1.
Helicobacter ; 29(1): e13056, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38402559

RESUMO

BACKGROUND AND AIMS: This study aimed to validate Helicobacter pylori serological and pepsinogen (PG) assays for detecting infection and gastric neoplasm. METHODS: Individuals who underwent serum Chorus H. pylori and HBI PG assays were included from May to September 2023. The GastroPanel test was performed using the same blood sample. HBI assay findings were interpreted with the ABC method using the criteria of corpus atrophy (PG I ≤ 70 ng/mL & I/II ≤3) and advanced corpus atrophy (PG I ≤ 30 ng/mL & I/II ≤2). RESULTS: A total of 144 H. pylori-infected and 184 non-infected Koreans were analyzed. The Chorus test (sensitivity 97.2%, specificity 89.1%) showed higher area under the curve (0.993 vs. 0.972, p = 0.003) than the GastroPanel test (sensitivity 95.8%, specificity 86.4%). Using the GastroSoft application, the incidence of gastric neoplasms was highest in the corpus atrophy group (50%), followed by the low acid-output (25.8%), H. pylori infection (11.6%), and antral atrophy (9.1%) groups. There were no gastric neoplasms in the normal and high acid output groups. Using the ABC method, the incidence of gastric neoplasms was highest in the corpus atrophy groups (23.8% in Groups C and D), followed by Group B (12.3%) and Group A (2.4%). Corpus atrophy interpreted with the GastroSoft showed poor agreement (k = 0.225) with corpus atrophy interpreted with the ABC method, whereas it showed excellent agreement (k = 0.854) with advanced corpus atrophy. CONCLUSIONS: Although the Chorus test was more accurate than the GastroPanel test, both assays discriminated high-risk individuals by detecting atrophy or infection. There were no gastric neoplasms in the normal or high acid-output groups (GastroSoft application), and gastric neoplasm incidence was lowest in Group A (ABC method). Corpus atrophy determined by GastroSoft application is more consistent with advanced corpus atrophy determined by the ABC method than is corpus atrophy.


Assuntos
Infecções por Helicobacter , Helicobacter pylori , Neoplasias Gástricas , Humanos , Pepsinogênio A , Estudos Prospectivos , Infecções por Helicobacter/diagnóstico , Atrofia
2.
Clin Chem Lab Med ; 62(5): 958-966, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38000045

RESUMO

OBJECTIVES: White blood cell (WBC)-related flags are essential for detecting abnormal cells including blasts in automated hematology analyzers (AHAs). Cell population data (CPD) may characterize each WBC population, and customized CPD rules can be also useful for detecting blasts. We evaluated the performance of WBC-related flags, customized CPD rules, and their combination for detecting blasts on the Beckman Coulter DxH 900 AHA (DxH 900, Beckman Coulter, Miami, Florida, USA). METHODS: In a total of 239 samples from patients with hematologic diseases, complete blood count on DxH 900 and manual slide review (MSR) were conducted. The sensitivity, specificity, and efficiency of the five WBC-related flags, nine customized CPD rules, and their combination were evaluated for detecting blasts, in comparison with MSR. RESULTS: Blasts were detected by MSR in 40 out of 239 (16.7 %) samples. The combination of flags and CPD rules showed the highest sensitivity compared with each of flags and CPD rules for detecting blasts (97.5 vs. 72.5 % vs. 92.5 %). Compared with any flag, the combination of flags and CPD rules significantly reduced false-negative samples from 11 to one for detecting blasts (27.5 vs. 2.5 %, p=0.002). CONCLUSIONS: This is the first study that evaluated the performance of both flags and CPD rules on DxH 900. The customized CPD rules as well as the combination of flags and CPD rules outperformed WBC-related flags for detecting blasts on DxH 900. The customized CPD rules can play a complementary role for improving the capability of blast detection on DxH 900.


Assuntos
Doenças Hematológicas , Hematologia , Humanos , Contagem de Células Sanguíneas , Doenças Hematológicas/diagnóstico , Leucócitos , Contagem de Leucócitos
3.
Vox Sang ; 117(3): 399-407, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34318939

RESUMO

BACKGROUND AND OBJECTIVES: VISION Max (Ortho Clinical Diagnostics, Raritan, NJ) measures anti-A/B isoagglutinin titres using automated column agglutination technology (CAT). We compared tube test (TT) and CAT of VISION Max comprehensively, including failure mode and effect analysis (FMEA), turnaround time (TAT) and cost, and suggested modified CAT (MCAT). MATERIALS AND METHODS: For 100 samples (each 25 for blood type A, B and O with anti-A and anti-B), anti-A/B isoagglutinin titres were measured by TT and CAT (1:2-1:1024 dilution), as well as by MCAT (with agglutination at 1:32 dilution, then perform additional testing from 1:64 to 1:1024). We assessed the agreement and correlation between TT and CAT and compared FMEA (risk priority number [RPN] score), TAT (h:min:sec) and cost (US dollar, US $) among TT, CAT and MCAT. RESULTS: TT and CAT showed overall substantial agreement (k = 0.73) and high correlation (ρ ≥ 0.75) except blood type O with anti-A (ρ = 0.68). Compared with TT, CAT showed lower RPN scores in FMEA and similar TAT and cost (FMEA, 33,700 vs. 184,300; TAT, 15:23:00 vs. 14:26:40; cost, 1377.4 vs. 1312.4, respectively). Regarding FMEA, TAT and cost, MCAT was superior to CAT or TT (43,810; 13:28:00; 899.2, respectively). CONCLUSION: This is the first multidimensional analysis on VISION Max CAT for measuring anti-A/B isoagglutinin titres. The results of anti-A/B isoagglutinin titres by CAT were comparable with those of TT. MCAT would be a safe, time-saving and cost-effective alternative to TT and CAT in high-volume blood bank laboratories.


Assuntos
Sistema ABO de Grupos Sanguíneos , Hemaglutininas , Aglutinação , Anticorpos , Tecnologia
4.
Clin Chem Lab Med ; 59(6): 1099-1106, 2021 05 26.
Artigo em Inglês | MEDLINE | ID: mdl-33470955

RESUMO

OBJECTIVES: Vision Pro (West Medica, Perchtoldsdorf, Austria) is a recently developed digital morphology analyzer. We evaluated the performance of Vision Pro on white blood cell (WBC) differentials. METHODS: In a total of 200 peripheral blood smear samples (100 normal and 100 abnormal samples), WBC preclassification and reclassification by Vision Pro were evaluated and compared with manual WBC count, according to the Clinical and Laboratory Standards Institute guidelines (H20-A2). RESULTS: The overall sensitivity was high for normal WBCs and nRBCs (80.1-98.0%). The overall specificity and overall efficiency were high for all cell classes (98.1-100.0% and 97.7-99.9%, respectively). The absolute values of mean differences between Vision Pro and manual count ranged from 0.01 to 1.31. In leukopenic samples, those values ranged from 0.09 to 2.01. For normal WBCs, Vision Pro preclassification and manual count showed moderate or high correlations (r=0.52-0.88) except for basophils (r=0.34); after reclassification, the correlation between Vision Pro and manual count was improved (r=0.36-0.90). CONCLUSIONS: This is the first study that evaluated the performance of Vision Pro on WBC differentials. Vision Pro showed reliable analytical performance on WBC differentials with improvement after reclassification. Vision Pro could help improve laboratory workflow.


Assuntos
Leucócitos , Projetos de Pesquisa , Contagem de Células Sanguíneas , Contagem de Leucócitos , Padrões de Referência
5.
J Med Virol ; 92(8): 1040-1046, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31696947

RESUMO

We evaluated the performance of new high-throughput digital lateral flow immunoassays (LFIAs) detecting influenza antigens and compared them with those of the widely used digital LFIA and the rapid nucleic acid amplification test (NAAT). We tested 199 clinical nasopharyngeal (nasal) swab samples using three LFIA tests (BD Veritor Plus, STANDARD F Influenza A/B FIA, and ichroma TRIAS) and the rapid NAAT (ID NOW Influenza A & B2). Agreements and clinical performances (sensitivity and specificity) were evaluated based on the results of reverse transcriptase-polymerase chain reaction (RT-PCR) and verification panel. The agreement of each test with RT-PCR was moderate to almost perfect. The sensitivity of ID NOW was significantly higher than that of LFIAs (P = .0005, .0044, and .0026 for influenza A and P = .0044, .0026, and .0044 for influenza B, respectively). The specificities were not significantly different between the four tests (P > .05). However, the reference panel suggests that ichroma TRIAS test is more sensitive than the other two LFIA tests. All three LFIA assays performed similarly with no false positives against influenza A. For influenza B, ichroma TRIAS had 2 of 166 false positives whereas there were no false positives for the other two LFIA tests. Influenza antigen digital LFIAs have advantages in terms of the workflow when simultaneous tests are required. Rapid NAAT has higher sensitivity, while new antigen LFIAs are efficient and high-throughput. It is recommended that users select appropriate methods and algorithms according to the number of specimens and laboratory conditions in each clinical laboratory.


Assuntos
Antígenos Virais/análise , Imunoensaio/métodos , Vírus da Influenza A/isolamento & purificação , Vírus da Influenza B/isolamento & purificação , Influenza Humana/diagnóstico , Nasofaringe/virologia , Reações Falso-Positivas , Humanos , Vírus da Influenza A/imunologia , Vírus da Influenza B/imunologia , Influenza Humana/virologia , Técnicas de Amplificação de Ácido Nucleico , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Sensibilidade e Especificidade , Manejo de Espécimes
6.
Clin Oral Investig ; 23(3): 1415-1423, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30032469

RESUMO

OBJECTIVES: The aim of this study was to investigate the diagnostic accuracy of rheumatoid factor (RF) isotype for the detection of primary Sjogren's syndrome (pSS) and evaluate the clinical and serological associations of immunoglobulin (Ig) A RF in patients with pSS. MATERIALS AND METHODS: RF levels were measured in 77 and 37 patients with pSS and idiopathic sicca symptoms, respectively, using ELISA and analysed with respect to clinical and laboratory disease characteristics. Receiver operating characteristic curves were used to determine and compare the diagnostic accuracy of IgA RF with other diagnostic tests. RESULTS: Serum levels of IgA RF were significantly higher in patients with pSS than in those with idiopathic sicca symptoms. IgA RF showed sensitivity, specificity, positive, and negative predictive values of 83.1, 78.4, 88.9, and 69.0%, respectively, for pSS diagnosis. IgA RF was associated with xerostomia, severe sialoscintigraphic grade, low unstimulated salivary flow rate (USFR), antinuclear antibody, high IgG and IgM/G RF levels, and low C3 levels in patients with pSS. IgA RF titres had positive correlations with sialoscintigraphic grade and IgG and IgG/M RF levels and had negative correlations with USFR and C3 levels. CONCLUSION: Our findings confirmed the potential of IgA RF to distinguish pSS from idiopathic sicca symptoms. The presence of IgA RF in patients with pSS was associated with significantly worse exocrine function and active serologic profile. No association between IgA RF and extra-glandular manifestations was noted. CLINICAL RELEVANCE: IgA RF should be the predictive and diagnostic marker in patients with pSS.


Assuntos
Imunoglobulina A/sangue , Fator Reumatoide/sangue , Síndrome de Sjogren/diagnóstico , Idoso , Anticorpos Antinucleares/sangue , Feminino , Humanos , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Síndrome de Sjogren/sangue
7.
Infection ; 46(1): 113-117, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29218569

RESUMO

PURPOSE: This study aimed to evaluate the clinical significance of toxin positivity and toxin gene load, and the relation between them in the broad spectrum of Clostridium difficile infection (CDI) including colonization, significant diarrhea, and severe disease. METHODS: We included 2671 fecal samples submitted for CDI diagnosis and 180 samples from healthy individuals. The clinical spectrum was categorized as category I (toxigenic C. difficile positive without clinical CDI criteria), category II (mild CDI), and category III (severe CDI). Clinical parameters were compared based on toxin EIA and tcdB C t values. C t values of tcdB PCR for predicting toxin EIA positivity were assessed using receiver-operating characteristic (ROC) curves. RESULTS: The median C t values of tcdB PCR and toxin positivity were not significantly correlated with clinical spectrum of CDI (27.5, 28.2, and 26.1 for tcdB C t and 55.0, 56.6, and 60.9% for toxin EIA positivity in category I, II, and III, respectively, P > 0.05). There were significant differences in the tcdB C t values between toxin EIA-positive and -negative groups (P < 0.001). Optimal cutoff for the tcdB C t value for estimating toxin EIA positivity was 26.3 with 79.3% sensitivity and 83.6% specificity with good area under the curves (AUC, 0.848). CONCLUSIONS: The C t values successfully predicted toxin EIA positivity and could be used as a surrogate for toxin EIA positivity in the diagnostic algorithm and routine analysis. Further studies are needed to validate the clinical significance of tcdB PCR C t value in toxigenic C. difficile colonization and infection.


Assuntos
Proteínas de Bactérias/genética , Toxinas Bacterianas/genética , Clostridioides difficile/fisiologia , Infecções por Clostridium/microbiologia , Diarreia/microbiologia , Carga Genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Proteínas de Bactérias/metabolismo , Toxinas Bacterianas/metabolismo , Clostridioides difficile/genética , Fezes/microbiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
8.
J Gastroenterol Hepatol ; 33(7): 1370-1378, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29232004

RESUMO

BACKGROUND AND AIM: Naturally occurring hepatitis B virus variants carrying a deletion in the preS1 start codon region may evolve during long-lasting virus-host interactions in chronic hepatitis B (CHB). The aim of this study was to determine the immune phase-specific prevalent patterns of preS1 start codon deletion variants and related factors during the natural course of CHB. METHODS: A total of 399 CHB patients were enrolled. Genotypic analysis of three different preS1 start codon deletion variants (classified by deletion size: 15-base pair [bp], 18-bp, and 21-bp deletion variants) was performed. RESULTS: PreS1 start codon deletion variants were detected in 155 of 399 patients (38.8%). The predominant variant was a 15-bp deletion in the immune-tolerance phase (18/50, 36%) and an 18-bp deletion in the immune-clearance phase (69/183, 37.7%). A 21-bp deletion was the predominant variant in the low replicative phase (3/25, 12.0%) and reactivated hepatitis Be antigen (HBeAg)-negative phase (22/141, 15.6%). The 15-bp and 18-bp deletion variants were more frequently found in HBeAg-positive patients (P < 0.010 and P < 0.001, respectively), whereas the 21-bp deletion variant was more frequently found in HBeAg-negative patients (P < 0.001). On multiple logistic regression analyses, the 21-bp deletion variant was independently associated with liver cirrhosis (P = 0.006), and the 15-bp deletion variant was significantly related to an incomplete response to antiviral agents (P = 0.012). CONCLUSIONS: The predominant type of preS1 start codon deletion variants changes according to the immune phases of CHB infection, and each variant type is associated with different clinical parameters. PreS1 start codon deletion variants might interact with the host immune response differently according to their variant types.


Assuntos
Códon/genética , Deleção de Genes , Variação Genética , Antígenos de Superfície da Hepatite B/genética , Vírus da Hepatite B/genética , Hepatite B Crônica/virologia , Interações Hospedeiro-Patógeno/genética , Precursores de Proteínas/genética , Adulto , Antivirais , Feminino , Técnicas de Genotipagem , Hepatite B Crônica/imunologia , Humanos , Cirrose Hepática/genética , Cirrose Hepática/virologia , Modelos Logísticos , Masculino , Pessoa de Meia-Idade
9.
Scand J Clin Lab Invest ; 78(6): 477-482, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30073867

RESUMO

Anti-cyclic citrullinated peptide antibodies (anti-CCPs) are important diagnostic markers for rheumatoid arthritis (RA). We evaluated the analytical and clinical performance of the QUANTA Flash CCP3 (INOVA Diagnostics, USA), a fully automated third-generation anti-CCP assay, in comparison with three second-generation anti-CCP (CCP2) assays. A total of 300 sera (67 from RA patients, 64 from other rheumatic diseases, 43 from osteoarthritis [OA], and 126 from other conditions) were tested with QUANTA Flash CCP3, Kallestad Anti-CCP II (Bio-Rad, USA), Elecsys Anti-CCP (Roche Diagnostics GmbH, Germany), and ARCHITECT Anti-CCP (Abbott Diagnostics, USA). Within-run and total imprecision (% coefficient of variation) of the QUANTA Flash CCP3 were <6%, and its linearity was acceptable over the claimed range (4.0-2,749.7 chemiluminescent units). The frequency of anti-CCP was similar between QUANTA Flash CCP3 and the other CCP2 assays in the RA (67.2% vs. 62.7-70.1%), other rheumatic diseases (7.8% vs. 6.3%), and OA (2.3% vs. 0-2.3%) groups. The concordance rate between QUANTA Flash CCP3 and the other assays ranged from 96.3% to 97.7% (kappa from 0.87 to 0.92). For the diagnosis of RA, the sensitivity/specificity was 67.2%/95.7%, 62.7%/98.3%, 70.2%/96.6%, and 67.2%/97.9%, and the areas under the receiver operating characteristic curves were 0.851, 0.791, 0.853, and 0.867 for QUANTA Flash CCP3, Kallestad, Elecsys, and ARCHITECT assays, respectively. The performance of the QUANTA Flash CCP3 was satisfactory and comparable to that of the three CCP2 assays. This fully automated assay would be a practical and reasonable option in clinical laboratories.


Assuntos
Anticorpos Antiproteína Citrulinada/sangue , Artrite Reumatoide/diagnóstico , Automação Laboratorial/normas , Imunoensaio/normas , Osteoartrite/diagnóstico , Adulto , Idoso , Artrite Reumatoide/sangue , Artrite Reumatoide/imunologia , Artrite Reumatoide/patologia , Biomarcadores/sangue , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite/sangue , Osteoartrite/imunologia , Osteoartrite/patologia , Curva ROC
10.
J Clin Microbiol ; 55(6): 1650-1657, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28298455

RESUMO

Although launched in 2015, little is known about the accuracy of QuantiFERON-TB Gold-Plus (QFT-Plus) for diagnosis of latent M. tuberculosis infection (LTBI). Unlike its predecessor, QFT-Plus utilizes two antigen tubes to elicit an immune response from CD4+ and CD8+ T lymphocytes. We conducted a cross-sectional study in low-risk health care workers (HCWs) at a single U.S. center to compare QFT-Plus to QuantiFERON-TB Gold in-tube (QFT). A total of 989 HCWs were tested with both QFT and QFT-Plus. Risk factors for LTBI were obtained from a questionnaire. QFT-Plus was considered positive if either antigen tube 1 (TB1) or TB2 tested positive, per the manufacturer's recommendations, or if both TB1 and TB2 tested positive, using a conservative definition. Results were compared using Cohen's kappa and linear regression, respectively. Agreement of QFT with QFT-Plus was high, at 95.6% (95% confidence interval [CI], 94.3 to 96.9; kappa, 0.57). The majority of discordant results between QFT and QFT-Plus TB1 (84.8%) and QFT and QFT-Plus TB2 (88.6%) fell within the range of 0.2 to 0.7 IU/ml. The positivity rate in 626 HCWs with no identifiable risk factors and no self-reported history of positive LTBI tests was 2.1% (CI, 1.0 to 3.2) and 3.0% (CI, 1.7 to 4.3) with QFT and QFT-Plus, respectively. A conservative definition of a QFT-Plus-positive result yielded a positivity rate of 1.0% (CI, 0.2 to 1.7; P value of 0.0002 versus QFT-Plus and 0.07 versus QFT). On follow-up testing, of 11 HCWs with discordant QFT-Plus results, 90.9% (10/11) had a negative QFT result. The QFT-Plus assay showed a high degree of agreement with QFT in U.S. HCWs. A conservative interpretation of QFT-Plus eliminated nearly all nonreproducible positive results in low-risk HCWs. Larger studies are needed to validate the latter finding and to more clearly define conditions under which a conservative interpretation can be used to minimize nonreproducible positive results in low-risk populations.


Assuntos
Testes Diagnósticos de Rotina/métodos , Pessoal de Saúde , Testes de Liberação de Interferon-gama/métodos , Tuberculose Latente/diagnóstico , Adulto , Estudos Transversais , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Estados Unidos
11.
Clin Chem Lab Med ; 56(1): 94-102, 2017 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-28672770

RESUMO

BACKGROUND: The Sysmex DI-60 system (DI-60, Sysmex, Kobe, Japan) is a new automated digital cell imaging analyzer. We explored the performance of DI-60 in comparison with Sysmex XN analyzer (XN, Sysmex) and manual count. METHODS: In a total of 276 samples (176 abnormal and 100 normal samples), white blood cell (WBC) differentials, red blood cell (RBC) classification and platelet (PLT) estimation by DI-60 were compared with the results by XN and/or manual count. RBC morphology between pre-classification and verification was compared according to the ICSH grading criteria. The manual count was performed according to the Clinical and Laboratory Standards Institute guidelines (H20-A2). RESULTS: The overall concordance between DI-60 and manual count for WBCs was 86.0%. The agreement between DI-60 pre-classification and verification was excellent (weighted κ=0.963) for WBC five-part differentials. The correlation with manual count was very strong for neutrophils (r=0.955), lymphocytes (r=0.871), immature granulocytes (r=0.820), and blasts (r=0.879). RBC grading showed notable differences between DI-60 and manual counting on the basis of the ICSH grading criteria. Platelet count by DI-60 highly correlated with that by XN (r=0.945). However, DI-60 underestimated platelet counts in samples with marked thrombocytosis. CONCLUSIONS: The performance of DI-60 for WBC differential, RBC classification, and platelet estimation seems to be acceptable even in abnormal samples with improvement after verification. DI-60 would help optimize the workflow in hematology laboratory with reduced manual workload.


Assuntos
Automação , Testes Hematológicos , Contagem de Células Sanguíneas , Eritrócitos/citologia , Testes Hematológicos/instrumentação , Humanos , Leucócitos/citologia , Linfócitos/citologia
12.
Helicobacter ; 20(1): 49-55, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25257099

RESUMO

BACKGROUND: The correlation between allergic disease and Helicobacter pylori infection is still controversial in endemic areas. The aim of this study was to determine whether H. pylori infection is related to allergic disease and/or immunoglobulin E (IgE) hypersensitivity in Korean adults. MATERIALS AND METHODS: Consecutive Korean adults who visited our center for a routine checkup were enrolled. All subjects completed a questionnaire that was designed to ascertain their medical history pertaining to physician-diagnosed allergic disease, allergy treatments, and H. pylori eradication therapy. Blood was sampled for serum anti-H. pylori IgG antibody. IgE hypersensitivity was measured using a commercially available ImmunoCAP(®) Phadiatop (Phadia AB, Uppsala, Sweden). RESULTS: Of the 3376 Korean adults who were enrolled, 62 did not answer to the questionnaires adequately and were thus excluded. The proportion of noninfected subjects (p < .001) and the prevalence of IgE-related allergic disease (p < .001) were both highest among those aged <40 years, while the prevalence of non-IgE-related allergic disease was highest among those aged ≥70 years (p < .001). Logistic regression analysis revealed that being younger than 40 years was significantly related to the absence of H. pylori infection (OR = 2.507, 95% CI = 1.621-3.878, p < .001). CONCLUSIONS: The statuses of H. pylori infection, IgE hypersensitivity, and allergic diseases differ with age group, there being a higher prevalence of IgE-related allergic disease and a lower H. pylori infection rate among young adults. The hygiene hypothesis might explain these findings in young Koreans, due to the rapid development and improvements in sanitation in Korea.


Assuntos
Infecções por Helicobacter/complicações , Hipersensibilidade/epidemiologia , Imunoglobulina E/sangue , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Povo Asiático , Estudos Transversais , Feminino , Humanos , Coreia (Geográfico)/epidemiologia , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Adulto Jovem
14.
Clin Chem Lab Med ; 53(7): 1091-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25460288

RESUMO

BACKGROUND: Recently introduced hematology analyzer, the Sysmex XN modular system (Sysmex, Kobe, Japan), has newly adopted a florescent channel to detect platelets and immature platelet fraction (IPF). This study aimed to establish new reference intervals for %-IPF and absolute number of IPF (A-IPF) on Sysmex XN. Platelet counts, %-IPF, and A-IPF were also compared between Sysmex XN and XE-2100 systems (Sysmex). METHODS: Except outliers, blood samples from 2104 healthy individuals and 140 umbilical cord blood were analyzed using both Sysmex XN and XE-2100. The results of two systems were compared using Bland-Altman plot. The reference intervals for %-IPF and A-IPF were defined using non-parametric percentile methods according to the Clinical and Laboratory Standard Institute guideline (C28-A3). RESULTS: The platelet counts, %-IPF, and A-IPF showed non-parametric distributions. The mean difference between Sysmex XN and XE-2100 in healthy individuals revealed a positive bias in platelets (+8.0×109/L), %-IPF (+1.2%), and A-IPF (+3.0×109/L). The reference intervals for %-IPF and A-IPF on Sysmex XN were: 1.0%-7.3% and 2.49-15.64×109/L in healthy individuals; and 1.0%-4.4% and 2.94-12.82×109/L in umbilical cord blood. CONCLUSIONS: This large-scale study demonstrates a clear difference of platelet counts and IPF between Sysmex XN and XE-2100. The new reference intervals for IPF on Sysmex XN would provide fundamental data for clinical practice and future research.


Assuntos
Plaquetas/citologia , Contagem de Plaquetas/normas , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Contagem de Plaquetas/instrumentação , Valores de Referência , Adulto Jovem
15.
J Clin Lab Anal ; 29(2): 142-5, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24797357

RESUMO

BACKGROUND: Rifampin (RIF) is the most important first-line antituberculosis drug, and resistance to this drug may result in treatment failures. We evaluated the diagnostic performances of recently introduced, molecular assays for the detection of RIF resistance. METHODS: A total of 100 isolates (50 RIF resistant and 50 RIF susceptible) were studied. Their RIF resistances were determined by conventional drug-susceptibility test. These results were compared with those of three molecular assays: Xpert MTB/RIF assay (MTB is Mycobacterium tuberculosis), Sacace MTB Real-TM resistance, and AdvanSure MDR-TB GenoBlot assay (MDR is multidrug resisitant). RESULTS: Sensitivities for RIF resistance detection of Xpert MTB/RIF assay, Sacace MTB Real-TM resistance, and Advansure GenoBlot assay were 94.0%, 91.8%, and 84.0%, respectively. Their specificities for RIF resistance detection were all 100%. CONCLUSION: Three molecular assays for the detection of RIF resistance have various performances. Xpert MTB/RIF assay shows the highest sensitivity among the three molecular assays and can be an effective choice in clinical laboratories.


Assuntos
Farmacorresistência Bacteriana/genética , Mycobacterium tuberculosis/efeitos dos fármacos , Rifampina/farmacologia , Proteínas de Bactérias/genética , Catalase/genética , RNA Polimerases Dirigidas por DNA , Humanos , Testes de Sensibilidade Microbiana , Mutação , Mycobacterium tuberculosis/genética , Oxirredutases/genética , Reação em Cadeia da Polimerase , Tuberculose Resistente a Múltiplos Medicamentos/microbiologia
16.
Clin Chem Lab Med ; 52(12): 1771-9, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24978899

RESUMO

BACKGROUND: The Sysmex XN (XN) modular system (Sysmex, Kobe, Japan) is a new automated hematology analyzer equipped with different principles from its previous version, Sysmex XE-2100. We compared the performances of Sysmex XN and XE-2100 in umbilical cord blood (CB) specimens. METHODS: In 160 CB specimens, complete blood count (CBC) parameters and white blood cells (WBC) differentials were compared between the two analyzers. Their flagging performances for blasts, abnormal/atypical lymphocytes, immature granulocytes and/or left-shift (IG), and nucleated red blood cells (NRBC) counts were compared with manual counts. For the blast flagging, Q values by Sysmex XN were further compared with manual slide review. RESULTS: Sysmex XN and XE-2100 showed high or very high correlations for most CBC parameters but variable correlations for WBC differentials. Compared with XE-2100, XN showed significantly different flagging performances for blasts, abnormal/atypical lymphocytes, and IG. The flagging efficiency for blasts was significantly better on Sysmex XN than on XE-2100 (85.0% vs. 38.8%): Sysmex XN showed a remarkably increased specificity of blast flag, compromising its sensitivity of blast flag. Among the 24 specimens with blasts (range, 0.5%-1.5%), only one (4.2%) showed a positive Q value. CONCLUSIONS: This study highlighted the remarkable differences of flagging performances between Sysmex XN and XE-2100 in CB specimens. The Sysmex XN modular system seems to be a suitable and practical option for the CB specimens used for hematopoietic stem cell transplantation as well as for the specimens from neonates.


Assuntos
Contagem de Células Sanguíneas/métodos , Sangue Fetal/citologia , Adulto , Peso ao Nascer , Contagem de Células Sanguíneas/instrumentação , Feminino , Idade Gestacional , Humanos , Recém-Nascido , Leucócitos/citologia , Linfócitos/citologia , Pessoa de Meia-Idade , Adulto Jovem
18.
Diagnostics (Basel) ; 14(2)2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38275478

RESUMO

We evaluated the diagnostic performance of the STANDARD i-Q COVID-19 Ag Test, which was developed to detect viral antigens, using nasal and oral swabs. Sixty positive and 100 negative samples were analyzed. We determined the distribution of the Ct values according to the day of sample collection after symptom onset, the diagnostic performance of the total samples and subgroups separated by Ct value or time of sample collection, and the Ct value at which maximal accuracy was expected. No differences were observed in Ct values, except for the samples obtained on the day of symptom onset. The diagnostic sensitivity and specificity of the oral swabs were 75.0 and 100.0%, respectively, whereas those of the nasal swabs were 85.0 and 98.0%, respectively. The sensitivity was higher in samples with a high viral load collected earlier than those collected later, although the difference was not significant. False-negative results were confirmed in all samples with a Ct value ≥ 30.0. These results indicate that tests using oral and nasal swabs are helpful for diagnosing acute symptomatic cases with suspected high viral loads. Our tests exhibited relatively low sensitivity but high specificity rates, indicating the need to assess negative antigen test results.