Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Med Phys ; 48(10): 6497-6507, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34529270

RESUMO

PURPOSE: Recent evaluations of a 3D iterative cone-beam computed tomography (iCBCT) reconstruction method available on Varian radiation treatment devices demonstrated that iCBCT provides superior image quality when compared to analytical Feldkamp-Davis-Kress (FDK) method. However, iCBCT employs statistical penalized likelihood (PL) that is known to be highly sensitive to inconsistencies due to physiological motion occurring during the acquisition. We propose a computationally inexpensive extension of iCBCT addressing this deficiency. METHODS: During the iterative process, the gradients of PL are modified to avoid the generation of motion-related artifacts. To assess the impact of this modification, we propose a motion simulation generating CBCT projections of a moving anatomy together with artifact-free images used as ground truth. Contrast-to-noise ratio and power spectra of difference images are computed to quantify the impact of the motion on reconstructed CBCT volumes as well as the effect of the proposed modification. RESULTS: Using both simulated and clinical data, it is shown that the motion of patient's abdominal wall during the acquisition results in artifacts that can be quantified as low-frequency components in volumes reconstructed with iCBCT. Further, a quantitative evaluation demonstrates that the proposed modification of PL reduces these low-frequency components. While preserving the advantages of PL, it effectively suppresses the propagation of motion-related artifacts into clinically important regions, thus increasing the motion resiliency of iCBCT. CONCLUSIONS: The proposed modified iterative reconstruction method significantly improves the quality of CBCT images of anatomies suffering from residual motion.


Assuntos
Radioterapia Guiada por Imagem , Tomografia Computadorizada de Feixe Cônico Espiral , Algoritmos , Artefatos , Tomografia Computadorizada de Feixe Cônico , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas
2.
Med Phys ; 45(5): 1914-1925, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29509973

RESUMO

PURPOSE: To correct for scatter in kV cone-beam CT (CBCT) projection data on a clinical system using a new tool, Acuros® CTS, that estimates scatter images rapidly and accurately by deterministically solving the linear Boltzmann transport equation. METHODS: Phantom and patient CBCT scans were acquired on TrueBeam® radiotherapy machines. A first-pass reconstruction was used to create water and bone density maps of the imaged object, which was updated to include a more accurate representation of the patient couch. The imaging system model accounted for the TrueBeam x-ray source (polychromatic spectrum, beam filtration, bowtie filter, and collimation hardware) and x-ray detection system (antiscatter grid, flat-panel imager). Acuros CTS then used the system and object models to estimate the scatter component of each projection image, which was subtracted from the measured projections. The corrected projections were then reconstructed to produce the final result. We examined the tradeoff between run time and accuracy using a Pareto optimization of key parameters, including the voxel size of the down-sampled object model, the number of pixels in the down-sampled detector, and the number of scatter images (angular down-sampling). All computations and reconstructions were performed on a research workstation containing two graphics processing units (GPUs). In addition, we established a method for selecting a subset of projections for which scatter images were calculated. The projections were selected to minimize interpolation errors in the remaining projections. Image quality improvement was assessed by measuring the accuracy of the reconstructed phantom and patient images. RESULTS: The Pareto optimization yielded a set of parameters with an average run time of 26 seconds for scatter correction while maintaining high accuracy of scatter estimation. This was achieved in part by means of optimizing the projection angles that were processed, thus favoring the use of more angles in the lateral (i.e., horizontal) direction and fewer angles in the AP direction. In a 40 cm solid water phantom reconstruction, nonuniformities were decreased from 217 HU without scatter correction to 51 HU with conventional (kernel-based) scatter correction to 17 HU with Acuros CTS-based scatter correction. In clinical pelvis scans, nonuniformities in the bladder were reduced from 85 HU with conventional scatter correction to 14 HU with Acuros CTS. CONCLUSIONS: Acuros CTS is a promising new tool for fast and accurate scatter correction for CBCT imaging. By carefully modeling the imaging chain and optimizing several parameters, we achieved high correction accuracies with computation times compatible with the clinical workflow. The improvement in image quality enables better soft-tissue visualization and potentially enables applications such as adaptive radiotherapy.


Assuntos
Algoritmos , Processamento de Imagem Assistida por Computador/métodos , Modelos Teóricos , Espalhamento de Radiação , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA