1.
Cardiovasc Ultrasound ; 19(1): 22, 2021 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-34116696

RESUMO

BACKGROUND: Left atrial (LA) function can be impaired by the atrial fibrillation (AF) ablation and might be associated with the risk of recurrence. We sought to determine whether the post-procedural changes in LA function impact the risk of recurrence following AF ablation. METHODS: We retrospectively reviewed patients who underwent AF ablation between 2009 and 2011 and underwent transthoracic echocardiography before ablation, 1-day and 3-month after ablation. Peak left atrial contraction strain (PACS) and left atrial emptying fraction (LAEF) were evaluated during sinus rhythm and compared across the three time points. The primary endpoint was atrial tachyarrhythmia recurrence after ablation. RESULTS: A total of 144 patients were enrolled (mean age 61 ± 11 years, 77% male, 46% persistent AF). PACS and LAEF initially decreased 1-day following ablation but partially recovered within 3 months in PAF patients, with a similar trend in the PerAF patients. After median 24 months follow-up, 68 (47%) patients had recurrence. Patients with recurrence had higher PACS1-day than that in non-recurrence subjects (-10.9 ± 5.0% vs. -13.4 ± 4.7%, p = 0.003). PACS1-day -12% distinguished recurrence cases with a sensitivity of 67.7% and specificity of 60.5%. The Kaplan-Meier curves showed significant difference in 5-year cumulative probability of recurrence between those with PACS ≥ -12% and PACS < -12% (log rank p < 0.0001). Multivariate regression showed that PACS1-day was an independent risk factor of arrhythmia recurrence. CONCLUSIONS: Left atrial function deteriorates immediately following AF ablation and partially recovers in 3 months but remains abnormal in the majority of patients. PACS1-day post procedure predicts arrhythmia recurrence at long-term follow-up.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Feminino , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
2.
Echocardiography ; 36(7): 1397-1400, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31209920

RESUMO

We describe a case of a mass-like echocardiographic density on a mechanical prosthetic aortic valve. We initially suspected a thrombus vs vegetation on transthoracic echocardiography, but after transesophageal echocardiography, the density was subsequently determined to be cavitation by reviewing the initial images in slow motion.


Assuntos
Valva Aórtica/diagnóstico por imagem , Ecocardiografia/métodos , Próteses Valvulares Cardíacas , Microbolhas , Trombose Coronária/diagnóstico por imagem , Diagnóstico Diferencial , Humanos , Masculino , Pessoa de Meia-Idade , Estresse Mecânico
3.
BMC Cardiovasc Disord ; 18(1): 241, 2018 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-30579333

RESUMO

BACKGROUND: Noninvasive diagnosis of allograft rejection in heart transplant recipients is challenging. The utility of 2-dimensional speckle-tracking echocardiography (2D-STE) to predict severe rejection in heart transplant recipients with preserved left ventricular ejection fraction (LVEF) was evaluated. METHODS: Adult heart transplant patients with preserved LVEF (> 55%) and severe rejection by biopsy (Rejection Grade ≥ 2R) or no rejection between 1997 and 2011 at the Mayo Clinic in Rochester, Minnesota were evaluated. Transthoracic echocardiography was performed within 1 month of the biopsy. LV global longitudinal and circumferential strain and strain rates (GLS, GLSR, GCS, and GCSR) were analyzed retrospectively. RESULTS: Of 65 patients included, 25 had severe rejection and 40 were normal transplant controls without rejection. Both groups had more men than women (64 and 75%, respectively). Baseline clinical variables were similar between the groups. Both groups had normal LVEF (64.3% vs 64.5%; P = .87). All non-strain echocardiographic variables were similar between the 2 groups. Strain analysis showed significantly increased early diastolic longitudinal strain rate (P = .02) and decreased GCS (P < .001) and GCSR (P = .02) for the rejection group compared with the control group. The area under the receiver operating characteristic curve for GCS was 0.77. With a GCS cutoff of - 17.60%, the sensitivity and specificity of GCS to detect severe acute rejection were 81.8 and 68.4%, respectively. CONCLUSIONS: 2D-STE may be useful in detecting severe transplant rejection in heart transplant patients with normal LVEF.


Assuntos
Ecocardiografia/métodos , Rejeição de Enxerto/diagnóstico por imagem , Transplante de Coração/efeitos adversos , Coração/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda , Adulto , Biópsia , Bases de Dados Factuais , Feminino , Rejeição de Enxerto/fisiopatologia , Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Minnesota , Variações Dependentes do Observador , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Sístole , Fatores de Tempo , Resultado do Tratamento
4.
Am Heart J ; 170(5): 914-22, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26542499

RESUMO

BACKGROUND: Left atrial appendage emptying flow velocity (LAAEV) depends largely on left atrioventricular compliance and may play a role in mediating the perpetuation of atrial fibrillation (AF) and AF-related outcomes. METHODS: We identified 3,251 consecutive patients with sustained AF undergoing first-time successful transesophageal echocardiography (TEE)-guided electrical cardioversion who were enrolled in a prospective registry between May 2000 and March 2012. Left atrial appendage emptying flow velocity was stratified into quartiles: ≤20.2, 20.3-33.9, 34-49.9, and ≥50 cm/s. Multivariate Cox regression models were used to identify independent predictors of AF recurrence, ischemic stroke, and all-cause mortality. RESULTS: The mean (SD) age was 69 (12.6) years and 67% were men. Compared with the fourth quartile, patients in the first-third quartiles were significantly older, had higher CHA2DS2-VASc (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, stroke/transient ischemic attack [TIA], vascular disease, age 65-74 years, sex category) scores, greater frequency of atrial spontaneous echo contrast, and AF of longer duration. Kaplan-Meier analysis showed a decreased probability of event-free survival with decreasing quartiles of LAAEV. Five-year cumulative event rates across first-fourth quartiles were 83%, 80%, 73%, and 73% (P < .001) for first AF recurrence; 7.5%, 7.0%, 4.1%, and 4.0%, for stroke (P = .01); and 31.3%, 26.1%, 24.1%, and 19.4%, for mortality (P < .001), respectively. Multivariate Cox regression analysis revealed an independent association of the first and second quartiles with AF recurrence (P < .001 and P < .001, respectively) and stroke (P = .03, and P = .04, respectively), and of the first quartile with mortality (P = .003). CONCLUSIONS: Patients with decreased LAAEV have an increased risk of AF recurrence, stroke, and mortality after successful electrical cardioversion. Real-time measurement of LAAEV by TEE may be a useful physiologic biomarker for individualizing treatment decisions in patients with AF.


Assuntos
Apêndice Atrial/fisiopatologia , Fibrilação Atrial/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Cardioversão Elétrica , Monitorização Fisiológica/métodos , Acidente Vascular Cerebral/epidemiologia , Idoso , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/terapia , Intervalo Livre de Doença , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Estudos Prospectivos , Recidiva , Acidente Vascular Cerebral/etiologia , Taxa de Sobrevida/tendências , Estados Unidos/epidemiologia
5.
J Am Soc Echocardiogr ; 35(7): 682-691.e2, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35158051

RESUMO

BACKGROUND: Bioprosthetic aortic valve dysfunction (BAVD) is a challenging diagnosis. Commonly used algorithms to classify high-gradient BAVD are the 2009 American Society of Echocardiography, 2014 Blauwet-Miller, and 2016 European Association of Cardiovascular Imaging algorithms. We sought (1) to evaluate the accuracy of existing algorithms against objectively proven BAVD and (2) to propose an improved algorithm. METHODS: This was a retrospective study of 266 patients with objectively proven BAVD (pathology of explanted valves, four-dimensional computed tomography prior to transcatheter valve-in-valve replacement, or therapeutically confirmed bioprosthetic thrombosis) who were treated. Of those, 191 had obstruction, 48 had regurgitation, 15 had mixed stenosis and regurgitation, and 12 had patient-prosthesis mismatch (PPM). Normal controls were matched 1:1 (age, prosthesis size, and type), of which 43 had high gradients (PPM in 30, high flow in nine, and normal prosthesis in nine). Algorithm assignment was based on the echocardiogram leading to BAVD diagnosis and the predischarge "fingerprint" echocardiogram after surgical or transcatheter aortic valve replacement. A novel algorithm (Mayo Clinic algorithm) incorporating valve appearance in addition to Doppler parameters was developed to improve observed deficiencies. RESULTS: The accuracy of existing algorithms was suboptimal (2009 American Society of Echocardiography, 62%; 2014 Blauwet-Miller, 62%; 2016 European Association of Cardiovascular Imaging, 57%). The most common overdiagnosis was PPM (22%-29% of patients and controls with high gradients). The novel Mayo Clinic algorithm correctly identified the mechanism in 256 of 307 patients and controls (83%). Recognition of regurgitation was substantially improved (42 of 47 patients, 89%), and the number of PPM misdiagnoses was significantly reduced (five patients). CONCLUSION: Currently recommended algorithms misclassify a significant number of BAVD patients. The accuracy was improved by a newly proposed algorithm.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Algoritmos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Ecocardiografia , Humanos , Desenho de Prótese , Estudos Retrospectivos
6.
Circulation ; 121(12): 1423-31, 2010 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-20231533

RESUMO

BACKGROUND: Mitral annulus is a complex structure of poorly understood physiology. Full-volume real-time 3-dimensional transesophageal echocardiography offers a unique opportunity to completely image and quantify mitral annulus size and motion. METHODS AND RESULTS: Real-time 3-dimensional transesophageal echocardiography of the mitral valve was acquired in 32 patients with myxomatous valve disease (MVD) and moderate to severe regurgitation, 15 normal control subjects, and 10 patients with ischemic mitral regurgitation of identical body surface area. Mitral annular dimensions (circumference, area, anteroposterior and intercommissural diameters, height, and ratio of height to intercommissural diameter ratio, which appraises annular saddle-shape depth) were measured throughout the cardiac cycle with dedicated quantification software. Compared with direct surgical measurement, 3-dimensional anterior annular dimension provided reliable measurements (mean difference, 0.1+/-0.1 mm; P=0.73; 95% confidence interval, +/-4.4 mm). Annular dimensions were larger in MVD patients compared with control subjects in diastole (all P<0.05). Normal annulus displayed early-systolic anteroposterior (P<0.001) and area (P=0.04) contraction, increased height (P<0.001), and deeper saddle shape (ratio of height to intercommissural diameter, 15+/-1% to 21+/-1%; P<0.001), whereas intercommissural diameter was unchanged (P=0.30). In contrast, MVD showed early-systolic intercommissural dilatation (P=0.02) and no area contraction (P=0.99), height increase (P=0.11), or saddle-shape deepening (P=0.35). Late-systolic MVD annular saddle shape deepened but annular area excessively enlarged (P<0.04) as a result of persistent intercommissural widening (P<0.02). MVD annulus also contrasts with ischemic mitral regurgitation annulus, which, despite similar anteroposterior enlargement, is narrower and essentially adynamic. After MVD repair, the annulus remained dynamic without systolic saddle-shape accentuation (P=0.30). CONCLUSIONS: Real-time 3-dimensional transesophageal echocardiography provides insights into normal, dynamic mitral annulus function with early-systolic area contraction and saddle-shape deepening contributing to mitral competency. MVD annulus is also dynamic but considerably different with loss of early-systolic area contraction and saddle-shape deepening despite similar magnitude of ventricular contraction, suggestive of ventricular-annular decoupling. Subsequent area enlargement may contribute to mitral incompetence. After mitral repair, MVD annulus remains dynamic without systolic saddle-shape accentuation. Thus, real-time 3-dimensional transesophageal echocardiography provides new insights that allow the refining of mitral pathophysiology concepts and repair strategies.


Assuntos
Insuficiência da Valva Mitral/patologia , Valva Mitral/patologia , Idoso , Estudos de Casos e Controles , Diástole , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Movimento (Física) , Software
7.
Circulation ; 117(20): 2617-25, 2008 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-18474810

RESUMO

BACKGROUND: Several echocardiographic dyssynchrony indexes have been proposed to identify responders to cardiac resynchronization therapy using tissue velocity and strain. The present study aimed to compare tissue velocity-derived and strain-derived dyssynchrony indexes in patients with or without systolic dysfunction and left bundle-branch block. METHODS AND RESULTS: Tissue Doppler imaging was performed in 120 subjects divided into 4 groups: group 1 (n=40), normal subjects; group 2 (n=20), normal left ventricular ejection fraction and left bundle-branch block; group 3 (n=20), left ventricular ejection fraction <35% and normal conduction; and group 4 (n=40), left ventricular ejection fraction <35% and left bundle-branch block. Dyssynchrony indexes based on time to peak tissue velocity (septal-lateral delay, anteroseptal-posterior delay, and SD in time to peak systolic velocity in the 12 left ventricular segments) and strain (SD of time to peak strain in 12 segments) were measured. The SD in time to peak systolic velocity in the 12 left ventricular segments was greater in group 4 (54 ms; 25th and 75th percentiles, 46 to 64 ms) than group 1 (44 ms; 25th and 75th percentiles, 28 to 53 ms; P=0.006), but there was a considerable overlap of all tissue velocity-derived indexes among 4 groups, with 40% to 68% of group 1 having values proposed for predicting the responders of cardiac resynchronization therapy. The SD of time to peak strain in 12 segments distinguished these groups with much less overlap (P<0.01 for all pairwise comparisons). CONCLUSIONS: A substantial proportion of normal subjects have tissue velocity-derived dyssynchrony indexes higher than the cutoff value proposed for predicting beneficial effect of cardiac resynchronization therapy. Strain-derived timing index appears to be more specific for dyssynchrony in patients with systolic dysfunction and left bundle-branch block. Identifying an optimal tissue velocity- or strain-derived dyssynchrony index requires a large prospective clinical trial.


Assuntos
Estimulação Cardíaca Artificial , Ecocardiografia/normas , Insuficiência Cardíaca/diagnóstico , Valor Preditivo dos Testes , Remodelação Ventricular , Adulto , Bloqueio de Ramo , Ecocardiografia/métodos , Feminino , Insuficiência Cardíaca/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Prognóstico , Índice de Gravidade de Doença , Sístole
8.
Am Heart J ; 157(4): 762.e3-10, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19332207

RESUMO

BACKGROUND: Functional mitral regurgitation (MR) is commonly seen in dilated cardiomyopathy (DCM), which may result from left ventricular (LV) dilatation and alteration in the geometric relationship of mitral valve apparatus. However, not all patients with DCM show significant MR and left atrial (LA) enlargement. The aim of this study was to assess responsible factors for developing mitral valve regurgitation. METHODS: Of 300 patients enrolled in the Acorn trial, baseline echocardiography studies were available in 288, of whom 144 were excluded because of a variety of reasons. Echocardiographic data were examined for the remaining 144 patients in sinus rhythm with DCM, but without organic mitral valve disease and ischemic heart disease. Mitral regurgitation was assessed by color-flow imaging. All echocardiographic parameters were indexed to body surface area. RESULTS: Of 144 patients, 87 had MR grade > or =2 (group 1) and 57 had MR grade 0 or +1 (group 2). Group 1 had larger tenting area, tenting height, tethering distance, LA volume index, and mitral annular area than group 2 (all P < .001); LV volume index and ejection fraction were similar between groups. The major determinant of MR severity was tenting area (r = 0.49, P < .001), and this was best related to mitral annular area (r = 0.85, P < .001). Mitral annular area was most strongly associated with LA volume (r = 0.56, P < .001). In addition, LA volume index was highly correlated with LV diastolic dysfunction (r = 0.58, P < .001), both in total and in group 2 only. CONCLUSIONS: For patients with DCM in the Acorn trial, MR severity was associated with LA volume and mitral annular area but not with LV volume. Mitral annular area and LA volume were closely related, even in patients without significant MR. These findings suggest that LA enlargement caused by advanced diastolic dysfunction may contribute to causing significant MR by augmenting mitral annular dilatation in DCM.


Assuntos
Função do Átrio Esquerdo/fisiologia , Cardiomiopatia Dilatada/fisiopatologia , Átrios do Coração/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Cardiomiopatia Dilatada/diagnóstico por imagem , Cardiomiopatia Dilatada/etiologia , Diástole , Ecocardiografia Doppler em Cores , Feminino , Seguimentos , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico por imagem , Prognóstico , Índice de Gravidade de Doença
9.
Struct Heart ; 3(4): 302-308, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32984753

RESUMO

BACKGROUND: This study examined the impact of mitral valve repair (MVRe) on survival of patients with moderate or severe (≥2+) MR and ischemic cardiomyopathy randomized to coronary artery bypass grafting (CABG) versus CABG+surgical ventricular reconstruction (SVR) in the STICH trial. METHODS: Among patients with moderate or severe MR and ischemic cardiomyopathy undergoing CABG or CABG+SVR, the impact of MVRe on mortality between the two treatment arms was compared. RESULTS: Among 867 patients with assessment of baseline MR severity, 211 had moderate or severe MR. After excluding 7 patients who underwent mitral valve replacement, 50, 44, 62, and 48 patients underwent CABG, CABG+MVRe, CABG+SVR, and CABG+SVR+MVRe, respectively. Four-year mortality rates were lower following CABG+MVRe than CABG alone (16% vs. 55%; adjusted hazard ratio [HR] 0.30; 95% CI 0.13-0.71). In contrast, the CABG+SVR+MVRe and CABG+SVR groups had similar 4-year mortality of 39% vs. 39% (adjusted HR 0.88; 95% CI 0.46-1.70). MVRe had a more favorable effect on survival in patients undergoing CABG alone compared to CABG+SVR (p=0.013). Baseline MR severity was similar between patients that received CABG+MVRe and those that underwent CABG+SVR+MVRe. A larger proportion of patients demonstrated a reduction in MR between 4 and 24 months after CABG+MVRe compared to CABG+SVR+MVRe (50.0% versus 25.0%, p=0.023). CONCLUSION: In patients with moderate or severe MR and ischemic cardiomyopathy undergoing CABG, MVRe appears to have a favorable effect on survival. The addition of SVR to CABG may attenuate the anticipated benefits of MVRe by limiting the long-term reduction of MR with MVRe.

10.
Am J Cardiol ; 101(7): 1039-45, 2008 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-18359328

RESUMO

We examined the potential role of Doppler myocardial imaging for early detection of systolic dysfunction in patients with systemic amyloidosis (AL) but without evidence of cardiac involvement by standard echocardiography. We identified 42 patients without 2-dimensional echocardiographic or Doppler evidence of cardiac involvement. These patients had normal ventricular wall thickness and normal velocity of the medial mitral annulus. Myocardial images were obtained in these patients and in 32 age- and gender-matched healthy controls. Peak longitudinal systolic tissue velocity (sTVI), systolic strain rate (sSR), and systolic strain (sS) were determined for 16 left ventricular segments. Radial and circumferential sSR and sS were also measured. Compared with controls in this group of patients with AL, peak longitudinal sSR (-1.0 +/- 0.2 vs -1.4 +/- 0.2, p <0.001) and peak longitudinal sS (-15.6 +/- 3.3 vs -22.5 +/- 2.0 p <0.001) were significantly decreased. In conclusion, the mean sS from all 6 basal segments, or from all 16 left ventricular segments differentiated patients with AL with normal echocardiography from controls, with similar accuracy for the mean sSR from the 6 basal segments. This distinction was not apparent from peak longitudinal sTVI or from radial or circumferential sSI or sSR.


Assuntos
Amiloidose/diagnóstico por imagem , Ecocardiografia Doppler/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Idoso , Amiloidose/complicações , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sístole , Disfunção Ventricular Esquerda/etiologia
11.
J Am Soc Echocardiogr ; 31(12): 1353-1365, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30340892

RESUMO

In the 1970s, as cardiac imaging matured from M-mode to two-dimensional echocardiography, investigators in Norway showed that continuous-wave Doppler ultrasonography could be used to accurately measure the mean gradient and pressure half-time for stenotic mitral valves. In the 1980s, continuous-wave Doppler was validated for measurement of the pressure gradient across stenotic aortic valves, and pulsed-wave Doppler combined with two-dimensional echocardiographic imaging was validated for noninvasive measurement of stroke volume and cardiac output. The combination of stroke volume measurement and measurement of the time-velocity integral of flow through the aortic valve was then validated as a means to accurately calculate valve area for patients with stenotic aortic valves or aortic prostheses. This integration of cardiac Doppler ultrasonography with two-dimensional echocardiographic cardiac imaging led to a revolution in noninvasive hemodynamic evaluations, which have replaced invasive hemodynamic evaluations in surgical decision making for most patients with native or prosthetic valvular stenosis.


Assuntos
Estenose da Valva Aórtica/história , Ecocardiografia Doppler/história , Hemodinâmica , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Velocidade do Fluxo Sanguíneo , História do Século XX , Humanos
12.
Am J Cardiol ; 122(6): 1068-1073, 2018 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-30075888

RESUMO

We sought to characterize mid-ascending aorta diameter reference values by age, sex, and body surface area (BSA) in a large echocardiography laboratory practice-based cohort. All subjects with transthoracic echocardiograms with mid-ascending aorta diameter measure from January 2004 to December 2009 were identified, and medical records were reviewed for medical history and anthropometric data. Those with aortic valve disease or replacement, congenital heart disease, any connective tissue or inflammatory disease that may affect the aorta, or known aortic aneurysm (>55 mm) were excluded. Mid-ascending aorta diameter was measured in a standardized manner using "leading edge to leading edge" technique at end-diastole. Of 27,839 eligible subjects, 16,620 did not have history of hypertension and were included in the analysis (56.3% female; mean age 52.0 ± 15.8 years), mean mid-ascending aorta diameter 31.7 ± 4.1 mm. Females had smaller diameter than males (30.5 ± 3.7 mm vs 33.3 ± 4.0 mm; p <0.001). Subjects with history of hypertension (n = 11,219; not included in the analysis) had larger mid-ascending aorta diameter compared with normotensive subjects (33.9 ± 3.8 mm vs 31.7 ± 4.1 mm; p < 0.001). Age had the greatest correlation with aortic size (r = 0.55), followed by sex (r = 0.35) and BSA (r = 0.35). Nomograms for predicted mid-ascending aorta diameter were generated at the 95th percentile using quantile regression for subjects without hypertension stratified by age, sex, and BSA. In conclusion, mid-ascending aorta diameter is predominantly associated with sex, age, and BSA. The nomograms established by this study may serve as useful reference values for echocardiographic screening and surveillance.


Assuntos
Aorta/diagnóstico por imagem , Ecocardiografia , Adulto , Fatores Etários , Idoso , Antropometria , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nomogramas , Valores de Referência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores Sexuais
13.
Circulation ; 113(3): 420-6, 2006 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-16415379

RESUMO

BACKGROUND: The impact of aortic prosthesis-patient mismatch (P-PtM) on long-term survival is unclear. METHODS AND RESULTS: Between 1985 and 2000, 388 patients at Mayo Clinic in Rochester, Minn, underwent aortic valve replacement (AVR) with 19- or 21-mm St Jude Medical prostheses and had transthoracic echocardiography within 1 year after AVR. Mean age of patients was 62+/-13 years; 69% were female. Prosthesis effective orifice area (EOA) was derived from the continuity equation. P-PtM was classified as severe (indexed EOA < or =0.60 cm2/m2), moderate (0.60 cm2/m20.85 cm2/m2). P-PtM was severe in 66 patients (17%), moderate in 168 (43%), and not hemodynamically significant in 154 (40%). Patients with severe P-PtM had a significantly larger body surface area (P<0.0001), higher mean gradient (P<0.0001), lower preoperative (P<0.0001) and postoperative (P<0.0001) ejection fractions, and lower stroke volume (P<0.0001) and more often received a 19-mm prosthesis (P=0.0008) than patients with moderate or no hemodynamically significant mismatch. For patients with severe mismatch, 5-year survival rates (72+/-6%) and 8-year survival rates (41+/-8%) were significantly less than for patients with moderate mismatch (80+/-3% and 65+/-5%; P=0.026) or no hemodynamically significant mismatch (85+/-3% and 74+/-5%; P=0.002). On multivariate analysis after adjustment for other predictors of outcome, severe mismatch was associated with higher mortality (hazard ratio 2.18; 95% confidence interval 1.24 to 3.85; P=0.007) and higher incidence of congestive heart failure (hazard ratio 3.1; 95% confidence interval 1.3 to 7.4; P=0.009) than no hemodynamically significant mismatch. CONCLUSIONS: Severe P-PtM is an independent predictor of higher long-term mortality and congestive heart failure in patients with small St Jude Medical aortic valve prostheses. For patients undergoing AVR who are at risk of severe mismatch, every effort should be made to use a larger prosthesis or to consider a prosthesis with a larger EOA.


Assuntos
Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas/estatística & dados numéricos , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/cirurgia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/mortalidade , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Fatores de Risco
14.
Int J Cardiovasc Imaging ; 33(5): 615-621, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28004210

RESUMO

Mitral annular calcification (MAC) is a chronic, progressive process characterized by calcium deposition on the mitral valve annulus. There is no current grading system to relay the severity of MAC. The primary purpose of this study was to investigate the extreme end of the severity spectrum in order to describe "exuberant mitral annular calcification", and a retrospective chart review of all patients with exuberant mitral annulus calcification evaluated at Mayo Clinic Rochester between January 1996 and December 2014 was performed. This is the first study to define criteria of "exuberant mitral annular calcification", emphasizing the importance of identifying the extreme degree of mitral annular calcification.


Assuntos
Calcinose/diagnóstico por imagem , Técnicas de Imagem Cardíaca , Doenças das Valvas Cardíacas/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Calcinose/mortalidade , Calcinose/fisiopatologia , Calcinose/cirurgia , Doença Crônica , Ecocardiografia Doppler , Ecocardiografia Tridimensional , Feminino , Doenças das Valvas Cardíacas/mortalidade , Doenças das Valvas Cardíacas/fisiopatologia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Humanos , Masculino , Prontuários Médicos , Pessoa de Meia-Idade , Minnesota , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Valor Preditivo dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Resultado do Tratamento
15.
Am J Cardiol ; 120(8): 1373-1380, 2017 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-28826894

RESUMO

This study aimed to investigate the utility of transthoracic echocardiographic (TTE) Doppler-derived parameters in detection of mitral prosthetic dysfunction and to define optimal cut-off values for identification of such dysfunction by valve type. In total, 971 TTE studies (647 mechanical prostheses; 324 bioprostheses) were compared with transesophageal echocardiography for evaluation of mitral prosthesis function. Among all prostheses, mitral valve prosthesis (MVP) ratio (ratio of time velocity integral of MVP to that of left ventricular outflow tract; odds ratio [OR] 10.34, 95% confidence interval [95% CI] 6.43 to 16.61, p<0.001), E velocity (OR 3.23, 95% CI 1.61 to 6.47, p<0.001), and mean gradient (OR 1.13, 95% CI 1.02 to 1.25, p=0.02) provided good discrimination of clinically normal and clinically abnormal prostheses. Optimal cut-off values by receiver operating characteristic analysis for differentiating clinically normal and abnormal prostheses varied by prosthesis type. Combining MVP ratio and E velocity improved specificity (92%) and positive predictive value (65%) compared with either parameter alone, with minimal decline in negative predictive value (92%). Pressure halftime (OR 0.99, 95% CI 0.98 to 1.00, p=0.04) did not differentiate between clinically normal and clinically abnormal prostheses but was useful in discriminating obstructed from normal and regurgitant prostheses. In conclusion, cut-off values for TTE-derived Doppler parameters of MVP function were specific to prosthesis type and carried high sensitivity and specificity for identifying prosthetic valve dysfunction. MVP ratio was the best predictor of prosthetic dysfunction and, combined with E velocity, provided a useful parameter for determining likelihood of dysfunction and need for further assessment.


Assuntos
Bioprótese/efeitos adversos , Velocidade do Fluxo Sanguíneo/fisiologia , Próteses Valvulares Cardíacas/efeitos adversos , Insuficiência da Valva Mitral/fisiopatologia , Valva Mitral/fisiopatologia , Função Ventricular Esquerda/fisiologia , Ecocardiografia Doppler , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Desenho de Prótese , Falha de Prótese , Estudos Retrospectivos , Fatores de Tempo
16.
Am J Cardiol ; 98(12): 1581-6, 2006 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-17145214

RESUMO

We investigated the influence of > or =70% luminal coronary artery stenosis on regional diastolic deformation at rest using 2-dimensional strain echocardiography. We prospectively imaged patients during/within 24 hours of coronary angiography. Longitudinal systolic (SRs), early (SRe), and late diastolic strain rates, systolic, early, and late diastolic strain and times to isovolumic relaxation and peak SRe were measured in the 3 major vascular territories. Regions subtended by > or =70% coronary stenosis were labeled ischemic. Ischemic regions were compared with the same region in patients without significant coronary stenosis. Of 61 enrolled patients (38 men), 39 had > or =70% coronary stenosis (1 vessel in 14, 2 vessels in 15, 3 vessels in 10), and 15 had normal coronary arteries. There were no significant differences between the normal and ischemic groups with regard to age (59 +/- 13 vs 64 +/- 10 years, p = 0.20), clinical variables (dyslipidemia, smoking, diabetes), systolic (130 +/- 26 vs 139 +/- 31 mm Hg, p = 0.38) or diastolic (72 +/- 13 vs 72 +/- 11 mm Hg, p = 0.81) blood pressure and ejection fraction (58 +/- 12% vs 56 +/- 11%, p = 0.66). SRs and SRe were significantly decreased in ischemic compared with normal regions in all vascular distributions. SRs and SRe together (values below cutoff) or SRe alone were the most specific (93%) and SRe or SRs below cutoff the most sensitive (93%) parameters for detecting ischemic regions. In conclusion, analysis of regional deformation by 2-dimensional strain echocardiography enables detection of significantly diseased coronary arteries at rest. Altered diastolic deformation at rest identifies regions subtended by > or =70% coronary stenosis with high specificity.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Ecocardiografia , Função Ventricular Esquerda , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/fisiopatologia , Diástole , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia
17.
Am J Cardiol ; 97(6): 866-71, 2006 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-16516591

RESUMO

We sought to determine whether the echocardiographic Doppler parameters of left ventricular diastolic dysfunction predict future heart failure (HF) events and, if so, which parameters best predict HF. We also examined whether the predictive ability of echocardiographic Doppler parameters was related to their prediction of left ventricular end-diastolic pressure (LVEDP). We studied patients who underwent cardiac catheterization and echocardiography performed within a 30-day period. The end point was HF, defined as new-onset or recurrent HF diagnosed by a physician and requiring the initiation or modification of treatment of HF. We identified 289 patients (mean age 63.5 +/- 12.6 years) with a mean follow-up of 10.9 +/- 10.2 months. A total of 24 HF events occurred. LVEDP was a significant predictor of HF univariately and independently in multiple regression models after adjustment for ejection fraction. In Cox models adjusted for age, gender, LVEDP, and ejection fraction, only the left atrial volume index and early mitral inflow to early diastolic tissue velocity (E/e') ratio remained predictive of HF. A multiple regression model, including all echocardiographic variables, showed a persistent, although attenuated, relation of early to late mitral inflow velocity (E/A) ratio and E/e' with LVEDP (p = 0.06 and p = 0.002, respectively). The addition of E/e' or the left atrial volume indexed to body surface area, but not E/A, to the clinical history and left ventricular ejection fraction provided incremental prognostic information. A LVEDP of > or =20 mm Hg, E/e' ratio of > or =15, and left atrial volume index of > or =23 ml/m(2) identified those with a higher risk of HF. In conclusion, invasively determined LVEDP is an independent predictor of future HF events. E/e' and the left atrial volume indexed to body surface area are the best independent predictors of future HF and provide prognostic information incremental to the clinical history and left ventricular ejection fraction.


Assuntos
Ecocardiografia Doppler em Cores/métodos , Insuficiência Cardíaca/diagnóstico , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda/fisiologia , Adulto , Idoso , Vasos Coronários/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Estudos Retrospectivos , Volume Sistólico/fisiologia
18.
Mayo Clin Proc ; 81(6): 777-82, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16770978

RESUMO

OBJECTIVE: To determine the echocardiographic changes in the heart at 3 months and 1 year after pulmonary thromboendarterectomy (PTE) in patients with chronic thromboembolic pulmonary hypertension (CTEPH). PATIENTS AND METHODS: Thirty-two adult patients who underwent PTE for CTEPH at the Mayo Clinic in Rochester, Minn, from 1997 to 2003 were included in the study. All underwent transthoracic echocardiography before surgery. Follow-up echocardiography was performed within 3 months of surgery in 28 patients and 1 year postoperatively in 17 patients. The results were compared with baseline data. RESULTS: Within 3 months after PTE, the right ventricular end-diastolic area decreased from 38.4 +/- 12.8 cm2 to 32.5 +/- 10.4 cm2 (mean difference, 5.8 +/- 10.4 cm2; P = .02). The right ventricular end-systolic area decreased from 30.4 +/- 12.1 cm2 to 24.1 +/- 8.6 cm2 (mean difference, 6.3 +/- 10.1 cm2; P = .008). The right ventricular systolic pressure decreased significantly from 92.6 +/- 22.0 mm Hg to 55.0 +/- 19.8 mm Hg (mean difference, 40.0 +/- 24.8 mm Hg; P < .001). Tricuspid regurgitation (TR) improved from a mean grade of 2.5 +/- 1.2 to 1.2 +/- 1.1 (mean difference, 1.5 +/- 1.0; P < .001). At 12 months, the right ventricular end-diastolic area, right ventricular end-systolic area, right ventricular systolic pressure, and TR also were significantly lower than baseline values. CONCLUSION: In patients with CTEPH who undergo PTE, echocardiographic measurements of right ventricular size, systolic pressure, and TR show significant improvement immediately after surgery, which is sustained for up to 1 year after surgery.


Assuntos
Ecocardiografia Doppler , Endarterectomia , Hipertensão Pulmonar/diagnóstico por imagem , Hipertensão Pulmonar/cirurgia , Tromboembolia/diagnóstico por imagem , Tromboembolia/cirurgia , Adulto , Idoso , Doença Crônica , Feminino , Seguimentos , Humanos , Hipertensão Pulmonar/etiologia , Masculino , Pessoa de Meia-Idade , Tromboembolia/complicações , Resultado do Tratamento
19.
J Am Coll Cardiol ; 39(3): 509-16, 2002 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-11823090

RESUMO

OBJECTIVES: This study was designed to test the feasibility of high-resolution phased-array intracardiac imaging. BACKGROUND: Intracardiac echocardiographic imaging of the heart during interventional electrophysiologic (EP) procedures has been limited by inadequate ultrasound penetration and absence of Doppler hemodynamic and flow information produced by rotating mechanical ultrasound elements. METHODS: A 10F (3.2 mm) phased-array, variable 5.5 to 10 MHz frequency imaging catheter with a four-way deflectable tip was applied in 24 patients undergoing EP studies. Sixteen prespecified cardiac targets were imaged from a right heart venue. RESULTS: Fifteen patients had no underlying organic heart disease; nine had ischemic, cardiomyopathic, valvular or congenital heart disorders. Longitudinal and short-axis imaging readily disclosed each cardiac valve, support structures and chamber, as well as the pericardium, right and left atrial appendages, the junction of the right atrium and superior vena cava, crista terminalis, tricuspid valve isthmus, coronary sinus orifice, membranous fossa ovalis and pulmonary veins. The average target depth was 8.8+/-1.5 cm (range 0.5 to 15 cm), with adequate penetration at a 7.5 MHz imaging frequency. Color flow and Doppler utilities clearly characterized transaortic and pulmonic valve and pulmonary vein blood flow, including during low output states. CONCLUSIONS: These first human studies with this technology demonstrate the methods, feasibility and utility of intracardiac phased-array vector and Doppler imaging for long-axis, apex-to-base global cardiac imaging. High resolution of endocardial structures and catheters suggests additional utility for visualizing interventional procedures from the right heart.


Assuntos
Técnicas Eletrofisiológicas Cardíacas , Ultrassonografia de Intervenção , Ultrassonografia , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/terapia , Vasos Sanguíneos/diagnóstico por imagem , Cateterismo Cardíaco/instrumentação , Cateteres de Demora , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Ultrassonografia/métodos , Ultrassonografia de Intervenção/métodos
20.
J Am Soc Echocardiogr ; 18(3): 252-6, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15746715

RESUMO

The purpose of this study was to provide, in a large number of patients, comprehensive Doppler echocardiographic assessment of normal St Jude Medical mitral valve prosthesis function using Doppler-derived hemodynamic variables, including the mitral valve prosthesis-to-left ventricular outflow tract time-velocity integral ratio and prosthesis performance index. The pressure half-time was less than 130 milliseconds in all patients, and all but one patient had either a peak early mitral diastolic velocity of 2 m/s or less or a mitral valve prosthesis-to-left ventricular outflow tract time-velocity integral ratio of less than 2.2. There was a significant (P < .001) negative correlation between the prosthesis performance index and prosthesis size. This negative correlation suggests that there is more efficient use of the in vitro geometric orifice area with smaller prostheses.


Assuntos
Ecocardiografia Doppler , Próteses Valvulares Cardíacas , Valva Mitral/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Desenho de Prótese , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA