Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Intensive Crit Care Nurs ; : 103778, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39068123

RESUMO

OBJECTIVE: The relationship between ventilator-associated events (VAE) and microaspiration in intubated patients has not be studied. The objective of this study was to evaluate the relationship between abundant microaspiration of oropharyngeal secretions or gastric contents and the incidence of VAE. PATIENTS AND METHODS: This was a post hoc analysis of the BESTCUFF study, which was a multicenter, cluster randomized, cross-over, controlled, open-label trial in adult patients ventilated for over 48 h. All tracheal aspirates were sampled for 48 h following enrollment, with quantitative measurement of pepsin and alpha-amylase. VAE were identified using National Healthcare Safety Network criteria, based on PEEP or FiO2 variations compared to stable parameters in previous days. The primary objective was to assess the relationship between abundant global microaspiration and the incidence of VAE, adjusted for pre-specified confounding factors (sex, SAPS II score and Glasgow coma scale). RESULTS: 261 patients were included, of which 31 (11.9%) developed VAE, with an overall median age of 65 (interquartile range 52-74), a majority of male patients (164, 62.8%), a median SAPS II score of 50 [40-61], a median SOFA score of 8 [5-11], and acute respiratory failure as main reason for ICU admission (117, 44.8%).The incidence of VAE was not significantly associated with abundant global microaspiration (adjusted cause-specific hazard ratio (cHR): 1.55 [0.46-5.17), abundant gastric microaspiration (adjusted cHR: 1.24 [0.61-2.53), or with abundant oropharyngeal microaspiration (adjusted HR: 1.07 [0.47-2.42]). CONCLUSIONS: Our results suggest no significant association between abundant global, gastric or oropharyngeal microaspiration and the incidence of VAE. IMPLICATIONS FOR CLINICAL PRACTICE: This study underscores that measuring microaspiration in intubated critically ill patients might not be useful to predict the diagnosis of VAE or to evaluate interventions aiming at preventing these complications.

2.
Intensive Care Med ; 43(11): 1562-1571, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28303301

RESUMO

PURPOSE: Studies on the impact of tapered-cuff tracheal tubes on rates of microaspiration and ventilator-associated pneumonia (VAP) in intubated patients have reported conflicting results. The aim of this study was to determine the influence of this shape of tracheal cuff on abundant microaspiration of gastric contents in critically ill patients. METHODS: All patients intubated in the intensive care unit (ICU) and requiring mechanical ventilation for at least 48 h were eligible for this multicenter cluster-randomized controlled cross-over open-label study. The primary outcome was abundant microaspiration of gastric contents, defined by the presence of pepsin at significant level in >30% of tracheal aspirates. Quantitative measurement of pepsin and salivary amylase was performed in all tracheal aspirates during the 48 h following enrollment. RESULTS: A total of 326 patients were enrolled in the ten participating ICUs (162 in the PVC tapered-cuff group and 164 in the standard-cuff group). Patient characteristics were similar in the two study groups. The proportion of patients with abundant microaspiration of gastric contents was 53.5% in the tapered-cuff and 51.0% in the standard-cuff group (odds ratio 1.14, 95% CI 0.72-1.82). While abundant microaspiration of oropharyngeal secretions was not significantly different (77.4 vs 68.6%, p = 0.095), the proportion of patients with tracheobronchial colonization was significantly lower (29.6 vs 43.3%, p = 0.01) in the tapered-cuff than in the standard-cuff group. No significant difference between the two groups was found for other secondary outcomes, including ventilator-associated events and VAP. CONCLUSIONS: This trial showed no significant impact of tapered-cuff tracheal tubes on abundant microaspiration of gastric contents. TRIAL REGISTRATION: ClinicalTrials.gov, number NCT01948635.


Assuntos
Intubação Intratraqueal/instrumentação , Pneumonia Associada à Ventilação Mecânica/prevenção & controle , Respiração Artificial/efeitos adversos , Aspiração Respiratória de Conteúdos Gástricos/prevenção & controle , Idoso , Amilases/análise , Biomarcadores/análise , Estudos Cross-Over , Ensaio de Imunoadsorção Enzimática , Desenho de Equipamento , Feminino , Humanos , Unidades de Terapia Intensiva , Intubação Intratraqueal/efeitos adversos , Masculino , Pessoa de Meia-Idade , Pepsina A/análise , Pneumonia Associada à Ventilação Mecânica/diagnóstico , Pneumonia Associada à Ventilação Mecânica/etiologia , Pneumonia Associada à Ventilação Mecânica/microbiologia , Estudos Prospectivos , Aspiração Respiratória de Conteúdos Gástricos/enzimologia , Aspiração Respiratória de Conteúdos Gástricos/etiologia , Aspiração Respiratória de Conteúdos Gástricos/microbiologia
3.
Anaesth Crit Care Pain Med ; 35(2): 93-102, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26603329

RESUMO

OBJECTIVE: The aim of the present study was to determine the use of static and dynamic haemodynamic parameters for predicting fluid responsiveness prior to volume expansion (VE) in intensive care unit (ICU) patients with systemic inflammatory response syndrome (SIRS). METHODS: We conducted a prospective, multicentre, observational study in 6 French ICUs in 2012. ICU physicians were audited concerning their use of static and dynamic haemodynamic parameters before each VE performed in patients with SIRS for 6 consecutive weeks. RESULTS: The median volume of the 566 VEs administered to patients with SIRS was 1000mL [500-1000mL]. Although at least one static or dynamic haemodynamic parameter was measurable before 99% (95% CI, 99%-100%) of VEs, at least one them was used in only 38% (95% CI, 34%-42%) of cases: static parameters in 11% of cases (95% CI, 10%-12%) and dynamic parameters in 32% (95% CI, 30%-34%). Static parameters were never used when uninterpretable. For 15% of VEs (95% CI, 12%-18%), a dynamic parameter was measured in the presence of contraindications. Among dynamic parameters, respiratory variations in arterial pulse pressure (PPV) and passive leg raising (PLR) were measurable and interpretable before 17% and 90% of VEs, respectively. CONCLUSIONS: Haemodynamic parameters are underused for predicting fluid responsiveness in current practice. In contrast to static parameters, dynamic parameters are often incorrectly used in the presence of contraindications. PLR is more frequently valid than PPV for predicting fluid responsiveness in ICU patients.


Assuntos
Cuidados Críticos , Hidratação/métodos , Hemodinâmica , Unidades de Terapia Intensiva , Substitutos do Plasma/uso terapêutico , Pressão Sanguínea , Volume Sanguíneo , Hidratação/normas , França , Estudos Prospectivos , Testes de Função Respiratória
4.
Trials ; 16: 429, 2015 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-26407612

RESUMO

BACKGROUND: Ventilator-associated pneumonia (VAP) is the most common infection in intubated critically ill patients. Microaspiration of the contaminated gastric and oropharyngeal secretions is the main mechanism involved in the pathophysiology of VAP. Tracheal cuff plays an important role in stopping the progression of contaminated secretions into the lower respiratory tract. Previous in vitro studies suggested that conical cuff shape might be helpful in improving tracheal sealing. However, clinical studies found conflicting results. The aim of this study is to determine the impact of conical tracheal cuff shape on the microaspiration of gastric contents in critically ill patients. METHODS/DESIGN: This prospective cluster randomized controlled crossover open-label trial is currently being conducted in ten French intensive care units (ICUs). Patients are allocated to intubation with a polyvinyl chloride (PVC) standard (barrel)-shaped or a PVC conical-shaped tracheal tube. The primary objective is to determine the impact of the conical shaped tracheal cuff on abundant microaspiration of gastric contents. Secondary outcomes include the incidence of microaspiration of oropharyngeal secretions, tracheobronchial colonization, VAP and ventilator-associated events. Abundant microaspiration is defined as the presence of pepsin at significant level (>200 ng/ml) in at least 30 % of the tracheal aspirates. Pepsin and amylase are quantitatively measured in all tracheal aspirates during the 48 h following inclusion. Quantitative tracheal aspirate culture is performed at inclusion and twice weekly. We plan to recruit 312 patients in the participating ICUs. DISCUSSION: BEST Cuff is the first randomized controlled study evaluating the impact of PVC tracheal-cuff shape on gastric microaspirations in patients receiving invasive mechanical ventilation. Enrollment began in June 2014 and is expected to end in October 2015. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT01948635 (registered 31 August 2013).


Assuntos
Tubos Torácicos , Intubação Intratraqueal/instrumentação , Pneumonia Associada à Ventilação Mecânica/prevenção & controle , Respiração Artificial/instrumentação , Aspiração Respiratória de Conteúdos Gástricos/prevenção & controle , Amilases/metabolismo , Técnicas Bacteriológicas , Biomarcadores/metabolismo , Tubos Torácicos/efeitos adversos , Ensaios Enzimáticos Clínicos , Protocolos Clínicos , Estado Terminal , Estudos Cross-Over , Desenho de Equipamento , França , Conteúdo Gastrointestinal/enzimologia , Conteúdo Gastrointestinal/microbiologia , Humanos , Unidades de Terapia Intensiva , Intubação Intratraqueal/efeitos adversos , Pepsina A/metabolismo , Pneumonia Associada à Ventilação Mecânica/diagnóstico , Pneumonia Associada à Ventilação Mecânica/etiologia , Pneumonia Associada à Ventilação Mecânica/microbiologia , Cloreto de Polivinila , Estudos Prospectivos , Projetos de Pesquisa , Respiração Artificial/efeitos adversos , Aspiração Respiratória de Conteúdos Gástricos/diagnóstico , Aspiração Respiratória de Conteúdos Gástricos/etiologia , Aspiração Respiratória de Conteúdos Gástricos/microbiologia , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA