICD) using multiple linear regression analysis (Generalized Linear Model, GLM). RESULTS: GLM revealed a highly significant, positive association between hArg and zonulin (p < 0.001). hArg was also positively correlated with tryptophan (p = 0.004), BMI (p = 0.02), and body weight (p = 0.02). Patients with hsCRP above 10 mg/L had significantly lower hArg concentrations than patients with hsCRP ≤ 10 mg/L. CONCLUSIONS: The highly significant positive association of hArg with zonulin is a novel finding which may indicate a different meaning of circulating versus local (gut) zonulin. Therefore, further experimental and clinical investigation is needed to explore this association, focusing on possible pathophysiological pathways and the role of circulating zonulin levels in cardiovascular disease. The positive correlation of hArg and Trp also deserves further research because both amino acids might have a protective effect on cardiovascular disease by inhibition of the enzyme alkaline phosphatase. Eventually, our study associates low hArg concentrations with chronic low-grade inflammation and parameters of malnutrition in cardiovascular high-risk patients.


Assuntos
Toxina da Cólera/sangue , Homoarginina/sangue , Triptofano/sangue , Idoso , Estudos de Coortes , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Feminino , Haptoglobinas , Humanos , Masculino , Pessoa de Meia-Idade , Precursores de Proteínas
4.
Clin Lab ; 62(12): 2443-2447, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28164545

RESUMO

BACKGROUND: The tight junction regulator zonulin has attracted clinical attention as a biomarker of increased gastrointestinal permeability. Recent work also suggests zonulin to represent a general regulator of tissue barriers and a player in metabolic inflammation. Here, we investigated the associations of zonulin with chronic heart failure (CHF), kidney function, and metabolic inflammation. METHODS: Using multiple linear regression (Generalized Linear Model), this study determined the association of plasma zonulin with different laboratory and clinical parameters in 225 patients carrying automatic implantable cardioverters/defibrillators (AICD) for primary or secondary prevention. In another 115 patients with diastolic or systolic CHF, we investigated a possible relationship between zonulin and CHF severity. RESULTS: In the AICD cohort, zonulin associated inversely with serum creatinine (p = 0.013), carboxymethyl-lysine calprotectin (p < 0.001), and kynurenine (p = 0.009) and positively with homoarginine (p < 0.001). In the subgroup with type-2 diabetes (T2D) (n = 51), zonulin increased significantly with high-sensitivity CRP (p = 0.014). In the CHF cohort, we found a highly significant rise of NT-proBNP, but not of zonulin with NYHA functional classes I-IV or other parameters of CHF severity. CONCLUSIONS: The inverse associations of zonulin with creatinine and markers of cardio-vascular risk (high CMLcalprotectin and kynurenine, low homoarginine) are novel findings that need further experimental and clinical clarification. Our study indicates zonulin involvement in metabolic inflammation in T2D, but no association with disease status in CHF.


Assuntos
Toxina da Cólera/sangue , Insuficiência Cardíaca/sangue , Inflamação/sangue , Nefropatias/sangue , Rim/fisiopatologia , Doenças Metabólicas/sangue , Idoso , Biomarcadores/sangue , Feminino , Haptoglobinas , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Inflamação/diagnóstico , Nefropatias/diagnóstico , Nefropatias/fisiopatologia , Modelos Lineares , Masculino , Doenças Metabólicas/diagnóstico , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Precursores de Proteínas , Índice de Gravidade de Doença
5.
Pacing Clin Electrophysiol ; 37(10): 1291-6, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24888641

RESUMO

BACKGROUND: Postoperative lead perforation is a life-threatening complication of cardiac pacing. Identification of precipitating factors for this serious complication may help to anticipate a specific risk profile and to minimize the incidence. METHODS: We conducted a retrospective tertiary referral center analysis to clarify clinical, anatomical, and technical characteristics related to pacemaker (PM) and cardioverter/defibrillator lead perforation. We examined the baseline characteristics and the symptoms. In a subgroup, we investigated the myocardial thickness on contrast-enhanced cardiac computed tomography. RESULTS: We enrolled 26 patients. Female gender appears to put patients at slightly increased risk for lead perforation. In a majority active fixation leads were used. Symptoms occurred in 72%. Pericardial effusion and tamponade were present in 38% and 19%, respectively. Sensing was compromised in 65%. A high pacing threshold or exit block occurred in 92%. Myocardial thickness did not differ between patients with or without perforation. In 96%, the perforation was treated by transvenous withdrawal. CONCLUSION: Chest pain, phrenic stimulation, bad sensing, or exit block early after PM implantation must prompt radiological and echocardiographic evaluation. A missing pericardial effusion particularly late after implantation does not rule out a perforation. Especially active fixating leads have a higher risk of perforation. With cardiac surgery in standby transvenous withdrawal is a safe way to treat lead perforation.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Traumatismos Cardíacos/etiologia , Coração/anatomia & histologia , Marca-Passo Artificial/efeitos adversos , Complicações Pós-Operatórias/etiologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Derrame Pericárdico , Estudos Retrospectivos , Fatores de Risco
6.
Pacing Clin Electrophysiol ; 36(1): 63-8, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23121169

RESUMO

AIMS: The role of right bundle branch block (RBBB) for the induction of left ventricular (LV) asynchrony is discussed controversially. The objective of this study was to assess presence and degree of LV asynchrony in patients with RBBB, left bundle branch block (LBBB), or left anterior hemiblock (LAH) and normal LV function. METHODS: We included 15 patients with RBBB, 13 patients with RBBB and concomitant LAH, 10 patients with pure LBBB, and 100 healthy controls into this study. All patients had normal LV function. Interventricular asynchrony was assessed as the difference of the right and LV ejection delay. Intraventricular delay was obtained by tissue synchronicity imaging-guided tissue Doppler imaging measurement. RESULTS: Interventricular and left intraventricular asynchrony were linked to the presence of an LBBB. No left intraventricular asynchrony was noted during pure RBBB; interventricular delays were negative (aortic flow preceding pulmonary flow) in the presence of RBBB. CONCLUSION: In patients with normal LV function, intraventricular asynchrony depends on the presence of an LBBB and interventricular asynchrony is inversed in the presence of RBBB.


Assuntos
Bloqueio de Ramo/complicações , Bloqueio de Ramo/diagnóstico por imagem , Técnicas de Imagem por Elasticidade/métodos , Volume Sistólico , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico por imagem , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Pacing Clin Electrophysiol ; 36(7): 898-903, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23607531

RESUMO

INTRODUCTION: Atrioventricular (AV) block is a frequent complication of transcatheter aortic valve implantation (TAVI). TAVI is routinely performed under anticoagulation using heparin, which potentially may lead to an increased bleeding rate in patients who undergo permanent pacemaker (PPM) implantation immediately after TAVI. As the number of TAVI procedures continues to rise, data on the optimal management of TAVI-related AV block are needed. Therefore, the aim of our study was to analyze PPM implantation-related complications after TAVI. METHODS: We retrospectively collected data on PPM implantations after TAVI in our center from January 2010 to December 2012. In total, we included 30 patients who received a PPM for TAVI-related AV block. Twelve patients (group A) underwent PPM implantation on the day of TAVI. In 18 patients (group B), PPM implantation was performed at least 1 day after TAVI (3.8 ± 4.5 days). Since all patients undergoing TAVI receive dual antiplatelet therapy (DA-therapy), we compared all implantations after TAVI with a historic patient cohort that underwent PPM implantation under DA-therapy. RESULTS: Procedure times, fluid loss via drainage systems, and drainage times were neither significantly different between groups A and B nor between all PPM implantations after TAVI compared to the historic control group. CONCLUSION: PPM implantation immediately after TAVI is safe and can be performed without increased rate of complications.


Assuntos
Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bloqueio Atrioventricular/epidemiologia , Bloqueio Atrioventricular/prevenção & controle , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Marca-Passo Artificial/estatística & dados numéricos , Idoso , Comorbidade , Feminino , Alemanha/epidemiologia , Humanos , Incidência , Masculino , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
8.
Europace ; 14(2): 238-42, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21846642

RESUMO

AIMS: The prevalence of pacing-induced cardiomyopathy (PiCMP) has been reported to be 9% 1 year after implantation. As long-term data are sparse, the aim of our study was to evaluate the prevalence of PiCMP in a cohort of patients with at least 15 years of right ventricular (RV) pacing. METHODS AND RESULTS: Inclusion criteria were RV stimulation for at least 15 years due to atrioventricular block III° and absence of structural heart disease at the time of initial implantation. All patients were examined by echocardiography and spiroergometry. Pacing-induced cardiomyopathy was pre-defined as left ventricular (LV) ejection fraction (LVEF) ≤45%, dyskinesia during RV pacing and absence of other known causes of cardiomyopathy. Twenty-six patients from our outpatient department met the inclusion criteria. Pacing-induced cardiomyopathy was diagnosed in four patients (15.4%). Echocardiography showed significant LV remodelling in PiCMP patients [LVEF 41.0 ± 4.5%, LV end-diastolic diameter (LVEDD) 54.0 ± 2.7 mm] compared with patients with preserved LVEF (LVEF 61.2 ± 5.8%, P = 0.002, LVEDD 45.6 ± 4.0 mm, P= 0.004). There were no significant differences regarding age, gender, duration of RV pacing, heart rate, interventricular mechanical delay, QRS duration or prevalence of sinus rhythm, and arterial hypertension between both groups. The longest intraventricular delay was significantly shorter in patients with preserved LVEF (65.5 ± 43.0 ms) compared with PiCMP patients (112.5 ± 15.0 ms, P= 0.043). Exercise capacity and quality of life did not differ significantly between both groups. CONCLUSION: Considering the very long duration of RV stimulation in our study population (24.6 ± 6.6 years), the prevalence of PiCMP was remarkably low. Pacing-induced cardiomyopathy was associated with more pronounced intraventricular dyssynchrony.


Assuntos
Terapia de Ressincronização Cardíaca/mortalidade , Cardiomiopatias/epidemiologia , Disfunção Ventricular Direita/mortalidade , Disfunção Ventricular Direita/prevenção & controle , Comorbidade , Feminino , Alemanha/epidemiologia , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Prevalência , Medição de Risco , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida
9.
Europace ; 14(5): 696-702, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22117035

RESUMO

AIMS: Interventricular (VV) delay optimization for cardiac resynchronization therapy (CRT) is recommended by current guidelines and several algorithms have been proposed. So far, however, no gold standard has been established in the clinical routine. We hypothesized that dyssynchrony parameter assessment might guide VV delay optimization and investigated whether dyssynchrony parameter changes induced by sequential biventricular pacing follow a predictable pattern. METHODS AND RESULTS: We determined intra- and interventricular dyssynchrony in 80 CRT patients by echocardiographic quantification of the interventricular mechanical delay and the septal-lateral time to peak systolic velocity delay. Dyssynchrony parameters were assessed during simultaneous biventricular pacing as well as during sequential biventricular pacing with a right ventricular (RV) or left ventricular (LV) preactivation of 40 ms. Simultaneous biventricular pacing significantly improved inter- and intraventricular dyssynchrony parameters compared with preoperative baseline measurements. In general, dyssynchrony parameter changes induced by sequential biventricular pacing showed high interindividual variance and did not follow a predictable pattern. Intra- or interventricular dyssynchrony persisted during simultaneous biventricular pacing in 39 and 19% of our patients, respectively. Neither RV nor LV preactivation significantly decreased the number of patients with persistent intraventricular dyssynchrony. In contrast, LV preactivation significantly reduced the prevalence of interventricular dyssynchrony by 80%. CONCLUSIONS: Left ventricular preactivation effectively ameliorates interventricular dyssynchrony, which persists in almost one in five CRT patients. Assessment of interventricular dyssynchrony and consecutive programming of LV preactivation in patients with persistent interventricular dyssynchrony may represent a pragmatic and time-effective approach to improve CRT in patients with inferior response.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Terapia de Ressincronização Cardíaca/normas , Insuficiência Cardíaca/terapia , Disfunção Ventricular Esquerda/prevenção & controle , Idoso , Feminino , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Guias de Prática Clínica como Assunto , Prevalência , Padrões de Referência , Volume Sistólico/fisiologia , Sístole/fisiologia , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/epidemiologia , Disfunção Ventricular Esquerda/fisiopatologia
10.
Pacing Clin Electrophysiol ; 35(10): 1217-21, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22845624

RESUMO

BACKGROUND: Cardiac device infections are serious complications that require aggressive treatment strategies, including interventional or surgical lead extraction. METHODS: Here we describe the long-time follow-up of vacuum-assisted closure (V.A.C.) treatment in five patients with local cardiac device infection (LDI). In these patients the device was removed, the electrodes were shortened, and a V.A.C. treatment was applied. The primary endpoint was defined as time to re-LDI. RESULTS: Three patients had LDI of a pacemaker pocket, whereas two presented with an infection of their ICD pocket. The V.A.C. treatment was applied for 34.4 ± 17.9 days. The mean hospitalization time was 38.6 ± 19.2 days. The follow-up period was assessed for 34.6 ± 19.2 months. Only one patient developed re-LDI, 69 days after removal of the device. The other four patients did not show any signs of reinfection during the follow-up period. None of the five patients sustained serious adverse events. CONCLUSIONS: V.A.C. treatment may be an option for selected patients with LDI who refuse a laser-guided lead extraction or surgical removal of the electrodes as the primary therapy.


Assuntos
Desfibriladores Implantáveis/microbiologia , Tratamento de Ferimentos com Pressão Negativa , Marca-Passo Artificial/microbiologia , Infecção da Ferida Cirúrgica/terapia , Idoso , Idoso de 80 Anos ou mais , Desbridamento , Humanos , Tempo de Internação , Masculino , Staphylococcus aureus Resistente à Meticilina/isolamento & purificação , Recidiva , Infecções Estafilocócicas/terapia , Resultado do Tratamento , Cicatrização
11.
Int J Cardiol ; 349: 79-81, 2022 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-34826499

RESUMO

Cardiac implantable electronic device (CIED)-related infections are a major complication of CIED therapy and associated with high morbidity and mortality. The aim of the present study was to evaluate the incidence of lead erosion as one cause of the CIED-related infections and to provide detailed information about the therapy of two cases of lead erosion. We retrospectively screened the database of a large clinic specialized on patients with CIED (HIZ BERLIN Herzschrittmacher- und ICD-Zentrum, Berlin, Germany) for cases of lead erosion between 2015 and 2020. A total of 5971 outpatients were treated at the HIZ BERLIN - including 4782 patients with a one- or two-chamber pacemaker, 837 patients with an implantable cardioverter defibrillator (ICD) and 352 patients with a biventricular device for cardiac resynchronization therapy (CRT). The incidence of lead erosion was 0.033%. As one of the two patients, who suffered from lead erosions, had no signs of systemic infection, the patient received local therapy with an antimicrobial mesh and intravenous antibiotics. After twelve months, he showed a good clinical outcome without ongoing or recurring infection. In conclusion, the incidence of lead erosion is low. In case of lead erosions without signs of systemic infection, an antimicrobial mesh might be implanted as an off-label use in patients that decline complete device removal.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Antibacterianos/uso terapêutico , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Humanos , Incidência , Masculino , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/epidemiologia , Infecções Relacionadas à Prótese/terapia , Estudos Retrospectivos , Fatores de Risco , Telas Cirúrgicas
12.
Pacing Clin Electrophysiol ; 33(4): 394-9, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20025706

RESUMO

BACKGROUND: Device implantations in patients on dual antiplatelet-therapy (DA-therapy) continue to rise. The aim of our study was to compile and analyze data on complications of antiarrhythmia device implantation under DA-therapy. METHODS: We prospectively collected data on all device implantations in our department from January 2008 until February 2009. The control group was comprised of patients on acetylsalicylic acid alone or no antiplatelet medication at all (318 subjects). The DA-therapy group consisted of 109 patients of whom 71 were analyzed retrospectively (implantations from 2002 to 2007). RESULTS: Procedure times were significantly longer in DA-therapy patients receiving a pacemaker for the first time. In contrast, procedure times did not differ significantly between the two study groups for implantable cardioverter defibrillator (ICD) implantations and for pacemaker replacements. Fluid losses via drainage systems and drainage times were significantly increased in the DA-therapy group as compared with the control group after pacemaker but not after ICD implantations. Importantly, there were no significant differences in complication rates, particularly the hematoma rate, between the DA-therapy and the control group. CONCLUSIONS: When drainage systems are used, antiarrhythmia device implantation is safe and can be performed without significantly increased risk of clinically relevant hematoma in patients on continued DA-therapy. (PACE 2010; 394-399).


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Inibidores da Agregação Plaquetária/uso terapêutico , Implantação de Prótese/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Feminino , Hematoma/induzido quimicamente , Humanos , Masculino , Pessoa de Meia-Idade , Inibidores da Agregação Plaquetária/efeitos adversos , Complicações Pós-Operatórias/induzido quimicamente , Estudos Prospectivos , Estudos Retrospectivos
13.
Cardiovasc Ultrasound ; 8: 35, 2010 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-20809960

RESUMO

BACKGROUND: Cardiac resynchronization therapy (CRT) is generally associated with a low to moderate increase of the left ventricular ejection fraction (LVEF). In some patients, however, LVEF improves remarkably and reaches near-normal values. The aim of the present study was to further characterize these so called 'super-responders' with a special focus on the extent of intra- and interventricular asynchrony before and after device implantation compared to average responders. METHODS: 37 consecutive patients who underwent CRT device implantation according to current guidelines were included in the study. Patients were examined by echocardiography before, one day after and six months after device implantation. Pre-defined criterion for superior response to CRT was an LVEF increase > 15% after six months. RESULTS: At follow-up, eight patients (21.6%) were identified as super-responders. There were no significant differences regarding age, gender, prevalence of ischemic heart disease and LVEF between average and super-responders at baseline. After six months, LVEF had significantly increased from 26.7% ± 5.7% to 33.1% ± 7.9% (p < 0.001) in average and from 24.0% ± 6.7% to 50.3% ± 7.4% (p < 0.001) in super-responders. Both groups showed a significant reduction of QRS duration as well as LV end-diastolic and -systolic volumes under CRT. At baseline, the interventricular mechanical delay (IVMD) was 53.7 ± 20.9 ms in average and 56.9 ± 22.4 ms in super-responders - representing a similar extent of interventricular asynchrony in both groups (p = 0.713). CRT significantly reduced the IVMD to 20.3 ± 15.7 (p < 0.001) in average and to 19.8 ± 15.9 ms (p = 0.013) in super-responders with no difference between both groups (p = 0.858). As a marker for intraventricular asynchrony, we assessed the longest intraventricular delay between six basal LV segments. At baseline, there was no difference between average (86.2 ± 30.5 ms) and super-responders (78.8 ± 23.6 ms, p = 0.528). CRT significantly reduced the longest intraventricular delay in both groups--with a significant difference between average (66.2 ± 36.2 ms) and super-responders (32.5 ± 18.3 ms, p = 0.022). Multivariate logistic regression analysis identified the longest intraventricular delay one day after device implantation as an independent predictor of superior response to CRT (p = 0.038). CONCLUSIONS: A significant reduction of the longest intraventricular delay correlates with superior response to CRT.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Remodelação Ventricular/fisiologia , Idoso , Ecocardiografia , Eletrocardiografia , Feminino , Seguimentos , Sistema de Condução Cardíaco/diagnóstico por imagem , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/inervação , Humanos , Masculino , Estudos Retrospectivos , Volume Sistólico/fisiologia , Resultado do Tratamento
14.
Herzschrittmacherther Elektrophysiol ; 31(2): 219-223, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32377903

RESUMO

BACKGROUND: Right ventricular (RV) pacing is the standard treatment for symptomatic bradycardia. RV pacing is known to cause dyssyncrony. New treatment options like His bundle pacing enhance the focus on left ventricular dysfunction in patients with pacemakers. OBJECTIVES: The aim of this cross-sectional study was to obtain a real-life picture of the patients in a representative cohort of outpatients with permanent pacemakers. The prevalence and causes of left ventricular dysfunction (LVD) were explored. METHODS: In total, 1869 patients of a pacemaker outpatient clinic were screened for left ventricular systolic dysfunction by transthoracic echocardiography. All patients were interviewed for symptoms and cardiologist care. Percentages of RV pacing and underlying cardiac disease were recorded. RESULTS: A left ventricular ejection fraction (LVEF) under 45% was found in 207 (11.1%) of all patients. Predictive factors for a reduced LVEF were a high pacing rate and long-term pacing. LVD due to RV pacing was diagnosed in 3.4% of all patients. Only 845 patients (45%) reported that they regularly visited a cardiologist. CONCLUSION: There is a high prevalence of unknown LVD in a typical pacemaker cohort. Therefore, regular echocardiographic examinations should be performed in outpatients of pacemaker clinics.


Assuntos
Marca-Passo Artificial , Disfunção Ventricular Esquerda , Idoso , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial , Estudos Transversais , Feminino , Humanos , Masculino , Pacientes Ambulatoriais , Prevalência , Volume Sistólico , Função Ventricular Esquerda
15.
Cardiovasc Ultrasound ; 7: 46, 2009 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-19781060

RESUMO

BACKGROUND: Established methods to determine asynchrony suffer from high intra- and interobserver variability and failed to improve patient selection for cardiac resynchronization therapy (CRT). Thus, there is a need for easy and robust approaches to reliably assess cardiac asynchrony. METHODS AND RESULTS: We performed echocardiography in 100 healthy subjects and 33 patients with left bundle branch block (LBBB). To detect intraventricular asynchrony, we combined two established methods, i.e., tissue synchronization imaging (TSI) and tissue Doppler imaging (TDI). The time intervals from the onset of aortic valve opening (AVO) to the peak systolic velocity (S') were measured separately in six basal segments in the apical four-, two-, and three-chamber view. Color-coded TSI served as an intrinsic plausibility control and helped to identify the correct S' measuring point in the TDI curves. Next, we identified the segment with the shortest AVO-S' interval. Since this segment most likely represents vital and intact myocardium it served as a reference for other segments. Segments were considered asynchronous when the delay between the segment in question and the reference segment was above the upper limit of normal delays derived from the control population. Intra- and interobserver variability were 7.0% and 7.7%, respectively. CONCLUSION: Our results suggest that combination of TDI and TSI with intrinsic plausibility control improves intra- and interobserver variability and allows easy and reliable assessment of cardiac asynchrony.


Assuntos
Bloqueio de Ramo/complicações , Bloqueio de Ramo/diagnóstico por imagem , Ecocardiografia/métodos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia , Algoritmos , Estudos de Viabilidade , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Europace ; 10(1): 53-8, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18037668

RESUMO

AIMS: Recommendations for programming the rate-adaptive AV delay in CRT. METHODS AND RESULTS: In cases of continual biventricular pacing, the optimal AV delay in CRT (AVD(opt)) is the net effect of the pacemaker-related interatrial conduction time (IACT), duration of the left-atrial electromechanical action (LA-EAC(long)), and the duration of the left-ventricular latency period (S(V)-EAC(short)). It can be calculated by AVD(opt) = IACT+LA-EAC(long)-S(V)-EAC(short). We measured these three components in 20 CRT-ICD patients during rest and submaximal ergo metric exercise (71 +/- 9 W) resulting in a 22.5 +/- 9.6 bpm rate increase. IACT and S(V)-EAC(short) did not reveal significant differences. LA-EAC(long), however, varied significantly by -10.7 +/- 16.1 ms (P = 0.008) during exercise. In contrast to AVD(optVDD), there was a significant difference in AVD(optDDD) of -8.8 +/- 14.5 ms (P = 0.014) between the resting and submaximal exercise conditions. In DDD pacing, AVD(opt) was shortened by 2.6 ms/10 bpm. CONCLUSION: In consideration of the findings of the studies performed to date, the rate-adaptive AV delay should be deactivated.


Assuntos
Estimulação Cardíaca Artificial/métodos , Cardiopatias/fisiopatologia , Marca-Passo Artificial , Idoso , Exercício Físico/fisiologia , Feminino , Átrios do Coração/fisiopatologia , Sistema de Condução Cardíaco/fisiologia , Cardiopatias/terapia , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Descanso/fisiologia , Fatores de Tempo
17.
Cardiovasc Ultrasound ; 6: 4, 2008 Jan 16.
Artigo em Inglês | MEDLINE | ID: mdl-18199315

RESUMO

BACKGROUND: Intraseptal hematoma and subsequent myocardial infarction due to accidental contrast agent deposition complicating diagnostic cineventriculography is a previously undescribed complication of angiography. CASE PRESENTATION: A 61 year old man was admitted at intensive care unit because of unstable angina pectoris 1 hour after coronary angiography. Transthoracic contrast echocardiography showed a non-perfused area in the middle of interventricular septum with an increase of thickening up to 26 mm. Review of cineventriculography revealed contrast enhancement in the interventricular septum after contrast medium injection and a dislocation of the pigtail catheter tip. Follow up by echocardiography and MRI showed, that intramural hematoma has resolved after 6 weeks. After 8 weeks successful stent implantation in LAD was performed and after 6 month the patient had a normal LV-function without ischemic signs or septal thickening demonstrated by stressechocardiography. CONCLUSION: A safe and mobile position of the pigtail catheter during ventriculography in the middle of the LV cavity should be ensured to avoid this potentially life-threatening complication. For assessment and absolute measurement of intramural hematoma contrast-enhanced echocardiography is more feasible than MRI and makes interchangeable results.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Meios de Contraste/efeitos adversos , Comunicação Interventricular/diagnóstico por imagem , Comunicação Interventricular/etiologia , Hematoma/etiologia , Infarto do Miocárdio/etiologia , Meios de Contraste/administração & dosagem , Ecocardiografia sob Estresse , Eletrocardiografia , Comunicação Interventricular/terapia , Hematoma/terapia , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/terapia , Radiografia , Stents
18.
Cardiovasc Ultrasound ; 6: 58, 2008 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-19032733

RESUMO

BACKGROUND: Cardiac resynchronization Therapy (CRT) is an effective therapy for chronic heart failure with beneficial hemodynamic effects leading to a reduction of morbidity and mortality. The responder rates, however, are low. There are various and contentious echocardiographic parameters of myocardial asynchrony. Patient selection by echocardiographic assessment of asynchrony is thought to improve responder rates. METHODS: In this small single-center pilot-study, seven established parameters of myocardial asynchrony were used to select patients for CRT: (1) interventricular electromechanical delay (IMD, cut-off > or = 40 ms), (2) Septal-to-posterior wall motion delay (SPWMD, > or = 130 ms), (3) maximal difference in time-to-peak velocities between any two of twelve LV segments (Ts-12 > or = 104 ms), (4) standard deviation of time to peak myocardial velocities (Ts-12-SD, > or = 34.4 ms), (5) difference between the septal and basal time-to-peak velocity (TDId, > or = 60 ms), (6) left ventricular electromechanical delay (LVEMD, > 140 ms) and (7) delayed longitudinal contraction (DLC, > 2 segments).16 chronic heart failure patients (NYHA III-IV, LVEF < 0.35, QRS > or = 120 ms) at least two out of seven parameters of myocardial asynchrony received cardiac resynchronization therapy (CRT-ICD). Follow-up echo examination was after 6 months. The control group was a historic group of CRT patients (n = 38) who had not been screened for echocardiographic signs of myocardial asynchrony prior to device implantation. RESULTS: Based on reverse remodeling (relative reduction of LVESV > 15%, relative increase of LVEF > 25%), the responder rate to CRT was 81.2% in patients selected for CRT according to our protocol as compared to 47.4% in the control group (p = 0.04). At baseline, there were on average 4.1 +/- 1.6 positive parameters of asynchrony (follow-up: 3.7 [+/- 1.6] parameters positive, p = 0.52). Only the LVEMD decreased significantly after CRT (p = 0.027). The remaining parameters showed a non-significant trend towards reduction of myocardial asynchrony. CONCLUSION: The implementation of different markers of asynchrony in the selection process for CRT improves the hemodynamic response rate to CRT.


Assuntos
Algoritmos , Estimulação Cardíaca Artificial , Ecocardiografia/métodos , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/prevenção & controle , Interpretação de Imagem Assistida por Computador/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/prevenção & controle , Idoso , Feminino , Humanos , Aumento da Imagem/métodos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Prognóstico , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resultado do Tratamento
20.
Sleep ; 29(9): 1197-202, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17040007

RESUMO

STUDY OBJECTIVES: We investigated the effect of 1 week of nocturnal overdrive pacing (NOP) on the apnea-hypopnea index (AHI) in patients with a chronically implanted pacemaker and diagnosed during a screening phase with sleep apnea. DESIGN: Randomized, single-blind, crossover study. SETTING: University medical centers in Zürich, Switzerland, and Berlin, Germany. PATIENTS: Nineteen patients with mild to severe sleep apnea/hypopnea (16 men, mean age = 68.8 +/- 11.4 years) participated. The individuals did not suffer from permanent atrial arrhythmia, did not use continuous positive airway pressure, and had been implanted with atrial or dual-chamber pacemakers. INTERVENTIONS: Nocturnal lower rates were 45 and 75 beats per minute (bpm) at night for the control and NOP arms, respectively, and daytime lower rates were 60 bpm. Subjects were in each arm for 1 week. MEASUREMENTS AND RESULTS: Heart-rate increase from control (61 +/- 9 bpm) to NOP (78 +/- 4 bpm) followed by significant reduction in circulation time (24.6 seconds control, 20.7 seconds NOP; p = .04) resulted in no significant change in AHI (26.8 +/- 17.1/h control, 23.0 +/- 16.7/h NOP; p = .49). Seven subjects characterized by a higher hypopnea index, less stage 1 and 2 sleep, and less slow-wave sleep improved at least 1 AHI severity level with NOP, mainly attributable to reduction of hypopneas. CONCLUSION: NOP over a period of 1 week followed by a reduction in circulation time did not improve AHI in patients with SA. Whether an improvement by 1 AHI severity level in a specific subset of patients reflects a true response remains to be elucidated by further studies.


Assuntos
Síndromes da Apneia do Sono/epidemiologia , Síndromes da Apneia do Sono/terapia , Pressão Positiva Contínua nas Vias Aéreas , Estudos Cross-Over , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/estatística & dados numéricos , Polissonografia/métodos , Índice de Gravidade de Doença , Método Simples-Cego , Sono REM/fisiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA